Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106

Similar documents
Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-380E/44 Series

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-128-1, RG-128-2, RG-128-3

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA RG-131

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 91790

COMPONENT MAINTENANCE MANUAL HCU-2 HEATER CONTROL UNIT (AND ASSOCIATED BATTERY HEATING ELEMENT)

PERFORMANCE SPECIFICATION SHEET BATTERY, STORAGE, AIRCRAFT, MAINTENANCE-FREE, 24-VOLT, 1.5-AMPERE-HOUR

COMPONENT MAINTENANCE MANUAL HCU-3 HEATER CONTROL UNIT (AND ASSOCIATED BATTERY HEATING ELEMENT)

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173

COMPONENT MAINTENANCE MANUAL HCU-4 HEATER CONTROL UNIT (AND ASSOCIATED BATTERY HEATING ELEMENT)

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS MAINTENANCE MANUAL SUPPLEMENT CONCORDE TS-C1 SERIES TEMPERATURE SENSOR

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS MAINTENANCE MANUAL SUPPLEMENT. CONCORDE TS-C2 or TS-C2A TEMPERATURE SENSOR

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD25-( ) Series Airspeed Indicator. REV. B May 31, 2010 MANUAL NUMBER

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product

CERTIFICATE OF ACCREDITATION

PERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE- HOUR, BB-475/A CELL

ST 26 Tach Generator Adapter

European Technical Standard Order (ETSO)

NATO CODE NUMBERS. Scope of list

Luminus Series Amphenol Pcd

Aircraft batteries Hawker

Specification Approval Sheet

Specification Approval Sheet

VIA Platform Environmental Qualification Testing Standards

CONCORDE BATTERY CORPORATION 2009 San Bernardino Road West Covina, CA Phone:

CONCORDE BATTERY CORPORATION 2009 San Bernardino Road West Covina, CA Phone:

Chapter 3. Direct Current Power. MElec-Ch3-1

IEC 62133:2012 (2nd Edition) Understanding IEC Safety Requirements for Rechargeable Cells & Batteries used in Portable Devices

QUALIFICATION TEST SUMMARY REPORT ESR Qualification Type Testing of Amphenol Corporation s 2M801 Series Connector

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

mm mm mm (Height at the top of terminals) 14.4 kg

AEROSHELL PRODUCT SPECIFICATIONS

Known Worldwide as the Highest Quality AGM Batteries for Marine, RV and Industrial Applications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

38999 Series III Composite Connectors

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, 10 AMPERES AND LOW LEVEL, UNSEALED

Lithium Battery Systems for Aerospace Applications

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, PLUNGER, 10 AMPERES 2PDT AND 7 AMPERES 4PDT, RESILIENT SEAL

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

Ministry of Defence Defence Standard 61-21

PEGASUS SERIES. Amphenol Pcd. Amphenol Pcd

This specification is applicable to the Nickel -Metal Hydride rechargeable batteries for type H320BC Model : H320BC

PAKISTAN STANDARD LEAD ACID STARTER BATTERIES - Part-1: General Requirements and Methods of Test. (All Rights Reserved) PS: 206-1/2012 (2 nd Rev.

Acme NonStop Power. FNC Cell Technology Sealed fiber nickel-cadmium battery systems For commercial, military and space systems.

PERFORMANCE SPECIFICATION SHEET

TRANSPORT OF DANGEROUS GOODS

Series 80 Mighty Mouse Technical Reference Complete Product Specification

Guidelines for Battery Electric Vehicles in the Underground

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

SLA Battery Capacity Analyzer

Integrated Back-up Battery System

NCPP. Nickel Cadmium Pocket Plate Batteries. Single Cell Dimensional and Electrical Data

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, SPDT, UNSEALED

Battery Information Sheet

B 344 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers.

European Aviation Safety Agency. European Technical Standard Order. ED Decision 2016/013/R Annex II. Subject: FUEL DRAIN VALVES

RS Stock number


Features and Application

Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION

DuraSeal Heat-Shrinkable Environmentally Sealed, Nylon Insulated Crimp Terminals and Disconnects

Acme NonStop Power. FNC Cell Technology

Amphenol 348 Series High Density Connectors

QUALIFICATION TEST REPORT

Lithium battery knowledge

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

for Quadrax and ELIO 8

SPECIFICATIONS SEALED NICKEL CADMIUM RECHARGEABLE BATTERY N1700SC-HTP

Specification of Battery Charger

M-3025CB-AV Fuel Pump

Ni-Cd Battery Product Specification

Sealed Rechargeable Nickel Cadmium N800AA/BTNP

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

MATERIAL SAFETY DATA SHEET & IATA T1 T8 CERTIFICATE. Model(s): AM

Checkup. Make. Signature. Date. Company Stamp: com

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ZS4-SF1 Screw Clamp Terminal Block

Product Specification Rev A

THREADED & BAYONET CONNECTORS FOR DEMANDING ENVIRONMENTS

TO: HOLDERS OF THE ENGINE FIRE EXTINGUISHER SERVICE BULLETIN , DATED JAN 13/06. REVISION NO. 1, DATED JUN 22/06 HIGHLIGHTS

Tenergy Corp 1292 Kifer Road Suite 807 Sunnyvale CA 94086

TYPE TEST REPORT. OPzS CELLS AND BLOCK BATTERIES. According to IEC

NI-MH LOW-SELF DISCHARGE READY TO USE

Stationary Battery Safety An Overview of the Process of Verifying the Safety of Battery Systems

Page 2 of 23 UNT150420C11

(1,5 modules per pole)

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

The Landscape of Thermal Runaway Propagation Testing

Bodies Brass Nickel or Gold Gold Female: Beryllium copper Insulator Teflon N/A Crimp ferrule Annealed copper Nickel or Gold

NANOpure Infinity UV Module Upgrade

Datasheet / Product specification Model: Solar AAA

Product Safety Data Sheet

SPECIFICATION FOR VT D 70 CONTENTS

DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

ZAVOD AIT Nickel-Cadmium Cells and Batteries

Transcription:

Concorde Battery Corporation 2009 San Bernardino Road West Covina, California, USA 27106 RG-500 and RG-600 Series 24 VOLT 17 Ah, VALVE REGULATED, LEAD-ACID, AIRCRAFT BATTERY DECLARATION OF DESIGN PERFORMANCE TO THE REQUIREMENTS OF RTCA DO-293 and Applications: Engine Starting and Emergency Power NOTE: Applications may not be a complete list of all applications for this battery type. The data/information contained herein has been reviewed and approved for general release on the basis that this document contains no export-controlled information User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 1 of 6

Characteristic Description RTCA DO-293 The RG-500 and RG-600 Series are 24 volt valve regulated lead acid batteries designed for engine starting and emergency power. The batteries consist of two MB12-17AA monoblocs connected in series. Each monobloc is made of a polypropylene container and cover. The monoblocs are connected in series. The RG-500 and the RG-600 series are substantially identical. Each house the complete monobloc assembly in an aluminum container and cover. The cover is attached to the container with high retention rivets. Each are integrated with a polypropylene handle assembly fitted around the cover. Both are manufactured with an identical hold down design and identical MS3509 conforming receptacles. Two perforated vent areas are machined into each side of the container for ventilation. The only difference is the location of the receptacle. There are three variations: RG-500, RG-600-1 and RG-600-2. The electrolyte is a sulfuric acid and water solution and is absorbed within the battery plates and separators. There is no free electrolyte. See Material Safety Data Sheet for hazardous material identification and precautions. The RG-500 and RG-600 series are electrically identical to the RG-222, electrical testing conducted on the RG-222 is considered representative of the RG-500 and RG-600 series batteries. Many environmental test results from the RG-222 are also considered representative of the RG-500 and RG-600 series batteries due to similarities in material and construction. For a complete analysis of the test battery to the RG-222 and a summary of test results which may be considered representative see Concorde Report CB021709-1. Format IEC 60952-2 Concorde Drawing No.RG-500 Concorde Drawing No.RG-600 Connector IEC 60952-2 The RG-500 and RG-600 Series are fitted with a Type Q terminal conforming to MS-3509. Mass RG-500-19.1 kg Max (42 lbs). RG-600-19.1 kg Max (42 lbs). Charging method, 4.3 Constant potential at 28.25 V Any auxiliary None requirement: Ventilation DO-293, 1.9 IEC 60952-2 The RG-500 and RG-600 series have two perforated vent areas machined into each side of the container for ventilation. Flammability IEC 60952-2 The outer container and cover are fire resistant Spillability Non spill Electrical Performance Rated Capacity (C1) DO-293, 2.2.2, 5.1.1 Capacity at 18 C DO-293, 2.2.3, 5.1.2 Capacity at 30 C DO-293, 2.2.4, 5.1.3 Capacity at +50 C DO-293, 2.2.5, 5.1.4 Power Rating +23 C DO-293, 2.2.6.1, 5.2.1.1 17 Ah 11.0 Ah when discharged at the C1 rate. 8.0 Ah when discharged at the C1 rate. 18.0 Ah when discharged at the C1 rate. Ipp = 900 A, Ipr = 625 A User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 2 of 6

Characteristic RTCA DO-293 Power Rating -18 C DO-293, 2.2.6.2, 5.2.1.2 Power Rating -30 C DO-293, 2.2.6.3, 5.2.1.3 Rapid Discharge DO-293, 2.3.1 Capacity at 23 C, 5.3.1 Ipp = 600 A, Ipr = 425 A Ipp = 450 A, Ipr = 300 A 10.0 Ah when discharged at 10 times the C1 rate to 10 volts. Rapid Discharge Capacity at -30 C DO-293, 2.3.2, 5.3.2 3.5 Ah when discharged at 10 times the C1 rate to 10 volts. Charge Retention DO-293, 2.4, 5.4 Storage DO-293, 2.5, 5.5 Charge Stability DO-293, 2.6, 5.6, Class I Short-circuit Current DO-293, 2.7, 5.7 Charge Acceptance DO-293, 2.8, 5.8 Insulation Resistance DO-293, 2.9.1, 5.9.1 Dielectric Strength DO-293, 2.9.2, 5.9.2 Duty Cycle DO-293, 2.10 Performance, 5.10 Water Consumption DO-293, 2.11 Test, 5.11 Overcharge DO-293, no requirement Endurance, 5.12 Cyclic Endurance DO-293, 2.12, 5.13 Deep Discharge DO-293, 2.13, 5.14 Induced Destructive DO-293, 2.14 Overcharge, 5.15 Electrical Emissions DO-293, 2.15, 5.16 +23 C - Rating value for design = 90 % +50 C - Rating value for design = 50 % DO-293-1 year storage life test in process OK. Max battery temperature on charge = 50 C. Charge current fell during the charge period. Capacity at end of test > C1 Peak current = 1832 A Last recorded current = 850 A at 3.8s +23 C = 103% -18 C (battery with heaters only) N/A -40 C (battery with heaters only) N/A 100 cycles successfully completed. N/A Not tested 100 cycles successfully completed. N/A Battery contains no active electronics. User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 3 of 6

Characteristic RTCA DO-293 Environmental Performance Vibration DO-293, 3.1, 6.1 Acceleration DO-293, no requirement, 6.2 Operational Shock DO-293, 3.3.1, 6.3, Class I Crash Safety Shock DO-293, 3.3.2, 6.4 Explosion DO-293, 3.4 Containment, 6.5 Altitude DO-293, 3.5, 6.6 Rapid Decompression DO-293, 3.5.2 IEC 60952 no reqmt Temperature Shock DO-293, 3.6, 6.7 Fungus Resistance DO-293, 3.7, 6.8 Humidity DO-293, 3.8, 6.9 Qualified to DO-293 and DO-160E, Random Vibration test per Curve C, section 8, 1 hour per axis. Not tested Qualified to DO-293 and DO-160E, Category B. Qualified to DO-293 and DO-160E, Category B, impulse and sustained. Sustained per DO-160E Table 7-1, Aircraft type 5, Test type R, 20g s in each orientation. Qualified to DO-293 and DO-160E. The RG-500 and RG-600 Series successfully met the test requirement. Tested to 20621m (67654 ft) IAW DO-293. Tested from 2300m (8000 ft) to 20621m (67654 ft) IAW DO-293. Tested from +85 C to -55 C IAW DO-293. The RG-500 and RG-600 series successfully met the test requirement. Qualified to DO-293 and DO-160E Category F. All samples successfully met the test requirement. Qualified to DO-293 and DO-160E, Category B User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 4 of 6

Characteristic RTCA DO-293 Fluid Contamination DO-293, 3.9, 6.10 Salt Spray DO-293, 3.10, 6.11 Physical Integrity at DO-293, 3.11 High Temperature, 6.12 Flammability DO-293, no requirement, 6.13 Electrolyte Resistance DO-293, 3.12, 6.14 Thermal Sensors DO-293, 3.13, 6.15 Component DO-293, 3.14 Qualification tests, 6.16 Battery Airtightness DO-293, no requirement, 6.17 Test was performed on representative material samples. All samples successfully met the test requirement. Fluids tested: Fuels. Aviation Jet A fuel Aviation piston engine fuel (100LL AVGAS) Hydraulic fluids Mineral based (MIL-H-5606) Non-mineral based synthetic (MIL-PRF-83282 and MIL-PRF-87257) Lubricating oils Mineral based (MIL-L-6081) Ester based synthetic (MIL-L-23699) Internal combustion engine SAE 15W40 Solvents and cleaning fluids Isopropyl alcohol (TT-I-735) Denatured alcohol De-icing fluid Ethylene Glycol Propylene Glycol AMS 1424 (SAE AEA Type I) AMS 1428 (SAE AEA Type VI) Insecticides - none Sullage - none Disinfectants (heavy duty phenolics) - none Coolant dielectric fluid - none Fire extinguishants - none Qualified to DO-293 and DO-160E, Category S. Not tested. See Section 1 All samples met the specification requirements. N/A All components successfully met the test requirement. N/A User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 5 of 6

Characteristic RTCA DO-293 Cell Baffle DO-293, no requirement, 6.18 Strength of DO-293, 3.15 Receptacle, 6.19 Handle Strength DO-293, 3.16, 6.20 N/A = Not Applicable N/A. Applies only to nickel-cadmium batteries only. OK OK Authentication: Manufacturer. Concorde Battery Corporation Signed: Name of signatory: Title or Function:. John B. Timmons, PE Vice President Engineering User DDP, RG-500 and RG-600 Series, Rev NC 04/12/10 Page 6 of 6