McQuay Air-Cooled Reciprocating Chiller ALR

Similar documents
McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

Daikin McQuay. Air- Cooled Condenser. ACH, ACX, ACL Vintage A. Replacement Parts List No Revision C 10/2016

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay Climate Control Singer

McQuay Westinghouse. Centrifugal Chiller PF, PFH 063. Last Manufactured: Replacement Parts List No Revision AB 06/2018

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

McQuay Westinghouse. Centrifugal Chiller PE, PEH 126 PE Last Manufactured: Replacement Parts List No Revision AB 04/2016

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay Westinghouse. Centrifugal Chiller PEH, PH, PHH 046, 050 PE 046, 047, 048, 050 PF 083, 096, 105, 116. Last Manufactured: 2002

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay Westinghouse. Centrifugal Chiller PEH 087. Last Manufactured: Replacement Parts List No Revision AA 04/2016

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller WMC 035T. Last Manufactured: Replacement Parts List No Revision J 12/2017

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

Note: Supplemental pages added for CE100M Compressor. See Index

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

McQuay. Magnitude Water-Cooled Magnetic Bearing Centrifugal Chiller. WMC 150 Vintage A. Last Manufactured: 2005

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay Centrifugal Chiller PEH, TEH

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

McQuay Westinghouse. Centrifugal Chiller PFH 087. Last Manufactured: Replacement Parts List No Revision P 04/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

LUI / LUO. Condensing Units

McQuay. SeasonMaster Central Station Air Handler. HSH, HMH, HWL Vintage B Vintage C. Last Manufactured: 1984

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

McQuay. Magnitude Magnetic Bearing Centrifugal Chiller. WMC 400DSC Vintage A. Replacement Parts List No Revision F 10/2017

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay Air Cooled Chiller AWS175A, AWS190A, AWS210A, AWS230A, AWS250A AWS280A, AWS300A, AWS320A, AWS350A, AWS380A, AWS405A PL

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

Daikin McQuay. Global Scroll Compressor Air-Cooled Chiller. AGZ Vintage D Unit Revision 00, 0A (Code 55)

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

Air Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

Centrifugal Chiller PFH087 PL

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

Eclipse 2000 Service Parts

McQuay. Global Air-Cooled Screw Compressor Chiller. AGS (60 Hertz) (50 Hertz) Vintage B. Last Manufactured: 2008

SeasonPak Packaged Air-Cooled Water Chiller

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage F. Replacement Parts List No Revision G 04/2018


ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

RCD Air Cooled Condensing Unit (50/60 Hz)

Centrifugal Chiller PEH087 PL

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

Daikin Daikin McQuay. Magnitude Water-Cooled Magnetic Bearing Chiller. WMC 400 Vintage B. Replacement Parts List No Revision J 10/2017

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

McQuay Central Station Air Handler Medium Pressure MSL

Transcription:

Replacement Parts List No. 057115200 Revision S 07/2015 McQuay Air-Cooled Reciprocating Chiller ALR Sizes 010-185 Vintage D Last Manufactured: 2000 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Page(s) Heading Description Index 2, 3 Index 4 Revision History Parts List Revisions 5-7 Nomenclature Unit Serial Number and Unit Model Number Definitions 8-26 Compressors 8 Information Arrangements, Power Factor Correction Capacitors 9 Components Unloaders, Crankcase Heaters, Motor Protectors, Flange Assembly for Oil Equalization 10 Unit Compressors 010D - 016D 11 Unit Compressors 020D - 025D 12 Unit Compressors 030D 13 Unit Compressors 035D - 050D 14 Unit Compressors 060D - 070D 15 Unit Compressors 085D 16 Unit Compressors 100D 17 Unit Compressors 110D 18 Unit Compressors 120D 19 Unit Compressors 130D 20 Unit Compressors 135D 21 Unit Compressors 145D 22 Unit Compressors 150D 23 Unit Compressors 165D 24 Unit Compressors 170D 25 Unit Compressors 185D 26 Mounting Components All Sizes 27-29 Control & Power Panel 010D - 016D 27 Diagram 010D - 016D 28, 29 Components 010D - 016D 30-63 Power Panel 30 Diagram 020D - 030D 31 Components 022C 32 Components 025C 33 Components 030C 34 Diagram 035D - 070D 35 Components 035D 36 Components 040D 37 Components 050D 38 Components 060D 39 Components 070D 40 Diagram 085D - 185D 41, 42 Components 085D 43, 44 Components 100D 45, 46 Components 110D 47, 48 Components 120D 49, 50 Components 130D 51, 52 Components 135D 53, 54 Components 145D 55, 56 Components 150D 57, 58 Components 165D 59, 60 Components 170D 61, 62 Components 185D 63 On/Off Switch, Alarm Bell. Signal Converter Components 64-87 Control Panel 64 Volt/Amp Meter Complete Assembly and Components 65 Diagram Electromechanical Panel 020D - 030D 66 Components Electromechanical Panel 020D - 030D 67 Diagram Electromechanical Panel 035D - 070D, Left Side 68 Components Electromechanical Panel 035D - 070D, Left Side 69 Diagram Electromechanical Panel 035D - 170D, Right Side 70 Components Electromechanical Panel 035D - 170D, Right Side 71 Diagram Electromechanical Panel 085D - 185D, Left Side 72 Components Electromechanical Panel 085D - 185D, Left Side 73 Diagram Electromechanical Panel 085D - 185D, Right Side 74 Components Electromechanical Panel 085D - 185D, Right Side 75 Main Capacity Controller Electromechanical Panel 020D - 185D, Honeywell Controller W7100 76 Main Capacity Controller Electromechanical Panel 020D - 185D, Johnson Controls Controller UNT 77 Diagram MicroTech Panel 035D - 070D, Left Side 78 Components MicroTech Panel 035D - 070D, Left Side 79 Diagram MicroTech Panel 035D - 070D, Right Side 80 Components MicroTech Panel 035D - 070D, Right Side Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 2

Index, Continued Page(s) Heading Description 81 Components MicroTech Panel 035D - 070D, Keypad, Start Counters, Hour Meters 82 Diagram MicroTech Panel 085D - 185D, Left Side 83 Components MicroTech Panel 085D - 185D, Left Side 84 Diagram MicroTech Panel 085D - 185D, Right Side 85 Components MicroTech Panel 085D - 185D, Right Side 86 Components MicroTech Panel 085D - 185D, Keypad, Start Counters, Hour Meters 87 Cables, Sensors, Wells MicroTech Panel, 035D - 185D 88 Gauges 88 Components All Sizes 89-110 Condenser Fan Section 89 Diagram 010D - 016D 90 Components 010D - 016D 91 Diagram 020D - 030D 92 Components 020D - 030D 93 Diagram 035D 94 Components 035D 95 Diagram 040D 96 Components 040D 97 Diagram 050D - 060D 98 Components 050D - 060D 99 Diagram 070D 100 Components 070D 101 Diagram 085D - 100D 102 Components 085D - 100D 103 Diagram 110D 104 Components 110D 105 Diagram 120D - 145D 106 Components 120D - 145D 107 Diagram 150D 108 Components 150D 109 Diagram 165D - 185D 110 Components 165D - 185D 111-116 Cabinet 111 Components 010D - 016D 112 Components 020D - 030D 113 Components 035D - 110D 114 Coil Guards 035D - 100D 115 Components 120D - 185D 116 Coil Guards 110D - 185D 117-136 Piping Components 117 Basic Information Circuiting Diagrams and Notes 118 Components 010D, 013D 119 Components 016D, 020D 120 Components 025D - 030D 121 Components 035D 122 Components 040D 123 Components 050D 124 Components 060D 125 Components 070D 126 Components 085D 127 Components 100D 128 Components 110D 129 Components 120D 130 Components 130D 131 Components 135D 132 Components 145D 133 Components 150D 134 Components 165D 135 Components 170D 136 Components 185D 137-139 Evaporator 137 Complete Assemblies All Sizes 138 Components 035D - 185D 139 Plate Exchangers Insulation, Thermostat, Heaters 140 Condenser 140 Condenser Coils All Sizes- Part Numbers and Locations 141 Vibration Isolators 141 Part Numbers, Locations All Sizes CPL1-CPL3 Critical Parts List Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 3

Parts List Revision History Rev. Date Description New 2/99 Status change from "2nd Draft Copy" to "New". Page 76 - Added 34-Conductor Ribbon Cable (Ref.# 906). Page 80 - Added Bubble # 906. Page 81 - Added 34-Conductor Ribbon Cable (Ref.# 906). A 9/99 Page 2 - Corrected Table of Contents information for page 7. Page 7 - Added part number for Flange Assembly for Oil Equalization. Page 72 - Added part number for R8 Relay. Page 85 - Cables & Sensors: Re-formatted page to correct various part numbers. Pages 110 & 111 - Added information for Key for Control Panel Door Lock (Ref.# 896). B 12/99 Pages 55, 57 & 59 - Updated information for Fuses F7 and F9 on 208/230V. Page 56 - Corrected description for 90 FLA Contactor, part number 027514407. Page 74 - Corrected description for Main Controller to "CP1". Pages 90,92,94,96,98,100,102,104,106 & 108 - Added footnote for Motor Capacitor. C 8/00 Page 7 - Added 300 PSI Relief Valve pn 735045850. Page 68 -Bub. #65 pn corrected, was # 020410000 and is now #030410000. Page 72 - Bub. #65 pn corrected, was # 020410000 and is now #030410000. Page 76,81-Bub #902, added fuses; Input Power #065822001 & Comm Port #065821901. Page 78,83 - Bub #900, Output Board Fuse, 5A; pn 066402901. Page 135 - Added: NOTE: See ALR 'E' if flanges are needed for replacement. D 6/01 Page 110- Bub. #900 part number changed from 055361201 to 055361203. E 9/01 Page 64-Schematic symbol TD4; added '(until approx. 1993)' to description of #028210108, added another TD4-TSB413 with pn 735005944 (1993 and newer). F 10/01 Page 73 - Added part #048442405 to bub. #650;Control Sensor w/30 ft., 18 awg. cable. Added "with 15 ft., 22 awg. cable" to descrip. of bub. #650-pn 048442402. G 4/02 Page 112 - Sizes changed to 035D-100D (was 035D-110D). Page 114 - Sizes changed to 110D-185D (was 120D-185D). H 07/02 Page 7 - Removed "incl. site glass' from desc. of Flange Ass'y for Oil Equaliz. #049122701. I 09/02 Page 96 -Added 2 notes; *SPEEDTROL MOTORS ARE O.D.P. 1-PHASE MOTORS ONLY & **T.E. MOTORS ARE ALWAYS 3-PHASE & NEVER USED IN A SPEEDTROL OPTION. Removed O.D.P. from totally Encl.heading. Deleted Bub.700 from the T.E. group of motors. J 09/02 Pgs. 90,92,94,98,100,102,104,106,108-Added same changes as in Rev. I (see above rev.) K 10/02 Page 106,108 - Bub. #708; Fan Prop 28" p/n 072941301 was changed to p/n is 072941302. L 5/03 Page 137-Htr Ref #54 ALR 035D-085D part # was changed from 735074719 to 735079719. M 5/03 Page 107-Bubbles 700 and 701 switched on diagram. N 4/2005 Pages 9-23 - Removed all copeland compressor information. O 3/2006 Pages 33,37,39,41,43,45,47,49,51,53,55,57,59 - Added notes to DSI Disconnect Switch. Pages 66,68,70,72 - Added *** note to Freezestat (FS1) Pages 106&108 - MOTORS; changed 'ODP' motors to 'Standard' motors, removed TE Motor information, Bubbles 700 & 701 no longer has references to ODP (Open Drip Proof), added ' ****' Note refering to p/n 330423401 that was previously 072937601. P 12/08 Page 138 - Change Aluminum Fin Coil 110D Position Three p/n 058366850 to 058368850. Q 10/09 Updated Cover and Revision pages with current logo design. Pages 65 & 69- Changed Bub # for R13 to 5 from 6 and R21 from 7 to 6. Pages 66 & 70- Added TB4 p/n 0159918124 and TB5 p/n 022431214. Page 90- Added quantity of 3 and description to Units with Optional TE motors. Page 92 & 94- Added quantity of 4 and description to Units with Optional TE motors. Page 96 & 98- Added quantity of 6 and description to Units with Optional TE motors. Page 100 & 102- Added quantity of 10 and description to Units with Optional TE motors. Page 104- Added quantity of 12 and description to Units with Optional TE motors. Pages 95, 99, 103, & 105- Reversed the Bub descriptions to match the corresponding table. Page 111- Deleted Ref # 901 p/n 046739301. Page 113- Added Ref # 887 p/n 071698801. Page 136- Corrrected Head Bolt Bub number from 355 to 353. R 06/11 Pages 76 & 81 - Correct MT Controller part number to 065487306 (was 065487311). S 07/15 Pages 6 & 7: Added pages for Complete Model Nomenclature. Page 90: Corrected part # for 575V Motor, was 073002201. Pages 92,94,96,100,102,104,106: Corrected description for T.E. Motor, was ODP. CPL1-3: Added pages for Critical Parts List. Daikin Applied 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 4

Nomenclature Serial Number and Stock Unit Serial Number Until 1994 5 ZA 12345 00 Factory 5= Staunton,VA Engineering Revision Serial Number Year and Month of Manufacture: Year Month Z= 1994 A= Jan B= Feb. C= Mar D= Apr. E= May F= Jun G= Jul H= Aug J= Sep. K= Oct. L= Nov. M= Dec. Stock Unit Model Number ALR 035 D 12 Vintage Voltage 12 = 208/230V 27 = 460V 42 = 208/230V Nominal Tonnage ex. 040 = 40 Tons Unit Type: ALR= Air- Cooled Accessible Hermetic Compressor Chiller Serial Number 1995- Current 5 5A 12345 00 Factory 5= Staunton,VA Engineering Revision Serial Number Year and Month of Manufacture: Year Month 5= 1995 A= Jan. 6= 1996 B= Feb. 7= 1997 C= Mar. 8= 1998 D= Apr. 9= 1999 E= May F= Jun G= Jul H= Aug J= Sep. K= Oct. L= Nov. M= Dec. Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 5

Nomenclature Complete Unit Model Number ALR 110D 5 27 PW D C 04 Y Y MYY Y Y Y Y S1 A F 11 1 Y A E 1 EYA 44 Y Code 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 28 30 Code 02 Size (in nominal tons) / Vintage 010D= 10 Tons 085D= 85 Tons 013D= 13 Tons 100D= 100 Tons 016D= 16 Tons 110D= 110 Tons 020D= 20 Tons 120D= 120 Tons 025D= 25 Tons 130D= 130 Tons 030D= 30 Tons 135D= 135 Tons 035D= 35 Tons 145D= 145 Tons 040D= 40 Tons 150D= 150 Tons 050D= 50 Tons 165D= 165 Tons 060D= 60 Tons 170D= 170 Tons 070D= 70 Tons 185D= 185 Tons 03 Refrigerant Type Y= R22 5= R134a 04 Electrical 12= 208V/60Hz/3Ph 29= 230V/60Hz/3Ph 42= 208-230V/60Hz/3Ph 27= 460V/60Hz/3Ph 37= 575V/60Hz/3Ph 28= 380/V50Hz/3Ph 44= 415V/50Hz/3Ph 05 Starting Options AL= Across-the-Line Start PW= Part Winding Start 06 Power Connection Options P= Single Point Power Block D= Unit Mounted Non-Fused Disconnect Switch M= Multiple Point Power Supply 07 Compressor Short Circuit Protection Y= Not Required C= Circuit Breakers 08 Capacity Control 02= 2 Step Capacity Control 03= 3 Step Capacity Control 04= 4 Step Capacity Control 06= 6 Step Capacity Control 08= 8 Step Capacity Control 09 Hot Gas Bypass Y= Not required 1= Hot Gas Bypass Control, Circuit 1 2= Hot Gas Bypass Control, Circuit 1 & 2 10 Control Circuit Transformer Y= Not Required A= Control Circuit Transformer 11 Control Thermostat Options Digit 1 - Type of Control J**= Standard Leaving Water Control (UNT) 8**= Wired for Leaving Water Control 9**= Leaving Water Control (W7100G) C**= Wired for System 350 D**= System 350 M**= MicroTech Controller Digit 2 - Type of Reset *A*= Outside Air *R*= Return Water *Y*= None Digit 3- Always Y 12 Phase Over/Under Volt & Ground Fault Failure Protection Y= None P= Phase Under Voltage Failure Protection V= Phase Over/Under Voltage Protection ` D= Phase Over/Under Volt Failure w/led Lights G= Ground Fault Protection F= Same as P, with Ground Fault Protection H= Same as V, with Ground Fault Protection L= Same as D, with Ground Fault Protection 13 Unloader and Low Ambient Lockout Options Y= None A= High Ambient Unloader R= High Return Water Unloader B= Both A and R K= Low Ambient Lockout W= Both K and A L= Low Water Temp Cutout Z= All Above Options 14 Gauge Options Y= None A= Sizes 010-016: Suction & Discharge Pressure Gauges Sizes 020-185: Suct, Disch, and Oil Pressure Gauges 15 Replaceable Core Filter Drier Y= None R= Replaceable Core Filter Drier 16 Evaporator Selection S1= Standard Insulation, Left-Hand Connections R1= Standard Insulation, Right-Hand Connections D1= Double Insulation, Left-Hand Connections T1= Double Insulation, Right-Hand Connections 17 Protective Guard Y= Not Required A= Base Frame Guard Around Entire Unit C= Base Frame Guard Around Compressor Area Only F= Same as A, with Vertical Cond. Coil Fin Guard G= Vertical Coil Fin Guard Only Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 6

Nomenclature Unit Model Number- Complete 18 Head Pressure Control F= FanTrol L= FanTrol with Low Ambient Start S= SpeedTrol with Low Ambient Start 19 Condenser Coil Fin Material 11= Aluminum Fin / Copper Tube 21= Copper Fin / Copper Tube 31= Coated Aluminum Fin / Copper Tube 41= Coated Copper Tube / Copper Tube 20 Condenser Fan Motors 1= Open Drip-Proof (ODP) 2= Totally Enclosed (TE) 30 CRN Number (Canadian units only) Y= None 1= British Columbia 2= Alberta 3= Saskatchewan 4= Manitoba 5= Ontario 6= Quebec 7= New Brunswick 8= Nova Scotia 9= Prince Edward Island 0= Newfoundland U= Yukon 21 Indicator Package / 115V Convenience Outlet Y= None A= Cycle Counter & Hour Meter for each compressor B= Indicator Light Package C= Both A and B D= 115V Convenience Outlet F= Both C and D 23 Warranty Option A= 1-Year Parts Warranty Q= 4-Year Extended Compressor Parts Warranty 24 Approval Listing E= ETL Listed w/ ARI Certification D= C-ETL Listed w/ ARI Certification M= MEA/ETL Listed w/ ARI Certification Y= No Agency Approval 25 Packaging Options 26 MicroTech Options YYY= None Digit 1, Unit of Measure E**= English Units M**= Metric Units Digit 2, Modem *M*= Modem *Y*= No Modem Digit 3, Sensor Options **A= Water and Air Temperature Sensors **B= Refrigerant Temperature Sensor **C= Water, Air, & Refrigerant Temperature Sensors **D= % Unit Amp Draw **E= All Above Options **Y= None 28 Leaving Evaporator Fluid Temperature 44= 44 degrees F (ARI std.) 20-50= 20 through 50 degrees F Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 7

Compressors ALR 010-030D One Compressor Units Compressor # 1 Compressor Arrangements ALR 035-070D - Top View Compressor # 2 Compressor # 1 ALR 085-185D - Top View Compressor # 3 Compressor # 1 Compressor # 4 Control Box Compressor Chart Abbreviations AL = Across-the-Line Start Option PW = Part Winding Start Option Control Box Compressor # 2 Cap. Ctl. = Capacity Control # OF UL = Banks of Unloading Power Factor Correction Capacitors 20 HP Compressor 1.0 KVAR- 208/230V Units--------- 047938534 2.5 KVAR- 460V AL Units----------- 047938516 25 HP Compressor 1.0 KVAR- 208/230V Units--------- 047938534 2.0 KVAR- 460V PW Units--------- 047938515 3.0 KVAR- 460V AL Units----------- 047938517 30/35 HP Compressor 3.0 KVAR- 460V PW Units--------- 047938517 6.0 KVAR- 460V AL Units----------- 047938520 40 HP Compressor 5.0 KVAR- 208/230V Units--------- 047938505 5.0 KVAR- 460V PW Units--------- 047938519 10.0 KVAR- 460V AL Units--------- 047938523 50 HP Compressor 10.0 KVAR- 208/230V Units------- 047938509 10.0 KVAR- 460V -------------------- 047938523 60 HP Compressor 7.5 KVAR- 460V ---------------------- 047938521 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 8

Compressors Compressor Components and Accessories 035D - 185D Unloaders Complete Kit To Add to a New Replacement Compressor Kit includes: Cylinder Head, Piston Ass'y, Valve Plate, Gaskets, and Unloader Valve and Coil. -pn: 046745201 To Replace an Unloader on an Existing Compressor Kit includes: Unloader Valve, Coil and Valve Gasket. -pn: SG9980212-02 Coils 120V For 4D and 6D Compressors. -pn: 027677200 Unloader Valve Only 120V -pn: 046497300 Unloader Gasket -pn: 072927901 Crankcase Heaters 120V 100W- Used on 20-35 H.P. Compressors -pn: 059443001 120V 200W- Used on 40-60 H.P. Compressors -pn: 030178401 Motor Protectors 120V Used on all Compressors -pn: 044691500 Flange Assembly for Oil Equalization -pn: 049122701 Oil Equalization Kit -pn: 350011801 300 PSI Relief Valve All Sizes -pn: 735045850 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 9

Compressors, Continued Compressors by Unit Size ALR 010D Compressors Compressor # 1 HP= 10 Unit Steps # Of Voltage Cap.-------------------------------------------- Part Number UL Ctl. 208 1------------------------------------------------049264001 0 208 2------------------------------------------------049264002 0 230 1------------------------------------------------049264001 0 230 2------------------------------------------------049264002 0 460 1------------------------------------------------049264003 0 460 2------------------------------------------------049264004 0 380/415 1------------------------------------------------049264003 0 380/415 2------------------------------------------------049264004 0 575 1------------------------------------------------049264005 0 575 2------------------------------------------------049264006 0 ALR 013D Compressors Compressor # 1 HP= 15 Unit Steps # Of Voltage Cap.-------------------------------------------- Part Number UL Ctl. 208 1------------------------------------------------049264007 0 208 2------------------------------------------------049264008 0 230 1------------------------------------------------049264007 0 230 2------------------------------------------------049264008 0 460 1------------------------------------------------049264009 0 460 2------------------------------------------------049264010 0 380/415 1------------------------------------------------049264009 0 380/415 2------------------------------------------------049264010 0 575 1------------------------------------------------ 049264011 0 575 2------------------------------------------------049264012 0 ALR 016D Compressors Compressor # 1 HP= 20 Unit Steps # Of Voltage Cap.-------------------------------------------- Part Number UL Ctl. 208 1------------------------------------------------049264013 0 208 2------------------------------------------------049264014 0 230 1------------------------------------------------049264013 0 230 2------------------------------------------------049264014 0 460 1------------------------------------------------049264015 0 460 2------------------------------------------------049264016 0 380/415 1------------------------------------------------049264015 0 380/415 2------------------------------------------------049264016 0 575 1------------------------------------------------049264017 0 575 2------------------------------------------------049264018 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 10

Compressors, Continued Compressors by Unit Size ALR 020D Compressors Compressor # 1 HP= 25 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 2------- AL-----------066407801----------------- 1 208 2------ PW-----------066407801----------------- 1 230 2------- AL-----------066407801----------------- 1 230 2------ PW-----------066407801----------------- 1 380/460 2------- AL-----------066407801----------------- 1 380/460 2------ PW-----------066407601----------------- 1 415 2------- AL-----------066407601----------------- 1 415 2------ PW-----------066407601----------------- 1 575 2------- AL-----------066407701----------------- 1 575 2------ PW-----------066407701----------------- 1 ALR 025D Compressors Compressor # 1 HP= 30 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 2------- AL-----------066408201----------------- 1 208 2------ PW-----------066408201----------------- 1 230 2------- AL-----------066408201----------------- 1 230 2------ PW-----------066408201----------------- 1 380/460 2------- AL-----------066408201----------------- 1 380/460 2------ PW-----------066408001----------------- 1 415 2------- AL-----------066408001----------------- 1 415 2------ PW-----------066408001----------------- 1 575 2------- AL-----------066408101----------------- 1 575 2------ PW-----------066408101----------------- 1 a unloaders not included with this compressor. If unloader is required see "Compressor Components and Accessories" section. Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 11

Compressors, Continued Compressors by Unit Size ALR 030D Compressors Compressor # 1 HP= 35 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 2------- AL-----------071846701----------------- 1 208 2------ PW-----------071846701----------------- 1 230 2------- AL-----------071835401----------------- 1 230 2------ PW-----------071835401----------------- 1 380/460 2------- AL-----------071835401----------------- 1 380/460 2------ PW-----------071835501----------------- 1 415 2------- AL-----------071835501----------------- 1 415 2------ PW-----------071835501----------------- 1 575 2------- AL-----------071835601----------------- 1 575 2------ PW-----------071835601----------------- 1 208 3------- AL-----------071846801-----------------2 a 208 3------ PW-----------071846801-----------------2 a 230 3------- AL-----------071835401-----------------2 a 230 3------ PW-----------071835401-----------------2 a 380/460 3------- AL-----------071835401-----------------2 a 380/460 3------ PW-----------071836901-----------------2 a 415 3------- AL-----------071836901-----------------2 a 415 3------ PW-----------071836901-----------------2 a 575 3------- AL-----------071837001-----------------2 a 575 3------ PW-----------071837001-----------------2 a a unloaders not included with this compressor. If unloader is required see "Compressor Components and Accessories" section. Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 12

Compressors, Continued Compressors by Unit Size ALR 035D Compressors Compressor # 1 HP= 22 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------071835101----------------- 1 208 4------ PW-----------071835101----------------- 1 230 4------- AL-----------071835101----------------- 1 230 4------ PW-----------071835101----------------- 1 380/460 4------- AL-----------071835101----------------- 1 380/460 4------ PW-----------071835201----------------- 1 415 4------- AL-----------071835201----------------- 1 415 4------ PW-----------071835201----------------- 1 575 4------- AL-----------071835301----------------- 1 575 4------ PW-----------071835301----------------- 1 Compressor # 2 HP= 22 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------071835101----------------- 1 208 4------ PW-----------071835101----------------- 1 230 4------- AL-----------071835101----------------- 1 230 4------ PW-----------071835101----------------- 1 380/460 4------- AL-----------071835101----------------- 1 380/460 4------ PW-----------071835201----------------- 1 415 4------- AL-----------071835201----------------- 1 415 4------ PW-----------071835201----------------- 1 575 4------- AL-----------071835301----------------- 1 575 4------ PW-----------071835301----------------- 1 ALR 040D Compressors Compressor # 1 HP= 25 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------066407801----------------- 1 208 4------ PW-----------066407801----------------- 1 230 4------- AL-----------066407801----------------- 1 230 4------ PW-----------066407801----------------- 1 380/460 4------- AL-----------066407801----------------- 1 380/460 4------ PW-----------066407601----------------- 1 415 4------- AL-----------066407601----------------- 1 415 4------ PW-----------066407601----------------- 1 575 4------- AL-----------066407701----------------- 1 575 4------ PW-----------066407701----------------- 1 Compressor # 2 HP= 30 Unit Steps Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------066408201----------------- 1 208 4------ PW-----------066408201----------------- 1 230 4------- AL-----------066408201----------------- 1 230 4------ PW-----------066408201----------------- 1 380/460 4------- AL-----------066408201----------------- 1 380/460 4------ PW-----------066408001----------------- 1 415 4------- AL-----------066408001----------------- 1 415 4------ PW-----------066408001----------------- 1 575 4------- AL-----------066408101----------------- 1 575 4------ PW-----------066408101----------------- 1 ALR 050D Compressors Compressor # 1 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------071846201----------------- 1 208 4------ PW-----------071846201----------------- 1 230 4------- AL-----------071846201----------------- 1 230 4------ PW-----------071846201----------------- 1 380/460 4------- AL-----------071846201----------------- 1 380/460 4------ PW-----------071846101----------------- 1 415 4------- AL-----------071846101----------------- 1 415 4------ PW-----------071846101----------------- 1 575 4------- AL-----------071846601----------------- 1 575 4------ PW-----------071846601----------------- 1 Compressor # 2 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 4------- AL-----------071846201----------------- 1 208 4------ PW-----------071846201----------------- 1 230 4------- AL-----------071846201----------------- 1 230 4------ PW-----------071846201----------------- 1 380/460 4------- AL-----------071846201----------------- 1 380/460 4------ PW-----------071846101----------------- 1 415 4------- AL-----------071846101----------------- 1 415 4------ PW-----------071846101----------------- 1 575 4------- AL-----------071846601----------------- 1 575 4------ PW-----------071846601----------------- 1 a unloaders not included with this compressor. If unloader is required see "Compressor Components and Accessories" section. Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 13

Compressors, Continued Compressors by Unit Size, Continued ALR 060D Compressors Compressor # 1 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 4------- AL-----------071846201----------------- 1 208 4------ PW-----------071846201----------------- 1 230 4------- AL-----------071846201----------------- 1 230 4------ PW-----------071846201----------------- 1 380/460 4------- AL-----------071846201----------------- 1 380/460 4------ PW-----------071846101----------------- 1 415 4------- AL-----------071846101----------------- 1 415 4------ PW-----------071846101----------------- 1 575 4------- AL-----------071846601----------------- 1 575 4------ PW-----------071846601----------------- 1 208 6------- AL-----------071838301-----------------2 a 208 6------ PW-----------071838301-----------------2 a 230 6------- AL-----------071838301-----------------2 a 230 6------ PW-----------071838301-----------------2 a 380/460 6------- AL-----------071838301-----------------2 a 380/460 6------ PW-----------071838401-----------------2 a 415 6------- AL-----------071838401-----------------2 a 415 6------ PW-----------071838401-----------------2 a 575 6------- AL-----------071838501-----------------2 a 575 6------ PW-----------071838501-----------------2 a ALR 070D Compressors Compressor # 1 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 4------- AL-----------071835901----------------- 1 208 4------ PW-----------071835901----------------- 1 230 4------- AL-----------071835701----------------- 1 230 4------ PW-----------071835701----------------- 1 380/460 4------- AL-----------071835701----------------- 1 380/460 4------ PW-----------071835801----------------- 1 415 4------- AL-----------071835801----------------- 1 415 4------- AL-----------071835801----------------- 1 575 4------- AL-----------071837801----------------- 1 575 4------ PW-----------071837801----------------- 1 208 6------- AL-----------071838001-----------------2 a 208 6------ PW-----------071838001-----------------2 a 230 6------- AL-----------071837601-----------------2 a 230 6------ PW-----------071837601-----------------2 a 380/460 6------- AL-----------071837601-----------------2 a 380/460 6------ PW-----------071837701-----------------2 a 415 6------- AL-----------071837701-----------------2 a 415 6------ PW-----------071837701-----------------2 a 575 6------- AL-----------071837801-----------------2 a 575 6------ PW-----------071837801-----------------2 a Compressor # 2 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 4------- AL-----------071846701----------------- 1 208 4------ PW-----------071846701----------------- 1 230 4------- AL-----------071835401----------------- 1 230 4------ PW-----------071835401----------------- 1 380/460 4------- AL-----------071835401----------------- 1 380/460 4------ PW-----------071835501----------------- 1 415 4------- AL-----------071835501----------------- 1 415 4------ PW-----------071835501----------------- 1 575 4------- AL-----------071835601----------------- 1 575 4------ PW-----------071835601----------------- 1 208 6------- AL-----------071846801-----------------2 a 208 6------ PW-----------071846801-----------------2 a 230 6------- AL-----------071835401-----------------2 a 230 6------ PW-----------071835401-----------------2 a 380/460 6------- AL-----------071835401-----------------2 a 380/460 6------ PW-----------071836901-----------------2 a 415 6------- AL-----------071836901-----------------2 a 415 6------ PW-----------071836901-----------------2 a 575 6------- AL-----------071837001-----------------2 a 575 6------ PW-----------071837001-----------------2 a Compressor # 2 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 4------- AL-----------071835901----------------- 1 208 4------ PW-----------071835901----------------- 1 230 4------- AL-----------071835701----------------- 1 230 4------ PW-----------071835701----------------- 1 380/460 4------- AL-----------071835701----------------- 1 380/460 4------ PW-----------071835801----------------- 1 415 4------- AL-----------071835801----------------- 1 415 4------- AL-----------071835801----------------- 1 575 4------- AL-----------071837801----------------- 1 575 4------ PW-----------071837801----------------- 1 208 6------- AL-----------071838001-----------------2 a 208 6------ PW-----------071838001-----------------2 a 230 6------- AL-----------071837601-----------------2 a 230 6------ PW-----------071837601-----------------2 a 380/460 6------- AL-----------071837601-----------------2 a 380/460 6------ PW-----------071837701-----------------2 a 415 6------- AL-----------071837701-----------------2 a 415 6------ PW-----------071837701-----------------2 a 575 6------- AL-----------071837801-----------------2 a 575 6------ PW-----------071837801-----------------2 a a unloaders not included with this compressor. If unloader is required see "Compressor Components and Accessories" section. Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 14

Compressors, Continued Compressors by Unit Size, Continued ALR 085D Compressors Compressor # 1 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------066408201----------------- 1 208 6/8----- PW-----------066408201----------------- 1 230 6/8------ AL-----------066408201----------------- 1 230 6/8----- PW-----------066408201----------------- 1 380/460 6/8------ AL-----------066408201----------------- 1 380/460 6/8----- PW-----------066408001----------------- 1 415 6/8------ AL-----------066408001----------------- 1 415 6/8----- PW-----------066408001----------------- 1 575 6/8------ AL-----------066408101----------------- 1 575 6/8----- PW-----------066408101----------------- 1 Compressor # 2 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------066408201----------------- 1 208 6/8----- PW-----------066408201----------------- 1 230 6/8------ AL-----------066408201----------------- 1 230 6/8----- PW-----------066408201----------------- 1 380/460 6/8------ AL-----------066408201----------------- 1 380/460 6/8----- PW-----------066408001----------------- 1 415 6/8------ AL-----------066408001----------------- 1 415 6/8----- PW-----------066408001----------------- 1 575 6/8------ AL-----------066408101----------------- 1 575 6/8----- PW-----------066408101----------------- 1 Compressor # 3 HP= 25 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------066407501----------------- 0 208 6/8----- PW-----------066407501----------------- 0 230 6/8------ AL-----------066407501----------------- 0 230 6/8----- PW-----------066407501----------------- 0 380/460 6/8------ AL-----------066407501----------------- 0 380/460 6/8----- PW-----------066407401----------------- 0 415 6/8------ AL-----------066407401----------------- 0 415 6/8----- PW-----------066407401----------------- 0 575 6/8------ AL-----------066407701----------------- 0 575 6/8----- PW-----------066407701----------------- 0 Compressor # 4 HP= 25 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number-------------- UL Ctl. 208 6/8------ AL-----------066407501----------------- 0 208 6/8----- PW-----------066407501----------------- 0 230 6/8------ AL-----------066407501----------------- 0 230 6/8----- PW-----------066407501----------------- 0 380/460 6/8------ AL-----------066407501----------------- 0 380/460 6/8----- PW-----------066407401----------------- 0 415 6/8------ AL-----------066407401----------------- 0 415 6/8----- PW-----------066407401----------------- 0 575 6/8------ AL-----------066407701----------------- 0 575 6/8----- PW-----------066407701----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 15

Compressors, Continued Compressors by Unit Size, Continued ALR 100D Compressors Compressor # 1 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 2 HP= 35 Unit Steps-- Start # OF Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 3 HP= 25 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------066407501----------------- 0 208 6/8----- PW-----------066407501----------------- 0 230 6/8------ AL-----------066407501----------------- 0 230 6/8----- PW-----------066407501----------------- 0 380/460 6/8------ AL-----------066407501----------------- 0 380/460 6/8----- PW-----------066407401----------------- 0 415 6/8------ AL-----------066407401----------------- 0 415 6/8----- PW-----------066407401----------------- 0 575 6/8------ AL-----------066407701----------------- 0 575 6/8----- PW-----------066407701----------------- 0 Compressor # 4 HP= 25 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------066407501----------------- 0 208 6/8----- PW-----------066407501----------------- 0 230 6/8------ AL-----------066407501----------------- 0 230 6/8----- PW-----------066407501----------------- 0 380/460 6/8------ AL-----------066407501----------------- 0 380/460 6/8----- PW-----------066407401----------------- 0 415 6/8------ AL-----------066407401----------------- 0 415 6/8----- PW-----------066407401----------------- 0 575 6/8------ AL-----------066407701----------------- 0 575 6/8----- PW-----------066407701----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 16

Compressors, Continued Compressors by Unit Size, Continued ALR 110D Compressors Compressor # 1 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 6/8------ AL-----------071846201----------------- 1 208 6/8----- PW-----------071846201----------------- 1 230 6/8------ AL-----------071846201----------------- 1 230 6/8----- PW-----------071846201----------------- 1 380/460 6/8------ AL-----------071846201----------------- 1 380/460 6/8----- PW-----------071846101----------------- 1 415 6/8------ AL-----------071846101----------------- 1 415 6/8----- PW-----------071846101----------------- 1 575 6/8------ AL-----------071846601----------------- 1 575 6/8----- PW-----------071846601----------------- 1 Compressor # 2 HP= 30 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number---------------UL a Ctl. 208 6/8------ AL-----------071846201----------------- 1 208 6/8----- PW-----------071846201----------------- 1 230 6/8------ AL-----------071846201----------------- 1 230 6/8----- PW-----------071846201----------------- 1 380/460 6/8------ AL-----------071846201----------------- 1 380/460 6/8----- PW-----------071846101----------------- 1 415 6/8------ AL-----------071846101----------------- 1 415 6/8----- PW-----------071846101----------------- 1 575 6/8------ AL-----------071846601----------------- 1 575 6/8----- PW-----------071846601----------------- 1 Compressor # 3 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850301----------------- 0 208 6/8----- PW-----------071850301----------------- 0 230 6/8------ AL-----------071837101----------------- 0 230 6/8----- PW-----------071837101----------------- 0 380/460 6/8------ AL-----------071837101----------------- 0 380/460 6/8----- PW-----------071837201----------------- 0 415 6/8------ AL-----------071837201----------------- 0 415 6/8----- PW-----------071837201----------------- 0 575 6/8------ AL-----------071835601----------------- 0 575 6/8----- PW-----------071835601----------------- 0 Compressor # 4 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850301----------------- 0 208 6/8----- PW-----------071850301----------------- 0 230 6/8------ AL-----------071837101----------------- 0 230 6/8----- PW-----------071837101----------------- 0 380/460 6/8------ AL-----------071837101----------------- 0 380/460 6/8----- PW-----------071837201----------------- 0 415 6/8------ AL-----------071837201----------------- 0 415 6/8----- PW-----------071837201----------------- 0 575 6/8------ AL-----------071835601----------------- 0 575 6/8----- PW-----------071835601----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 17

Compressors, Continued Compressors by Unit Size, Continued ALR 120D Compressors Compressor # 1 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 2 HP= 35 Unit Steps-- Start # OF Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 3 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850301----------------- 0 208 6/8----- PW-----------071850301----------------- 0 230 6/8------ AL-----------071837101----------------- 0 230 6/8----- PW-----------071837101----------------- 0 380/460 6/8------ AL-----------071837101----------------- 0 380/460 6/8----- PW-----------071837201----------------- 0 415 6/8------ AL-----------071837201----------------- 0 415 6/8----- PW-----------071837201----------------- 0 575 6/8------ AL-----------071835601----------------- 0 575 6/8----- PW-----------071835601----------------- 0 Compressor # 4 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850301----------------- 0 208 6/8----- PW-----------071850301----------------- 0 230 6/8------ AL-----------071837101----------------- 0 230 6/8----- PW-----------071837101----------------- 0 380/460 6/8------ AL-----------071837101----------------- 0 380/460 6/8----- PW-----------071837201----------------- 0 415 6/8------ AL-----------071837201----------------- 0 415 6/8----- PW-----------071837201----------------- 0 575 6/8------ AL-----------071835601----------------- 0 575 6/8----- PW-----------071835601----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 18

Compressors, Continued Compressors by Unit Size, Continued ALR 130D Compressors Compressor # 1 HP= 35 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 2 HP= 35 Unit Steps-- Start # OF Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071846701----------------- 1 208 6/8----- PW-----------071846701----------------- 1 230 6/8------ AL-----------071835401----------------- 1 230 6/8----- PW-----------071835401----------------- 1 380/460 6/8------ AL-----------071835401----------------- 1 380/460 6/8----- PW-----------071835501----------------- 1 415 6/8------ AL-----------071835501----------------- 1 415 6/8----- PW-----------071835501----------------- 1 575 6/8------ AL-----------071835601----------------- 1 575 6/8----- PW-----------071835601----------------- 1 Compressor # 3 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850401----------------- 0 208 6/8----- PW-----------071850401----------------- 0 230 6/8------ AL-----------071837501----------------- 0 230 6/8----- PW-----------071837501----------------- 0 380/460 6/8------ AL-----------071837501----------------- 0 380/460 6/8----- PW-----------071837901----------------- 0 415 6/8------ AL-----------071837901----------------- 0 415 6/8----- PW-----------071837901----------------- 0 575 6/8------ AL-----------071837801----------------- 0 575 6/8----- PW-----------071837801----------------- 0 Compressor # 4 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850401----------------- 0 208 6/8----- PW-----------071850401----------------- 0 230 6/8------ AL-----------071837501----------------- 0 230 6/8----- PW-----------071837501----------------- 0 380/460 6/8------ AL-----------071837501----------------- 0 380/460 6/8----- PW-----------071837901----------------- 0 415 6/8------ AL-----------071837901----------------- 0 415 6/8----- PW-----------071837901----------------- 0 575 6/8------ AL-----------071837801----------------- 0 575 6/8----- PW-----------071837801----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 19

Compressors, Continued Compressors by Unit Size, Continued ALR 135D Compressors Compressor # 1 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071835901----------------- 1 208 6/8----- PW-----------071835901----------------- 1 230 6/8------ AL-----------071835701----------------- 1 230 6/8----- PW-----------071835701----------------- 1 380/460 6/8------ AL-----------071835701----------------- 1 380/460 6/8----- PW-----------071835801----------------- 1 415 6/8------ AL-----------071835801----------------- 1 415 6/8----- PW-----------071835801----------------- 1 575 6/8------ AL-----------071837801----------------- 1 575 6/8----- PW-----------071837801----------------- 1 Compressor # 2 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071835901----------------- 1 208 6/8----- PW-----------071835901----------------- 1 230 6/8------ AL-----------071835701----------------- 1 230 6/8----- PW-----------071835701----------------- 1 380/460 6/8------ AL-----------071835701----------------- 1 380/460 6/8----- PW-----------071835801----------------- 1 415 6/8------ AL-----------071835801----------------- 1 415 6/8----- PW-----------071835801----------------- 1 575 6/8------ AL-----------071837801----------------- 1 575 6/8----- PW-----------071837801----------------- 1 Compressor # 3 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850401----------------- 0 208 6/8----- PW-----------071850401----------------- 0 230 6/8------ AL-----------071837501----------------- 0 230 6/8----- PW-----------071837501----------------- 0 380/460 6/8------ AL-----------071837501----------------- 0 380/460 6/8----- PW-----------071837901----------------- 0 415 6/8------ AL-----------071837901----------------- 0 415 6/8----- PW-----------071837901----------------- 0 575 6/8------ AL-----------071837801----------------- 0 575 6/8----- PW-----------071837801----------------- 0 Compressor # 4 HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071850401----------------- 0 208 6/8----- PW-----------071850401----------------- 0 230 6/8------ AL-----------071837501----------------- 0 230 6/8----- PW-----------071837501----------------- 0 380/460 6/8------ AL-----------071837501----------------- 0 380/460 6/8----- PW-----------071837901----------------- 0 415 6/8------ AL-----------071837901----------------- 0 415 6/8----- PW-----------071837901----------------- 0 575 6/8------ AL-----------071837801----------------- 0 575 6/8----- PW-----------071837801----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 20

Compressors, Continued Compressors by Unit Size, Continued ALR 145D Compressors Compressor # 1: With or Without Oil Equalization HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071835901----------------- 1 208 6/8----- PW-----------071835901----------------- 1 230 6/8------ AL-----------071835701----------------- 1 230 6/8----- PW-----------071835701----------------- 1 380/460 6/8------ AL-----------071835701----------------- 1 380/460 6/8----- PW-----------071835801----------------- 1 415 6/8------ AL-----------071835801----------------- 1 415 6/8----- PW-----------071835801----------------- 1 575 6/8------ AL-----------071837801----------------- 1 575 6/8----- PW-----------071837801----------------- 1 Compressor # 2: With or Without Oil Equalization HP= 40 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071835901----------------- 1 208 6/8----- PW-----------071835901----------------- 1 230 6/8------ AL-----------071835701----------------- 1 230 6/8----- PW-----------071835701----------------- 1 380/460 6/8------ AL-----------071835701----------------- 1 380/460 6/8----- PW-----------071835801----------------- 1 415 6/8------ AL-----------071835801----------------- 1 415 6/8----- PW-----------071835801----------------- 1 575 6/8------ AL-----------071837801----------------- 1 575 6/8----- PW-----------071837801----------------- 1 Compressor # 3: Without Oil Equalization HP= 50 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------047137100----------------- 0 208 6/8----- PW-----------047137100----------------- 0 230 6/8------ AL-----------047137100----------------- 0 230 6/8----- PW-----------047137100----------------- 0 380/460 6/8------ AL-----------047137200----------------- 0 380/460 6/8----- PW-----------047137200----------------- 0 415 6/8------ AL-----------047137200----------------- 0 415 6/8----- PW-----------047137200----------------- 0 575 6/8------ AL-----------047137300----------------- 0 575 6/8----- PW-----------047137300----------------- 0 Compressor # 4: Without Oil Equalization HP= 50 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------047137100----------------- 0 208 6/8----- PW-----------047137100----------------- 0 230 6/8------ AL-----------047137100----------------- 0 230 6/8----- PW-----------047137100----------------- 0 380/460 6/8------ AL-----------047137200----------------- 0 380/460 6/8----- PW-----------047137200----------------- 0 415 6/8------ AL-----------047137200----------------- 0 415 6/8----- PW-----------047137200----------------- 0 575 6/8------ AL-----------047137300----------------- 0 575 6/8----- PW-----------047137300----------------- 0 Compressor # 3: With Oil Equalization HP= 50 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071667801----------------- 0 208 6/8----- PW-----------071667801----------------- 0 230 6/8------ AL-----------071667801----------------- 0 230 6/8----- PW-----------071667801----------------- 0 380/460 6/8------ AL-----------071667901----------------- 0 380/460 6/8----- PW-----------071667901----------------- 0 415 6/8------ AL-----------071667901----------------- 0 415 6/8----- PW-----------071667901----------------- 0 575 6/8------ AL-----------047137300----------------- 0 575 6/8----- PW-----------047137300----------------- 0 Compressor # 4: With Oil Equalization HP= 50 Unit Steps-- Start # Of Voltage Cap.-- Option------ Part Number--------------- UL Ctl. 208 6/8------ AL-----------071667801----------------- 0 208 6/8----- PW-----------071667801----------------- 0 230 6/8------ AL-----------071667801----------------- 0 230 6/8----- PW-----------071667801----------------- 0 380/460 6/8------ AL-----------071667901----------------- 0 380/460 6/8----- PW-----------071667901----------------- 0 415 6/8------ AL-----------071667901----------------- 0 415 6/8----- PW-----------071667901----------------- 0 575 6/8------ AL-----------047137300----------------- 0 575 6/8----- PW-----------047137300----------------- 0 Reciprocating Chiller; ALR 010-185 "D" Rev. S 07/15 RPL 571152 /Page 21