Operating Instructions type Always on the safe side.

Similar documents
Operating Instructions K Always on the safe side.

Operating instructions K- Control 4960, 4965, Always on the safe side.

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Operating Instructions

Installation manual portable distributors

Katalysator Nr /

Installation manual wall-mounted distributor

Operating Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Operating Instruction K-Control TLC 4955, 4956, Always be on the safe side.

Type 6213 EV, 6281 EV

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Mounting and Operating Manual Non-Return valves Swing-Check valves

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

HST-BL-2830MS & HST-BL-2830MS-USA

Operating Instructions

Demco. Model E Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Инструкция по эксплуатации

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Instruction Manual. Ex-Time 40 / 50

basic quattro No /

3. Operating instructions: Minor 200

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Megohmmeter Test Probe

These installation and maintenance instructions must be read in full and completely understood before the installation!

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

28W WORK LAMP Model: CTL28 Part No:

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Operating Instructions (Translation)

Printed: Doc-Nr: PUB / / 000 / 00

7 Lighting Technology

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Linear Luminaire for Fluorescent Lamps

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

US - UP2/OIL 12V US - UP2/OIL 24V

Instructions for use. PHYSIO Evo/Evo F/One

Instructions for use K-ERGOgrip Always on the safe side.

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Level Measuring Sensor for Diesel Fuel Tanks

Operating instructions Accu Jet

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Armon Edero. User manual

HEINE NT4 MED V

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Contamination switch VS

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

OPERATING INSTRUCTIONS

JET 2000 Modell S42 EN

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

HST -LS Interlocking device (Translation of Original Manual)

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Wilo-Control SC-Fire Jockey

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

Linear Luminaire with LED

Switching DC Power Supply

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Register your instrument! HeatSealer S100. Operating manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

PURE SINE WAVE DC TO AC POWER INVERTER

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Assembly and Operating Instructions

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MANUAL. Single charger

Oil-free piston compressors KK and piston vacuum pumps KV

DeltaSol AX * *

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

BODAS Pressure sensor PR3 series 10

KEWTECH. KT56 digital multi function tester. Instruction manual

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Angle Sensor WS1. RE Edition: Replaces:

User s Manual Power Supply IM E. 5th Edition

Assembly and Maintenance Manual Type ASNU

Solenoid Operator 0516 / 1216

ZB0050 / ZB0051 ZB0070 / ZB0071

Operating Instructions (Translation of the original operating instructions) Leister TAPEMAT Hot-Air welding machine

Service information. How to avoid equipment failures with preventive maintenance measures. 1. General information 08/2017

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

WK 120QMM-6M/Z EL 120QMM-6M/M12

Ex m Solenoid Operator Type 0519

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Installation and Connection: Installation and Operating Manual

Solenoid Operator 0513 / 1213

Model G14SD Vapor Management System

English. Instruction and operation manual S 212. Dew point sensor

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Operating instructions ErgoPack 600 E

User's Manual. Battery Pack. powerpackpoint

Transcription:

Operating Instructions type 5220. Always on the safe side.

KaVo Elektrotechnisches Werk GmbH Wangener Straße 78 D-88299 Leutkirch Tel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-265

A 1 User notes...2 A 1.1 Meaning of the pictograms...2 A 1.2 Important information...2 A 1.3 Safety measures...2 A 1.4 Uses and applications...3 A 1.5 Cleaning and care of the unit...3 A 2 Installation...4 A 3 Electrical connection...4 A 4 Setting up...5 A 4.1 Turning the jointed arm...5 A 4.2 Adjusting the hinge-joints...5 A 5 Operation...5 A 6 Maintenance, repair and disposal...6 A 6.1 Changing a fluorescent tube...6 A 6.2 Disposal...6 A 7 Operating faults...7 A 8 Technical data...8 Guarantee conditions...9 Spare parts...10 EC- Declaration of conformity...11 1

A 1 User notes A 1.1 Meaning of the pictograms Situation which can lead to danger, damage to materials or operating faults if the information is ignored. Important information for operators and technicians. Automatic mode Automatic sequence Close, screw in, fasten, etc. Open, release, loosen + more, higher - less, lower Continuous operation Time, time sequence Disconnect mains plug A 1.2 Important information The operating instructions should be read by the user before putting the unit into operation for the first time, in order to avoid incorrect operation and damage. If further language versions are required, please request these from your responsible KaVo agent. Duplication and distribution of the Operating Instructions (OI) require prior consent from KaVo. All technical data, information and properties of the unit described in these OI instructions correspond to the situation on going to press. Modifications and improvements to the product on the basis of technical innovations are possible. This does not imply any right to upgrading of existing units. KaVo assumes no responsibility for damage arising through: external influences (poor quality of the media or poor installation) use of incorrect information improper use improperly performed repairs. The following are authorized to repair and service KaVo products: the engineers of the KaVo agents throughout the world the engineers of the KaVo dealers who have been specially trained by KaVo independent engineers specially trained by KaVo. In the event of modifications by third parties, the approvals become null and void. KaVo recommends using only original spare parts for operation and for repairs A 1.3 Safety measures Safe operation and protection of the product is only assured by proper usage according to the Operating Instructions and by using the approved tools. Additionally, the following are to be observed: Safety at Work Regulations Prevention of Accidents Regulations In accordance with these requirements, it is the duty of the user: to use only flawless materials to observe the correct applications to protect the patient, and others, from injury to avoid contamination by the product not to operate the unit if functional parts are damaged. The light must be operated in dry rooms, free from danger of explosion! With lights of Protection Class 1, it is absolutely essential that the earth wire is connected to the light housing. Failure to observe this could lead to danger of electric shock! 2

A 1.4 Uses and applications The workplace light(s) are designed for individual place lighting and, according to DIN 5035 Part 1, are to be used in addition to the overall illumination. Location: Only in dry rooms, free from risk of explosion. Type of operation: The light is designed for continuous operation. Any other use or type of application is considered to be outside the proper useage. KaVo assumes no liability for any resulting damages. Proper useage includes also: Observing all recommendations in the operating instructions, and Carrying out the maintenance procedures. A 1.5 Cleaning and care of the unit Regular cleaning of the transparent diffuser ensures a continuing high level of the light output. Use a cloth soaked in normal household cleanser for cleaning of the component parts. Ensure that the cleanser to be used has no adverse reactions on painted or plastic surfaces. Under no circumstances must concentrated disinfectants or solvent materials such as, for example, Sagrotan, Lysoform, Ethylalcohol or other liquids containing alcohol be used for cleaning. The manufacturer assumes no liability for damage caused by chemical agents such as unsuitable cleaning materials. When cleaning or disinfecting, make certain: that the electrical plug is disconnected, that no fluids enter the interior of the unit, as this can lead to faults. 3

A 2 Installation Leuchte darf nicht über der Bunsenbrennerflamme positioniert werden. The light must be securely positioned on the mounting surface by means of the provided adapter part 3. For the location of the adapter part, it is necessary to bore a 36 mm diameter hole through the mounting surface. Guide the electrical cable from above through the hole. Locate the cable in the notch 1 of the adapter part. Provide sufficient cable (looped). 3 Mount the adapter to the surface using 3 screws 4. Insert the light into the adapter. Tighten screw 2 at the adapter as needed. 4 2 3 1 A 3 Electrical connection Ensure that the local voltage agrees with the nominal voltage indicated on the rating plate, before connecting to the mains supply. The light is then connected to the provided installation with a special plug. 1 Operating voltage 2 Type of unit with material number (reference number) 3 Manufacturer 4 Bar code 5 Serial number 6 CE mark according 7 Important: see accompanying documents and safety information. 2 1 9 3 KaVo Elektrotechnisches Werk GmbH D-88299 Leutkirch EWL Type 5220 REF 10022738 110-230 V 50/60 Hz 1x55W Ersetze jede defekte Schutzscheibe Made in Germany F 4 5 0103004370 8 Lights - suitably for direct attachment on normally inflammable attachment surfaces. 8 7 6 9 Lamp achievement 4

A 4 Setting up Mounting left or right on the workstation. To adjust the light from the right R to the left L of the workstation, it is necessary to turn the jointed arm 3 180. 1 A 4.1 Turning the jointed arm Loosen screw 5 underneath the joint head 1. Turn arm 3 180 B. Re-tighten screw 5 under the joint head. 4 L R 2 3 A 4.2 Adjusting the hinge-joints The two main hinge-joints are adjustable by means of a lever 2. Each joint is adjusted so that the light can be easily moved, but the joint remains in the desired position. The ball joint 4 at the light-head can be adjusted right or left from the joint as required, with the two screws. B B 3 1 2 A A 5 Operation Leuchte darf nicht über der Bunsenbrennerflamme positioniert werden. A Safe operation and safety in general can only be ensured by correct use according to the instructions for use, maintenance and installation. The manufacturer accepts no liability for damage or injury resulting from incorrect operation. Correct use is possible only through compliance with the requirements of EN 61010. - Indoor use - Temperatures between 5ºC and 40ºC - Max. relative air humidity 80% at temperatures up to 31ºC reducing linearly to 50% relative air humidity at 40ºC. - Supply voltage fluctuations must not be greater than ± 10% of the rated voltage. - Overvoltage category II - Degree of pollution 2 (according to IEC 664) 6 5 Compliance is required with accident prevention regulations. Switching on and off The light is switched on and off with the rocker switch on the arm. 5

A 6 Maintenance, repair and disposal Before any repair or maintenance work, disconnect the light from the mains supply! This work must be carried out only by a trained electrician! Only spare parts authorised by the manufacturer must be used. 2 1 A 6.1 Changing a fluorescent tube Open the light 3 Insert a screwdriver 3 between the reflector housing 1 and the diffuser 2, and lift out the diffuser 2. Press the red knob a on the lamp holder, and take out the tube b. Lampe einsetzen Den roten Knopf a an der Lampenfassung drücken und den Lampensockel vorsichtig eindrücken b. Der Lampensockel muß in die Lampenfassung einrasten und fixiert sein danach roten Knopf a losslassen. Lampe in die Lampenhalterung einrasten. Blende 2 einsetzen Blende 2 über die 6 Rastbolzen in das Reflektorgehäuse einrasten. 4 5 A 6.2 Disposal 7 6 At the end of its life, the fluorescent tube must be disposed of in accordance with local regulations. Defective fluorescent tubes must be disposed of as special waste. 2 6

A 7 Operating faults Repair and maintenance work on the elec-trical part of the lamp must be carried out only by trained persons or personnel trained in the factory who are familiar with the safety regulations. Before opening parts of the housing, unplug the power plug or dis-connect the appliance from the supply connection on all poles to ensure that the lamp has no voltage applied. F Illumination is no longer adequate C Protective shield dirty R Clean protective shield (see A 1.5) C Fluorescent lamp defective R Exchange florescent lamp (see A 6.1) C Fluorescent lamp worn out R Exchange florescent lamp (see A 6.1) F Work bench lamp no longer lights C Power supply open circuit R Check or have an authorized dealer check the supply connection, main fuse, plug connections C Fluorescent lamp defective R Exchange fluorescent lamp (see A 6.1) C Ballast defective R Have an authorized dealer change the ballast F = Fault C = Cause R = Rectification 7

A 8 Technical data General data Classification: - Protection class I - Protection type IP20 - not suitable for rooms with risk of explosion Pollution level 2 Overvoltage category ll Amblent conditions: Permissible in inner rooms Permissible ambient temperature range 5 C - 40 C Permissible up to a max. relative humidity of 80% Type of operation: continuous operation Technical safety test: in accordance with EN 60 598-1 Dimensions Lamp housing approx 590 x 135 x 85 mm Struts ca. 430 + 560 mm Electrical values Rated voltage Voltage range: Consumption 100 / 120 / 230 V 50 / 60 Hz ca. 48 W Performance factor ca. 0,96 Lamps utilised Compact fluorescent tube 1 x 55 W Starter unit Multi-voltage EVG integrated We reserve the right to make any alterations. 8

Guarantee conditions Under valid KaVo EWL delivery and payment conditions, KaVo EWL gives a guarantee of satisfactory function and freedom from faults in material and manufacture for the duration of 6 months from the date of sale certified by the vendor. After expiry of the warranty, KaVo gives a guarantee of another 6 months for damage attributable to deficiencies in the material or in manufacture. In the case of justifiable complaints, KaVo EWL shall supply spare parts or carry out repairs free of charge. KaVo EWL accepts no liability for defects and their consequences which have arisen or could have arisen as a result of natural wear, improper handling, cleaning or maintenance, noncompliance with the maintenance, operating and connecting instructions, corrosion, impurities in the air supply or chemical or electrical influences which are unusual or not admissible in accordance with KaVo's instructions. The guarantee shall become null and void if defects or their consequences can be attributed to interventions in or modifications to the product. Guarantee claims can only be validated if they are notified immediately in writing to KaVo EWL. 9

1.003.0839 1.003.0840 1.003.0836 1.003.0844 1.003.0838 1.003.0837 1.003.0867 1.003.0847 1.003.0849 1.003.0850 1.003.0851 1.003.0848 1.003.0841 1.003.0854 1.003.0853 1.003.0857 1.003.0852 1.003.0846 1.003.0842 1.003.4184 1.003.0843 1.003.0845 1.003.0856 Anschlusskabel bei MASTERspace und Fremdtisch 1.003.0862 1.003.0861 1.003.0858 1.003.0859 1.003.0865 0.223.4232 D 1.000.5677 CH 1.000.5678 GB 1.000.5679 AUS 0.692.9201 USA/J 1.003.0864 1.003.0855 1.003.0853 1.003.0852 1.003.0864 Schaltplan 1.003.0863 1.003.0866 1/ 10

11

RB 06/04 GB 17.02 1.002.3858 D-88299 LEUTKIRCH. Telefon 0 75 61/86-150 Fax 0 75 61/86-265 Internet: www.kavo.com