Similar documents
CR193 B,C,D and E Vacuum Limitamp * Contactors

CR193 Vacuum Limitamp* Contactors

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

DEF-002. Vacuum Limitamp Medium Voltage Motor Control. wal Parts

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Ampgard medium voltage motor control renewal parts

Instruction sheet WARNING. October, 2014

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

Installation Sheet January, 2016 Supersedes February, 2013

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

T300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

Power Break Circuit Breakers

Operation and Maintenance Manual

Installation Sheet January, 2016 Supersedes June 2013

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

Florham Park, NJ USA Call (ASCO) for sales or service

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits

DEF-002. Vacuum Limitamp Medium Voltage Motor Control CR194

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Illustrated Parts List for GPU-400

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

Medium Voltage Equipment. Section 15.

C E R T I F I C A T E O F C O M P L I A N C E

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Cradle Mounted Key Interlock Guide Frame Accessory

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Universal Retrofit System Installation Instructions Revised:

Section 11. Specialty Control Devices. Control Catalog 11-1

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Vacuum Contactors and Starters

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Magnetic Overload Relays

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

SIGNAL WORDS QUALIFIED PERSON

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

GE CONSUMER & INDUSTRIAL

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

Installation Instructions For Motor Control Center (MCC) Units

LBI-30246F INSTRUCTIONS FOR FUSE PANELS 19C327027G1, G2, G4, G5, G8, G9, G10, G11, G14 & G15 AND FILTER PANEL 19D423732G1 DESCRIPTION

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Programmable Logic Controller. Mat Nor Mohamad

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

SECTION PANELBOARDS

A200 NEMA Contactors and Starters A200

A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits

Florham Park, NJ USA Call (ASCO) for sales or service

DEH Installation

Heavy Duty DC Contactors for Power Distribution Centres

Certi 堵脝 cation Record

Medium Voltage Metal-Enclosed Switches

C E R T I F I C A T E O F C O M P L I A N C E

2.54mm Pitch Card Edge Connector

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS

DISCONNECT SWITCHES (16 TO 630 amp)

SecoVac * Ground & Test Device

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

Generator Fire Safety: Generator assemblies should be located outside the building.

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Description. Positive safety relays

NEMA Vacuum Break Contactors and Starters

Table of Contents. HCC Contactor Nomenclature

GEF~4630A. Limitamp Medium-Voltage Motor Control. CR7160 Renewal Parts Bulletin

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

Low-Peak 600V Class RK1

Cutler-Hammer. AMPGARD MV Motor Control Vacuum Break SJ Series II II. Renewal Parts. r II li I. Pages. Contents. Effective: March 2000 Page 1

1800/1000 Frame RC Snubber Board IS200RCSAG1A

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches 150 through 4000 amp. Rating Label. Nameplate A

Type SOQ Negative Sequence Time Overcurrent Relay

Contactor V-Contact VSC/P

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Transcription:

Table Of Contents Wire 00 Vacuum Top Adjustment Auxiliary Coil General Guide Mechanical Bottle Bottom Drawout and Assemblies Assemblies Harnesses Assemblies Guide Terminal information 800 Bottle Contactor Interlocks Tool Amp Latch Assemblies Assemblies Kits Assemblies Contactors Parts CRI9B, C & D Renewal Pals Bulletin ~ 6 6 6 7 8 8 8 rhese instructions do not purport to cover all details or variations in equipment for every possible contingency to be met in connection with nstallation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser's purposes, the matter should be referred to the nearest GE SaIA!: Offi"A

CRI9B, C & D Renewal Parts Bulletin General Information This renewal parts bulletin will provide the proper identification of standard parts which may be required for the maintenance of CR9B & D (00A) and CR9C (800A) Vacuum Limitamp contactors. iboth the complete contactors and required renewal parts are shown as catalog numbers and are supported by photographs. Catalog numbers identified in this bulletin may not be the same as those parts on the original equipment. The renewal part catalog numbers are shown in kit form. It is the intent of this bulletin to give our customers a quick and accurate way to identify parts required for normal maintenance of the Vacuum Limitamp contactors. Unless otherwise stated, all of the parts shown in the bulletin are compatible with the contactors manufactured since 98. Since contactors are supplied to meet specific customer control and distribution requirements, certain replacement parts not listed in this publication may occasionally be required. Please refer to the factory for these requests. In these situations, please provide a complete description of the part, along with the complete data shown on the contactor nameplate that is affixed to the top of the contactor. For pricing and availability of parts shown in this bulletin, contact your nearest GE sales office. ~ttention should be g iven to forecasting lour particular renewal parts requirements :0 ensure on-site availability of the specific )arts as required for normal maintenance ~nd proper operation of your equipment. ro maintain maximum operating efficiency nd reliability of your equipment, genuine E renewal parts are recommended.

CRI.9.B, C & D Renewal Pal'fs Bulletin 00A and 800A Vacuum Contactor Fig. Contactors can be identified by their catalog number, located on the nameplate on the top of the contactor. Note: 00A contactor shown in photo 00 Amp Contactor 800 Amp Contactor CR9B & D Vacuum contactors are designed for equipment used in starting AC motors with line voltages from 000-Volts to a maximum of 700-Volts, transformer feeders, and other medium voltage control equipment Contactor Bracket and Pin Assembly Control Wire Harness Plug Bracket and Socket Assembly (not shown) CR9C Vacuum contactors are designed for equipment used in starting AC motors with line voltages from 000-Volts to a maximum of O00-Volts, transformer feeders, and other medium voltage control equipment BG See Fig. BG Contactor Catalog Number System + Voltage for contactor main coil is always 0/ VOC * The sum of normally open, normally closed, and late opening normally closed ~ contacts must be a multiple of five (). Each interlock block contains five () contacts. A contactor may contain a maximum of four () blocks, two () being the maximum on either side. Only five () late opening normally closed contacts are available on a contactor. Typical contactor number: CR9Bll0LO00U

CR9.:E, C& D Fenewal Parts Bulletin Fig. Fig. Coil Assembly ~cription rn9b rn9c, & D, 00 arrp contactor 800 arrp contactor pan NurTJer D78~ D780GR Note".00\ coil shown in pooto Fig. Fig..e \~' 00 o o Vacuum Bottle Assembly Guide Assembly ption Part NurrtJer - O70000GR' CR9B & D, 00 a"'p contactor Part NurTiJer O7reCXR' CR9C, 800 an-p contactor

CRI9.B, C & D Renewal Parts Bulletin Fig. 6 Fig. 7 ~ Contactor Top Assembly Contactor Adjustment Tool Kit CR98 & D, 00 amp contactor D78008GR CR98 & D, 00 amp contactor 0A900DCGl CR9C,800 ampcontactor D780GR CR9C, 800 amp contactor 0A900DCG Note: 00A top assembly shown in photo Note: 00A tool kit shown in photo Fig. 8 Mechanical latch Assembly 0/ VDC VDC C67989GRA C67989GRB

CRI9.B, C & D Renewal Parts Bulletin Fig. 9 800 Amp Block 00 Amp Block Auxiliary Interlocks The table below lists all possible combinations of auxiliary interlocks within a single block. Select the contact arrangement desired and add the suffix letters to the appropriate part number (i.e.. C679809GRP). Contactor CR9B & D, 00 Amp contactor CR9C, 800 Amp contactor C679809- C6798- Suffix GlRP GRP GRP GRP GRP G6RP G7RP GBRP G9RP GlORP GllRP NO NC LONG Suffix GRP GRP GRP GRP G6RP G7RP G8RP G9RP G0RP GRP NO NC LONG

Drawout Contactor (CR9D) Parts ~ CR9B, C & D Renewal Parts Bulletin Fig. 0 Fig. Bottle Guide Bottle Guide Assembly Bottom Terminal Assembly D escription CR9B & D, 00A contactor CR9C, 800 A contactor Note: 00A top assembly shown in photo D780GR D7807GR CR9B, 00A contactor CR9D,00A drawout contactor CR9C, 800A contactor Note: 00A terminal parts shown in photo D78008GR D78008GR D780GR Fig.