L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Similar documents
L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L312 LIQUID LEVEL FLOAT SWITCH. Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

L500 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

LIQUID LEVEL FLOAT SWITCH. F7 Series INSTALLATION AND OPERATIONS MANUAL. Single-Point, Vertically-Mounted Liquid Level Float Switch

For Hazardous Locations

L070 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL. For Industrial Use

For CRN Installations

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Tuffy Liquid Level Controls with Pneumatic Switch

Installation and Operating Manual

Series K Pneumatic Switch Mechanism

J52 Refrigerant Level Switches

Tuffy II Liquid Level Controls with Electric Switches Installation and Operating Manual

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

M-100 Adjustable flow switch with right-angle flow

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Tuffy Liquid Level Switches

KOBOLD SV FLOWMETER/SWITCH. User Instructions

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

Model B73 & Series 75

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Displacer Type. Installation and Operating Manual. Liquid Level and Proof-er Switches

TITAN FLOW CONTROL, INC.

McCANNA Actuation Systems B

NCP/NCB/NCS. Magnetic Float Switches. for Liquids

Installation, Operation, and Maintenance Manual

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

Series K. Pneumatic. switch mechanism. and housings. Installation and Operating Manual

COOKSON OWNER'S MANUAL

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

TITAN FLOW CONTROL, INC.

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

HALLMARK INDUSTRIES INC

PVI 60KW, PVI 82KW, PVI 95KW

Electric Actuator Installation, Operation & Maintenance Manual

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Positive Displacement Pump

Radian Research, Inc. makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use.

NECO Pumping Systems

General Installation Instructions for Valves and Gates

Air Curtain. Installation, Operating and Maintenance Instructions

Adjustable Purge Valve

Motorized Stainless 2-Way Valves

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

PRE-PLUMBED SEWAGE SYSTEM

Shuttle Type Switches For Moderate to High Liquid Flow Rates

FIXED DEPTH INSERTION METER INSTRUCTIONS

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

Miniature Liquid Level Sensors

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

INSTALLATION / INSTRUCTION MANUAL

APM Pneumatic Control for Boiler Feed System Applications

The Da-Lite Difference.

Installation & Operator s Manual

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

A48 / A48B (base plate) BATTERY CHARGER

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

INTRODUCTION INSTALLATION

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

SPC-PANEL Simplex, Single Phase Pump Control Panel

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Manual Transfer Switch

VIZUAL. Magnetic. Level. Indication. Installation and Operating Manual For the Magnetic Level Indicator (MLI) 7xxx. 6xxx. 5xxx. 4xxx. 3xxx. 2xxx.

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Swing-Flex Check Valve

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Service/Installation Manual Full Wall Slide Systems

Swing-Flex Check Valve

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Global Water Instrumentation, Inc.

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Installation Manual. Q Series Quadplex Grinder Systems. Contents

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

SUPERPLUS WATER FILTRATION SYSTEM

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Dome-Loaded Pressure Reducing BD-Series

Pressurized Bead Filters

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

Transcription:

L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 LIQUID LEVEL FLOAT SWITCH INSTALLATION AND OPERATIONS MANUAL Single-Point, Vertically-Mounted Liquid Level Float Switch L001 L002 L003 L170 L176 L180 L195 L190

READ THIS MANUAL PRIOR TO INSTALLATION This manual provides information on the L-Series, Single-Point, Vertically-Mounted Liquid Level Float Switch. It is important that all instructions are read carefully and followed sequentially. Detailed instructions are included in the Complete Installation section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data and safety information are presented in narrative form. The following styles are used for notes, cautions and warnings: Notes Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions and often follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component s mechanical integrity. Cautions are also used to alert the technician of unsafe practices, the need for special protective equipment, or specific materials. In this manual, a caution indicates a potentially hazardous situation which, if not avoided, may result in minor to moderate injury. Notice of Copyright and Limitations Copyright 2015 Solutions With Innovation, LLC; All rights reserved. Solutions With Innovation reserves the right to make changes to the product described in this manual at any time without notice. Solutions With Innovation makes no warranty with respect to the accuracy of the information in this manual. Warranty All Solutions With Innovation Mechanical Level and Flow Controls are warranted free of defects in materials and workmanship for one full year from the date of the original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation. Solutions With Innovation shall not be liable for misapplication, labor claims, direct or consequential damage, or expenses arising from the installation or use of the equipment. There are no other warranties expressed or implied, except special written warranties covering specific Solutions With Innovation products. Quality Assurance The Quality Assurance System in place at Solutions With Innovation guarantees the highest level of quality throughout the company. Solutions With Innovation is committed to providing full customer satisfaction; both in quality products and in quality service. Contacts Phone: 203-729-6434 Mon-Fri, 9 AM - 5 PM EST Fax: 203-729-0541 for General Inquiries Email: sales@innovativesensing.com 2 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH

L-Series: L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 AND L195 TABLE OF CONTENTS LIQUID LEVEL FLOAT SWITCH Single-Point, Vertical Mount 1.0 Installation 1.1 Unpacking...4 1.2 Before You Begin...4 1.2.1 Site Preparation...4 1.2.2 Equipment and Tools...4 1.3 Mounting...5 1.3.1 Threaded Mounting...5 1.4 Wiring...5 2.0 Preventative Maintenance 2.1 What To Do...6 2.1.1 Inspect Entire Unit Periodically...6 2.1.2 Inspect Connections Monthly...6 2.1.3 Keep Unit Clean...6 2.2 What To Avoid...6 3.0 Reference Information 3.1 Description...7 3.2 Theory of Operation...7 3.3 Troubleshooting...7 3.3.1 External Causes...7 3.3.2 Unit Causes...8 3.4 Agency Approvals...8 3.5 Specifications...9 3.5.1 Physical Specifications...9 3.5.2 Electrical Specifications...9 3.5.3 Dimensional Specifications...10 3.6 Notes...10 3.7 Model Configurator...11 3.8 Replacement Parts...11 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH 3

1.0 INSTALLATION This section provides detailed procedures on properly installing the L-Series Single-Point, Vertically-Mounted Liquid Level Float Switch. CAUTION! IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED. 1.1 UNPACKING Unpack the instrument, carefully. Make sure that all components have been removed from the packing material. Inspect all components for damage. Report any concealed damage to the carrier within 24 hours of receiving. Compare the contents with the packing slip and report any discrepancies to the factory immediately. Record the sales order number and/or serial number for future reference when ordering parts. Before Proceeding to Installation, Complete the Following: Inspect all components for damage. Report any damage to the carrier within 24 hours of receiving. Record the model and serial numbers for future reference when ordering parts. Model Number Serial Number 1.2 BEFORE YOU BEGIN CAUTION! DURING THE INSTALLATION OF THE SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL SWITCH, THE FLOAT AREA MUST BE KEPT FREE OF METALLIC PARTICLES THAT MIGHT BE ATTRACTED TO THE FLOAT S INTERNAL MAGNET. 1.2.1 Site Preparation Ensure that the length and the inside diameter of the mounting is sized correctly to accommodate the L-Series Single-Point, Vertically-Mounted Liquid Level Float Switch. 1.2.2 Equipment and Tools No special equipment or tools are required to install the L-Series Single-Point, Vertically-Mounted Liquid Level Float Switch. The Following Are Recommended: Wrenches, thread sealant, gaskets and/or bolting as required for the process connection. 4 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH

1.3 MOUNTING The L-Series Single-Point, Vertically-Mounted Liquid Level Float Switch is available in a variety of threaded mountings. These devices can be installed from the bottom or top of the tank. The switches should be mounted in an area clear of turbulence or direct streams. 1.3.1 Threaded Mounting How to Install an L-Series Single-Point, Vertically-Mounted Liquid Level Switch: 1 Apply either Teflon tape or an appropriate thread sealant to the mounting threads to prevent galling. 2 Engage the thread by hand to avoid unnecessary damage. 3 Using a wrench, rotate the unit clockwise until it is tight within the mounting. TOP MOUNT BOTTOM MOUNT 30 MAX. ANGLED MOUNT 1.4 WIRING CAUTION! OBSERVE ALL APPLICABLE ELECTRICAL CODES AND PROPER WIRING PROCEDURES. SPST Reed Switch: 1 Connect the wiring to the red switch leads or terminals, as illustrated below. RED RED SPDT Reed Switch: 1 Connect the wiring to the proper switch leads or terminals, as illustrated below. BLACK RED RED N.O. ORANGE NORMALLY-OPEN Dry Condition NORMALLY-CLOSED Dry Condition Dry Condition N.C. RED Contact Protection: In order to maintain the life and reliability of the internal reed switch, it is essential to provide protection when switching inductive loads. When the current breaks, the energy stored in the load generates a high frequency voltage across the switch contacts. If the voltage is large enough, it can initiate arcing and cause the contacts to weld together. Damage can ultimately be prevented by suppressing the voltage. Through the use of a diode for DC circuits and a resistor-capacitor network for AC circuits, contact protection will ensure reliable performance from the reed switch. L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH 5

2.0 PREVENTATIVE MAINTENANCE Periodic inspections are necessary to maintain the proper functionality of the L-Series Single-Point, Vertically- Mounted Liquid Level Switch. The switch is a safety device that protects the equipment it serves. A systematic program of preventative maintenance should be implemented at the time of installation. If the following instructions are completed routinely, the switch will provide continuous, reliable protection. 2.1 MAINTENANCE PROCEDURES 2.1.1 Inspect Unit Periodically Verify that there are no cracks or chipped surfaces on the float or stem. Should the unit become damaged, obtain a replacement immediately. 2.1.2 Inspect Connections Monthly L-Series Single-Point, Vertically-Mounted Liquid Level Switches may be vulnerable to excessive heat and moisture. Under these conditions, the electrical wire insulation can periodically break or peel away. As a result, the bare wires may become exposed to the elements and cause damages. Inspect all wiring, carefully and replace any wires exhibiting signs of brittle insulation. Inspect all electrical connections to ensure tightness. Repair or replace any wiring, if necessary. 2.1.3 Keep Unit Clean Periodic cleanings of the float, stem and magnet assembly will ensure the continual, uninterrupted movement of the mechanism. Always keep the open area between the enclosures clean and free of any potential interferences. Objects and debris may cause systematic interruptions and a loss in equipment functionality. 2.2 WHAT TO AVOID NEVER LEAVE THE SWITCH WIRING EXPOSED TO THE ELEMENTS. NEVER PLACE A JUMPER WIRE ACROSS THE TERMINALS TO CUT-OUT THE CONTROL. If a jumper is necessary for testing purposes, ensure that it is removed prior to placing the control into service. NEVER USE IN SYSTEMS CONTAINING IRON PARTICLES. The magnet within the float assembly can attract the particles and become jammed. 6 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH

3.0 REFERENCE INFORMATION This section illustrates an overview of the L-Series Single-Point, Vertically-Mounted Liquid Level Switch, as well as information on troubleshooting common problems, agency approval listings, and detailed physical, functional and performance specifications. 3.1 DESCRIPTION The L-Series Single-Point, Vertically-Mounted Liquid Level Switch is a float-actuated device designed to be vertically mounted within a tank or process vessel through threaded connections. The low-cost switch is ideal for OEM applications where a single-point high or low level alarm is desired. 3.2 THEORY OF OPERATION The switching action is achieved through the use of an internal magnet within the float assembly and its interaction with the switch mechanism. As the liquid level fluctuates inside the tank, the float follows. Its magnetic field actuates the switch inside the stem and closes an electrical circuit. FLOAT SWITCH DIAGRAM 3.3 TROUBLESHOOTING The L-Series Single-Point, Vertically-Mounted Liquid Level Switch is designed and engineered for troublefree operation over a wide range of operating conditions. Common problems are discussed in terms of their symptoms and recommended corrective actions. 3.3.1 External Causes An initial indication of improper operation is the failure of the controlled equipment to function (pumps will not start or stop, signal lamps fail to light, etc). If these symptoms occur, whether at the time of installation or during routine service thereafter, check for potential external causes first: Blown Fuses Tripped Reset Button(s) Open Power Switch Faulty Equipment Controlled By the Level Switch Defective Wiring to the Level Switch L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH 7

3.3.2 Unit Causes If a thorough inspection of any external causes fails to locate the problem, proceed to an inspection of the unit, itself. DISCONNECT POWER TO THE LEVEL SWITCH BEFORE PROCEEDING. SYMPTOM PROBLEM SOLUTION THE UNIT IS UNRESPONSIVE. ELECTRICAL FAILURE. USE AN ELECTRICAL CONTINUITY CHECKER TO DETERMINE IF THE SWITCH IS FUNCTIONAL. IF THE SWITCH DOES NOT OPERATE PROPERLY WHEN ACTIVATED, THE ENTIRE LEVEL SWITCH MUST BE REPLACED. THE UNIT DOES NOT ACTIVATE WHEN THE FLOAT CHANGES POSITION. THE UNIT IS JAMMED. REMOVE THE LEVEL SWITCH FROM SERVICE. CHECK THE FLOAT ASSEMBLY FOR OBSTRUCTIONS OR ACCUMULATION OF PARTICLES WHICH MAY CAUSE BINDING. IF BINDING IS PRESENT IN THE FLOAT ASSEMBLY AND CANNOT BE CLEARED BY NORMAL CLEANING PROCEDURES, THE ENTIRE CONTROL MUST BE REPLACED. THE UNIT ONLY FUNCTIONS WHEN IT IS NOT IN SERVICE. THE UNIT ONLY FUNCTIONS WHEN IT IS NOT IN SERVICE. THE FLOAT IS NOT BUOYANT. LIQUID IS NOT ENTERING THE VESSEL. THE TANK LEVEL IS NOT HIGH ENOUGH TO HAVE THE FLOAT FUNCTION. THE FLOAT IS COLLAPSED AND/OR FILLED WITH LIQUID. CHECK TO ENSURE THAT LIQUID IS ENTERING THE TANK OR VESSEL. A CLOSED VALVE OR CLOGGED PIPELINE MAY PREVENT MOVEMENT OF THE LIQUID IN THE VESSEL. CHECK THE FLOAT TO MAKE SURE IT IS BUOYANT IN THE LIQUID. THE TANK OR VESSEL MUST HAVE AN ADEQUATE LIQUID LEVEL. CHECK THE FLOAT FOR RUPTURES, DEFORMATION, AND ANY LIQUID TRAPPED INSIDE THE ASSEMBLY. IF THE FLOAT IS FILLED WITH LIQUID OR HAS COLLAPSED, THE ENTIRE LEVEL SWITCH MUST BE REPLACED. DO NOT ATTEMPT TO REPAIR THE FLOAT. ALL COMPONENTS WITHIN THE LEVEL SWITCH ARE IN WORKING ORDER, BUT THE UNIT STILL DOES NOT FUNCTION. AN EXTERNAL PROBLEM. REPEAT AN INSPECTION OF THE EXTERNAL CONDITIONS AS DESCRIBED IN SECTION 3.3.1. If you are still in doubt about the condition or performance of your control, consult the factory for further instructions. 3.4 AGENCY APPROVALS AGENCY APPROVED MODEL(S) FILE NUMBER AREA CLASSIFICATION UL L001, L002, L003, L170, L175, L176, L177, L178, L180, L190 & L195 E203716 RECOGNIZED UNDER UL508 MOTOR CONTROLLERS & NJ0T8 MOTOR CONTROLLERS 8 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH

3.5 SPECIFICATIONS 3.5.1 Physical Specifications MODEL PROCESS TEMP. MAX. PRESSURE FLOAT SPECIFIC GRAVITY RECOMMENDED MINIMUM LIQUID S.G. STEM MATERIAL FLOAT MATERIAL L001-40 to +150 F 150 PSIG 0.65 0.95 Polypropylene Polypropylene L002-40 to +150 F 150 PSIG 0.63 0.84 Polypropylene Polypropylene L003 L170 L175 L176 L177 L178 L180 L190-40 to +150 F 150 PSIG 0.65 0.87 Polypropylene Polypropylene -40 to +150 F 50 PSIG 0.49 0.66 Polypropylene Polypropylene -40 to +150 F 50 PSIG 0.74 1.00 PVC PVC -40 to +180 F 150 PSIG 0.47 0.63 Nylon Buna -40 to +180 F (In Water) -40 to +225 F (In Oil) 150 PSIG 0.47 0.63 Brass Buna 150 PSIG 0.47 0.63 Brass Buna -40 to +180 F 150 PSIG 0.47 0.63 Stainless Steel Buna -40 to +300 F 100 PSIG 0.52 0.69 Brass Stainless Steel -40 to +300 F 100 PSIG 0.52 0.69 Stainless Steel Stainless Steel -40 to +300 F 300 PSIG 0.74 1.00 Brass Stainless Steel -40 to +300 F 300 PSIG 0.74 1.00 Stainless Steel Stainless Steel -40 to +300 F 600 PSIG 0.72 0.96 Brass Stainless Steel -40 to +300 F 600 PSIG 0.72 0.96 Stainless Steel Stainless Steel -40 to +300 F 275 PSIG 0.65 0.86 Brass Stainless Steel -40 to +300 F 275 PSIG 0.65 0.86 Stainless Steel Stainless Steel -40 to +180 F 150 PSIG 0.48 0.64 Brass Buna -40 to +180 F 150 PSIG 0.48 0.64 Stainless Steel Buna -40 to +180 F 150 PSIG 0.43 0.57 Brass Buna -40 to +180 F 150 PSIG 0.43 0.57 Stainless Steel Buna -40 to +300 F 120 PSIG 0.60 0.80 Stainless Steel Stainless Steel -40 to +140 F 150 PSIG 0.43 0.57 PVC Buna L195-40 to +300 F 750 PSIG 0.59 0.79 Stainless Steel Stainless Steel 3.5.2 Electrical Specifications SIGNAL OUTPUT TYPE OF CONTACTS TYPE OF SWITCHES SWITCH RATING Switch Closure SPST, SPDT Hermetically-Sealed, Dry Contact Reed Switch 50 VA, 240 VAC/VDC Max. 100 VA, 240 VAC/VDC Max. 3 VA, 30 VAC/VDC Max. L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH 9

3.5.3 Dimensional Specifications MODEL THREAD SIZE HEX LENGTH HEIGHT DIAMETER STYLE HEX THREAD L001 L002 1/8 NPT 1/2 1.13 0.63 0.63 2 3/8-16 1/2 1.13 0.63 0.63 2 1/8 NPT 1/2 1.53 1.00 0.75 2 3/8-16 1/2 1.53 1.00 0.75 2 HEIGHT LENGTH L003 1/8 NPT 1/2 1.57 1.00 1.00 2 3/8-24 1/2 1.57 1.00 1.00 2 DIAMETER STYLE 1 L170 1/8 NPT 1/2 1.50 1.00 1.00 2 L175 1/8 NPT 1/2 1.50 1.00 1.50 2 L176 1/8 NPT 1/2 1.50 1.00 1.06 2 HEX THREAD L177 1/8 NPT 1/2 1.50 1.00 1.18 1 L178 1/8 NPT 1/2 1.65 1.25 1.03 2 L180 1/8 NPT 1/2 2.50 1.75 1.19 2 HEIGHT LENGTH L190 1/4 NPT 5/8 2.53 1.81 1.88 2 L195 1/4 NPT 5/8 2.53 1.62 2.06 1 STYLE 2 DIAMETER 3.6 NOTES 10 L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH

3.7 MODEL CONFIGURATOR TECHNOLOGY MODEL CONFIGURATION MOUNTING STEM/BODY FLOAT ELECTRICAL L Liquid Level Sensor 001 Sub-Compact Switch - Standard 01 1/8 NPT 01 Brass 02 Polypro (Hollow) 03 50 VA SPST 002 Sub-Compact Switch C Custom 02 1/4 NPT 02 Polypropylene 03 Polypro (Solid) 04 100 VA SPST 003 170 175 176 177 178 Compact Switch for High Volume Use Compact Switch for High Temperatures & Pressures Compact Switch for High Temperatures & Pressures Compact Switch for High Temperatures & Pressures Compact Switch for High Temperatures & Pressures Compact Switch for High Temperatures & Pressures 180 Large Switch 190 195 Intermediate Switch for High-Viscosity Liquids All Stainless Steel Spherical Switch 17 3/8-16 04 PVDF 04 PVDF 06 3 VA SPDT 18 3/8-24 05 PVC 05 PVC (Hollow) 08 316/316L S.S. 08 316/316L S.S. 18 Nylon 20 Buna-N L 0 0 1-0 1 0 2-0 3 0 3 3.8 REPLACEMENT PARTS STEM & SWITCH SUB-ASSEMBLY FLOAT RETAINING CLIP When Ordering, Please Specify: Model & Serial Numbers Name & Part Number of Replacement Part or Assembly All replacement parts are for standard models only. Contact the manufacturer for ordering assistance on all specially modified models (model numbers followed by a C ; i.e. L003C, L177C, etc.) L-SERIES SINGLE-POINT, VERTICALLY-MOUNTED LIQUID LEVEL FLOAT SWITCH 11

ASSURED QUALITY & SERVICE COST LESS Service Policy Owners of Solutions With Innovation products may request a return of the product, or any part of the product for complete rebuilding or replacement. Units will be rebuilt or replaced promptly. Products returned under the SWI Service Policy must be returned by prepaid transportation. Solutions With Innovation will repair or replace the product at no cost to the purchaser (or owner) other than transportation if: 1 Returned within the warranty period; and 2 Factory Inspection finds the cause of the claim to be covered under the warranty. If the problem is due to circumstances beyond Solutions With Innovation s liability, or is NOT covered by the warranty, there will be charges for labor in addition to the parts required to rebuild or replace the equipment. In rare cases, it may be expedient to ship replacement parts; or in extreme cases, an entire product before the damaged product is returned. If a quick replacement service is necessary, notify the manufacturer of the damaged product s model and serial number. In such cases, credit for the returned materials will be determined on the applicability of the warranty. Return Material Procedure In order to efficiently process any returned materials, it is essential that a Return Material Authorization (RMA) number be obtained from the manufacturer prior to an item s return. RMA s can be issued through local representatives, or by contacting the factory directly. Please supply the following information: 1 The Company s Name 2 Description of the Material 3 Product Serial Number 4 Reason for Return 5 Product s Application Used units must be properly cleaned in accordance with OSHA standards before it is returned to the manufacturer. A Material Safety Data Sheet (MSDS) must accompany units or materials that were used in any type of media. All return shipments to the factory must be by done via prepaid transportation. All product replacements will be shipped F.O.B. manufacturer. No claims for misapplication, labor, direct or consequential damage will be allowed. BULLETIN: IS-9110.2 EFFECTIVE: 1/15