Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Similar documents
Dycon Power Solutions

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Elmdene International Ltd

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

PSU EN54-4 Power Supplies

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

K25000 & KD25000 Series

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

Low Frequency Inverter. User Manual

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Installation Instructions

EC200 ELECTRONIC CONTROL SYSTEM

EC400 Power Control System

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Professional Wireless Products

EC225 Power Control System

Installation Instructions

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

DEEP SEA ELECTRONICS PLC

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Installation and Operation Instructions 10/04/13

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

NT-500 Technical Support Guide. For use by qualified company approved Technicians

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Emergency lighting units EM converterled

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

SDM72 Start on Demand Modules

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

SBC / 2140 / Stage Battery Charger User Manual

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

Emergency lighting units EM converterled

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

AC/DC Converter MBP250-2A13D13M

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

SUM340 SUMMATION BOARD

Installation and Operations Manual

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Car Battery Charger Instructions for Use

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Power Supply EL

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

GCU-10. Automatic Engine Control Unit Operators Manual

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Time Electronics DC Voltage Calibrator. Technical Manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

ZonePlus Z322 zone valve Installation and commissioning instructions

Product Data Sheet. Damper Interface. Features

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Sieve Shaker 200mm/300mm - 8/12 inch SV003

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

Phoenix Inverter

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Cart Power. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.

Chargestar T26 / T45. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

General Precautions. Personnel Precautions

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DC POWER SUPPLY ALIMENTATION C.C.

SPECIFICATIONS SR CHARGER

Installation Manual. 13.5Vdc 5A Series N645 MODELS : TPS13-5Si TPS13-5SiB TPS13-5SiBD TPS13-5SiBD-20

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

Emergency lighting units EM converterled

PSM72H Push-Button Start Module

Multi-Mover Charger for model L25

Product Installation Document

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

IMPORTANT SAFEGUARDS

Emergency lighting units EM converterled

Instruction Manual. Electrobloc EBL 40 B

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Emergency lighting units EM converterled

REVISED ATM72 Auto Transfer Module

18W Round LED Slimline Emergency Light

EC328 Power Control System

User s Manual. Automatic Switch-Mode Battery Charger

Transcription:

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies D1541 D1542 D1543 D1545 D1543-X-8 D1545-X-8 D1545-4BNC D154X Series 1A 2A 3A 5A 3A fitted with 8-way output splitter 5A fitted with 8-way output splitter 5A fitted with 4-way power splitter and 4 loop through BNC connectors Installation Mount the metal enclosure onto the wall. Connect the Live, Earth and Neutral terminals to an un-switched fused spur. Connect the tamper outputs to the control panel as appropriate (see control panel manuals for details). Connect the 12v power output to the system. Fit the battery. Switch on the and confirm that the green LED marked 230V AC is lit. External power supply () The power supply has a three-way terminal block for Live, Earth and Neutral connections, and is protected by a 20mm anti-surge fuse. Mains earth is isolated from the 0V output, although, when supplied boxed, mains earth is connected to the metal enclosure. Tamper output This voltage-free output is connected to the tamper switch. These terminals will be shorted when the tamper switch is closed. Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com - info@dyconpower.com

12V power output Terminal blocks are provided to connect to the system. The green 230V AC LED or orange standby LED indicates that the 12V is available from these terminal blocks. Auxiliary power supply (batteries) These power supplies are compatible with 7AH or 8AH Sealed Lead Acid or Gel batteries which are connected to the BATT terminals. The orange standby LED, marked with a battery symbol, indicates when AC power is off and power is being supplied by the batteries. If two batteries are used, they must be connected in parallel. Output protection The output is protected by resettable fuse. Should the output be overloaded and the fuse trip, the red fuse fault LED, marked with a battery symbol, will be lit. The fault can be reset by removing the short and re-applying power after a minute to allow the fuse to cool. Battery protection The batteries and electronic circuitry are protected against reverse polarity connection by a self resetting electronic fuse. D15X8 output splitter The D15X8 is designed to connect to any Dycon D154X Series ungraded power supply to provide up to 8 individually fused outputs. The D15X8 is supplied fitted with 8 fuses rated at ½ Amp, plus 2 fuses rated at 1 Amp in a spares bag. The installer may fit any combination of fuses, provided that the overall load does not exceed that provided by the power supply. Example: a D1543 could support outputs 1 to 6 = ½ A (3A in total) or a D1545 could support outputs 1 to 6 = ½ A and outputs 7 and 8 = 1A (5A in total). A red LED is provided for each output, which lights if the relevant fuse ruptures. In addition, a 9 th LED is provided which lights when the input voltage is present. A 2-way Molex connector is provided to connect a remote LED to indicate if ANY fuse fails. Individual fuse fail indicators Connector for remote global fuse fail indication Fuses Input voltage present indicator Fuse protected Outputs 12V input from power supply D15X4-BNC This splitter allows power to up to 4 cameras and loop through connections for signals. 2

Individual fuse fail indications Fuses Connector for remote global fuse fail indication Fuse-protected outputs 12v input from power supply Maintenance This unit is only to be used by qualified service personnel; there are no user serviceable parts. No maintenance is required other than routine periodic testing and replacement of the standby batteries. For further information on routine battery replacement, please contact your battery supplier or manufacturer. Specifications Power supply Type A, ungraded, Environmental Class 2 AC input voltage 230v +10% -15%, 50Hz ± 15% Output voltage 13.7 nominal Output ripple PP Less than 100mV (less than 0.7% @ 13.7v) Battery recharge time (1 x 7Ahr batt) Less than 72 hours Operating temperature range -10 C to +40 C Product part numbers PCB A box B box C box 1 Amp D1541-P D1541-A D1541-B D1541-C 2 Amp D1542-P D1542-A D1542-B D1542-C 3 Amp D1543-P D1543-A D1543-B D1543-C 5 Amp D1545-P D1545-A D1545-B D1545-C Fitted with 8 fused outputs 3 Amp -- D1543-X-8-A D1543-X-8-B D1543-X-8-C 5 Amp -- D1545-X-8-A D1545-X-8-B D1545-X-8-C Fitted with 4 BNC splitter 5 Amp -- -- D1545-4BNC-B D1545-4BNC-C 8-way splitter D15X8-SPLITTER 4 BNC splitter D15X4-BNC Sizes and weights PCB A size B size C size Size (h x w x d) mm 130 x 100 x 38 235 x 170 x 85 260 x 320 x 90 345 x 430 x 90 Weight (kg) 0.19 2.0 3.2 4.5 All units are fused in the 230V. The D154X Series power supply fuses require no user intervention. Layout D1541 3

Green AC ON LED Orange Battery Standby LED Layout D1542 / D1543 Green AC ON LED Orange Battery Standby LED 4

Layout D1545 Green AC ON LED Orange Battery Standby Fuse In case of problems, telephone Dycon Technical Support on +44 (0)1443 471 900, or email technical@dyconpower.com. 5