HIGH PERFORMANCE BUTTERFLY VALVE

Similar documents
YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

DOUBLE OFFSET BUTTERFLY VALVE

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Bray/McCannalok High Performance Butterfly Valve Operation and Maintenance Manual

Bray/Mckannalok Butterfly Valve Series 40/41/42/43/44/45 Installation Manual Technical Bulletin No Date: May 2004/Page 1 of 6

BRAY/MCCANNALOK EN HIGH PERFORMANCE BUTTERFLY VALVE

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

SERIES 54 PROXIMITY SENSORS

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

SERIES 54 PROXIMITY SENSORS

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

RESILIENT SEATED BUTTERFLY VALVES Technical Manual

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

BRAY / McCANNALOK. Wafer, Lug and Double Flange High Performance Valves

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

IOM Manual. IOM Manual. Series 76/77.

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

RESILIENT SEATED BUTTERFLY VALVES BRAY.COM

NYL Resilient Seated Butterfly Valves Operation and Maintenance Instructions

Your Global Flow Control Partner. Series 92/93 Pneumatic Actuators. Technical Manual

BUTTERFLY VALVE - WAFER FAF 3500

W-K-M Model MA-1 DynaCentric Butterfly Valve

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

Double Offset High Performance Butterfly Valve

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

25mm-500mm (1"- 20") SERIES 20/21 Wafer/Lug BUTTERFLY VALVES SANITARY AND CHEMICAL / RESILIENT SEATED. The High Performance Company

Installation, Operation and Maintenance Manual

DEMCO DEMCO RESILIENT SEATED BUTTERFLY VALVE. Installation, Operation and Maintenance Manual D I S T R I B U T E D V A L V E S DEM-RSBV-IOM

Cryogenic Wafer-Sphere Butterfly Valves

DEMCO Resilient Seated Butterfly Valve

CENTER LINE. INSTALLATION and MAINTENANCE INSTRUCTIONS RESILIENT SEAT BUTTERFLY VALVES MANUAL AND AUTOMATED

WKM Model MB DynaCentric High Performance Butterfly Valve

Railroad Ball Valves Series 5REB3

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

INSTALLATION & MAINTENANCE MANUAL

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES

VF Series High-Pressure, High-Temperature Butterfly Valves

Bray/McCannalok High Performance Butterfly Valves Technical Manual

Installation, Operation and Maintenance Manual for the HE Series

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

Installation, Operation, and Maintenance Manual

METAL SEATED NELDISC BUTTERFLY VALVES, SERIES L12

DEMCO Resilient-Seated Butterfly Valve

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Installation, Operation, and Maintenance Manual

Series 7000 & 9000 Ball Valves

Wafer-Sphere Butterfly Valves

Fisher 9500 Butterfly Control Valve

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Installation, Operation, and Maintenance Manual

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

NAF-Duball ball valves Maintenance and installation instructions List of spare parts

PROCESS DEVELOPMENT & CONTROL LLC 1075 MONTOUR WEST INDUSTRIAL PARK CORAOPOLIS, PENNSYLVANIA PHONE (724) FAX (724)

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

K815W, K815L, K830W, K830L, K860W, & K860L Wafer-Sphere Butterfly Valve. Installation, Maintenance and Operating Instructions

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Fisher TBX Hydro Plug Fixture

A. This Section includes general duty valves common to several HVAC piping systems.

NAF-Torex butterfly valves Maintenance and installation instructions List of spare parts

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

USER INSTRUCTIONS. Installation Operation Maintenance. Valtek Torex TX Control and shut-off valves. Butterfly Valves. Experience In Motion

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

CONTROLS RESILIENT SEATED BUTTERFLY VALVES 20/21, 22/23, 30/31, 3A/3AH, 31H, 31U, 32/33, 35/36, 36H. The High Performance Company

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

2-20 (50mm-500mm) SERIES 30/31 Wafer/Lug RESILIENT SEATED BUTTERFLY VALVES. The High Performance Company

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

K-LOK Installation, Operation, Maintenance and Troubleshooting

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Installation Operation Maintenance

Fisher DSV High Performance Digester Switching Valve

Before installation these instructions must be fully read and understood

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

The valves should be stored on a pallet or skid in a clean, dry warehouse. If the valves must be stored outside, the following apply:

TECHNICAL SERVICE MANUAL

Baumann 24000F Wafer Control Valve

Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

Product Catalogue Heavy Duty Valves

DOUBLE OFFSET BUTTERFLY VALVE

2"- 20" (50mm-500mm) series 30/31 Wafer/Lug. butterfly valves. resilient seated. The High Performance Company

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

Baumann Sanitary Diaphragm Angle and Inline Control Valve

GT-200 GATE VALVES PN16, Screwed end

Masoneilan* Varilog* MS Control Valve

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

JT SERIES ANGLE STEM TANK BOTTOM BALL VALVE DN25 DN150. Installation, Maintenance and Operating Instructions

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

Transcription:

BRAY/MCCANNALOK EN HIGH PERFORMANCE BUTTERFLY VALVE BRAY.COM THE HIGH PERFORMANCE COMPANY 1

TABLE OF CONTENTS 1.0 Definition of Terms........................................... 2 2.0 Introduction............................................... 2 3.0 Valve Indentification...........................................3 4.0 Installation................................................ 4 5.0 Maintenance............................................... 5 6.0 Stem seal replacement......................................... 6 7.0 Seat replacement............................................ 7 8.0 Disc and Stem replacement...................................... 8 9.0 Field adjustments........................................... 10 10.0 Figures..................................................11 For information on this product and other Bray products please visit us on our website www.bray.com 1

READ AND FOLLOW THESE INSTRUCTIONS SAVE THESE INSTRUCTIONS 1.0 DEFINITION OF TERMS WARNING CAUTION NOTICE indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potential situation which, if not avoided, may result in an undesirable result or state, including property damage. 2.0 INTRODUCTION 2.1 The Bray/McCannalok EN high performance butterfly valve combines the advantages of trunniontype ball valves with the easy operation, light weight, and low cost of butterfly valves. One basic design is suitable for a wide range of services, including oxygen, chlorine, sour gas, vacuum, and steam applications. 2.3 Additional information about Bray/McCannalok EN butterfly valves including application data, engineering specifications, and actuator selection is available from your Bray distributor or sales representative. 2.2 FEATURES INCLUDE: 2.2.1 Bubble tight shutoff provided throughout a wide range of operating conditions. 2.2.2 Suitable for both modulating and on/off services, the Bray/McCannalok EN butterfly valve is easily automated with your choice of manual operators, electric and pneumatic actuators, positioners, and controls. 2.2.3 External travel stop for preventing over-travel of disc in opening and closing. 2.2.4 Uninterrupted gasket sealing faces. 2.2.5 Extended neck body for providing pipe insulation clearance of 60mm. 2.2.6 Blind bottom body design up to DN 300. 2.2.7 Bearing seal for protecting bearings from particle ingress. 2

3.0 VALVE IDENTIFICATION 3.1 All Bray/McCannalok EN valves are provided with an identification tag with the following data printed on it: 3.2 The valves are also provided with a tag plate on the actuator mounting flange with the following data printed on it: F <XX> / <Y> <Z> Nm > F<XX>: Actuator mounting flange size as per ISO 5211 e.g. F07 > <Y>: Breakaway torque in Nm at a differential pressure of 3.5 bar (air or nitrogen) > <Z>: Maximum allowable stem torque in Nm F 07 / 60 300 Nm > P/N: Full part number of the valve assembly > S/N: Unique serial number of valve > TAG: Valve or instrument tag number provided by customer > DN: Valve size e.g. DN 150 > PN: Pressure rating of mating flange > TS: Maximum permissible temperature in degree Celsius ( C) > PS: Maximum permissible pressure in bar(g) at room temperature. > BODY: Material grade of body/seat retainer e.g. 1.4408, 1.0619 etc. > DISC: Material grade of disc e.g. 1.4408 > STEM: Material grade of stem e.g. 1.4542 > SEAT: Material of seat e.g. R-PTFE > SEAL: Material of stem seal e.g. PTFE > YEAR MFD: Month and year of manufacture MM/YY 3

4.0 INSTALLATION 4.1 The Bray/McCannalok EN valve is designed to be mounted between EN, DIN and JIS flanges. When the valve is open, the disc will extend into the pipe on both sides of the valve further on the body side than the seat retainer side of the valve. Piping must be large enough to allow the disc to clear the pipe. Table 1 shows the minimum pipe ID allowable. NOTICE For maximum service life, install the valve with the seat retainer upstream. Positive shutoff will be obtained with the valve in either position; however, installation with the seat retainer upstream will give longer service life, especially in erosive services. Table 1: MINIMUM INSIDE DIAMETER OF PIPE WITH THE RECOMMENDED CLEARANCE Valve Size Minimum Pipe ID (mm) PN 10 PN 16 PN 25 PN 40 DN 65 60.0 60.0 60.0 60.0 DN 80 74.5 74.5 74.5 74.5 DN 100 96.0 96.0 96.0 96.0 DN 125 124.5 124.5 124.5 124.5 DN 150 152.5 152.5 147.5 147.5 DN 200 203.0 203.0 196.5 196.5 DN 250 253.5 253.5 244.0 244.0 4.2 With the disc in closed position, carefully center valve between flanges. Guide holes (wafer-type valve) or tapped holes (lug-type valves) to match pipe flanges and assist in positive alignment. 4.3 Flange gaskets are not generally included in the scope of supply of Bray/McCannalok EN valves. Flange gaskets should conform to EN1514-1 flat seal with form IBC or form FF. 4.4 The standard lug-type valve can be used in end of line service (downstream dismantling) only in one direction. The seat retainer side of the valve should be mounted upstream. DN 300 303.5 303.5 290.5 290.5 DN 350 333.0 333.0 333.0 333.0 DN 400 376.5 376.5 376.5 376.5 CAUTION If handle or actuator has been removed do not rotate disc beyond full open or closed position this could cause damage to sealing surfaces. NOTE: Bray/McCannalok EN valves are equipped with external travel stops to prevent disc over-travel. The valve is opened by turning counter clockwise, closed by turning clockwise. The double D flats or keyway at the top of the stem is parallel to the disc edge. FLOW UPSTREAM 4

5.0 MAINTENANCE 5.1 Reasonable precautions should be taken before beginning work on the valve. Protective clothing, as required by the specific line fluid, should be worn. WARNING Before removing handle or the actuator from the valve, or before removing seat retainer from a valve in dead end service, close the valve and depressurise the line. 5.0 MAINTENANCE WARNING The stem is coupled to the external travel stop by which the disc over travel is prevented The external travel stop may hit or come very close to the top plate surfaces at the end of open and closed positions. The impact of this force can be quite high depending on the actuator speed of operation. Keep hand or fingers away from the travel stop while the valve is in operation. 5.2 The eccentric design of the Bray/McCannalok EN may allow line pressure to open the valve if the handle/ actuator is not in place while the valve is under pressure. 5.5 Begin all work on a valve that has been removed from the line by cleaning the valve, removing any grit or scale. WARNING Do not pressurise the line without an operator mounted on the valve. CAUTION If handle or actuator has been removed do not rotate disc beyond full open or closed position this could cause damage to sealing surfaces. 5.3 The Bray/McCannalok EN valve must be in the closed position to be removed from the line. 5.4 External travel stop is not for disc positioning. Travel stop prevents over-travel of disc in opening and closing. If the disc movement is restricted by the travel stop, the disc has overtravelled. 5.6 Replacement seats, seals and other parts are available from authorised distributors. Contact your distributor or sales representative for details of price and delivery. 5.7 When using a pipe whose ID is smaller than the recommended minimum inside diameter of pipe with adequate clearance, a chamfer of 45 should be provided on the end of the pipe so that it clears the disc. 5

6.0 STEM SEAL REPLACEMENT Table 2: TOTAL NUMBER OF STEM SEALS NOTICE Note assembly positions before removal. Valve Size PN 10 PN 16 PN 25 PN 40 DN 65 4 4 4 4 DN 80 4 4 4 4 DN 100 4 4 4 4 6.1 Refer Figure 1 (p.11) and Figure 2 (p.12) for parts identification. 6.2 If required, remove operator. Remove TOP PLATE SCREWS (220). Remove TOP PLATE (210). 6.3 Remove TRAVEL STOP SCREW (240) and TRAVEL STOP (230). DN 125 4 4 4 4 DN 150 4 4 4 4 DN 200 5 5 5 5 DN 250 5 5 5 5 DN 300 5 5 5 5 DN 350 6 6 6 6 DN 400 6 6 6 6 6.4 Remove KEY (250) if applicable. 6.5 Remove GLAND NUTS (170) and LOCK WASHERS (180). Remove GLAND RETAINER (140), RETAINING RING (150) and GLAND RING (130). NOTE: For valve sizes DN 350 through DN 400, remove the DISC SPRINGS (260) along with GLAND RING (130) 6.6 Hook out STEM SEALS (120). Do not remove WASHER (110), unless further valve disassembly is required. 6.9 Slide GLAND RING (130) over STEM (22) on top of STEM SEALS (120). Install RETAINING RING (150). Slide GLAND RETAINER (140) over stem and onto GLAND STUDS (160). Place LOCK WASHERS (180) and GLAND NUTS (170) on GLAND STUDS (160) and tighten finger tight. Tighten GLAND NUTS (170) evenly and alternately to the proper torque value given in Table 3. Table 3: GLAND NUT TIGHTENING TORQUES CAUTION During removal of the stem seals, care should be taken not to scratch stem or stuffing box bore. Valve Size 4D/4E Tightening Torque (N-m) 4F/4G 4H/4J 4K/4L PN 10 PN 16 PN 25 PN 40 6.7 Examine stuffing box bore and stem, clean as necessary to remove any corrosion or foreign matter before installing new seals. 6.8 Install new seals in stuffing box one at a time, TFE (white) seals first, with the carbon fiber ring at the top if applicable. Stagger seal ring joints 180 apart when installing. Tap each ring to bottom and compress the ring before installing next ring. Refer Table 2 for total quantity of seal rings in each valve. DN 65 7 7 7 7 DN 80 7 7 7 7 DN 100 7 7 7 7 DN 125 9 9 9 9 DN 150 9 9 11 11 DN 200 10 10 15 15 DN 250 16 16 18 18 DN 300 18 18 23 23 DN 350 29 29 29 29 DN 400 49 49 49 49 6

6.10 Install KEY (250) on STEM (22) if applicable. 6.11 Slide TRAVEL STOP (230) over STEM (22) and tighten TRAVEL STOP SCREW (240). 6.12 Install TOP PLATE (210) while ensuring the TRAVEL STOP (230) orientation is correct. 6.14 Remount operator. 6.15 Operate valve open and close several times to check for binding and to set the stem seals. Loosen GLAND NUTS (170) and then proceed to retighten to the torque valves stated in Table 3. 6.13 Tighten the TOP PLATE SCREWS (220) to torque value given in Table 4. Table 4: TOP PLATE SCREW TIGHTENING TORQUE Tightening Torque (Nm) Valve Size 4D/4E 4F/4G 4H/4J 4K/4L PN 10 PN 16 PN 25 PN 40 Screw Torque Screw Torque Screw Torque Screw Torque DN 65 M8 15 M8 15 M8 15 M8 15 DN 80 M8 15 M8 15 M8 15 M8 15 DN 100 M8 15 M8 15 M8 15 M8 15 DN 125 M8 15 M8 15 M10 30 M10 30 DN 150 M8 15 M8 15 M10 30 M10 30 DN 200 M10 30 M10 30 M12 50 M12 50 DN 250 M12 50 M12 50 M12 50 M12 50 DN 300 M12 50 M12 50 M20 245 M20 245 DN 350 M20 245 M20 245 M20 245 M20 245 DN 400 M20 245 M20 245 M20 245 M20 245 7.0 SEAT REPLACEMENT WARNING Do not pressurise the line without an operator mounted on the valve. 7.1 Refer Figure 1 (p.11) and Figure 2 (p.12) for parts identification. 7.2 With the DISC (21) in the closed position, remove the valve from the line 7.3 Lay the valve down with the DISC (21) in the closed position and the seat retainer side facing up. 7.4 Remove the RETAINER PLATE SCREWS (60), RETAINER PLATES (50), SEAT RETAINER (40), and SEAT (30). 7.5 Carefully clean the seat area in the BODY (10) ). Remove foreign material, dirt, etc. Check disc seating area for nicks or scratches. 7.6 With the DISC (21) is in the CLOSED position, place the new SEAT (30) on DISC (21), carefully centering it in the recess in the BODY (10). 7.7 Carefully place the SEAT RETAINER (40) in position on top of SEAT (30). 7.8 Slide in the RETAINER PLATES (50) into the groove on the SEAT RETAINER (40) and align the countersunk holes to the tapped holes on the BODY (10). 7.9 Lightly grease the threads and install the RETAINER PLATE SCREWS (60). 7

8.0 DISC AND STEM REPLACEMENT WARNING Before removing handle or the actuator from the valve, or before removing seat retainer from a valve in dead end service, close the valve and depressurise the line. Do not pressurise the line without an operator mounted on the valve. 8.1 Refer Figure 1 (p.11) and Figure 2 (p.12) for parts identification. 8.7 Remove the RETAINER PLATE SCREWS (60), RETAINER PLATES (50), SEAT RETAINER (40), and SEAT (30). 8.8 Turn DISC (21) to the full open position and drill out tack welds on large end of TAPER PINS (23). Drill sizes to remove tack welds are given in Table 5. CAUTION Take care to support valve so that disc surfaces are not scratched. NOTICE Table 5: DRILL SIZE TO REMOVE TACK WELD Stem and disc are supplied as a matched set with taper pins and are to be replaced as a set. Valve Drill Size (mm) 4D/4E/4F/4G PN 10/PN 16 4H/4J/4K/4L PN 25/PN 40 8.2 Remove handle assembly/gear box/actuator. Remove TOP PLATE SCREWS (220). Remove TOP PLATE (210). 8.3 Remove TRAVEL STOP SCREW (240) and TRAVEL STOP (230). 8.4 Remove KEY (250) if applicable. NOTICE Note assembly positions before removal. DN 65 4 4 DN 80 4 4 DN 100 4 4 DN 125 4.5 4.5 DN 150 4.5 5 DN 200 5.5 6.5 DN 250 6.5 8 DN 300 8.5 12.5 DN 350 12 12 DN 400 12 12 8.5 Remove GLAND NUTS (170) and LOCK WASHERS (180). Remove GLAND RETAINER (140), RETAINING RING (150) and GLAND RING (130). NOTE: For valve sizes DN 350 through DN 400, remove the DISC SPRINGS (260) along with GLAND RING (130) 8.6 Hook out STEM SEALS (120). CAUTION When removing stem seals, care should be taken not to scratch stem or stuffing box bore. NOTE: Use center-punch to dimple center of tack welds prior to drilling. 8.9 Place valve in flat position, with flat face of disc up. Support disc and body on wooden blocks to protect disc and body surfaces. Disc will rest in partially open position. 8.10 Knock out TAPER PINS (23) using a rod or punch on small end of pin (opposite tack weld). It may be necessary to lift body and rotate disc slightly to do this. Make sure disc is resting on wood block since it will swing freely on stem with pins removed. When TAPER PINS (23) are removed, lay body down so disc and body are evenly supported on flat surface. 8

Valve sizes DN 200 through DN 300 has an M6 tapped hole on the top face of the stem which can be used to attach an eye bolt to pull out the stem. 8.11 Valve sizes DN 65 to DN 300 has a blind bottom body. So the STEM (22) needs to be pulled out from the top side of the valve. After long or severe service this may take considerable force. Be careful not to damag e bearings, spacers or body. NOTE: To make stem disassembly easier, the GLAND RETAINER (140) can be inserted in reverse direction over the stem with the counter bore facing towards the top face of the STEM (22) and placing the RETAINING RING (150) or SPLIT RINGS between the stem and gland retainer. The gland retainer can then be pulled outwards which will transfer the force to the stem through the retaining ring. 8.12 For Valve sizes DN 350 to DN 400 perform the following steps. 8.12.1 Remove the BOTTOM PLATE NUTS (320), BOTTOM PLATE (300), WAVE SPRING (280), DISC SUPPORT (270) and GASKET (290) from the bottom side of BODY (10). 8.12.2 Using a brass bar or drift punch, knock STEM (22) loose and pull from BODY (10). After long or severe service this may take considerable force. CAUTION When removing stem seals, care should be taken not to scratch stem or stuffing box bore. 8.13 DISC SPACERS (70) are used at top and bottom of DISC (21) to properly position disc in BODY (10). Proper spacers were selected at initial assembly and rarely require replacement. The location of these spacers should be noted, and the spacers marked at disassembly so that they are reinstalled in the same positions, top and bottom. 8.14 Separate BODY (10) from DISC (21), and remove WASHER (110) from packing bore. 8.15 oved from body, note position and mark to reinstall in same location. If bearing liner is worn through to the shell, or severe damage is evident they should be replaced. Replacement is rarely needed. 8.16 Clean BODY (10) thoroughly to remove all dirt, foreign matter, rust, etc. 8.17 Place the BODY (10) flat, seat retainer side up, and support it on wooden blocks sufficiently above the work surface as to facilitate insertion of the DISC (21) in open position. 8.18 nstall the DISC SPACERS (70) in to the body stem bore making sure that spacers are returned to original locations as marked in step 8.13 8.19 Lower the disc into position, aligning the bores in BODY (10) and DISC (21). 8.20 Insert new STEM (22) in BODY (10) with large end of the taper pin holes toward the top. 8.21 Align taper pin holes in disc and stem, and install TAPER PINS (23). Drive pins in tightly with rod or punch, and tack weld each pin to DISC (21) at large end of pin. 9

8.22 For Valve sizes DN 350 to DN 400 perform the following steps. 8.22.1 Install new GASKET (290) in to the groove on the bottom face of BODY (10). 8.22.2 Install DISC SUPPORT (270), WAVE SPRING (280) and BOTTOM PLATE (300) 8.22.3 Tighten BOTTOM PLATE NUTS (320) to torque Valve Size mentioned in Table 6. Table 6: BOTTOM PLATE TIGHTENING TORQUE 4D/4E Tightening Torque (Nm) 4F/4G 4H/4J 4K/4L PN 10 PN 16 PN 25 PN 40 DN 350 11 11 11 11 DN 400 16 16 16 16 8.23 Install new STEM SEALS (120), following instructions in section 6.0 STEM SEAL REPLACEMENT 8.24 Install new SEAT (30), following instructions in section 7.0 SEAT REPLACEMENT 8.25 Remount handle operator, and operate valve several times to verify proper operation. Examine disc and seat for any damage before reinstalling in line. 9.2 Adjusting Valve Closure Valves with gear actuators or electric/pneumatic actuators may require adjustment of the travel stops in the actuator to properly close valve for tight shut-off. The following procedure should be followed to set travel or limit stops. (It is recommended that the valve must be removed from line for this procedure and actuator mounting). 9.2.1 Using a straight-edge and Vernier or depth caliper, measure the distances from the face of the SEAT RETAINER (40) to the DISC (21) (valve closed) face at the 3 o clock and 9 o clock positions (stem is at 12 o clock position). The measurements must agree within 1.5mm.. 9.2.2 If they do not agree, DISC (21) must be rotated in the direction of the larger dimension. If the 3 o clock dimension is larger, the disc is not fully closed, and must be rotated in the close direction more. If 9 o clock dimension is larger, disc is overclosed, and must be opened slightly. 9.2.3 he valve DISC (21) is at the full open position when the disc is perpendicular to the BODY (10). Set the open actuator stop for this position. 9.2.4 On gear operators, loosen and adjust the closing stop screw to permit proper disc positioning. Adjust and lock down when disc closure is within measured tolerance in Step 9.2.1. Open and close valve; recheck measurements before reinstalling in line. 9.0 FIELD ADJUSTMENTS 9.1 Stem Seal Leakage Should leakage occur at the stem seals, it may be stopped by retightening the GLAND NUTS (170) to the values specified in Table 3. NOTE: If the leakage cannot be stopped by this action, the stem seals require replacement. NOTICE Do not overtighten gland nuts, as this may cause increased operating torque and improper valve operation or closure. NOTICE The setting of the actuation device s close travel stop is important. The valve has an external travel stop to ensure valve disc cannot be over closed or opened. To ensure that the valve travel stop is not damaged, the actuator close travel stop bolt must be at a position just before valve disc contacts it s travel limiter. 9.2.5 For other power actuators, consult the manufacturer s instructions for setting travel stops, as these vary with actuator model and type. 9.2.6 If removing the valve from the line is not practical, as a crude remedy the disc can be placed into a position in the seat at which the leakage stops and travel stops are adjusted to this position. 10

10.0 FIGURES Figure 1: DN 65 DN 300 Item Qty. Description 10 1 Body 220 21 1 Disc 22 1 Stem 210 23 2 Pin, Disc-Stem 200 192 180 230 240 170 160 30 1 Seat 40 1 Seat Retainer 50 2 Retainer Plate 60 4 Retainer Plate Screw 70 2 Disc Spacer 80 2 Bearing 22 140 150 130 90 1 2 Bearing Seal 100 1 Packing Spacer 110 1 Washer 120 110 120 1 Stem Seal 130 1 Gland Ring 140 1 Gland Retainer 100 150 1 Split Ring 160 2 Gland Stud 23 80 30 21 10 90 70 70 90 80 190 200 40 60 50 Item Qty. Description 170 2 Gland Nut 180 2 Gland Washer 190 1 Indentification Tag 192 1 Torque Tag 200 6 Drive Screw 210 1 Top Plate 220 4 Top Plate Screw 230 1 Travel Stop 240 1 Travel Stop Screw 1) Bearing Seal is available as an option 11

10.0 FIGURES Figure 2: DN 350 DN 400 220 200 192 180 210 230 170 240 Item Qty. Description 10 1 Body 21 1 Disc 22 1 Stem 160 23 2 Pin, Disc-Stem 250 140 150 260 130 30 1 Seat 40 1 Seat Retainer 50 4 Retainer Plate 60 4 Retainer Plate Screw 22 23 120 130 100 80 70 70 2 Disc Spacer 80 2 Bearing 90 1 2 Bearing Seal 100 1 Packing Spacer 110 1 Washer 120 1 Stem Seal 130 2 Gland Ring 140 1 Gland Retainer 10 150 1 Split Ring 160 4 Gland Stud 30 21 190 200 170 4 Gland Nut 180 4 Gland Washer 190 1 Indentification Tag 192 1 Torque Tag 200 4 Drive Screw 210 1 Top Plate 220 4 Top Plate Screw 40 50 60 70 80 270 280 290 300 310 320 230 1 Travel Stop 240 1 Travel Stop Screw 250 1 Key 260 2 Disc Spring 270 1 Disc Support 280 1 Wave Spring 290 1 Gasket 300 1 Bottom Plate 310 4 Bottom Plate Stud 320 4 Bottom Plate Nut 1) Bearing Seal is available as an option 12

THE HIGH PERFORMANCE COMPANY LOCAL BRAY CONTROLS (UK) LIMITED Subsidiary of Bray International, Inc. 16-18 Fountain Crescent Inchinnan Business Park Inchinnan PA4 9RE Scotland T. +44 141 812 5199 F. +44 141 812 6199 bcuk.sales@bray.com www.bray.com BRAY INTERNATIONAL PRIMARY SALES AND SERVICE LOCATIONS AFRICA Johannesburg CHINA Hangzhou, Zhejiang MEXICO Zapopan, Jalisco SOUTH KOREA Seoul AUSTRALIA Melbourne COLOMBIA Bogotá MIDDLE EAST Dubai SOUTHEAST ASIA Malaysia BENELUX Heerhugowaard FRANCE Voiron PERU Lima UNITED KINGDOM Glasgow BRAZIL Paulinia, Sao Paulo GERMANY Krefeld POLAND Oświęcim USA Houston, Texas CANADA Montreal INDIA Vadodara RUSSIA Moscow CHILE Santiago ITALY Milano SINGAPORE Ubi Techpark FLOW-TEK RITE CORPORATION AMRESIST KUGELHAHN MÜLLER BRAZIL Paulinia, Sao Paulo CANADA Montreal USA Houston, Texas GERMANY Krefeld CHINA Hangzhou, Zhejiang VALVTRONIC BRAY/VAAS USA Houston, Texas ARGENTINA Buenos Aires INDIA Chennai All statements, technical information, and recommendations in this bulletin are for general use only. Please contact us for the specific requirements and material selection for your intended application. The right to change or modify product design or product without prior notice is reserved. Patents issued and applied for worldwide. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. OM-BrayMcCannalok-EN_EU-EN_2017-10-19 HEADQUARTERS BRAY INTERNATIONAL, INC. 13333 Westland East Blvd. Houston, Texas 77041 T. +1 281.894.5454