HYDAC ACCUMULATORS DEVELOPMENT AND ENGINEERING

Similar documents
Permanent Gauging Blocks Installation Instructions

Introduction 2 INNOVATIVE FLUID POWER. Functions. Benefits. Accessories. Development and Engineering. Manufacturing and Assembly

Hydraulics. Hydraulic Accumulators Introduction

PN# / 1.15 / ACU Accumulators. Bladder, Piston, Diaphragm

Diaphragm Accumulators AD Series

Replacement Elements

Thermal Fuse Caps. Thermal Fuse Caps INNOVATIVE FLUID POWER 51. Description. Applications. Model Code. Installation. Technical Data.

Bladder Accumulators za03 Bottom Repairable Top Repairable Medium Flow High Flow Transfer Barrier Gas Bottle

Thermal Fuse Caps Description Applications Model Code Order Part No Installation Technical Data Maximum Working Pressure

Mounting Components. Mounting Components 70 INNOVATIVE FLUID POWER. HS - Regular Duty Clamp. Function. HSS - Heavy Duty Clamp.

Pressostats and thermostats CAS

Bladder Special Orders 46 Accumulator Selection, Commissioning, Installation & Maintenance 47

HIGH PRESSURE BALL VALVES

Metal Bellows Accumulators for Heavy Diesel Engines

Accumulators, Accessories and Spares

Be sure to order the correct number of elements: OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

Safety Equipment for Hydraulic Accumulators

HYDRAULIC ACCUMULATORS SERVI FLUID POWER, INC. GLOBAL RESOURCE FOR HYDRAULIC ACCUMULATORS

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

The Eaton Advantage. machinery using accumulators.

Safety Equipment for Hydraulic Accumulators

Accumulators, Accessories and Spares

Accumulator charging valves & kits

Series 111 Accumulator Product Information

A c c u m u l at o r. The pressure is always on.

Pressure and temperature controls, Type CAS

Pressure controls and thermostats, type KPS

Accumulator. The pressure is always on.

Bladder-type accumulators

Expertise. Hydraulics. What you should know about us. excellent pressure solutions

MODEL NUMBERS UPDATED. Accumulator. The pressure is always on.

HPUs Hydraulic Power Units

Selecting and Applying Accumulators

Hydraulic Accumulators Introduction

HOW THE SPRAGUE PRODUCTS BOOSTERS WORK

Safety & Shut-off Blocks

Series 812. TÜV/CE atmospheric discharge safety valves for industrial applications. Air, gases and vapours

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Inline Pulse-Tone. Hydraulic Shock Suppressors. Inline Pulse-Tone Shock Suppressors Feature:

Oil & Gas industry. Cryogenic & Oxygen service

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

the piston accumulator company

Three-phase motors for marine use

ALBRECHT-AUTOMATIK GMBH

Ekip Link logic- zone discrimination protection system

Pressure switch and Thermostat Type CAS

AutoFilt RF3 Automatic Self-Cleaning Filter

Expansion Tanks. In pressure boosting systems. Features of accumulator vessels. In closed heating and cooling circuits

Thermal Expansion Absorber For Potable Water TX SERIES TANKS

HIGH PRESSURE FILTERS Series HF2P

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Series RFLD Duplex In-Line Filter

AutoFilt RF3 Automatic Self-Cleaning Filter

HIGH PRESSURE FILTERS

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

APP S 674 pumps APP S / APP S APP S

Hydropneumatic Accumulators and Pulsation Dampers

KKAI Report No Rev 1 Prepared for BioHeatUSA April 28, 2009

SINAMICS S120 Cabinet Modules Application Shaft Generator Drive

HYDRAULIC PISTON ACCUMULATORS

HYDROPNEUMATIC ACCUMULATORS DIAPHRAGM BLADDER BLADDER-DIAPHRAGM PISTON

EFFECT OF HYDRAULIC ACCUMULATOR ON THE SYSTEM PARAMETERS OF AN OPEN LOOP TRANSMISSION SYSTEM

HYDAC PISTON ACCUMULATORS INDEX Page:. DESCRIPTION..FUNCTION..CONSTRUCTION.3.SEALING SYSTEMS 3.4.MOUNTING POSITION 3.5.ADVANTAGES OF HYDAC PISTON ACCU

ME High Pressure Stage Casing Pump

Powerful, versatile and reliable. Planetary Plug-in Gearboxes by Liebherr

OUR ASSETS OUR SCOPE OF SUPPLY. Ball Valves Gate Valves Globe Valves Control Valves Check Valves Butterfly Valves Plug Valves Special Valves

Air Driven Gas Boosters

Sprague Air Driven Pumps, Gas Boosters & Power Units

Nomenclature... xi Hydraulic Laws, Theorems, and Equations...xii

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

MC High Pressure Stage Casing Pump

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

Products and Services for the Energy Industry

SPIN-ON FILTERS & ELEMENTS

CASH VALVE K SERIES BACK PRESSURE VALVES

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

XCITE. Reso-not TM Damping System XCITE. Model No ZSP-101-P2-38 Foot Mount Damper with 1 Quart Accumulator System

Content. Pilot & Embarkation rope ladders 4 M.E.D. and USCG approved.

DA Series Diaphragm Accumulators

HIGH PRESSURE FILTERS

Company Presentation 05/20/2014 Release 06 1

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4" ( mm) U.S. Patent # Patented Easy Maintenance!

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

Heavy duty pressure switch MBC 5000 and MBC 5100

HIGH PRESSURE FILTERS

MD High Pressure Stage Casing Pump

Overview. Field proven- Over 8,000 frac valves installed over the last 10 years

SPRAGUE PRODUCTS AIR DRIVEN HYDRAULIC PUMPS

Flojet Rewrites the Book on Small Pump Control

All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines

05 Water Pressure Systems INTRODUCTION

Model &

HPB Hydraulic Power Braking System

Air Driven Hydraulic Pumps, Gas Boosters, Power Units, Specialty Valves & Accessories L & LS SERIES

Advanced Air Driven Gas Boosters and Amplifiers. Sprague. Air Amplifiers. Gas Boosters

Reliable and powerful starting for diesel engines and generators

Quick Disconnect Couplings & Hydraulic Valves

Water Treatment Plant Maintenance Considerations. Operation and Maintenance. Types of Maintenance 5/1/15

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

Transcription:

HYDAC ACCUMULATORS HYDAC accumulators - a name synonymous with advanced technology, design, manufacturing and application engineering for more than 35 years. As an essential element in modern hydraulics, accumulators perform many useful functions, such as: reducing pump capacity and electrical energy providing auxiliary hydraulic power in case of an emergency limiting pressure fluctuations during temperature changes in a closed hydraulic loop compensating for leakage minimizing pump pulsations absorbing shocks Utilization of accumulators offers many benefits including: increasing system performance and efficiency lowering operating and maintenance costs providing fail-safe conditions avoiding pump, pipe and system failures to achieve longer life expectancy HYDAC offers all types of accumulators: bladder accumulators diaphragm accumulators piston accumulators dampeners 1 1 HYDAC Corporation Accumulator Division, Bethlehem, PA 2 CAD and FE-Analysis 3 Development 4 Laboratory for elastomer tests 5 Laboratory test stand All accessories needed for proper installation and maintenance of accumulators are available, including: safety and shut off blocks mounting components accumulator sets charging and gauging units DEVELOPMENT AND ENGINEERING Based on research and development in our laboratories for testing of physical, chemical and mechanical properties, HYDAC achieves the highest quality of accumulators and related parts. Finite Element Analysis is implemented in the Computer Aided Design package supporting development and engineering to optimize the performance and safety of the components. Application assistance is available utilizing HYDAC computer software to simulate your system and optimize the sizing for energy savings, shock absorption or pulsation dampening. 2 4 2 3 5

MANUFACTURING AND ASSEMBLY Manufacturing and assembly at HYDAC are subject to strict quality control. HYDAC utilizes state-of-the-art manufacturing and quality assurance techniques. 6 9 7 10 8 11 6 Machining Department 7 Manufacturing Accumulator shells by spinning method. (Photo: MCS) 8 Assembly of bladder accumulators 9 Clean room 10 Electron-beam welding of diaphragm accumulators 11 Assembly of piston accumulators 3

CERTIFICATION Accumulators, more than any other fluid power component, are subject to a large number of inspections and code requirements, depending on where they are installed. HYDAC, a worldwide supplier of accumulators, will provide the appropriate design, inspection and documentation to suit the specific installation site, when it is clearly specified. A partial list of applicable pressure vessel certifications is listed below: ASME Code / U-Stamp Australian Standard British Standard Japan Industrial Standard Indian Standard Druckbehalterverordnung (Germany) Codap (France) Racolta (Italy) Swedish Pressure Vessel Code American Bureau of Shipping Bureau Veritas Det Norske Veritas (DNV) Germanischer Lloyd Korean Register of Shipping Lloyd s Register of Shipping Polski Rejettro Statkow Note: The Eurpean Community (EC) has the pressure equipment directive (PED) that is being phased in. Contact HYDAC for details. BLADDER ACCUMULATORS The standard bladder accumulator consists of a closed rubber bladder inside a forged steel shell. A mechanically actuated valve closes when the fluid has been expelled, blocking off the fluid port, thereby enclosing the bladder within the shell. Where high discharge rates are required, a high flow model is available, using a larger diameter fluid port. Applications with corrosive environments may require shells furnished with an internal and/or external coating or manufactured from stainless steel. The top repairable accumulator permits service and maintenance of the bladder without removing the accumulator from the machine. When the pressure level of a system permits, a low pressure accumulator may be used. It is similar to a standard bladder accumulator, except that the poppet valve is replaced by a perforated plate covering the fluid port, and the shell may be of welded construction. For applications requiring light weight a Kevlar wrapped accumulator shell is available. The wrapping supports the thinner metal shell to permit a substantial weight reduction. 4

Standard Bladder Accumulator Model: SB 330/600 Nominal Volume: 1 qt....15 gal. 3000...6000 PSI Low Pressure Bladder Accumulator Model: SB 35 Nominal volume: 2.5...120 gal. 275...500 PSI Bladder Accumulator with Kevlar Wrapped Construction High Pressure Bladder Accumulator Model: SB 800/1000 Nominal volume: 90 3 in Max working pressure: up to 14500 PSI High Flow Bladder Accumulator Model: SB...H (HT) Nominal volume: 2.5...25 gal. Max. flow rate: 480...2200 GPM 275...5000 PSI Top Repairable Bladder Accumulator Model: SB 330 T / 600 T Nominal volume: 2.5...15 gal. 3000...6000 PSI 5

DIAPHRAGM ACCUMULATORS A diaphragm accumulator performs the same function as a bladder accumulator, however, it operates like a membrane. A poppet is molded into the bottom of the diaphragm to prevent its extrusion through the fluid port. Diaphragm accumulators are frequently used where small volumes are required, light weight is important, a higher pressure ratio is required (up to 10:1) and low cost is a prime factor. Applications with corrosive environments may require shells furnished with an internal and/or external coating or manufactured from stainless steel. Automotive Application Welded Construction Model: SBO...-...E... Nominal volume: 5 in 3...230 in 3 1500...4700 PSI Threaded Construction Model: SBO...-...A.. Nominal volume: 6 in 3...120 in 3 3000...10000 PSI 6

STAINLESS STEEL ACCUMULATORS Stainless steel bladder, piston and diaphragm type accumulators are available in various sizes and pressure ranges. They offer special corrosion resistance, such as is needed for chemical and offshore industries, petro-chemical and nuclear power plants and for food applications. Bladder Accumulator Model: SB... Nominal volume: 90 in 3...120 gal. Max working pressure: 275...14500 PSI Diaphragm Accumulator Model: SBO Nominal volume: 5 in 3...120 in 3 Max working pressure: 1500...8700 PSI 7

PISTON ACCUMULATORS A wide range of piston accumulators is available. Piston position monitoring is available using proximity switches, extending piston rod or ultrasonic techniques. Auxiliary gas bottles are frequently used with piston accumulators to privide the required gas volume. Piston Accumulator Model: SK 350/600 Nominal volume: 1 qt...100 gal. Max working pressure: 3000...15000 PSI Piston Accumulator With other options such as: extending piston rod, ultrasonic piston monitoring Piston Accumulator With electrical proximity switches for end position control 8

DAMPENERS Pulsations and shocks in hydraulic lines can result in costly damage to the piping and other system components. Reciprocating piston pumps by design create pressure pulsations, vibrations, and noise in the system. HYDAC suction stabilizers, pulsation dampeners and silencers, when applied to piston pumps, will reduce pulsations and noise. Furthermore, pressure pulsations can make control in servo systems nearly impossible without installing a pulsation dampener. HYDAC shock absorbers can be applied to greatly reduce shock wave energy. These waves can be harmful to all components in your hydraulic system. Shock waves can be created by closing a valve in a high flow line, such as one found in a petroleum terminal. Suction Stabilizer Model: SB 16 S Nominal volume: 3...100 gal. up to 275 PSI Pulsation Dampener Type Bladder Accumulator Model: SB...P (PH) Nominal volume: 1 qt...10 gal. 3000...14500 PSI Pulsation Dampener Type Diaphragm Accumulator Model: SBO...P Nominal volume: 5 in 3...120 in 3 150...10000 PSI Shock Absorber Model: SB 35A Nominal volume: 25...120 gal. 275...500 PSI Silencer (Hydraulic Noise Attenuator) Model: SD250/400 Max. Flow Rate: 10...420 GPM Max working pressure: 3000...5800 PSI 9

ACCESSORIES A full range of accessories for the installation, service and maintenance of all accumulators completes the program. In addition to the items shown, special valve blocks and adapters are available for your particular requirements. Safety and Shut-off Blocks Model: SAB...M (E) Nominal size: 10...20...32 up to 5800 PSI Permanent Gauging Blocks and Thermal Fuse Cap For pressures up to 5800 PSI Mounting Components (clamps and brackets) Accumulator Sets 10 Charging and Gauging Units With flexible hose and pressure gauge for pressures up to 5800 PSI Mobile and Portable Nitrogen Charging Units For pressures up to 5000 PSI

ACCUMULATOR STANDS The assemblies shown here are representative of our custom engineered accumulator stands. We pride ourselves in our capability to provide an engineered solution for your application problem. Accumulator Stand for a Steel Mill Application Piston Accumulators with back-up nitrogen bottles Rather than using multiple piston accumulators, auxiliary nitrogen bottles are used to provide the required gas volume, thus reducing overall cost. This concept can also be used with bladder accumulators. Bladder/Piston Accumulator Stand 11

Other Products from HYDAC s Accumulator Line Bladder Accumulators The bladder style accumulator is a great general purpose accumulator. It has a wide range of sizes for energy storage requirements and is well suited for shock applications. Nominal volume: 1 qt. to 15 gal. 3000, 5000 and up to 15000 psi Flow rate: up to 480 gpm Diaphragm Accumulators Diaphragm accumulators are frequently used where small volumes are required, light weight is important, a higher pressure ratio is required (up to 10:1), and low cost is a prime factor. Two styles are available weld (nonrepairable) and threaded (repairable). Both are suited for energy storage and shock applications. Nominal volume: 5 in 3 to 1 gal. 3000, 4700, and up to 10,000 psi Flow rate: up to 40 gpm Piston Accumulators A wide range of piston accumulators is available. Piston position monitoring is available using proximity switches, extending piston rod or ultrasonic techniques. Auxiliary gas bottles are frequently used with piston accumulators to provide the required gas volume. Nominal volume: 1 qt. to 100 gal. 3000, 5000, and up to 15000 psi Flow Rate: up to 2000 gpm Request catalog # 02071832 Request catalog # 02071831 Request catalog # 02068597 Charging & Gauging To maintain system performance, HYDAC recommends a regular check of the gas precharge pressure. A loss in the gas precharge pressure will cause a drop in the system efficiency and could cause damage to the bladder, diaphragm or piston accumulator. By means of a charging and gauging unit, hydro-pneumatics accumulators are precharged with dry nitrogen or their existing gas precharge pressure is checked. For these purposes, a charging and gauging unit is connected to a commercially available nitrogen bottle via a flexible hose. The charging and gauging units incorporate a gauge, check valve in the charging connection, manual bleed valve and T-handle. Request catalog # 02071833 Copyright 1999 HYDAC TECHNOLOGY CORPORATION - Brochure - Accumulator Overview - #02068597 / 07.00 HYDAC CORPORATION 2280 City Line Road Bethlehem, PA 18017 Phone (610) 264-9503 Fax (610) 264-7529 www.hydacusa.com powerup@hydacusa.com