Service Instruction. Introduction of fuel injection pumps with tight governor control. Fig 1

Similar documents
UG-5.7, UG-8, UG10 Governor

SECTION 2.00 SPEED GOVERNING SYSTEM DESCRIPTION SPEED GOVERNING SYSTEM DESCRIPTION F18/H24 GOVERNOR

KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump

ENGINE GOVERNING SYSTEMS

PRODUCT SERIES: DPG-2100

Control of Heat Processes

Reference Manual. Governing Fundamentals and Power Management. This manual replaces manuals and Manual 26260

ESD5500E Series Speed Control Unit

Installation and Operation Manual. UG Dial Governor. UG-5.7/UG-8/UG-10 Dial. Manual (Revision E)

ESC2301. Universal Electronic Governor Controller Operation Manual

Self-Adjusting Clutch (SAC) Technology Special tools / User instructions

Woodward PSG Governor

ESD5550 / 5570 Series Speed Control Units

KT230 Series Caterpillar 3406 Governor System Installation Kit

EG3000. Generator Electronic Governor Controller Operation Manual

Installation Manual Installation Kit. for EPG 1712/1724 Electric Actuator on the Caterpillar 3208 Engine. Manual (Revision A)

AUTOMATIC CLUTCH Models

EG1069X. Generator Electronic Governor Controller Operation Manual

Product Manual (Revision D, 3/2000) Original Instructions. UG-5.7, UG-8, UG10 Governor. Installation Manual

ENGINE GOVERNING SYSTEMS

Westingh'ouse Steam Turbines-I. B (Rev. 3) GOVERNOR, GOVERNING VALVE

Hopkinsons Fig 9052 VALVE ACTUATOR


ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

TECHNICAL MANUAL OPERATOR S, UNIT, INTERMEDIATE (DS) AND INTERMEDIATE (GS) MAINTENANCE MANUAL FOR

Installation and Operation Manual. UG-5.7, 8, and 10 Lever Governor. Manual (Revision J)

ESD-5550/5570 Series - Speed Control Unit

GOVERNOR CONVERSIONS. 2301A and DRU replacement of EGA and MOP

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

KT145 Series John Deere 6076 with Nippondenso Inj. Pump

Engine Controls & Actuation

EG3002. Electronic Engine Governor Controller User Manual

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Installation and Operation Manual. PG-PL Governor. Manual (Revision P)

Application Information

DATE: April 5, 2005 SUPERSEDES: S.B. 373AR1 dated 2/26/99

Brake Upgrade Kit Fitting Instructions Bonneville America

Removal and Installation of Fuel Injection Pumps

1180, 1180DT, 1280, 1280DT, 1380, 1380DT, 1580, 1580DT, 1880 & 1880DT

ESD-5500E Series - Speed Control Unit

Heavy Duty Miniature Quick-Change Applicator (End-Feed Type) with Mechanical or Air-Feed Systems

Adjusting valve clearance

Chapter. Steering System Technology

ESD-5550/5570 Speed Control Unit. Manual

Hopkinsons Fig 9051 VALVE ACTUATOR

Product Manual (Revision B, 3/2014) Original Instructions. UG-15 Dial Governor. Installation and Operation Manual

10V. the rack of the oil pump must be on the

Product Manual (Revision L, 12/2014) Original Instructions. UG-5.7, 8, and 10 Lever Governor. Installation and Operation Manual

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

951B Traxcavator S/n 79H, 32F, 69H & 86J Volume 1 of 2

Product Manual (Revision G, 12/2014) Original Instructions. UG Dial Governor. UG-5.7/UG-8/UG-10 Dial. Installation and Operation Manual

LAND ROVER GROUP / Freelander I 2.0 Diesel / 09/ /2003 / Terrain vehicle Country of manufacture GB Cubic capacity/power 2.

Pneumatic-Pneumatic Positioner YT-1200L,R Installation manual

Repair Manual Ford DPS6 Gearbox. INA GearBOX

1983 BMW 320i. 1.8L 4-CYL 1983 Engines - 1.8L 4-Cylinder Engines - 1.8L 4-Cylinder

Fisher 657 Diaphragm Actuator Sizes and 87

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

TURBO-ALTERNATOR GOVERNING SYSTEMS

PED 5000 ELECTRIC ACTUATOR

MOTORS. Part 2: The Stepping Motor July 8, 2015 ELEC This lab must be handed in at the end of the lab period

Instruction. MI June E69F Current-to-Pneumatic Signal Converter

New Method for Improving On-Line Loading Rates on Mechanical Governors By Gerald G. Runyan

Illustrated Parts List to

HQ Series ¼ Turn Electric Actuator

Introduction. Types of Governors. The governors may, broadly, be classified as. 1. Centrifugal governors, and 2. Inertia governors.

DYNA Power Control Manual For Plus 1, Plus 2, Plus 4 and Plus 6 Ft. Lb. Systems

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

3161 Governor. Product Manual (Revision C) Original Instructions. Installation and Operation Manual

IGA225 Integrated Governor & Actuator

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

Operating and Maintenance Instructions for: Figure 79 Pneumatic Actuators (U/E options)

E Series. Automatic Engine Overspeed Shut Down Valves

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

2. RCV LEVER 1) STRUCTURE. 22 Hand coil 23 O-ring 24 Wiper seal 25 Plug 26 Boot retainer collar 27 Handle adapter 28 Nut 29 Nut 30 Insulation tube

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

MX431 Generator Automatic Voltage Regulator Operation Manual

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Finding Top Center Position for No. 1 Piston. Set The Top Center Position By Temporary Marks On Type 1 Engines and 9RM Engines

Main Governor and Speed Changer

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Operation & Instructions Manual SA 3 - SA 100 SAR 3 - SAR 100

SERVICE MANUAL Gearbox - Allison AT545 - Gearbox Installation

ST-125 Control System for Stanadyne DB-4 Series Pumps. Product Manual (Revision NEW) Original Instructions

2. Remove front wheels.

DATE: July 22, 2004 Supersedes: S.B. 60R6 dated June 24, 2004

walton TEMPERATURE CONTROL SYSTEMS Pneumatically Operated (Rotary)

Your G3 buggy is fitted with three switches on the front part of the body:

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

1 of 25 9/12/2013 9:07 PM

EDG5500 Electronic Digital Governor With Quikset Display

TLD 2500 Tube Testing Guns

Fisher 3024C Diaphragm Actuator

Product Manual (Revision B) Original Instructions. EPG Electrically Powered Governor Models 501 and Installation and Operation Manual

2006 MINI Cooper S GENINFO Starting - Overview - MINI

Fitting Instructions: Sprint ST (955i), Sprint RS & Tiger 955cc Heated Grip Kit

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

COMPETITION ENGINEERING. 80 Carter Drive P.O. Box 1470 Guilford, CT Phone: (203) Fax: (203)

1 Recommended tools. removing - refitting : timing belt INJECTION ES9J4. PAGE 1 - b1eg1bp0 - removing - refitting : timing belt. - Fig.

Transcription:

Service Instruction Note DIESEL SEP 2002 Based on UK DT319 (EN) SIN 508 DPG PUMPS (DPA) EQUIPMENT: SUBJECT: Pumps 3230F560T, 3349F250T, 3340F260T, 3260F530T and 3340F280T fitted to gen set and constant speed applications. First customer Wilsons gen sets equipped with Perkins engines. Introduction of fuel injection pumps with tight governor control. 1 2 3 4 6 5 Fig 1 1. INTRODUCTION The DPG fuel injection pump (Fig 1) is a variant of the DPA pump and has been designed specifically for generator sets and constant speed applications that require tight governor control. This note describes the principles of operation. The pump is designed to maintain class A governing for a much longer period of running than conventional DPA pumps. Furthermore, if after some time in service the performance moves outside limits, the pump can be adjusted externally on the engine to restore class A governing requirements, hence extending service life. Delphi Diesel Aftermarket 1624 Meijer Drive Troy, Michigan 48084 USA Tel: [1] 248.288.2000 Fax: [1] 248.280-8280 Delphi Diesel Systems

SIN 508 - Sep 02-2 of 8 The pump has three external setting screws (Fig 1): Speed set screw (3) Droop control screw (4) Overspeed protection screw (1) The pump has the following special features: Reduced wear mechanical governor Governing stabiliser Reduced governor hysteresis Droop control and adjustment (metering valve height) Over speed protection Provision to convert for use with an Electronic Governor (EG) using a Woodward LCS integral actuator/controller fitted by the customer. Four-screw fixing governor cover (5) (including a trapped seal) with screw mountings (6) for the EG device. NOTE: These features may not appear on all pump variants. Pumps are supplied to the customer with a plug in the actuator hole (2). The DPG pump will allow the customer to perform the following tasks on the engine: - external adjustment of the governor rate (droop). - external adjustment to compensate for wear to the governor components. - external adjustment to convert from 50 Hz @ 1500 rpm to 60 Hz @ 1800 (or vice versa).

SIN 508 - Sep 02-3 of 8 2. SPECIAL FEATURES 2.1 Reduced wear package (fig 2) Design and quality improvements have been made to the governor weights and cage (1). The standard thrust washer (2) is driven by the driveshaft at engine start up via a drive rubber (3) (elastomer ring clutch) located between the weight cage and the thrust washer. The thrust sleeve has also been modified to include hydrodynamic thrust bearing pads (4) to keep the thrust washer rotating. The thrust washer disengages from the drive rubber on run up. As a result of these additions, wear to the toes of the weights is reduced. Fig. 2 2.2 Governor stabiliser (fig 3) The governor stabiliser is an hydraulic damper fitted to the governor arm and minimises system oscillations (i.e. designed to tune out the instability of engine/alternator systems) and allows the setting of steeper governor pull-off without instability (i.e. smaller droops). It comprises a stabiliser body (2) and an antibacklash spring (4), attached to the governor arm by a circlip (5), into which is fitted a stabiliser piston (3) and a stabilising spring (6). One end of the spring is attached to a stud (7). This spring is in parallel to the main governor spring. A small orifice (1) in the body controls the damping effect. Fig. 3

SIN 508 - Sep 02-4 of 8 2.3 Hysteresis (fig 4) Hysteresis between governor pull-off and pull-on has been reduced by introducing an improved knife edged governor arm and control bracket assembly giving zero lift (1) at the pivot point and knife-edges. In addition there is the improved design of governor weights/cage and thrust sleeve arrangement (2) as described previously in 2.1. Fig.4 2.4 Droop control and adjustment (fig 5) The rate of governor pull-off, or the percentage speed difference between full load and no load is known as droop. Fig.5 An external adjustment arrangement sets the droop to the desired governor rate. It also allows adjustment to compensate for the effect of manufacturing tolerances on governor performance. In addition it provides a means for governor rate adjustment to compensate for any wear in the field. It comprises an external screw adjuster (1) that controls the height of the metering valve via a stop guide (3). The stop guide acts on the top of the metering valve (2) and enables fuel delivery adjustment. The fuel feed hole to the metering valve is square. To facilitate this feature, a sleeve (4) with a square filling port is fitted into the hydraulic head.

SIN 508 - Sep 02-5 of 8 Figures 5A and 5B explain the principle of setting the droop control characteristic. L = Load d = Short droop F = Frequency D = Long droop R = Rated Frequency A = Flow area for 100 % load delivery B = Metering valve arm no load position C = Metering valve arm 100 % load position 1 = Fixed Metering valve sleeve with square fill port for maximum sensitivity 2 = Droop adjuster up 3 = Droop adjuster down 4 = Metering valve slot up 5 = Metering valve slot down 6 = Square filling port (side view) Referring to Fig 5A With the droop adjuster up (2) (screwed out) a small change in governor spring load and thus a small rotation of the metering valve creates a large change in flow area (A), thus giving a short governor pull-off. Referring to Fig 5B With the droop adjuster (3) in the down position (screwed in) a larger metering valve rotation is required to produce the same change in flow area (A). This requires a larger load change on the governor spring, producing a longer governor pull-off.

SIN 508 - Sep 02-6 of 8 Setting the droop on the engine This is a brief description of the procedure the customer would follow for setting the droop on the engine. Fig 5C Fig 5D L = Load F = Frequency R = Rated Frequency Z = Zero Fuel A = Initial Droop B = Final Droop 1 = Droop screw out 2 = Throttle screw out 3 = Droop screw in 4 = Throttle screw in Setting less droop (Fig 5C) 1) Under no load, loosen the trunnion nut slightly and the throttle lever setting screw locknut, then turn the throttle lever setting screw (2) anticlockwise to give slightly less than the new droop frequency/speed. Lock the adjusting screw and trunnion nut. 2) Under full load, slacken the droop screw locknut, and then screw out the droop adjuster (1) to give the rated frequency/speed. Lock the adjuster. If fitted, set the over speed protection screw by winding it in until it just interferes with the full load frequency/speed (engine speed begins to drop), then back it off one flat and lock. Setting more droop (Fig 5D) Back off the over speed protection screw. 1) Under no load, loosen the trunnion nut slightly and the throttle lever setting screw locknut, then turn the throttle lever setting screw (4) clockwise to give slightly more than the new droop frequency/speed. Lock the adjusting screw and trunnion nut. 2) Under full load, slacken the droop screw locknut, and then screw in the droop adjuster to give the rated frequency/speed. Lock the adjuster. If fitted, set the over speed protection screw by winding it in until it just interferes with the full load speed, then back it off one flat and lock.

SIN 508 - Sep 02-7 of 8 2.5 Over speed protection (Fig. 6 and 6A) Some customer s alternators are fitted with an over speed trip device, and when fitted these are normally set to trip between 9% and 11% above rated speed. At engine start up a correctly set pump can cause up to 20% over speed and hence this could cause the over speed trip device to shut down the engine immediately after starting. Fig 6 The governor stabiliser operates over all of the travel of the governor arm, for dead travel as well as the travel that changes fuel delivery. This introduces a time delay before the governor responds to the over speed at start up that is not present under normal running. Limiting the dead travel by means of a stop screw reduces the over speed to below 10%. It comprises an external screw adjuster (1) that abuts a pin (3) attached to the governor arm. NOTE: The introduction of this screw affected the wear package, as there was no loading on the governor weights. An over speed spring (2) was added to the governor arm to apply a load to the thrust sleeve in order to hold the weights in on start-up. S C Fig 6A A = B = S = T = C = Over speed on start up Over speed protection device limits over speed on start-up Engine speed (rpm) Time Over speed trip device bottom limit

SIN 508 - Sep 02-8 of 8 2.6 Electronic conversion 1 2 Fig 7 The pump can be simply converted to electronic governing with the fitment of a Woodward LCS integral actuator/controller (Fig 7 Item 1) fitted by the customer. The integral design of the LCS means that no separate controller is required which reduces wiring harness complexity to a minimum. The LCS digital control ensures precise governing with multiple governing strategies e.g. isochronous load sharing, 50/60 Hz switching, auxiliary load sharing etc. The actuator is supplied with a speed signal (normally from a variable reluctance magnetic pickup monitoring flywheel teeth) which is monitored within the LCS control. If the speed signal from the engine does not match the pre-programmed speed, the LCS actuator moves the pump metering valve (via the linkage spring, which has been modified to accept the actuator lever) to increase or decrease fuel until the speed signal and the pre-programmed speed are equal. This process is repeated many times a second. For pumps equipped with the Woodward LCS integral actuator the mechanical governor is used as an over speed protection device in the event of an electronic governor failure. NOTE: The over speed protection screw (Fig 1 Item 1) is removed and the hole is plugged. The speed setting screw (Fig 7 Item 2) then functions as a backup overspeed setting. For Dismantling/Re-assembly and test procedures of DPG pumps refer to Service Instruction Note 509 (UK Note DT320)