Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Similar documents
Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

VSA. Roof fans. Dachventilatoren. Roof fans

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VSA. Roof fans. Tourelles. Dachventilatoren. Крышные вентиляторы. Roof fans

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

NEW! Mounting clamp Guard grille Back draft shutter Circular duct silencer

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

KV sileo 100 M. Circular duct fans. Circular duct fans

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

Single-inlet centrifugal fans

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

VORTICENT C E RANGE Centrifugal fans

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

AC Commercial Fans Edition. ErP ready

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Wall mounted fan

CYLINDRICAL CASED AXIAL FLOW FANS

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Short casing. Long casing (L version) Commercial premises

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

FEATURES & BENEFITS UPON REQUEST

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Mixed Flow Roof Fans (RMH)

ROOFMASTER STEF-HT ROOF FAN

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CMR/EW EFFICIENT WORK

Performance. Sound Levels. Impellers. Motors. Accessories

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

Sabre Plate Mounted Sickle Fans (VSP)

Uniclass L7534. Manufacture controlled to ISO9001

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Mixed Flow Roof Fans (RMH)

CENTRIFUGAL IN-LINE FANS VENT Series

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

VSV/VSVI. Roof fans. Tourelles. Dachventilatoren. Tagventilatorer VSV VSVI ROOF FANS

NEW Acoustic In-Line Fans (ACQ)

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

NEW Slimpak EC Box Fan (SLPT EC)

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

Sentinel D-Box Single Fan

ROOFMASTER STEF ROOF FAN

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BOX BLB Centrifugal Box Fan

Square Mixed Flow Fans (MFQ)

Sentinel D-Box Twin Fan

NCF fans 50 Hz. Protection class IP 55

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CMP/EW EFFICIENT WORK

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

TGT Series Adjustable Pitch Fans

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Centriflow Plus EC. Technical data

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

ACOUSTIC CABINET FANS CVAB / CVAT Series

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Inside Front cover White

ROOF FAN ROOFMASTER STEC

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

CGT Series Adjustable Pitch Fans

ROOFMASTER STEF-ATEX ROOF FAN

In-line rectangular fans. Technical Catalogue

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

Transcription:

VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22 S, 22 M, 225, 25. onstruction Installation Speed control options asing: powder-coated steel, RA 95; Motor protected from external objects; Fan: centrifugal impeller and external rotor motor; Motor protection with built-in thermal contact; Motor protection class: IP44; Terminal box protection class: IP55. Device can be connected to pull air directly from ventilated room or air duct system. ot suitable for polluted air or volatile and explosive gases. Electronic voltage controller (phase cut); Voltage controlled speed controller. VSA 19 S 3. Version Motor power level (S low, M medium, high). ominal impeller diameter Product name Accessories Single phase speed controller Single phase speed controller urb skirt urb skirt Roof curb Flange-adapter TGRV p. 127 ETY p. 128 SSA p. 138 SSA 45 p. 138 KSV p. 132 FSV p. 137 96

VSA 3. Type Dimensions [mm] ød H h ød ød1 m m1 n VSA 19 S 3. 344 27 17 35 177 M4 96,5 123,5 245 VSA 19 3. 344 27 17 35 177 M4 96,5 123,5 245 VSA 22 S 3. 45 214,35 19 45 23 M5 138 168 33 VSA 22 M 3. 45 214,35 19 45 23 M5 138 168 33 VSA 225 3. 45 245,55 19 45 23 M5 138 168 33 VSA 25 3. 45 245,55 19 45 23 M5 138 168 33 ROOF FAS Type Accessories TGRV ETY SSA SSA 45 KSV FSV ATS SV VSA 19 S 3. 1,5 1,5 3 3 3/6 16 19 16 VSA 19 3. 1,5 1,5 3 3 3/8 3/9 16 19 16 VSA 22 S 3. 1,5 1,5 4 4 25 25 25 4/6 VSA 22 M 3. 1,5 1,5 4 4 4/8 25 25 25 VSA 225 3. 1,5 1,5 4 4 4/9 25 25 25 4/1 VSA 25 3. 1,5 1,5 4 4 25 25 25 Back draft shutter Flexible connection ATS p. 135 SV p. 136 97

VSA 3. VSA 19 S 3. 8 7 8V 12V 14V 6 17V 5 4 23V 3 2 1 19 S 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 61 43 5 53 57 54 48 41 Outlet 62 42 56 52 56 56 51 43 Surrounding 59 44 53 51 53 51 48 38 Measured at 236 m 3 /h, 82 Pa VSA 19 3. ROOF FAS 2 18 16 8V 12V 14V 14 12 1 17V 23V 8 6 4 2 19 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 66 44 55 59 6 61 57 43 Outlet 69 45 6 62 65 6 56 44 Surrounding 61 38 52 54 58 54 48 34 Measured at 299 m 3 /h, 152 Pa VSA 19 S 3. VSA 19 3. Voltage/Frequency [V/Hz] 23/5 23/5 [kw],49,74 urrent [A],2,31 Speed [min -1 ] 275 28 apacitor [µf] 4 2 Max. airflow [m 3 /h] 36 456 Min.\Max. air temperature [ ] -4\55-4\55 Weight [kg] 4,4 4,4 Wiring diagram o. 2 o. 1 Protection class: motor IP-44 IP-44 terminal box IP-54 IP-54 omply with ERP 216 216 98 The fan characteristic curves were determined in accordance with E ISO 581. The sound levels were determined in accordance with DI 45635 resp. ISO 3744 at a distance of 1 m from the fan.

VSA 3. VSA 22 S 3. 14 8V 12V 12 14V 1 17V 8 23V 6 4 2 22 S 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 67 48 54 61 62 59 56 53 Outlet 68 5 58 63 63 6 55 47 Surrounding 6 43 51 54 56 51 47 39 Measured at 299 m 3 /h, 114 Pa VSA 22 M 3. 2 18 16 8V 12V 14V ROOF FAS 14 12 1 17V 23V 8 6 4 2 22 M 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 71 56 58 66 65 63 61 57 Outlet 71 53 63 64 66 62 6 54 Surrounding 65 48 55 58 62 57 53 46 Measured at 556 m 3 /h, 182 Pa VSA 225 3. 3 25 8V 12V 14V 2 17V 15 23V 1 5 225 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 69 52 57 63 65 63 56 52 Outlet 72 51 59 66 68 66 62 53 Surrounding 66 45 54 57 62 6 54 48 Measured at 594 m 3 /h, 273 Pa The fan characteristic curves were determined in accordance with E ISO 581. The sound levels were determined in accordance with DI 45635 resp. ISO 3744 at a distance of 1 m from the fan. 99

VSA 3. VSA 25 3. 35 3 25 8V 12V 14V 17V 2 23V 15 1 5 25 3. wa total, wa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 71 58 6 64 66 64 63 58 Outlet 74 6 64 66 7 68 62 55 Surrounding 67 53 56 6 62 6 55 47 Measured at 848 m 3 /h, 253 Pa ROOF FAS VSA 22 S 3. VSA 22 M 3. VSA 225 3. VSA 25 3. Voltage/Frequency [V/Hz] 23/5 23/5 23/5 23/5 [kw],67,16,133,221 urrent [A],28,45,6,94 Speed [min -1 ] 26 28 266 27 apacitor [µf] 4, 2, 4, 5, Max. airflow [m 3 /h] 636 795 95 117 Min.\Max. air temperature [ ] -4\75-4\75-4/85-4\7 Weight [kg] 6,7 6,7 7,6 7,9 Wiring diagram o. 2 o. 1 o. 1 o. 1 Protection class: motor IP-44 IP-44 IP-44 IP-44 terminal box IP-54 IP-54 IP-54 IP-54 omply with ERP 216 218 218 218 YE/G B BU Wiring diagram o. 1 YE/G - green-yellow - black - red BU - blue B - brown YE/G B SP2--k YE/G Wiring diagram o. 2 YE/G - green-yellow B - black - red BU - blue B - brown SP2--k YE/G B 1 Protective earth, 1, - line voltage 23V YE/G - yellow/green; - black, - red; B - braun; BU - blue, Protective earth, 1, - line voltage 23V YE/G - yellow/green; - b - red; B - braun; BU - blu