Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Similar documents
Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Bullet Valve (BV) Series

42 Series MAConnect TM. 42 Series Plug-In Manifold

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

92 Series MAConnect with Sub D

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Direct solenoid and solenoid pilot operated valves

Bullet Valve (BV) Series

32, CONTENTS SMALL LARGE

MAC VALVES EUROPE, INC.

82 Series MAConnect with Sub-D

Specifications 54 Series Valve

MAC VALVES, INC. Rev. T

MAC Pulse Valve PV03 Series

MAC Pulse Valve PV06 Series

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

KRONES DIRECT REPLACEMENTS

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

ISO 5599/ Series Technical and Operating Data

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

Electrical Interface Dimensional Drawings Connector Kits

Section 2 Proportional Quick Exhaust

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

2035 Series Solenoid Pilot Actuated Valves

Compact Proportional Solenoid Valve

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

Technical Bulletin. MAC Valves, Inc., is pleased to announce. Introduction - Plunger up / Plunger Cooling / Counterblow Solutions

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

2012 Series Solenoid Pilot Actuated Valves

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

3 Port Solenoid Valve Direct Operated Poppet Type

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Series 581 ISO Pneumatic Directional Control Valves

Isonic Mod 3 Series 3000/ /2, 3/2 Direct - 4/2 Single & Double Solenoid Valves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

SSR SSR SSR SSR

LYCOMING CYLINDER PRICING

SOLENOID VALVES AND PNEUMATIC VALVES

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

EAGLE SERIES VALVES E3 AND E4 SERIES. A Solenoid coil is available in AC or. B Manual override plunger provides. C Valve body is tapped #10-32 and may

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Miniature Valves MH1. Extremely small, fast and versatile. Info 206

Contact Air Incorporated for further assistance. Ph:

Valve Products. Valve Products Section D. Valve Products. Catalog PDN1000-3US Parker Pneumatic

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

5 Port Solenoid Valve

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Valve Manifolds. Series Fielbus Electronics - 51

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

TECHNICAL BULLETIN. The main focus of MAC Valves is to offer an innovative product developed according to users experience and that provides:

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Action Automation & Controls, Inc.

Chapter 10: Valves for Pipe Mounting

Pilot Operated 2 Port Solenoid Valve for Dry Air

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Directional Seat Valve Series D4S (Denison)

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series VQ Port Solenoid Valve

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

Miniature Multimedia Valves

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

SOLENOID VALVES, SERIES

FKHS Series. 3 Jaw Parallel Motion Pneumatic Grippers. Mounting Hole. Sensor Capable. Bottom tapped holes. Dowel Hole & Slot

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

Introduction Section 1 Section 2 Section 3

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

INSTRUMENT PANEL CLUSTERS

5 Port Solenoid Valve

Transcription:

NEW Technology

Page Introduction Section 1 Section Section Section 4 Section 5 Section 6 Section 7 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 197 Bases according to ISO 5599 Pressure regulators 4 Intrinsically safe valves 99 Options 07 Supplemental technical information 1 1

Introduction MAC VALVES INC. has earned a reputation as an innovator in solenoid air valve technology as is evidenced by our numerous global patents. MAC s designs focus on offering customers the best performing products available on the market. Some of the key features MAC s products offer are: - reliability - compact packaging - speed - modularity - repeatability - specific application modifications - non lube service - low wattage - ease of maintenance - broad electrical options Many of these performance advantages are based on MAC s high shifting forces. MAC s patended oval shaped armature solenoid and 4-way pilot technologies are two new concepts which result in extremely high shifting forces in small packages. The patented Latching Solenoid is another new offering to the MAC product line. The latching solenoid provides the function of a double solenoid operated valve utilizing only one solenoid. I. OVAL SHAPED ARMATURE SOLENOID Maximized Shifting Forces Compared with typical round armature solenoids, the oval shaped armature design results in much higher shifting forces due to the following: Increased coil windings (amp turns) Increased core iron volume With more amp turns and core iron than conventional round armature designs, more shifting force is available to shift through contaminated air resulting in reliable shifting valves. Oval Shaped Armature New Concept Oval Shaped Armature Push Pin Available space used for increased AMP Turns and Core Iron Volume = Higher Magnetism = Higher Force Oval Armature Round Armature Optimized Use of space Wasted space Consult Precautions page 7 before use, installation or service of MAC Valves..

Introduction DIRECT SOLENOID POPPET VALVE EA SHORT STROKE Short Stroke = High solenoid force Short Stroke = High return spring force Short Stroke = Low current to shift solenoid EB B A IN solenoid force curve DIRECT OPERATED 10 MM DESIGN WITH OVAL SHAPED ARMATURE Balanced poppet, with no seals of any kind in a bore - no friction New patented MAC solenoid with oval shaped armature - provides high shifting force through more core iron and magnet wire Balanced poppet - high shifting forces - unaffected by fluctuations in air pressure Short stroke direct operated poppet valve (patented adjustable inlet seat controls stroke) - high shifting force - without small piston and no minimum operating pressure Large orifice 0.004 in minimum - resists clogging Strong return spring - high shifting force - even at low pressure Few parts - simple design Patented conical shaped exhaust seats act as cushions - eliminates cutting - long life Every valve calibrated for flow for a given coil wattage - consistent flow SOLENOID FORCE Oval Armature Additional Net Shifting Force { OVAL ARMATURE ROUND ARMATURE SOLENOID STROKE 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Introduction II. MAC s 4-WAY PILOT SYSTEM Maximized Shifting Forces The balanced 4-way pilot valve provides maximum shifting forces in both directions by supplying air alternately to each end section of the spool, similar to double acting rodless cylinder. This system provides maximized shifting forces, equal forces at energization and de- energization, with no resistance to shifting at either end. The result is increased shifting reliability and faster, more consistent response times. Small direct 4-way solenoid operated valve P SPRING VALVE SOLENOID New concept : 4-way pilot HIGH SHIFTING FORCE (De-energize) SHIFTING FORCES unaffected by changing air pressure (IN/EXH) - BALANCE - SHIFTING FORCES virtually unaffected by typically contaminated air - WIPING ACTION - Low friction minimizes resistance to SHIFTING FORCES - MINIMAL FRICTION - HIGH SHIFTING FORCE (Energize) DE-ENERGIZED 4-WAY PILOT VALVE ENERGIZED 4-WAY PILOT Solenoid pilot operated large valve EXH B IN Valves A EXH that don t stick 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

Introduction MAC DISTRIBUTORS NETWORK ACT LOCAL 0 years experience Local support Globally linked network Special solutions Global customer partnership 45 countries 00 service centers 500 employees $ 50 million inventory 1000 factory certified application specialists KEEPING YOUR MACHINES RUNNING AROUND THE CLOCK AROUND THE WORLD 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

Introduction Let us show you via high performance demonstration kits and animated software, HOW MAC S PERFORMANCE ADVANTAGES HELP MAKE YOUR EQUIPMENT MORE RELIABLE - FASTER - MORE REPEATABLE. TLD Traveling Lab Demonstration measures critical valve performance characteristics - Shifting forces, Response Time, Speed, Repeatability and Flow. PLD Proportional Lab Demonstration measures critical proportional regulation characteristics - Response Time, Accuracy, Hysterisis, Repeatability and Flow. Animation Animated Software shows inner workings of various Air Valves Designs - Powerful educational tool for learning about how air valves function. Other MAC VALVE literature: DESCRIPTION CURRENT TECHNOLOGY BUILDING BLOCKS BROCHURE CIRCUIT BAR CATALOG PROPORTIONAL VALVE CATALOG CATALOG CD SERIAL INTERFACE PRODUCTS MACONNECT SYSTEM CATALOG NUMBER 999CTCB 999ADVB 999CBCA 999PPCB 999CCDB 9999SI CONSULT FACTORY 999CTCB 999ADVB 999CBCA 999PPCB 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Introduction MAC Valves 18 month guarantee plus lifetime coil guarantee The MAC Valves organization has established a reputation over many years for fulfilling the needs and requirements of the users of its products. All MAC Valves are quality products specifically designed and built for long and rugged service. Therefore, all valves appearing in this catalog are guaranteed for a period of eighteen months from the original date of shipment from our factory. In addition to this eighteen month Guarantee, MAC Valves, Inc. guarantees the electrical coils on every one of the valves listed in this catalog for life. LIMITATION OF GUARANTEE: This Guarantee is limited to the replacement or rebuilding of any valve which should fail to operate properly. Valves, under the MAC Guarantee, must be returned (with or without bases) transportation prepaid and received at our factory within the Garantee period. They will be returned to the customer at the expense of MAC Valves, Inc., and will carry the same guarantee as provided under the Flat Rate Rebuild Program. DISCLAIMER OF GUARANTEE: No claims for labor, material, time, damage or transportation are allowable nor will any valve be replaced or rebuilt under this guarantee which has been damaged by the purchaser not in the normal course of its use and maintenance during the warranty period. The guarantee does not apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes beyond the control of MAC Valves, Inc. MAC Valves, Inc. shall in no event be liable for remote, special or consequential damages under the MAC Guarantee, nor under any implied warranties, including the implied warranty of merchantability. The above Guarantee is our manner of extending the engineering and service resources of the MAC Valves, Inc. organization to assure our customer long, and continued satisfaction. The flat rate rebuild program Valves no longer covered by the MAC Guarantee can be rebuilt under the Flat Rate Rebuild program. Our constant research and testing program is dedicated to extending the life of our valves and making them even more reliable under the most adverse operating conditions. Valves returned under this program are completely disassembled, inspected, rebuilt to current operating standards wherever possible, tested and returned within a few weeks for a nominal flat rate charge. All rebuilt valves carry for 90 days from date of shipment from our factory the same guarantee as provided for new valves. Pneumatic functions All valves inside the MAC product range allow for multiple pneumatic functions. Direct solenoid and solenoid pilot operated valves could be used as ways, ways (NO, NC) or 4 ways. When plugging one orifice to achieve a way function (or way), it will not affect the valve operation. Direct solenoid valves ways : universal The following functions are available - ways NC - ways NO - ways NC - ways NO - Selector - Divertor Direct solenoid valves 4 ways : The following functions are available - 4 ways - ways NC - ways NO - ways NC - ways NO - Divertor Pilot operated valves ways : The following functions are available - ways NC - ways NO - ways NC - ways NO - Selector : the highest pressure is connected to the IN port; the lowest pressure is connected to the EXH port. (Use external pilot when the highest pressure is less than 5 PSI) - Divertor (consult factory) Pilot operated valves 4 & 5 ways : The following functions are available - 4 or 5 ways - ways NC - ways NO - ways NC - ways NO - Selector (except positions) - Divertor (consult factory). EVERY VALVE FULLY TESTED PRIOR TO SHIPMENT 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section 1 Direct solenoid and solenoid pilot operated valves 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

D i r e c t s o l e n o i d a n d Function Port size Flow (Max) Cv Individual mounting Inline Sub-base non plug-in Sub-base plug-in Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Valve only No base non plug-in Conform to ISO 15407/1 / / - / / / / / / / / / - / / - / / - / 5/ 4/ 4/ 5/ - 5/ 5/ 5/ 5/ 5/ - 5/ 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ 5/ - 5/ M M5 - #10-1/8 1/8 - #10-1/8-5/ 1/8 O.D. pressed-in tube receptacle #10- - 1/4 O.D. tube receptacle 1/8-1/4 1/8-1/4 O.D. tube receptacle 1/8-1/4 /4-1 1 1/ - - 1/ M5 - #10-1/8 - #10- O.D. pressed-in 1/8-5/ tube receptacle #10- - 1/4 O.D. tube receptacle #10- - 1/4 O.D. tube receptacle 1/8-1/4 1/8 1/8 1/8 1/8-1/4 1/8-1/4 - /8 1/4 - /8 /8-1/ 1/4 - /8-1/ 1/4 1/8 1/4 - /8 /8-1/ 1/ - /4 0.08 0.1 0. 0. 0. 0.4 0.4 0.5 1. 1.5 0.0 60.0 0.1 0. 0. 0.4 0.4 0.5 1.0 1.1 1.1 1.0 1. 1..8.4 1.0 0.4 1.8.0 6.1 P. 15 P. 19 P. P. P. 5 P. 41 P. 4 P. 47 P. 49 P. 5 P. 55 P. 59 P. 61 P. 65 P. 69 P. 7 P. 77 P. 81 P. 95 P. 97 P. 111 P. 11 P. 11 P. 15 P. 17 P. 141 P. 14 P. 147 P. 149 P. 159 P. 161 P. 16 P. 10 P. 105 P. 1 P. 15 P. 181 P. 165 P. 187 P. 189 P. 19 P. 195 P. 17 P. 177 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

s o l e n o i d p i l o t o p e r a t e d v a l v e s Manifold mounting Series stacking Manifold base non plug-in Manifold base plug-in Manifold base plug-in with pressure regulators Manifold base plug-in with flow controls Manifold base plug-in with PR & FC Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Valve only No base non plug-in Conform to ISO 15407/1 4 P. 5 P. 7 P. 9 6 P. 8 P. 7 P. 9 P. 41 P. 4 P. 57 P. 55 P. 59 P. 61 P. 85 P. 87 P. 89 P. 91 P. 99 P. 101 P. 115 P. 117 P. 19 P. 11 P. 10 P. 105 P. 1 P. 15 7 8 5 67 69 44 46 4 47 48P 48 400 P. 151 P. 15 P. 165 P. 167 9 9 P. 181 P. 18 P. 187 P. 189 P. 19 P. 195 P.17 P.177 ISO 01 ISO 0 ISO 1 ISO ISO 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves 8mm valve Serie Individual mounting Series Inline 4 6 Ovale armature Encapsulated coil Push pin Bonded balanced poppet 7 8 5 67 69 44 46 4 47 48P 48 Return spring SERIES FEATURES Patented high force MACSOLENOID for fastest possible response times. Bonded balanced poppet for high flow, precise repeatability, and consistent operation. Extremely high cycle rate capability. Use on lube or non-lube service. Low wattage DC solenoids-down to 0.5 W. 8 mm direct operated valve. Very fast response times. 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves 8mm valve Series Function Port size Flow (Max) Individual mounting Series / NC M 0.08 C v Inline OPERATIONAL BENEFITS 1. 8mm valve direct solenoid operated.. Balanced poppet, immune to pressure variations.. Short stroke with high flow. 4. Patented solenoid develops high shifting forces. 5. Low wattage solenoids. 6. Powerful return spring. 7. Extremely fast response times. HOW TO ORDER Port size M ** For use with solenoids above 4.0 W - MOD number required. (Consult factory) SOLENOID OPERATOR N.C. Only A-AAB-RXXX-XXX R XXX-XXX XX Voltage X Lead wire length X Manual operator XX DA DB DC DF DG DH DJ DM 4 VDC (0.5W) 4 VDC (1.0W) 4 VDC (1.8W) 4 VDC (4.0W) 1 VDC (0.5W) 1 VDC (1.0W) 1 VDC (1.8W) 1 VDC (4.0W) * Other options available, see page 1. 0 No Lead wire* A 18 B 4 C 6 D 48 E 7 * Not available for flying leads connectors Washdown capability is possible for the B and R type electrical connectors. Consult factory for ordering information. 0 No manual operator 1 Non-locking recessed Non-locking extended Patents and patents pending N.C. Only ** A-BAB-RXXX-XXX BA BB BC BD RA RB RC RD TA TB TC TD Electrical connection Flying leads Flying leads w/led Flying leads w/mov Flying leads w/led & MOV Mini JAC Solenoid plug-in Mini JAC Solenoid plug-in w/led Mini JAC Solenoid plug-in w/mov Mini JAC Solenoid plug-in w/led & MOV JST Solenoid plug-in JST Solenoid plug-in w/led JST Solenoid plug-in w/mov JST Solenoid plug-in w/led & MOV 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to +50 C) 4W: (Cv.08) - W: (Cv.06) -.5W: (Cv.06) - 1.8W: (Cv.055) - 1.0W: (Cv.00) - 0.5W: (Cv.00) Class A wire (#6 AWG x18), continuous duty -15% to +10% of nominal voltage 4.0W -.0W -.5W - 1.8W - 1.0W - 0.5W DIMENSIONS 5, Dimensions shown are metric (mm) 10,6 4,5 Shown with JST Connector 4,6 4,0 16,0 1,5 1,0 0,,4 8,0 Ø, Thru Typ () 8,00 4,00 7,5 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Individual mounting Series Inline 4 6 Manual operator Armature Coil Push pin 7 8 5 67 69 44 46 4 Poppet D seal Valve spring SERIES FEATURES High force MACSOLENOID. Universal porting. # 10- or M5 ports. Rated for lubricated or non-lubricated service. 10 mm direct operated. 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Individual mounting Series / NO-NC, / NO-NC M5, # 10-0.1 C v Inline OPERATIONAL BENEFITS 1. 10 mm valve, direct solenoid operated.. Balanced poppet, immune to variations of pressure.. Short stroke with high flow. 4. Patented solenoid develops high shifting forces. 5. Powerful return spring. 6. Manual operator standard on all valves. HOW TO ORDER Port size M5 # 10- SOLENOID OPERATOR Universal valve 4C-ABA-G XXX-XXX 4C-AAA-G XXX-XXX 1 G XXX-XXX * XX Voltage X Wire length X Manual operator XX AA DC DD DF 10 VAC (.5W) 4 VDC (1.8W) 4 VDC (.5W) 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 11. A 18 B 4 C 6 Washdown capability is possible for the G type electrical connectors. Consult factory for ordering information. 1 Non-locking recessed Non-locking extended NC only valve 4C-ABB-G XXX-XXX 4C-AAB-G XXX-XXX BA BT GA GB GC GD GE GF GG GH KA KC KT 1 Electrical connection Flying leads Flying leads with light MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly Plug-in wire assembly with rectifier and light Plug-in wire assembly with light 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 4 W : (0.1 C v ).5 W : (0.10 C v ) 1.8 W : (0.06 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 4 W.5 W 1.8 W Energize :.4 ms De-energize : 1.5 ms DIMENSIONS 1,5, DIA. MTG. HOLES () C L C L C L Dimensions shown are metric (mm) 50, 9, 0,0 1,0 4,0 1 4,5 14,5 5, 0,8 5,0 7,0 10,0 10,0 0,0 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 6 Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin Manifold mounting Stacking Manifold base plug-in Manifold base plug-in with pressure regulators 1 4 6 7 8 5 67 69 44 46 4 47 48P Bonded balanced poppet 48 Return spring 400 9 SERIES FEATURES Patented high force MACSOLENOID for fastest possible response times. Bonded balanced poppet for high flow, precise repeatability, and consistent operation. Balanced poppet permits versatility in function may be used as -way or -way normally open or normally closed and may be used for vacuum, divertor, or selector applications. Extremely high cycle rate capability. Use on lube or non-lube service. Manual overrides as standard. Various solenoid enclosures and plug-in connectors. Optional surge suppression available. Low wattage DC solenoids down to 1.8 watts. Rectified AC voltage. 9 ISO 01 ISO 0 ISO 1 ISO ISO 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 6 Function Port size Flow (Max) Individual mounting Series / 1/8 0. C v Inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Universal valve NC only valve 4 6 7 8 5 67 69 44 1/8 NPTF 1 6A-AAA-J XXX-XXX 1 6A-AAB-J XXX-XXX 46 SOLENOID OPERATOR J XXX-XXX * (-G) Add "G" for ground XX Voltage X Lead wire length X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) A 18 B 4 C 6 * Other options available, see page 17. Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. 1 Non-locking recessed Locking recessed BA GA GB GD GG Electrical connection Flying leads MAC JAC solenoid plug-in MAC JAC solenoid plug-in with diode MAC JAC solenoid plug-in with light MAC JAC solenoid plug-in with rectifier 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8 Watt: (0.15 C v ),.4 Watt: (0.15 C v ), 5.4 Watt: (0.0 C v ) Class A wire (# AWG x 1), continuous duty -15% to +10% of nominal voltage Consult factory 5.4 W.4 W 1.8 W Option : BSPP threads DIMENSIONS Dimensions shown are metric (mm). 4. 58. 16.6 1.1 8.0. 10.1 8. 4.5 1.5 Ø.4 15. 0.5 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 6 Function Port size Flow (Max) Individual mounting Series / 1/8" # 10-0. C v Stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # 10- SOLENOID OPERATOR NC only stacking CYL INEXH 6A-SAB-J XXX-XXX 6A-SBB-J XXX-XXX NC stacking Universal poppet CYL IN EXH 6A-SAC-J XXX-XXX 6A-SBC-J XXX-XXX NO stacking Universal poppet CYL IN EXH 6A-SAD-J XXX-XXX 6A-SBD-J XXX-XXX J XXX-XXX * (-G) Add "G" for ground XX Voltage X Lead wire length X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) A 18 B 4 C 6 * Other options available, see page 17. Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. End plate kit required (port size 1/4") : M-6001-01. BODY TYPE OPTIONS 6A-SAB-JXXX-XXX S Stacking body T Stacking body with bottom inlet 1 Non-locking recessed Locking recessed BA GA GB GD GG Electrical connection Flying leads MAC JAC solenoid plug-in MAC JAC solenoid plug-in with diode MAC JAC solenoid plug-in with light MAC JAC solenoid plug-in with rectifier 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8 Watt: (0.15 C v ),.4 Watt: (0.15 C v ), 5.4 Watt: (0.0 C v ) Class A wire (# AWG x 1), continuous duty -15% to +10% of nominal voltage Consult factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet & exhaust isolator plate : N-6001 Inlet isolator : N-600 Exhaust isolator : N-600 Tie rod (x) : 79411 DIMENSIONS 15.0 16.5 8. 15.0 14.1 Dimensions shown are metric (mm) Note: Isolator adds.5 mm to length of stack. 59. 51. 5.. 9.0 5.0 4.7 1/4" COMMONS 9. 86.0 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 6 Function Port size Flow (Max) Individual mounting Series / 1/8" - 5/ Pressed-in 0. C v tube receptacle Manifold base plug-in OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/ tube receptacle SOLENOID OPERATOR Universal Valve Normally Closed 6A-J00-00-J XXP-XXX 6A-JSA-AE-J XXP-XXX 6A-JSF-AE-J XXP-XXX 1 J XX P-XXX * Universal Valve Normally Open 6A-K00-00-J XXP-XXX 6A-KSA-AF-J XXP-XXX 6A-KSF-AF-J XXP-XXX 1 Normally Closed Only 6A-L00-00-J XXP-XXX 6A-LSA-AE-J XXP-XXX 6A-LSF-AE-J XXP-XXX (-G) Add G for ground 1 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. 1 Non-locking recessed Locking recessed Example : Manifold base only : 6A-0SA-AE (Normally closed manifold base). End plate kit required (port size 1/4") : M-4600-01. FA FB FG Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult Factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 DIMENSIONS 18.6 16.5 8.0 Dimensions shown are metric (mm) 8.0 4.0 Note: For Normally closed manifold the A port is plugged. For Normally open manifold the B port is plugged. 78.0 4.4 94. Ø 4. 1/4" COMMONS.8.5 9.5 4.0 19.0 4. 5.5 79.0 95.5 /4"-14 NPSM 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 6 Function Port size Flow (Max) Individual mounting Series / 1/8" - 5/ Pressed-in 0. C v tube receptacle OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/ tube receptacle SOLENOID OPERATOR Universal Valve Normally Closed 6A-J00-00-J XXP-XXX 6A-JSA-AG-J XXP-XXX 6A-JSF-AG-J XXP-XXX 1 J XX P-XXX * Universal Valve Normally Open 6A-K00-00-J XXP-XXX 6A-KSA-AH-J XXP-XXX 6A-KSF-AH-J XXP-XXX 1 Manifold base plug-in with pressure regulators Normally Closed Only 6A-L00-00-J XXP-XXX 6A-LSA-AG-J XXP-XXX 6A-LSF-AG-J XXP-XXX (-G) Add G for ground 1 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. 1 Non-locking recessed Locking recessed FA FB FG Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 OPTIONS 6A-JSA-AG-JXX P-XXX G NC manifold & regulator with slotted stem adjustment 6A-KSA-AH-JXX P-XXX H NO manifold & regulator with slotted stem adjustment S NC manifold & regulator with locking slotted stem adjustment T NO manifold & regulator with locking slotted stem adjustment J NC manifold & regulator with knob adjustment K NO manifold & regulator with knob adjustment Note : All manifold bases are only available with a bottom cylinder port. Example : Manifold base only : 6A-0SA-AJ (Normally closed manifold base & regulator with knob). End plate kit required (port size 1/4") : M-4600-01. 9 ISO 01 ISO 0 ISO 1 ISO ISO 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult Factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 DIMENSIONS 18.6 16.5 Dimensions shown are metric (mm) Note: For Normally closed manifold the A port is plugged. For Normally open manifold the B port is plugged. 78.0.8 4.4 94..5 9.5 1/8" GAGE PORT 69. Ø 4. 1/4" COMMONS 7.9 4.0 5.5 19.0 4. 47.6.6 79.0 95.5 /4"-14 NPSM 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Individual mounting Sub-base non plug-in Sub-base plug-in Manifold mounting Manifold base non plug-in Manifold base plug-in Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Integral 4-way pilot Series 4 6 7 8 5 67 69 44 46 Manual operator Solenoid SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. Internal or external pilot. Normally open or normally closed function. Universal function (external pilot). Rectified AC voltage. Latching solenoid technology. Bonded spool 1 Air return 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual mounting Series / NO-NC 1/8 0.4 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External B-BMA-000-GXXX-XXX B-BMB-000-GXXX-XXX B-BMA-CAL-GXXX-XXX B-BMB-CAM-GXXX-XXX B-AMA-000-GXXX-XXX B-AMB-000-GXXX-XXX B-AMA-CAL-GXXX-XXX B-AMB-CAM-GXXX-XXX G XXX-XXX * Universal valve 10 1 1 B-GMB-000-GXXX-XXX B-GMB-CAM-GXXX-XXX 7 8 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DA 4 VDC (1.0W) B 4 Locking recessed BT DC 4 VDC (1.8W) C 6 GA DD 4 VDC (,5W) GB DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. GC * Other options available, see page 11. Latching solenoid also available, see page 41. GD With MAC JAC electrical connector washdown capability is possible. Consult factory for modification number. GE OPTIONS Pilot/Base Configuration : B-XMX-XAX-GXXX-XXX A Individual base Side port B Individual base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust (not available with external pilot) GF GG GH KA KT KD Electrical connection Flying leads Flying leads with light MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8 : (0.40 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 6.0 4.5 X 1 67.4 79.1 Ø 4. 49.9 7. 4.7 8.0 4.0 6.0 8.0.1 6.0 1.8 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual mounting Series / NO-NC # 10- - 0.4 C v 1/4 O.D. tube receptacle Sub-base plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base # 10-1/4 O.D. Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External B-BMA-000-GXXP-XXX B-BMB-000-GXXP-XXX B-BMA-AAA-GXXP-XXX B-BMB-AAB-GXXP-XXX B-BMA-EAA-GXXP-XXX B-BMB-EAB-GXXP-XXX B-AMA-000-GXXP-XXX B-AMB-000-GXXP-XXX B-AMA-AAA-GXXP-XXX B-AMB-AAB-GXXP-XXX B-AMA-EAA-GXXP-XXX B-AMB-EAB-GXXP-XXX G XX P-XXX * Universal valve 10 1 1 B-GMB-000-GXXP-XXX B-GMB-AAB-GXXP-XXX B-GMB-EAB-GXXP-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Manual operator XX AA 10 VAC (.5W) 1 Non-locking recessed SA DA 4 VDC (1.0W) Locking recessed SJ DC 4 VDC (1.8W) SS DD 4 VDC (.5W) DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 11. Latching solenoid also available, see page 4. Washdown capability is possible, consult factory for modification number. OPTIONS Pilot/Base Configuration : B-XMX-XAX-GXX P-XXX A Individual base Side port B Individual base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust (not available with external pilot) Electrical connection Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

X 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) - 1/4 tube receptacle : (0.40 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 port M7 port 6 mm O.D. tube receptacle DIMENSIONS Dimensions shown are metric (mm) 1"-11 1/ CONDUIT 1/8" EXTERNAL PILOT 114.0 94.0 68.4 #10- PORT SHOWN 56.7. 5.0 5.5 18.5 1/4" IN & EXH COMMONS 9.5 11.1 0.0.0 Ø 5. 10 4.8.7. 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual mounting Series / NO-NC # 10- - 0.4 C v 1/4 O.D. tube receptacle Manifold base non plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base # 10-1/4 O.D. Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External B-BMA-000-GXXX-XXX B-BMB-000-GXXX-XXX B-BMA-AJL-GXXX-XXX B-BMB-AJM-GXXX-XXX B-BMA-EJL-GXXX-XXX B-BMB-EJM-GXXX-XXX B-AMA-000-GXXX-XXX B-AMB-000-GXXX-XXX B-AMA-AJL-GXXX-XXX B-AMB-AJM-GXXX-XXX B-AMA-EJL-GXXX-XXX B-AMB-EJM-GXXX-XXX G XXX-XXX * Universal valve 10 1 1 B-GMB-000-GXXX-XXX B-GMB-AJM-GXXX-XXX B-FMB-EJM-GXXX-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DA 4 VDC (1.0W) B 4 Locking recessed BT DC 4 VDC (1.8W) C 6 GA DD 4 VDC (.5W) GB DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. GC * Other options available, see page 11. Latching solenoid also available, see page 41. GD With MAC JAC electrical connector washdown capability is possible. Consult factory for modification number. GE Base only : OPTIONS B-000-XXX (i.e. B-000-AJL) Base/Pilot Configuration : B-XMX-XJX-GXXX-XXX J Manifold base Side port K Manifold base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust (not available with external pilot) GF GG GH KA KT KD Electrical connection Flying leads Flying leads with light MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Note : Manifold assemblies require an end plate kit : M-00-01-01 (Internal pilot) M-00-0-01 (External pilot) 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) - 1/4 tube receptacle : (0.40 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 port M7 port 6 mm O.D. tube receptacle Inlet/Exhaust Isolator : 8454 DIMENSIONS Dimensions shown are metric (mm) 1/8" EXTERNAL PILOT X 79.1 1 99.9 70.4 56.7 9.6. 5.0 10.5 18.5 9.5 1/4" IN & EXH COMMONS 4. 11.1 0.4 Ø 5. M7 PORTS SHOWN 76.5 5.5 4. 10.5 9.6 19.0 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual mounting Series / NO-NC # 10- - 0.4 C v 1/4 O.D. tube receptacle Manifold base plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base # 10-1/4 O.D. Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External B-BMA-000-GXXP-XXX B-BMB-000-GXXP-XXX B-BMA-AJA-GXXP-XXX B-BMB-AJB-GXXP-XXX B-BMA-EJA-GXXP-XXX B-BMB-EJB-GXXP-XXX B-AMA-000-GXXP-XXX B-AMB-000-GXXP-XXX B-AMA-AJA-GXXP-XXX B-AMB-AJB-GXXP-XXX B-AMA-EJA-GXXP-XXX B-AMB-EJB-GXXP-XXX G XX P-XXX * Universal valve 10 1 1 B-GMB-000-GXXP-XXX B-GMB-AJB-GXXP-XXX B-GMB-EJB-GXXP-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Manual operator XX AA 10 VAC (.5W) 1 Non-locking recessed SA DA 4 VDC (1.0W) Locking recessed SJ DC 4 VDC (1.8W) SS DD 4 VDC (.5W) DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 11. Latching solenoid also available, see page 4. Washdown capability is possible, consult factory for modification number. Base only : OPTIONS B-000-XXX (i.e. B-000-AJA) Base Configuration : B-XXX-XJX-GXX P-XXX J Manifold base Side port K Manifold base Bottom port L Left end manifold base Side port M Left end manifold base Bottom port N Right end manifold base Side port P Right end manifold base Bottom port Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold and middle station manifolds (options "J" or "K"). Electrical connection Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

X 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) - 1/4 tube receptacle : (0.40 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 port M7 port 6 mm O.D. tube receptacle Inlet/Exhaust Isolator : 8454 DIMENSIONS 1"-11 1/ CONDUIT Dimensions shown are metric (mm) 1/8" EXTERNAL PILOT 114.0 94.0 68.4 9.6 56.7. 5.0 10 10 10 10 10.5 18.5 9.5 11.1 0.0 Ø 5. 4. 1/4" IN & EXH COMMONS.0 66.5 #10- PORT SHOWN.7 10.5 18.5 40 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual mounting Series / NO-NC # 10- - 0.4 C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Sub-base/ manifold base non plug-in with latching solenoid 4 6 HOW TO ORDER Port size Valve less base Pilot air Internal NO valve 10 1 1 A-BMA-000-LXXX-XXX NC valve 10 1 1 A-AMA-000-LXXX-XXX 7 8 5 67 69 44 46 External # 10- Internal External 1/4 O.D. Internal Tube receptacle External Note : Above codes are for individual base and side port. LATCHING SOLENOID OPERATOR A-BMB-000-LXXX-XXX A-BMA-AAL-LXXX-XXX A-BMB-AAM-LXXX-XXX A-BMA-EAL-LXXX-XXX A-BMB-EAM-LXXX-XXX L XXX-XXX * A-AMB-000-LXXX-XXX A-AMA-AAL-LXXX-XXX A-AMB-AAM-LXXX-XXX A-AMA-EAL-LXXX-XXX A-AMB-EAM-LXXX-XXX 4 47 48P 48 XX Voltage X Wire length X Manual operator XX DF 4 VDC (4.0W) A 18 0 No operator BA HA 4 VDC (1.95W) B 4 BJ C 6 KA KE LA * Other options available, see page 19. ** Latching series with non plug-in base configuration must use "B", "K" or "L" type electrical connector. OPTIONS Pilot/Base Configuration : A-XMX-XAX-LXXX-XXX A Individual base Side port B Individual base Bottom port J Manifold base Side port K Manifoldl base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust (not available with external pilot) Note : Manifold assemblies require an end plate kit: M-00-01-01 (internal pilot) M-00-0-01 (external pilot) Electrical connection** Wire Flying leads 4 Wire Flying leads Wire Plug-in Assembly 4 Wire Plug-in Assembly Wire plug-in assembly (Polarity Switching Cover) 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 41 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) - 1/4 tube receptacle : (0.40 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 port M7 port 6 mm O.D. tube receptacle DIMENSIONS Dimensions shown are metric (mm) 1/8" EXTERNAL PILOT X 79.1 70.4 56.7 1 108.5 9.6. 10.5 18.5 9.5 11.1 0.4 1/4" IN & EXH COMMONS Ø 5. 4. 5.0 M7 PORT SHOWN 76.5 5.5 19.0 10.5 4. 9.6 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series Function Port size Flow (Max) Individual/Manifold mounting Series / NO-NC # 10- - 0.4 C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Sub-base/ manifold base plug-in with latching solenoid 4 6 HOW TO ORDER Port size Valve less base Pilot air Internal NO valve 10 1 1 A-BMA-000-LXXP-XXX NC valve 10 1 1 A-AMA-000-LXXP-XXX 7 8 5 67 69 44 46 External # 10- Internal External 1/4 O.D. Internal Tube receptacle External Note : Above codes are for individual base and side port. A-BMB-000-LXXP-XXX A-BMA-AAA-LXXP-XXX A-BMB-AAB-LXXP-XXX A-BMA-EAA-LXXP-XXX A-BMB-EAB-LXXP-XXX A-AMB-000-LXXP-XXX A-AMA-AAA-LXXP-XXX A-AMB-AAB-LXXP-XXX A-AMA-EAA-LXXP-XXX A-AMB-EAB-LXXP-XXX 4 47 48P LATCHING SOLENOID OPERATOR L XX P-XXX * 48 XX Voltage X Manual operator XX DF 4 VDC (4.0W) 0 No operator DA HA 4 VDC (1.95W) DB DC DD EA * Other options available, see page 19. ** and 4 wire base must use "D" type electrical connector, wire base must use "EA" type electrical connector. OPTIONS Pilot/Manifold/Base Configuration : A-XMX-XAX-LXXP-XXX A Individual base Side port B Individual base Bottom port J Manifold base Side port K Manifold base Bottom port L Left end manifold base Side port M Left end manifold base Bottom port N Right end manifold base Side port P Right end manifold base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (#10-) U Pilot exhaust to main exhaust (not available with external pilot) Manifold/Base Int./Ext. Pilot : (wire options) A-XMX-XXA-LXXP-XXX Electrical connection** Base/Manifold Plug-in Base/Manifold Plug-in w/ground Base/Manifold Plug-in w/ Light Base/Manifold Plug-in w/ Light and Ground Base/Manifold Plug-in Pin (Polarity Switching Cover) A Plug-In Int. Pilot ( Wire)** B Plug-In Ext. Pilot ( Wire)** C Plug-In Int. Pilot ( Wire)** D Plug-In Ext. Pilot ( Wire)** E Plug-In Int. Pilot (4 Wire)** F Plug-In Ext. Pilot (4 Wire)** 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (option J or K). 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

X 1 X 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) - 1/4 tube receptacle : (0.40 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 port M7 port 6 mm O.D. tube receptacle 1"-11 1/ CONDUIT 1/8" EXTERNAL PILOT DIMENSIONS Individual base Dimensions shown are metric (mm) Manifold base 1"-11 1/ CONDUIT 1/8" EXTERNAL PILOT 114.0 94.0 94.0 68.4 68.4 9.6 56.7 56.7. 1/4" IN & EXH COMMONS 9.5 11.1 0.0.0 Ø 5. 10 4.8 5.0 10.5 18.5 1/4" IN & EXH COMMONS. 9.5 11.1 0.0.0 66.5 114.0 #10- PORTS SHOWN #10- PORTS SHOWN 5.5 18.5.7. Ø 5. 10 10 10 10 4. 5.0.7 10.5 18.5 44 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 7 Individual mounting Series Inline Sub-base non plug-in 4 6 Manual operator Armature Coil Push pin Pole piece D seal 1 7 8 5 67 69 44 46 4 47 48P Poppet 48 Valve return spring 400 9 SERIES FEATURES Balanced poppet equals consistent high shifting forces. Valve shifting forces are consistent and independent of pressure fluctuations. High solenoid and return spring forces ensure high speed and precise repeatability. Built-in wear compensation - valve stroke is shorter than solenoid stroke. Constant high flow maintained throughout the pressure range. Exhaust contaminants are isolated from the solenoid. Full flow exhaust. Universal porting - 6 functions in one valve. 9 ISO 01 ISO 0 ISO 1 ISO ISO 45 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 7 Function Port size Flow (Max) Individual mounting Series / NO-NC 1/8-1/4 0.5 C v Inline OPERATIONAL BENEFITS 1. Balanced poppet equals consistent high shifting forces.. Valve shifting forces are consistent and independent of pressure fluctuations.. High solenoid and return spring forces ensure high speed and precise repeatability. 4. Built-in wear compensation valve stroke is shorter than solenoid stroke. 5. Constant high flow maintained throughout the pressure range. 6. Exhaust contaminants are isolated from the solenoid. 7. Full flow exhaust. 8. Universal porting 6 functions in one valve. HOW TO ORDER Port size 1/8 NPTF 1/4 NPTF SOLENOID OPERATOR Universal valve 7A-AA0-H XXX-XXX 7A-AB0-H XXX-XXX 1 H XXX-XXX * XX Voltage X Wire length X Manual operator XX AA DA DB DC 10 VAC (6.7W) 4 VDC (5.W) 4 VDC (.4W) 4 VDC (1.8W) Note : AC voltage requires connector with rectifier. * Other options available, see page 15. A 18 B 4 1 Non-locking recessed Locking recessed NC only valve 7A-BA0-H XXX-XXX 7A-BB0-H XXX-XXX MA MC BA BC MT 1 Electrical connection** Plug-in wire assembly Plug-in wire assembly with light Flying leads Flying leads with light Plug-in wire assembly with rectifier & light 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 47 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 7 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5. W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5. W : (0.5 C v ).4 W : (0.5 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 5. W.4 W Energize : 16.9 ms De-energize : 6.7 ms Options : BSPP ports DIMENSIONS Dimensions shown are metric (mm).0 4.5 DIA. MTG. HOLES () 18.0 9.0.7 7. 6.0 () 67.4 A 1 10 6.0 9.0 () 1 97.5 B Shown with Mini Square Connector ( K Type) Dim A B 1/8 1/4 1. 14.7.45.7 48 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 7 Function Port size Flow (Max) Individual mounting Series / NO-NC 1/8-1/4 0.5 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. Balanced poppet equals consistent high shifting forces.. Valve shifting forces are consistent and independent of pressure fluctuations.. High solenoid and return spring forces ensure high speed and precise repeatability. 4. Built-in wear compensation valve stroke is shorter than solenoid stroke. 5. Constant high flow maintained throughout the pressure range. 6. Exhaust contaminants are isolated from the solenoid. 7. Full flow exhaust. 8. Universal porting 6 functions in one valve. HOW TO ORDER Port size Universal valve NC only valve 4 6 7 8 5 67 69 44 Valve less base 1 7A-C10-H XXX-XXX 1 7A-D10-H XXX-XXX 46 1/8 NPTF 1/4 NPTF 7A-CAA-H XXX-XXX 7A-CBA-H XXX-XXX 7A-DAA-H XXX-XXX 7A-DBA-H XXX-XXX 4 SOLENOID OPERATOR H XXX-XXX * 47 48P XX Voltage X Wire length X Manual operator XX AA DA DB DC 10 VAC (6.7W) 4 VDC (5.W) 4 VDC (.4W) 4 VDc (1.8W) Note : AC voltage requires connector with rectifier. * Other options available, see page 15. OPTIONS Base only : 7A-0AA (1/8 ) 7A-0BA (1/4 ) A 18 B 4 1 Non-locking recessed Locking recessed MA MC BA BC MT Electrical connection Plug-in wire assembly Plug-in wire assembly with light Flying leads Flying leads with light Plug-in wire assembly with rectifier & light 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 49 Consult Precautions page 7 before use, installation or service of MAC Valves..

G + - 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 7 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5. W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5. W : (0.5 C v ).4 W : (0.5 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 5. W.4 W Energize : 16.9 ms De-energize : 6.7 ms Options : BSPP ports Sandwich regulator - see Regulator Section DIMENSIONS Dimensions shown are metric (mm) 100.5 APPROX 98.4 APPROX E 4.0 DIA. () HOLES 5.0 A F 46.5 1 1 19.00 B C 10 10 7.9 APPROX 8.10 8.1 5.0 D PLUG-IN OPTION (SHOWN WITH 1/8" PORTS) 19.5 WIDE VALVE BODY CIRCUIT BOARD OPTION (SHOWN WITH 1/4" PORTS) 17.5 & 19.5 WIDE VALVE BODIES FLYING LEAD OPTION (SHOWN WITH 1/8" PORTS) 17.5 WIDE VALVE BODY 100.6 APPROX L 4.5 4.0 DIA. () HOLES G 84. APPROX 10.8 APPROX M 46.5 1 1 1 7.00 H J Dim A B C D E F G H J K L M 54.6 APPROX 69.9 APPROX 10 8.10 8.1 10 5.0 K 1/8 1/4 8.0 9.5 1.0 9.5 5.5 19.05 8.0 9.5 4.0.5 8.0 9.5 15.1 18.0 4.0 7.0 19.05 8.0 9.5. 4.0 50 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Manual operator Solenoid Individual mounting Sub-base non plug-in Sub-base plug-in Manifold mounting Manifold base plug-in Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Integral 4-way pilot Series 4 6 7 8 5 67 69 44 46 4 47 48P SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. Internal or external pilot. Normally open or normally closed function. Universal function (external pilot). Rectified AC voltage. Latching solenoid technology. Bonded spool 1 Air return 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 51 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Function Port size Flow (Max) Individual mounting Series / NO-NC 1/8 1. C v Sub-base non plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 16.5 mm centers).. High flow (up to 1. Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF OPTIONS 8B-XMX-XAX-GXXX-XXX Pilot air Internal External Internal External Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot/Base Configuration : A Individual base Side port B Individual base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust 10 NO valve 1 8B-BMA-000-GXXX-XXX 8B-BMB-000-GXXX-XXX 8B-BMA-AAL-GXXX-XXX 8B-BMB-AAM-GXXX-XXX G XXX-XXX * NC valve 8B-AMA-000-GXXX-XXX 8B-AMB-000-GXXX-XXX 8B-AMA-AAL-GXXX-XXX 8B-AMB-AAM-GXXX-XXX XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DA 4 VDC (1.0W) B 4 Locking recessed BT DC 4 VDC (1.8W) C 6 GA DD 4 VDC (.5W) GB DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. GC * Other options available, see page 11. Latching solenoid also available, see page 59. GD With MAC JAC electrical connector washdown capability is possible. Consult factory for modification number. GE 1 10 1 1 GF GG GH KA KT KD Universal valve 10 1 1 8B-GMB-000-GXXX-XXX 8B-GMB-AAM-GXXX-XXX Electrical connection Flying leads Flying leads with light MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly Plug-in wire assembly with light Plug-in wire assembly with rectifier & light & ground 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 8 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" bottom port: (1. C v ) - 1/8" side port: (1.0 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 86.0 EP MODEL 97.6 44. 1 P 8.0 WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 116.9 46.4 8.4 9.7 10 8.0. 1.5 19.0 1.0 4.8 4. 16.6 Ø 5. 4. 54 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Function Port size Flow (Max) Individual mounting Series / NO-NC 1/8-1. C v 1/4 O.D. tube receptacle Sub-base plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 16.5 mm centers).. High flow (up to 1. C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF 1/4 O.D. Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External 8B-BMA-000-GXXP-XXX 8B-BMB-000-GXXP-XXX 8B-BMA-AAA-GXXP-XXX 8B-BMB-AAB-GXXP-XXX 8B-BMA-EAA-GXXP-XXX 8B-BMB-EAB-GXXP-XXX 8B-AMA-000-GXXP-XXX 8B-AMB-000-GXXP-XXX 8B-AMA-AAA-GXXP-XXX 8B-AMB-AAB-GXXP-XXX 8B-AMA-EAA-GXXP-XXX 8B-AMB-EAB-GXXP-XXX G XX P-XXX * Universal valve 10 1 1 8B-GMB-000-GXXP-XXX 8B-GMB-BAB-GXXP-XXX 8B-GMB-EAB-GXXP-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Manual operator XX AA 10 VAC (.5W) 1 Non-locking recessed SA DA 4 VDC (1.0W) Locking recessed SJ DC 4 VDC (1.8W) SS DD 4 VDC (.5W) DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 11. Latching solenoid also available, see page 61. OPTIONS Pilot/Base Configuration : 8B-XMX-XAX-GXX P-XXX A Individual base Side port B Individual base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust Electrical connection Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Washdown capability is possible, consult factory for modification number. 55 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 8 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" bottom port: (1. C v ) - 1/8" side port: (1.0 C v ) - 1/4 tube receptacle: (0.85 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) MODEL 76.0 11.0 115.8 WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI 8.0 50.4. 1.5 9.7 4.0 6.4 56 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Function Port size Flow (Max) Manifold mounting Series / NO-NC 1/8-1. C v 1/4 O.D. tube receptacle Manifold base plug-in OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 16.5 mm centers).. High flow (up to 1. C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF 1/4 O.D. Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External 8B-BMA-000-GXXP-XXX 8B-BMB-000-GXXP-XXX 8B-BMA-AJA-GXXP-XXX 8B-BMB-AJB-GXXP-XXX 8B-BMA-EJA-GXXP-XXX 8B-BMB-EJB-GXXP-XXX 8B-AMA-000-GXXP-XXX 8B-AMB-000-GXXP-XXX 8B-AMA-AJA-GXXP-XXX 8B-AMB-AJB-GXXP-XXX 8B-AMA-EJA-GXXP-XXX 8B-AMB-EJB-GXXP-XXX G XX P-XXX * Universal valve 10 1 1 8B-GMB-000-GXXP-XXX 8B-GMB-BJB-GXXP-XXX 8B-GMB-EJB-GXXP-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Manual operator XX AA 10 VAC (.5W) 1 Non-locking recessed SA DA 4 VDC (1.0W) Locking recessed SJ DC 4 VDC (1.8W) SS DD 4 VDC (.5W) DF 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 11. Latching solenoid also available, see page 61. Washdown capability is possible, consult factory for modification number. Base only : OPTIONS 8B-000-XXX (i.e. 8B-000-AJA) Base Configuration : 8B-XXX-XJX-GXX P-XXX J Manifold base Side port K Manifold base Bottom port L Left end manifold base Side port M Left end manifold base Bottom port N Right end manifold base Side port P Right end manifold base Bottom port Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold and middle station manifolds (options "J" or "K"). Electrical connection Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 57 Consult Precautions page 7 before use, installation or service of MAC Valves..

1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 8 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" bottom port: (1. C v ) - 1/8" side port: (1.0 C v ) - 1/4 tube receptacle: (0.85 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 4.0 1/8" COMMON EXT. PILOT COND 55.5 /4"-14 CONDUIT 11.0 MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 115.8 EP 107.1 8. 7.7 9.7 51.5 8.4. 16.5 Ø 5. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 1.0 16.7 9.5.5 47.5 /8" IN & EXH 76.0 8.0 1.5 16.5. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 58 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Function Port size Flow (Max) Individual/Manifold mounting Series / NO-NC 1/8-1. C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 16.5 mm centers).. High flow (up to 1. C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Sub-base/ manifold base non plug-in with latching solenoid 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF 1/4 O.D. Tube receptacle Note : Above codes are for individual base and side port. LATCHING SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External 8A-BMA-000-LXXX-XXX 8A-BMB-000-LXXX-XXX 8A-BMA-AAL-LXXX-XXX 8A-BMB-AAM-LXXX-XXX 8A-BMA-EAL-LXXX-XXX 8A-BMB-EAM-LXXX-XXX 8A-AMA-000-LXXX-XXX 8A-AMB-000-LXXX-XXX 8A-AMA-AAL-LXXX-XXX 8A-AMB-AAM-LXXX-XXX 8A-AMA-EAL-LXXX-XXX 8A-AMB-EAM-LXXX-XXX L XXX-XXX * Universal valve 10 1 1 8A-GMB-000-LXXX-XXX 8A-GMB-AAM-LXXX-XXX 8A-GMB-EAM-LXXX-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Wire length X Manual operator XX DF 4 VDC (4.0W) A 18 0 No operator BA HA 4 VDC (1.95W) B 4 BJ C 6 KA KE LA * Other options available, see page 19. ** Latching 8 series with non plug-in base configuration must use "B", "K" or "L" type electrical connector. OPTIONS Pilot/Base Configuration : 8A-XMX-XAX-LXXX-XXX A Individual base Side port B Individual base Bottom port J Manifold base Side port K Manifoldl base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (#10-) U Pilot exhaust to main exhaust Electrical connection** Wire Flying leads 4 Wire Flying leads Wire Plug-in Assembly 4 Wire Plug-in Assembly Wire plug-in assembly (Polarity Switching Cover) 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Note : Manifold assemblies require an end plate kit : M-800-01-01 (internal pilot) M-800-0-01 (external pilot) 59 Consult Precautions page 7 before use, installation or service of MAC Valves..

1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 8 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" bottom port: (1. C v ) - 1/8" side port: (1.0 C v ) - 1/4 tube receptacle: (0.85 C v ) Class A wires (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads DIMENSIONS Individual base Manifold base 86.0 1/8" COMMON EXT. PILOT 47.5 EP EP 97.6 1 MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. 15.5 51.4 8. 7.7 P 44. P 8.0 MODIF. VAC TO 150 PSI 15.5 8.4 8.4 46.4 7. 16.5 1.0 Ø 5. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 16.7 9.5 47.5 /8" IN & EXH 9.7 10 1.0 4.8 4. 16.6 Ø 5. 4. 76.0 MODEL MODEL MODEL MODEL 46. WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 8.0 7. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 16.5 19.0 8.0 4. 4.. 1.5 19.0 60 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 8 Function Port size Flow (Max) Individual/Manifold mounting Series / NO-NC 1/8-1. C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. -way valve with 4-way integral pilot.. 10 mm valve (stacks on 16.5 mm centers).. High flow (up to 1. C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Sub-base/ manifold base plug-in with latching solenoid 4 6 HOW TO ORDER Port size Valve less base 1/8 NPTF 1/4 O.D. Tube receptacle Note : Above codes are for individual base and side port. LATCHING SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 1 1 Internal External Internal External Internal External 8A-BMA-000-LXXP-XXX 8A-BMB-000-LXXP-XXX 8A-BMA-AAA-LXXP-XXX 8A-BMB-AAB-LXXP-XXX 8A-BMA-EAA-LXXP-XXX 8A-BMB-EAB-LXXP-XXX 8A-AMA-000-LXXP-XXX 8A-AMB-000-LXXP-XXX 8A-AMA-AAA-LXXP-XXX 8A-AMB-AAB-LXXP-XXX 8A-AMA-EAA-LXXP-XXX 8A-AMB-EAB-LXXP-XXX L XX P-XXX * Universal valve 10 1 1 8A-GMB-000-LXXP-XXX 8A-GMB-AAB-LXXP-XXX 8A-GMB-EAB-LXXP-XXX 7 8 5 67 69 44 46 4 47 48P 48 XX Voltage X Manual operator XX DF 4 VDC (4.0W) 0 No operator DA HA 4 VDC (1.95W) DB DC DD EA * Other options available, see page 19. ** and 4 wire bases must use "D" type electrical connector. wire base must use "EA" type electrical connector. OPTIONS Manifold/Base Configuration : 8A-XXX-XAX-LXXP-XXX A Individual base Side port B Individual base Bottom port J Manifold base Side port K Manifold base Bottom port L Left end manifold base Side port M Left end manifold base Bottom port N Right end manifold base Side port P Right end manifold base Bottom port Manifold/Base Int./Ext. Pilot : (Wire options) 8A-XXX-XXA-LXXP-XXX Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (option J or K). Electrical connection** Base/Manifold Plug-in Base/Manifold Plug-in w/ground Base/Manifold Plug-in w/ Led Base/Manifold Plug-in w/ Led and Ground Base/Manifold Plug-in Pin (Polarity Switching Cover) A Plug-In Int. Pilot ( Wire)** B Plug-In Ext. Pilot ( Wire)** C Plug-In Int. Pilot ( Wire)** D Plug-In Ext. Pilot ( Wire)** E Plug-In Int. Pilot (4 Wire)** F Plug-In Ext. Pilot (4 Wire)** 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 61 Consult Precautions page 7 before use, installation or service of MAC Valves..

1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 8 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" bottom port: (1. C v ) - 1/8" side port: (1.0 C v ) - 1/4 tube receptacle: (0.85 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads DIMENSIONS Individual base Manifold base Dimensions shown are metric (mm) 1/8" COMMON EXT. PILOT COND 55.5 /4"-14 CONDUIT EP 107.1 8. 7.7 11.0 115.8 MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 76.0 51.5. 16.5 Ø 5. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 8.4 1.0 16.7 9.5.5 47.5 /8" IN & EXH 50.4 4.0 9.7 8.0 76.0 4.0 6.4. 1.5 11.0 MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 115.8 8.0 1.5 16.5. 1/8" TAPPED OR 1/4" O.D. TUBE FITTING 9.7 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 5 Individual mounting Series Inline Bonded spool Air return Manual operator Solenoid 4-way pilot with balanced poppet 4 6 7 8 5 67 69 44 46 4 47 48P 1 48 400 9 SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Various manual operators. Optional memory spring. Normally closed or normally open valve function. May be plugged for -way operation. Internal or external pilot. 9 ISO 01 ISO 0 ISO 1 ISO ISO 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 5 SPOOL CONFIGURATIONS INTERNAL PILOT 10 1 INTERNAL PILOT 10 1 1 NORMALLY CLOSED WAY 1 NORMALLY OPEN WAY 64 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 5 Function Port size Flow (Max) Individual mounting Series / NO-NC, / NO-NC 1/8-1/4 1.5 C v Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Port size 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF Pilot air Internal External SOLENOID OPERATOR 10 NO Valve 1 1 5A-1-A0A-XX-X-XXX-XXX 5A-1-B0A-XX-X-XXX-XXX 5A-1-A0B-XX-X-XXX-XXX 5A-1-B0B-XX-X-XXX-XXX Single Operator 10 NC Valve 1 1 5A-11-A0A-XX-X-XXX-XXX 5A-11-B0A-XX-X-XXX-XXX 5A-11-A0B-XX-X-XXX-XXX 5A-11-B0B-XX-X-XXX-XXX DM-D XXX-XXX * Double Operator NO Valve NC Valve 10 1 10 1 1 1 5A-41-A0A-XX-X-XXX-XXX 5A-1-A0A-XX-X-XXX-XXX 5A-41-B0A-XX-X-XXX-XXX 5A-1-B0A-XX-X-XXX-XXX 5A-41-A0B-XX-X-XXX-XXX 5A-1-A0B-XX-X-XXX-XXX 5A-41-B0B-XX-X-XXX-XXX 5A-1-B0B-XX-X-XXX-XXX 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 (.9W) A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) B 4 (Flying leads) Locking recessed KD JC 4/60 (.9W) J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) DF 4 VDC (1.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** XX Voltage X Wire length X Manual operator XX DC 4 VDC (1.8W) A 18 1 Non-locking recessed BA DD 4 VDC (.5W) B 4 Locking recessed BT DF 4 VDC (4.0W) C 6 KA * Other options available, see page 09. KT ** Other options available, see page 1. OPTIONS 5A-1-A0A-XX-X-XXX-XXX For memory spring, replace by 4 (single solenoid only) Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 65 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 5 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" : (1. C v ) 1/4" : (1.5 C v ) Class A continuous duty, # AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory ~Inrush: 10.9 VA Holding: 7.7 VA = 1.8 to 1.7 W 4V=/5.4W Energize: 7. ms De-energize: 5. ms 10/60 Energize: 8-1 ms De-energize: 7-11 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) #10- OR M5 (OPTIONAL EXTERNAL PILOT PORT) 4,5 1,0,5 DIA. THR U, () 79,0 4,0 44,0 17,0 7,0 1,0 5,0 () 1,6 15,5 6,5 4,5 66 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 67 Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Inlet (1) Exhaust () Cylinder () 4 6 7 8 5 67 69 44 46 4 47 48P SERIES FEATURES Bonded spool Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Normally closed or normally open valve function. Optional universal spool. Internal or external pilot. Optional memory spring. Checked accumulator. Optional pilot exhaust to main valve exhaust. May be plugged for -way operation. Air return 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 67 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 67 Function Port size Flow (Max) Individual mounting Series / NO-NC, / NO-NC /4-1 0.0 C v Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. HOW TO ORDER Port size /4 NPTF 1 NPTF /4 NPTF 1 NPTF Pilot air Internal External SOLENOID OPERATOR 10 NO Valve 1 1 67A-CX-AAA-DM-DXXX-XXX 67A-CX-BAA-DM-DXXX-XXX 67A-CX-AAB-DM-DXXX-XXX 67A-CX-BAB-DM-DXXX-XXX Single Operator 10 NC Valve 1 1 67A-AX-AAA-DM-DXXX-XXX 67A-AX-BAA-DM-DXXX-XXX 67A-AX-AAB-DM-DXXX-XXX 67A-AX-BAB-DM-DXXX-XXX DM-D XXX-XXX * Double Operator NO Valve NC Valve 10 1 10 1 1 1 67A-DX-AAA-DM-DXXX-XXX 67A-BX-AAA-DM-DXXX-XXX 67A-DX-BAA-DM-DXXX-XXX 67A-BX-BAA-DM-DXXX-XXX 67A-DX-AAB-DM-DXXX-XXX 67A-BX-AAB-DM-DXXX-XXX 67A-DX-BAB-DM-DXXX-XXX 67A-BX-BAB-DM-DXXX-XXX 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 (.9W) A 18 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) B 4 Locking recessed KD JC 4/60 (.9W) J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) DF 4 VDC (1.7W) BA * Other options available, see page 09. Spool type : OPTIONS 67A-XX-AAA-DM-DXXX-XXX Port configuration : G Single operator universal spool H Double operator universal spool 67A-XX-AXA-DM-DXXX-XXX Mounting style : A Standard pilot exhaust B Pilot exhaust to main exhaust* C Pilot exhaust out adapter* * Must use DU pilot. Replace DM with DU 67A-XX-XAA-DM-DXXX-XXX G O-Ring mount Spool return : 67A-XX-AAA-DM-DXXX-XXX Pilot style : 1 Standard return Standard return with memory spring (for use with single operator only) 67A-XX-AAA-DM-DXXX-XXX M Pilot exhaust muffled P Pilot exhaust piped (#10-) U Pilot exhaust to main exhaust Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 69 Consult Precautions page 7 before use, installation or service of MAC Valves..

ELECTRICAL WIXOM,MI.USA VAC TO 10 PSI WATTS MODIF. 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 67 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /4" : (14.5 C v ) 1" : (0.0 C v ) Class A continuous duty, # AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory ~ Inrush : 7.6 VA Holding : 4.8 VA = 1.7 to 1.0 W Energize : 9 ms De-energize : 1 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 117.9 51.7 4.0 1 10 1 197.9 APPROX. FOR SINGLE SOLENOID 6. APPROX. FOR DOUBLE SOLENOID OPTIONAL EXTERNAL PILOT 18.4 EP 1 10 17.6 4.0 59.0 18.7 9.0 84.8 10.5 9.0 MODEL AUCKLAND,N.Z. LIEGE,BELGIUM 71.9 70 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 69 Individual mounting Series Inline Manual operator Solenoid 4-way pilot with balanced poppet Air return 4 6 7 8 5 67 69 44 46 4 47 48P SERIES FEATURES High force MACSOLENOID. Optional low watt DC solenoids. Internal or external pilot. Normally open or normally closed function. Checked accumulator. May be plugged for -way operation. Bonded spool 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 71 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 69 Function Port size Flow (Max) Individual mounting Series / NO-NC, / NO-NC 1 1/ - - 1/ 60.0 C v Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways.. Balanced spool, immune to variations of pressure, also provides high flow.. Short stroke with high flow. 4. Bonded spool with minimum friction, shifting in a glass-like finished bore. 5. Pilot with balanced poppet, high flow, short and consistent response times. 6. Wiping effect eliminates sticking and contamination. HOW TO ORDER Port size 1 1/" Pilot air Single Operator NC valve 10 1 1 69A-A1-AAA-JXXX-XXX Single Operator NO valve 10 1 1 69A-C1-AAA-JXXX-XXX 4 6 7 8 5 67 69 44 46 " 1/" 1 1/" " 1/" Internal External 69A-A1-BAA-JXXX-XXX 69A-A1-CAA-JXXX-XXX 69A-A1-AAB-JXXX-XXX 69A-A1-BAB-JXXX-XXX 69A-A1-CAB-JXXX-XXX 69A-C1-BAA-JXXX-XXX 69A-C1-CAA-JXXX-XXX 69A-C1-AAB-JXXX-XXX 69A-C1-BAB-JXXX-XXX 69A-C1-CAB-JXXX-XXX 4 47 48P SOLENOID OPERATOR J XXX-XXX * (-G) Add G for ground 48 XX Voltage X Lead wire length X Manual operator XX AA 10 VAC (5,4W) 0 No lead wire 1 Non-locking BA DA 4 VDC (5,4W) A 18 Locking GA DB 1 VDC (5,4W) B 4 GG DC 4 VDC (,4W) C 6 DD 1 VDC (,4W) JB JD KA * Other options available, see page 17. Note : use 0 No lead wire for J, K and L type electrical connectors. KD AC voltage requires connector with rectifier. OPTIONS Pilot exhaust configuration: 69A-xx-xx X-JXXX-XXX A Standard pilot exhaust B Pilot exhaust out main exhaust Electrical connection* Flying leads MAC JAC Solenoid Plug-in MAC JAC Solenoid Plug-in with rectifier Rectangular connector Rectangular connector with light Mini square connector Mini square connector with light 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO M Manifold O Ring Mount 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 69 TECHNICAL DATA Fluid : Pressure range : Pilot Pressure: Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) Cv 60.0 Class A wire, # AWG x 18, continuous duty -15% to +10% of nominal voltage 5.4W.4W 1.8W Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 50.5 101.0 119.8 1/8" PILOT EXHAUST 161. 151.8 1/" PORTS SHOWN Ø 1.0 45.8 19.5 8.8.8 50.5 1 1 19.1 7.6 19.1 15.6 81. 1 EP 10 10 181.5 59.8 11.8 19.1 81.1 177.1 80.1 178.1 74 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 44 Individual mounting Series Inline 4 6 Manual operator Armature Coil 7 8 5 67 69 44 Push Pin EA 46 4 D seal B A IN 4 Balanced poppets 47 48P 48 Valve spring EB 400 9 SERIES FEATURES High force MACSOLENOID. 10mm direct operated. # 10- or M5 ports. Rated for lubricated or non-lubricated service. 9 ISO 01 ISO 0 ISO 1 ISO ISO 75 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 44 Function Port size Flow (Max) Individual Mounting Series 5/ M5, # 10-0.1 C v Inline OPERATIONAL BENEFITS 1. 10 mm valve, direct solenoid operated.. Balanced poppet, immune to variations of pressure.. Short stroke with high flow. 4. The patented solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER SOLENOID OPERATOR Port size Universal valve For use with external flow controls 4 6 7 8 5 67 69 44 B A B A 46 EB IN EA EB IN EA M5 # 10-44C-ABA-G XXX-XXX 44C-AAA-G XXX-XXX 44C-BBA-G XXX-XXX 44C-BAA-G XXX-XXX 4 LATCHING SOLENOID Port size Universal valve For use with external flow controls 47 48P M5 # 10- SOLENOID OPERATOR EB B A IN EA 44B-ABA-L XXX-XXX 44B-AAA-L XXX-XXX G XXX-XXX * XX Voltage X Wire length X Manual operator XX AA DC DD DF 10 VAC (.5W) 4 VDC (1.8W) 4 VDC (.5W) 4 VDC (4.0W) * Other options available, see page 11. Note : AC voltage requires connector with rectifier LATCHING SOLENOID A 18 B 4 L XXX-XXX * 1 Non-locking recessed Locking recessed EB B A IN EA 44B-BBA-L XXX-XXX 44B-BAA-L XXX-XXX BA BT GA KA KC KT Electrical connection Flying leads Flying leads with light MAC JAC Solenoid Plug-in Plug-in wire assembly. Plug-in wire assembly with rectifier & light Plug-in wire assembly with light 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX DF HA 4 VDC (4.0W) 4 VDC (1.95W) * Other options available, see page 19. A 18 B 4 C 6 0 No operator BA BJ KA KE LA Electrical connection Wire flying leads 4 Wire flying leads Wire plug-in assembly 4 Wire plug-in assembly Wire plug-in assembly (Polarity switching cover) 77 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 44 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 4 W : (0.10 C v ).5 W : (0.08 C v ) 1.8 W : (0.06 C v ) 1.0W : (0.05 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 4 W.5 W 1.8 W 1.0 W Energize :.4 ms De-energize : 1.5 ms Note : Valve and coil are not interchangeable. DIMENSIONS Dimensions shown are metric (mm) Ø. MTG. HOLES 1,5 C L C L A B EB IN EA 5,0 15,0 C L,5 59,9 0,0 10,0 9,7 1,0 0,0 10,0 5,0 15,0 5,0 5,0 10,0 5,7 78 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Individual mounting Series Inline Oval shaped armature Encapsulated coil Push pin Bonded balanced poppet Return spring Manifold mounting Stacking Manifold base plug-in Exh. In Manifold base plug-in with pressure regulators Manifold base plug-in with flow controls SERIES FEATURES Manifold base plug-in with PR & FC Patented high force MACSOLENOID for fastest possible response times. Bonded balanced poppet for high flow, precise repeatability, and consistent operation. Balanced poppet permits versatility in function may be used as -way or -way normally open or normally closed and may be used for vacuum, divertor, or selector applications. Extremely high cycle rate capability. Use on lube or non-lube service. Manual overrides as standard. Various solenoid enclosures and plug-in connectors. Optional surge suppression available. Low wattage DC solenoids down to 1. watts. Rectified AC voltage. A B 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 79 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Individual mounting Series 4/ 1/8 - # 10-0. C v Inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # 10- SOLENOID OPERATOR Without flow controls A EXH A B IN 46A-AA1-J XXX-XXX 46A-AB1-J XXX-XXX B Single Operator With flow controls A EXH A B IN 46A-AA-J XXX-XXX 46A-AB-J XXX-XXX B Without flow controls A J XXX-XXX * (-G) Add G for ground EXH A B IN 46A-GA1-J XXX-XXX 46A-GB1-J XXX-XXX B Double Operator With flow controls A EXH A B IN 46A-GA-J XXX-XXX 46A-GB-J XXX-XXX B 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX Single & double solenoid ** O No leads 1 Non-locking recessed BA AA 10 VAC (5.4W) A 18 Locking recessed GA DA 4 VDC (5.4W) B 4 GG DB 1 VDC (5.4W) C 6 Single solenoid only JB DC 4 VDC (.4W) JD DD 1 VDC (.4W) KA * Other options available, see page 17. KD ** Use with rectangular and mini connectors Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. Double solenoid requires minimum 5.4 watts. Examples : OPTIONS 46A-AA1-JXXX-XXX G Use with O ring mount (body option D & H ) A Single operator - 4 port body with side ports C Single operator - 4 port body with bottom ports (No side ports M5 or #10- ONLY) D Single operator - Bottom O ring mount All ports (No side ports) F Single operator - Bottom O ring mount Cylinder ports only Side inlet & exhaust G Double operator - 4 Port body - With side ports H Double operator - Bottom O ring mount - All ports (No side ports) 46A-DG1-Jxxx-xxx (Bottom O ring mount all ports) 46A-CB1-Jxxx-xxx (4 port body with bottom ports no side ports) Electrical connection Flying leads MAC JAC solenoid plug-in MAC JAC solenoid plug-in with rectifier Rectangular connector Rectangular connector with light Mini square connector Mini square connector with light 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 81 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C), mm 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage Consult factory 5.4W.4W 1.8W Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) Single solenoid Double solenoid 6.5 w/flow CONTROLS 4. 7.5.5 w/o FLOW CONTROLS.8 5.8 4..7 70.9 EX 8.5 11.0 18.8 EX 8.0 10.9 8.0 15. 15.7 15. 15.7 11.8 7.5.0.8 5.8 1/8" PORTS.5 16.. DIA. IN.5 11.4 8.0 109.4.0 Ø.4 () IN 8.0 6.5 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Manifold Mounting Series 4/ 1/8 - # 10-0. C v Stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # 10- SOLENOID OPERATOR Without flow controls A EXH A B IN 46A-SA1-J XXX-XXX 46A-SB1-J XXX-XXX B With flow controls A EXH A B IN 46A-SA-J XXX-XXX 46A-SB-J XXX-XXX J XXX-XXX * (-G) Add G for ground XX Voltage X Wire length X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) A 18 B 4 C 6 1 Non-locking recessed Locking recessed * Other options available, see page 17. Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. End plate kit required (port size 1/4") : M-46001-01. BA GA GB GG B Electrical connection Flying leads MAC JAC solenoid plug-in MAC JAC solenoid plug-in with diode MAC JAC solenoid plug-in with rectifier 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

- 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage Consult factory 5.4W.4W 1.8W Energize : 7.0 ms De-energize : 4.0ms Options : Spare parts : BSPP threads Inlet isolator : 8494 Exhaust isolator : 849 Tie rod (x) : 79411 DIMENSIONS WITH FLOW CONTROLS WITHOUT FLOW CONTROLS Dimensions shown are metric (mm) 5.0 15.0.6 Ø 5. Ø 5. 1.1 4.9 15.0 71.5 7.4 1.7 19.8 10.5 7.0 44.1 16.5 15.0 16.0 1/8" CYLINDER PORTS 10.1 1/4" INLET AND EXHAUST COMMONS.6 84 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Manifold mounting Series 4/ 1/8" - 5/ O.D. Pressed-in 0. C v tube receptacles Manifold base plug-in OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/ O.D. Pressed-in tube receptacles SOLENOID OPERATOR Single solenoid Double solenoid A B A B A B A B EXH IN EXH IN 46A-L00-00-J XXP-XXX 46A-N00-00-J XXP-XXX 46A-LSA-AC-J XXP-XXX 46A-NSA-BL-J XXP-XXX 46A-LSF-AC-J XXP-XXX 46A-NSF-BL-J XXP-XXX J XX P-XXX * (-G) Add G for ground 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX Single & double solenoid 1 Non-locking FA AA 10 VAC (5,4W) Locking FB AC 4 VAC (5,4W) FG DA 4 VDC (5,4W) DB 1 VDC (5,4W) Single solenoid only DC 4 VDC (,4W) DD 1 VDC (,4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. Double solenoid requires minimum 5.4 watts. OPTIONS 46A-LSB-AC-JXXP-XXX C Single solenoid - Side cylinder ports L Single & double solenoid - Bottom cylinder ports 0 Base only - no valve L Single solenoid - Base mount body M Single solenoid - Base mount body with gage port N Double solenoid - Base mount body P Double solenoid - Base mount body with gage port Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Example : base only : 46A-0SA-AC. End plate kit required (port size 1/4") : M-4600-01. 85 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orific e Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C). mm 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Epoxy encapsulated Class A wires 100% ED -15% to +10% of nominal voltage IP54 (electrical connection) 5.4W.4W 1.8W Energize : 7.0 ms De-energize : 4.0ms Options : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 DIMENSIONS Dimensions shown are metric (mm) 5.5 8.5 104.1 Double solenoid 5.5 8.5 104.1 18.6 16.5 8.0 8.0 4.0 78.0 95.5 6.9 15.0 95.5 6.9 15.0.8.5 4.4 94. Ø 4. 1/4" COMMONS.8.5 9.5 4.4 Ø 4. 9.5 4.0 5.5 19.0 4. 4.0 5.5 19.0 4. 79.0 79.0 95.5 95.5 /4"-14 NPSM 78.0 86 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Manifold mounting Series 4/ 1/8" - 5/ O.D. Pressed-in 0. C v tube receptacles OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERATOR Port size (Bottom ports only) Valve less base 1/8 NPTF 5/ O.D. Pressed-in tube receptacles Manifold base plug-in with pressure regulators Model number A EXH A B IN 46A-L00-00-J XXP-XXX 46A-LSA-AJ-J XXP-XXX 46A-LSF-AJ-J XXP-XXX J XX P-XXX * (-G) Add G for ground B 4 6 7 8 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX AA 10 VAC (5.4W) 1 Non-locking recessed FA DA 4 VDC (5.4W) Locking recessed FB DB 1 VDC (5.4W) FG DC 4 VDC (.4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. OPTIONS 46A-LSA-AJ-JXXP-XXX J Regulator with adjusting knob E Regulator with slotted stem G Regulator with slotted stem with locknut 0 Base only no valve L Base mount body M Base mount body with gage port Example : base only with regulator : 46A-0SA-AJ. End plate kit required (port size 1/4") : M-4600-01. Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 87 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult factory 5.4W.4W 1.8W Energize : 7.0 ms De-energize : 4.0ms Options : Spare parts : Regulating range options : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 Replacement regulators : PR46A-0AAA (slotted stem) PR46A-0BAA (adjusting knob) PR46A-0CAA (slotted stem with locknut) PR46A-xxxA A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI DIMENSIONS 18.6 16.5 Dimensions shown are metric (mm) 78.0 4.4 94..8.5 9.5 1/8" GAGE PORT 69. Ø 4. 1/4" COMMONS 5.5 8.5 104.1 4.0 19.0 4. 5.5 79.0 95.5 95.5 15.0 6.9 /4"-14 NPSM 88 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Manifold mounting Series 4/ 1/8" - 5/ O.D. Pressed-in 0. C v tube receptacles Manifold base plug-in with flow controls OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERATOR Port size Valve less base 1/8 NPTF 5/ O.D. Pressed-in tube receptacles XX Voltage X Manual operator XX AA 10 VAC (5.4W) 1 Non-locking recessed FA DA 4 VDC (5.4W) Locking recessed FB DB 1 VDC (5.4W) FG DC 4 VDC (.4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. OPTIONS 46A-LSA-AD-JXXP-XXX D Side cylinder ports M Bottom cylinder ports 0 Base only no valve L Base mount body M Base mount body with gage port Example : base only with flow controls: 46A-0SA-AD. End plate kit required (port size 1/4") : M-4600-01. Model number A EXH A B IN 46A-L00-00-J XXP-XXX 46A-LSA-AD-J XXP-XXX 46A-LSF-AD-J XXP-XXX J XX P-XXX * (-G) Add G for ground B Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 89 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult factory 5.4W.4W 1.8W Energize : 7.0 ms De-energize : 4.0ms Options : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 DIMENSIONS 18.6 16.5 8.0 Dimensions shown are metric (mm) 8.0 4.0 78.0 Ø 4..8 4.4 94. 1/4" COMMONS.5 9.5 104.1 5.5 4.0 19.0 8.5 5.5 4. 79.0 95.5 95.5 15.0 6.9 /4"-14 NPSM 90 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 46 Function Port size Flow (Max) Manifold mounting Series 4/ 1/8" - 5/ O.D. Pressed-in 0. C v tube receptacles Manifold base plug-in with PR & FC OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces.. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER SOLENOID OPERATOR Port size (Bottom ports only) Valve less base 1/8 NPTF 5/ O.D. Pressed-in tube receptacles XX Voltage X Manual operator XX AA 10 VAC (5.4W) 1 Non-locking recessed FA DA 4 VDC (5.4W) Locking recessed FB DB 1 VDC (5.4W) FG DC 4 VDC (.4W) * Other options available, see page 17. Note : AC voltage requires connector with rectifier. OPTIONS 46A-LSA-AK-JXXP-XXX K Regulator with adjusting knob & flow controls F Regulator with slotted stem & flow controls H Regulator with slotted stem with locknut & flow controls 0 Base only no valve L Base mount body M Base mount body with gage port Example : base only with regulator : 46A-0SA-AK. End plate kit required (port size 1/4") : M-4600-01. Model number A EXH A B IN 46A-L00-00-J XXP-XXX 46A-LSA-AK-J XXP-XXX 46A-LSF-AK-J XXP-XXX J XX P-XXX * (-G) Add G for ground B Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 91 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 46 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult factory 5.4W.4W 1.8W Energize : 7.0 ms De-energize : 4.0ms Options : Spare parts : Regulating range options : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 7944 Replacement regulators : PR46A-0AAA (slotted stem) PR46A-0BAA (adjusting knob) PR46A-0CAA (slotted stem with locknut) PR46A-xxxA A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI DIMENSIONS 18.6 16.5 Dimensions shown are metric (mm) 78.0.8 4.4 94..5 9.5 1/8" GAGE PORT 69. Ø 4. 1/4" COMMONS 5.5 8.5 104.1 4.0 19.0 4. 5.5 79.0 95.5 95.5 15.0 6.9 /4"-14 NPSM 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Manual operator Solenoid Individual mounting Sub-base non plug-in Sub-base plug-in Manifold mounting Manifold base non plug-in Manifold base plug-in Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Integral 4-way pilot 1 4 5 Series 4 6 7 8 5 67 69 44 46 4 47 48P 48 SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. Single or dual pressure. Internal or external pilot. Single or double solenoid. or position. Rectified AC voltage. Latching solenoid technology. Bonded spool Air return 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Individual mounting Series 5/, 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle Sub-base non plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (VALVE WITH BASE CODED FOR SIDE PORTS) Port size Valve less Pilot air Internal 5/ Single solenoid 4 1 14 15 4B-AMA-000-GXXX-XXX 5/ Double solenoid 4 1 14 15 4B-BMA-000-GXXX-XXX 5/ Closed center 1 4 14 15 4B-EMA-000-GXXX-XXX 5/ Open center 1 4 14 15 4B-FMA-000-GXXX-XXX 7 8 5 67 69 44 46 base # 10- External Internal 4B-AMD-000-GXXX-XXX 4B-AMA-AAL-GXXX-XXX 4B-BMD-000-GXXX-XXX 4B-BMA-AAL-GXXX-XXX 4B-EMD-000-GXXX-XXX 4B-EMA-AAL-GXXX-XXX 4B-FMD-000-GXXX-XXX 4B-FMA-AAL-GXXX-XXX 4 1/4 O.D. tube receptacles External Internal External 4B-AMD-AAM-GXXX-XXX 4B-AMA-EAL-GXXX-XXX 4B-AMD-EAM-GXXX-XXX 4B-BMD-AAM-GXXX-XXX 4B-BMA-EAL-GXXX-XXX 4B-BMD-EAM-GXXX-XXX 4B-EMD-AAM-GXXX-XXX 4B-EMA-EAL-GXXX-XXX 4B-EMD-EAM-GXXX-XXX 4B-FMD-AAM-GXXX-XXX 4B-FMA-EAL-GXXX-XXX 4B-FMD-EAM-GXXX-XXX 47 48P DUAL PRESSURE MODELS (VALVE WITH BASE CODED FOR SIDE PORTS) Port size Valve less base # 10-1/4 O.D. tube receptacles Internal External Internal External Internal External Pilot air STANDARD SOLENOID OPERATOR Supply # port Supply #5 port Supply # port Supply #5 port Supply # port Supply #5 port 5/ Single solenoid 4B-CMB-000-GXXX-XXX 4B-CMC-000-GXXX-XXX 4B-CMD-000-GXXX-XXX 4B-CMB-AAL-GXXX-XXX 4B-CMC-AAL-GXXX-XXX 4B-CMD-AAM-GXXX-XXX 4B-CMB-EAL-GXXX-XXX 4B-CMC-EAL-GXXX-XXX 4B-CMD-EAM-GXXX-XXX G XXX-XXX * 5/ Double solenoid 4B-DMB-000-GXXX-XXX 4B-DMC-000-GXXX-XXX 4B-DMD-000-GXXX-XXX 4B-DMB-AAL-GXXX-XXX 4B-DMC-AAL-GXXX-XXX 4B-DMD-AAM-GXXX-XXX 4B-DMB-EAL-GXXX-XXX 4B-DMC-EAL-GXXX-XXX 4B-DMD-EAM-GXXX-XXX XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DC 4 VDC (1.8W) B 4 Locking recessed BT DD 4 VDC (.5W) C 6 GA DF 4 VDC (4.0W) KA KT Note : AC voltage requires connector with rectifier. * Other options available, see page 11. KD Latching solenoid available for 5/ valves. Other options available for the 4 series valves, see page 107. 14 5 4 1 1 14 5 4 1 1 5/ Pressure center 1 4 14 15 4B-HMB-000-GXXX-XXX 4B-HMC-000-GXXX-XXX 4B-HMD-000-GXXX-XXX 4B-HMB-AAL-GXXX-XXX 4B-HMC-AAL-GXXX-XXX 4B-HMD-AAM-GXXX-XXX 4B-HMB-EAL-GXXX-XXX 4B-HMC-EAL-GXXX-XXX 4B-HMD-EAM-GXXX-XXX Electrical connection Flying leads Flying leads with light MAC JAC solenoid Plug-in Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 95 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot - pos. : 0 to 10 PSI pos. : 40 to 10 PSI External Pilot : vacuum to 10 PSI position : 0 to 10 PSI position : 40 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-BB Sandwich regulator : see Regulator section DIMENSIONS Dimensions shown are metric (mm) (SHOWN WITH M7 PORTS).7 18.5 9.5 1.1 DOUBLE 4. 4.8 76.5 5.5.4 4 4.8 1 5.0 5 1 99.1 MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. Ø 5. 96 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Individual mounting Series 5/, 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle Sub-base plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) - MODELS CODED FOR SIDE PORTS Port size Valve less base # 10-1/4 O.D. tube receptacles Port size Valve less base # 10-1/4 O.D. tube receptacles Pilot air Internal External Internal External Internal External Internal External Internal External Internal External 5/ Single solenoid 4 1 14 15 4B-AMA-000-GXXP-XXX 4B-AMD-000-GXXP-XXX 4B-AMA-AAA-GXXP-XXX 4B-AMD-AAB-GXXP-XXX 4B-AMA-EAA-GXXP-XXX 4B-AMD-EAB-GXXP-XXX Pilot air Supply # port Supply #5 port Supply # port Supply #5 port Supply # port Supply #5 port 5/ Double solenoid 4 1 14 15 4B-BME-000-GXXP-XST 4B-BMH-000-GXXP-XST 4B-BME-AAC-GXXP-XST 4B-BMH-AAD-GXXP-XST 4B-BME-EAC-GXXP-XST 4B-BMH-EAD-GXXP-XST 5/ Single solenoid 4B-CMB-000-GXXP-XXX 4B-CMC-000-GXXP-XXX 4B-CMD-000-GXXP-XXX 4B-CMB-AAA-GXXP-XXX 4B-CMC-AAA-GXXP-XXX 4B-CMD-AAB-GXXP-XXX 4B-CMB-EAA-GXXP-XXX 4B-CMC-EAA-GXXP-XXX 4B-CMD-EAB-GXXP-XXX 5/ Closed center 1 4 14 15 4B-EME-000-GXXP-XST 4B-EMH-000-GXXP-XST 4B-EME-AAC-GXXP-XST 4B-EMH-AAD-GXXP-XST 4B-EME-EAC-GXXP-XST 4B-EMH-EAD-GXXP-XST DUAL PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) - MODELS CODED FOR SIDE PORTS STANDARD SOLENOID OPERATOR 14 5 4 1 G XX P-XXX * 1 5/ Double solenoid 14 5 4 1 4B-DMF-000-GXXP-XST 4B-DMG-000-GXXP-XST 4B-DMH-000-GXXP-XST 4B-DMF-AAC-GXXP-XST 4B-DMG-AAC-GXXP-XST 4B-DMH-AAD-GXXP-XST 4B-DMF-EAC-GXXP-XST 4B-DMG-EAC-GXXP-XST 4B-DMH-EAD-GXXP-XST 1 5/ Open center 1 4 14 15 4B-FME-000-GXXP-XST 4B-FMH-000-GXXP-XST 4B-FME-AAC-GXXP-XST 4B-FMH-AAD-GXXP-XST 4B-FME-EAC-GXXP-XST 4B-FMH-EAD-GXXP-XST 5/ Pressure center 1 4 14 15 4B-HMF-000-GXXP-XST 4B-HMG-000-GXXP-XST 4B-HMH-000-GXXP-XST 4B-HMF-AAC-GXXP-XST 4B-HMG-AAC-GXXP-XST 4B-HMH-AAD-GXXP-XST 4B-HMF-EAC-GXXP-XST 4B-HMG-EAC-GXXP-XST 4B-HMH-EAD-GXXP-XST 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Manual operator XX Electrical connection AA 10 VAC (.5W) 1 Non-locking recessed Double solenoid & position models DC 4 VDC (1.8W) Locking recessed ST Base plug-in DD 4 VDC (.5W) Single solenoid models DF 4 VDC (4.0W) SA Base plug-in SJ Base plug-in with light Note : AC voltage requires connector with rectifier (for double solenoid consult factory). SS Base plug-in with rectifier & light & ground * Other options available, see page 11. Other options available for the 4 series valves, see page 108. 97 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot - pos. : 0 to 10 PSI pos. : 40 to 10 PSI External Pilot : vacuum to 10 PSI position : 0 to 10 PSI position : 40 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-AB Sandwich regulator : see Regulator section DIMENSIONS 0.0 Dimensions shown are metric (mm) 6.0 (M7 PORTS SHOWN) 4.5 4 75.0 1/4" IN&EXH COMMONS 6.0.0 16.9 11.1 9.5 66.5 6.0 7.6 0.5. 4.0. 40.1 5 94.4 67.5 56.5 1 75. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. EP Ø 4. 1/8" COMMON EXT. PILOT COND 1"-11 1/ NPSM 11.0 46.0 98 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle Manifold base non plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (MIDDLE STATION MANIFOLDS WITH SIDE PORTS) Port size Valve less Pilot air Internal 5/ Single solenoid 4 1 14 15 4B-AMA-000-GXXX-XXX 5/ Double solenoid 4 1 14 15 4B-BMA-000-GXXX-XXX 5/ Closed center 1 4 14 15 4B-EMA-000-GXXX-XXX 5/ Open center 1 4 14 15 4B-FMA-000-GXXX-XXX 7 8 5 67 69 44 46 base # 10- External Internal 4B-AMD-000-GXXX-XXX 4B-AMA-AJL-GXXX-XXX 4B-BMD-000-GXXX-XXX 4B-BMA-AJL-GXXX-XXX 4B-EMD-000-GXXX-XXX 4B-EMA-AJL-GXXX-XXX 4B-FMD-000-GXXX-XXX 4B-FMA-AJL-GXXX-XXX 4 1/4 O.D. tube receptacles External Internal External 4B-AMD-AJM-GXXX-XXX 4B-AMA-EJL-GXXX-XXX 4B-AMD-EJM-GXXX-XXX 4B-BMD-AJM-GXXX-XXX 4B-BMA-EJL-GXXX-XXX 4B-BMD-EJM-GXXX-XXX 4B-EMD-AJM-GXXX-XXX 4B-EMA-EJL-GXXX-XXX 4B-EMD-EJM-GXXX-XXX 4B-FMD-AJM-GXXX-XXX 4B-FMA-EJL-GXXX-XXX 4B-FMD-EJM-GXXX-XXX 47 48P DUAL PRESSURE MODELS (MIDDLE STATION MANIFOLDS WITH SIDE PORTS) Port size Pilot air 5/ Single solenoid 5/ Double solenoid 5/ Pressure center 48 14 4 1 14 4 1 1 4 14 Valve less base Internal External Supply # port Supply #5 port 4B-CMB-000-GXXX-XXX 4B-CMC-000-GXXX-XXX 4B-CMD-000-GXXX-XXX 5 1 5 4B-DMB-000-GXXX-XXX 4B-DMC-000-GXXX-XXX 4B-DMD-000-GXXX-XXX 1 15 4B-HMB-000-GXXX-XXX 4B-HMC-000-GXXX-XXX 4B-HMD-000-GXXX-XXX 400 9 # 10- Internal Supply # port Supply #5 port 4B-CMB-AJL-GXXX-XXX 4B-CMC-AJL-GXXX-XXX 4B-DMB-AJL-GXXX-XXX 4B-DMC-AJL-GXXX-XXX 4B-HMB-AJL-GXXX-XXX 4B-HMC-AJL-GXXX-XXX 9 1/4 O.D. tube receptacles External Internal External STANDARD SOLENOID OPERATOR Supply # port Supply #5 port 4B-CMD-AJM-GXXX-XXX 4B-CMB-EJL-GXXX-XXX 4B-CMC-EJL-GXXX-XXX 4B-CMD-EJM-GXXX-XXX G XXX-XXX * 4B-DMD-AJM-GXXX-XXX 4B-DMB-EJL-GXXX-XXX 4B-DMC-EJL-GXXX-XXX 4B-DMD-EJM-GXXX-XXX 4B-HMD-AJM-GXXX-XXX 4B-HMB-EJL-GXXX-XXX 4B-HMC-EJL-GXXX-XXX 4B-HMD-EJM-GXXX-XXX ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX Electrical connection AA 10 VAC (.5W) A 18 1 Non-locking recessed BA Flying leads DC 4 VDC (1.8W) B 4 Locking recessed BT Flying leads with light DD 4 VDC (.5W) C 6 GA MAC JAC solenoid plug-in DF 4 VDC (4.0W) KA Plug-in wire assy. KT Plug-in wire assy. with light Note : - AC voltage requires connector with rectifier. * Other options available, see page 11. KD Plug-in wire assy. with Latching solenoid available for 5/ valves. rectifier & light & ground Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 4 series valves, see page 107. 99 Consult Precautions page 7 before use, installation or service of MAC Valves..

5 1 1 5 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot - pos. : 0 to 10 PSI pos. : 40 to 10 PSI External Pilot : vacuum to 10 PSI position : 0 to 10 PSI position : 40 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-BB Sandwich regulator : see "regulators" section Isolator disk for inlet or exhaust: 8454 Valve blanking plate : M-4004 DIMENSIONS Dimensions shown are metric (mm) (SHOWN WITH M7 PORTS) 76.5 10.5 1.8 18.5 5.5.4.8 4 4 4 95.1 WITH OPTIONAL SANDWICH FLOW CONTROL 4MM HEX WRECH REQUIRED FOR INTALLATION OF 1/4" AND 6MM TUBE RECEPTACLES OPTIONAL SCREW IN TUBE RECEPTACLE 0.4 *SIDE AND BOTTOM PORTS ARE AVAILABLE IN 10-, M5, M7, AND SCREW IN 1/4" AND 6MM TUBE RECEPTACLES 17.0 17.0 10. 99.1 4.8 5.6 4. 1 1 1 MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. Ø 5. 16.9 11.1 9.5. 40. 56.7 70.4.1 45.0 58.0 18.5 10.5 4 4 4 1/4" IN & EXH COMMONS 1/8" EXT. PILOT COMMON 100 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle Manifold base plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) Port size Valve less Pilot air Internal 5/ Single solenoid 4 1 14 15 4B-AMA-000-GXXP-XXX 5/ Double solenoid 4 1 14 15 4B-BME-000-GXXP-XST 5/ Closed center 1 4 14 15 4B-EME-000-GXXP-XST 5/ Open center 1 4 14 15 4B-FME-000-GXXP-XST 7 8 5 67 69 44 46 base # 10- External Internal 4B-AMD-000-GXXP-XXX 4B-AMA-AJA-GXXP-XXX 4B-BMH-000-GXXP-XST 4B-BME-AJC-GXXP-XST 4B-EMH-000-GXXP-XST 4B-EME-AJC-GXXP-XST 4B-FMH-000-GXXP-XST 4B-FME-AJC-GXXP-XST 4 1/4 O.D. tube receptacles External Internal External 4B-AMD-AJB-GXXP-XXX 4B-AMA-EJA-GXXP-XXX 4B-AMD-EJB-GXXP-XXX 4B-BMH-AJD-GXXP-XST 4B-BME-EJC-GXXP-XST 4B-BMH-EJD-GXXP-XST 4B-EMH-AJD-GXXP-XST 4B-EME-EJC-GXXP-XST 4B-EMH-EJD-GXXP-XST 4B-FMH-AJD-GXXP-XST 4B-FME-EJC-GXXP-XST 4B-FMH-EJD-GXXP-XST 47 48P DUAL PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) Port size Valve less base # 10-1/4 O.D. tube receptacles Internal External Internal External Internal External Pilot air STANDARD SOLENOID OPERATOR Supply # port Supply #5 port Supply # port Supply #5 port Supply # port Supply #5 port 5/ Single solenoid 14 5 4 1 4B-CMB-000-GXXP-XXX 4B-CMC-000-GXXP-XXX 4B-CMD-000-GXXP-XXX 4B-CMB-AJA-GXXP-XXX 4B-CMC-AJA-GXXP-XXX 4B-CMD-AJB-GXXP-XXX 4B-CMB-EJA-GXXP-XXX 4B-CMC-EJA-GXXP-XXX 4B-CMD-EJB-GXXP-XXX G XX P-XXX * 1 5/ Double solenoid 14 4B-DMF-000-GXXP-XST 4B-DMG-000-GXXP-XST 4B-DMH-000-GXXP-XST 4B-DMF-AJC-GXXP-XST 4B-DMG-AJC-GXXP-XST 4B-DMH-AJD-GXXP-XST 4B-DMF-EJC-GXXP-XST 4B-DMG-EJC-GXXP-XST 4B-DMH-EJD-GXXP-XST 5 4 1 1 5/ Pressure center 1 4 14 15 4B-HMF-000-GXXP-XST 4B-HMG-000-GXXP-XST 4B-HMH-000-GXXP-XST 4B-HMF-AJC-GXXP-XST 4B-HMG-AJC-GXXP-XST 4B-HMH-AJD-GXXP-XST 4B-HMF-EJC-GXXP-XST 4B-HMG-EJC-GXXP-XST 4B-HMH-EJD-GXXP-XST Above numbers are middle station manifolds with side ports 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Manual operator XX Electrical connection AA 10 VAC (.5W) 1 Non-locking recessed Double solenoid & position models DC 4 VDC (1.8W) Locking recessed ST Base plug-in DD 4 VDC (.5W) Single solenoid models DF 4 VDC (4.0W) SA Base plug-in SJ Base plug-in with light * Other options available, see page 11. ** Latching solenoid available for 5/ valves. SS Base plug-in with rectifier & light & ground Note : - AC voltage requires connector with rectifier (for double solenoid consult factory). - Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 4 series valves, see page 108. 101 Consult Precautions page 7 before use, installation or service of MAC Valves..

5 1 X 4 4 1 WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. 1 1 MODIF. WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. 1 MODEL MODEL MODEL MODEL X 1 5 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot - pos. : 0 to 10 PSI pos. : 40 to 10 PSI External Pilot : vacuum to 10 PSI position : 0 to 10 PSI position : 40 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-AB Sandwich regulator : see "regulators" section Isolator disk for inlet or exhaust: 8454 Valve blanking plate : M-4004 Plug-in wire protector : 4180 DIMENSIONS Dimensions shown are metric (mm).7 10.5 18.5 1.8 5.5 16.9 4MM HEX WRECH REQUIRED FOR INTALLATION OF 1/4" AND 6MM TUBE RECEPTACLES WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z..1 45.0 68.4 18.5 10.5 4 4 4 4 4 66.5 OPTIONAL SCREW IN TUBE RECEPTACLE 17.0 17.0 1/4" IN & EXH COMMONS 5.0 4. WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. Ø 5. 75.0..0 0.0 16.9 11.1 9.5. 40.4 56.7 68.5 94.0 114.0 4 1"-11 1/ CONDUIT 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Individual/Manifold mounting Series 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base # 10-1/4 O.D. tube receptacles Pilot air Internal External Internal External Internal External DUAL PRESSURE MODELS (INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base # 10-1/4 O.D. tube receptacles Internal External Internal External Internal External Pilot air Supply # port Supply #5 port Supply # port Supply #5 port Supply # port Supply #5 port LATCHING SOLENOID OPERATOR 5/ Single pressure 1 L XXX-XXX * 4 15 14 4A-AMA-000-LXXX-XXX 4A-AMD-000-LXXX-XXX 4A-AMA-AAL-LXXX-XXX 4A-AMD-AAM-LXXX-XXX 4A-AMA-EAL-LXXX-XXX 4A-AMD-EAM-LXXX-XXX Sub-base/ manifold base non plug-in with latching solenoid 5/ Dual pressure 1 4 15 14 4A-CMB-000-LXXX-XXX 4A-CMC-000-LXXX-XXX 4A-CMD-000-LXXX-XXX 4A-CMB-AAL-LXXX-XXX 4A-CMC-AAL-LXXX-XXX 4A-CMD-AAM-LXXX-XXX 4A-CMB-EAL-LXXX-XXX 4A-CMC-EAL-LXXX-XXX 4A-CMD-EAM-LXXX-XXX Photo: Middle station manifold base 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX DF 4 VDC (4.0 W) HA 4 VDC (1.95 W) A 18 B 4 C 6 0 No operator * Other options available, see page 19. Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 4 series valves, see page 107. BA KA LA KE Electrical connection Wire Flying leads Wire Plug-in Assembly wire plug-in assembly (polarity switching cover) 4-wire plug-in assembly 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

X p 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-BB Sandwich regulator : see "regulators" section Isolator disk for inlet or exhaust: 8454 Valve blanking plate : M-4004 DIMENSIONS Individual base 18.5 15. CL CL 10.5 C L Dimensions shown are metric (mm) Manifold base 7.6 6.0.5 4 4.1 6.0 76.5 95.1 WITH OPTIONAL SANDWICH FLOW CONTROL 4MM HEX WRENCH REQURIED FOR INSTALLATION OF 1/4" AND 6MM TUBE RECEPTACLES 4.0 5.0 6.0 Ø 4. 1 5 75.4 79.1 107.9 WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL EP.0 16.9 11.1 9.5 18.5 10.5. 40.1 56.5.9 45. 67.4 EP 79.1 107.9 74.7 MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. Ø 4. OPTIONAL SCREW IN TUBE RECEPTACLE 17.0 7. 17.0 8.0 4.0 6.0 58.0 67.4 5 4 1 49.9 1.7 4.7 1/4" IN & EXH COMMONS 1/8" EXT. PILOT COMMON 8.0 104 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 Function Port size Flow (Max) Individual/Manifold mounting Series 5/ # 10- - 0.4 C v 1/4 O.D. tube receptacle OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers).. High flow (up to 0.4 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (-WIRE INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base # 10-1/4 O.D. tube receptacles Pilot air Internal External Internal External Internal External DUAL PRESSURE MODELS (-WIRE INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base # 10-1/4 O.D. tube receptacles Internal External Internal External Internal External Pilot air Supply # port Supply #5 port Supply # port Supply #5 port Supply # port Supply #5 port LATCHING SOLENOID OPERATOR 5/ Single pressure 1 L XX P-XXX * 4 15 14 4A-AMA-000-LXXP-XXX 4A-AMD-000-LXXP-XXX 4A-AMA-AAA-LXXP-XXX 4A-AMD-AAB-LXXP-XXX 4A-AMA-EAA-LXXP-XXX 4A-AMD-EAB-LXXP-XXX Sub-base/ manifold base plug-in with latching solenoid 5/ Dual pressure 1 4 15 14 4A-CMB-000-LXXP-XXX 4A-CMC-000-LXXP-XXX 4A-CMD-000-LXXP-XXX 4A-CMB-AAA-LXXP-XXX 4A-CMC-AAA-LXXP-XXX 4A-CMD-AAB-LXXP-XXX 4A-CMB-EAA-LXXP-XXX 4A-CMC-EAA-LXXP-XXX 4A-CMD-EAB-LXXP-XXX 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Manual operator XX DF 4 VDC (4.0W) 0 No operator DA HA 4 VDC (1.95W) EA Electrical connection** Plug-in Plug-in pin (polarity switching cover) * Other options available, see page 19. ** For latching solenoid and 4 wire, use electrical connector DA, DB, DC or DD. For wire latching, use the "EA" connector. Other options available for the 4 series valves, see page 108. 105 Consult Precautions page 7 before use, installation or service of MAC Valves..

5 1 1 5 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 4 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4V 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) # 10- : (0.5 C v ) 1/4 O.D. tube receptacle : (0.4 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.95 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : M5 ports, M7 ports, 6 mm O.D. tube receptacles Sandwich flow controls : FC4B-AB Sandwich regulator : see "regulators" section Isolator disk for inlet or exhaust: 8454 Valve blanking plate : M-4004 Plug-in wire protector : 4180 DIMENSIONS 1/4" IN&EXH COMMONS 6.0.0 16.9 11.1 66.5 Individual base 6.0 Dimensions shown are metric (mm) Port A Dim. M4 Tube Fitting.70 4.5 6.0 71.5 0.0 10.5 Manifold base A. 9.5 4.0 M5 or 10- M7.0.40 4 4 40.1 56.5 67.5 94.4 1 5 EP 75. WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL. 6.0.0 16.9 11.1 9.5 66.5 4.0 6.0 Ø 4. 40.1 94.4 56.5 67.5 75. Ø 4. EP 1/8" COMMON EXT. PILOT COND 7.6 0.5 1"-11 1/ NPSM 11.0 COND 11.0 6.0 4.5 0.0 45..8 0.0 4 4 4 EP 114.0 COND MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. LIEGE, BELGIUM AUCKLAND, N.Z. 7.6 1/8" COMMON EXT. PILOT 0.5 1/4" IN&EXH COMMONS 46.0 1"-11 1/ NPSM C L C L C L C L 46.0 106 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 OPTIONS FOR NON PLUG-IN VALVES Base type : Individual base 4B-XXX-XAX-GXXX-XXX Universal spool 4B-RXX-XXX-GXXX-XXX Base only : 4B-000-XXX (i.e. 4B-000-AAL) Pilot style : 4B-XMX-XXX-GXXX-XXX A Individual base Side ports B Individual base Bottom ports R position single solenoid universal spool S position double solenoid universal spool M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust - Individual base Manifold base 4B-XXX-XJX-GXXX-XXX J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports 4B-000-XXX (i.e. 4B-000-AJL) - Manifold base 4 6 7 8 5 67 69 44 46 4 47 48P Base/Manifold configurations for LATCHING SOLENOID VALVES : 4A-XXX-XAX-LXXX-XXX A Individual base Side ports B Individual base Bottom ports J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 107 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 4 OPTIONS FOR PLUG-IN VALVES Base type : Individual base 4B-XXX-XAX-GXXP-XXX A Individual base Side ports B Individual base Bottom ports Manifold base 4B-XXX-XJX-GXXP-XXX J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports Universal spool 4B-RXX-XXX-GXXP-XXX R position single solenoid universal spool S position double solenoid universal spool Base only : 4B-000-XXX (i.e. 4B-000-AAC) - Individual base wired for a double solenoid 4B-000-XXX (i.e. 4B-000-AJA) - Manifold base wired for a single solenoid For LED with diode ( & position double solenoid valves) 4B-XXJ-XXX-GXXP-XST J Internal pilot single pressure K Internal pilot dual pressure supply from # port L Internal pilot dual pressure supply from #5 port M External pilot Pilot style : 4B-XMX-XXX-GXXP-XXX M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust Base/Manifold configurations for LATCHING SOLENOID VALVES : 4A-XXX-XAX-LXXP-XXX A Individual base Side ports B Individual base Bottom ports J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports Base/Manifold options for int./ext. pilot for LATCHING SOLENOID VALVES : 4A-XXX-XXA-LXXP-XXX A Plug-in Int. Pilot Wire Latching B Plug-in Ext. Pilot Wire Latching C Plug-in Int. Pilot Wire Latching D Plug-in Ext. Pilot Wire Latching E Plug-in Int. Pilot 4 Wire Latching F Plug-in Ext. Pilot 4 Wire Latching 108 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 47 Individual mounting Series Inline Sub-base non plug-in Manifold mounting Stacking Manifold base plug-in 4 6 Manual operator Armature Coil Push pin 7 8 5 67 69 44 46 Pole piece D seal Conical seat 4 5 1 4 47 48P Poppet 48 Valve return spring 400 9 SERIES FEATURES Short stroke solenoid produces high energization shifting force. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces. Built-in wear compensation - valve stroke is shorter than solenoid stroke. Four (4) bonded balanced poppets on a one-piece valve stem. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. Exhaust seals are not under inlet pressure thus reducing friction. Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. 9 ISO 01 ISO 0 ISO 1 ISO ISO 109 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow (Max) Individual Mounting Series 5/ 1/8-1/4 0.5 C v Inline OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force.. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces.. Built-in wear compensation valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a onepiece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing friction. HOW TO ORDER Port size 1/8 NPTF 1/4 NPTF SOLENOID OPERATOR 7. Integral non-rising flow controls available on inline models. 8. Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Without flow controls 1 4 1 5 14 47A-AA0-H XXX-XXX 47A-AB0-H XXX-XXX H XXX-XXX * XX Voltage X Lead Wire length X Manual operator XX DA DB DC DD AA 4 VDC (5.W) 4 VDC (.4W) 4 VDC (1.8W) 4 VDC (1.0W) 10 VAC (6.7W) * Other options available, see page 15. Note: AC voltage requires connector with rectifier. A 18 B 4 C 6 1 Non-locking recessed Locking recessed With flow controls 1 4 1 5 14 47A-BA0-H XXX-XXX 47A-BB0-H XXX-XXX MA MC BA BC MT Electrical connection Plug-in wire assembly Plug-in wire assembly with light Flying leads Flying leads with light Plug-in wire assembly with rectifier & light 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 LATCHING OPERATOR * Other options available, see page 19. L XXX-XXX * XX Voltage X Lead Wire length X Manual operator XX DA DF 4 VDC (5.W) 1 VDC (5.W) A 18 B 4 C 6 0 No operator BA BJ LA MA ME Electrical connection Wire Flying leads 4 Wire Flying leads Wire Plug-in (Polarity switching cover) Wire Plug-in 4 Wire Plug-in 9 ISO 01 ISO 0 ISO 1 ISO ISO OPTIONS Namur Mount Option (w/o flow controls) 47A-CXO-HXXX-XXX A 1/8 NPTF B 1/4 NPTF 111 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 47 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5. W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.W : (0.50 C v ).4W : (0.5 C v ) 1.0W : (0.0 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 5.W.4W 1.0W Energize : 17.4 ms De-energize :.8 ms Options : Spare parts : BSPP threads Flow control assembly : N-47004 DIMENSIONS Dimensions shown are metric (mm) 5.5 10.5 4.5 DIA. MTG. HOLES () 56.55 14 1 40.5 A 0. B 116.85 9.8 TYP () 9.0 TYP () 1 5 - + + - 9.75 4 9.5 9.75 19.5 OPTIONAL FLOW CONTROL COVER 1.75 41.5 Dim A B 1/8 50.6 11.95 1/4 49. 11. 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow (Max) Individual Mounting Series 5/ 1/8-1/4 0.5 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force.. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces.. Built-in wear compensation valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a onepiece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing friction. HOW TO ORDER Port size 7. Integral non-rising flow controls available on inline models. 8. Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Without flow controls 4 With flow controls 4 4 6 7 8 5 67 69 44 Valve less base 1 1 5 14 47A-L10-H XXX-XXX 1 14 1 5 47A-L10-H XXX-XXX 46 1/8 NPTF 1/4 NPTF 47A-LAA-H XXX-XXX 47A-LBA-H XXX-XXX 47A-LAB-H XXX-XXX 47A-LBB-H XXX-XXX 4 SOLENOID OPERATOR H XXX-XXX * 47 48P XX Voltage X Lead Wire length X Manual operator XX DA DB DC DD AA 4 VDC (5.W) 4 VDC (.4W) 4 VDC (1.8W) 4 VDC (1.0W) 10 VAC (6.7W) * Other options available, see page 15. Note: AC voltage requires connector with rectifier. LATCHING OPERATOR A 18 B 4 C 6 L XXX-XXX * 1 Non-locking recessed Locking recessed XX Voltage X Lead Wire length X Manual operator XX DA DF 4 VDC (5.W) 1 VDC (5.W) A 18 B 4 C 6 0 No operator MA MC BA BC MT BA BJ LA MA ME Electrical connection Plug-in wire assembly Plug-in wire assembly with light Flying leads Flying leads with light Plug-in wire assembly with rectifier & light Electrical connection Wire Flying leads 4 Wire Flying leads Wire Plug-in (Polarity switching cover) Wire Plug-in 4 Wire Plug-in 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO * Other options available, see page 19. 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 47 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5. W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.W : (0.50 C v ).4W : (0.5 C v ) 1.0W : (0.0 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 5.W.4W 1.0W Energize : 17.4 ms De-energize :.8 ms Options : Spare parts : BSPP threads Pressure seal body to base: 1668 Mounting screw (x): 504 Flow control assembly (x): N-04001 DIMENSIONS Dimensions shown are metric (mm) - + G 4.0 DIA. () HOLES E A H G F 5 1 67.0 14 14 11.0 5.10 4 B C 1 1 54.6 APPROX 8.10 5.0 D 7.1 APPROX 8.1 DIM. A B C D E F G H 1/8" 8.0.9 48.6 19.05 9.5 1.5 4. 59.0 1/4" 9.5 4.0 48.8.0 1.5 1.8 4. 57. 114 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow (Max) Manifold Mounting Series 5/ 1/8-1/4 0.5 C v Stacking OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force.. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces.. Built-in wear compensation valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a onepiece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing friction. HOW TO ORDER Port size 1/8 NPTF 1/4 NPTF SOLENOID OPERATOR 7. Integral non-rising flow controls available on inline models. 8. Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Without flow controls 1 4 1 5 14 47A-SA0-H XXX-XXX 47A-SB0-H XXX-XXX H XXX-XXX * XX Voltage X Lead Wire length X Manual operator XX DA DB DC DD AA 4 VDC (5.W) 4 VDC (.4W) 4 VDC (1.8W) 4 VDC (1.0W) 10 VAC (6.7W) * Other options available, see page 15. Note: AC voltage requires connector with rectifier. A 18 B 4 C 6 1 Non-locking recessed Locking recessed With flow controls 1 4 1 5 14 47A-TA0-H XXX-XXX 47A-TB0-H XXX-XXX MA MC BA BC MT Electrical connection Plug-in wire assembly Plug-in wire assembly with light Flying leads Flying leads with light Plug-in wire assembly with rectifier & light 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 LATCHING OPERATOR * Other options available, see page 19. End plate kit required: M-4701-01 (1/4 NPTF). L XXX-XXX * XX Voltage X Lead Wire length X Manual operator XX DA DF 4 VDC (5.W) 1 VDC (5.W) A 18 B 4 C 6 0 No operator BA BJ LA MA ME Electrical connection Wire Flying leads 4 Wire Flying leads Wire Plug-in (Polarity switching cover) Wire Plug-in 4 Wire Plug-in 9 ISO 01 ISO 0 ISO 1 ISO ISO 115 Consult Precautions page 7 before use, installation or service of MAC Valves..

5. Ø 6. THRU. 46.0 15.8 95.0 14.8 0. 1 4 1 4 1 4 1 18.9 14 14 14 117.1 AUCKLAND,N.Z. LIEGE,BELGIUM MODEL ELECTRICAL WATTS WIXOM,MI.,USA MODIF. 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 47 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 5. W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.W : (0.50 C v ).4W : (0.5 C v ) 1.0W : (0.0 C v ) Class A wires (# AWG x 18), continuous duty -15% to +10% of nominal voltage 5.W.4W 1.0W Energize : 17.4 ms De-energize :.8 ms Options : Spare parts : BSPP threads Inlet isolator: 8451 Exhaust isolator: N-47009 Tie Rod (x): 79057 DIMENSIONS Dimensions shown are metric (mm) 19.0 A 1 B 59.5 Ø 6. THRU. 0.7 Dim A B 5. 1/8 1/4.8 4. 18.4 19 116 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 47 Function Port size Flow (Max) Manifold Mounting Series 5/ 1/8-1/4 0.5 C v Manifold base plug-in OPERATIONAL BENEFITS 1. Short stroke solenoid produces high energization shifting force.. High force return spring due to high force solenoid maximizes both energization and de-energization shifting forces.. Built-in wear compensation valve stroke is shorter than solenoid stroke. 4. Four bonded balanced poppets on a onepiece valve stem. 5. End poppets seal first on conical seats and cushion inlet poppet, eliminating cutting. 6. Exhaust seals are not under inlet pressure thus reducing friction. HOW TO ORDER Port size 7. Integral non-rising flow controls available on inline models. 8. Short stroking balanced poppet allows for direct solenoid operation with high shifting forces, minimized friction, fast response and high flow in a small package. Model number 4 Photo: Middle station manifold base 4 6 7 8 5 67 69 44 Valve less base 1 14 1 5 47A-L10-H XXP-XXX 46 1/8 NPTF 1/4 NPTF 47A-LAJ-H XXP-XXX 47A-LBJ-H XXP-XXX 4 SOLENOID OPERATOR H XX P-XXX * 47 48P XX Voltage X Manual operator XX DA DB DC DD AA 4 VDC (5.W) 4 VDC (.4W) 4 VDC (1.8W) 4 VDC (1.0W) 10 VAC (6.7W) * Other options available, see page 15. Note : AC voltage requires connector with rectifier. LATCHING SOLENOID OPTIONS 47A-XXJ-XXXP-XXX J Manifold base, side cylinders (middle station) K Manifold base, bottom cylinders (middle station) L Right end manifold base, side cylinders M Right end manifold base, bottom cylinders N Left end manifold base, side cylinders P Left end manifold base, bottom cylinders 1 Non-locking recessed Locking recessed XX Voltage X Manual operator XX DA DF 4 VDC (5.W) 1 VDC (5.W) * Other options available, see page 19. 0 No operator L XX P-XXX * Note: Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds. FA FB FC FD FT FA FB FC FD Electrical connection Base plug-in Base plug-in w/ ground Base plug-in w/ LED light Base plug-in w/ LED light w/ ground Base plug-in w/ rectifier and light Electrical connection Base plug-in w/ ground Base plug-in w/ ground & LED Base plug-in 4 wire w/ ground Base Plug-in 4 wire w/ LED & ground 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 117 Consult Precautions page 7 before use, installation or service of MAC Valves..

1 5 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 47 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Coil : Voltage range : Power : Response times : (with 5, W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.W : (0.50 C v ).4W : (0.5 C v ) 1.0W : (0.0 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 5.W.4W 1.0W Energize : 17.4 ms De-energize :.8 ms Options : Spare parts : BSPP threads Sandwich flow control: FC47A-AA Sandwich regulator: see Regulator section Inlet/exhaust isolator: 8447 Valve cover plate: M-47001 DIMENSIONS Dimensions shown are metric (mm) 11.7 101.0 00.8.7 1.7 19.8 8.0 1 1 1 1 1.5 P 41.9 17.4 14 14 14 14 100.5 6. 1 96. 18.0.5 4.8 P P 5.5 0.8 51.6 /8" N.P.T.F. HOLES BOTH ENDS 78. L 4 4 4 4 OPTIONAL SANDWICH REGULATOR SHOWN 1/"-14 N.P.S.M. CONDUIT BOTH ENDS Ø 5. DIA. 4 MTG. HOLES 1/8" OR 1/4" PORTS AVAILABLE 18.0.5 4.5 4 4 4 P P P P 4 9.0.5 18.0 118 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48P Individual mounting Series Inline Manual operator Solenoid 4 5 1 Bonded spool 4-way pilot with poppet in spool design 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot with poppet inside the spool. Large flow in compact package. Single or dual pressure. Rectified AC voltage. 9 ISO 01 ISO 0 ISO 1 ISO ISO 119 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48P Function Port size Flow (Max) Individual mounting Series 5/ 1/8 1.0 C v Inline OPERATIONAL BENEFITS 1. 4-way valve with 4-way pilot.. Poppet in spool design. 16 mm valve (stacks on 16.5 mm centers). 4. High flow (up to 1.0 Cv). 5. Fast repeatable response times. 6. Maximum shifting forces in both directions. 7. Long life. 8. Compact design. HOW TO ORDER Port size Pilot 5/ Single operator Single pressure 4 1 14 5/ Single operator Dual pressure 14 4 1 4 6 7 8 5 67 69 44 Internal 15 48PB-AAA-A00-GXXX-XXX - 5 1 46 1/8 Internal from port Internal from port 5 - - 48PB-CAB-A00-GXXX-XXX 48PB-CAC-A00-GXXX-XXX 4 STANDARD SOLENOID OPERATOR G XXX-XXX * 47 48P XX Voltage X Wire length X Manual operator XX AA DC DD DF 10 VAC (.5W) 4 VDC (1.8W) 4 VDC (.5W) 4 VDC (4.0W) * Other options available, see page 11. Note : AC voltage requires connector with rectifier. OPTIONS 48PB-X X X-X00-GXX-XXX A Pilot exhaust muffled C Pilot exhaust piped M5 D Pilot exhaust out main exhaust A 18 B 4 C 6 1 Non-locking Locking BA BT GA KA KT KD Electrical connection Flying leads Flying leads with light MAC JAC solenoid plug-in Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48P TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (18 C to +50 C) Cv 1,0 Class A wire continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage 1.0 to 4.0 W Options : BSPP threads DIMENSIONS 11.0 16.0.4 Dimensions shown are metric (mm) 4 8.0 16.0 1/8"- BSPP (5 PLACES) AUCKLAND, N.Z. LIEGE, BELGIUM WIXOM, MI. USA MODIF. VAC TO 150 PSI MODEL 4.7 5.5 56. 1. Ø 4. 8.8 15.5 15.5 5.9 5 1 8.0 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Manual operator Solenoid Individual mounting Sub-base non plug-in Sub-base plug-in Manifold mounting Manifold base non plug-in Manifold base plug-in Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base non plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Sub-base/ manifold base plug-in with latching solenoid Bonded spool Integral 4-way pilot 1 4 5 Air return Series 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. Single or dual pressure. Internal or external pilot. Single or double solenoid. or position. Rectified AC voltage. Latching solenoid technology. 9 ISO 01 ISO 0 ISO 1 ISO ISO 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8 1.1 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (VALVE WITH BASE CODED FOR SIDE PORTS) Port size Pilot air 5/ Single solenoid 4 1 14 5/ Double solenoid 4 1 14 5/ Closed center 1 4 14 5/ Open center 1 4 14 7 8 5 67 69 44 46 Valve less base Internal External 15 48B-AMA-000-GXXX-XXX 48B-AMD-000-GXXX-XXX 15 48B-BMA-000-GXXX-XXX 48B-BMD-000-GXXX-XXX 15 48B-EMA-000-GXXX-XXX 48B-EMD-000-GXXX-XXX 15 48B-FMA-000-GXXX-XXX 48B-FMD-000-GXXX-XXX 4 1/8 NPTF Internal External 48B-AMA-AAL-GXXX-XXX 48B-AMD-AAM-GXXX-XXX 48B-BMA-AAL-GXXX-XXX 48B-BMD-AAM-GXXX-XXX DUAL PRESSURE MODELS (VALVE WITH BASE CODED FOR SIDE PORTS) 48B-EMA-AAL-GXXX-XXX 48B-EMD-AAM-GXXX-XXX 48B-FMA-AAL-GXXX-XXX 48B-FMD-AAM-GXXX-XXX 47 48P Port size Pilot air 5/ Single solenoid 14 4 1 5/ Double solenoid 14 4 1 5/ Pressure center 1 4 14 48 Valve less base 1/8 NPTF Internal External Internal External STANDARD SOLENOID OPERATOR Supply # port Supply #5 port Supply # port Supply #5 port 48B-CMB-000-GXXX-XXX 48B-CMC-000-GXXX-XXX 48B-CMD-000-GXXX-XXX 48B-CMB-AAL-GXXX-XXX 48B-CMC-AAL-GXXX-XXX 48B-CMD-AAM-GXXX-XXX G XXX-XXX * 48B-DMB-000-GXXX-XXX 48B-DMC-000-GXXX-XXX 48B-DMD-000-GXXX-XXX 48B-DMB-AAL-GXXX-XXX 48B-DMC-AAL-GXXX-XXX 48B-DMD-AAM-GXXX-XXX XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DC 4 VDC (1.8W) B 4 Locking recessed BT DD 4 VDC (.5W) C 6 GA DF 4 VDC (4.0W) KA KT KD * Other options available, see page 11. Latching solenoid also available, see page 1. Note : AC voltage requires connector with rectifier. Other options available for the 48 series valves, see page 17. 5 1 5 1 15 48B-HMB-000-GXXX-XXX 48B-HMC-000-GXXX-XXX 48B-HMD-000-GXXX-XXX 48B-HMB-AAL-GXXX-XXX 48B-HMC-AAL-GXXX-XXX 48B-HMD-AAM-GXXX-XXX Electrical connection Flying leads Flying leads with light MAC JAC solenoid plug-in Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

P 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External pilot: vacuum to 10 PSI position : 0 to 10 PSI - position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich Flow controls: FC48B-BB Sandwich regulator: see "regulators" section DIMENSIONS Dimensions shown are metric (mm) 1/8" EXT. PILOT COMMON 9.5 1.5 4.5 16.7 1.0 1/8" PORTS MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 5.0 116.9 APPROX. 5 EP 1 15. 4.9 46.1 69. 4 9.0 50.4. 8.0 6. 9.7 1.9 /8" IN & EXH COMMONS Ø 5. 86.00 APPROX. 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8 1.1 C v Sub-base plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) - VALVE WITH BASE CODED FOR SIDE PORTS Port size Valve less base 1/8 NPTF Port size Valve less base 1/8 NPTF Pilot air Internal External Internal External Internal External Internal External 5/ Single solenoid 4 1 14 15 48B-AMA-000-GXXP-XXX 48B-AMD-000-GXXP-XXX 48B-AMA-AAA-GXXP-XXX 48B-AMD-AAB-GXXP-XXX Pilot air Supply # port Supply #5 port Supply # port Supply #5 port 5/ Double solenoid 4 1 14 15 48B-BME-000-GXXP-XST 48B-BMH-000-GXXP-XST 48B-BME-AAC-GXXP-XST 48B-BMH-AAD-GXXP-XST 5/ Single solenoid 48B-CMB-000-GXXP-XXX 48B-CMC-000-GXXP-XXX 48B-CMD-000-GXXP-XXX 48B-CMB-AAA-GXXP-XXX 48B-CMC-AAA-GXXP-XXX 48B-CMD-AAB-GXXP-XXX 5/ Closed center 1 4 14 15 48B-EME-000-GXXP-XST 48B-EMH-000-GXXP-XST 48B-EME-AAC-GXXP-XST 48B-EMH-AAD-GXXP-XST 5/ Double solenoid 48B-DMF-000-GXXP-XST 48B-DMG-000-GXXP-XST 48B-DMH-000-GXXP-XST 48B-DMF-AAC-GXXP-XST 48B-DMG-AAC-GXXP-XST 48B-DMH-AAD-GXXP-XST 5/ Open center 1 4 14 15 48B-FME-000-GXXP-XST 48B-FMH-000-GXXP-XST 48B-FME-AAC-GXXP-XST 48B-FMH-AAD-GXXP-XST DUAL PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) - VALVE WITH BASE CODED FOR SIDE PORTS STANDARD SOLENOID OPERATOR 14 5/ Pressure center 48B-HMF-000-GXXP-XST 48B-HMG-000-GXXP-XST 48B-HMH-000-GXXP-XST 48B-HMF-AAC-GXXP-XST 48B-HMG-AAC-GXXP-XST 48B-HMH-AAD-GXXP-XST XX Voltage X Manual operator XX Electrical connection AA 10 VAC (.5W) 1 Non-locking recessed Double solenoid & position models DC 4 VDC (1.8W) Locking recessed ST Base plug-in DD 4 VDC (.5W) Single solenoid models DF 4 VDC (4.0W) SA Base plug-in SJ Base plug-in with LED light SS Base plug-in with rectifier & light & ground * Other options available, see page 11. Latching solenoid also available, see page 15. Note : AC voltage requires connector with rectifier (For double solenoid consult factory). Other options available for the 48 series valves, see page 18. 5 4 1 G XX P-XXX * 1 14 5 4 1 1 1 4 14 15 4 6 7 8 5 67 69 44 46 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External pilot: vacuum to 10 PSI position : 0 to 10 PSI - position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich Flow controls: FC48B-AB Sandwich regulator: see "regulators" section DIMENSIONS Dimensions shown are metric (mm) 84.5 44. /8" IN & EXH COMMONS 9.5 1.5. 17.6 6.4 4.0 1.4 16.7 1.0 8.0 9.7 4.1 50.4 1 MODEL EP 5 8.4 51.5 76.0 WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 1/8" EXT. PILOT 7.7 8. 11.0 Ø 5. COND 5.5 18 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ 1/8 1.1 C v Manifold base non plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (MIDDLE STATION MANIFOLDS WITH SIDE PORTS) Port size Pilot air 5/ Single solenoid 4 1 14 5/ Double solenoid 4 1 14 5/ Closed center 1 4 14 5/ Open center 1 4 14 7 8 5 67 69 44 46 Valve less base Internal External 15 48B-AMA-000-GXXX-XXX 48B-AMD-000-GXXX-XXX 15 48B-BMA-000-GXXX-XXX 48B-BMD-000-GXXX-XXX 15 48B-EMA-000-GXXX-XXX 48B-EMD-000-GXXX-XXX 15 48B-FMA-000-GXXX-XXX 48B-FMD-000-GXXX-XXX 4 1/8 NPTF Internal External 48B-AMA-AJL-GXXX-XXX 48B-AMD-AJM-GXXX-XXX 48B-BMA-AJL-GXXX-XXX 48B-BMD-AJM-GXXX-XXX DUAL PRESSURE MODELS (MIDDLE STATION MANIFOLDS WITH SIDE PORTS) 48B-EMA-AJL-GXXX-XXX 48B-EMD-AJM-GXXX-XXX 48B-FMA-AJL-GXXX-XXX 48B-FMD-AJM-GXXX-XXX 47 48P Port size Pilot air 5/ Single solenoid 14 4 1 5/ Double solenoid 14 4 1 5/ Pressure center 1 4 14 48 Valve less base 1/8 NPTF Internal External Internal External STANDARD SOLENOID OPERATOR Supply # port Supply #5 port Supply # port Supply #5 port 48B-CMB-000-GXXX-XXX 48B-CMC-000-GXXX-XXX 48B-CMD-000-GXXX-XXX 48B-CMB-AJL-GXXX-XXX 48B-CMC-AJL-GXXX-XXX 48B-CMD-AJM-GXXX-XXX G XXX-XXX * 48B-DMB-000-GXXX-XXX 48B-DMC-000-GXXX-XXX 48B-DMD-000-GXXX-XXX 48B-DMB-AJL-GXXX-XXX 48B-DMC-AJL-GXXX-XXX 48B-DMD-AJM-GXXX-XXX XX Voltage X Wire length X Manual operator XX AA 10 VAC (.5W) A 18 1 Non-locking recessed BA DC 4 VDC (1.8W) B 4 Locking recessed BT DD 4 VDC (.5W) C 6 GA DF 4 VDC (4.0W) KA KT KD * Other options available, see page 11. Latching solenoid also available, see page 1. Note : - AC voltage requires connector with rectifier. - Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 48 series valves, see page 17. 5 1 5 1 15 48B-HMB-000-GXXX-XXX 48B-HMC-000-GXXX-XXX 48B-HMD-000-GXXX-XXX 48B-HMB-AJL-GXXX-XXX 48B-HMC-AJL-GXXX-XXX 48B-HMD-AJM-GXXX-XXX Electrical connection Flying leads Flying leads with light MAC JAC solenoid plug-in Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External pilot: vacuum to 10 PSI position : 0 to 10 PSI - position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich flow controls: FC48B-BB Sandwich regulator: see "regulators" section Valve blanking plate: M-48004 Isolator disk for inlet/exhaust: 8471 DIMENSIONS Dimensions shown are metric (mm) 1/8" PORTS 4 4 P 4 P 4 17.6 5.7 16.5 96.0 86.8 1/8" EXT. PILOT COMMON 9.5 1.5 4.8 4.7 16.7 1.0 8.0 MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 15.5 116.9 APPROX. 5 EP P 1 15. 4.9 46.1 69. /8" IN & EXH COMMONS 1.5 16.5 Ø 5. 86.00 APPROX. 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ 1/8 1.1 C v Manifold base plug-in OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. 4 6 HOW TO ORDER SINGLE PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) Port size Pilot air 5/ Single solenoid 4 1 14 5/ Double solenoid 4 1 14 5/ Closed center 1 4 14 5/ Open center 1 4 14 7 8 5 67 69 44 46 Valve less base 1/8 NPTF Internal External Internal External 15 48B-AMA-000-GXXP-XXX 48B-AMD-000-GXXP-XXX 48B-AMA-AJA-GXXP-XXX 48B-AMD-AJB-GXXP-XXX 15 48B-BME-000-GXXP-XST 48B-BMH-000-GXXP-XST 48B-BME-AJC-GXXP-XST 48B-BMH-AJD-GXXP-XST DUAL PRESSURE MODELS (LED STANDARD EXCEPT FOR SINGLE SOLENOIDS) 15 48B-EME-000-GXXP-XST 48B-EMH-000-GXXP-XST 48B-EME-AJC-GXXP-XST 48B-EMH-AJD-GXXP-XST 15 48B-FME-000-GXXP-XST 48B-FMH-000-GXXP-XST 48B-FME-AJC-GXXP-XST 48B-FMH-AJD-GXXP-XST 4 47 48P Port size Pilot air 5/ Single solenoid 14 4 1 5/ Double solenoid 14 4 1 5/ Pressure center 1 4 14 48 Valve less base 1/8 NPTF Internal External Internal External STANDARD SOLENOID OPERATOR Supply # port Supply #5 port Supply # port Supply #5 port 48B-CMB-000-GXXP-XXX 48B-CMC-000-GXXP-XXX 48B-CMD-000-GXXP-XXX 48B-CMB-AJA-GXXP-XXX 48B-CMC-AJA-GXXP-XXX 48B-CMD-AJB-GXXP-XXX G XX P-XXX * 48B-DMF-000-GXXP-XST 48B-DMG-000-GXXP-XST 48B-DMH-000-GXXP-XST 48B-DMF-AJC-GXXP-XST 48B-DMG-AJC-GXXP-XST 48B-DMH-AJD-GXXP-XST 48B-HMF-000-GXXP-XST 48B-HMG-000-GXXP-XST 48B-HMH-000-GXXP-XST 48B-HMF-AJC-GXXP-XST 48B-HMG-AJC-GXXP-XST 48B-HMH-AJD-GXXP-XST Above numbers are middle station manifolds with side ports XX Voltage X Manual operator XX Electrical connection AA 10 VAC (.5W) 1 Non-locking recessed Double solenoid & position models DC 4 VDC (1.8W) Locking recessed ST Base plug-in DD 4 VDC (.5W) Single solenoid models DF 4 VDC (4.0W) SA Base plug-in SJ Base plug-in with LED light SS Base plug-in with rectifier & light & ground * Other options available, see page 11. Latching solenoid also available, see page 15. Note : - AC voltage requires connector with rectifier. (For double solenoid consult factory). - Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 48 series valves, see page 18. 5 1 5 1 15 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

1 5 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External pilot: vacuum to 10 PSI position : 0 to 10 PSI - position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich flow controls: FC48B-AB Sandwich regulator: see "regulators" section Valve blanking plate: M-48004 Isolator disk for inlet/exhaust: 8471 Plug-in wire protector: 4180 DIMENSIONS 1.5 16.5. 17.6 Dimensions shown are metric (mm) 8.0 1/8" PORTS 4 4 4 4.1 76.0 /8" IN & EXH COMMONS 84.5 9.5 1.5 4.0 88.0 1.4 16.7 1.0 9.7 8.4 51.5 115.8 EP COND WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL 1/8" EXT. PILOT 7.7 8. 11.0 Ø 5. 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Individual/Manifold mounting Series 5/ 1/8 1.1 C v manifold base non plug-in Sub-base/ with latching solenoid OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base 1/8 NPTF Pilot air Internal External Internal External DUAL PRESSURE MODELS (INDIVIDUAL BASE WITH SIDE PORTS) Port size Pilot air 5/ Single pressure 4 1 14 15 48A-AMA-000-LXXX-XXX 48A-AMD-000-LXXX-XXX 48A-AMA-AAL-LXXX-XXX 48A-AMD-AAM-LXXX-XXX 5/ Dual pressure 4 1 14 4 6 7 8 5 67 69 44 46 4 47 48P 48 Valve less base 1/8 NPTF LATCHING SOLENOID Internal External Internal External Supply # port Supply #5 port Supply # port Supply #5 port L XXX-XXX * 15 48A-CMB-000-LXXX-XXX 48A-CMC-000-LXXX-XXX 48A-CMD-000-LXXX-XXX 48A-CMB-AAL-LXXX-XXX 48A-CMC-AAL-LXXX-XXX 48A-CMD-AAM-LXXX-XXX XX Voltage X Wire length X Manual operator XX DF HA 4 VDC (4.0W) 4 VDC (1.95W) A 18 B 4 C 6 0 No operator BA BJ KA KE LA Electrical connection Wire flying leads 4 Wire flying leads Wire Plug-in assembly 4 Wire Plug-in assembly Wire Plug-in assembly (Polarity Switching Cover) 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO * Other options available, see page 19. Note : Manifold assemblies consist of (1) left end manifold, (1) right end manifold, and middle station manifolds (options "J" or "K"). Other options available for the 48 series valves, see page 17. 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

5 1 1 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 48 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot: vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich flow controls: FC48B-BB Sandwich regulator: see "regulators" section Valve blanking plate: M-48004 Isolator disk for inlet/exhaust: 8471 DIMENSIONS Individual base 1/8" EXT. PILOT COMMON Dimensions shown are metric (mm) Manifold base 9.5 1.5 4.5 16.7 1.0 1/8" PORTS MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI 5.0 15.5 APPROX. 5 EP P 15. 4.9 46.1 69. 17.6 4 4 4 P P 16.5 5.7 96.0 4 50.4 6. 9.7 Ø 5. 86.00 APPROX. /8" IN & EXH COMMONS 4.8 4.7 86.8 1/8" EXT. PILOT COMMON 9.5 1.5 16.7 1.0 EP 15. 4.9 MODEL MODEL MODEL MODEL 46.1 1/8" PORTS 8.0 WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. MODIF. VAC TO 150 PSI WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 15.5 APPROX. 69. P 4 8.0 9.0 1.5 16.5 Ø 5. 86.00 APPROX. /8" IN & EXH COMMONS. 14 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 Function Port size Flow (Max) Individual/Manifold mounting Series 5/ 1/8 1.1 C v manifold base plug-in Sub-base/ with latching solenoid OPERATIONAL BENEFITS 1. 4-way valve with 4-way integral pilot.. 16 mm valve (stacks on 16.5 mm centers).. High flow (up to 1.1 C v ). 4. Fast repeatable response times. 5. Maximum shifting forces in both directions. 6. Long life. HOW TO ORDER SINGLE PRESSURE MODELS (-WIRE INDIVIDUAL BASE WITH SIDE PORTS) Port size Valve less base 1/8 NPTF Pilot air Internal External Internal External DUAL PRESSURE MODELS (-WIRE INDIVIDUAL BASE WITH SIDE PORTS) Port size Pilot air 5/ Single pressure 4 1 14 15 48A-AMA-000-LXXP-XXX 48A-AMD-000-LXXP-XXX 48A-AMA-AAA-LXXP-XXX 48A-AMD-AAB-LXXP-XXX 5/ Dual pressure 4 1 14 4 6 7 8 5 67 69 44 46 4 47 48P 48 Valve less base 1/8 NPTF LATCHING SOLENOID Internal External Internal External Supply # port Supply #5 port Supply # port Supply #5 port 15 48A-CMB-000-LXXP-XXX 48A-CMC-000-LXXP-XXX 48A-CMD-000-LXXP-XXX 48A-CMB-AAA-LXXP-XXX 48A-CMC-AAA-LXXP-XXX 48A-CMD-AAB-LXXP-XXX XX Voltage X Manual operator XX DF DN HA HE 4 VDC (4.0W) 1 VDC (4.0W) 4 VDC (1.95W) 1 VDC (1.95W) 0 No operator L XX P-XXX * * Other options available, see page 19. ** For latching solenoid and 4 wire, use electrical connector DA, DB, DC or DD. For wire latching, use the "EA" connector. Other options available for the 48 series valves, see page 18. DA EA Electrical connection** Plug-in Plug-in PIN (Polarity Switching Cover) 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICAL DATA DIMENSIONS Dimensions shown are metric (mm) Manifold base 6.4 4.0 /8" IN & EXH COMMONS 9.5 1.5 16.7 1.0 9.7 50.4 1/8" EXT. PILOT 8.4 51.5 7.7 8. 11.0 MODEL EP 1 1 5 5 Series 48 Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot: vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" side ports: (1.0 C v ) 1/8" bottom ports : (1.1 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 6 ms De-energize : 6 ms Options : BSPP threads 1/4 O.D. pressed in tube receptacles Sandwich flow controls: FC48B-AB Sandwich regulator: see "regulators" section Valve blanking plate: M-48004 Isolator disk for inlet/exhaust: 8471 Plug-in wire protector : 4180 Individual base 44.. 17.6 1.5 16.5. 17.6 8.0 8.0 4.1 1/8" PORTS 4 4 4 4.1 76.0 76.0 9.5 4.0 88.0 9.7 /8" IN & EXH COMMONS 1.5 16.7 1.0 8.4 WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. 115.8 WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL 1/8" EXT. PILOT EP 51.5 7.7 8. 11.0 Ø 5. COND WIXOM, MI. USA MODIF. VAC TO 150 PSI LIEGE, BELGIUM AUCKLAND, N.Z. MODEL Ø 5. 5.5 COND 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 OPTIONS FOR NON PLUG-IN VALVES Base type : Individual base 48B-XXX-XAX-GXXX-XXX Universal spool 48B-RXX-XXX-GXXX-XXX Base only : 48B-000-XXX (i.e. 48B-000-AAL) Pilot style : 48B-XMX-XXX-GXXX-XXX A Individual base Side ports B Individual base Bottom ports R position single solenoid universal spool S position double solenoid universal spool M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust - Individual base Manifold base 48B-XXX-XJX-GXXX-XXX J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports 48B-000-XXX (i.e. 48B-000-AJL) - Manifold base 4 6 7 8 5 67 69 44 46 4 47 48P Base/Manifold configurations for LATCHING SOLENOID VALVES : 48A-XXX-XAX-LXXX-XXX A Individual base Side ports B Individual base Bottom ports J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 48 OPTIONS FOR PLUG-IN VALVES Base type : Individual base 48B-XXX-XAX-GXXP-XXX A Individual base Side ports B Individual base Bottom ports Manifold base 48B-XXX-XJX-GXXP-XXX J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports Universal spool 48B-RXX-XXX-GXXP-XXX R position single solenoid universal spool S position double solenoid universal spool Base only : 48B-000-XXX (i.e. 48B-000-AAA) - Individual base wired for a single solenoid valve 48B-000-XXX (i.e. 48B-000-AJC) - Manifold base wired for a double solenoid valve For LED with diode ( & position double solenoid valves) 48B-XXJ-XXX-GXXP-XST J Internal pilot single pressure K Internal pilot dual pressure supply from # port L Internal pilot dual pressure supply from #5 port M External pilot Pilot style : 48B-XMX-XXX-GXXP-XXX M Pilot exhaust muffled P Pilot exhaust piped (# 10-) U Pilot exhaust to main exhaust Base/Manifold configurations for LATCHING SOLENOID VALVES : 48A-XXX-XAX-LXXP-XXX A Individual base Side ports B Individual base Bottom ports J Manifold base Side ports K Manifold base Bottom ports L Left end manifold base Side ports M Left end manifold base Bottom ports N Right end manifold base Side ports P Right end manifold base Bottom ports Base/Manifold options for int./ext. pilot for LATCHING SOLENOID VALVES : 48A-XXX-XXA-LXXP-XXX A Plug-in Int. Pilot Wire Latching B Plug-in Ext. Pilot Wire Latching C Plug-in Int. Pilot Wire Latching D Plug-in Ext. Pilot Wire Latching E Plug-in Int. Pilot 4 Wire Latching F Plug-in Ext. Pilot 4 Wire Latching 18 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 400 Individual mounting Series Inline Sub-base non plug-in 4 6 Air return Manual operator Solenoid 4-way pilot with balanced poppet Bonded spool 4 7 8 5 67 69 44 46 4 47 48P 1 5 48 400 9 SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Various manual operators. Optional memory spring. position or position valve configurations. Internal or external pilot. 9 ISO 01 ISO 0 ISO 1 ISO ISO 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 SPOOL CONFIGURATIONS INTERNAL PILOT EXTERNAL PILOT EXT. PILOT PORT 1 4 14 1 4 14 1 5 1 5 SINGLE OPERATOR - SINGLE INLET SHOWN WITH 1 OPERATOR ENERGIZED SINGLE OPERATOR - SINGLE INLET SHOWN WITH 1 OPERATOR ENERGIZED INTERNAL PILOT (FROM #5 PORT) INTERNAL PILOT 1 4 14 1 4 14 1 5 1 5 SINGLE OPERATOR - DUAL INLET SHOWN WITH 1 OPERATOR ENERGIZED POSITION CLOSED CENTER INTERNAL PILOT INTERNAL PILOT 1 4 14 1 4 14 1 5 1 5 POSITION OPEN CENTER POSITION PRESSURE CENTER 140 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8-1/4 1.0 C v Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF Pilot air Internal External 5/ Single operator 4 1 14 15 411A-A0A-XX-XXXX-XXX 411A-B0A-XX-XXXX-XXX 411A-A0B-XX-XXXX-XXX 411A-B0B-XX-XXXX-XXX 5/ Double operator 4 1 14 15 41A-A0A-XX-XXXX-XXX 41A-B0A-XX-XXXX-XXX 41A-A0B-XX-XXXX-XXX 41A-B0B-XX-XXXX-XXX 5/ Closed center 1 4 14 451A-A0A-XX-XXXX-XXX 451A-B0A-XX-XXXX-XXX 451A-A0B-XX-XXXX-XXX 451A-B0B-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM #5 PORT) Port size Pilot air 15 5/ Single operator 4 1 14 5/ Open center 1 4 14 15 461A-A0A-XX-XXXX-XXX 461A-B0A-XX-XXXX-XXX 461A-A0B-XX-XXXX-XXX 461A-B0B-XX-XXXX-XXX 5/ Double operator 4 1 14 5/ Pressure center 1 4 14 15 471A-A0A-XX-XXXX-XXX 471A-B0A-XX-XXXX-XXX 471A-A0B-XX-XXXX-XXX 471A-B0B-XX-XXXX-XXX 4 6 7 8 5 67 69 44 46 4 47 48P 48 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF SOLENOID OPERATOR Internal External 41A-A0A-XX-XXXX-XXX 41A-B0A-XX-XXXX-XXX 41A-A0B-XX-XXXX-XXX 41A-B0B-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 (.9W) A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) B 4 (Flying leads) Locking recessed KD JC 4/60 (.9W) J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) DF 4 VDC (1.7W) BA SOLENOID OPERATOR 15 GM-G XXX-XXX ** 15 441A-A0A-XX-XXXX-XXX 441A-B0A-XX-XXXX-XXX 441A-A0B-XX-XXXX-XXX 441A-B0B-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX DC DD DF 4VDC (1.8W) 4VDC (.5W) 4VDC (4.0W) * Other options available, see page 09. ** Other options available, see page 1. A 18 B 4 C 6 1 Non-locking recessed Locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 141 Consult Precautions page 7 before use, installation or service of MAC Valves..

7 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot pos. : 0 to 10 PSI (with memory spring: 0 to 10 PSI) pos.: 5 to 10 PSI External pilot : vacuum to 10 PSI position: 0 to 10 PSI (with memory spring: 0 to 10 PSI) position: 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.0 C v Class A continuous duty, # AWG x 1 leads wires -15% to +10% of nominal voltage Consult factory ~Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 1.7 W 4 V=/5.4W Energize : 7. ms De-energize : 5. ms 10/60 Energize : 8-1 ms De-energize : 7-11 ms Options : Spare parts : BSPP threads Namur interface (specify mod. 1080 after model) 411A-A0A-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For memory spring, replace by 4 (single operator models only) Replace by 8 for position dual pressure, pressure center DM pilot body pressure seal: 1654 DM pilot spacer plate: 4168-01. DIMENSIONS.5 DIA. MTG. HOLES, () 15.0 DOUBLE PILOT (DM) SIMPLE 96.0 PILOT (DM) Dimensions shown are metric (mm).0 5.0 4.5 PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 15.5 4 7.8 9. 18.7 44.0 9.0 0.5 PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 17.5 DOUBLE PILOT W/ PLUG-IN (GM) SINGLE PILOT W/ PLUG-IN (GM) 10. DOUBLE PILOT 11.0 W/ FLYING LEADS (GM) OPTIONAL MANUAL OPERATOR SINGLE PILOT W/ FLYING LEADS (GM) 99.0 17.0 4.5 DIA. MTG. HOLES, () 60. PILOT W/ GM SOLENOID 6.0 6.5 PILOT W/ DM SOLENOID 5.0 1.0 10.5 9.8 4.7 51. PILOT W/ GM SOLENOID PILOT W/ DM SOLENOID 18.0 18.0 4.0 4.5 PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 1 5 14 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8-1/4 1.0 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Valve only 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF Pilot air Internal External Internal External 5/ Single operator 4 1 14 15 41A-00A-XX-XXXX-XXX 41A-00D-XX-XXXX-XXX 41A-AAA-XX-XXXX-XXX 41A-BAA-XX-XXXX-XXX 41A-AAD-XX-XXXX-XXX 41A-BAD-XX-XXXX-XXX 5/ Double operator 4 1 14 15 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX 5/ Closed center 1 4 14 45A-00A-XX-XXXX-XXX 45A-00D-XX-XXXX-XXX 45A-AAA-XX-XXXX-XXX 45A-BAA-XX-XXXX-XXX 45A-AAD-XX-XXXX-XXX 45A-BAD-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM #5 PORT) Port size Pilot air 15 5/ Single operator 4 1 14 5/ Open center 1 4 14 15 46A-00A-XX-XXXX-XXX 46A-00D-XX-XXXX-XXX 46A-AAA-XX-XXXX-XXX 46A-BAA-XX-XXXX-XXX 46A-AAD-XX-XXXX-XXX 46A-BAD-XX-XXXX-XXX 5/ Pressure center 1 4 14 15 47A-00A-XX-XXXX-XXX 47A-00D-XX-XXXX-XXX 47A-AAA-XX-XXXX-XXX 47A-BAA-XX-XXXX-XXX 47A-AAD-XX-XXXX-XXX 47A-BAD-XX-XXXX-XXX 5/ Double operator 4 1 14 4 6 7 8 5 67 69 44 46 4 47 48P 48 Valve only 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF SOLENOID OPERATOR Internal External Internal External 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 (.9W) A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) B 4 (Flying leads) Locking recessed KD JC 4/60 (.9W) J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) DF 4 VDC (1.7W) BA SOLENOID OPERATOR 15 GM-G XXX-XXX ** 15 44A-00A-XX-XXXX-XXX 44A-00D-XX-XXXX-XXX 44A-AAA-XX-XXXX-XXX 44A-BAA-XX-XXXX-XXX 44A-AAD-XX-XXXX-XXX 44A-BAD-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX DC DD DF 4VDC (1.8W) 4VDC (.5W) 4VDC (4.0W) * Other options available, see page 09. ** Other options available, see page 1. A 18 B 4 C 6 1 Non-locking recessed Locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 14 Consult Precautions page 7 before use, installation or service of MAC Valves..

5 TO 10 PSI 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot pos. : 0 to 10 PSI (with memory spring: 0 to 10 PSI) pos.: 5 to 10 PSI External pilot : vacuum to 10 PSI position: 0 to 10 PSI (with memory spring: 0 to 10 PSI) position: 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.0 C v Class A continuous duty, # AWG x 1 leads wires -15% to +10% of nominal voltage Consult factory ~Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 1.7 W 4 V=/5.4W Energize : 7. ms De-energize : 5. ms 10/60 Energize : 8-1 ms De-energize : 7-11 ms Options : BSPP threads 41A-AAA-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For flow control, replace by B For memory spring, replace by 6 Base only : 400A-XXX (i.e. 400A-AAA) Spare parts : Body to base seal: 1655 Flow control assembly: N-04001 Body mounting screws (x): 504. DIMENSIONS Dimensions shown are metric (mm) 86. EXTENDED OPERATOR 97.9 LOCKNING OPERATOR 81.4 C L C L 4 19.05 STOCK REF. 1.0 0.0 108.5 SINGLE PILOT 1/8" - 7 N.P.T.F. 1/4" - 18 N.P.T.F. TYPICAL OPTIONAL FLOW CONTROL 15.0 DOUBLE PILOT 6.0 1.0 1 14 10.0 8.1 1 14 5 1 4 8.10.1 11.9 9.5 REF. 4.0 DIA. () MIG. HOLES 5.0 47.00 OPTIONAL EXTERNAL PILOT PORT (#10- UNF-8) 6.5 144 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Individual mounting Series Sub-base non plug-in Sub-base plug-in Manifold mounting Sub-base non plug-in Sub-base plug-in Optional light Plug-in solenoid Manual operator Solenoid 4 6 7 8 5 67 69 44 46 Bonded spool 4 Air return EXH. B IN. A EXH. EXH. 47 48P 48 IN. 4-way pilot with balanced poppet SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Optional memory spring. Plug-in design of valves and bases for ease of maintenance. position or position valve configurations. 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 145 Consult Precautions page 7 before use, installation or service of MAC Valves..

EXH. B IN. A EXH. IN B EXH. A IN 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 SPOOL CONFIGURATIONS B A B A EXH B IN A EXH POSITION SINGLE PRESSURE SHOWN WITH "B" OPERATOR ENERGIZED IN B EXH POSITION DUAL PRESSURE SHOWN WITH "B" OPERATOR ENERGIZED A IN B A A EXH B IN A EXH POSITION CLOSED CENTER SPRING CENTERING EXH B IN A EXH POSITION OPEN CENTER B A REGULATOR CONFIGURATIONS SINGLE REGULATOR - SINGLE PRESSURE Pressure supplied to the individual or manifold base passes through the regulator. Regulated pressure is supplied to the pressure path of the valve. EXH B IN A EXH POSITION SINGLE PRESSURE, PRESSURE CENTER DUAL REGULATOR - DUAL PRESSURE Pressure supplied from each regulator is divided in the block. Regulated pressure from A regulator supplies cylinder port A. Regulated pressure from B regulator supplies cylinder port B. Dual pressure regulators require dual pressure spool in valve. MANIFOLD WITH REGULATOR - SINGLE PRESSURE Note: For both single and dual pressure, air supply to the pilot system is never regulated. MANIFOLD WITH REGULATOR - DUAL PRESSURE 146 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8-1/4 - /8 1. C v Sub-base non plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded seal spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow; short and consistent response times. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 6 7 8 5 67 69 44 46 Valve less base 1/8 NPTF 1/4 NPTF /8 NPTF 1/8 NPTF 1/4 NPTF /8 NPTF Internal External SOLENOID OPERATOR 9B-ABA-000-DM-DXXX-XXX 9B-ABA-AAG-DM-DXXX-XXX 9B-ABA-BAG-DM-DXXX-XXX 9B-ABA-CAG-DM-DXXX-XXX 9B-ABA-AAH-DM-DXXX-XXX 9B-ABA-BAH-DM-DXXX-XXX 9B-ABA-CAH-DM-DXXX-XXX 9B-BBA-000-DM-DXXX-XXX 9B-BBA-AAG-DM-DXXX-XXX 9B-BBA-BAG-DM-DXXX-XXX 9B-BBA-CAG-DM-DXXX-XXX 9B-BBA-AAH-DM-DXXX-XXX 9B-BBA-BAH-DM-DXXX-XXX 9B-BBA-CAH-DM-DXXX-XXX DM-D XXX-XXX * 9B-EBA-000-DM-DXXX-XXX 9B-EBA-AAG-DM-DXXX-XXX 9B-EBA-BAG-DM-DXXX-XXX 9B-EBA-CAG-DM-DXXX-XXX 9B-EBA-AAH-DM-DXXX-XXX 9B-EBA-BAH-DM-DXXX-XXX 9B-EBA-CAH-DM-DXXX-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR SEE "REGULATORS" SECTION) Port size Valve less base 1/8 NPTF 1/4 NPTF /8 NPTF 1/8 NPTF 1/4 NPTF /8 NPTF Pilot air Internal External 5/ Single operator 9B-CBA-000-DM-DXXX-XXX 9B-CBA-AAG-DM-DXXX-XXX 9B-CBA-BAG-DM-DXXX-XXX 9B-CBA-CAG-DM-DXXX-XXX 9B-CBA-AAH-DM-DXXX-XXX 9B-CBA-BAH-DM-DXXX-XXX 9B-CBA-CAH-DM-DXXX-XXX 9B-FBA-000-DM-DXXX-XXX 9B-FBA-AAG-DM-DXXX-XXX 9B-FBA-BAG-DM-DXXX-XXX 9B-FBA-CAG-DM-DXXX-XXX 9B-FBA-AAH-DM-DXXX-XXX 9B-FBA-BAH-DM-DXXX-XXX 9B-FBA-CAH-DM-DXXX-XXX 9B-GBA-000-DM-DXXX-XXX 9B-GBA-AAG-DM-DXXX-XXX 9B-GBA-BAG-DM-DXXX-XXX 9B-GBA-CAG-DM-DXXX-XXX 9B-GBA-AAH-DM-DXXX-XXX 9B-GBA-BAH-DM-DXXX-XXX 9B-GBA-CAH-DM-DXXX-XXX 5/ Double operator 9B-DBA-000-DM-DXXX-XXX 9B-DBA-AAG-DM-DXXX-XXX 9B-DBA-BAG-DM-DXXX-XXX 9B-DBA-CAG-DM-DXXX-XXX 9B-DBA-AAH-DM-DXXX-XXX 9B-DBA-BAH-DM-DXXX-XXX 9B-DBA-CAH-DM-DXXX-XXX Above models are shown with side ports. 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX Electrical connection JA 110 /50, 10/60 (.9W) A 18 (Flying leads) 1 Non-locking recessed BM Flying leads JB 0/50, 40/60 (.9W) B 4 (Flying leads) Locking recessed BN Flying leads with diode JC 4/60 (.9W) J Connector BP Flying leads with M.O.V. FB 4 VDC (1.8W) BG Flying leads with ground DA 4 VDC (5.4W) JB Rectangular connector DF 4 VDC (1.7W) JD Rectangular connector with light * Other options available, see page 09. KA Square connector Other options available for the 9 series valves, see page 155. 147 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 0 to 10 PSI position : 5 to 10 PSI External pilot : vacuum to 10 PSI position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8": (1.0 C v ) 1/4": (1.1 C v ) /8": (1. C v ) Class A continuous duty, # AWG x 18 lead wire -15% to +10% of nominal voltage Consult factory ~Inrush 7.6 VA Holding : 4.8 VA = 1.8 to 1.7 W 4V=/5.4W Energize : 8 ms De-energize : 7 ms 10/60 Energize : 7-1 ms De-energize : 1-0 ms Options : Spare parts : BSPP threads Sandwich flow control: FC9B-CA Pilot valve DM-Dxxx-xxx Valve blanking plate: M-900 Pressure seal between valve and base : 1654. Mounting screws valve to base (X) : 5050. DIMENSIONS 145. Double operator 115.8 Single operator Dimensions shown are metric (mm) 1/8" external pilot port 97,5.0 9.0 1.0 B A E F 84.5 6.0 0.0 40.0 C D 55.6. 15.0 4.0 G 14.5 1/" NPSM conduit connection 1.0 9.5 4.0 76.0 16.0.0 4.5 dia. Mtg Holes 4.5 4.8 DIM. A B C D E F G 1/8" 1.5 18.0 1.0 54.0.5 46.5 18.0 1/4" 1.5 18.0 1.0 54.0.5 46.5 18.0 /8" 1.0 17.0 0.0 54.0.5 47.5 17.0 148 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/8-1/4 - /8 1. C v Sub-base plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded seal spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow; short and consistent response times. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 6 7 8 5 67 69 44 46 Valve less base 1/8 1/4 /8 1/8 1/4 /8 Internal External 9B-AAA-000-DM-DXXP-XXX 9B-AAA-AAA-DM-DXXP-XXX 9B-AAA-BAA-DM-DXXP-XXX 9B-AAA-CAA-DM-DXXP-XXX 9B-AAA-AAD-DM-DXXP-XXX 9B-AAA-BAD-DM-DXXP-XXX 9B-AAA-CAD-DM-DXXP-XXX 9B-BAA-000-DM-DXXP-XXX 9B-BAA-AAA-DM-DXXP-XXX 9B-BAA-BAA-DM-DXXP-XXX 9B-BAA-CAA-DM-DXXP-XXX 9B-BAA-AAD-DM-DXXP-XXX 9B-BAA-BAD-DM-DXXP-XXX 9B-BAA-CAD-DM-DXXP-XXX 9B-EAA-000-DM-DXXP-XXX 9B-EAA-AAA-DM-DXXP-XXX 9B-EAA-BAA-DM-DXXP-XXX 9B-EAA-CAA-DM-DXXP-XXX 9B-EAA-AAD-DM-DXXP-XXX 9B-EAA-BAD-DM-DXXP-XXX 9B-EAA-CAD-DM-DXXP-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR SEE "REGULATORS" SECTION) Port size Valve less base 1/8 1/4 /8 1/8 1/4 /8 SOLENOID OPERATOR Pilot air Internal External 5/ Single operator 9B-CAA-000-DM-DXXP-XXX 9B-CAA-AAA-DM-DXXP-XXX 9B-CAA-BAA-DM-DXXP-XXX 9B-CAA-CAA-DM-DXXP-XXX 9B-CAA-AAD-DM-DXXP-XXX 9B-CAA-BAD-DM-DXXP-XXX 9B-CAA-CAD-DM-DXXP-XXX DM-D XX P-XXX * 9B-FAA-000-DM-DXXP-XXX 9B-FAA-AAA-DM-DXXP-XXX 9B-FAA-BAA-DM-DXXP-XXX 9B-FAA-CAA-DM-DXXP-XXX 9B-FAA-AAD-DM-DXXP-XXX 9B-FAA-BAD-DM-DXXP-XXX 9B-FAA-CAD-DM-DXXP-XXX 9B-GAA-000-DM-DXXP-XXX 9B-GAA-AAA-DM-DXXP-XXX 9B-GAA-BAA-DM-DXXP-XXX 9B-GAA-CAA-DM-DXXP-XXX 9B-GAA-AAD-DM-DXXP-XXX 9B-GAA-BAD-DM-DXXP-XXX 9B-GAA-CAD-DM-DXXP-XXX 5/ Double operator 9B-DAA-000-DM-DXXP-XXX 9B-DAA-AAA-DM-DXXP-XXX 9B-DAA-BAA-DM-DXXP-XXX 9B-DAA-CAA-DM-DXXP-XXX 9B-DAA-AAD-DM-DXXP-XXX 9B-DAA-BAD-DM-DXXP-XXX 9B-DAA-CAD-DM-DXXP-XXX Above models are shown with side ports. 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Manual operator XX JA JB JC FB DA DF 110 /50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) 1 Non-locking recessed Locking recessed DM DN DP DG DJ DH Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground Plug-in with M.O.V. & ground Plug-in with diode & ground * Other options available, see page 09. Note: Ground required for 0 Volts or higher. Other options available for the 9 series valves, see page 156. 149 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 0 to 10 PSI position : 5 to 10 PSI External pilot : vacuum to 10 PSI position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8": (1.0 C v ) 1/4": (1.1 C v ) /8": (1. C v ) Class A continuous duty, # AWG x 18 lead wire -15% to +10% of nominal voltage Consult factory ~Inrush 7.6 VA Holding : 4.8 VA = 1.8 to 1.7 W 4V=/5.4W Energize : 8 ms De-energize : 7 ms 10/60 Energize : 7-1 ms De-energize : 1-0 ms Options : Spare parts : BSPP threads Sandwich flow control: FC9B-AA (sgl. operator), FC9B-BA (dbl. operator) Pilot valve DM-DxxP-xxx Valve blanking plate: M-900 Pressure seal between valve and base : 1654. Mounting screws valve to base (X) : 5050. DIMENSIONS 145. Double operator 115. Single operator Dimensions shown are metric (mm) 1/8" external pilot port 97,5.0 9.0 1.0 B A E F 84.5 6.0 0.0 40.0 C D 55.6. 4.9 15.0 4.0 G 14.5 1/" NPSM conduit connection 1.0 9.5 4.0 76.0 16.0.0 4.5 dia. Mtg Holes 4.5 4.8 DIM. A B C D E F G 1/8" 1.5 18.0 1.0 54.0.5 46.5 18.0 1/4" 1.5 18.0 1.0 54.0.5 46.5 18.0 /8" 1.0 17.0 0.0 54.0.5 47.5 17.0 150 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ 1/4 - /8 1. C v Sub-base non plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded seal spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow; short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 6 7 8 5 67 69 44 46 Valve less base 1/4 NPTF /8 NPTF Internal SOLENOID OPERATOR 9B-ABA-000-DM-DXXX-XXX 9B-ABA-BJG-DM-DXXX-XXX 9B-ABA-CJG-DM-DXXX-XXX 9B-BBA-000-DM-DXXX-XXX 9B-BBA-BJG-DM-DXXX-XXX 9B-BBA-CJG-DM-DXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 110 /50, 10/60 (.9W) A 18 (flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) J Connector Locking recessed KD JC 4/60 (.9W) JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) BA DF 4 VDC (1.7W) BK * Other options available, see page 09. End plate kit required (port size /8"): M-9004-01-01 (internal pilot) M-9004-0-01 (External pilot) Other options available for the 9 series valves, see page 155. 9B-EBA-000-DM-DXXX-XXX 9B-EBA-BJG-DM-DXXX-XXX 9B-EBA-CJG-DM-DXXX-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR SEE "REGULATORS" SECTION) Port size Valve less base 1/4 NPTF /8 NPTF Pilot air Internal 5/ Single operator 9B-CBA-000-DM-DXXX-XXX 9B-CBA-BJG-DM-DXXX-XXX 9B-CBA-CJG-DM-DXXX-XXX 9B-FBA-000-DM-DXXX-XXX 9B-FBA-BJG-DM-DXXX-XXX 9B-FBA-CJG-DM-DXXX-XXX 9B-GBA-000-DM-DXXX-XXX 9B-GBA-BJG-DM-DXXX-XXX 9B-GBA-CJG-DM-DXXX-XXX 5/ Double operator 9B-DBA-000-DM-DXXX-XXX 9B-DBA-BJG-DM-DXXX-XXX 9B-DBA-CJG-DM-DXXX-XXX Above models are shown with side ports. Electrical connection Square connector Square connector with light Rectangular connector Rect. connector with light Flying leads Flying leads with diode 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 151 Consult Precautions page 7 before use, installation or service of MAC Valves..

MODEL ELECTRICAL WIXOM,MI. USA AUCKLAND,N.Z. LIEGE,BELGIUM VAC TO 10 PSI WATTS MODIF. 100 % O F P R O D U C T I O N T E S T E D WARRANTY 18 100 % M O NTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 0 to 10 PSI position : 5 to 10 PSI External pilot : vacuum to 10 PSI position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/4": (1.1 C v ) /8": (1. C v ) Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~Inrush 7.6 VA Holding : 4.8 VA = 1.8 to 1.7 W 4V=/5.4W Energize : 8 ms De-energize : 7 ms 10/60 Energize : 7-1 ms De-energize : 1-0 ms Options : Spare parts : BSPP threads Sandwich flow controls: FC9B-CA Pilot valve: DM-Dxxx-xxx Valve blanking plate: M-900 Pressure seal, valve to base 1654 Inlet/Exhaust isolator disc: N-9018. DIMENSIONS Dimensions shown are metric (mm) A A A 148. WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO XXX PSI WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL MODEL VAC TO XXX PSI MODEL WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO XXX PSI 87.0 Ø 6. B B B 5.5 9.0 14.0 5.0 15.0.0 118.7 EXT.P.0 11.0 B A B A B A 4.0 5.5 6.5 1.5 EB 5.5 7.0 51. 7.1 IN 115.5 EA COND 5.6 6.5 8.5 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ 1/4 - /8 1. C v Sub-base plug-in OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways.. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded seal spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow; short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 6 7 8 5 67 69 44 46 Valve less base 1/4 NPTF /8 NPTF Internal 9B-AAA-000-DM-DXXP-XXX 9B-AAA-BJA-DM-DXXP-XXX 9B-AAA-CJA-DM-DXXP-XXX * Other options available, see page 09. Note: Ground required for 0 Volts or higher. End plate kit required (port size /8"): M-9004-01-01 (internal pilot) M-9004-0-01 (external pilot) Other options available for the 9 series valves, see page 156. 9B-BAA-000-DM-DXXP-XXX 9B-BAA-BJA-DM-DXXP-XXX 9B-BAA-CJA-DM-DXXP-XXX 9B-EAA-000-DM-DXXP-XXX 9B-EAA-BJA-DM-DXXP-XXX 9B-EAA-CJA-DM-DXXP-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR SEE "REGULATORS" SECTION) Port size Valve less base 1/4 NPTF /8 NPTF SOLENOID OPERATOR Pilot air Internal 5/ Single operator 9B-CAA-000-DM-DXXP-XXX 9B-CAA-BJA-DM-DXXP-XXX 9B-CAA-CJA-DM-DXXP-XXX XX Voltage X Manual operator XX JA JB JC FB DA DF 110 /50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) DM-D XX P-XXX * 1 Non-locking recessed Locking recessed 9B-FAA-000-DM-DXXP-XXX 9B-FAA-BJA-DM-DXXP-XXX 9B-FAA-CJA-DM-DXXP-XXX 9B-GAA-000-DM-DXXP-XXX 9B-GAA-BJA-DM-DXXP-XXX 9B-GAA-CJA-DM-DXXP-XXX 5/ Double operator 9B-DAA-000-DM-DXXP-XXX 9B-DAA-BJA-DM-DXXP-XXX 9B-DAA-CJA-DM-DXXP-XXX Above models are shown with side ports and no lights. DM DN DP DG DJ DH Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground Plug-in with M.O.V. & ground Plug-in with diode & ground 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

MODEL ELECTRICAL WIXOM,MI. USA AUCKLAND,N.Z. LIEGE,BELGIUM VAC TO 10 PSI WATTS MODIF. 100 % O F P R O D U C T I O N T E S T E D WARRANTY 18 100 % M O NTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 0 to 10 PSI position : 5 to 10 PSI External pilot : vacuum to 10 PSI position : 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/4": (1.1 C v ) /8": (1. C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult factory ~Inrush 7.6 VA Holding : 4.8 VA = 1.8 to 1.7 W 4V=/5.4W Energize : 8 ms De-energize : 7 ms 10/60 Energize : 7-1 ms De-energize : 1-0 ms Options : Spare parts : BSPP threads Sandwich flow controls: FC9B-AA (sgl. operator), FC9B-BA (dbl. operator) Pilot valve: DM-DxxP-xxx Valve blanking plate: M-900 Pressure seal, valve to base: 1654 Mounting screws valve to base (x): 5050 Inlet/Exhaust isolator disc: N-9018. DIMENSIONS Dimensions shown are metric (mm) A A A 148. WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO XXX PSI WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL MODEL VAC TO XXX PSI MODEL WIXOM,MI.USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO XXX PSI 87.0 Ø 6. B B B 5.5 9.0 14.0 5.0 15.0.0 118.7 EXT.P.0 11.0 B A B A B A 4.0 5.5 6.5 1.5 EB 5.5 7.0 51. 7.1 IN 115.5 EA COND 5.6 6.5 8.5 154 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 OPTIONS FOR NON PLUG-IN VALVES Valve function 9B-HXX-XXX-XX-DXXX-XXX Pilot exhaust 9B-XBX-XXX-XX-DXXX-XXX Port configuration : Individual sub-base H for position dual pressure, pressure center* J for position dual pressure, closed center* K for position dual pressure, open center* L for single operator, single pressure with memory spring N for single operator, dual pressure with memory spring* B standard pilot exhaust D pilot exhaust to main valve exhaust** 9B-XXX-XAX-XX-DXXX-XXX Manifold sub-base 9B-XXX-XJX-XX-DXXX-XXX 4 6 7 8 5 67 69 44 46 Pilot style : 9B-XXX-XXX-DM-DXXX-XXX A side ports B bottom ports (1/8" only) C side & bottom ports (1/8" only) D side inlet & exhaust with bottom cylinder ports (1/8") DM pilot exhaust muffled DP pilot exhaust piped (#10-) DU pilot exhaust to main exhaust J side ports K bottom ports 4 47 48P 48 Base only : 9B-000-XXX (i.e. 9B-000-AAG) - Individual base 9B-000-XXX (i.e. 9B-000-BJG) - Manifold base 400 9 * Requires sandwich regulator. ** Must use DU pilot. Main valve exhaust cannot be restricted. 9 ISO 01 ISO 0 ISO 1 ISO ISO 155 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 OPTIONS FOR PLUG-IN VALVES Valve function 9B-HXX-XXX-XX-DXXP-XXX Pilot exhaust 9B-XAX-XXX-XX-DXXP-XXX H for position dual pressure, pressure center* J for position dual pressure, closed center* K for position dual pressure, open center* L for single operator, single pressure with memory spring N for single operator, dual pressure with memory spring* A standard pilot exhaust C pilot exhaust to main valve exhaust** Body electrical 9B-XXA-XXX-XX-DXXP-XXX A no light B light(s) F suppression and blocking diode with light(s) H M.O.V. with light(s) Port configuration : Individual sub-base 9B-XXX-XAX-XX-DXXP-XXX Individual & Manifold sub-base Int. pilot 9B-XXX-XXA-XX-DXXP-XXX A side ports B bottom ports (1/8" only) C side & bottom ports (1/8" only) D side inlet & exhaust with bottom cylinder ports (1/8") A internal pilot no light B internal pilot single light C internal pilot double light Manifold sub-base 9B-XXX-XJX-XX-DXXP-XXX J side ports K bottom ports Individual sub-base Ext. pilot 9B-XXX-XXD-XX-DXXP-XXX D external pilot no light E external pilot single light F external pilot double light Pilot style : 9B-XXX-XXX-DM-DXXP-XXX 9B-XXX-XXX-DM-DXXP-XXX DM pilot exhaust muffled DP pilot exhaust piped (#10-) DU pilot exhaust to main exhaust Lead Wire Lengths : (manifold sub-base only) P 1 leads 1 18 leads 4 leads 6 leads 4 48 leads 5 7 leads Base only : 9B-000-XXX (i.e. 9B-000-AAA) - Individual base (Note: bases are wired for double solenoid valves) * Requires sandwich regulator. ** Must use DU pilot. Main valve exhaust cannot be restricted. 9B-000-XXX (i.e. 9B-000-BJA) - Manifold base 156 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Individual mounting Series Inline Sub-base non plug-in Sub-base plug-in Manifold mounting Sub-base non plug-in Sub-base plug-in 4 6 Bonded spool Air return Light option Manual operator Solenoid 4-way pilot with balanced poppet 7 8 5 67 69 44 46 EB B P A EA SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Optional memory spring. Plug-in design of valves and bases for ease of maintenance. position or position valve configurations. COND. 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 157 Consult Precautions page 7 before use, installation or service of MAC Valves..

EXH. B IN. A EXH. IN B EXH. A IN 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 SPOOL CONFIGURATIONS B A B A EXH B IN A EXH POSITION SINGLE PRESSURE SHOWN WITH "B" OPERATOR ENERGIZED IN B EXH A IN POSITION DUAL PRESSURE SHOWN WITH "B" OPERATOR ENERGIZED B A B A EXH B IN A EXH EXH B IN A EXH POSITION CLOSED CENTER SPRING CENTERING POSITION OPEN CENTER B A IN B EXH A IN REGULATOR CONFIGURATIONS SINGLE REGULATOR - SINGLE PRESSURE Pressure supplied to the individual or manifold base passes through the regulator. Regulated pressure is supplied to the pressure path of the valve. POSITION DUAL PRESSURE, PRESSURE CENTER DUAL REGULATOR - DUAL PRESSURE Pressure supplied from each regulator is divided in the block. Regulated pressure from A regulator supplies cylinder port A. Regulated pressure from B regulator supplies cylinder port B. Dual pressure regulators require dual pressure spool in valve. MANIFOLD WITH REGULATOR - SINGLE PRESSURE Note: For both single and dual pressure, air supply to the pilot system is never regulated. MANIFOLD WITH REGULATOR - DUAL PRESSURE 158 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Individual mounting Series 5/, 5/ /8-1/.8 C v Inline OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. Air only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 1 4 14 5/ Double operator 1 4 14 5/ Closed center 1 4 14 5/ Open center 1 4 14 4 6 7 8 5 67 69 44 46 /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF Internal External DUAL PRESSURE MODELS 1 5 9A-AJ0-B0J-DM-DXXX-XXX 9A-AJ0-C0J-DM-DXXX-XXX 9A-AJ0-B0K-DM-DXXX-XXX 9A-AJ0-C0K-DM-DXXX-XXX 1 5 9A-BJ0-B0J-DM-DXXX-XXX 9A-BJ0-C0J-DM-DXXX-XXX 9A-BJ0-B0K-DM-DXXX-XXX 9A-BJ0-C0K-DM-DXXX-XXX 1 5 9A-EJ0-B0J-DM-DXXX-XXX 9A-EJ0-C0J-DM-DXXX-XXX 9A-EJ0-B0K-DM-DXXX-XXX 9A-EJ0-C0K-DM-DXXX-XXX 1 5 9A-FJ0-B0J-DM-DXXX-XXX 9A-FJ0-C0J-DM-DXXX-XXX 9A-FJ0-B0K-DM-DXXX-XXX 9A-FJ0-C0K-DM-DXXX-XXX 4 47 48P Port size Pilot air 5/ Single operator 1 4 14 5/ Double operator 1 4 14 5/ Pressure center 1 4 14 48 /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF SOLENOID OPERATOR DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 B 4 (Flying leads) Locking recessed KD JC 4/50, 4/60 J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) BA DF 4 VDC (1.7W) * Other options available, see page 09. OPTIONS Internal External Pilot exhaust : 9A-XJX-XXX-DM-DXXX-XXX 1 5 J Standard pilot exhaust K Pilot exhaust to main exhaust (use DU pilot) 9A-CJ0-B0J-DM-DXXX-XXX 9A-CJ0-C0J-DM-DXXX-XXX 9A-CJ0-B0K-DM-DXXX-XXX 9A-CJ0-C0K-DM-DXXX-XXX 1 5 9A-DJ0-B0J-DM-DXXX-XXX 9A-DJ0-C0J-DM-DXXX-XXX 9A-DJ0-B0K-DM-DXXX-XXX 9A-DJ0-C0K-DM-DXXX-XXX 1 5 9A-HJ0-B0J-DM-DXXX-XXX 9A-HJ0-C0J-DM-DXXX-XXX 9A-HJ0-B0K-DM-DXXX-XXX 9A-HJ0-C0K-DM-DXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO Other options available for the 9 series valves, see page 169. 159 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot: 0 to 10 PSI External Pilot: Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).8 C v Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1.8 to 1.7 W Energize : 1 ms De-energize : 10 ms Option : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 4.4 5.1 WIXOM,MI.USA LIEGE,BELGIUM MODEL AUCKLAND,N.Z. MODIF. ELECTRICAL WATTS 40. VAC TO 10 PSI 6.9 16.1 Ø 6.0 () 1 14 EP 4 P 155.8 184. SINGLE SOLENOID DOUBLE SOLENOID 160 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/4 - /8-1/.4 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. Air only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS (1/4" MODELS ARE BOTTOM PORTED) Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 4 6 7 8 5 67 69 44 46 Valve less base 1/4 NPTF /8 NPTF 1/ NPTF 1/4 NPTF /8 NPTF 1/ NPTF Internal External SOLENOID OPERATOR 9A-ABA-000-DM-DXXX-XXX 9A-ABA-ABG-DM-DXXX-XXX 9A-ABA-BAG-DM-DXXX-XXX 9A-ABA-CAG-DM-DXXX-XXX 9A-ABA-ABH-DM-DXXX-XXX 9A-ABA-BAH-DM-DXXX-XXX 9A-ABA-CAH-DM-DXXX-XXX 9A-BBA-000-DM-DXXX-XXX 9A-BBA-ABG-DM-DXXX-XXX 9A-BBA-BAG-DM-DXXX-XXX 9A-BBA-CAG-DM-DXXX-XXX 9A-BBA-ABH-DM-DXXX-XXX 9A-BBA-BAH-DM-DXXX-XXX 9A-BBA-CAH-DM-DXXX-XXX DM-D XXX-XXX * 9A-EBA-000-DM-DXXX-XXX 9A-EBA-ABG-DM-DXXX-XXX 9A-EBA-BAG-DM-DXXX-XXX 9A-EBA-CAG-DM-DXXX-XXX 9A-EBA-ABH-DM-DXXX-XXX 9A-EBA-BAH-DM-DXXX-XXX 9A-EBA-CAH-DM-DXXX-XXX 9A-FBA-000-DM-DXXX-XXX 9A-FBA-ABG-DM-DXXX-XXX 9A-FBA-BAG-DM-DXXX-XXX 9A-FBA-CAG-DM-DXXX-XXX 9A-FBA-ABH-DM-DXXX-XXX 9A-FBA-BAH-DM-DXXX-XXX 9A-FBA-CAH-DM-DXXX-XXX DUAL PRESSURE MODELS REQUIRE SANDWICH REGULATOR, SEE REGULATORS SECTION (1/4" MODELS ARE BOTTOM PORTED) Port size Valve less base 1/4 NPTF /8 NPTF 1/ NPTF 1/4 NPTF /8 NPTF 1/ NPTF Pilot air Internal External 5/ Single operator 9A-CBA-000-DM-DXXX-XXX 9A-CBA-ABG-DM-DXXX-XXX 9A-CBA-BAG-DM-DXXX-XXX 9A-CBA-CAG-DM-DXXX-XXX 9A-CBA-ABH-DM-DXXX-XXX 9A-CBA-BAH-DM-DXXX-XXX 9A-CBA-CAH-DM-DXXX-XXX 5/ Double operator 9A-DBA-000-DM-DXXX-XXX 9A-DBA-ABG-DM-DXXX-XXX 9A-DBA-BAG-DM-DXXX-XXX 9A-DBA-CAG-DM-DXXX-XXX 9A-DBA-ABH-DM-DXXX-XXX 9A-DBA-BAH-DM-DXXX-XXX 9A-DBA-CAH-DM-DXXX-XXX 5/ Pressure center B B A EB IN EA 9A-HBA-000-DM-DXXX-XXX 9A-HBA-ABG-DM-DXXX-XXX 9A-HBA-BAG-DM-DXXX-XXX 9A-HBA-CAG-DM-DXXX-XXX 9A-HBA-ABH-DM-DXXX-XXX 9A-HBA-BAH-DM-DXXX-XXX 9A-HBA-CAH-DM-DXXX-XXX A 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed BM JB 0/50, 40/60 B 4 (Flying leads) Locking recessed BN JC 4/50, 4/60 J Connector BP FB 4 VDC (1.8W) BG DA 4 VDC (5.4W) JB DF 4 VDC (1.7W) JD * Other options available, see page 09. Other options available for the 9 series valves, see page 169. Electrical connection Flying leads Flying leads with diode Flying leads with M.O.V. Flying leads with ground Rectangular connector Rectangular connector with light 161 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot: 0 to 10 PSI External Pilot: Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/4, /8 : (.0 C v ) - 1/ : (.4 C v ) Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize : 1 ms De-energize : 10 ms Options : Spare parts : BSPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC9A-BA (screwdriver slot adjustment) FC9A-BB (locking knob adjustment) Pilot valve: DM-Dxxx-xxx Valve to base pressure seal: 166 Pilot valve pressure seal: 1654 Mounting screws valve to base (x4): 549 Pilot valve mounting screws (x): 5069 DIMENSIONS Dimensions shown are metric (mm) 185.4 DOUBLE SOLENOID 156.9 SINGLE SOLENOID 80.0 1/8" -7 NPTF EXTERNAL PILOT PORT 6.00 5.0 OPTIONAL BOTTOM PORTS /8" AND 1/4" ONLY 111.6 EP 1.65 6.0 A B IN EX CONDUIT 0.0 M L K J B IN A EX.00 46.00 5.85 1.0 E 9.1 57.0 8.5 H F 1/" -14 N.P.S.M. CONDUIT PORT 71.7 96.0 5. DIA MTG. HOLES G C D CYL. B CYL. A DIM. A B C D E F G H DIM. J K L M /8" 1/" 7.15 5.5 0.65 19.0 7.15 5.5 4.15.5 54.1 45.8 81.7 75. 8. 8. 7.5 7.5 1/4" /8" 7.0 8.5 14.7 16. 15.0 16.5 16.5 17.5 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Individual mounting Series 5/, 5/ 1/4 - /8-1/.4 C v Sub-base plug-in OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. Air only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS (1/4" MODELS ARE BOTTOM PORTED) Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 4 6 7 8 5 67 69 44 46 Valve less base 1/4 NPTF /8 NPTF 1/ NPTF 1/4 NPTF /8 NPTF 1/ NPTF Port size Valve less base 1/4 NPTF /8 NPTF 1/ NPTF 1/4 NPTF /8 NPTF 1/ NPTF Internal External 9A-AAA-000-DM-DXXP-XXX 9A-AAA-ABA-DM-DXXP-XXX 9A-AAA-BAA-DM-DXXP-XXX 9A-AAA-CAA-DM-DXXP-XXX 9A-AAA-ABD-DM-DXXP-XXX 9A-AAA-BAD-DM-DXXP-XXX 9A-AAA-CAD-DM-DXXP-XXX Pilot air Internal External 9A-BAA-000-DM-DXXP-XXX 9A-BAA-ABA-DM-DXXP-XXX 9A-BAA-BAA-DM-DXXP-XXX 9A-BAA-CAA-DM-DXXP-XXX 9A-BAA-ABD-DM-DXXP-XXX 9A-BAA-BAD-DM-DXXP-XXX 9A-BAA-CAD-DM-DXXP-XXX 5/ Single operator 9A-CAA-000-DM-DXXP-XXX 9A-CAA-ABA-DM-DXXP-XXX 9A-CAA-BAA-DM-DXXP-XXX 9A-CAA-CAA-DM-DXXP-XXX 9A-CAA-ABD-DM-DXXP-XXX 9A-CAA-BAD-DM-DXXP-XXX 9A-CAA-CAD-DM-DXXP-XXX 9A-EAA-000-DM-DXXP-XXX 9A-EAA-ABA-DM-DXXP-XXX 9A-EAA-BAA-DM-DXXP-XXX 9A-EAA-CAA-DM-DXXP-XXX 9A-EAA-ABD-DM-DXXP-XXX 9A-EAA-BAD-DM-DXXP-XXX 9A-EAA-CAD-DM-DXXP-XXX 5/ Double operator 9A-DAA-000-DM-DXXP-XXX 9A-DAA-ABA-DM-DXXP-XXX 9A-DAA-BAA-DM-DXXP-XXX 9A-DAA-CAA-DM-DXXP-XXX 9A-DAA-ABD-DM-DXXP-XXX 9A-DAA-BAD-DM-DXXP-XXX 9A-DAA-CAD-DM-DXXP-XXX 9A-FAA-000-DM-DXXP-XXX 9A-FAA-ABA-DM-DXXP-XXX 9A-FAA-BAA-DM-DXXP-XXX 9A-FAA-CAA-DM-DXXP-XXX 9A-FAA-ABD-DM-DXXP-XXX 9A-FAA-BAD-DM-DXXP-XXX 9A-FAA-CAD-DM-DXXP-XXX DUAL PRESSURE MODELS REQUIRE SANDWICH REGULATOR, SEE REGULATORS SECTION (1/4" MODELS ARE BOTTOM PORTED) SOLENOID OPERATOR DM-D XX P-XXX * 5/ Pressure Center B B A EB IN EA 9A-HAA-000-DM-DXXP-XXX 9A-HAA-ABA-DM-DXXP-XXX 9A-HAA-BAA-DM-DXXP-XXX 9A-HAA-CAA-DM-DXXP-XXX 9A-HAA-ABD-DM-DXXP-XXX 9A-HAA-BAD-DM-DXXP-XXX 9A-HAA-CAD-DM-DXXP-XXX Above models are shown without light. A 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO XX Voltage X Manual operator XX JA JB JC FB DA DF 110/50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/50, 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) 1 Non-locking recessed Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground * Other options available, see page 09. Note: Ground required for 0 Volts or higher. Other options available for the 9 series valves, see page 170. 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot: 0 to 10 PSI External Pilot: Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/4, /8 : (.0 C v ) - 1/ : (.4 C v ) Class A continuous duty, # AWG x 18 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize : 1 ms De-energize : 10 ms Options : Spare parts : BSPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC9A-AA (screwdriver slot adjustment) FC9A-AB (locking knob adjustment) Pilot valve: DM-DxxP-xxx Valve to base pressure seal: 166 Pilot valve pressure seal: 1654 Mounting screws valve to base (x4): 549 Pilot valve mounting screws (x): 5069 DIMENSIONS Dimensions shown are metric (mm) 185.4 DOUBLE SOLENOID 156.9 SINGLE SOLENOID 80.0 1/8" -7 NPTF EXTERNAL PILOT PORT 6.00 5.0 OPTIONAL BOTTOM PORTS /8" AND 1/4" ONLY 111.6 EP 1.65 6.0 A B IN EX CONDUIT 0.0 M L K J B IN A EX.00 46.00 5.85 1.0 E 9.1 57.0 8.5 H F 1/" -14 N.P.S.M. CONDUIT PORT 71.7 96.0 5. DIA MTG. HOLES G C D CYL. B CYL. A DIM. A B C D E F G H DIM. J K L M /8" 1/" 7.15 5.5 0.65 19.0 7.15 5.5 4.15.5 54.1 45.8 81.7 75. 8. 8. 7.5 7.5 1/4" /8" 7.0 8.5 14.7 16. 15.0 16.5 16.5 17.5 164 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ /8-1/.8 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. Air only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 4 6 7 8 5 67 69 44 46 Valve less base /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF Internal External SOLENOID OPERATOR 9A-ABA-000-DM-DXXX-XXX 9A-ABA-BJG-DM-DXXX-XXX 9A-ABA-CJG-DM-DXXX-XXX 9A-ABA-BJH-DM-DXXX-XXX 9A-ABA-CJH-DM-DXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed BM JB 0/50, 40/60 B 4 (Flying leads) Locking recessed BN JC 4/50, 4/60 J Connector KA FB 4 VDC (1.8W) KD DA 4 VDC (5.4W) DF 4 VDC (1.7W) * Other options available, see page 09. End plate kit required (1/ ports): M-9001-01-01 internal pilot. M-9001-0-01 external pilot. Other options available for the 9 series valves, see page 169. 9A-BBA-000-DM-DXXX-XXX 9A-BBA-BJG-DM-DXXX-XXX 9A-BBA-CJG-DM-DXXX-XXX 9A-BBA-BJH-DM-DXXX-XXX 9A-BBA-CJH-DM-DXXX-XXX 9A-EBA-000-DM-DXXX-XXX 9A-EBA-BJG-DM-DXXX-XXX 9A-EBA-CJG-DM-DXXX-XXX 9A-EBA-BJH-DM-DXXX-XXX 9A-EBA-CJH-DM-DXXX-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR, SEE REGULATORS SECTION) Port size Valve less base /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF Pilot air Internal External 5/ Single operator 9A-CBA-000-DM-DXXX-XXX 9A-CBA-BJG-DM-DXXX-XXX 9A-CBA-CJG-DM-DXXX-XXX 9A-CBA-BJH-DM-DXXX-XXX 9A-CBA-CJH-DM-DXXX-XXX 5/ Double operator 9A-DBA-000-DM-DXXX-XXX 9A-DBA-BJG-DM-DXXX-XXX 9A-DBA-CJG-DM-DXXX-XXX 9A-DBA-BJH-DM-DXXX-XXX 9A-DBA-CJH-DM-DXXX-XXX 9A-FBA-000-DM-DXXX-XXX 9A-FBA-BJG-DM-DXXX-XXX 9A-FBA-CJG-DM-DXXX-XXX 9A-FBA-BJH-DM-DXXX-XXX 9A-FBA-CJH-DM-DXXX-XXX 5/ Pressure center B B A EB IN EA 9A-HBA-000-DM-DXXX-XXX 9A-HBA-BJG-DM-DXXX-XXX 9A-HBA-CJG-DM-DXXX-XXX 9A-HBA-BJH-DM-DXXX-XXX 9A-HBA-CJH-DM-DXXX-XXX Above models are shown with side ports. Electrical connection Flying leads Flying leads with diode Square connector Square connector with light A 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO 165 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot: 0 to 10 PSI External Pilot: Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8 : (.4 C v ) - 1/ : (.8 C v ) Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize : 1 ms De-energize : 10 ms Options : Spare parts : BSPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC9A-BA (screwdriver slot adjustment), FC9A-BB (locking knob adjustment) Pilot valve: DM-Dxxx-xxx Valve to base pressure seal: 166 Pilot valve pressure seal: 1654 Mounting screws valve to base (x4): 549 Inlet/exh. Isolator disc: N-9008 Valve blanking plate: M-900 DIMENSIONS Dimensions shown are metric (mm) DOUBLE SOLENOID 0.7 1/8" N.P.T.F. PILOT PORT PLACES SINGLE SOLENOID 18.8 10.55 1.5 87.50 6. DIA 4 MTG. HOLES 19.05 B B 14.6.5 19.05.0 A EP A EP 15.0 A 57.0 5.5.0 EP 7.0 EB IN EA EX CONDUIT 7.5 19.05.5 A A B 11.5 9.0 70.0 105.0 14.6 1/" NPTF HOLES BOTH ENDS 10.55 64.70.80 OPTIONAL BOTTOM PORTS /8" & 1/" # 1 4 5 6 7 8 9 10 DIM. A B 71.6 105.1 18.6 17.1 05.6 9.1 7.6 06.1 9.6 7.1 /8" 1/" 47.66 49. 166 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 Function Port size Flow (Max) Manifold mounting Series 5/, 5/ /8-1/.8 C v Sub-base plug-in OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burn-out proof solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. Air only return. Optional memory spring is also available. 4. Optional low wattage DC solenoid down to 1 watt. 5. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 4 6 7 8 5 67 69 44 46 Valve less base /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF Internal External 9A-AAA-000-DM-DXXP-XXX 9A-AAA-BJA-DM-DXXP-XXX 9A-AAA-CJA-DM-DXXP-XXX 9A-AAA-BJD-DM-DXXP-XXX 9A-AAA-CJD-DM-DXXP-XXX 9A-BAA-000-DM-DXXP-XXX 9A-BAA-BJA-DM-DXXP-XXX 9A-BAA-CJA-DM-DXXP-XXX 9A-BAA-BJD-DM-DXXP-XXX 9A-BAA-CJD-DM-DXXP-XXX 5/ Single operator 9A-CAA-000-DM-DXXP-XXX 9A-CAA-BJA-DM-DXXP-XXX 9A-CAA-CJA-DM-DXXP-XXX 9A-CAA-BJD-DM-DXXP-XXX 9A-CAA-CJD-DM-DXXP-XXX 9A-EAA-000-DM-DXXP-XXX 9A-EAA-BJA-DM-DXXP-XXX 9A-EAA-CJA-DM-DXXP-XXX 9A-EAA-BJD-DM-DXXP-XXX 9A-EAA-CJD-DM-DXXP-XXX DUAL PRESSURE MODELS (REQUIRE SANDWICH REGULATOR, SEE REGULATORS SECTION) Port size Valve less base /8 NPTF 1/ NPTF /8 NPTF 1/ NPTF SOLENOID OPERATOR Pilot air Internal External 5/ Double operator 9A-DAA-000-DM-DXXP-XXX 9A-DAA-BJA-DM-DXXP-XXX 9A-DAA-CJA-DM-DXXP-XXX 9A-DAA-BJD-DM-DXXP-XXX 9A-DAA-CJD-DM-DXXP-XXX XX Voltage X Manual operator XX JA JB JC FB DA DF 110/50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/50, 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) DM-D XX P-XXX * 1 Non-locking recessed Locking recessed 9A-FAA-000-DM-DXXP-XXX 9A-FAA-BJA-DM-DXXP-XXX 9A-FAA-CJA-DM-DXXP-XXX 9A-FAA-BJD-DM-DXXP-XXX 9A-FAA-CJD-DM-DXXP-XXX 5/ Pressure Center B B A EB IN EA 9A-HAA-000-DM-DXXP-XXX 9A-HAA-BJA-DM-DXXP-XXX 9A-HAA-CJA-DM-DXXP-XXX 9A-HAA-BJD-DM-DXXP-XXX 9A-HAA-CJD-DM-DXXP-XXX Above model numbers are shown with side ports without light. DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground A 4 47 48P 48 400 9 9 ISO 01 ISO 0 ISO 1 ISO ISO * Other options available, see page 09. End plate required (1/ ports): M-9001-01-01 Internal pilot. M-9001-0-01 External pilot. Other options available for the 9 series valves, see page 170. 167 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 9 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5.4 W coil) Compressed air, vacuum, inert gases Internal Pilot: 0 to 10 PSI External Pilot: Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8 : (.4 C v ) - 1/ : (.8 C v ) Class A continuous duty, # AWG x 18 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize : 1 ms De-energize : 10 ms Options : Spare parts : BSPP thread Sandwich regulator (see regulators section) Sandwich flow controls FC9A-AA (screwdriver slot adjustment), FC9A-AB (locking knob adjustment) Pilot valve: DM-DxxP-xxx Valve to base pressure seal: 166 Pilot valve pressure seal: 1654 Mounting screws valve to base (x4): 549 Inlet/exh. Isolator disc: N-9008 Valve blanking plate: M-900 DIMENSIONS Dimensions shown are metric (mm) DOUBLE SOLENOID 0.7 1/8" N.P.T.F. PILOT PORT PLACES SINGLE SOLENOID 18.8 10.55 1.5 87.50 6. DIA 4 MTG. HOLES 19.05 B B 141.6.5 19.05.0 A EP A EP 15.0 A 57.0 5.5.0 7.0 EP EB IN EX EA CONDUIT 7.5 19.05.5 A A B 11.5 9.0 70.0 105.0 14.6 1/" NPTF HOLES BOTH ENDS 10.55 64.70.80 OPTIONAL BOTTOM PORTS /8" & 1/" # 1 4 5 6 7 8 9 10 DIM. A B 71.6 105.1 18.6 17.1 05.6 9.1 7.6 06.1 9.6 7.1 /8" 1/" 47.66 49. 168 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 9 OPTIONS FOR NON PLUG-IN AND INLINE VALVES Valve function 9A-LXX-XXX-XX-DXXX-XXX Pilot exhaust 9A-XBX-XXX-XX-DXXX-XXX L for single operator, single pressure with memory spring N for single operator, dual pressure with memory spring R for single operator universal spool (ext. pilot only) S for double operator universal spool (ext. pilot only) B standard pilot exhaust D pilot exhaust to main valve exhaust* Port configuration : Individual sub-base 9A-XXX-XAX-XX-DXXX-XXX Manifold sub-base 9A-XXX-XJX-XX-DXXX-XXX 4 6 7 8 5 67 69 44 46 Pilot style : A side ports (/8 & 1/" only) B bottom ports (1/4 & /8" only) C side & bottom ports (1/4" & /8 only) D side inlet & exhaust with bottom cylinder ports (1/4" & /8 only) J side ports K bottom ports 4 47 48P 9A-XXX-XXX-DM-DXXX-XXX DM pilot exhaust muffled DP pilot exhaust piped (#10-) DU pilot exhaust to main exhaust 48 Base only : 9A-000-XXX (i.e. 9A-000-BAG) - Individual base 9A-000-XXX (i.e. 9A-000-BJG) - Manifold base 400 9 * Must use DU pilot. Main valve exhaust cannot be restricted. 9 ISO 01 ISO 0 ISO 1 ISO ISO 169 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot oper Series 9 OPTIONS FOR PLUG-IN VALVES Valve function 9A- LXX-XXX-XX-D XX P-XXX L N R S for single operator, single pressure with memory spring for single operator, dual pressure with memory spring for single operator universal spool (ext. pilot only) for double operator universal spool (ext. pilot only) Pilot exhaust 9A-X A X-XXX-XX-D XX P-XXX A C standard pilot exhaust pilot exhaust to main valve exhaust* Body electrical 9A-XXA -XXX-XX-D XX P-XXX A no light B light(s) Port configuration : Individual sub-base 9A-XXX-X A X-XX-DXX P-XXX Manifold sub-base 9A-XXX-X J X-XX-DXX P-XXX Base/manifold int./ext. pilot 9A-XXX-XX A -XX-DXX P-XXX Pilot style : 9A-XXX-XXX- DM -DXX P-XXX A side ports (/8 & 1/" only) B bottom ports (1/4 & /8" only) C side & bottom ports (1/4" & /8 only) D side inlet & exhaust with bottom cylinder ports (1/4" & /8 only) A internal pilot no light B internal pilot single light C internal pilot double light D external pilot no light E external pilot single light F external pilot double light DM pilot exhaust muffled DP pilot exhaust piped (#10-) DU pilot exhaust to main exhaust J K side ports bottom ports Base only : 9A-000-XXX (i.e. 9A-000-BAA) - Individual base (Note: bases are wired for double solenoid valves) * Must use DU pilot. Main valve exhaust cannot be restricted. 9A-000-XXX (i.e. 9A-000-BJA) - Manifold base 170 Consult Precautions page 7 before use, installation or service of MAC Va

Direct solenoid and solenoid pilot operated valves Series ISO 01 SIZE 6 mm Individual mounting Valve only No base non plug-in Conform to ISO 15407/1 Manifold mounting Valve only No base non plug-in Conform to ISO 15407/1 Solenoid Integral 4-way pilot valve Series 4 6 7 8 5 67 69 44 46 4 Manual operator 47 48P Bonded spool Air return 48 400 9 SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. -position, single or double operator. -position, double solenoid, open center, closed center and pressure center. Internal or external pilot. Single or dual pressure. 9 ISO 01 ISO 0 ISO 1 ISO ISO 171 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 01 SIZE 6 mm Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/4 1.0 C v No base non plug-in Valve only Conform to ISO 15407/1 OPERATIONAL BENEFITS 1. Unique patented MACsolenoid with oval shaped armature for fastest possible response times.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. Pilot valve and main valve in the same body. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end External "14" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-A01A-AAMA-JXXX-XXX MV-A01A-AAMD-JXXX-XXX MV-A01A-AAME-JXXX-XXX 6. Internal or external pilot operation. 7. Air only return 8. Optional low wattage DC solenoid down to 1.0 Watt. 5/ Double operator 14 4 1 5 1 MV-A01A-ABMA-JXXX-XXX MV-A01A-ABMD-JXXX-XXX MV-A01A-ABME-JXXX-XXX 5/ Single operator 14 4 1 5/ Closed center 14 4 1 5 1 MV-A01A-AEMA-JXXX-XXX MV-A01A-AEMD-JXXX-XXX MV-A01A-AEME-JXXX-XXX 5/ Double operator 14 4 1 5/ Open center 14 4 1 5 1 MV-A01A-AFMA-JXXX-XXX MV-A01A-AFMD-JXXX-XXX MV-A01A-AFME-JXXX-XXX 5/ Pressure center 14 1 4 6 7 8 5 67 69 44 46 4 47 48P 48 Internal from port # Internal from port #5 5 1 MV-A01A-ACMB-JXXX-XXX MV-A01A-ACMC-JXXX-XXX 5 1 MV-A01A-ADMB-JXXX-XXX MV-A01A-ADMC-JXXX-XXX 5 1 MV-A01A-AHMB-JXXX-XXX MV-A01A-AHMC-JXXX-XXX 400 External from "1" end External from "14" end MV-A01A-ACMD-JXXX-XXX MV-A01A-ACME-JXXX-XXX MV-A01A-ADMD-JXXX-XXX MV-A01A-ADME-JXXX-XXX MV-A01A-AHMD-JXXX-XXX MV-A01A-AHME-JXXX-XXX 9 SOLENOID OPERATOR J XXX-XXX * XX Voltage X Lead wire length X Manual operator XX DA DB DC DD DE DU 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) 4 VDC (1.8W) 4 VDC (1.0W) 0 No lead wire/ connector A 18 B 4 C 6 1 Non-locking Locking * Other options available, see page 17. Note: - ISO series, valve and base are ordered separately, see page 7 for base codes. - If sandwich regulator is required, valve must be ordered as external pilot. For internal pilot regulator use valve with external pilot 1 end, - for external pilot regulator, use valve with external pilot 1 or 14 end. BA JA JC JB JD KA KD Electrical connection Flying leads Square connector Square connector with light Rectangular connector Rectangular connector with light Mini square connector Mini square connector with light 9 ISO 01 ISO 0 ISO 1 ISO ISO OPTIONS Pilot exhaust: MV-A01A-XX X X-JXXX-XXX M Pilot exhaust muffled P Pilot exhaust piped #10- U Pilot exhaust out main exhaust 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 01 SIZE 6 mm TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases Internal Pilot - pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External Pilot: Vacuum to 10 PSI pos.: 0 to 10 PSI - pos.: 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) pos.: Cv 1.0 pos.: Cv 0.8 Class A wires continuous duty, # AWG x 18-15% to +10% of nominal voltage 1,0 to 5,4 W Options : Sandwich flow controls: FCA01A-AA (screwdriver slot adjustment). Sandwich pressure regulator, see Regulators section DIMENSIONS Individual base 158.8 Dimensions shown are metric (mm) Manifold base 5.4 7.0 19.0 0.5 47.0 49.4 55.0 110.9 1/8" 1 & 14 9.50 4.5 11.8 9.1 1.7 18.5.85 17. 11. 7.5 49.9 160.1 11.0 16.9 8.1 6.1 66.8 Ø 6.5 1/8" 1 & 14 /8" 1, &5 1/8" 1 & 14 9.5 4.0 47.5 1/4" SHOWN 9.5 19.5 174 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 0 SIZE 18 mm Individual mounting Valve only No base non plug-in Conform to ISO 15407/1 Manifold mounting Valve only No base non plug-in Conform to ISO 15407/1 Solenoid Integral 4-way pilot valve Series 4 6 7 8 5 67 69 44 46 4 Manual operator 47 48P Bonded spool Air return 48 400 9 SERIES FEATURES High force MACSOLENOID. Integral 4-way pilot design. -position, single or double operator. -position, double solenoid, open center, closed center and pressure center. Internal or external pilot. Single or dual pressure. 9 ISO 01 ISO 0 ISO 1 ISO ISO 175 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 0 SIZE 18 mm Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/8 0.4 C v No base non plug-in Valve only Conform to ISO 15407/1 OPERATIONAL BENEFITS 1. Unique patented MACsolenoid with oval shaped armature for fastest possible response times.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. Pilot valve and main valve in the same body. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end External "14" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-A0A-AAMA-JXXX-XXX MV-A0A-AAMD-JXXX-XXX MV-A0A-AAME-JXXX-XXX 6. Internal or external pilot operation. 7. Air only return 8. Optional low wattage DC solenoid down to 1.0 Watt. 5/ Double operator 14 4 1 5 1 MV-A0A-ABMA-JXXX-XXX MV-A0A-ABMD-JXXX-XXX MV-A0A-ABME-JXXX-XXX 5/ Single operator 14 4 1 5/ Closed center 14 4 1 5 1 MV-A0A-AEMA-JXXX-XXX MV-A0A-AEMD-JXXX-XXX MV-A0A-AEME-JXXX-XXX 5/ Double operator 14 4 1 5/ Open center 14 4 1 5 1 MV-A0A-AFMA-JXXX-XXX MV-A0A-AFMD-JXXX-XXX MV-A0A-AFME-JXXX-XXX 5/ Pressure center 14 1 4 6 7 8 5 67 69 44 46 4 47 48P 48 Internal from port # Internal from port #5 5 1 MV-A0A-ACMB-JXXX-XXX MV-A0A-ACMC-JXXX-XXX 5 1 MV-A0A-ADMB-JXXX-XXX MV-A0A-ADMC-JXXX-XXX 5 1 MV-A0A-AHMB-JXXX-XXX MV-A0A-AHMC-JXXX-XXX 400 External from "1" end External from "14" end MV-A0A-ACMD-JXXX-XXX MV-A0A-ACME-JXXX-XXX MV-A0A-ADMD-JXXX-XXX MV-A0A-ADME-JXXX-XXX MV-A0A-AHMD-JXXX-XXX MV-A0A-AHME-JXXX-XXX 9 SOLENOID OPERATOR J XXX-XXX * XX Voltage X Lead wire length X Manual operator XX DA DB DC DD DE DU 4V=/5,4W 1V=/5,4W 4V=/,4W 1V=/,4W 4V=/1,8W 4V=/1,0W 0 No lead wire/ connector A 45 cm B 60 cm C 90 cm 1 Non-locking Locking BA JA JC JB JD KA KD Electrical connection Flying leads Square connector Square connector with light Rectangular connector Rectangular connector with light Mini square connector Mini square connector with light * Other options available, see page 17. Note: - ISO series, valve and base are ordered separately, see page 9 for base codes. - If sandwich regulator is required, valve must be ordered as external pilot. For internal pilot regulator use valve with external pilot 1 end, - for external pilot regulator, use valve with external pilot 1 or 14 end. 9 ISO 01 ISO 0 ISO 1 ISO ISO OPTIONS Pilot exhaust: MV-A0A-XX X X-JXXX-XXX M Pilot exhaust muffled P Pilot exhaust piped #10- U Pilot exhaust out main exhaust 177 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 0 SIZE 18 mm TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases Internal Pilot - pos.: 0 to 10 PSI - pos.: 5 to 10 PSI External Pilot: Vacuum to 10 PSI pos.: 0 to 10 PSI - pos.: 5 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) pos.: Cv 0.4 pos.: Cv 0.8 Class A wires continuous duty, # AWG x 18-15% to +10% of nominal voltage 1,0 to 5,4 W Options : Sandwich flow controls: FCA0A-AA (screwdriver slot adjustment). Sandwich pressure regulator, see Regulators section DIMENSIONS Individual base Dimensions shown are metric (mm) Manifold base 11.4.7 19.0 9.5 5.4 40.4 4.0 50.0 104.6 1/8" 1 & 14 11.5 86.5 4.0 5.0 17.5 17.7 101.9 4.8 40.6 10.9 15.9.8 48. 54.8 144.0 1. Ø 5. (4) 1/8" 1 & 14 1/4" 1, & 5 PORTS 1/8" 1 & 14 7.8 7.6 4.5 1/8" 7.5 11.5 178 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 1 Individual mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Manifold mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Series 4 6 Bonded spool Balanced 4-way poppet Internal pilot supply Manual operator Large spool diameter External pilot supply 7 8 5 67 69 44 46 Air return 4 47 48P External pilot supply 1 4 5 48 400 9 SERIES FEATURES Plug-in (5599/) and non plug-in (5599/1) models. -position, single or double operator. (Solenoid or Remote Air) -position, double solenoid, open center, closed center, and pressure center. Extended or recessed manual operators. Single pressure and dual pressure. Individual base or add-a-unit manifold base. Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves. 9 ISO 01 ISO 0 ISO 1 ISO ISO 179 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 1 Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/4 - /8 1.8 C v No base non plug-in Valve only Conform to ISO 5599/1 OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-B1A-AAAA-DM-DXXX-XXX MV-B1A-AAAB-DM-DXXX-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator MV-B1A-ABAA-DM-DXXX-XXX MV-B1A-ABAB-DM-DXXX-XXX 5/ Single operator 14 4 1 5 1 5/ Closed center 14 4 1 5 1 MV-B1A-AEAA-DM-DXXX-XXX MV-B1A-AEAB-DM-DXXX-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-B1A-AFAA-DM-DXXX-XXX MV-B1A-AFAB-DM-DXXX-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-B1A-ACAD-DM-DXXX-XXX 14 4 1 5 1 MV-B1A-ADAD-DM-DXXX-XXX 14 1 5 MV-B1A-AGAD-DM-DXXX-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-B1A-ACAE-DM-DXXX-XXX MV-B1A-ACAB-DM-DXXX-XXX MV-B1A-ADAE-DM-DXXX-XXX MV-B1A-ADAB-DM-DXXX-XXX MV-B1A-AGAE-DM-DXXX-XXX MV-B1A-AGAB-DM-DXXX-XXX 400 SOLENOID OPERATOR DM-D XXX-XXX * 9 XX Voltage X Lead wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 B 4 (Flying leads) Locking recessed KD JC 4/50, 4/60 J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) BA DF 4 VDC (1.7W) * Other options available, see page 09. Note: ISO series, valve and base are ordered separately, see page 1 for base code. OPTIONS Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-B1A-AXXX-XX-DXXX-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-B1A-AXXX-DM-DXXX-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-B1A-AXAX-XX-DXXX-XXX A Standard return B Memory spring return 181 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5,4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8": (1.8 C v ) 1/4": (1.6 C v ) Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize :11. ms De-energize : 7.8 ms Options : Spare parts : Sandwich flow controls: FCP1A-BA (screwdriver slot adjustment) FCP1A-BB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-Dxxx-xxx Valve to base pressure seal: 16661 DIMENSIONS Individual base Manifold base Dimensions shown are metric (mm) DOUBLE SOLENOID 17.9 16.9 SINGLE SOLENOID 111. 1 16.7 14 1 /8" COMMONS P 5 15. 15.8. 5.8 5 1 16.0.7.5 41.0.5 45.5 1/" NPSM CONDUIT 57.5 67. 107.8 147.5 OPTIONAL COMMON EXTERNAL PILOT 10.5 86.5 4.5 60.5 OPTIONAL BOTTOM PORTS 105.5 69.5 45.5 1.5 Ø 6. TYP () 51.0 11.5 OPTIONAL BOTTOM PORT 60.5 9.5.5 6. DIA. THRU () MTG HOLES 6. 8.6 14 5 4 1 17.8 56. 45.7 16.0 1 4 50.0 7. 5 1 4 1.5 8.0 5. 5. 100. 57.5 77.4.5 1.6 5.5 1.5 10.0 115.5 86.5 15.5 56.5 18 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO 1 Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/4 - /8 1.8 C v No base plug-in Valve only Conform to ISO 5599/ OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-P1A-AAAA-DM-DXXP-XXX MV-P1A-AAAB-DM-DXXP-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator 14 4 1 5 1 MV-P1A-ABAA-DM-DXXP-XXX MV-P1A-ABAB-DM-DXXP-XXX 5/ Single operator 5/ Closed center 14 4 1 5 1 MV-P1A-AEAA-DM-DXXP-XXX MV-P1A-AEAB-DM-DXXP-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-P1A-AFAA-DM-DXXP-XXX MV-P1A-AFAB-DM-DXXP-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-P1A-ACAD-DM-DXXP-XXX 14 4 1 5 1 MV-P1A-ADAD-DM-DXXP-XXX 14 1 5 MV-P1A-AGAD-DM-DXXP-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-P1A-ACAE-DM-DXXP-XXX MV-P1A-ACAB-DM-DXXP-XXX MV-P1A-ADAE-DM-DXXP-XXX MV-P1A-ADAB-DM-DXXP-XXX MV-P1A-AGAE-DM-DXXP-XXX MV-P1A-AGAB-DM-DXXP-XXX 400 SOLENOID OPERATOR DM-D XX P-XXX * 9 XX Voltage X Manual operator XX JA JB JC FB DA DF 110/50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/50, 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) * Other options available, see page 09. Note: - ISO series, valve and base are ordered separately, see page for base codes. - Ground wire required for 0 volts or higher. OPTIONS 1 Non-locking recessed Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-P1A-AXXX-XX-DXXP-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-P1A-AXXX-DM-DXXP-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-P1A-AXAX-XX-DXXP-XXX A Standard return B Memory spring return D Standard return with light E Memory spring return with light 18 Consult Precautions page 7 before use, installation or service of MAC Valves..

4 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with 5,4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8": (1.8 C v ) 1/4": (1.6 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1 to 1.7 W Energize :10 ms De-energize : 9 ms Options : Spare parts : Sandwich flow controls: FCP1A-AA (screwdriver slot adjustment) FCP1A-AB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-DxxP-xxx Valve to base pressure seal: 16661 DIMENSIONS Individual base Dimensions shown are metric (mm) Manifold base 108.5 1" NPSM CONDUIT OPTIONAL COMMON EXTERNAL PILOT 1/8" 17.0 111. P 5 1 15. 15.8. 5.8 41.0. 6.9 6.0 COND 5 1 40.5 9.7 0.9. 16.0 1/" NPSM CONDUIT 107.8 147.5 67. 57.5 45.5.7.5 159. 90.7 9.0 115. 1.8 8.5 65.5 0. /8" COMMONS TYP() OPTIONAL BOTTOM PORTS 105.5 69.5 45.5 1.5 Ø 6. TYP () 15.5 8.0.0 5.0 5 90. 70.7 5.4 1.7 8.0 40.0 6. 8.6 5. 14 5 4 1.5 57.5 77.4 100. 17.8 56. 45.7 1.6 1.0 OPTIONAL BOTTOM PORTS 1 90.5 15.0 46. 5.0 15.0 1 15.9 4.0 Ø 6. THRU () MTG HOLES 4 4.0 1.0 184 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Manifold mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Series 4 6 Bonded spool Balanced 4-way poppet Internal pilot supply Manual operator Large spool diameter External pilot supply 7 8 5 67 69 44 46 Air return 4 47 48P External pilot supply 1 4 5 48 400 9 SERIES FEATURES Plug-in (5599/) and non plug-in (5599/1) models. -position, single or double operator. (Solenoid or Remote Air) -position, double solenoid, open center, closed center, and pressure center. Extended or recessed manual operators. Single pressure and dual pressure. Individual base or add-a-unit manifold base. Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves. 9 ISO 01 ISO 0 ISO 1 ISO ISO 185 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ /8-1/.0 C v No base non plug-in Valve only Conform to ISO 5599/1 OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-BA-AAAA-DM-DXXX-XXX MV-BA-AAAB-DM-DXXX-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator MV-BA-ABAA-DM-DXXX-XXX MV-BA-ABAB-DM-DXXX-XXX 5/ Single operator 14 4 1 5 1 5/ Closed center 14 4 1 5 1 MV-BA-AEAA-DM-DXXX-XXX MV-BA-AEAB-DM-DXXX-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-BA-AFAA-DM-DXXX-XXX MV-BA-AFAB-DM-DXXX-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-BA-ACAD-DM-DXXX-XXX 14 4 1 5 1 MV-BA-ADAD-DM-DXXX-XXX 14 1 5 MV-BA-AGAD-DM-DXXX-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-BA-ACAE-DM-DXXX-XXX MV-BA-ACAB-DM-DXXX-XXX MV-BA-ADAE-DM-DXXX-XXX MV-BA-ADAB-DM-DXXX-XXX MV-BA-AGAE-DM-DXXX-XXX MV-BA-AGAB-DM-DXXX-XXX 400 SOLENOID OPERATOR DM-D XXX-XXX * 9 XX Voltage X Lead wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 B 4 (Flying leads) Locking recessed KD JC 4/50, 4/60 J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) BA DF 4 VDC (1.7W) * Other options available, see page 09. Note: ISO series, valve and base are ordered separately, see page 5 for base code. OPTIONS Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-BA-AXXX-XX-DXXX-XXX Pilot style : MV-BA-AXXX-DM-DXXX-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-BA-AXAX-XX-DXXX-XXX A Standard return B Memory spring return 187 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8": (.8 C v ) - 1/": (.0 C v ) Class A continuous duty, # AWG x 18 leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1.7 to 1.0 W 4 VDC 5.4w Energize : 10 ms De-energize : 9.6 ms 10/60 Energize : 6-15 ms De-energize : 10-17 ms Options : Spare parts : Sandwich flow controls: FCPA-BA (screwdriver slot adjustment) FCPA-BB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-Dxxx-xxx Valve to base pressure seal: 16576 Valve mounting screws (x4): 541 DIMENSIONS Individual base 16.9 151.0 19.0 SINGLE & DOUBLE SOLENOID 16.9 18.0 18.9 10.5 Dimensions shown are metric (mm) Manifold base 1/8" EXT. PILOT 14.9 1/8 EXT. PILOT 14.9 50.5 4.0 0.0 9.0 54.0 8.0.0 6.0 5 4 1 4.0.0.0 14.5.0 0.0 6.0 6.0 4 70.0 70.0 104.0.0 4.0 1 OPTIONAL BTM. PORTS 5 1/" SIDE PORTS () EACH SIDE 7.0 9.0 0.5 5.0 64.0 1.0 5.5 68.5 47.5 40.0 56.0 7.0 56.0 5.0 5 87.0 86.0 1 4 1.5 6.0 5.5 6.5 DIA. MTG. HOLES 1.0 19.0 11.0 7.5 DIA. THRU MTG. HOLES 98.0 OPTIONAL BTM PORTS 8.0 74.0 100.0 188 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ /8-1/.0 C v No base plug-in Valve only Conform to ISO 5599/ OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-PA-AAAA-DM-DXXP-XXX MV-PA-AAAB-DM-DXXP-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator 14 4 1 5 1 MV-PA-ABAA-DM-DXXP-XXX MV-PA-ABAB-DM-DXXP-XXX 5/ Single operator 5/ Closed center 14 4 1 5 1 MV-PA-AEAA-DM-DXXP-XXX MV-PA-AEAB-DM-DXXP-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-PA-AFAA-DM-DXXP-XXX MV-PA-AFAB-DM-DXXP-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-PA-ACAD-DM-DXXP-XXX 14 4 1 5 1 MV-PA-ADAD-DM-DXXP-XXX 14 1 5 MV-PA-AGAD-DM-DXXP-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-PA-ACAE-DM-DXXP-XXX MV-PA-ACAB-DM-DXXP-XXX MV-PA-ADAE-DM-DXXP-XXX MV-PA-ADAB-DM-DXXP-XXX MV-PA-AGAE-DM-DXXP-XXX MV-PA-AGAB-DM-DXXP-XXX 400 SOLENOID OPERATOR DM-D XX P-XXX * 9 XX Voltage X Manual operator XX JA 110/50, 10/60 JB 0/50, 40/60 JC 4/50, 4/60 FB 4 VDC (1.8W) DA 4 VDC (5.4W) DF 4 VDC (1.7W) * Other options available, see page 09. Note: - ISO series, valve and base are ordered separately, see page 7 for base codes. - Ground wire required for 0 volts or higher. OPTIONS 1 Non-locking recessed Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-PA-AXXX-XX-DXXP-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-PA-AXXX-DM-DXXP-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-PA-AXAX-XX-DXXP-XXX A Standard return B Memory spring return D Standard return with light E Memory spring return with light 189 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) /8": (.8 C v ) - 1/": (.0 C v ) Class A continuous duty, #18 AWG x 1 base leads -15% to +10% of nominal voltage Consult factory ~ Inrush 14.8 VA Holding: 10.9 VA = 1.7 to 1.0 W 4 VDC 5.4w Energize : 10 ms De-energize : 9.6 ms 10/60 Energize : 6-15 ms De-energize : 10-17 ms Options : Spare parts : Sandwich flow controls: FCPA-AA (screwdriver slot adjustment) FCPA-AB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-DxxP-xxx Valve to base pressure seal: 16576 Valve mounting screws (x4): 541 DIMENSIONS Individual base 17.8 156.1 DOUBLE SOLENOID Manifold base 146.8 SINGLE SOLENOID 1/" N.P.S.M. CONDUIT 18. 105.5 187.0 SINGLE & DOUBLE SOLENOID 115.9 #14 EXTERNAL PILOT 1/8" OPTIONAL COMMON EXTERNAL PILOT 1/8" 1-1/4" N.P.S.M. CONDUIT 4 4.5 B C.0 A 4.0 4.5 #1 EXTERNAL PILOT 1/8" #14 EXTERNAL PILOT 1/8" 14.1 #1 EXTERNAL PILOT 1/8" 4.5 4.5 #1 40.0 70.0 1 D E 4 55.0 5 F G 140.0 15.0 6.5 DIA. THRU ()MTG HOLES 5.5 17.0.0 #14 48.5 54.50 65.5 50.0 9.5 41.5 8.0 7.0 CENT. OF 1/" SIDE CYL. 45.0 19.0 17.5 CENT. OF /8" SIDE CYL. 0.0 18.0 #1 15.0 1 11. 5.5 71.5 10.0 10.0 45.0.0 4 1 5 5 OPTIONAL BOTTOM PORTS COND 8.5 6.0 6.0 0.0 45.0 8.0 6.5 DIA. THRU ()MTG HOLES 18.5 #14 60.0 50.0 51.0 5.5 119.5 0.5 51.0 OPTIONAL BOTTOM PORTS 5.50 77.0 168.00 81.0 DIM. A B C D E F G /8" 1/" 5. 4.0.7 1.0 0.6 19.0 6.7 5.5 40.5 40.0 69.4 70.0 8. 84.5 190 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Manifold mounting Valve only No base non plug-in Conform to ISO 5599/1 Valve only No base plug-in Conform to ISO 5599/ Series 4 6 Bonded spool Balanced 4-way poppet Internal pilot supply Manual operator Large spool diameter External pilot supply 7 8 5 67 69 44 46 Air return 4 47 48P External pilot supply 1 4 5 48 400 9 SERIES FEATURES Plug-in (5599/) and non plug-in (5599/1) models. -position, single or double operator. (Solenoid or Remote Air) -position, double solenoid, open center, closed center, and pressure center. Extended or recessed manual operators. Single pressure and dual pressure. Individual base or add-a-unit manifold base. Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves. 9 ISO 01 ISO 0 ISO 1 ISO ISO 191 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/ - /4 6.1 C v No base non plug-in Valve only Conform to ISO 5599/1 OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-BA-AAAA-DM-DXXX-XXX MV-BA-AAAB-DM-DXXX-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator MV-BA-ABAA-DM-DXXX-XXX MV-BA-ABAB-DM-DXXX-XXX 5/ Single operator 14 4 1 5 1 5/ Closed center 14 4 1 5 1 MV-BA-AEAA-DM-DXXX-XXX MV-BA-AEAB-DM-DXXX-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-BA-AFAA-DM-DXXX-XXX MV-BA-AFAB-DM-DXXX-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-BA-ACAD-DM-DXXX-XXX 14 4 1 5 1 MV-BA-ADAD-DM-DXXX-XXX 14 1 5 MV-BA-AGAD-DM-DXXX-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-BA-ACAE-DM-DXXX-XXX MV-BA-ACAB-DM-DXXX-XXX MV-BA-ADAE-DM-DXXX-XXX MV-BA-ADAB-DM-DXXX-XXX MV-BA-AGAE-DM-DXXX-XXX MV-BA-AGAB-DM-DXXX-XXX 400 SOLENOID OPERATOR DM-D XXX-XXX * 9 XX Voltage X Lead wire length X Manual operator XX JA 110/50, 10/60 A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 B 4 (Flying leads) Locking recessed KD JC 4/50, 4/60 J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) BA DF 4 VDC (1.7W) * Other options available, see page 09. Note: ISO series, valve and base are ordered separately, see page 9 for base code. OPTIONS Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-BA-AXXX-XX-DXXX-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-BA-AXXX-DM-DXXX-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-BA-AXAX-XX-DXXX-XXX A Standard return B Memory spring return 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

4 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (5.4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/": (5.4 C v ) /4": (6.1 C v ) Class A continuous duty, # AWG leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1.7 to 1.0 W Energize : 16. ms De-energize : 1.6 ms Options : Sandwich regulator, see Regulators section Spare parts : Pilot valve: DMB-Dxxx-xxx Valve to base pressure seal: 16614 Valve mounting screws (x4): 5451 DIMENSIONS Individual base DOUBLE SOLENOID W/ 190.4 EXTENDED OVERRIDE SINGLE SOLENOID W/ 175.0 EXTENDED OVERRIDE 160.0 Dimensions shown are metric (mm) Manifold base 6.5 P.0 1 4 77,9 50.0 40.0 19.0 19.9 WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 10 PSI MODIF. 44.5.5 9.0 5 1 4 7.0.0 18.5 65.8 48.8.8 COND 5 1 160.8 6. 47.0 48.0 7.8 57.5 78.0 77.0 98.5 16.0 17.0 8. DIA. THRU 4 MTG. HOLES 96.0 140.0 16.0 175. 188.9.1 50. 17. 7.5 8.0 66.5 64.0 5 1 18.5 4.5 54.5.4 7.0 8.5 DIA. THRU MTG HOLES 16.4 99.9 5.8 19.0 9.0 4 OPTIONAL BTM PORTS 78.0 1.0 5 1 59.0 7.0 59.5 94.5 140.0 08.0 9.0 55.7 194 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/, 5/ 1/ - /4 6.1 C v No base plug-in Valve only Conform to ISO 5599/ OPERATIONAL BENEFITS 1. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet 4-way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service. 4. Large spool area for maximum shifting forces even at minimum operating pressure. 5. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "1" end DUAL PRESSURE MODELS Pilot air 5/ Single operator 14 4 1 5 1 MV-PA-AAAA-DM-DXXP-XXX MV-PA-AAAB-DM-DXXP-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to 1.0 watt. 5/ Double operator 14 4 1 5 1 MV-PA-ABAA-DM-DXXP-XXX MV-PA-ABAB-DM-DXXP-XXX 5/ Single operator 5/ Closed center 14 4 1 5 1 MV-PA-AEAA-DM-DXXP-XXX MV-PA-AEAB-DM-DXXP-XXX 5/ Double operator 5/ Open center 14 4 1 5 1 MV-PA-AFAA-DM-DXXP-XXX MV-PA-AFAB-DM-DXXP-XXX 5/ Pressure center 4 6 7 8 5 67 69 44 46 4 47 48P Internal pilot From port # 14 4 1 5 1 MV-PA-ACAD-DM-DXXP-XXX 14 4 1 5 1 MV-PA-ADAD-DM-DXXP-XXX 14 1 5 MV-PA-AGAD-DM-DXXP-XXX 48 Internal pilot From port #5 External pilot From "1" end MV-PA-ACAE-DM-DXXP-XXX MV-PA-ACAB-DM-DXXP-XXX MV-PA-ADAE-DM-DXXP-XXX MV-PA-ADAB-DM-DXXP-XXX MV-PA-AGAE-DM-DXXP-XXX MV-PA-AGAB-DM-DXXP-XXX 400 SOLENOID OPERATOR DM-D XX P-XXX * 9 XX Voltage X Manual operator XX JA JB JC FB DA DF 110/50, 10/60 (.9W) 0/50, 40/60 (.9W) 4/50, 4/60 (.9W) 4 VDC (1.8W) 4 VDC (5.4W) 4 VDC (1.7W) * Other options available, see page 09. Note: - ISO series, valve and base are ordered separately, see page 41 for base codes. - Ground wire required for 0 volts or higher. OPTIONS 1 Non-locking recessed Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 9 ISO 01 ISO 0 ISO 1 ISO ISO Valve function : MV-PA-AXXX-XX-DXXP-XXX Pilot style : MV-PA-AXXX-DM-DXXP-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) DM Pilot exhaust muffled DP Pilot exhaust piped (#10-) Spool return : MV-PA-AXAX-XX-DXXP-XXX A Standard return B Memory spring return D Standard return with light E Memory spring return with light 195 Consult Precautions page 7 before use, installation or service of MAC Valves..

4 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (5.4 W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 10 PSI External pilot : vacuum to 10 PSI Single/double operator : 0 to 10 PSI, positions : 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/": (5.4 C v ) /4": (6.1 C v ) Class A continuous duty, # AWG leads -15% to +10% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding: 4.8 VA = 1.7 to 1.0 W Energize : 16. ms De-energize : 1.6 ms Options : Sandwich regulator, see Regulators section Spare parts : Pilot valve: DMB-DxxP-xxx Valve to base pressure seal: 16614 Valve mounting screws (x4): 5451 DIMENSIONS Individual base Manifold base 6.5 Dimensions shown are metric (mm) WIXOM,MI. USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 10 PSI 1 P 77,9 50.0.0 4 19.4 40.0 19.9 19.0 MODIF. 9.0.5 8.5 WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL WATTS ELECTRICAL VAC TO 10 PSI 1.0 48.5 160.8 69.0 89.5 106.5 14.0 19.0 65.8 48.8.8 COND 5 1 6. 47.0 48.0 7.8 8.5 DIA THRU MTG HOLES 166.5 107.0 69.0 1.0 5 1 4.5 188.9.1 140.0 175. 96.0 16.0 50. 17. 69.5 54.5 8.5 4 14 1 6.0 79.0.4 7.0 8.5 DIA. THRU MTG HOLES 16.4 99.9 5.8 19.0 9.0 158.0 4.0 78.0 1.0 5 1 59.0 114.0 86.5 51.5 08.0 9.0 55.7 196 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section Remote air valves 197 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Function Port size Flow (Max) Cv Individual mounting Manifold mounting Series Inline Sub-base non plug-in Valve only no base Valve only no base 5/ - 5/ 1/8-1/4 1.0 P. 0 P. 05 400 / /4-1 0.0 P. 09 67 / - / 1 1/ - - 1/ 60.0 P. 1 69 5/ - 5/ /8-1/.1 P. 17 P. 17 ISO 5/ - 5/ 1/ - /4 6. P. 1 P. 1 ISO 199 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 400 Individual mounting Series Inline Sub-base non plug-in 400 67 69 ISO ISO 01 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 400 Function Port size Flow (Max) Individual mounting Series 5/ 5/ 1/8" 1/4" 1.0 C v Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure, also provides high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore.. Wiping effect eliminates sticking. 4. Long service life. 5. Short stroke with high flow. 400 67 69 ISO ISO HOW TO ORDER SINGLE PRESSURE VALVES Pilot air 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 1 14 4 1 14 1 4 14 1 4 14 1 4 14 1/8 NPTF 15 411A-A0H-RA Mod 149 15 41A-A0H-RA 15 451A-A0H-RA 15 461A-A0H-RA 15 471A-A0H-RA 1/4 NPTF 411A-B0H-RA Mod 149 41A-B0H-RA 451A-B0H-RA 461A-B0H-RA 471A-B0H-RA DUAL PRESSURE VALVES Port size 5/ Double operator 4 1 14 1/8 NPTF 1/4 NPTF 15 441A-A0H-RA 441A-B0H-RA 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Note : Compressed air, vacuum, inert gases Single operator: vacuum to 100 PSI Double operator: vacuum to 150 PSI Single oper.: 40 to 150 PSI Double oper., pos.: 0 to 150 PSI, pos.: 5 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to 50 C) 1.0 C v Air signal must be main valve pressure Option : BSPP threads DIMENSIONS Dimensions shown are metric (mm) # 10- OR M5 PILOT PORTS 1.0 15.0 6.0 9.0 76.5 1.5 14 19.0 6.0 5 TO 10 PSI 10.0 1 DOUBLE REMOTE SINGLE REMOTE 04 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 400 Function Port size Flow (Max) Individual mounting Series 5/ 5/ 1/8" 1/4" 1.0 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure, also provides high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore.. Wiping effect eliminates sticking. 4. Long service life. 5. Short stroke with high flow. 400 67 69 ISO ISO HOW TO ORDER SINGLE PRESSURE VALVES Port size 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 5/ Pressure center 4 1 14 4 1 14 1 4 14 1 4 14 1 4 14 Valve less base 15 41A-00H-RA 15 4A-00H-RA 15 45A-00H-RA 15 46A-00H-RA 15 47A-00H-RA 1/8 NPTF 41A-AAH-RA Mod 149 4A-AAH-RA 45A-AAH-RA 46A-AAH-RA 47A-AAH-RA 1/4 NPTF 41A-BAH-RA Mod 149 4A-BAH-RA 45A-BAH-RA 46A-BAH-RA 47A-BAH-RA DUAL PRESSURE VALVES Port size 5/ Double operator 4 1 14 1/8 NPTF 1/4 NPTF 15 44A-AAH-RA 44A-BAH-RA OPTIONS 4A-AAH-RA B for base with flow controls 05 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Note : Compressed air, vacuum, inert gases Single operator: vacuum to 100 PSI Double operator: vacuum to 150 PSI Single oper.: 40 to 150 PSI Double oper., pos.: 0 to 150 PSI, pos.: 5 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to 50 C) 1.0 C v Air signal must be main valve pressure Options : Spare parts : BSPP threads Valve to base pressure seal: 1655 Valve mounting screw (x): 504 Flow control assembly (x): N-04001 DIMENSIONS Dimensions shown are metric (mm) #10- pilot port 91.7 1 14 55.0 5 TO 10 PSI 4 19.05 STOCK REF. LC DOUBLE REMOTE 6.0 SINGLE REMOTE 1.0 0.0 8.5 1/8" - 7 N.P.T.F. 1/4" - 18 N.P.T.F. TYPICAL OPTIONAL FLOW CONTROLS 10.0 1.0 1 14 1 5 9.5 REF. 1 4 8.1 8.10 14.1 4.0 DIA. () MIG. HOLES 5.0 5.00 06 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 67 Individual mounting Series Inline 400 67 69 ISO ISO 07 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 67 Function Port size Flow (Max) Individual mounting Series / /4" - 1 0.0 C v Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure.. Powerful return forces thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life. 400 67 69 ISO ISO HOW TO ORDER Port size Pilot air NO Valve Single Operator NC Valve Double Operator NO Valve NC Valve 10 1 10 1 10 1 10 1 1 1 1 1 /4 NPTF Internal 67A-C-ARA-RA 67A-A-ARA-RA 67A-D4-ARA-RA 67A-B4-ARA-RA 1 NPTF 67A-C-BRA-RA 67A-A-BRA-RA 67A-D4-BRA-RA 67A-B4-BRA-RA /4 NPTF External 67A-C-ARB-RE 67A-A-ARB-RE - - 1 NPTF 67A-C-BRB-RE 67A-A-BRB-RE - - Note : Designation RE required on remote air models with main valve pressures of vacuum to 0 PSI. RE provides an external pilot and should have a pressure range of 0-75 PSI. Since the external pilot supplies the air spring, it must not exceed the remote air pilot pressure. 09 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 67 TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Compressed air, vacuum, inert gases Vacuum to 150 PSI 0 to 150 PSI (must be main valve pressure) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to 50 C) /4" : (14.5 C v ) - 1" : (0.0 C v ) Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 117.9 51.7 18.4 4.0 1 10 1 EP 10 1 17.6 4.0 84.8 190.1 SINGLE REMOTE 169.6 DOUBLE REMOTE OPTIONAL EXTERNAL PILOT PORT 18.7 9.0 59.0 10.5 71.9 9.0 1/8" PILOT PORT 8.7 4.0 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 69 Individual mounting Series Inline 400 67 69 ISO ISO 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series 69 Function Port size Flow (Max) Individual mounting Series / NO-NC, / NO-NC 1 1/ - - 1/ 60.0 C v Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. Bonded spool with minimum friction, shifting in a glass like finished bore. Wiping effect eliminates sticking and contamination 4. Long service life 400 67 69 ISO ISO HOW TO ORDER SINGLE OPERATOR Port size Air Spring Single Operator NO valve Single Operator NC valve 10 1 10 1 1 1/" 1 69A-C-ARA-RA 1 69A-A-ARA-RA " Internal 69A-C-BRA-RA 69A-A-BRA-RA 1/" 69A-C-CRA-RA 69A-A-CRA-RA 1 1/" 69A-C-ARB-RE 69A-A-ARB-RE " External 69A-C-BRB-RE 69A-A-BRB-RE 1/" 69A-C-CRB-RE 69A-A-CRB-RE DOUBLE OPERATOR Port size Double Operator NO valve Double Operator NC valve 10 1 10 1 1 1/" 1 69A-D4-ARB-RA 1 69A-B4-ARB-RA " 69A-D4-BRB-RA 69A-B4-BRB-RA 1/" 69A-D4-CRB-RA 69A-B4-CRB-RA 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 69 TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Compressed air, vacuum, inert gases Vacuum to 150 PSI 0 to 150 PSI (must be main valve pressure) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to 50 C) Cv 60.0 DIMENSIONS Dimensions shown are metric (mm) 50.5 40.0 1/" PORTS SHOWN 50.5 1 1 19.1 58.5 DOUBLE REMOTE 7.5 70.1 1 88.5 SINGLE REMOTE EP 10 10 46.9 1/8" BSP pilot port 80.1 178.1 14 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Individual mounting Series Valve only no base Manifold mounting Valve only no base 400 67 69 ISO ISO 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/ 5/ /8" 1/".1 C v Valve only no base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure.. Powerful return forces thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life. 400 67 69 ISO ISO HOW TO ORDER SINGLE PRESSURE MODELS Air spring 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 14 4 1 14 4 1 14 4 1 14 4 1 5 1 5 1 5 1 5 1 Internal External MV-RA-BACF MV-RA-BACG MV-RA-BBAK MV-RA-BEAK MV-RA-BFAK DUAL PRESSURE MODELS Air spring 5/ Single operator 5/ Double operator 5/ Open center 5/ Pressure center 14 4 1 14 4 1 14 4 1 14 4 1 Internal port # 5 1 MV-RA-BCCH 5 1 5 1 5 1 Internal port #5 MV-RA-BCCJ MV-RA-BDAK MV-RA-BHAK MV-RA-BGAK External MV-RA-BCCG Note: ISO series, valve and base are ordered separately, see page 5 for base code. 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Compressed air, vacuum, inert gases Vacuum to 150 PSI Single/double operator: 0 to 150 PSI position: 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to 50 C) /8" : (.8 Cv) - 1/" : (.1 Cv) Spare parts : Valve to base pressure seal: 16576 Valve mounting screws (x4): 541 DIMENSIONS 10.4 Dimensions shown are metric (mm) 50.0 MODEL VAC TO 150 PSI MODIF. WIXOM,MI USA LIEGE,BELGIUM AUCKLAND,N.Z. 44.9 18 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Individual mounting Series Valve only no base Manifold mounting Valve only no base 400 67 69 ISO ISO 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

R e m o t e a i r v a l v e s Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series 5/ 5/ 1/" /4" 6. C v Valve only no base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure.. Powerful return forces thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life. 400 67 69 ISO ISO HOW TO ORDER SINGLE PRESSURE MODELS Air spring 5/ Single operator 5/ Double operator 5/ Closed center 5/ Open center 14 4 1 14 4 1 14 4 1 14 4 1 5 1 5 1 5 1 5 1 Internal External MV-RA-BACF MV-RA-BACG MV-RA-BBAK MV-RA-BEAK MV-RA-BFAK DUAL PRESSURE MODELS Air spring 5/ Single operator 5/ Double operator 5/ Pressure center 14 4 1 14 4 1 14 4 1 5 1 5 1 5 1 Internal port # MV-RA-BCCH Internal port #5 MV-RA-BCCJ MV-RA-BDAK MV-RA-BGAK External MV-RA-BCCG Note: ISO series, valve and base are ordered separately, see page 9 for base code. 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Flow : Compressed air, vacuum, inert gases Vacuum to 150 PSI Single/double operator: 0 to 150 PSI position: 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to 50 C) 1/" : (5.4 C v ) - /4" : (6. C v ) Spare parts : Valve to base pressure seal: 16614 Valve mounting screws (x4): 5451 DIMENSIONS Dimensions shown are metric (mm) MODIF. WIXOM,MI USA LIEGE,BELGIUM AUCKLAND,N.J. ISO 5599/ 6.4 MODEL VAC TO 150 PSI 160.0 56.8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section Bases according to ISO standards Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O S T A N D A R D S Series Non plug-in individual / manifold base Non plug-in base / manifold Plug-in base / manifold P. 7 P. 9 P. 1 P. 5 P. 9 P. P. 7 P. 41 ISO 01 ISO 0 ISO 1 ISO ISO 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 1 5 4 0 7 9 / 1 Series ISO 01 Series Non plug-in individual / manifold base ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Pilot air Side ports Bottom & 4 ports With all side ports 1/4 NPTF Internal MB-A01A-11 MB-A01A-1 MANIFOLD BASE Port size Pilot air Side ports Bottom & 4 ports With side 1, & 5 ports 1/4 NPTF Internal MM-A01A-11 MM-A01A-1 Notes: - For manifold bases external pilot is common - A base is ordered as internal pilot and can be changed into external pilot by removing pipe plugs from the external pilot ports (individual base). - Manifold base: same base for internal and external pilot, different end plate kits. End plate kit: Internal pilot M-00017-01-01 External pilot M-00017-0-01 Inlet/exhaust isolator: 841 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 01 DIMENSIONS Dimensions shown are metric (mm) Individual 86.45 55.10 1.10 16.40 () 19.80 19.80 5.45 44.45 4.70 1/8"-7 N.P.T.F. () 4.70 4.50 77.45 4.5 4.0 DIA. DRILL - THRU 7.80 1/4"-18 N.T.P.F. () 9.50 () 6.10 4.10 4.10 Manifold LEFT SIDE 7.55 46.40 17.75 1/8"-7 N.P.T.F. () /8"-18 N.P.T.F. () 1/8"-7 N.P.T.F 4.50 1.75 9.10 17.0 55.00 47.00 67.60.40 5.50 8.00 1/8"-7 N.P.T.F. () RIGHT SIDE 7.00 /8"-18 N.P.T.F. () 7.55 17.75 1/8"-7 N.P.T.F. 7.50 1.75 17.0 4.50 9.10 P 47.50 4.00 55.00.40 46.40 0.0 17.50 () 9.50 1/4"-18 N.P.T.F. () 67.60 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 1 5 4 0 7 9 / 1 Series ISO 0 Series Non plug-in individual / manifold base ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Pilot air Side ports Bottom & 4 ports With all side ports 1/8 NPTF Internal MB-A0A-111 MB-A0A-11 MANIFOLD BASE Port size Pilot air Side ports Bottom & 4 ports With side 1, & 5 ports 1/8 NPTF Internal MM-A0A-111 MM-A0A-11 Notes: - For manifold bases external pilot is common - A base is ordered as internal pilot and can be changed into external pilot by removing pipe plugs from the external pilot ports (individual base). - Manifold base: same base for internal and external pilot, different end plate kits. End plate kit: Internal pilot M-00018-01-01 External pilot M-00018-0-01 Inlet/exhaust isolator: 8499 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 0 DIMENSIONS Dimensions shown are metric (mm) Individual 4.00 4.00 8.00 7.00 1/8"-7 N.P.T.F. (7) PLACES 15.00 () 70.5 6.50.50 17.75 17.75 15.00 61.5 0.45 4.5.50 4.5 DIA. DRILL - THRU () 15.00.00 8.00 () 19.00 49.55 5.00 51.00 Manifold LEFT SIDE 11.75.75 55.65 1/8"-7 N.P.T.F. () 1/4"-18 N.P.T.F. () 1/8"-7 N.P.T.F. 5.00 4.00 50.00 4.00 P 17.70 18.0 9.50 50.65 RIGHT SIDE 19.00 1/8"-7 N.P.T.F () 1/4"-18 N.P.T.F () 55.65.75 11.75.70 7.50 1.80 1/8"-7 N.P.T.F. 4.00 () 17.70 () 5.00 P 7.80 7.60 () 50.65 18.0 17.50 () 11.50 () 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO 1 Series Non plug-in base / manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Side & bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 1/4 NPTF MB-A1C-1 MB-A1C- MB-A1C- MB-A1C-4 /8 NPTF MB-A1C-1 MB-A1C- MB-A1C- MB-A1C-4 MANIFOLD BASE Port size Side ports Side & bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 1/4 NPTF MM-A1C-1 MM-A1C- MM-A1C- MM-A1C-4 /8 NPTF MM-A1C-1 MM-A1C- MM-A1C- MM-A1C-4 Manifold fastening kit : N-600-01. Valve blanking plate: MA100. Inlet/exhaust isolator plug: 85. 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 DIMENSIONS Dimensions shown are metric (mm) Individual DIN 5599/1 Manifold 1/8 EXTERNAL PILOT 4 1 5 14,0,0 6,0 6,0 1/8 EXTERNAL PILOT 6,0 5,0 5,0 100,0 16,0 /8 PORTS 6,0 11,0 6,0 50,5 4,5 40,0,5 6,0 1,0 68,0 1,0 Ø 6,5 MTG. HOLES,0 1,0 6,0 Ø 6, MTG. HOLES 50,0 1,0 11,0 4 5 1 9,0 14,0 6,0 1,75 5,5 4 1 5 18,0 4,75 51,0 ± 0, 7,5 50,0 85,0 100,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 60,0 100,0 11,0 6,0 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO 1 Series Plug-in base / manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Wired for Side ports Side ports w/ bottom & 4 ports All side & bottom ports 1/4 NPTF Single solenoid Double solenoid MB-P1A-1-A MB-P1A-1-B MB-P1A--A MB-P1A--B MB-P1A--A MB-P1A--B /8 NPTF Single solenoid Double solenoid MB-P1A-1-A MB-P1A-1-B MB-P1A--A MB-P1A--B MB-P1A--A MB-P1A--B MANIFOLD BASE Port size Wired for Side ports Side ports w/ bottom & 4 ports All side & bottom ports (see note) 1/4 NPTF Single solenoid Double solenoid MM-P1A-1-A MM-P1A-1-B MM-P1A--A MM-P1A--B MM-P1A--A MM-P1A--B /8 NPTF Single solenoid Double solenoid MM-P1A-1-A MM-P1A-1-B MM-P1A--A MM-P1A--B MM-P1A--A MM-P1A--B Note : Ports 1, & 5 are always /8 OPTIONS Manifold options : External pilot MM-P1A-X-X 5 for 1/4" port common external pilot 6 for /8" port common external pilot Terminal strip MM-P1A-XXX-A (N/A with light) J K wired for sgl solenoid wired for double solenoid Base / Manifold option: light(s) MX-P1A-XXX-XJA JA JB DA 110/10 volt 0/40 volt 4 volt Accessories: M-P1001 Valve blanking plate. N-P1007-01 Manifold fastening kit. 85 Inlet/exhaust isolator plug. Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 DIMENSIONS Dimensions shown are metric (mm) Individual 105.5 OPTIONAL BOTTOM PORTS 69.5 45.5 1.5 Ø 6. TYP () 111. P 5 1 15. 15.8. 5.8 6. 8.6 14 5 4 1 17.8 56. 45.7 1/" NPSM CONDUIT 16.0.7.5 45.5 57.5 67. 5..5 57.5 77.4 100. 1.6 107.8 147.5 Manifold 108.5 1" NPSM CONDUIT OPTIONAL COMMON EXTERNAL PILOT 1/8" 17.0 5.0 15.0 1 41.0. 6.0 6.9 COND 5 1 9.7 0.9. 40.5 15.0 4 4.0 0. 4.0 1.0 8.5 65.5 90.7 9.0 115. /8" COMMONS TYP() 159. 1.8 90. 70.7 5.4 5.0.0 8.0 15.5 5 1.7 8.0 40.0 1.0 1 4 OPTIONAL BOTTOM PORTS 90.5 15.9 46. Ø 6. THRU () MTG HOLES 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO Series Non plug-in base / manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 /8 NPTF MB-AB-1 MB-AB- MB-AB- MB-AB-4 1/ NPTF MB-AB-1 MB-AB- MB-AB- MB-AB-4 MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 /8 NPTF MM-AB-1 MM-AB- MM-AB- MM-AB-4 1/ NPTF MM-AB-1 MM-AB- MM-AB- MM-AB-4 Manifold fastening kit : N-600-01. Valve blanking plate: MA00. Inlet/exhaust isolator plug: 89. 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual DIN 5599/1 Manifold 1/8 EXTERNAL PILOT 6,0 8,0 16,0 1,0 4,0 60,0 88,0 6,0 4 1 5 4,0 49,0,0,0 10,0 75,0 16,0 Ø 7,5 MTG. HOLES 54,0 0,0 1/8 EXTERNAL PILOT 1/ - PORTS EACH SIDE 14,0 14,5,0 0,0 1 5 6,0 4,0 4,0 70,0 4,0 4,0 1 5 9,0 4,0 50,5 7,0 9,0 0,5 6,1 Ø 6,5 MTG. HOLES 5,0 64,0 ± 0, 7,0 6,0 98,0 11,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 11,0 19,0 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO Series Plug-in base / manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Wired for Side ports Side ports w/ bottom & 4 ports All side & bottom ports /8 NPTF Single solenoid Double solenoid MB-PA-1-A MB-PA-1-B MB-PA--A MB-PA--B MB-PA--A MB-PA--B 1/ NPTF Single solenoid Double solenoid MB-PA-1-A MB-PA-1-B MB-PA--A MB-PA--B MB-PA--A MB-PA--B MANIFOLD BASE Port size Wired for Side ports Side ports w/ bottom & 4 ports All side & bottom ports (see note) /8 NPTF Single solenoid Double solenoid MM-PA-1-A MM-PA-1-B MM-PA--A MM-PA--B MM-PA--A MM-PA--B 1/ NPTF Single solenoid Double solenoid MM-PA-1-A MM-PA-1-B MM-PA--A MM-PA--B MM-PA--A MM-PA--B Note : Ports 1, & 5 are always 1/ OPTIONS Manifold options : External pilot MM-PA-X-X 5 for /8" port common external pilot 6 for 1/" port common external pilot Terminal strip MM-PA-XXX-A (N/A with light) J K wired for sgl solenoid wired for double solenoid Base / Manifold option: light(s) MX-PA-XXX-XJA JA JB DA 110/10 volt 0/40 volt 4 volt Accessories: M-P001 Valve blanking plate. N-P004-01 Manifold fastening kit. 89 Inlet/exhaust isolator plug. 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual 140.0 6.5 DIA. THRU ()MTG HOLES 70.0 40.0 5.5 4.5 17.0.0 17.8 156.1 DOUBLE SOLENOID 4.5 #1 1 4 5 54.50 #14 48.5 65.5 146.8 SINGLE SOLENOID 5.5 119.5 0.5 1/" N.P.S.M. CONDUIT 51.0 OPTIONAL BOTTOM PORTS 115.9 81.0 #14 EXTERNAL PILOT 1/8" 4 4.5 B C.0 A 4.0 4.5 Dim A B C D E F G #1 EXTERNAL PILOT 1/8" E 55.0 /8 NPTF 5..7 0.6 6.7 40.5 69.4 8. F G 1/ NPTF 4.0 1.0 19.0 5.5 40.0 70.0 84.5 15.0 Manifold 187.0 SINGLE & DOUBLE SOLENOID 18. 105.5 OPTIONAL COMMON EXTERNAL PILOT 1/8" 1-1/4" N.P.S.M. CONDUIT #1 EXTERNAL PILOT 1/8" #14 EXTERNAL PILOT 1/8" 14.1 50.0 50.0 9.5 41.5 8.0 7.0 19.0 17.5 1 5 COND 6.0 0.0 8.0 51.0 CENT. OF 1/" SIDE CYL. 11. 8.5 CENT. OF /8" SIDE CYL. 5.5 71.5 10.0 OPTIONAL BOTTOM PORTS 6.5 DIA. THRU ()MTG HOLES 10.0 45.0.0 6.0 45.0 0.0 18.0 #1 15.0 4 1 5 18.5 #14 45.0 60.0 77.0 5.50 168.00 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO Series Non plug-in base / manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 1/ NPTF MB-AB-1 MB-AB- MB-AB- MB-AB-4 /4 NPTF MB-AB-1 MB-AB- MB-AB- MB-AB-4 MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports and 4. Bottom inlet port 1 1/ NPTF MM-BA-1-A MM-BA--A MM-BA--A MM-BA-4-A /4 NPTF MM-BA-1-A MM-BA--A MM-BA--A MM-BA-4-A Manifold fastening kit: N-P00-01. Valve blanking plate: M-P001. Inlet/exhaust isolator plug: 845. Individual Base Options: MB-AB-XXXF Optional Integral Flow Controls 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

4 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual ISO DIN 5599/1 140,0 5,0 70,0 Ø 8, 4 MTG. HOLES 15,0 17,5 46,0,0 7,0 45,0 49,0 1/8 EXTERNAL PILOT/ REMOTE AIR PILOT PORT ( PLACES),0 1 14 4 0,5 0,5 49,0 45,0,0 4,5 55,0 64,0 1,0 15,0 1 4 49,0 49,0 78,0 156,0 5 9,5 79,0 OPTIONAL BOTTOM PORTS Manifold 6.5 1.0 P 4 50.0 77,9 40.0 19.0 8.5 DIA. THRU MTG HOLES 16.4 99.9 5.8.4 7.0 19.0 9.0 65.8 48.8.8 COND 5 1 7.8 47.0 48.0 6. 78.0 1.0 5 1 59.0 188.9.1 96.0 140.0 16.0 175. 50. 17. 08.0 9.0 55.7 40 Consult Precautions page 7 before use, installation or service of MAC Valves..

B a s e s a c c o r d i n g t o I S O 5 5 9 9 / 1 Series ISO Series Plug-in manifold ISO 01 ISO 0 ISO 1 ISO ISO HOW TO ORDER MANIFOLD BASE Port size Wired for Side ports Side ports w/ bottom & 4 ports All side & bottom ports (see note) 1/ NPTF Single solenoid Double solenoid MM-PA-1-A MM-PA-1-B MM-PA--A MM-PA--B MM-PA--A MM-PA--B /4 NPTF Single solenoid Double solenoid MM-PA-1-A MM-PA-1-B MM-PA--A MM-PA--B MM-PA--A MM-PA--B Note : Ports 1, & 5 are always /4 OPTIONS Manifold options : External pilot MM-PA-X-X 5 for 1/" port common external pilot 6 for /4" port common external pilot Terminal strip MM-PA-XXX-A J K wired for sgl solenoid wired for double solenoid light(s) MM-PA-XXX-XJA JA JB DA 110/10 volt 0/40 volt 4 volt Accessories: M-P001 Valve blanking plate. N-P00-01 Manifold fastening kit. 845 Inlet/exhaust isolator plug. 41 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) WIXOM,MI. USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 10 PSI 19.4 9.0.5 8.5 1.0 48.5 69.0 89.5 106.5 19.0 14.0 8.5 DIA THRU MTG HOLES 166.5 107.0 69.0 1.0 69.5 8.5 5 1 4.5 54.5 4 14 1 6.0 79.0 158.0 4.0 86.5 51.5 114.0 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section 4 Pressure regulators 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with air pilot adjust Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with air pilot adjust Sandwich pressure regulator with manual adjust knob Sandwich pressure regulator with manual adjust knob Non plug-in sandwich pressure regulator with manual adjust Plug-in sandwich pressure regulator with air pilot adjust Non plug-in sandwich pressure regulator with manual adjust Non plug-in sandwich pressure regulator with manual adjust knob Non plug-in sandwich pressure regulator with air pilot adjust Plug-in sandwich pressure regulator with manual adjust knob Plug-in sandwich pressure regulator with air pilot adjust Non plug-in sandwich pressure regulator with manual adjust knob Non plug-in sandwich pressure regulator with air pilot adjust Plug-in sandwich pressure regulator with manual adjust knob Plug-in sandwich pressure regulator with air pilot adjust Non plug-in sandwich pressure regulator with manual adjust knob Non plug-in sandwich pressure regulator with air pilot adjust Plug-in sandwich pressure regulator with manual adjust knob Plug-in sandwich pressure regulator with air pilot adjust P. 47 P. 49 P. 51 P. 5 P. 55 P. 57 P. 59 P. 61 P. 6 P. 65 P. 67 P. 69 P. 71 P. 7 P. 75 P. 77 P. 79 P. 81 P. 8 P. 85 P. 87 P. 89 P. 91 P. 9 P. 95 P. 97 PR7A PR4B PR46A PR47A PR48B PR9C PR9A PRA01A PRA0A PRA1A PRP1A PRAD PRPB PRAC PRPB 45 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR7A Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "NON PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) Note: Gage No gage port With gage Port (plugged) Regulating pressure range for above models is 0 to 10 PSI For other ranges, see below. Single pressure PR7A-FAAA PR7A-FABA PR9A OPTIONS Adjustment : PR7A-FXXX B for slotted stem K for slotted stem with locknut Pressure range : PR7A-XXXA B for 0 to 80 PSI C for 0 to 0 PSI PRA01A PRA0A PRA1A PRP1A PRAD PRPB PRAC PRPB 47 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR7A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.4 C v Spare parts : Pressure regulator (less sandwich block) : PR7A-G0AA (knob), PR7A-C0AA (slotted stem), PR7A-L0AA (slotted stem with locknut) Gages : 4177-160 (0 to 160 PSI, mm) 4177-100 (0 to 100 PSI, mm) 4177-060 (0 to 60 PSI, mm) DIMENSIONS Dimensions shown are metric (mm) 98.4 APPROX E F 84. APPROX 10.8 APPROX 48 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR4B Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C NON PLUG-IN SANDWICH REGULATORS Gage Regulator "1 end Internal pilot Regulator "1 end External pilot No gage port With gage Port PR4B-BAAA PR4B-BABA PR4B-BBAA PR4B-BBBA PR9A PLUG-IN SANDWICH REGULATORS Gage No gage port With gage Port Regulator "1 end Internal pilot PR4B-AAAA PR4B-AABA Notes: - External pilot regulator required only when supply pressure (primary) to the valve is below the minimum operating pressure of the 4 series valve. - When an internal pilot regulator is used with the 4 series valve, the valve should be ordered as external pilot and the base should be ordered as internal pilot. This ensures that the pilot supply is not regulated. If an internal pilot valve and base are used with an internal pilot regulator, the pilot supply is regulated. Regulator "1 end External pilot PR4B-ABAA PR4B-ABBA PRA01A PRA0A PRA1A PRP1A Example: Valve 4B-AM D -AA A -GxxP-xxx with PR4B-AAAA Internal pilot option in base External pilot option in valve PRAD OPTIONS Pressure range : PR4B-AAAA PRPB A 0 to 10 PSI B 0 to 80 PSI C 0 to 40 PSI PRAC PRPB 49 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR4B TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.5 C v Spare parts : Pressure regulator (less sandwich block) : PR4B-C0xx Gage port plug: N-PE00 #10 - to 1/8 adapter : N-5005 Gage: 4177-160 (0 to 160 PSI, mm) 4177-100 (0 to 100 PSI, mm) 4177-060 (0 to 60 PSI, mm) DIMENSIONS Dimensions shown are metric (mm) NON PLUG-IN 11. 5 1 166.6 PLUG-IN 101.7 - + - + - + - + L O C K L O C K L O C K L O C K X 5 4 4 4 4 1 180.6 50 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR46A Series Sandwich-pressure regulator OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. 6. Single pressure regulator. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" AND "NON PLUG-IN" VALVES Gauge For plug-in valves For non plug-in valves Gauge port (plugged) PR46A-AAAA PR46A-BAAA PR9A OPTIONS Pressure range : PR46A-AAA A A B C 0 to 10 PSI 0 to 80 PSI 0 to 0 PSI PRA01A PRA0A A B C Manual adjust with slotted screwdriver stem Manual adjust with adjusting knob Manual adjust with slotted screwdriver stem and locknut PRA1A 0 Regulator only (No sandwich block) Notes : gadges must be ordered separately, not included with regulator. Recommended gage : 4165-150 (15 mm) PRP1A PRAD PRPB PRAC PRPB 51 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR46A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) Cv 0,1 DIMENSIONS Dimensions shown are metric (mm) NON PLUG-IN PLUG-IN 7.4 7.8 1/4" COMMONS 1/4" COMMONS 147.1 EXH IN IN EXH COND 8.5.8 105..9 10.1 1"-11 1/ NPS 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR47A Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES (KNOB ADJUSTMENT) Gage No gage port With gage Port Single pressure PR47A-EAAA PR47A-EABA PR9A REGULATORS FOR "NON PLUG-IN" VALVES (KNOB ADJUSTMENT) Gage No Gage port Single pressure PR47A-FAAA PRA01A OPTIONS With Gage Port PR47A-FABA PRA0A Pressure range : PR47A-XXXA PRA1A A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI Adjustment for : Plug-in regulator PR47A-EXXX E Knob A Screwdriver slot J Screwdriver slot with locknut Non plug-in regulator PR47A-FXXX F Knob B Screwdriver slot K Screwdriver slot with locknut PRP1A PRAD PRPB PRAC PRPB 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR47A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.4 C v Spare parts : Pressure regulator (less sandwich block) : PR47A-G0AA (knob), PR47A-C0AA (screwdriver slot), PR47A-L0AA (screwdriver slot with locknut) Gage: 4177-160 (0 to 160 PSI, mm) 4177-100 (0 to 100 PSI, mm) 4177-060 (0 to 60 PSI, mm) DIMENSIONS Dimensions shown are metric (mm) 00.8 11.7 P 1 5 54 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR48B Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C NON PLUG-IN SANDWICH REGULATORS (KNOB ADJUSTMENT) Gage Regulator "1 end Internal pilot Regulator "1 end External pilot Gage port PR48B-BAAA PR48B-BBAA PR9A PLUG-IN SANDWICH REGULATORS (KNOB ADJUSTMENT) OPTIONS Pressure range : PR48B-XXXA Gage Gage port A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI Regulator "1 end Internal pilot PR48B-AAAA Notes: - External pilot regulator required only when supply pressure (primary) to the valve is below the minimum operating pressure of the 48 series valve. - When an internal pilot regulator is used with the 48 series valve, the valve should be ordered as external pilot and the base should be ordered as internal pilot. This ensures that the pilot supply is not regulated. If an internal pilot valve and base are used with an internal pilot regulator, the pilot supply is regulated. Example: Valve 48B-AM D -AA A -GxxP-xxx with PR48B-AAAA Internal pilot option in base External pilot option in valve Regulator "1 end External pilot PR48B-ABAA PRA01A PRA0A PRA1A PRP1A PRAD PRPB Adjustment for : Plug-in regulator PR48B-AXXX Non plug-in regulator PR48B-BXXX PRAC A Knob D Screwdriver slot G Screwdriver slot with locknut B Knob E Screwdriver slot H Screwdriver slot with locknut PRPB 55 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR48B TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.8 C v Spare parts : Pressure regulator (less sandwich block) : PR48B-C0AA (knob), PR48B-F0AA (screwdriver slot), PR48B-J0AA (screwdriver slot with locknut) Gage: 4177-160 (0 to 160 PSI, mm) 4177-100 (0 to 100 PSI, mm) 4177-060 (0 to 60 PSI, mm) DIMENSIONS Dimensions shown are metric (mm) NON PLUG-IN 144.5 EP 5 1 1. PLUG-IN 14.0 EP 5 4 4 4 4 COND 1 6.4 56 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9C Series Sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES Gage Regulator A end Single pressure Regulator B end Single pressure Regulator A * end with by-pass end plate B end Regulator B * end with by-pass end plate A end Regulator * both ends PR9A Gage port only (plugged) PR9C-EAAA PR9C-EBAA PR9C-ECAA PR9C-EDAA PR9C-EEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9C-EABA PR9C-EACA Note: above models are coded for use with single solenoid valves PR9C-EBBA PR9C-EBCA PR9C-ECBA PR9C-ECCA PR9C-EDBA PR9C-EDCA PR9C-EEBA PR9C-EECA PRA01A PRA0A REGULATORS FOR "NON PLUG-IN" VALVES PRA1A Gage Gage port only (plugged) Regulator A end Single pressure PR9C-GAAA Regulator B end Single pressure PR9C-GBAA Regulator A * end with by-pass end plate B end PR9C-GCAA Regulator B * end with by-pass end plate A end PR9C-GDAA Regulator * both ends PR9C-GEAA PRP1A Gage with face perpendicular to manual operator Gage with face parallel to manual operator * For use with dual pressure valves. PR9C-GABA PR9C-GACA PR9C-GBBA PR9C-GBCA PR9C-GCBA PR9C-GCCA PR9C-GDBA PR9C-GDCA PR9C-GEBA PR9C-GECA PRAD PRPB PLUG-IN OPTIONS PR9C-EXXX F for double solenoid valve PRAC PRPB 57 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9C TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.8 C v Spare parts : R-900 : regulator end plate kit Gage kit 0-160 PSI: N-9006-01 R-900-01: regulator by-pass end plate kit Pressure regulator (less sandwich block) : PR9C-H0AA DIMENSIONS Dimensions shown are metric (mm) 0.56 APPROX. W/ DOUBLE REGULATOR MANUAL OPERATOR WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL MODIF. ELECTRICAL WATTS VAC TO 10 PSI 15.0 APPROX. GAGE PILOT 47.5 APPROX. EP EX IN 145.88 58 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9C Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR PLUG-IN VALVES (CODED FOR KNOB ADJUSTMENT) Gage Regulator A end Single pressure Regulator B end Single pressure Regulator A * end with by-pass end plate B end Regulator B * end with by-pass end plate A end Regulator * both ends PR9A No Gage PR9C-JAAA PR9C-JBAA PR9C-JCAA PR9C-JDAA PR9C-JEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9C-JABA PR9C-JACA Note: above models are coded for use with single solenoid valves PR9C-JBBA PR9C-JBCA PR9C-JCBA PR9C-JCCA PR9C-JDBA PR9C-JDCA PR9C-JEBA PR9C-JECA PRA01A PRA0A REGULATORS FOR NON PLUG-IN VALVES (CODED FOR KNOB ADJUSTMENT) Gage Regulator A end Single pressure Regulator B end Single pressure Regulator A * end with by-pass end plate B end Regulator B * end with by-pass end plate A end Regulator * both ends PRA1A No Gage PR9C-LAAA PR9C-LBAA PR9C-LCAA PR9C-LDAA PR9C-LEAA PRP1A Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9C-LABA PR9C-LACA PR9C-LBBA PR9C-LBCA PR9C-LCBA PR9C-LCCA PR9C-LDBA PR9C-LDCA PR9C-LEBA PR9C-LECA PRAD * For use with dual pressure valves. Notes: - Regulating range for above models is 0 to 10 PSI. For other ranges, see technical data page. PRPB OPTIONS Regulator less sandwich block PR9C-X0XX Other adjustment PR9C-XXXX PRAC M D S Knob Slotted stem Slotted stem with locknut A B C K N P R Slotted stem, single solenoid Slotted stem, double solenoid Slotted stem, non plug-in Knob, double solenoid Slotted stem w/ locknut, single solenoid Slotted stem w/ locknut, double solenoid Slotted stem w/ locknut, non plug-in PRPB 59 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9C TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.8 C v Spare parts : Options: R-900 : end plate kit R-900-01: by-pass end plate kit Gage kit 0 160 PSI : N-9006-01 Gage kit 0 100 PSI : N-9006-0 Gage kit 0 60 PSI : N-9006-0 Pressure range: PR9C-xxxA (A 0 to 10 PSI) B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI A end, 0 to 80 PSI B end E 0 to 10 PSI B end, 0 to 80 PSI A end F 0 to 10 PSI A end, 0 to 0 PSI B end G 0 to 10 PSI B end, 0 to 0 PSI A end H 0 to 80 PSI A end, 0 to 0 PSI B end J 0 to 80 PSI B end, 0 to 0 PSI A end DIMENSIONS Dimensions shown are metric (mm) 41.0 APPROX. W/ DOUBLE REGULATOR MANUAL OPERATOR WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL MODIF. ELECTRICAL WATTS VAC TO 10 PSI 15.0 APPROX. GAGE PILOT 47.5 APPROX. EP EX IN 171.5 60 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9C Series Sandwich selector pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) Gage Select to A port Regulator A end By-pass plate B end Select to B port Regulator B end By-pass plate A end Select to A port Reg. both ends A end low press. B end high press. Select to B port Reg. both ends A end high press. B end low press. PR9A No Gage Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9C-JPAA PR9C-JPBA PR9C-JPCA Note: above models are coded for use with single solenoid valves Gage No Gage Gage with face perpendicular to manual operator Gage with face parallel to manual operator Select to A port Regulator A end By-pass plate B end PR9C-LPAA PR9C-LPBA PR9C-LPCA PR9C-JRAA PR9C-JRBA PR9C-JRCA REGULATORS FOR "NON PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) Select to B port Regulator B end By-pass plate A end PR9C-LRAA PR9C-LRBA PR9C-LRCA Notes: - Regulating range for above models is 0 to 10 PSI. For other ranges, see technical data page - Use single pressure valve for all above models. PR9C-JSAA PR9C-JSBA PR9C-JSCA Select to A port Reg. both ends A end low press. B end high press. PR9C-LSAA PR9C-LSBA PR9C-LSCA PR9C-JTAA PR9C-JTBA PR9C-JTCA Select to B port Reg. both ends A end high press. B end low press. PR9C-LTAA PR9C-LTBA PR9C-LTCA PRA01A PRA0A PRA1A PRP1A PRAD PRPB OPTIONS Regulator less sandwich block PR9C-X0XX M Knob D Slotted stem S Slotted stem with locknut Other adjustment PR9C-XXXX A B C K N P R Slotted stem, single solenoid Slotted stem, double solenoid Slotted stem, non plug-in Knob, double solenoid Slotted stem w/ locknut, single solenoid Slotted stem w/ locknut, double solenoid Slotted stem w/ locknut, non plug-in PRAC PRPB 61 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9C TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 0.8 C v Spare parts : Options : R-900 : end plate kit R-900-01: by-pass end plate kit Gage kit 0 160 PSI : N-9006-01 Gage kit 0 100 PSI : N-9006-0 Gage kit 0 60 PSI : N-9006-0 Pressure range: PR9C-xxxA (A 0 to 10 PSI) B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI A end, 0 to 80 PSI B end E 0 to 10 PSI B end, 0 to 80 PSI A end F 0 to 10 PSI A end, 0 to 0 PSI B end G 0 to 10 PSI B end, 0 to 0 PSI A end H 0 to 80 PSI A end, 0 to 0 PSI B end J 0 to 80 PSI B end, 0 to 0 PSI A end DIMENSIONS Dimensions shown are metric (mm) 41.0 APPROX. W/ DOUBLE REGULATOR MANUAL OPERATOR WIXOM,MI. USA LIEGE,BELGIUM AUCKLAND,N.Z. MODEL MODIF. ELECTRICAL WATTS VAC TO 10 PSI 15.0 APPROX. GAGE PILOT 47.5 APPROX. EP EX IN 171.5 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9A Series Sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES Gage Regulator A end Single pressure Regulator B end Single pressure Regulator A * end with by-pass end plate B end Regulator B * end with by-pass end plate A end Regulator * both ends PR9A Gage port only (plugged) PR9A-DAAA PR9A-DBAA PR9A-DCAA PR9A-DDAA PR9A-DEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-DABA PR9A-DACA PR9A-DBBA PR9A-DBCA PR9A-DCBA PR9A-DCCA PR9A-DDBA PR9A-DDCA PR9A-DEBA PR9A-DECA PRA01A PRA0A REGULATORS FOR "NON PLUG-IN" VALVES PRA1A Gage Gage port only (plugged) Regulator A end Single pressure PR9A-EAAA Regulator B end Single pressure PR9A-EBAA Regulator A * end with by-pass end plate B end PR9A-ECAA Regulator B * end with by-pass end plate A end PR9A-EDAA Regulator * both ends PR9A-EEAA PRP1A Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-EABA PR9A-EACA PR9A-EBBA PR9A-EBCA Note: Above models may be used with either single or double solenoid valves. * For use with dual pressure valves. PR9A-ECBA PR9A-ECCA PR9A-EDBA PR9A-EDCA PR9A-EEBA PR9A-EECA PRAD PRPB PRAC PRPB 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

ELECTRICAL WIXOM,MI.USA LIEGE,BELGIUM VAC TO 10 PSI WATTS MODIF. 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).4 C v Spare parts : Regulator end plate kit: R-9004 Regulator by-pass end plate kit: R-9004-01 Gage kit: N-9006-01 (0 to 160 PSI) Pressure regulator (less sandwich block): PR9A-F0AA DIMENSIONS Dimensions shown are metric (mm) MANUAL OPERATOR MODEL AUCKLAND,N.Z. 17.60 APPROX. GAGE IN EX CONDUIT 08.5 APPROX. WITH SINGLE REGULATOR 57.00 76.50 APPROX. WITH DOUBLE REGULATOR 64 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9A Series Sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) Gage Regulator A end Single pressure Regulator B end Single pressure Regulator A * end with by-pass end plate B end Regulator B * end with by-pass end plate A end Regulator * both ends PR9A Gage port only (plugged) PR9A-GAAA PR9A-GBAA PR9A-GCAA PR9A-GDAA PR9A-GEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-GABA PR9A-GACA PR9A-GBBA PR9A-GBCA PR9A-GCBA PR9A-GCCA PR9A-GDBA PR9A-GDCA PR9A-GEBA PR9A-GECA PRA01A PRA0A REGULATORS FOR "NON PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) PRA1A Gage Gage port only (plugged) Regulator A end Single pressure PR9A-HAAA Regulator B end Single pressure PR9A-HBAA Regulator A * end with by-pass end plate B end PR9A-HCAA Regulator B * end with by-pass end plate A end PR9A-HDAA Regulator * both ends PR9A-HEAA PRP1A Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-HABA PR9A-HACA PR9A-HBBA PR9A-HBCA PR9A-HCBA PR9A-HCCA * For use with dual pressure valves. Note: Regulating range for above models is 0 to 10 PSI. For other ranges, see technical data page. PR9A-HDBA PR9A-HDCA PR9A-HEBA PR9A-HECA PRAD PRPB OPTIONS Regulator less sandwich block PR9A-X0XX J Knob C Slotted stem M Slotted stem with locknut Note: Above models may be used with either single or double solenoid valves. Other adjustment PR9A-XXXX A B K L Slotted stem, plug-in Slotted stem, non plug-in Slotted stem w/ locknut, plug-in Slotted stem w/ locknut, non plug-in PRAC PRPB 65 Consult Precautions page 7 before use, installation or service of MAC Valves..

MODEL ELECTRICAL WIXOM,MI.USA LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO 10 PSI WATTS MODIF. 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).4 C v Spare parts : Option: Regulator end plate kit :R-9004 Regulator by-pass end plate kit : R-9004-01. Gage kit 0 160 PSI : N-9006-01 Gage kit 0 100 PSI : N-9006-0 Gage kit 60 PSI : N-9006-0 Pressure range: PR9A-xxxA (A 0 to 10 PSI) B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI A end, 0 to 80 PSI B end E 0 to 10 PSI B end, 0 to 80 PSI A end F 0 to 10 PSI A end, 0 to 0 PSI B end G 0 to 10 PSI B end, 0 to 0 PSI A end H 0 to 80 PSI A end, 0 to 0 PSI B end J 0 to 80 PSI B end, 0 to 0 PSI A end DIMENSIONS Dimensions shown are metric (mm) MANUAL OPERATOR 17.60 APPROX. GAGE IN EX CONDUIT 4.65 APPROX. WITH SINGLE REGULATOR 57.00 47.0 APPROX. WITH DOUBLE REGULATOR 66 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PR9A Series Sandwich selector pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR "PLUG-IN" VALVES (CODED FOR KNOB ADJUSTMENT) Gage Select to A port Regulator A end By-pass plate B end Select to B port Regulator B end By-pass plate A end Select to A port Reg. both ends A end low press. B end high press. Select to B port Reg. both ends A end high press. B end low press. PR9A Gage port only (plugged) Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-GPAA PR9A-GPBA PR9A-GPCA PR9A-GRAA PR9A-GRBA PR9A-GRCA PR9A-GSAA PR9A-GSBA PR9A-GSCA PR9A-GTAA PR9A-GTBA PR9A-GTCA PRA01A PRA0A REGULATORS FOR "NON PLUG-IN" VALVES Gage Gage port only (plugged) Gage with face perpendicular to manual operator Gage with face parallel to manual operator PR9A-HPAA PR9A-HPBA PR9A-HPCA PR9A-HRAA PR9A-HRBA PR9A-HRCA Notes: - Regulating range for above models is 0 to 10 PSI. For other ranges, see technical data page - Use single pressure valve for all above models. OPTIONS Select to A port Regulator A end By-pass plate B end Select to B port Regulator B end By-pass plate A end Select to A port Reg. both ends A end low press. B end high press. PR9A-HSAA PR9A-HSBA PR9A-HSCA Select to B port Reg. both ends A end high press. B end low press. PR9A-HTAA PR9A-HTBA PR9A-HTCA PRA1A PRP1A PRAD PRPB Regulator less sandwich block Other adjustment PR9A-X0XX PR9A-XXXX J Knob A C Slotted stem B M Slotted stem with locknut K L Note: Above models may be used with either single or double solenoid valves. Slotted stem, plug-in Slotted stem, non plug-in Slotted stem w/ locknut, plug-in Slotted stem w/ locknut, non plug-in PRAC PRPB 67 Consult Precautions page 7 before use, installation or service of MAC Valves..

MODEL ELECTRICAL WIXOM,MI.USA LIEGE,BELGIUM AUCKLAND,N.Z. VAC TO 10 PSI WATTS MODIF. 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR9A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).4 C v Spare parts : Regulator end plate kit :R-9004 Regulator by-pass end plate kit : R-9004-01. Gage kit 0 160 PSI : N-9006-01 Gage kit 0 100 PSI : N-9006-0 Gage kit 0 60 PSI : N-9006-0 Option: Pressure range: PR9A-xxxA (A 0 to 10 PSI) B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI A end, 0 to 80 PSI B end E 0 to 10 PSI B end, 0 to 80 PSI A end F 0 to 10 PSI A end, 0 to 0 PSI B end G 0 to 10 PSI B end, 0 to 0 PSI A end H 0 to 80 PSI A end, 0 to 0 PSI B end J 0 to 80 PSI B end, 0 to 0 PSI A end DIMENSIONS Dimensions shown are metric (mm) MANUAL OPERATOR 17.60 APPROX. GAGE IN EX CONDUIT 4.65 APPROX. WITH SINGLE REGULATOR 57.00 47.0 APPROX. WITH DOUBLE REGULATOR 68 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRA01A Series Non plug-in sandwich pressure regulator with manual adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs and space in comparison with inline regulators. Compact all-included units. Large orifice provides high flow 4. Various functions available 5. Simple, reliable and solid design PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C Pilot Internal External Single pressure Regulator 1 end PRA01A-AAAA PRA01A-BAAA Dual pressure Regulator 1 end with by-pass 14 end PRA01A-ABAA PRA01A-BBAA * Dual pressure Regulator 14 end with by-pass 1 end PRA01A-ADAA PRA01A-BDAA * Dual pressure Regulator both ends PRA01A-AEAA PRA01A-BEAA * PR9A Above models are for manual adjust with knob For other manual adjustments and pressure ranges, see Options. Note: Add 9 after part number for regulator block assembled to valve. * To be used with dual pressure valves. OPTIONS Adjustments : PRA01A XXXX A B G H K L Manual adjust with knob Internal pilot Manual adjust with knob External pilot Manual adjust with screwdriver slot Internal pilot Manual adjust with screwdriver slot External pilot Manual adjust with screwdriver slot with locknut Internal pilot Manual adjust with screwdriver slot with locknut External pilot Regulated Pressure range : PRA01A XXXX A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI 14 end - 0 to 80 PSI 1 end E 0 to 10 PSI 1 end - 0 to 80 PSI 14 end F 0 to 10 PSI 14 end - 0 to 0 PSI 1 end G 0 to 10 PSI 1 end - 0 to 0 PSI 14 end H 0 to 80 PSI 14 end - 0 to 0 PSI 1 end J 0 to 80 PSI 1 end - 0 to 0 PSI 14 end PRA01A PRA0A PRA1A PRP1A PRAD PRPB PRAC PRPB 69 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA01A TECHNICAL DATA Fluid : Pressure supply : Regulating range : Lubrication : Filtration : Temperature range : Compressed air, inert gases Higher than maximum regulated pressure (max. 8,5 bar) 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) DIMENSIONS Dimensions shown are metric (mm) 9.5 11.6 4.4 4.4 1/4" OR 1/8" PORTS (5) 1/4 SHOWN 6.4 179. 70 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRA01A Series Non plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators. Compact all-included units. Large orifice provides high flow 4. Various functions available 5. Simple, reliable and solid design PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C Pilot Internal External Single pressure Regulator 1 end PRA01A-DAAA PRA01A-EAAA Dual pressure Regulator 1 end with by-pass 14 end PRA01A-DBAA PRA01A-EBAA * Dual pressure Regulator 14 end with by-pass 1 end PRA01A-DDAA PRA01A-EDAA * Dual pressure Regulator both ends PRA01A-DEAA PRA01A-EEAA * PR9A Note : Only pressure range available for air adjust regulator is 0-10 PSI. * To be used with dual pressure valves. PRA01A PRA0A PRA1A PRP1A PRAD PRPB PRAC PRPB 71 Consult Precautions page 7 before use, installation or service of MAC Valves..

PILOT GAGE PILOT GAGE PILOT GAGE PILOT GAGE 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA01A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Compressed air, inert gases Higher than maximum regulated pressure 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) DIMENSIONS Dimensions shown are metric (mm) 4.5 9.1 1.7 17. 11.0 16.9 1/8" 1 & 14 160.1 8.1 6.1 66.8 9.5 47.5 4.0 1/8" 1 & 14 /8" 1, &5 144.0 1/4" SHOWN 9.5 19.5 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRA0A Series Non plug-in sandwich pressure regulator with manual adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs and space in comparison with inline regulators. Compact all-included units. Large orifice provides high flow 4. Various functions available 5. Simple, reliable and solid design PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C Pilot Internal External Single pressure Regulator 1 end PRA0A-AAAA PRA0A-BAAA Dual pressure Regulator 1 end with by-pass 14 end PRA0A-ABAA PRA0A-BBAA * Dual pressure Regulator 14 end with by-pass 1 end PRA0A-ADAA PRA0A-BDAA * Dual pressure Regulator both ends PRA0A-AEAA PRA0A-BEAA * PR9A Above models are for manual adjust with knob For other manual adjustments and pressure ranges, see Options. Note: Add 9 after part number for regulator block assembled to valve. * To be used with dual pressure valves. OPTIONS Adjustments : PRA0A XXXX A B G H K L Manual adjust with knob Internal pilot Manual adjust with knob External pilot Manual adjust with screwdriver slot Internal pilot Manual adjust with screwdriver slot External pilot Manual adjust with screwdriver slot with locknut Internal pilot Manual adjust with screwdriver slot with locknut External pilot Regulated Pressure range : PRA0A XXXX A 0 to 10 PSI B 0 to 80 PSI C 0 to 0 PSI D 0 to 10 PSI 14 end - 0 to 80 PSI 1 end E 0 to 10 PSI 1 end - 0 to 80 PSI 14 end F 0 to 10 PSI 14 end - 0 to 0 PSI 1 end G 0 to 10 PSI 1 end - 0 to 0 PSI 14 end H 0 to 80 PSI 14 end - 0 to 0 PSI 1 end J 0 to 80 PSI 1 end - 0 to 0 PSI 14 end PRA01A PRA0A PRA1A PRP1A PRAD PRPB PRAC PRPB 7 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA0A TECHNICAL DATA Fluid : Pressure supply : Regulating range : Lubrication : Filtration : Temperature range : Compressed air, inert gases Higher than maximum regulated pressure 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) DIMENSIONS 144.0 Dimensions shown are metric (mm) 8.0 110.5 19. 5. 51. 1/8" ALL PORTS (7) 19.4 74 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRA1A Series Non plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRA1A-GAAA PRA1A-GCAA PRA1A-GBAA PRA1A-GDAA PRA1A-GEAA Gage perpendicular to regulator(s) PRA1A-GABA PRA1A-GCBA PRA1A-GBBA PRA1A-GDBA PRA1A-GECA PRA01A Gage parallel to regulator(s) PRA1A-GADA PRA1A-GCDA PRA1A-GBDA PRA1A-GDDA PRA1A-GEEA PRA0A EXTERNAL PILOT AND REMOTE AIR Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRA1A-HAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRA1A-HCAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRA1A-HBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRA1A-HDAA PRA1A-HEAA PRA1A PRP1A Gage perpendicular to regulator(s) Gage parallel to regulator(s) PRA1A-HABA PRA1A-HADA PRA1A-HCBA PRA1A-HCDA * - To be used with dual pressure valves. Note : regulating range for above models is 0-10 PSI. For other ranges see technical data page. ADJUSTMENT OPTIONS PRA1A-XXXX A B K L for slotted stem adjustment (internal pilot) for slotted stem adjustment (external/remote air) for slotted stem with locknut (internal pilot) for slotted stem with locknut (external/remote air) PRA1A-HBBA PRA1A-HBDA PRA1A-HDBA PRA1A-HDDA PRA1A-HECA PRA1A-HEEA Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #56. PRAD PRPB PRAC PRPB 75 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA1A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 10 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.0 C v Spare parts : Pressure regulator (less sandwich block) : PRA1A-J0AA (KNOB), PRA1A-C0AA (SLOTTED STEM), PRA1A-M0AA (SLOTTED STEM WITH LOCKNUT). Gage : N-8016-01 (0-10 PSI perpendicular) N-8016-0 (0-10 PSI parallel) N-8016-0 (0-80 PSI perpendicular) N-8016-04 (0-80 PSI parallel) N-8016-05 (0-0 PSI perpendicular) N-8016-06 (0-0 PSI parallel) Regulating range options : PRA1A-XXXA Replace by B Replace by C Replace by D Replace by E Replace by F Replace by G Replace by H Replace by J - 0 to 80 PSI - 0 to 0 PSI - 0 to 10 PSI on 14 end - 0 to 80 PSI on 1 end - 0 to 10 PSI on 1 end - 0 to 80 PSI on 14 end - 0 to 10 PSI on 14 end - 0 to 0 PSI on 1 end - 0 to 10 PSI on 1 end - 0 to 0 PSI on 14 end - 0 to 80 PSI on 14 end - 0 to 0 PSI on 1 end - 0 to 80 PSI on 1 end - 0 to 0 PSI on 14 end DIMENSIONS 14.7 Dimensions shown are metric (mm) 14.7 97. 76 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRA1A Series Non plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRA1A-DAAA PRA1A-DCAA PRA1A-DBAA PRA1A-DDAA PRA1A-DEAA Gage perpendicular to regulator(s) PRA1A-DABA PRA1A-DCBA PRA1A-DBBA PRA1A-DDBA PRA1A-DECA PRA01A Gage parallel to regulator(s) PRA1A-DADA PRA1A-DCDA PRA1A-DBDA PRA1A-DDDA PRA1A-DEEA PRA0A EXTERNAL PILOT AND REMOTE AIR Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRA1A-EAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRA1A-ECAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRA1A-EBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRA1A-EDAA PRA1A-EEAA PRA1A PRP1A Gage perpendicular to regulator(s) PRA1A-EABA PRA1A-ECBA PRA1A-EBBA PRA1A-EDBA PRA1A-EECA PRAD Gage parallel to regulator(s) * - To be used with dual pressure valves. PRA1A-EADA PRA1A-ECDA PRA1A-EBDA PRA1A-EDDA PRA1A-EEEA Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #56. PRPB PRAC PRPB 77 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA1A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.0 C v Spare parts : Pressure regulator (less sandwich block) : PRA1A-F0AA. Gage : N-8016-01 (0-10 PSI perpendicular) N-8016-0 (0-10 PSI parallel) DIMENSIONS 194.1 194.1 Dimensions shown are metric (mm) 4.6 78 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRP1A Series Plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER REGULATORS FOR INTERNAL PILOT (CODED FOR KNOB ADJUSTMENT) Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9C PR9A Gage port only PRP1A-GAKA PRP1A-GCKA PRP1A-GBKA PRP1A-GDKA PRP1A-GEKA Gage perpendicular to manual operator PRP1A-GABA PRP1A-GCBA PRP1A-GBBA PRP1A-GDBA PRP1A-GECA PRA01A Gage parallel to manual operator PRP1A-GADA PRP1A-GCDA PRP1A-GBDA PRP1A-GDDA PRP1A-GEEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR (CODED FOR KNOB ADJUSTMENT) Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRP1A-HAKA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRP1A-HCKA Dual pressure Regulator 14 end Regulated pressure to port 4 PRP1A-HBKA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A-HDKA PRP1A-HEKA PRA1A PRP1A Gage perpendicular to manual operator Gage parallel to manual operator * For use with dual pressure valves. Note: Regulating range for above models is 0-10 PSI. For other ranges see technical data page. ADJUSTMENT OPTIONS PRP1A-XXXX PRP1A-HABA PRP1A-HADA PRP1A-HCBA PRP1A-HCDA A for slotted stem adjustment (internal pilot) B for slotted stem adjustment (external/remote air) K for slotted stem with locknut (internal pilot) L for slotted stem with locknut (external/remote air) Notes: 1. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure.. Cannot field convert from internal pilot to external pilot. 4. Wired for double solenoid valves. PRP1A-HBBA PRP1A-HBDA PRP1A-HDBA PRP1A-HDDA PRP1A-HECA PRP1A-HEEA 79 Consult Precautions page 7 before use, installation or service of MAC Valves.. PRAD PRPB PRAC PRPB

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRP1A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 10 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.1 C v Spare parts : Pressure regulator (less sandwich block) : PRP1A-J0KA (knob), PRP1A-C0KA (slotted stem) PRP1A-M0KA (slotted stem with locknut) Regulating range options : PRP1A-XXXA Replace by B Replace by C Replace by D Replace by E Replace by F Replace by G Replace by H Replace by J - 0 to 80 PSI - 0 to 0 PSI - 0 to 10 PSI on 14 end - 0 to 80 PSI on 1 end - 0 to 10 PSI on 1 end - 0 to 80 PSI on 14 end - 0 to 10 PSI on 14 end - 0 to 0 PSI on 1 end - 0 to 10 PSI on 1 end - 0 to 0 PSI on 14 end - 0 to 80 PSI on 14 end - 0 to 0 PSI on 1 end - 0 to 80 PSI on 1 end - 0 to 0 PSI on 14 end DIMENSIONS Dimensions shown are metric (mm) 14.7 14.7 180.4 1 COND 5 97. 80 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRP1A Series Plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A Gage port only PRP1A-DAKA PRP1A-DCKA PRP1A-DBKA PRP1A-DDKA PRP1A-DEKA Gage perpendicular to manual operator PRP1A-DABA PRP1A-DCBA PRP1A-DBBA PRP1A-DDBA PRP1A-DECA PRA01A Gage parallel to manual operator PRP1A-DADA PRP1A-DCDA PRP1A-DBDA PRP1A-DDDA PRP1A-DEEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR Gage Gage port only Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRP1A-EAKA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRP1A-ECKA Dual pressure Regulator 14 end Regulated pressure to port 4 PRP1A-EBKA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A-EDKA PRP1A-EEKA PRA1A PRP1A Gage perpendicular to manual operator Gage parallel to manual operator PRP1A-EABA PRP1A-EADA PRP1A-ECBA PRP1A-ECDA * - To be used with dual pressure valves. Notes: 1. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure.. Cannot field convert from internal pilot to external pilot. 4. Wired for double solenoid valves. PRP1A-EBBA PRP1A-EBDA PRP1A-EDBA PRP1A-EDDA PRP1A-EECA PRP1A-EEEA PRAD PRPB PRAC PRPB 81 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRP1A TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.1 C v Spare parts : Pressure regulator (less sandwich block): PRP1A-F0KA Regulator block to base mounting tie rod: 19496 DIMENSIONS 69. APPROX. WITH DOUBLE REGULATOR SINGLE AND DOUBLE SOLENOIDS 18.1 SINGLE AND DOUBLE SOLENOIDS SINGLE REGULATOR 1 END Dimensions shown are metric (mm) 1 COND 5 11. SINGLE REGULATOR 14 END SINGLE AND DOUBLE SOLENOIDS 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRAD Series Non plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRAD-1AAA PRAD-1EAA PRAD-1BAA PRAD-1FAA PRAD-1JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAD-1ADA PRAD-1CDA PRAD-1EDA PRAD-1GDA PRAD-1BDA PRAD-1DDA PRAD-1FDA PRAD-1HDA PRAD-1JEA ----- PRA01A Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator EXTERNAL PILOT AND REMOTE AIR PRAD-1ABA PRAD-1CBA PRAD-1EBA PRAD-1GBA PRAD-1BBA PRAD-1DBA PRAD-1FBA PRAD-1HBA PRAD-1JCA ----- PRA0A PRA1A Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A No gage PRAD-AAA PRAD-EAA PRAD-BAA PRAD-FAA PRAD-JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAD-ADA PRAD-CDA PRAD-EDA PRAD-GDA PRAD-BDA PRAD-DDA PRAD-FDA PRAD-HDA PRAD-JEA ----- PRAD Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator PRAD-ABA PRAD-CBA PRAD-EBA PRAD-GBA PRAD-BBA PRAD-DBA PRAD-FBA PRAD-HBA PRAD-JCA ----- PRPB * - To be used with dual pressure valves. Note : regulating range for above models is 0-150 PSI. For other ranges see technical data page. ADJUSTMENT OPTIONS PRAD-XXXX A B D E for slotted stem adjustment (internal pilot) for slotted stem adjustment (external pilot) for slotted stem with locknut (internal pilot) for slotted stem with locknut (external pilot) Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #19177. 8 Consult Precautions page 7 before use, installation or service of MAC Valves.. PRAC PRPB

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRAD TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C). C v Spare parts : Regulating range options : PRAD-XXXA Pressure regulator (less sandwich block) : PRAD-0AA (KNOB), PRAD-C0AA (SLOTTED STEM), PRAD-F0AA (SLOTTED STEM WITH LOCKNUT). Gage : Glycerine filled : N-6015-01 Non filled : N-6016-01 Replace by B Replace by C - 0 to 100 PSI - 0 to 45 PSI DIMENSIONS Dimensions shown are metric (mm) SINGLE AND DOUBLE SOLENOIDS REGULATOR "14" END 5.4 186.1 1 COND 5 SINGLE AND DOUBLE SOLENOIDS REGULATORS "14" & "1" ENDS 7.9 7.5 SINGLE AND DOUBLE SOLENOIDS REGULATOR "1" END 84 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRAD Series Non plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRAD-4AAA PRAD-4EAA PRAD-4BAA PRAD-4FAA PRAD-4JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAD-4ADA PRAD-4CDA PRAD-4EDA PRAD-4GDA PRAD-4BDA PRAD-4DDA PRAD-4FDA PRAD-4HDA PRAD-4JEA ----- PRA01A Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator EXTERNAL PILOT AND REMOTE AIR PRAD-4ABA PRAD-4CBA PRAD-4EBA PRAD-4GBA PRAD-4BBA PRAD-4DBA PRAD-4FBA PRAD-4HBA PRAD-4JCA ----- PRA0A PRA1A Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A No gage PRAD-5AAA PRAD-5EAA PRAD-5BAA PRAD-5FAA PRAD-5JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAD-5ADA PRAD-5CDA PRAD-5EDA PRAD-5GDA PRAD-5BDA PRAD-5DDA PRAD-5FDA PRAD-5HDA PRAD-5JEA ----- PRAD Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator PRAD-5ABA PRAD-5CBA PRAD-5EBA PRAD-5GBA PRAD-5BBA PRAD-5DBA PRAD-5FBA PRAD-5HBA PRAD-5JCA ----- PRPB * - To be used with dual pressure valves. Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #19177. PRAC PRPB 85 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRAD TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C). C v Spare parts : Pressure regulator (less sandwich block) : PRAD-60AA. Gage : Glycerine filled : N-6015-01 Non filled : N-6016-01 DIMENSIONS Dimensions shown are metric (mm) 11.1 APPROX. REGULATOR "14" END SINGLE AND DOUBLE SOLENOID 05.8 APPROX. REGULATOR "1" END SINGLE AND DOUBLE SOLENOIDS 187.1 86 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRPB Series Plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER REGULATORS FOR INTERNAL PILOT (CODED FOR KNOB ADJUSTMENT) Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9C PR9A No gage PRPB-AAAA PRPB-AEAA PRPB-ABAA PRPB-AFAA PRPB-AJAA Glycerine gage PRPB-AABA PRPB-AEBA PRPB-ABBA PRPB-AFBA PRPB-AJCA PRA01A Non-filled gage PRPB-AADA PRPB-AEDA PRPB-ABDA PRPB-AFDA PRPB-AJEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR (CODED FOR KNOB ADJUSTMENT) Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRPB-BAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRPB-BEAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRPB-BBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRPB-BFAA PRPB-BJAA PRA1A PRP1A Glycerine gage PRPB-BABA PRPB-BEBA PRPB-BBBA PRPB-BFBA PRPB-BJCA PRAD Non-filled gage * For use with dual pressure valves. Note: Regulating range for above models is 0-150 PSI. For other ranges, see technical data page. ADJUSTMENT OPTIONS PRPB-XXXX PRPB-BADA PRPB-BEDA G for slotted stem (internal pilot) H for slotted stem (external pilot) K for slotted stem with locknut (internal pilot) L for slotted stem with locknut (external pilot) Notes: 1. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure.. Cannot field convert from internal pilot to external pilot. 4. Wired for double solenoid valves. PRPB-BBDA PRPB-BFDA PRPB-BJEA 87 Consult Precautions page 7 before use, installation or service of MAC Valves.. PRPB PRAC PRPB

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRPB TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).1 C v Spare parts : Pressure regulator (less sandwich block) : PRPB-C0AA (knob), PRPB-J0AA (slotted stem), PRPB-M0AA (slotted stem with locknut) Regulator block to base mounting screw: 19177 Regulating range option: PRPB-xxxA Replace by B for 0 to 100 PSI Replace by C for 0 to 45 PSI DIMENSIONS Dimensions shown are metric (mm) 76.9 186.1 1 COND 5 99. 88.9 88 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRPB Series Plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRPB-DAAA PRPB-DEAA PRPB-DBAA PRPB-DFAA PRPB-DJAA Glycerine gage PRPB-DABA PRPB-DEBA PRPB-DBBA PRPB-DFBA PRPB-DJCA PRA01A Non-filled gage PRPB-DADA PRPB-DEDA PRPB-DBDA PRPB-DFDA PRPB-DJEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRPB-EAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRPB-EEAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRPB-EBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRPB-EFAA PRPB-EJAA PRA1A PRP1A Glycerine gage PRPB-EABA PRPB-EEBA PRPB-EBBA PRPB-EFBA PRPB-EJCA PRAD Non-filled gage PRPB-EADA PRPB-EEDA PRPB-EBDA PRPB-EFDA PRPB-EJEA * - To be used with dual pressure valves. Notes: 1. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure.. Cannot field convert from internal pilot to external pilot. 4. Wired for double solenoid valves. PRPB PRAC PRPB 89 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRPB TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C).1 C v Spare parts : Pressure regulator (less sandwich block): PRPB-F0AA Body/block to base mounting screw: 19177 DIMENSIONS Dimensions shown are metric (mm) 5.9 186.1 1 COND 5 05.9 90 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRAC Series Non plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRAC-1AAA PRAC-1EAA PRAC-1BAA PRAC-1FAA PRAC-1JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAC-1ADA PRAC-1CDA PRAC-1EDA PRAC-1GDA PRAC-1BDA PRAC-1DDA PRAC-1FDA PRAC-1HDA PRAC-1JEA ----- PRA01A Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator EXTERNAL PILOT AND REMOTE AIR PRAC-1ABA PRAC-1CBA PRAC-1EBA PRAC-1GBA PRAC-1BBA PRAC-1DBA PRAC-1FBA PRAC-1HBA PRAC-1JCA ----- PRA0A PRA1A Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A No gage PRAC-AAA PRAC-EAA PRAC-BAA PRAC-FAA PRAC-JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAC-ADA PRAC-CDA PRAC-EDA PRAC-GDA PRAC-BDA PRAC-DDA PRAC-FDA PRAC-HDA PRAC-JEA ----- PRAD Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator PRAC-ABA PRAC-CBA PRAC-EBA PRAC-GBA PRAC-BBA PRAC-DBA PRAC-FBA PRAC-HBA PRAC-JCA ----- PRPB * - To be used with dual pressure valves. Note : regulating range for above models is 0-150 PSI. For other ranges see technical data page. ADJUSTMENT OPTIONS PRAC-XXXX A B D E for slotted stem adjustment (internal pilot) for slotted stem adjustment (external pilot) for slotted stem with locknut (internal pilot) for slotted stem with locknut (external pilot) Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #5418. 91 Consult Precautions page 7 before use, installation or service of MAC Valves.. PRAC PRPB

7 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRAC TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.4 C v Spare parts : Pressure regulator (less sandwich block) : PRAC-0AA (KNOB), PRAC-C0AA (SLOTTED STEM), PRAC-F0AA (SLOTTED STEM WITH LOCKNUT). Gage : Glycerine filled : N-6015-01 Non filled : N-6016-01 Regulating range options : PRAC-XXXA Replace by B Replace by C - 0 to 100 PSI - 0 to 45 PSI DIMENSIONS Dimensions shown are metric (mm) 40.1 APPROX. WITH REGOLATOR '1' END WIXOM,MI. USA MODIF. LIEGE,BELGIUM AUCKLAND,N.Z. MODEL ELECTRICAL WATTS VAC TO 10 PSI 4.0 1 5 COND 4. APPROX. WITH REGULATOR '14' END 78.0 4. APPROX. WITH DOUBLE REGULATOR 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRAC Series Non plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators.. Allows to have compact, all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRAC-4AAA PRAC-4EAA PRAC-4BAA PRAC-4FAA PRAC-4JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAC-4ADA PRAC-4CDA PRAC-4EDA PRAC-4GDA PRAC-4BDA PRAC-4DDA PRAC-4FDA PRAC-4HDA PRAC-4JEA ----- PRA01A Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator EXTERNAL PILOT AND REMOTE AIR PRAC-4ABA PRAC-4CBA PRAC-4EBA PRAC-4GBA PRAC-4BBA PRAC-4DBA PRAC-4FBA PRAC-4HBA PRAC-4JCA ----- PRA0A PRA1A Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRP1A No gage PRAC-5AAA PRAC-5EAA PRAC-5BAA PRAC-5FAA PRAC-5JAA Non-filled gage on regulator(s) Non-filled gage opposite to regulator PRAC-5ADA PRAC-5CDA PRAC-5EDA PRAC-5GDA PRAC-5BDA PRAC-5DDA PRAC-5FDA PRAC-5HDA PRAC-5JEA ----- PRAD Glycerine filled gage on regulator(s) Glycerine filled gage opposite to regulator PRAC-5ABA PRAC-5CBA PRAC-5EBA PRAC-5GBA PRAC-5BBA PRAC-5DBA PRAC-5FBA PRAC-5HBA PRAC-5JCA ----- PRPB * - To be used with dual pressure valves. Main valve body assembly must be external pilot model. Pilots are supplied internally from primary pressure in regulator block. Cannot field convert regulator block from Single Pressure to dual pressure. Body/Block to base mounting screw #5418. PRAC PRPB 9 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRAC TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.4 C v Spare parts : Pressure regulator (less sandwich block) : PRAC-60AA. Gage : Glycerine filled : N-6015-01 Non filled : N-6016-01 DIMENSIONS 51. MANIFOLD & INDIVIDUAL BASE WITH DOUBLE REGULATOR Dimensions shown are metric (mm) 74.8 INDIVIDUAL BASE WITH REGULATOR "1" END 74.8 INDIVIDUAL BASE WITH REGULATOR "14" END 1.0 94 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRPB Series Plug-in sandwich pressure regulator with manual adjust knob OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER REGULATORS FOR INTERNAL PILOT (CODED FOR KNOB ADJUSTMENT) Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9C PR9A No gage PRPB-AAAA PRPB-AEAA PRPB-ABAA PRPB-AFAA PRPB-AJAA Glycerine gage PRPB-AABA PRPB-AEBA PRPB-ABBA PRPB-AFBA PRPB-AJCA PRA01A Non-filled gage PRPB-AADA PRPB-AEDA PRPB-ABDA PRPB-AFDA PRPB-AJEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR (CODED FOR KNOB ADJUSTMENT) Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRPB-BAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRPB-BEAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRPB-BBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRPB-BFAA PRPB-BJAA PRA1A PRP1A Glycerine gage PRPB-BABA PRPB-BEBA PRPB-BBBA PRPB-BFBA PRPB-BJCA PRAD Non-filled gage PRPB-BADA PRPB-BEDA PRPB-BBDA PRPB-BFDA PRPB-BJEA * For use with dual pressure valves. PRPB ADJUSTMENT OPTIONS PRPB-XXXX G H K L for slotted stem (internal pilot) for slotted stem (external pilot) for slotted stem with locknut (internal pilot) for slotted stem with locknut (external pilot) Notes: 1. Regulating range for above models is 0-150 PSI. For other ranges, see technical data page.. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure. 4. Cannot field convert from internal pilot to external pilot. 5. Wired for double solenoid valves. PRAC PRPB 95 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRPB TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI (other ranges see below) Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.4 C v Spare parts : Pressure regulator (less sandwich block): PRPB-C0AA (knob), PRPB-J0AA (slotted stem), PRPB-M0AA (slotted stem with locknut) Regulating block to base mounting screw: 19457 Regulating range options: PRPB-xxxA Replace by B for 0 to 100 PSI Replace by C for 0 to 45 PSI DIMENSIONS 51. MANIFOLD & INDIVIDUAL BASE WITH DOUBLE REGULATOR Dimensions shown are metric (mm) 74.8 INDIVIDUAL BASE WITH REGULATOR "1" END 74.8 INDIVIDUAL BASE WITH REGULATOR "14" END 1.0 96 Consult Precautions page 7 before use, installation or service of MAC Valves..

P r e s s u r e r e g u l a t o r s Series PRPB Series Plug-in sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators.. Compact all-included units.. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. PR7A PR4B PR46A PR47A PR48B HOW TO ORDER PR9C REGULATORS FOR INTERNAL PILOT Gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 Single pressure Regulator 1 end Same regulated pressure to ports and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PR9A No gage PRPB-DAAA PRPB-DEAA PRPB-DBAA PRPB-DFAA PRPB-DJAA Glycerine gage PRPB-DABA PRPB-DEBA PRPB-DBBA PRPB-DFBA PRPB-DJCA PRA01A Non-filled gage PRPB-DADA PRPB-DEDA PRPB-DBDA PRPB-DFDA PRPB-DJEA PRA0A REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR Gage No gage Single pressure Regulator 14 end Same regulated pressure to ports and 4 PRPB-EAAA Single pressure Regulator 1 end Same regulated pressure to ports and 4 PRPB-EEAA Dual pressure Regulator 14 end Regulated pressure to port 4 PRPB-EBAA * Dual pressure Regulator 1 end * Dual pressure Dual regulator * Regulated pressure to port Two regulated pressures to ports and 4 PRPB-EFAA PRPB-EJAA PRA1A PRP1A Glycerine gage PRPB-EABA PRPB-EEBA PRPB-EBBA PRPB-EFBA PRPB-EJCA PRAD Non-filled gage PRPB-EADA PRPB-EEDA PRPB-EBDA PRPB-EFDA PRPB-EJEA * - To be used with dual pressure valves. Notes: 1. Valves used with above models must be external pilot models.. Cannot field convert regulator block from single pressure to dual pressure.. Cannot field convert from internal pilot to external pilot. 4. Wired for double solenoid valves. PRPB PRAC PRPB 97 Consult Precautions page 7 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRPB TECHNICAL DATA Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow : Compressed air, inert gases 0 to 150 PSI 0 to 150 PSI Not required, if used select a medium aniline point lubricant (between 180 F to 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 5.4 C v Spare parts : Pressure regulator (less sandwich block): PRPB-F0AA Regulator block to base mounting screw: 19457 DIMENSIONS 51. MANIFOLD & INDIVIDUAL BASE WITH DOUBLE REGULATOR Dimensions shown are metric (mm) 74.8 INDIVIDUAL BASE WITH REGULATOR "1" END 74.8 INDIVIDUAL BASE WITH REGULATOR "14" END 1.0 98 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section 5 Intrinsically Safe Valves 99 Consult Precautions page 7 before use, installation or service of MAC Valves..

Page Specifications for Intrinsically Safe Valves 01 5 series 04 400 series 04 9 series 05 00 Consult Precautions page 7 before use, installation or service of MAC Valves..

I n t r i n s i c a l l y S a f e V a l v e s INTRINSICALLY SAFE CIRCUIT In order to use an intrinsically safe valve in a hazardous location, the installation must be in accordance with the following installation diagram : MAC Valve Approved for Class I, II, & III Division 1 Group A, B, C, D, E, F & G Vmax = 0 v Imax = 175 ma Ci = 0 Li = 0 + Red - Black Associated Apparatus FMRC Approved Single or Dual Channel Positive Polarity Intrinsic Safety Barriers Control Room Equipment Hazardous Location Non-Hazardous Location Class I, II & III Division 1 Group A, B, C, D, E, F & G There are basic parts to an intrinsically safe circuit : 1. FIELD DEVICE This is defined as the device that will be used in the hazardous location. In this case, the field device will be the intrinsically safe valve.. ASSOCIATED APPARATUS This will be an energy limiting device also known as a barrier.. FIELD WIRING Wiring used to connect the two above devices. When the MAC intrinsically safe valves were tested for approval, they were tested and approved for the following atmospheres. Class I, II, III Division 1 Groups ; A, B, C, D, E, F, G under the following parameters : Vmax : 0 VDC Imax : 175 ma Ci : 0 Li : 0 01 Consult Precautions page 7 before use, installation or service of MAC Valves..

I n t r i n s i c a l l y S a f e V a l v e s What this means is that the intrinsically safe valves were tested against each atmosphere with up to 0 VDC and 175 ma of current across the solenoid and found to still be safe. The other two parameters are values to indicate how much energy can be stored or created by the valve : Ci : Internal capacitance of the solenoid. This indicates how much energy the solenoid is capable of storing. Li : Internal inductance of the solenoid. This indicates the solenoid s ability to create or increase energy beyond what is supplied. When applying an intrinsically safe valve in a hazardous location, a proper barrier must first be selected. The barrier selection process must first take into account the parameters the valve was approved for and compared in the following way : Vmax must be greater than or equal to Voc of the barrier. Voc = Voltage open circuit or maximum allowed out of the barrier Imax must be greater than or equal to Isc of the barrier. Isc = Current short circuit or the maximum current allowed out of the barrier Ci plus field wiring must be less than Ca of the barrier. Ca = Allowed capacitance Li plus field wiring must be less than La of the barrier. La = Allowed inductance When properly combined, the barrier will never allow more energy to the intrinsically safe valve than what it was tested and approved for. The following page can be used as your guide to help ask the right questions when working with an intrinsically safe circuit. Also included is a partial list of intrinsically safe barriers that have been tested with the MAC intrinsically safe valves. 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

I n t r i n s i c a l l y S a f e V a l v e s Approval : Factory Mutual Research X7A8.AX (610) Approved as intrinsically safe apparatus and associated apparatus for use in Class I, II, III - Division 1, Group : A, B, C, D, E, F & G. Parameters : Vmax : 0 VDC Imax : 175 ma Ci : 0 Li : 0 Operating voltage greater than 11.5 volts Coil resistance : Approximately 50 ohms Current draw : 50 ma Wattage : 0.6 watts Circuit Check Lists : Is Vmax greater than or equal to Voc? Is Imax greater than or equal to Isc? Is Ci less than Ca? Is Li less than La? Is the barrier capable of handing 50 ma draw? Is the internal resistance of the barrier 50 ohms or less? If all answers to the above questions are yes the barrier may be a good choice in combination with the MAC intrinsically safe valve. To calculate voltage across the solenoid, plug values into the following equations : ITOTAL = SUPPLY VOLTAGE ITOTAL = = Plug ITOTAL in below Plug ITOTAL in below 50 + BARRIER RESISTANCE Voltage at Solenoid = I TOTAL x 50 ohms = volts Voltage Voltage Manufacturer Model # Barrier Res. w/o Light w/light Groups Type Turck MK7-S01-EX 11. v 10. v* A-G T.I.B. Crouse-Hinds SB19140-M410 1. v 1.6 v C-G Zener IMO Industries (Gems Sensors) 11407 4 OHMS 1.0 v 11.4 v C-G Zener Pepperl & Fuchs KHZ-9/EX-1 70 OHMS 11.6 v 11.06 v A-G Zener KHZ-9/EX- 70 OHMS 11.6 v 11.06 v A-G Zener KHZ-9/EX- 70 OHMS 11.6 v 11.06 v A-G Zener Stahl 9001/01-80-165-10 1.5 v 1.9 v C-G Zener 951/10-14-10 80 OHMS 1.7 v 1.4 v A-G T.I.B. Ronan X57-9P 00 OHMS 1.7 v 1.05 v C-G Zener Measurement Technology MTL78P+ 50 OHMS 11.9 v 11.4 v A-G Zener MTL0 15.0 v 14.5 v C-G T.I.B. Above data is based on a 4 v DC supply voltage to the input of the barrier. A 1 v DC, 4 OHM,.6 watt intrinsically safe solenoid is used. The measurement with light is an LED with a current limiting resistor. Groups indicate what atmosphere the barrier has been approved for. All MAC intrinsically safe valves have been approved for Class I, II and III, Division 1, Groups A, B, C, D, E, F and G indoor hazardous locations. T.I.B. = Transformer Isolated Barrier * = Not a recommended combination 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

I n t r i n s i c a l l y S a f e V a l v e s Series 5-400 HOW TO ORDER BODY OPTIONS BASE OPTIONS PILOT VALVE 5A - XX - XXX - (XX - DXXX - XXX) SEE BELOW SPOOL TYPE BODY OPTIONS PORT SIZE - THREAD TYPE INT. OR EXT. PILOT 1 Single Operator N.C. Main Double Operator N.C. Main Single Operator N.O. Main 4 Double Operator N.O. Main 1 Inline port Manifold body 4 Inline port with memory spring 6 Manifold body with memory spring 0 Manifold body A 1/8 NPTF B 1/4 NPTF C 1/8 BSPPL D 1/4 BSPPL E 1/8 BSPTR F 1/4 BSPTR A B C Internal Pilot External Pilot-For inline bodies only Common External Pilot for manifold bodies only BASE CONFIGURATION 0 Inline/Manifold Body 4XXA - XXX - XX - DXXX - XXX PILOT VALVE SEE BELOW REVISION LEVEL SPOOL TYPE BODY OPTIONS PORT SIZE - THREAD TYPE INT. OR EXT. PILOT 0 Base only 1 Single Operator-Single Pressure Double Operator-Single Pressure Single Operator-Dual Pressure 4 Double Operator -Dual Pressure 5 Position Closed Center 6 Position Open Center 7 Position Single Pressure Pressure Center 0 Base only 1 Inline 5 port Manifold body (base mount body) 4 Inline 5 port with memory* 6 Manifold body with memory* 0 Manifold body A 1/8 NPTF B 1/4 NPTF C 1/8 BSPPL D 1/4 BSPPL E 1/8 BSPTR F 1/4 BSPTR A B C D Internal Pilot (on dual press. models pilot pressure is from port #5 External Pilot (inline body) Internal Pilot (on dual press. models pilot pressure is from port # External & common external pilot (individual base & bar manifold) *Does not apply to positions valves **Accepts manifold body only SOLENOID PILOT VALVE OPTIONS XX - DXXX - XXX BASE CONFIGURATION 0 Inline/Manifold Body A Base standard ports** B Base standard ports with flow controls** XX PILOT EXHAUST XX DC VOLTAGE DM Muffled exhaust FR 1 VDC (0.6 W) *Use this lead wire length for plug-in connectors. X A 18 B 4 C 6 D 48 E 7 F 96 J 6 * LEAD WIRE LENGTH X MANUAL OPERATOR 0 No operator 1 Non-locking Recessed (std.) Locking Recessed Non-locking Extended 4 Locking Extended XX ELECTRICAL CONN. BA Grommet CA Conduit 1/" NPS CM Metal Conduit 1/" NPS CN Metal Conduit with ground1/" NPS --External Plug-in-- JB Rectangular plug-in JM Rectangular male only KA Mini plug-in KJ Mini plug-in male only TA Dual tabs (.110) w/receptables TD Dual tabs w/light w/receptables TJ Dual tabs (.110) plain TM Dual tabs w/light without receptables 04 Consult Precautions page 7 before use, installation or service of MAC Valves..

I n t r i n s i c a l l y S a f e V a l v e s Series 9 HOW TO ORDER BODY OPTIONS BASE OPTIONS PILOT VALVE 9B - XXX - XXX - (XX - DXXX - XXX) SEE BELOW VALVE FUNCTION BODY ELECTRICAL OPTIONS PORT SIZE - THREAD TYPE INT. OR EXT. PILOT 0 Base only A Single Operator-Single Pressure B Double Operator-Single Pressure C Single Operator-Dual Pressure D Double Operator -Dual Pressure E Position Closed Center F Position Open Center G Position Single Pressure Pressure Center Spool with Memory Spring L Single Operator-Single Pressure N Single Operator-Dual Pressure 0 Base only A No ligth in top B With ligth 0 Basic Valve A 1/8 NPTF B 1/4 NPTF C /8 NPTF D 1/8 BSPPL E 1/4 BSPPL F /8 BSPPL G 1/8 BSPTR H 1/4 BSPTR J /8 BSPTR 0 Basic Valve Plug-in Internal Pilot Models A No light in base B With single light in base C With double light in base Plug-in External Pilot Models D No light in base E With single light in base F With double light in base Non plug-in G Internal Pilot H External Pilot If lights are in top body cover, use option A or D BODY TYPE & EXHAUST OPTIONS 0 Base only A Plug-in Standard Exhaust B* Non Plug-in with Standard Exhaust * Use with body electrical option A only PILOT VALVE OPTIONS XX - DXXX - XXX INDIV. BASE CONFIG. 0 Basic Valve A Side Ports B Bottom Ports (1/8 only) C Side & Bottom Ports (1/8 only) D Side in & exhaust Bottom cylinders (1/8 only) XX PILOT EXHAUST DM Muffled exhaust XX DC VOLTAGE FR 1 VDC (0.6 W) X LEAD WIRE LENGTH --Plug-in Valve/Base-- P Plug-in 1 18 4 48 4 5 7 6 6 96 --Non Plug-in Valve/Base-- O No wires* A 18 E 7 B 4 F 96 C 6 J 6 ** D 48 *Used only with BM & BG electrical connection ** Lead wire length for external plug-in connectors must be J X MANUAL OPERATOR 0 No manual operator 1 Recessed Non-locking operator Recessed Locking operator Non-locking Extended operator 4 Locking Extended operator XX ELECTRICAL CONN. --Non Plug-in Valve/Base-- BA Grommet BM Flying leads BG Flying leads with ground CA Conduit 1/" NPS CM Metal Conduit 1/" NPS CN Metal Conduit with ground1/" NPS --Plug-in Valve/Base-- DM Plug-in DG Plug-in with ground --External Plug-in-- JB Rectangular plug-in JM Rectangular male only KA Mini plug-in KJ Mini plug-in male only HOW TO ORDER 9 SERIES FLOW CONTROL MODULE* FC 9C-AA FC 9C-BA FC 9C-CA Plug-in flow control assembly single solenoid Plug-in flow control assembly double solenoid Non plug-in flow control assembly *If flow control module is to be installed between valve and base or valve and manifold at the factory, add -9 after the flow control model number, i.e., FC9C-AA-9. The flow control model number should follow the valve model number on which it is to be installed. NOTE: If a flow control assembly is used with the dual pressure regulator option, only the flow control on the B end is functional. (Controls both cylinder ports.) NOTE: Consult the general catalog for regulator and circuit bar ordering information. 05 Consult Precautions page 7 before use, installation or service of MAC Valves..

Section 6 Options 07 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX 1 4 - Pilot operated valves 5, 67, 9, 9, 400, ISO1, ISO, ISO Series OPTIONS AVAILABLE FOR 09 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE D-XX X-X XX VOLTAGE DA 4 VDC (5.4W) DB 1 VDC (5.4W) DC 1 VDC (7.5W) DD 4 VDC (7.W) DE 1 VDC (1.7W) DF 4 VDC (1.7W) DK 110 VDC (4.7W) DJ 8 VDC (5.W) DL 64 VDC (6.0W) DM 6 VDC (5.W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 110 VDC (7.W) DT 75 VDC (5.6W) DP 48 VDC (5.8W) FA 1 VDC (1.8W) FB 4 VDC (1.8W) FE 1 VDC (.4W) FF 4 VDC (.4W) JA 10/60, 110/50 (.9W) JB 40/60, 0/50 (.9W) JC 4/60, 4/50 (.7W) JD 100/60, 100/50, 110/60 (.9W) JE 0/60 (.4W) JF 40/50 (.8W) JG 00/60, 00/50 (.9W). WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 18" B 4" C 6" D 48" E 7" F 96" 4. ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* 1/" NPS conduit with flying leads CM* 1/" NPS metal conduit with flying leads CN* 1/" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 0 volts, a ground wire is required. Applies to options with flying leads.. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed Locking recessed Non-locking extended 4 Locking extended 10 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE G XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves, 4, 8, 4, 44 & 48 Series 11 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE G-XX X-X XX VOLTAGE AA 10 VAC (.5W) Requires electrical connector with rectifier AC 4 VAC (4.0W) Requires electrical connector with rectifier DA 4 VDC (1.0W) DC 4 VDC (1.8W) DD 4 VDC (.5W) DE 4 VDC (.0W) DF 4 VDC (4.0W) DG 1 VDC (1.0W) DJ 1 VDC (1.8W) DK 1 VDC (.5W) DM 1 VDC (.0W) DN 1 VDC (4.0W) DR 6 VDC (1.8W) DS 6 VDC (.0W) EB 48 VDC (1.8W) EC 48 VDC (.0W) ED 10 VDC (.5W) GD 1 VDC (0.5W) 4 series only GE 4 VDC (0.5W) 4 series only. WIRE LENGTH G-XX X-X XX WIRE LENGTH 0 No lead wires (used only with "KJ" & "KM" connectors) A 18" coil leads B 4" coil leads C 6" coil leads D 48" coil leads E 7" coil leads F 96" coil leads G 10" coil leads H 144" coil leads 1 18" base leads 4" base leads 6" base leads 4 48" base leads 5 7" base leads 6 96" base leads 7 10" base leads. MANUAL OPERATOR G-XX X-X XX MANUAL OPERATOR 1 Non-locking recessed Locking recessed Non-locking extended 4 Locking extended G-XX X-X XX BA BB BC BD BE BF BG BH BN BP BR BS GA GB GC GD GE GF GG GH KA KB KC KD KE KF KJ KM KN KP KT KU KV KW KX KY G-XX X-X XX SB SC SD SE SF SG SH SK SL SM 4. ELECTRICAL CONNECTION ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light BA with light and ground wire BA with suppression diode BA with suppression diode and ground wire BA with suppression diode and light BA with suppression diode, light and ground wire BA with suppression diode and blocking diode BA with suppression diode, blocking diode and ground wire BA with suppresion diode, blocking diode and light BA with suppression diode, blocking diode, light and ground wire MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Solenoid plug-in wire assembly KA with ground KA with rectifier and light KA with rectifier, light and ground KA with suppression diode KA with suppression diode and ground Solenoid plug-in housing without wire assembly Solenoid plug-in housing with ground pin without wire assembly KA with suppression diode and blocking diode KA with suppression diode, blocking diode and ground KA with light KA with light and ground KA with suppression diode and light KA with suppression diode, light and ground KA with suppression diode, blocking diode and light KA with suppression diode, blocking diode, light & ground ELECTRICAL CONNECTION FOR PLUG-IN VALVES SN SP SR PLUG-IN OPTIONS Base plug-in with ground Base plug-in with suppression and blocking diode Base plug-in with suppression and blocking diode and ground Base plug-in with MOV Base plug-in with MOV and ground Base plug-in with rectifier Base plug-in with rectifier and ground Base plug-in with light and ground Base plug-in with suppression and blocking diode and light Base plug-in with suppression and blocking diode with light and ground Base plug-in with MOV and light Base plug-in with MOV and light with ground Base plug-in with rectifier and light 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE -GM- G XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves 5 & 400 Series 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE 4. ELECTRICAL CONNECTION G-XX X-X XX VOLTAGE DC 4 VDC (1.8 W) DD 4 VDC (.5 W) DE 4 VDC (.0 W) DF 4 VDC (4.0 W) DJ 1 VDC (1.8 W) DK 1 VDC (.5 W) DM 1 VDC (.0 W) DN 1 VDC (4.0 W) G-XX X-X XX. WIRE LENGTH WIRE LENGTH 0 No lead wire (use only with "KJ" & "KM" elecrical connectors) A 18" B 4" C 6" D 48" E 7" F 96" G 10" H 144". MANUAL OPERATOR G-XX X-X XX BA BB BC BD BE BF BG BH *BN *BP *BR *BS BT BU BV BW *BX *BY ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light parallel to leads BA with light parallel to leads & ground wire BA with suppression diode BA with suppression diode & ground wire BA with suppression diode plus light parallel to leads BA with suppression diode plus light parallel to leads & ground wire BA with suppression diode plus blocking diode BA with suppression diode plus blocking diode & ground wire BA with suppression diode plus blocking diode & light parallel to leads BA with suppression diode plus blocking diode & light parallel to leads & ground wire BA with light on top BA with light on top & ground wire BA with suppression diode plus light on top BA with suppression diode plus light on top & ground wire BA with suppression diode plus blocking diode & light on top BA with suppression diode plus blocking diode & light on top & ground wire G-XX X-X XX MANUAL OPERATOR 1 Non-locking recessed Locking recessed Non-locking extended 4 Locking extended G-XX X-X XX GA GB GC GD GE GF GG GH KA KB KE KF KJ KM *KN *KP KT KU KV KW *KX *KY SOLENOID PLUG-IN CONNECTOR WITH LEADS MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly KA with ground wire KA with suppression diode KA with suppression diode & ground wire Plug-in housing without wire assembly ('KA' without wire assembly) Plug-in housing without wire assembly ('KB' without wire assembly) KA with suppression diode plus blocking diode KA with suppression diode plus blocking diode & ground wire KA with light on top KA with light on top & ground wire KA with suppression diode plus light on top Note: Blocking diode is located in the lead wire KA with suppression diode plus light & ground wire KA with suppression diode plus blocking diode & light on top KA with suppression diode plus blocking diode & light on top & ground wire 14 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE H XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves 7 & 47 Series 15 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE H-XX X-X XX VOLTAGE AA 10/50, 10/60 (6.7 W) (use connector with rectifier) AB 0/50, 0/60 (5.6 W) (use connector with rectifier) AC 40/50, 40/60 (5.8 W) (use connector with rectifier) AD 4/50, 4/60 (7.8 W) (use connector with rectifier) DA 4 VDC (5. W) DB 4 VDC (.4 W) DC 4 VDC (1.8 W) DD 4 VDC (1.0 W) DF 1 VDC (5. W) DG 1 VDC (.4 W) DH 1 VDC (1.8 W) DJ 1 VDC (1.0 W) DL 10 VDC (6. W) H-XX X-X XX BL BT BU H-XX X-X XX FA FB FC FD FE FF FG FH FK FL *FN *FP *FR *FS BA with full wave rectifier & ground wire BA with full wave rectifier plus light BA with full wave rectifier plus light & ground wire PLUG-IN CONNECTOR Base plug-in FA with ground wire FA with light FA with light & ground wire FA with suppression diode FA with suppression diode & ground wire FA with suppression diode & light FA with suppression diode plus light & ground wire FA with full wave rectifier FA with full wave rectifier & ground wire FA with suppression diode plus blocking diode FA with suppression diode plus blocking diode & ground wire FA with suppression diode plus blocking diode plus light FA with suppression diode plus blocking diode & light & ground wire. WIRE LENGTH H-XX X-X XX WIRE LENGTH 0 No lead wire (use with "MJ, MM & K Type connectors) A 18" B 4" C 6" D 48" E 7" F 96" G 10" H 144". MANUAL OPERATOR H-XX X-X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed Locking recessed Non-locking extended 4 Locking extended H-XX X-X XX BA BB BC BD BE BF BG BH *BN *BP *BR *BS BK 4. ELECTRICAL CONNECTION ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light BA with light & ground wire BA with suppression diode BA with suppression diode & ground wire BA with suppression diode plus light BA with suppression diode plus light & ground wire BA with suppression diode plus blocking diode BA with suppression diode plus blocking diode & ground wire BA with suppression diode plus blocking diode & light BBA with suppression diode plus blocking diode & light & ground wire BA with full wave rectifier FT FU MA MB MC MD ME MF MG MH MK ML *MN *MP *MR *MS FA with full wave rectifier plus light FA with full wave rectifier plus light & ground wire Solenoid plug-in wire assembly MA with ground wire MA with light MA with light & ground wire MA with suppression diode MA with suppression diode & ground wire MA with suppression diode plus light MA with suppression diode plus light & ground wire MA with full wave rectifier MA with full wave rectifier & ground wire MA with suppression diode plus blocking diode MA with suppression diode plus blocking diode & ground wire MA with suppression diode plus blocking diode & light MA with suppression diode plus blocking diode & light & ground wire MT MA with full wave rectifier plus light MU MA with full wave rectifier plus light & ground wire MJ Plug-in housing without wire assembly ('MA' option without wire assembly) MM Plug-in housing without wire assembly ('MB' option without wire assembly) KA Mini square connector KB KA with suppression diode KC KA with M.O.V. KD KA with light KE KA with light & suppression diode KF KA with light & M.O.V. KJ Mini square connector male only KK KJ with suppression diode KL KJ with M.O.V. KM KA with full wave rectifier KN KA with full wave rectifier & M.O.V. KP KA with full wave rectifier & light KR KA with full wave rectifier plus light & M.O.V. KS KJ with full wave rectifier * Blocking diode is located in the lead wire 16 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE J XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves 6, 46, ISO 01 and ISO 0 Series 17 Consult Precautions page 7 before use, installation or service of MAC Valves..

O P TIONS 1. VOLTAGE J-XX X-X XX VOLTAGE AA 10VAC (5.4W) AC 4VAC (5.4W) DE 4VDC (1.8W) DF 1VDC (1.8W) DJ 4VDC (1.W) DL 1VDC (1.W) DR 1VDC (1.0W)* DU 4VDC (1.0W)* * Not available on 6 series universal valve J-XX X-X XX A B C D E F P O. WIRE LENGTH WIRE LENGTH 18" coil leads 4" coil leads 6" coil leads 48" coil leads 7" coil leads 96" coil leads Base plug-in No leads (use with J, K & L type connectors). MANUAL OPERATOR J-XX X-X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed Locking recessed Non-locking extended 4 Locking extended J-XX X-X XX BA GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GR GS *JA *JC *JE *JF *JG *JH *JK 4. ELECTRICAL CONNECTION CONNECTORS FOR NON PLUG-IN VALVES ELECTRICAL CONNECTION Flying leads MAC JAC solenoid plug-in MAC JAC solenoid plug-in with diode MAC JAC solenoid plug-in with MOV MAC JAC solenoid plug-in with light MAC JAC solenoid plug-in with diode and light MAC JAC solenoid plug-in with MOV and light MAC JAC solenoid plug-in with rectifier MAC JAC solenoid plug-in with rectifier and light MAC JAC solenoid plug-in Male only MAC JAC solenoid plug-in with diode Male only MAC JAC solenoid plug-in with MOV Male only MAC JAC solenoid plug-in with light Male only MAC JAC solenoid plug-in with diode and light Male only MAC JAC solenoid plug-in with MOV and light Male only MAC JAC solenoid plug-in with rectifier Male only MAC JAC solenoid plug-in with rectifier and light Male only Square Connector Square Connector with light Square Connector with diode Square Connector with MOV Square Connector with diode/light Square Connector with MOV /light Square Connector with Rectifier J-XX X-X XX *JL Square Connector with Rectifier with light *JJ Square Connector Male only (Plain) *JB Rectangular Connector *JD Rectangular Connector with light *JN Rectangular Connector with diode *JP Rectangular Connector with MOV *JR Rectangular Connector with diode/light *JS Rectangular Connector with MOV /light *JT Rectangular Connector with Rectifier *JU Rectangular Connector with Rectifier with light *JM Rectangular Connector Male only (Plain) * Not available on manifold or stacking valves J-XX X-X XX J-XX X-X XX KA KB KC KD KE KF KG KH KJ KK KL KM KN KP KR KS LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LR LS J-XX X-X XX FA FB FC FD FE FF FG FH CONNECTORS FOR NON PLUG-IN VALVES MINI SQUARE PLUG-IN CONNECTORS 9.4 MM SPACING BETWEEN PINS Mini plug-in Mini plug-in with diode Mini plug-in with MOV Mini plug-in with light Mini plug-in with diode and light Mini plug-in with MOV and light Mini plug-in with rectifier Mini plug-in with rectifier and light Mini plug-in Male only Mini plug-in with diode - Male only Mini plug-in with MOV - Male only Mini plug-in with light - Male only Mini plug-in with diode and light Male only Mini plug-in with MOV and light Male only Mini plug-in with rectifier Male only Mini plug-in with rectifier and light Male only CONNECTORS FOR NON PLUG-IN VALVES MINI SQUARE PLUG-IN CONNECTORS 8.0 MM SPACING BETWEEN PINS ISO SPECIFICATION 1517 Mini plug-in Mini plug-in with diode Mini plug-in with MOV Mini plug-in with light Mini plug-in with diode and light Mini plug-in with MOV and light Mini plug-in with rectifier Mini plug-in with rectifier and light Mini plug-in Male only Mini plug-in with diode - Male only Mini plug-in with MOV - Male only Mini plug-in with light - Male only Mini plug-in with diode and light Male only Mini plug-in with MOV and light Male only Mini plug-in with rectifier Male only Mini plug-in with rectifier and light Male only CONNECTORS FOR PLUG-IN VALVES Base plug-in Base plug-in with diode Base plug-in with MOV Base plug-in with light Base plug-in with diode and light Base plug-in with MOV and light Base plug-in with rectifier Base plug-in with rectifier and light 18 Consult Precautions page 7 before use, installation or service of MAC Va

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE L XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves, 8, 4, 44, 47 & 48 Series 19 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE (, 8, 4, 44, 48 SERIES) 1. VOLTAGE (47 SERIES) L- XX X-X XX VOLTAGE DF 4VDC (4.0W) DN 1VDC (4.0W) HA 4VDC (1.95W) HE 1VDC (1.95W) L- XX X-X XX VOLTAGE DA 4VDC (5.W) DF 1VDC (5.W). WIRE LENGTH (all series) L- XX X-X XX WIRE LENGTH 0 No lead wire A 18" B 4" C 6" D 48" E 7" F 96" G 10" H 144". MANUAL OPERATOR (all series) L- XX X-X XX MANUAL OPERATOR 0 No operator 4. ELECTRICAL CONNECTOR (, 8, 4, 44 & 48 series) 4. ELECTRICAL CONNECTOR (47 series) L-XX X-X XX BA BB BC BD BJ BK BL BM KA KB KC KD KE KF KG KH LA NON PLUG-IN wire flying leads wire flying leads with ground wire wire flying leads with light wire flying leads with light & ground wire 4 wire flying leads 4 wire flying leads with ground 4 wire flying leads with light 4 wire flying leads with light & ground wire wire plug-in assembly wire plug-in assembly with ground wire wire plug-in assembly with light wire plug-in assembly with light and ground wire 4 wire plug-in assembly 4 wire plug-in assembly with ground wire 4 wire plug-in assembly with light 4 wire plug-in assembly and ground wire wire plug-in assembly (polarity switching cover) L-XX X-X XX PLUG-IN *DA Base plug-in *DB Base plug-in with ground pin *DC Base plug-in with light *DD Base plug-in with light & ground pin **EA Base plug-in pin (Plarity switching cover) * Use these options for plug-in base with or 4 wire assemblies ** Use this option for plug-in bases with wire assemblies L- XX X-X XX NON PLUG-IN BA wire flying leads BB wire flying leads with ground wire BC wire flying leads with light BD wire flying leads with light & ground wire BJ 4 wire flying leads BK 4 wire flying leads with ground BL 4 wire flying leads with light BM 4 wire flying leads with light & ground wire LA wire plug-in assembly (Plarity switching cover) MA wire plug-in assembly MB wire plug-in assembly with ground wire MC wire plug-in assembly with light MD wire plug-in assembly with light and ground wire ME 4 wire plug-in assembly MF 4 wire plug-in assembly with ground wire MG 4 wire plug-in assembly with light MH 4 wire plug-in assembly with light and ground wire L- XX X-X XX PLUG-IN EA Base plug-in pin (Polarity switching cover) FA Base plug-in with ground FB Base plug-in with ground & light FC Base plug-in 4 wire with ground FD Base plug-in 4 wire with light & ground 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE R XX X-X XX 1 4 OPTIONS AVAILABLE FOR - Solenoid valves Series 1 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE R-XX X-X XX DA DB DC DD DE DF DG DH DJ DK DL DM EA* EB* EC* VOLTAGE 4 VDC (0.5W) 4 VDC (1.0W) 4 VDC (1.8W) 4 VDC (.5W) 4 VDC (.0W) 4 VDC (4.0W) 1 VDC (0.5W) 1 VDC (1.0W) 1 VDC (1.8W) 1 VDC (.5W) 1 VDC (.0W) 1 VDC (4.0W) 4 VDC (60W) 4 VDC (90W) 4 VDC (0W). WIRE LENGTH (all series) R-XX X-X XX WIRE LENGTH 0** No lead wire A 18" B 4" C 6" D 48" E 7" F 96" G 10" H 144". MANUAL OPERATOR R-XX X-X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed Non-locking extended 4. ELECTRICAL CONNECTOR R-XX X-X XX NON PLUG-IN BA Flying leads BB Flying leads with LED BC Flying leads with MOV BD Flying leads with LED and MOV RA Mini JAC solenoid plug-in RB Mini JAC solenoid plug-in with LED RC Mini JAC solenoid plug-in with MOV RD Mini JAC solenoid plug-in with LED and MOV TA JST solenoid plug-in TB JST solenoid plug-in with LED TC JST solenoid plug-in with MOV TD JST solenoid plug-in with LED and MOV *MOD numbers required for these voltages (consult factory) ** Not available for flying leads connector Consult Precautions page 7 before use, installation or service of MAC Valves..

Section 7 Supplemental technical information Consult Precautions page 7 before use, installation or service of MAC Valves..

Technical Info MAC s PATENDED LATCHING SOLENOID Eliminates one Solenoid, Simplifies Wiring, Reduces Package Size MAC s latching solenoid technology provides the function of a double solenoid operated valve utilizing only one solenoid. Typical position direct operated double solenoid valves use two solenoids with spool/bore technology. When the power is removed from either solenoid, the spool position and valve function is maintained. With direct acting solenoid valves, poppets with their inherent short strokes are not typically used as they cannot maintain sealing position when both solenoids are deenergized. As a consequence, longer stroking spool type solenoid valves are used which results in lower shifting forces. MAC s latching solenoid technology eliminates the sealing issue with poppets when no electrical signal is applied, by maintaining solenoid force, ensuring adequate sealing, while using short stroking poppets resulting in high shifting forces. MAC s latching solenoid only requires one solenoid and correspondingly one plug-in and one conduit wireway verus two for conventional double solenoid valve, saving space, weight and cost. An added benefit of a latching solenoid valve when mounted on a circuit bar is the additional option of side cylinder ports. HOW IT WORKS Unlike a spool and bore valve, a poppet valve requires that a force be continuously applied to either end of the poppet to ensure that proper sealing occurs. If another solenoid was simply added to the valve to create a double solenoid valve, power would need to be constantly applied to either solenoid for the valve to function properly (see Figure 1). If the poppet valve is converted to a spool and bore type valve design, the longer stroke of the spool and solenoid would result in lower net shifting forces (see Figure ), compromising the valves shifting reliability. Solenoid Poppet Solenoid Solenoid Spool Solenoid Long Solenoid Stroke Figure 1 : Double Solenoid Poppet Figure : Double Solenoid Spool Design The latching solenoid overcomes these problems by introducing a powerful permanent magnet armature assembly which magnetically latches itself to the pole piece and in turn keeps the poppet sealed against the conical seats when the power is removed from the solenoid. To shift the poppet in the opposite direction, the polarity of the voltage applied to the solenoid leads is reversed and the attractive force between the permanent magnet armature assembly and the pole piece is reduced. The return spring in the valve then shifts the poppet to its other sealing position and the permanent magnet armature assembly is then magnetically attracted to the upper latch. The upper latch prevents the permanent magnet armature assembly from attracting itself back to the pole piece when the voltage is removed. Reversing the polarity again to the solenoid lead wires will create a powerful attractive force between the permanent magnet armature assembly and the pole piece and away from the upper latch which will correspondingly move the poppet to the other shifted position. Armature Push Pin Coil Conical Seat (cushioning) Exh A Cyl A Poppet Circuit Board Upper Latch Lower Latch Pole Piece Valve Spring Figure : Latching Solenoid Design Inlet Cyl B Exh B 4 Consult Precautions page 7 before use, installation or service of MAC Valves..

Technical Info WIRING INSTRUCTIONS AND OPTIONS As shown in Figure 4, a conventional double solenoid valve requires that the pair of lead wires from each solenoid be wired to an appropriate voltage source, MAC's latching solenoid technology has the option of being wired in one of the three () currently available methods. + SOLENOID "A" - + SOLENOID "B" Figure 4 : Conventional Double Solenoid - WIRING SCHEMATIC FOR DOUBLE SOLENOID FOUR WIRE As shown in Figure 5, the four wire method enables the coil to be wired as if it were a conventional double solenoid. By connecting the yellow lead wire to positive voltage and the yellow lead wire with black stripe to negative, the valve will be open to cylinder port A. When positive voltage is supplied to the red lead wire and negative to the red lead with a black stripe, the valve will now be open to cylinder port B. Since the negative red and yellow lead wires are internally connected together, the supply voltage for each pair of yellow and red lead wires must be isolated from the other pair (see diagram). Also, power must not be applied to all four leads simultaneously or a short circuit condition will occur possibly damaging the voltage source. Red/Black Stripe Red Yellow Yellow/Black Stripe No circuit board needed Wired as conventional double Must isolate pairs of red and yellow wires from each other + - Figure 5 : Four Wire Latching (+) POS IN A - Yellow (+) POS IN B - Red (-) NEG IN A Yellow/W/Black Stripe (-) NEG IN B Red/W/Black Stripe 4 WIRE SCHEMATIC FOR LATCHING THREE WIRE Unlike the two wire method ( see Figure 7) which requires the user to provide the polarity switching circuitry, the three wire method incorporates the polarity switching circuitry within the solenoid enclosure ( see Figure 6). The black lead wire provided must be connected to positive and is used as a common. When negative voltage is supplied to the yellow lead wire with a black stripe the valve will be open to cylinder port A. When the negative voltage is removed from the yellow lead wire with the black stripe and supplied to the red lead wire with a black stripe, the valve will now be open to cylinder port B. Applying voltage to all three wires simultaneously or with the wrong polarity will cause permanent damage to the switching circuitry in the solenoid cover, and the valve won t work. Red/Black Stripe (-) Neg In Cyl B Operation Black (+) Positive Common Yellow/Black Stripe (-) Neg In Cyl A Operation Switching done on circuit board within valve Do not apply power to all wires simultaneously Figure 6 : Three Wire Latching YELLOW W/BLACK STRIPE (+) IN A (-) IN B RED W/BLACK STRIPE BLACK (+) COMMON WIRE SCHEMATIC FOR LATCHING 5 Consult Precautions page 7 before use, installation or service of MAC Valves..

Technical Info TWO WIRE The two wire method shown in Figure 7, provides a black and red lead wire connected to the solenoid. The user must provide the polarity switching circuitry to these leads in order to shift the valve to its two positions. By applying positive DC voltage to the red lead wire and negative to the black, the valve will be open to cylinder port A. When the polarity of the voltage is externally reversed to the lead wires the valve will now become open to cylinder port B. Red Black Figure 7 : Two Wire Latching No circuit board needed Customer must switch polarity of voltage Red to Positive and Black to Negative yields flow to cylinder port A Red to Negative and Black to Positive yields flow to cylinder port B AVAILABLE OPTIONS The and 4 wire connections are available in both a flying lead and plug-in cover. The wire connection is only available in the plug-in style cover. All and 4 wire cover options are available with an LED indicator. The LED indicator on a wire cover is standard. The LED will illuminate red for cylinder A operation and green for cylinder B operation. The wire connection must be used for valves connected to either a multi-pin connector or a serial manifold. Mixing single solenoids with latching solenoids on a circuit bar is possible since each station of the bar is wired for a latching coil. The circuit bar must be ordered with this wiring configuration. If required, a negative common wire connection is also available, please consult factory. HOW TO ORDER The numbering system for a latching solenoid differs from the numbering system for a single solenoid valve. The letter L within the model number indicates a latching solenoid, while the letter G or "H" in the same position of the model number indicates a single solenoid valve. 6 Consult Precautions page 7 before use, installation or service of MAC Valves..

7 PRECAUTIONS AND WARNINGS CONCERNING THE APPLICATION, INSTALLATION AND SERVICE OF MAC VALVES AND OTHER MAC VALVES PRODUCTS The warnings and precautions below are important to be read and understood before designing into a system any MAC Valves products, and before installing or servicing any MAC Valves product. Improper use, installation or servicing of any MAC Valves product in some systems could create a hazard to personnel or equipment. No distinction in importance should be made between the terms warnings and precautions. WARNING :. Under no circumstances are MAC Valves products to be used in any application or in any manner where failure of the MAC Valves product to operate as intended could in any way jeopardize the safety of the operator or any other person or property. Do not operate outside of pressure range listed on a valve label or outside of the designated temperature range. Air supply must be clean and dry. Moisture or contamination can affect proper operation of the valve. Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts & operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. If air line lubrication is used do not use any lubrication other than those recommended in the catalog, parts & operation sheet or by the factory. APPLICATION PRECAUTIONS :. INDUSTRIAL USE - MAC Valve products are intended for general use in industrial pneumatic and/or vacuum systems. They are general purpose industrial products with literally thousands of different applications in industrial systems. These products are not inherently dangerous, but they are only a component of an overall system. The system in which they are used must provide adequate safeguards to prevent injury or damage in the event failure occurs, whether it be failure of switches, regulators, cylinders, valves or any other component. POWER PRESSES - MAC Valve products are not designed nor intended to be used to operate and/or control the operation of clutch and/or brake systems on power presses. There are special products on the market for such use. -POSITION VALVES - Some MAC valves are -position, 4-way valves. When air is supplied to the inlet port(s) of these valves, there will always be a flow path from the inlet to one of the outlets regardless of which of the two positions the valve is situated. Therefore, if pressurized air retained in the system would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the trapped air. - POSITION VALVES- Some MAC valves are -position, 4-way valves. These valves are either double solenoid or double remote air operated. If either of the two operators is in control, air supplied to the inlet port(s) will pass through the valve to one of the outlets as on -position, 4-way valves. However, if neither operator is in control, the valve moves to a center position. Listed below are the various center position functions : A. CLOSED CENTER- With this type valve, when in the center position all ports are blocked (inlets and exhausts) meaning the air at both outlet ports is trapped. If trapping the air in both outlet ports would present a hazard in the application or servicing, a separate method in the system must be provided to remove the trapped air or this type valve should not be used. B. OPEN CENTER- With this type valve, when in the center position, the inlet port(s) is blocked and the two outlet ports are open to the exhaust port(s) of the valve. If having no air in either outlet port would present a hazard in the application or servicing, this type valve should not be used. C. PRESSURE CENTER- With this type valve, when in the center position, the inlet port(s) is connected to both outlet ports of the valve. If having pressurized air to either or both outlet ports would present a hazard in the application or servicing of the valve or system, a separate method in the system must be provided to remove the retained air or this type valve should not be used. OPERATING SPECIFICATIONS - MAC Valves products are to be installed only on applications that meet all operating specifications described in the MAC catalog for the MAC Valves product. MANUAL OPERATORS- Most MAC valves can be ordered with manual operators. Manual operators when depressed, are designed to shift the valve to the same position as would the corresponding solenoid or remote air pilot operator if it were activated. Care must be taken to order a type, if any, that will be safe for the physical location of the manual operator in the system. If intentional or accidental operation of a valve by a manual operator could cause personal injury or property damage, a manual operator should not be used. REMOTE AIR OPERATED VALVES Pilot valves supplying signal pressure to remote air operated valves should be -way valves with adequate supply and exhaust capacity to provide positive pressurizing and exhausting of the pilot supply line. Pilot lines should be open to exhaust when valves are deenergized. INSTALLATION PRECAUTIONS :. A. Do not install any MAC Valves product without first turning off air (bleed system completely) and electricity to the machine. B. MAC Valves products should only be installed by qualified, knowledgeable personnel who understand how the specific valve is to be pneumatically piped and electrically connected (where applicable). Flow paths through the valve are shown in the catalog and on the valve by use of ANSI or ISO type standard graphic symbols. Do not install unless these symbols and the valve functions and operations are thoroughly understood. C. If air line lubrication is used do not use any lubrication other than those recommended in the catalog, parts & operation sheet or by the factory. SERVICE PRECAUTIONS : A. Do not service or remove from service any MAC Valves product without first shutting off both the air and electricity to the valve and making certain no pressurized air which could present a hazard is retained in the system. B. MAC Valves products should only be serviced or removed from service by qualified, knowledgeable personnel who understand how the specific product is used and/or how the specific valve is piped and used and whether there is air retained in the connecting lines to the valve or electric power still connected to the valve. C. Before attempting to repair, adjust or clean a MAC Valves product, consult catalog, parts & operation sheet, or factory for proper maintenance procedures, lubrication and cleaning agents. Never attempt to repair or perform other maintenance with air pressure to the valve. D. MAC Valves products are never to be stepped on while working on a machine. Damage to a MAC valve, or other product or lines to the product (either air or electrical lines) or accidental activation of a manual operator on the valve could result in personal injury or property damage. LIMITATION OF GUARANTEE. This Guarantee is limited to the replacement or rebuilding of any valve or other product which should fail to operate properly. Valves or other products, under the MAC Guarantee, must be returned (with or without bases) transportation prepaid and received at our factory within the Guarantee period. They will be returned to the customer at the expense of MAC Valves, Inc., and will carry the same guarantee as provided under the Flat Rate Rebuild Program. DISCLAIMER OF GUARANTEE. No claims for labor, material, time, damage, or transportation are allowable nor will any valve or other product be replaced or rebuilt under this guarantee which has been damaged by the purchaser not in the normal course of its use and maintenance during the warranty period. The guarantee does not apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes beyond the control of MAC Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special or consequential damages under the MAC Guarantee, nor under any implied warranties, including the implied warranty of merchantability. The above Guarantee is our manner of extending the engineering and service resources of the MAC Valves, Inc. organization to assure our customer long, and continued satisfaction.

MAC Valves Product Warranty Information MAC VALVES Warranty, Warranty Limitations, Flat Rate Rebuild Program The MAC Valves organization has established a reputation over many years for fulfilling the needs and requirements of the users of its products. All MAC Valves are quality products specifically designed and built for long and rugged service. For this reason, MAC Valves is able to provide the Buyer a limited warranty. WARRANTY: MAC Valves, Inc. hereby warrants to Buyer that, for a period of 18 months from the original date of shipment of each valve from our factory ( Warranty Period ), such valve will be free from significant defects in material and workmanship and will conform to all specifications agreed to by MAC Valves, Inc.. In addition, MAC Valves, Inc. warrants that the electrical coils on such valves will be free from significant defects in material and workmanship for their normal useful life. EXCEPT FOR THESE LIMITED WARRANTIES, MAC VALVES, INC. EXPRESSLY DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES OF ANY KIND (WHETHER EXPRESS, IMPLIED OR ARISING BY OPERATION OF LAW) WITH RESPECT TO THE VALVES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER. THIS SECTION SURVIVES THE EXPIRATION, TERMINATION OR CANCELLATION OF ANY AGREEMENTS BETWEEN THE PARTIES RELATING TO THE PURCHASE OF THE VALVES. WARRANTY LIMITATIONS: This Warranty does not apply where the valves have been (i) subjected to abuse, misuse, damage, neglect, negligence, accident, improper testing, improper installation, improper storage, improper handling, abnormal physical stress, abnormal environmental condition, or use contrary to any instructions issued by MAC Valves, Inc.; (ii) modified, reconstructed, repaired, or altered by persons other than MAC Valves, Inc. or its authorized representative; or (iii) used with any third-party product, hardware, software or other product that has not been previously approved in writing by MAC Valves, Inc. Additionally, this Warranty does not cover claims for labor, material, time or transportation, and does not apply to loss or damage caused by fire, theft, riot, explosion, labor dispute, act of God, or other causes beyond the control of MAC Valves, Inc. EXCLUSIVE REMEDY: The Buyer s sole remedy under this Warranty is limited to the replacement or rebuilding of any valve which does not conform to the warranties provided herein or, in MAC Valves, Inc. s sole discretion, refund of the purchase price for the non-conforming valve. Buyer s remedy is conditioned on Buyer s compliance with its obligations under this Warranty. Valves that Buyer believes do not conform to this Warranty must be returned (with or without bases) transportation prepaid and received at our factory within the Warranty Period. If MAC Valves, Inc. determines that the valve is non-conforming and is otherwise covered by this Warranty, the rebuilt or replaced valve will be returned to the customer at the expense of MAC Valves, Inc., and will carry the same warranties as provided under the Flat Rate Rebuild Program described below. MAC VALVES, INC. WILL NOT BE RESPONSIBLE FOR ANY INCIDENTAL, SPECIAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION DIRECT AND INDIRECT LOST PROFITS, REGARDLESS OF WHETHER THOSE DAMAGES WERE FORESEEABLE. THE FLAT REBUILD PROGRAM: Valves no longer covered by the MAC Warranty may be eligible for a one-time rebuild under the MAC Valves, Inc. Flat Rate Rebuild Program. Our constant research and testing program is dedicated to extending the life of our valves and maximizing their reliability under the most adverse conditions. Valves returned under this limited program are completely disassembled, inspected, rebuilt to current operating standards whenever possible, tested and returned within a few weeks for a nominal flat rate charge. All rebuilt valves carry the same warranty described (in our MAC Warranty) for new valves for a warranty period of 90 days from the date of shipment from our factory. Valves that have gone through the one-time rebuild will have been marked with a letter R as part of the date stamp (This is an example of a rebuild date stamp from this month E(May)17(Year)Tester Symbol R(Indicates Rebuild). Please note that any valves sent back for subsequent rebuild that have already been through the program previously (indicated by the R ) will not be eligible for additional rebuild.

Notes........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... 8

MAC VALVES, INC. P.O. BOX 111 0569 BECK ROAD WIXOM, MI 489-7011 TEL: 1-800-MAC VLVS TEL: 1 (48) 64-7700 FAX: 1 (48) 64-0549 E-mail: Mac@macvalves.com Web Site: www.macvalves.com MAC VALVES EUROPE, INC. RUE MARIE CURIE, 1 B-441 ANS (LIEGE) BELGIUM TEL: (4) 9 68 68 FAX: (4) 6 19 4 E-mail: Info@macvalves.be MAC VALVES PACIFIC, INC. P.O. BOX 11 PENROSE, AUCKLAND NEW ZEALAND TEL: 64 (9) 64-9400 FAX: 64 (9) 64-9401 E-mail: Macvalves@xtra.co.nz 999CTCB - 04/0 MAC VALVES, INC. 5555 ANN ARBOR ROAD DUNDEE, MICHIGAN (MI) 4811 U.S.A. TEL: 1 (74) 59-5099 FAX: 1 (48) 86-111