INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

Similar documents
INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED ETF-600/610 LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Optima ETF-600/ETF-610

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC ACTIVE IR LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR PISTON TYPE FLUSHOMETER EXPOSED CLOSET AND URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR DOUBLE AND TRIPLE STATION SENSOR ACTIVATED SOLID SURFACE LAVATORY SYSTEMS

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC INFRARED SENSOR ACTIVATED LAVATORY FAUCETS. Below Deck, Mechanical Below Deck, Thermostatic

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL AND REGAL XL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEMS SENSOR ACTIVATED ROYAL CONCEALED and EXPOSED URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR EXPOSED GEM 2 PISTON TYPE WATER CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

BASYS Infrared Sensor Activated

INSTALLATION INSTRUCTIONS FOR SENSOR ACTIVATED CROWN & CROWN II FLUSHOMETER EXPOSED CLOSET & URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS FOR CONCEALED CLOSET AND URINAL FLUSHOMETERS

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED SLOAN EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Control Stop. H-710 Stop, chrome plated: Screwdriver Angle Stop with H-573-A Locking Vandal Resistant Cap

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

Control Stop H-700-A 3/4 NPTF inlet for adjustable tail H-700-A 1 NPTF inlet for adjustable tail

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

LIMITED WARRANTY. Exposed Urinal Flushometer for 1-1/4" Top Spud MODEL 180 Exposed Urinal Flushometer for 3/4" Top Spud MODEL 186

Maintenance Guide. OPTIMA Components:

INSTALLATION INSTRUCTIONS FOR SOLIS SOLAR-POWERED SENSOR-ACTIVATED CONCEALED FLUSHOMETERS

Installation. Aerada 1200 Series CS Faucet S Battery-Operated Capacitive Sensing Gooseneck Faucet IMPORTANT

G2 Optima Plus Flushometer

BASYS Infrared Sensor Activated

INSTALLATION INSTRUCTIONS FOR OPTIMA SYSTEM SENSOR ACTIVATED ROYAL EXPOSED WITH TRUE MECHANICAL OVERRIDE FLUSHOMETERS ROUGH-IN

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

MAC FAUCETS FA400 WALL MOUNT FAUCETS

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Electronic Faucet 1500T & 1501T Series

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Reducing Your Water Footprint

INSTALLATION INSTRUCTIONS SLOAN SERIES 900 HYDRAULIC FLUSHING SYSTEM FLUSHOMETERS EXPOSED CLOSET, URINAL & SERVICE SINK INSTALLATIONS.

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

LIGATURE RESISTANT SENSOR FAUCET

Installation Instructions

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Aqua-FIT Serio Series TM

MAC FAUCETS. FA400 Autoluxe Faucets

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Milano AUTOMATIC FAUCET

Installation S AST4 S TT S IR. Stainless Steel Wall-Hung BradMate Washfountain

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Installation Instructions

MAC FAUCETS. FA400 Wall Mount Sensor

Installation. S AST4 S TouchTime S Infrared. Stainless Steel Wall-Hung BradMate Washfountain

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Installation Instructions

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

EcoVantage AV. ZRK Dual Flush Series. Sensor-Operated, Battery-Powered Retrofit Kit. Installation, Operation, Maintenance, and Parts Manual

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Model 1001/1001HPS Drinking Fountain

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

Installation Instructions

Installation Instructions

Troubleshooting Guide HYBRIDFLUSH AEF-801 SERIES

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Installation Instructions

864293A02 4.3L (262 CID) MANIFOLD CONVERSION

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

Installation MF2922/BIR3

DTC C1268/68 Transfer "L4" Position Switch Circuit

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

AutoFaucet. with Surround Sensor Technology. Installation & Maintenance

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

INSTALLATION INSTRUCTIONS

Installation Instructions

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Transcription:

ode No. 0816318 Rev. 1a (11/08) INSTLLTION INSTRUTIONS FOR SENSOR TIVTED LVTORY FUETS Model ETF-600 24 V, Sensor ctivated, 4 enterset Lavatory Faucet Model ETF-610 24 V, Sensor ctivated Pedestal Lavatory Faucet ompliant to: SME 112.18.1 and S 125.1 LIMITED WRRNTY Sloan Valve ompany warrants its ETF-600 and ETF-610 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, Sloan Valve ompany will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve ompany, at customer's cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve ompany's products directly from Sloan Valve ompany for purpose of resale. THERE RE NO WRRNTIES WHIH EXTEND EYOND THE DESRIPTION ON THE FE HEREOF. IN NO EVENT IS SLON VLVE OMPNY RESPONSILE FOR NY ONSEQUENTIL DMGES OF NY MESURE WHTSOEVER. PRIOR TO INSTLLTION Prior to installing the Sloan ETF-600 or ETF-610 Faucet, install the items listed below. Refer to Rough-in illustrations on Page 2. When Using Plug-In Transformer Install electrical receptacle for plugin transformer (120 V, 2 amp service for each ETF-233 (24 V, 35 V) plug-in transformer used). When Using ox Mount Transformer Install electrical wiring to transformer location (120 V, 2 amp service for each EL-248-40 (24 V, 40 V) transformer used). Lavatory/sink Drain line Hot and cold water supply lines or tempered water supply line Multiple Faucets Multiple faucets can be powered by a single transformer, provided that the transformer has been properly sized. llow a minimum of 15 V of current rating for each solenoid valve used. Refer to Step 4 Install Transformer for further information. Mixing Valve When installing the faucet with a Sloan mixing valve, these Installation Instructions ND the Installation Instructions packaged with the mixing valve MUST be followed. Important: INSTLL LL ELETRIL WIRING IN ORDNE WITH NTIONL/LOL ODES ND REGULTIONS. INSTLL LL PLUMING IN ORDNE WITH PPLILE ODES ND REGULTIONS. 24 V STEP-DOWN TRNSFORMER MUST E USED. USE PPROPRITE PREUTIONS WHILE ONNETING TRNSFORMER TO 120 V POWER SOURE. DO NOT PLUG TRNSFORMER INTO POWER SOURE (REEPTLE) UNTIL LL WIRING IS OMPLETED. LLOWING 24 V TRNSFORMER WIRES TO TOUH OR SHORT WHILE POWER IS EING SUPPLIED WILL USE PERMNENT DMGE TO THE TRNSFORMER ND IRUIT ONTROL MODULE. KEEP THRED SELNT OUT OF YOUR WTERWY TO PREVENT OMPONENT PRT DMGE! DO NOT USE NY SELNT ON OMPRESSION FITTINGS. FOR THREDED PIPE FITTINGS, DO NOT PPLY SELNT TO THE FIRST TWO STRTER THREDS. FLUSH LL WTER LINES UNTIL WTER IS LER EFORE ONNETING SOLENOID TO SUPPLY STOPS. DO NOT INSTLL THE SPRY HED UNTIL FTER THE SUPPLY LINES HVE EEN FLUSHED. K-HEK TEE USGE When connecting the Sloan ETF-600 or ETF-610 Faucet to both hot and cold water supplies, a ak-hek Tee is provided and required as illustrated in the Rough-in drawings on Page 2. Water temperature can be controlled by adjusting the supply stops. When connecting the faucet to a single line water supply or a pre-tempered water supply, a ak-hek Tee is not required. ak-hek Tee is not required or provided when a Temperature Mixing Valve is included with the faucet. TOOLS REQUIRED FOR INSTLLTION Open end wrenches for hex sizes: asin wrench 1, 5/8, 9/16, 1/2 Slotted screwdriver, 3/16 Slotted screwdriver (supplied) Phillips head screwdriver, #2 Pliers Wire stripper/crimping tool

FUET ROUGH-IN ETF-600 Faucet with ak-hek Tee for Hot and old Water Supply ETF-600 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply vailable Flow Rates: Model ETF-600 0.5 gpm (1.9 Lpm) Spray Head Model ETF-600-2.2 gpm (8.3 Lpm) erator Spray Head Model ETF-600-2.2 gpm (8.3 Lpm) Laminar Spray Head Model ETF-610 0.5 gpm (1.9 Lpm) Spray Head Model ETF-610-2.2 gpm (8.3 Lpm) erator Spray Head Model ETF-610-2.2 gpm (8.3 Lpm) Laminar Spray Head ETF-610 Faucet with ak-hek Tee for Hot and old Water Supply (shown with 4 trim plate) ETF-610 Faucet with DM Variation Mixing Valve for Hot & old Water Supply (shown with 8 trim plate) ETF-610 Faucet with DM and DT Variation Mixing Valves for Hot and old Water Supply (shown with 4 trim plate) ETF-600 Faucet ETF-610 Faucet 2

1 Install ETF-600 Faucet Note: Refer to the Installation Instructions included with the ETF-578- Trim Plate for additional information about using an 8" Trim Plate with an ETF-600 faucet. D Slide ase Gasket onto Faucet. 1/8 NPT PIPE NIPPLE Insert Faucet Sensor able, Pipe Nipple, and Mounting Studs through the 4 (102 mm) spread deck holes. FUET MOUNTING STUDS SE GSKET SENSOR LE SLOTTED MOUNTING WSHERS (2) WING NUTS (2) 1/8 NPT PIPE TO 3/8 TUE OMPRESSION FITTING Secure Faucet to deck using Slotted Mounting Washers and Wing Nuts supplied. pply thread sealant or Teflon tape to threads at end of Faucet Pipe Nipple. Install 1/8" Pipe x 3/8 Tube ompression Fitting on end of Faucet Pipe Nipple. 1 Install ETF-610 Faucet Note: Sloan Valve ompany recommends that this faucet be installed with our trim plate. Our trim plate includes an anti-rotation feature to prevent rotary motion of this single-hole pedestal-style faucet. D Slide ase Gasket over Faucet Water Supply Tube and Sensor able. Install optional Trim Plate, then Trim Plate Gasket. Holding Faucet ase Gasket and optional Trim Plate assembly in place, insert Sensor able and Faucet Water Supply Tube through the 1" (25 mm) center hole in deck or lavatory. Use plumber s putty to secure optional Trim Plate. Thread Sensor able through side of Mounting Spacer. Secure Faucet to deck or lavatory using Flat Washer, Lockwasher and Mounting Nut. FUET 1/4 NPT WTER SUPPLY TUE FLT WSHER LOKWSHER MOUNTING NUT SE GSKET MOUNTING SPER SENSOR LE 1/4 NPT PIPE TO 3/8 TUE OMPRESSION FITTING pply thread sealant or Teflon tape to threads at end of Faucet Water Supply Tube. Install 1/4" Pipe x 3/8 Tube ompression Fitting on end of Faucet Water Supply Tube. 2 Install Solenoid Valve Note: Flow direction of Solenoid Valve is indicated by arrow on Valve ody. ETF-600 onnect 3/8 O.D. Supply Tube between ompression Fitting on outlet side of Solenoid Valve and ompression Fitting on Spout s Pipe Nipple or Water Supply Tube. 1/8 PIPE NIPPLE 1/8 PIPE TO 3/8 TUE OMPRESSION FITTING ETF-610 1/4 WTER SUPPLY TUE 1/4 PIPE TO 3/8 TUE OMPRESSION FITTING 3/8 SUPPLY TUE (NOT SUPPLIED) SOLENOID VLVE 3/8 K-HEK OMPRESSION TEE (FOR PPLITIONS USING DUL WTER SUPPLY) 3/8 SUPPLY TUE (NOT SUPPLIED) SOLENOID VLVE 3/8 K-HEK OMPRESSION TEE (FOR PPLITIONS USING DUL WTER SUPPLY) 3 3 onnect Supply Line(s) Important: Keep thread sealant out of your waterway and prevent component part damage! Do not use sealant on compression fittings. When thread sealant is used, do not apply it to the first two starter threads. For Dual Line Hot and old Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and hot and cold supply stops. (Supply stops and copper supply tube furnished by installer.) Install a 3/8 inch (10 mm) copper supply tube between ak-hek ompression Tee and inlet side of Solenoid Valve. Tighten ompression Fittings securely. Note: Failure to install the ak-hek Tee can result in a cross flow connection when the faucet is off and the supply stops are open. If pressure of the hot and cold water supply differ, hot water can migrate into the cold water supply or vice-versa. Most plumbing codes require that the ak-hek be used to prevent this. For Single Line Water Supply pplications Install a 3/8 inch (10 mm) copper supply tube between the supply stop and inlet side of Solenoid Valve. (Supply stop and copper supply tube furnished by installer.) Tighten ompression Fittings securely. K-HEK TEE USED ON DUL WTER SUPPLY PPLITIONS ONLY SOLENOID VLVE SUPPLY TUE OMPRESSION FITTING SUPPLY STOP SOLENOID VLVE SUPPLY TUE OMPRESSION FITTING SUPPLY STOP Important: Flush dirt, debris, and sediment from the supply line(s).

4 Install Transformer ox Mount Transformers Multiple Faucets Multiple faucets can be powered by a single transformer that has been properly sized. llow a minimum of 15 V of current rating for each solenoid valve used. Refer to the following example to determine the required current rating for 3 OPTIM faucets. Example: Total number of OPTIM faucets: 3 Total number of solenoid valves: 3 Multiply by current rating: 15 V Minimum current rating of required transformer: 45 V Transformers vailable with the ETF-600 and ETF-610 Faucets Standard Plug-In ETF-233 120 V 35 V Standard ox Mount EL-248-40 120 V 40 V In anada, use ETF-416 (120 V, 35 V). Optional Transformers vailable from Sloan ox Mount EL-154 120 V 50 V Foot Mount EL-208 120 V 100 V ox Mount EL-342 240 V 50 V ll Sloan transformers are 50/60 Hz. Other transformers (not supplied by Sloan) may be used, provided they meet UL requirements for lass 2 transformers. Important: DO NOT supply power to primary side of Transformer until all wiring has been completed. Mount Transformer on a metal electrical junction box (supplied by others). ( J box should be mounted inside chase wall or above ceiling.) Install Transformer within 50 feet (15.24 meters) of Faucet. 18 gauge wire is recommended. Run wires from secondary side of Transformer to 3/8 inch (10 mm) hole at back of ontrol Module Enclosure. If necessary, wires can be run through wall and then inserted through hole in back of ontrol Module Enclosure. 24 V SEONDRY 120 V PRIMRY OX MOUNT TRNSFORMER (EL-248-40 SHOWN) Plug-in Transformers Important: DO NOT plug Transformer into receptacle until all wiring has been completed. The Transformer is supplied with a 10 foot able; however, this able can and should be shortened to meet installation requirements. ONTROL MODULE SE Strip ends of Transformer Power able approximately 3/16 to 1/4 inch (5 to 6 mm). Install Strain Relief 3 inches (76 mm) from one end of Power able. Insert Power able and Strain Relief into hole at back of ontrol Module. Install right angle Strain Relief so that Power able enters the ontrol Module from the bottom. Important: Twist stranded ends of Power able before inserting into Terminal lock. Fraying of Stranded Power able Wire can cause a short and damage the ontrol Module and Transformer when powered. PLUG-IN TRNSFORMER (ETF-233 SHOWN) STRIN RELIEF PLUG-IN TRNSFORMER TRNSFORMER TERMINLS D E onnect Power able to Terminal lock on onnector oard. See Step 6. Install rimp onnectors and connect Power able ends to Transformer Terminals. RIMP ONNETORS 4 POWER LE

5 Mount ontrol Module to Wall 6 ontrol Module onnection Install the ontrol Module in an appropriate location as shown in Rough-in. ontrol Module must be installed so that all cables enter from the bottom of the unit. When installed, ables from the Spout and Solenoid Valve to the ontrol Module should have some slack. Mount ontrol Module to wall using Mounting Screws and Plastic nchors. 4 (102 mm) Route ables from Solenoid Valve and Spout to the ontrol Module. Insert Solenoid Valve onnector into the Modular Receptacle on onnector oard. ONTROL MODULE ENLOSURE TERMINL LOK - 1. REMOVE TERMINL LOK 2. INSERT POWER LES 3. SEURE WITH SREWS 4. REINSTLL TERMINL LOK STRIN RELIEF SLOTS MODULR REEPTLE ONNETOR ORD POWER LE EXTENSION LES Extension ables are available as an option from Sloan to allow for installing the ontrol Module remote from the Faucet Spout and Solenoid Valve. Refer to the Parts List for available lengths. FROM FUET SPOUT D FROM SOLENOID VLVE FROM TRNSFORMER Insert Locking onnector from Faucet Spout into mating Receptacle on onnector oard. llow 3 to 4 inches (76 to 102 mm) of able to extend into the ontrol Module. Insert each onduit able into a strain relief slot in the ontrol Module. 7 Plug In Transformer Plug Transformer into 120 V Receptacle. 8 Start-up Supply power to Transformer. Note: The ontrol Module is equipped with two LED lights. When power is supplied by the Transformer, one LED will illuminate green. When Sensor is activated, this LED will change to red. second red LED illuminates when Solenoid Valve is activated. TRNSFORMER Open Supply Stop(s). With erator removed, activate Faucet for 30 seconds by placing hands in front of Sensor. The Solenoid Valve should click and water should flow from the Spout. If this does not occur, refer to the Troubleshooting section of this instruction instructions. lose Supply Stop(s) and install Spray Head in Spout using the Key provided. Reopen Supply Stop(s), activate Faucet and check for leaks. 5

9 Range djustment The OPTIM ETF-600 and ETF-610 Faucets are factory set to operate when hands are placed 4 to 5 inches (102 to 127 mm) from Sensor. This range should be satisfactory for most installations. If range adjustment is required, refer to the following range adjustment procedures. TO MKE RNGE DJUSTMENT The Range Potentiometer and Dip Switches are located in ontrol Module. Important: Range Potentiometer adjustment screw rotates only 3/4 of a turn; DO NOT over-rotate. Make certain that Dip Switch number 4 is in the UP position. Using the small screwdriver provided, adjust Range Potentiometer clockwise until green (power ON) indicator LED turns red (Faucet is now picking up sink). djust Range Potentiometer back counterclockwise until red LED returns to green. Range is now at maximum. ycle Faucet several times to assure that range as adjusted will not inadvertently pick up IR reflection in lavatory. If IR reflection occurs (green LED will flicker red), adjust Range Potentiometer counterclockwise very slightly and again cycle Faucet. Repeat range adjustment counterclockwise until length of range is at bowl rim of lavatory (plus or minus 1 (25 mm)). Time Out djustment The Faucet Time Out Setting determines the maximum time the Faucet will run upon continuous activation. This timing can be changed to meet individual application requirements. Refer to Table 1 or label on cover of ontrol Module along with the following instructions to set the desired Time Out. The Dip Switches used to set the Time Out are located in the ontrol Module. Set the Time Out by configuring the number 1, 2 and 3 Dip Switches as shown in Table 1. Table 1 Time Out Settings Time Out Dip Switch Setting Switch #1 Switch #2 Switch #3 3 SEONDS UP UP DOWN 6 SEONDS DOWN DOWN UP 12 SEONDS UP DOWN UP 30 SEONDS UP DOWN DOWN 45 SEONDS UP UP UP 1 MINUTE DOWN UP UP 3 MINUTES DOWN DOWN DOWN 20 MINUTES DOWN UP DOWN Unless otherwise specified, all ETF-600/ETF-610 Faucets leave the factory set with a 30 second Time Out. Note: The position of Dip Switch # 4 (range enhancer setting) does not affect Faucet Time Outs. Push ables into slots at the bottom of the ontrol Module. Install ontrol Module over using Screws provided. Refer to illustration in Step 7. Test Faucet Operation 1. continuous invisible beam of infrared light is emitted from the OPTIM sensor located at the base of the lavatory faucet. RE ND LENING OF HROME ND SPEIL FINISHES DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning the bathroom tile, protect the faucet from any splattering of cleaner. cids and cleaning fluids will discolor or remove chrome plating. 2. s the user s hands enter the beam s effective range (beneath the spray head), the beam is reflected back into the sensor receiver and activates the solenoid valve. Tempered water flows from the faucet into the sink until the hands are removed from the beam or until the faucet reaches an automatic time out limit setting. 3. When hands are moved away from the sensor, the loss of reflected light initiates an electrical signal that deactivates the solenoid valve, shutting off the water flow. The circuit then automatically resets and is ready for the next user. 6

TROULESHOOTING GUIDE Note: Remove over from ontrol Module to check diagnostic lights. 1. PROLEM: No water is delivered when Faucet is activated. INDITOR: If no LED lights illuminate: USE: No electricity is being supplied to Faucet. SOLUTION: Ensure that the main power is turned ON. heck all Transformer, Sensor, Solenoid and able onnections. Make sure that Transformer is supplying 24 V (Volts ). If no voltage is detected, replace Transformer. USE: There is an electrical system malfunction. SOLUTION: Reset electrical system. Unplug Sensor onnection. Disconnect power to circuit for ten (10) seconds. Reconnect. INDITOR: If the GREEN LED does NOT illuminate when power is reconnected: USE: There is an electrical system malfunction. SOLUTION: Reset electrical system. Unplug Sensor onnection. Disconnect power to circuit for ten (10) seconds. Reconnect. USE: The ontrol Module circuit is dead. SOLUTION: Replace ETF-450- ontrol Module. INDITOR: If GREEN LED illuminates ND changes to RED when hands are in the Sensor s detection zone ND the RED Solenoid LED illuminates: USE: Water supply stop(s) may be partially closed. SOLUTION: Open supply stop(s) completely. USE: Debris is clogging Solenoid Filter. SOLUTION: Shut off water supply. Remove, clean and reinstall Solenoid Filter. INDITOR: If GREEN LED illuminates ND changes to RED when hands are placed in the Sensor s detection zone ND the RED Solenoid LED flickers with a vibrating/clicking noise heard inside the module: USE: There is a direct short in the Solenoid or Solenoid able. SOLUTION: Replace with ETF-370- Solenoid. INDITOR: If GREEN/RED LED illuminates ND changes to RED when hands are NOT located in the Sensor s detection zone UT the RED Solenoid LED (in upper left corner of circuit) does NOT illuminate: USE: Sensor range is set too long and is detecting the sink. SOLUTION: Reduce Sensor detection range. USE: Sensor is faulty. SOLUTION: Replace Sensor. INDITOR: If GREEN LED illuminates UT does NOT change to RED when hands are placed in the Sensor s detection zone: USE: Sensor range is set too short. SOLUTION: Increase Sensor detection range. USE: Sensor is faulty. SOLUTION: Replace Sensor. 2. PROLEM: Sensing Range is too short. USE: Extended Range Sensitivity is required. SOLUTION: Dip Switch number 4 should be in the DOWN (Extended Range Sensitivity) position. Increase range by adjusting Range Potentiometer clockwise (yellow phillips screw in blue base). 3. PROLEM: Faucet activates by itself (false triggers). USE: Sensor range is set too long. SOLUTION: Decrease range by adjusting Range Potentiometer counterclockwise. If necessary, flip Dip Switch number 4 to the UP (Reduced Range Sensitivity) position. heck surroundings for factors that contribute to Sensor range detection problems (bright lights, highly reflective surfaces, sunlight, etc.). 4. PROLEM: Faucet delivers very low flow or just a dribble. USE: Water supply stop(s) may be partially closed. SOLUTION: Open supply stop(s) completely. USE: Debris is clogging Solenoid Filter. SOLUTION: Shut off water. Remove, clean, and reinstall Solenoid Filter or install Solenoid Valve repair kit ETF-1009-. USE: Solenoid is worn or faulty. SOLUTION: Rebuild with ETF-1009- Solenoid Repair Kit or replace ETF- 370- Solenoid. USE: Debris is clogging Faucet erator or Spray Head. SOLUTION:Shut off water. Remove erator or Spray Head (use Key if required). lean and reinstall erator or Spray Head. 5. PROLEM: Faucet does not stop delivering water or continues to drip after user is no longer detected (even after power to the Module has been disconnected). USE: Solenoid Valve is installed backward. SOLUTION: Disconnect Solenoid. Reconnect Solenoid with water flow toward the Faucet (see arrow on Solenoid). USE: Debris is clogging Solenoid. SOLUTION: Remove and clean Solenoid Operator. If necessary, rebuild with ETF-1009- Repair Kit. USE: Seat in Solenoid Valve body is damaged or pitted. SOLUTION: Replace with ETF-370- Solenoid. When assistance is required, please contact Sloan Valve ompany Installation Engineering Department at: 1-888-SLON-14 (1-888-756-2614) OR 1-847-233-2016 7

PRTS LIST 3 ETF-600 2 1 8 7 12 3 9 ETF-610 2 1 8 11 4 5 6 10 4 14 16 5 13 13 15 Item Part Description No. No. 1 ETF-543- Faucet Spout and Sensor ssembly (ETF-600) 1 ETF-570- Pedestal Faucet Spout and Sensor ssembly (ETF-610) 2 ETF-1023-0.5 gpm (1.9 Lpm) Spray Head with Key (male thread) ETF-1024-2.2 gpm (8.3 Lpm) erator Spray Head with Key (male thread) ETF-1029-2.2 gpm (8.3 Lpm) Laminar Flow Spray Head (male thread) 3 ETF-435 Replacement Key Only for ETF-1023- Spray Head and ETF-1024- erator Spray Head 4 ETF-546- Faucet Mounting Kit for ETF-600 includes: ase Gasket, two (2) Slotted Mounting Washers, two (2) Wing Nuts, and ETF-547 ompression Fitting onnector 4 EF-123- Faucet Mounting Kit for ETF-610 includes: Spacer, ase Gasket, 1/4 NPSM Hex Nut, Washer, 9/16 Lockwasher, ompression Fitting onnector 5 ETF-547 1/8 NPT Pipe to 3/8 Tube ompression Fitting onnector (ETF-600) 5 EF-129 1/4 NPT Pipe to 3/8 Tube ompression Fitting onnector (ETF-610) 6 ETF-617-3/8 ak-hek Tee ompression Fitting 7 ETF-370-24 V Solenoid Valve ssembly, includes Wire Harness 8 ETF-437- ssembly Kit, includes: ompression Fittings (2), ompression Nut (1), ompression Sleeve (1) 9 ETF-450- ontrol Module ssembly 10 ETF-233 Plug-In Transformer 11 EL-248-40 ox Mount Transformer 12 ETF-458- Power able with Strain Relief and rimp onnectors (Transformer to ontrol Module) OPTIONL TRIM PLTES 13 ETF-607-4 (102 mm) enterset Single-hole Trim Plate Kit for ETF-610 Faucet 13 ETF-608-8 (203 mm) enterset Single-hole Trim Plate Kit for ETF-610 Faucet MIX-102-4 (102 mm) enterset Double-hole Trim Plate Kit for ETF-610 Faucet with Optional Mixing Valve MIX-106-8 (203 mm) enterset Double-hole Trim Plate Kit for ETF-610 Faucet with Optional Mixing Valve ETF-578-8 (203 mm) enterset Single-hole Trim Plate Kit for ETF-600 Faucet ETF-577-8 (203 mm) enterset Double-hole Trim Plate Kit for ETF-600 Faucet with Optional Mixing Valve Item Part Description No. No. OPTIONL MIXING VLVES 14 MIX-60- elow Deck Mechanical Water Mixing Valve (DM Variation) 15 MIX-135- elow Deck Thermostatic Water Mixing Valve (DT Variation) 16 MIX-110- Optimix Deck Mounted Water Mixing Valve (DM Variation) (only available for ETF-610 faucet) FUET LE EXTENSION ORDS Faucet to ontrol Module Solenoid to ontrol Module ETF-1005-26 26 (0.7 meter) Length ETF-1003-36 36 (0.9 meter) Length ETF-1005-36 36 (0.9 meter) Length ETF-1003-48 48 (1.2 meter) Length ETF-1005-72 72 (1.8 meter) Length ETF-1003-72 72 (1.8 meter) Length ETF-1005-108 108 (2.7 meter) Length ETF-1003-108 108 (2.7 meter) Length SOLENOID VLVE REPIR KIT ETF-1009- Includes replacement Filter For additional information about Sloan Mixing Valves or Trim Plates, consult our Installation Instructions and Maintenance Guides. If further assistance is required, please contact the Sloan Valve ompany Installation Engineering Department at: 1-888-SLON-14 (1-888-756-2614) The information contained in this document is subject to change without notice. SLON VLVE OMPNY 10500 Seymour venue Franklin Park, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com opyright 2008 SLON VLVE OMPNY Printed 11-08