Installation Instructions

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Cable-Operated Disconnect Switches. Accessories

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Installation Instructions for Replacement Mechanism Kit

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

INSTALLATION INSTRUCTIONS RATTLER STEEL RUNNING BOARDS FORD TRANSIT VAN (FULL SIZE)

OPERATOR ADAPTER ABBSV

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

Patriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)

OPERATOR ADAPTER ABF

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

OPERATOR ADAPTER A21ABA

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

600V, Non-Fusible, (3-Pole, 3 Phase)

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

P3066 INSTALLATION MANUAL

PARTS TOOLS. Set Screw. Washer (2) Blue Bushing (2) Black Bushing (2) B&M Short Throw Shifter. Jam Nut Grease. Retaining Ring (2) Insert (2)

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

INSTALLATION INSTRUCTIONS Unitronic 3 Turbo-Back Exhaust System for MK5 Jetta /GLI UH020-EXA

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

Instruction Sheet Kit Number:

INSTALLATION INSTRUCTIONS Unitronic Turbo-Back Exhaust System for MK7 GTI UH026-EXA

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

920 Remote Control Switches

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

Installation Instructions

INSTALLATION INSTRUCTIONS

ENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions

Operation and Maintenance Manual

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Covers for Cast Iron or Aluminum Device Boxes

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

24in Stand-On Aerator

Kit No Please read these instructions completely before proceeding with installation. Air Spring Kit Parts List. Bracket Attaching Hardware

TOYOTA FJ CRUISER AIR DAM/LIGHT BAR Preparation

INSTALLATION MANUAL P2068. Level of Difficulty. Parts List. Product Image. Notes and Maintenance. Tools Required. Easy

Part Name/Description Part No. PF3000 PF 3000 Pro U-Bracket Short Bracket PF3000 Pro

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

WARNING! THIS SHIFTER IS FOR RACING USE ONLY. NOT FOR STREET USE!

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

INSTALLATION INSTRUCTIONS Dodge Ram Crew / Mega 2500/3500 2/4WD NOTE: (tow hooks will not be re-attached) PART # P5056

INSTALLATION INSTRUCTIONS Unitronic Downpipe for AWD 2.0 TSI Gen3 MQB UH027-EXA

Recommended Tools: 3/8 drive ratchet 3/8 drive 13mm deep socket 3/8 drive 15mm deep socket 3/8 drive 15mm shallow socket 13mm wrench

CH1900 Series Electronic Control Installation Manual... includes CP1200 Operator Panel MANIN1900 Revision 0

GM Duramax Diesel

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

INSTRUCTIONS INSTRUCCIONES CONSIGNES

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

Big performance in a small package

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

GT Mustang Shaker

2011 Cadillac CTS Coupe EGX Exhaust Tip & Rear Valance Mesh Accent Kit Part #: Complete E

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

Load Break Disconnect Switches FSLBS

Plow Partner Mounting Kit M

Models Affected: Certain 2015 & 2016 All American Front Engine and Vision Buses Equipped with Hydraulic Brakes ISSUE _ CORRECTIVE ACTION _

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Installation Instructions QUARTER STICK Fits: 2 Speed (Powerglide) or 3 Speed (Turbo-Hydramatic)

Detroit Speed, Inc. Selecta-Speed Wiper Kit Mustang P/N:

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Please read these instructions completely before proceeding with installation. Read all maintenance guidelines on page 7 before operating the vehicle.

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

EXTERNAL DISCONNECT ENCLOSURE INSTALL

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

NEVER STOP CORRUGATE OPENER

A Zy-Tech Global Industries Product

69-74 VW Beetle IRS Rear Kit Part No

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

SEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

Installation Instructions

Product Guide. NEMA pump controls.

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

SERVICE MANUAL (INTERNATIONAL)

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

CONCEPT Wall-Mount Enclosure Accessories

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER:

Installation Guide. Philips MP20/30/40/50 IntelliVue VHM Wall Mount Kit

INSTALLATION INSTRUCTIONS FORD SUPER DUTY NOTE: (Vehicle Retains Tow Hook) PART # P3064

Installation Instructions

Publication: PDI-010 Date: March 5, 2010 Model: UXV 500

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

CrossOver X45 Lock Installation Need another copy of these installation sheets? You can download one at

Transcription:

Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. Components Cat No. Description Switch Rating (Amps) 494V-H 494V-R 494V-W 7-/" Painted Metal Handle 7-/" Molded Handle 7-/" Stainless Steel Handle L L L 494V-DS 494V-DS Amp Switch Amp Switch 494V-RB 494V-RB 494V-FS 494V-FS 49-N6 49-R6 Standard Connecting Rod ( per kit) Enclosure Working Depth: 9" to 9-/4" Extended Connecting Rod ( per kit) Enclosure Working Depth: 9" to " Amp Fuse Block Amp Fuse Block (Class J fuses only) A 50V/V Class H A 50V/V Class R 40-N46 40-N45 40-N54 40-N55 Fuse Clip, Class H, J, A - 50V, A - V Fuse Clip, Class H,J, 00A-50V, 00A-V Fuse Clip, Class R, 00A-50V, 00A-V Fuse Clip, Class R, A-50V, A-V 595-A 595-B 595-N 494R-N0 494R-N 494R-N () N.O. Auxiliary Contact () N.C. Auxiliary Contact Auxiliary Contact Adapter Kit Lug Connector: Wire Size () #/0-50 MCM Lug Connector: Wire Size () #/0-50 MCM Lug Connector: Wire Size #4...500 MCM 495-N6 Fuse Cover with Door (only for Right-Hand Installation)

Handle Installation Locate Handle C B B C A A E E Door Catch Mounting D D Door Catch Mounting Right Hand Flange Left Hand Flange NEMA SIZE A (min) B (min) C (max) D E F G H J K L M A 4 - /6" 9/" - 7/" - 5/8" - 49/64" 6 - /" " 5" 9/6" /" /4" /4" Drill Handle Holes K L A 8 - /6" 9/" - 7/" - 5/8" - 49/64" 6 - /" " 5" 9/6" /" /4" /4" () - /64" Dia. Holes DIMENSIONS NOT SUITABLE FOR 494V-R HANDLE Locate Door Catch Mounting Enclosure Door H J G F Door Catch Mounting 0 lb-in M Enclosure Base Door Catch C Square Corners or /4" R. D Notes: A) Enclosures with a Flange Thickness less than /6" use dimensions above. B) Enclosures with a Flange Thickness /6" and greater use dimensions in Mounting Kit 494V-H6. This kit requires "B" dimension of -7/" min. C) For large enclosure use -/8" "M" dimension, using large enclosure door hardware (494V-L, 494V-LL). D) The door catch mounting bracket is provided with projections for welding; however, holes can be drilled in the bracket using the projections for locating hole centers. After proper location, it may be used as a template and drill corresponding holes in the enclosure door. Fasten the bracket with hardware supplied by user. If properly assembled, the hardware should not be accessible for tampering with by unauthorized personnel. 4 Install Gasket Important: Use grease from grease capsule to keep o-ring seal in handle groove during installation. 5 Install Handle to Flange 6 Install Defeater Lever (Note: After handle is mounted on the enclosure flange.) B 7- lb-in 50-65 lb-in ()

Disconnect Switch Installation Locate Disconnect Switch CC AA GG CC HH HH BB BB DD DD Right Hand Flange Left Hand Flange NEMA SIZE AA BB CC DD GG HH A A - 5/64" 6-5/" 8-7/64" 4 - /" - 5/64" (4) 5/6-8 - 5/64" 6-5/" 8-7/64" 4 - /" - 5/64" (4) 5/6-8 Conversion from Right-Hand Installation to Left-Hand Installation With the disconnect switch in the "OFF" position, (blades visible) loosen and remove the () hex head screws. Remove the drive mechanism from the right-hand side of the disconnect switch. Save the () 5/6-8 hex head screws shown below. Rotate the crossbar assembly to the "ON" position (blades fully engaged - not visible). (Use any convenient adjustable wrench to aid in rotating the crossbar & moveable blades. L L L L L L 4 ATTENTION: Do not attempt to change the position of the drive mechanism after removal from the disconnect assembly. Position the drive mechanism assembly as shown below and install the () 5/6-8 hex head screws. L L L 40-60 lb-in ()

Trailer Fuse Block and Fuse Clip Installation Install Trailer Block Install Fuse Clips Q R Y V AA 40 lb-in Z BB CC X Install Wire Lugs to Terminals S L L L 4 S (4)

4 Install Wire to Lugs T L L L 8 lb-in T Q R S T * Switch Fuse Rating Rating Fuse (Amps) (Amps/Volts) Class Trailer Fuse Fuse Fuse Block Fuse Clip Lug to Wire to Fuse Block Clip V X Y Z Block Mtg. Screw Mtg. Screw Terminal Lug Catalog Catalog (inches) (inches) (inches) (inches) Mounting Torque Torque Torque Torque Number Number Screw (lb-ins.) (lb-ins.) (lb-ins.) (lb-ins.) Term Screw or Stud AA (inches) BB (inches) CC (inches) 00A, 50V H 494V-FS 40-N45 /6 6-/4-7/ -5/6 5/6-8 90-0 0 75 5 -/6 -/6 00A, 50V R 494V-FS 40-N54 /6 6-/4-7/ -5/6 5/6-8 90-0 0 75 5 -/6 -/6 00A, V H 494V-FS 40-N45 /6 6-/4 4-/ -6/64 5/6-8 90-0 0 75 5 00A, V R 494V-FS 40-N54 /6 6-/4 4-/ -6/64 5/6-8 90-0 0 75 5 00A, V J 494V-FS 40-N45 /6 6-/4 9/ -5/6 5/6-8 90-0 0 75 5 /- -/6 -/6 A, 50V H 494V-FS 40-N46 /6 6-/4 -/6-5/6 5/6-8 90-0 0 75 5 A, 50V R 494V-FS 40-N55 /6 6-/4 -/6-5/6 5/6-8 90-0 0 75 5 A, V H 494V-FS 40-N46 /6 6-/4 5-/6-5/6 5/6-8 90-0 0 75 5 A, V J 494V-FS 40-N46 /6 6-/4 -/6-5/6 5/6-8 90-0 0 75 5 A, V R 494V-FS 40-N55 /6 6-/4 5-/6-5/6 5/6-8 90-0 0 75 5 A, 50V H 494V-FS 40-N46 /64 6-/4 -/4-5/6 5/6-8 90-0 0 75 5 A, 50V R 494V-FS 40-N55 /64 6-/4 -/4-5/6 5/6-8 90-0 0 75 5 A, V H 494V-FS 40-N46 /64 6-/4 4-/4-5/6 5/6-8 90-0 0 75 5 A, V J 494V-FS 40-N46 /64 6-/4 -/ -5/6 5/6-8 90-0 0 75 5 A, V R 494V-FS 40-N55 /64 6-/4 4-/4-5/6 5/6-8 90-0 0 75 5 /- A, 50V H 49-N6 () 5/6-8 60 75 5 A, 50V R 49-R6 () 5/6-8 60 75 5 A, V H 49-N6 () 5/6-8 60 75 5 A, V J 494V-FS () /64 6-/4 4-/ -5/6 5/6-8 90-0 5 75 5 A, V R 49-R6 () 5/6-8 60 75 5 * When lug kits 494R-N0 & 494R-N are used. (5)

Connecting Rod Installation N Enclosure Working Depth (Flange to Mounting Plate) Connecting "N" Catalog Number Rod Min. Max. Standard 494V-RB 9" 9-/4" Extended 494V-RB 9" " N - " Right Hand Operation Front a) Install connecting rod into the support rod bracket and thread in clockwise (5) full turns b) Install connecting rod into the drive bar mechanism and thread in clockwise (9) full turns a) Place the disconnect handle in the "OFF" position. Attach the end of the connecting rod to the primary link of the handle with two /4-0 x /" slotted head screw assemblies and tighten to 40 lb-in torque. b) Attach the second connecting rod to the top of the spring bracket with two /4-0 x /" slotted head screw assemblies and tighten to 40 lb-in torque. c) Attach the two springs to the mechanism as shown below: Spring Support Rod Drive Mechanism Connecting Link Connecting Rod Adjustment Procedure 4 "ON" Position a) Move disconnect handle to the "ON" position. b) If switch does not fully close, return handle to "OFF" position. c) Loosen and remove the two /4-0 slotted hex head screw assemblies that hold the connecting rod to the connecting link. d) Turn connecting rod counter-clockwise () full turn. e) Re-assemble the two /4-0 hex head assemblies and tighten to 40 lb-in and re-test. f) Repeat 4a - 4e as necessary. 5 "OFF" Position g) Move disconnect handle to the "OFF" position. h) If switch does not fully open, return handle to "ON" position. j) Loosen and remove the two /4-0 slotted hex head screw assemblies that hold the connecting rod to the connecting link. k) Turn connecting rod clockwise () full turn. l) Re-assemble the two /4-0 hex head assemblies and tighten to 40 lb-in and re-test. m) Repeat 5g - 5l as necessary. (6)

Left Hand Operation 6 a) Install connecting rod into the support rod bracket and thread in clockwise (5) full turns b) Install connecting rod into the drive bar mechanism and thread in clockwise (9) full turns 7 a) Place the disconnect handle in the "ON" position. Attach the end of the connecting rod to the primary link of the handle with two /4-0 x /" slotted head screw assemblies and tighten to 40 lb-in torque. b) Attach the second connecting rod to the top of the spring bracket with two /4-0 x /" slotted head screw assemblies and tighten to 40 lb-in torque. c) Attach the two springs to the mechanism as shown below: Spring Support Rod Connecting Link Drive Mechanism Connecting Rod Adjustment Procedure 8 "ON" Position a) Move disconnect handle to the "ON" position. b) If switch does not fully close, return handle to "OFF" position. c) Loosen and remove the two /4-0 slotted hex head screw assemblies that hold the connecting rod to the connecting link. d) Turn connecting rod counter-clockwise () full turn. e) Re-assemble the two /4-0 hex head assemblies and tighten to 40 lb-in and re-test. f) Repeat 8a - 8e as necessary. 9 "OFF" Position g) Move disconnect handle to the "OFF" position. h) If switch does not fully open, return handle to "ON" position. j) Loosen and remove the two /4-0 slotted hex head screw assemblies that hold the connecting rod to the connecting link. k) Turn connecting rod clockwise () full turn. l) Re-assemble the two /4-0 hex head assemblies and tighten to 40 lb-in and re-test. m) Repeat 9g - 9l as necessary. Auxiliary Contact Installation Auxiliary Contact Adapter 595-N L L L Auxiliary Contact 595-A, 595-B 40 lb-in (7)

Fuse Cover Installation Removal 405-07-0 () Printed in U.S.A.