SECTIONAL - 750(1200) INSTALLATION MANUAL

Similar documents
R3 Roller Garage Door Opener

Instruction Manual MB4 Rolling garage door opener

GARAGE DOOR OPERATOR USER S MANUAL

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

D-FORCE1500PV GARAGE DOOR OPENER

PY600AC Sliding Gate Opener User Manual

contents Maintenance Operator Installation and Operating Manual DoorHan, 2012

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

Sectional and Tilting Door Opener

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Sectional and Tilting Door Opener Installation Instructions and User Guide

AUTOMATIC CONTROL ROLLING DOOR OPENER

Sectional and Tilting Door Opener Installation Instructions and User Guide

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Sliding Gate Operator User's Manual

WWWAUTO-ROLLER.CO.ZA INSTALLATION MANUAL AUTO- ROLLER

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

OPERATOR SECTIONAL-500//DIY-500. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SWING GATE OPENER SW300 SERIES

Roller Door Operator

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

GCU-10. Automatic Engine Control Unit Operators Manual

ROSSO EVO User s and Installer s manual

Types of Doors that can be automated using the digi.one: Sectional overhead doors, single/double, steel or timber. Tip up doors, steel or timber.

IMPORTANT SAFETY RECOMMENDATIONS

SKC-500DC SLIDING GATE OPENER OWNER S MANUAL

Instruction Manual LA-SDO1 Sectional garage door opener

Sliding Gate Operator User's Manual

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

KVM 25 OPERATION MANUAL / INSTALLER

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

F350/F360 doc. F05 doc. F05P1. F350 Classic. F360 Duro. Specifications. iss V1.1

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

Acdc slimglide roller door operator

Rolling Door Operator User s Manual

Sectional And Tilting Door Opener

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Gate & Door Controller with LCD and Intelligent Technology

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

TEL: G&C Electronics CC E. T.

ROSSO EVO USER'S AND INSTALLER'S MANUAL. v2.3 REV. 01/2015

12V Central Lock Universal Remote For Keyless Entry p/n

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

VEHICLE CONTROLS Walk Away Auto Lock*

contents Installation Maintenance DOOR OPERATOR SLIDING-1300/2100 Installation and Operating Manual DoorHan, 2012

Index. 4. DESCRIPTION... p PRELIMINARY CHECKS... p ASSEMBLY... p. 6

Bio Lion Table Top Centrifuge XC-L5

YG101 SWING GATE OPENER OWNER S MANUAL

DTS 600/800 SECTIONAL DOOR OPERATOR INSTALLATION MANUAL. Comply to: SANS IEC NRCS Cert. no /002

TALFM-TW INSTALLATION INSTRUCTIONS

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Using the Key or Remote Transmitter*

GARAGE DOOR OPENER MODEL: HANDLES DOORS 18 FT. WIDE & UP TO 7FT.TALL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

Roll Up Door Operator

Model APS-20B Owner's Manual

COOKSON OWNER'S MANUAL

DL8FM-TW INSTALLATION INSTRUCTIONS

Model PRO-9675FT4 Owner's Manual

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

INSTALLATION MANUAL ROAD GATE BARRIER BARRIER-5000

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

Rolling Door Opener INSTALLATION INSTRUCTION AND OWNERS MANUAL

Uninterruptible Power System

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

Warranty Registration

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

VER KIT. Installation Instructions TECHNICAL HELPLINE

UMPETHA U / Domestic sliding gate operator by ET SYSTEMS. USER GUIDE

Uninterruptible Power System

IMPORTANT SAFETY RECOMMENDATIONS


AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

USER GUIDE KAS-840-DEN KAS-850-RDEN

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS SLIDING SHUTTER MOTOR

30A ESC Manual. Specification: Burst

The monitor can be placed on the dashboard, on the sun visor or mounted in any convenient place in the vehicle.

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

For more information: or call toll free at

INSTALLATION GUIDE Table of Contents

Letron Auto Gates (Australia) Pty. Ltd. User s Installation Manual

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

DL300 FINGERPRINT LOCK

DTS SLIDING GATE MOTOR INSTALLATION MANUAL. DTS 600 Elite with SL150 PCB DTS SECURITY P.O.BOX 3399 EDENVALE 1610 TELEPHONE

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

CRUISE CONTROL SYSTEM

Signet Pressure Transmitter

RS900 / RS901 SERIES V

DESCRIPTION & OPERATION

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

Transcription:

SECTIONAL 750(1200) INSTALLATION MANUAL

Contents A. Inventory...3 B. Function Introduction...4 C. Assembly rocedure...5 D. The Main Body and rogram anel...9 E. Wiring Diagram for Infraed Beam...10 F. rogramming...11 G. rogramming of Transmitters...18 H. Technical Specifications...19 I. End User s Guide...20 J. Assembly of the ail in 2 arts...22 K. Annex. Wiring Drawing...24 2

Opener ack Opener (1x) Manual (1x) Wireless Wall Control (1x) Curved Door Arm (1x) Mounting Strap (1x) Support Bracket (1x) U Bracket (3x) Header Door Bracket (1x) 6x15 Hexagon Head Bracket (1x) Driving Screw (8x) lum Offset ing (1x) 8x25 Inserted in (1x) 3x20 Cotter in (1x) 6x8 Screw with Hexagon Nut (1x) 6x80 Expanding Screw (6x) 8x20 Screw with Hexagon Nut (4x) reassembled ail 3

B Function Introduction Intelligent Computerized Control Intelligent computerized precise travel positioning; timely force detection, reversion occurs when obstacles are met. Motor Smooth noise, smooth start, slow stop protect the motor and ensure a long service time. Self Diagnosis Operational Mode and digital menu are displayed on the control Cryptoguard olling code technoloy provides billions of code combinations and makes every remote control a unique one that protects against unauthorized access Alarm Device The alarm will sound if the door is left opened for over 10 minutes. The alarm stops when the door is closed again. (efer to f7 on.14) Emergency elease The door can be manually operated by pulling down the emergency release rope in case of power failure. (efer to C4 on.8) Additional Safety Device Safety further ensured with additional accessory photocells. (efer to E on.10) Automatic closing door The automatic closing time of the door can be set from 30 seconds to 240 seconds. (efer to F8 on.14) 2000 cycles alarm When the operator has run 2000 cycles, it will beep to remind the user to maintain the mechanical system. (efer to F9 on.16) Essential Tools 4

C2 Connecting The Body With The ail The special one with a micro switch should be mounted referring to the figure below 1. 6x15Driving screw 2. U Type bracket 3. ail 4. Spline bushing 1. 6x15 driving screw 2. U Type bracket 3. ail 4. Spline bushing 5. Micro switch 5 5

C3 How To Fix The Body And The ail Wall Door Header Bracket ail 6x80 screw Expand screw Door Bracket 6x15 driving screw Curved Door Arm 8x25 inserted pin Flat iron 8x20 screw U Type Bracket Çà äîïîëíèòåëüíîé èíôîðìàöèåé îáðàùàéòåñü ê ìåíåäæåðàì ãðóïïû êîìïàíèé DoorHan. Òåë.: 7(495)9811221, 88002009899 / www.doorhan.ru / rmail: support@doorhan.ru 121354, Ìîñêâà, Ìîæàéñêîå øîññå, 36 / òåë.: 7(495)9332400 / ôàêñ: 7(495)9379550 6

C4. How To Open The Door Manually In the case of power failure ail ope Clutch (1). When the door is in closed position: ull down on the rope and disengage the clutch, this will allow the door to be lifted with easily. (2). When the door is in the open position: ull down on the rope once, this will allow the door to move downward to the closed position. If power recovers (NB: If the rail is 1section type, the system features the selflock function but 2sections does not.) Operate the handheld transmitter or the wall control again, the clutch will be reengaged automatically. 7

D. The Main Body and rogram anel Key for code Key for adjustment Key for function Indicator for code setting and signal receiving Indicator for work procedure and working state Key for adjustment Emitting indicator Light controlling knob Door controlling knob Light for the garage 8

K. Annex: Wiring drawing Character Components Distance Voltage Current 12ì 12/24 150ìÀ The connector for wired control (DoorHan) Gnd 24 12/24 Nc Com VD No Kn1 Com Nc No Gnd 24 NC NO Com Out Cn4 eceiver 5 U I Main panel DH350G Cn5 CU TANSIN TANSOUT F1 2,5À F2 10À ACL/IN ACN/IN LAM The connector for lamp 220V ower Connector The connector for the motor 9

F. rogramming repare A. Gently move the door to engage the trolley so that the opener can drive the door B. Turn the power on, the light will come on, the unit will beep once and the display shows 0 in cycles. If the final programming is not carried out, the settings will be deleted automatically. If a wrong information has been programmed, you can turn the power off and then turn it on again to reset, referring to the following. Upper Limit Setting ress key p (about 5 seconds) The unit beeps once and shows 1 ress p, 1 flashes ress Or press Door goes up When the door rises to an ideal position, press key to save the Information Down Limit Setting ress to show 2 ress p, 2 flashes ress Or press Door goes down When the door descends toan ideal position, after 2 seconds press key to save the information 10

rogramming Operating Force Learning ress, shows 3 ress p, 3 flashes Door rises automatically ress p after stops, press p again After the above basic settings, the user can now carry out the finalizing step to finalize the programming S Force Level Setting The unit has been preset on the factory at level 4,resetting by end users is not required. ress to show 4 S ress p ress 3 sec Low Force level Door descends Set in the factory press or for changing force level Manual adjustment (max force level 60 kg) ress to save the information, refer to High If the force level is set too low, the door moving will be affected when the mechanical structure of the door is not wellbalanced 3 sec press or for changing force level Automatic adjustment (max force level 20 kg) ress to p to save the settings Transmitter Control Button Settings ress to show 5 ress p, 2 flashes, it ress or,to choose means now the door a desired button from 1 to 4 control channel is set at the second button of the transmitter Set in the factory The motor has been set at channel 2 at the factory to control the door, 0 means no channel is chosen 11

rogramming Alarm Settings If the not closed in 10 minutes, system turns on alarm sound. ress, shows 6 ress p, it shows 0, it means the alarm settings are off ress, it shows 1, it means the alarm setting are on Automatic Closing Time Settings ress, shows 7 ress to show 0, it means the function is off ress to show 1 to turn the function on, it also means the auto closing time is 30 seconds 9 2000 Cycles Alarm Setting ress, shows 8 ress p, it shows 0, it means the function is off ress,it shows 1, it means this function is on 12

rogramming of Transmitters 6.10 Final rogramming. (NB: This finalizing step must be carried out, otherwise the saved information will be lost) rogramming of Transmitters Decode ress & hold for 8 seconds 0 will be shown on the left side of the display. Keep pressing the key until 0 disappeares By now, no transmitters can operate the opener unless recoded. For security purpose if a transmitter has been lost the opener must be decoded and the new transmitter encoded as above, so that the lost one can not operate the door anymore. ress S 0 will be shown on the left side of the display, and disappears immediately ress any key twice, coding is completed. At this time, the code isuccessfully set if opener works. Other transmitters can be set as above. 13

H. Technical Specification H1 Model and ecommended Usage Model Voltage(V) Area of the door(m) SE750 SE1200 10 H2 Guide ail and Available Sizes 16 Model Total length Travel of the rail Surrounding difference in temperature(c) Height of the door in rising H3 Specification List ower Standby mode ulling force Controller Controlling method Motor Light W SE750, W SE1200 4W when the motor and the light are off 700N/ SE750,1100N/ SE1200 CU Impulse inducting 24V.DC. 25W (1x);E14 Speed of the door 11cm/second Fuse Model ower Fuse 1: 2.5A; Light Fuse 2: 2.5A Speed Induction hoto electric induction Transmitter frequency and distance 433 Mhz/ open space 50m Drive Chain rotecting Method Keep in dry room (I 20) 14

I. End User s Guide I1 Care Of The Opener A. SE750 type opener is an environmentally friendly product generally requiring a minimum of maintenance in normal use. B. For the first operation, please examine the drive system to see whether it moves easily (elease the clutch, push and pull the door manually) C. After a period of time in use, regularly check whether the door is balanced when opening/closing, whether the spring has enough force to raise the door. D. In the case of power failure the operator can search for the program memory. When the power is restored, press the button of the transmitter once, the door will rise. The door stops moving in the case of power failure I2 Normal Operation When the power is restored, press the transmitter, the door moves up According to the program memory, the door will rise to the upper limit position and then stop A. emote Control Opening, closing or stopping can be achieved by pushing of a single button on the transmitter B. Manual operation In case of power failure, opening or closing of the door can be done by hand once the clutch is released (lease refer to.8) I3 Trouble Shooting Fault Causes Deal With The opener does 1. The plug is not securely fitted 1. Check by a technician not work 2.The fuse is blown 2.eplace the same type of fuse by a technician The door does not work 1. No code has been set 2. The battery is out of power 1. ecode referring to G1on.18 2. eplace a new battery emote control The battery is eplace with a new one distance is too short not powerful enough of the same model The chain moves, The clutch may be Lock the clutch referring but the door does not unlocked to C4 on.8 The alarm keeps 1. Door is opened too long 1. Close the door beeping 2. 2000 cycles alarm 2. Turn the power off, then recover again The door is not at the position when opened Failure in setup Set again referring to F on.11 or closed, or not working The door does not work in normal, and H is shown on the screen Sudden stop or bounce while working, and F is shown on the screen While working, a grating sound can be heard The chain has come loose and is noisy Computer failure due to humidity 1. The torque spring is distorted 2.Obstacle is met 3. The power is not stable Lack of lubricant between the rail and the clutch after a long period of use Chain was used for a long time without lubricant between the rail and the clutch Dry out the unit (by a technician) 1.Adjust the torque spring 2. emove obstacle 2.Adjust the resistance to a proper level unit F disappears Add suitable amount of lubricant or wax to the position between the rail and the clutch Fasten the bolt on the spring, holding the chain stable and lubricate it (efer to 4 on 23) To avoid being electrocuted, only a professional technician is allowed to touch the wires and components on the main panel. 15

143002 ussia, Moscow egion Odintsovo City, Mozhayskoe Chosse Km. 27 Tel: 7(495)933 2400, 981 1133 Fax: 7(495)937 9550 E mail: Info@doorhan.ru