NEW Explosion protection

Similar documents
Catalog DRE Gearmotors (IE2)

Gearmotors \ Industrial Gear Units \ Drive Engineering \ Drive Automation \ Services. Gearmotors A3.D01. Catalog. Edition 04/ / EN

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Catalog. Variable Speed Gearmotors. Edition 08/2004 A3.D / EN

Catalog. Industrial Gear Units of the MC... Series. Edition 04/2005 D3.B / EN

Manual. DR.., DRN.., DR2.., EDR.., EDRN.. AC Motors Project Planning for BE.. Brakes Standard Brake/Safety Brake * _0818*

4 Overview of types and unit designation

Edition. DTE / DVE Energy Efficient Motors 10/2003. Catalog / EN

Catalog. Servo Gearmotors (R, F, K and S Gear Units) Edition 01/2005 DB / EN

Industrial Gear Units: Bucket Elevator Drives of the MC... / M... Series

7 Important information on selection tables and dimension drawings

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

2 Important Information, Tables and Dimension Sheets

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Motors and drives for applications in explosive atmospheres

8 Important Information about Tables and Dimension Sheets

VALIADIS S.A. HELLENIC MOTORS

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

Always on the safe side: Reliable plant operation with explosion-proof gear units, motors and geared motors

INSTRUCTION MANUAL (ATEX / IECEx)

Low voltage motors for hazardous areas Safe, reliable and highly efficient

Sensor boxes SRBE Key features and product range overview

INSTRUCTION MANUAL (ATEX / IECEx)

AC motors DR J (LSPM technology) / DRL / DRK / DRM

4 Project planning for drives

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Drive Technology \ Drive Automation \ System Integration \ Services. Catalog. Gear Units

Drive Technology \ Drive Automation \ System Integration \ Services. DR, CMP Motors. Catalog. Edition 09/ / EN

Ex m Solenoid Operator Type 0519

BROCHURE. Low voltage motors and drives for applications in explosive atmospheres

EU Regulation for Premium Efficiency IE3 motors 2, 4, 6 poles efficienza

Safety Standards. Model Number:

Load and Motor Switches, Load-Break Switches Series 8549

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

7 Selections and dimensions - Overview

* _1217* Drive Technology \ Drive Automation \ System Integration \ Services. Catalog. AC Motors DRN80 315

SIMOTICS Frei verwendbar / Siemens AG Alle Rechte vorbehalten.

Latest news. Explosion-Proof AC Motors EDRN According to Class Division System (HazLoc-NA ) * _0416*

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

Modular DR motor concept: Standard AC motors and energy-efficient motors of efficiency class IE

Technical Data. Dimensions

Load disconnect switch Series 8146/5-V11

Position Switches Series 8060/2

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Modular Flameproof Brakes

Position Switches Series 8070/2

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

EX-D ENCLOSURES AND DISTRIBUTIONS

OPERATING INSTRUCTIONS

SERIES R - MD MOR & GOR

Catalog. Brochure. Baldor explosion proof AC and DC Motors. Catalog

Terminal Boxes in Stainless Steel SLS**.T

5 Project Planning for Gear Units

High voltage flameproof induction motors The simplest solution for hazardous environments

Flameproof Alternators

EStrong-series Emergency Stop

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Observe the explanations and notes in this chapter during drive selection.

HTSB system System overview

Modular Explosion Proof Brakes. IECLine rev 0

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Explosion protected hydraulic products. Product overview industrial and mobile hydraulics

7 Important Information on Selection Tables and Dimension Sheets

Control Buttons / Switches for Panel Mounting Series 8003

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

Load and Motor Switches, Load-Break Switches Series 8544

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Terminal Boxes Series 8125

COMBUSTION AND ENERGY

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

Linear Luminaire with LED Series EXLUX 6402/2

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

AUTOMATISIERUNGSTECHNIK ENGINEERING INDUSTRIEHANDEL INDUSTRIESERVICE TECHNIK. Blumenbecker Service-Nr.: /

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Drive technology for the chemical industry. chemical INDUSTRY

Operating Instructions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Operating Instructions

Geared motors for use in Zone 22 - Category 3D

Plug and Socket Devices SolConeX 16 A Series 8570

THE NEW UNDEROIL SERIES ONLY 110mm Ø UNIQUE WORLDWIDE. AC Motors for Hydraulic Powerpack motors - Underoil motors

2 Product description

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

ILED Dorado. User Manual

Centrifugal fan with highly efficient EC drive motor

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Leading the way in hazardous areas Features EATON

Transcription:

Standard gear units / standard gearmotors according to ATEX and IECEx EDRE motors meet the efficiency class according to IEC 60034-30 making them suitable for use worldwide Compliance with efficiency levels required in many countries according to the local MEPS requirements The gearmotors/brakemotors meet the requirements of EU Directive 94/9/EC, IECEx, and soon also of ccsaus Available as gearmotor/motor in IECEx according to EPL Gb and Db as well as Gc and Dc Available as gearmotor/motor in ATEX in categories 2G, 2GD and 3GD, 3D for zones 1/21 and 2/22 In catagory 3 also available as brakemotor SEW-EURODRIVE has been audited and certified to 94/9/EC EDRS and EDRE motors as well as SEW-EURODRIVE have been audited and certified by PTB according to IECEx Certified Equipment Scheme with ExTr, QAR and CoC; the certificates are available at http://iecex.iec.ch Operation on a frequency inverter, also in the field-weakening range, for categories 2 and 3, and EPL.b and c respectively Approvals for the motor were performed according to the latest European standards applicable to explosion protection: General requirements IEC/EN 60079-0, gas IEC/EN 60079-7, IEC/EN 60079-15 and dust IEC/EN 60079-31 Compliance with the internationally applicable Equipment Protection Level EPL EDR motors comply with the most important standards and meet IEC motor standard 60034 Gear units according to ATEX meet standards EN 13463-1, 5 and 8 Same compact and power-oriented characteristics as the standard drives

Standard gear units / standard gearmotors according to ATEX and IECEx Gearmotor performance range Category / zone Type Power range [kw] II3G T3 II3D IIIB IIIC / 120 C / 140 C Zone 2 / 22 Helical gearmotors R..II2GD.EDR../3GD* Parallel shaft helical gearmotors F..II2GD.EDR../3GD* Helical-bevel gearmotors K..II2GD.EDR../3GD* DR 63**: EDR 71 225: DVE 250 280*: 0.25... 45 55... 75 Helical-worm gearmotors S..II2GD.EDR../3GD* DR 63**: EDR 71 200: 0.25... 22 SPIROPLAN gearmotors W..II2GD.EDR../3GD* DR 63**: EDR 71 132: 0.25... 4 II2G T3 II2D IIIC / 120 C Zone 1 and 21 Helical gearmotors R..II2GD.EDR../2GD* Parallel shaft helical gearmotors F..II2GD.EDR../2GD* Helical-bevel gearmotors K..II2GD.EDR./2GD* edr 63**: EDR 71 225: 0.25... 37 Helical-worm gearmotors S..II2GD.EDR../2GD* EDR 71 200: 0.25... 22 SPIROPLAN gearmotors W..II2GD.EDR../2GD* EDR 71 132: 0.25... 4 * Motors are labeled as follows: 3GD for ATEX / 3GD-c for IECEx, 2GD for ATEX / 2GD-b for IECEx (IECEx: Explosion-proof gear unit design not mandatory) ** According to ATEX only Motor performance range Category Zone Type 4-pole IE class Power range [kw] II3G T3 II3D IIIB IIIC / T120 C / T140 C 2 22 DR 63* EDRS 71 80 EDRE 80 225 DVE 250 280* 0.25... 0.55 0.75... 45 55... 75 II2G T3 II2D IIIC / T120 C 1 21 edr 63* EDRS 71 80 EDRE 80 225 0.25... 0.55 0.75... 22 II2G T4 1 EDRS 71 80 EDRE 80 0.25... 0.55 0.75 II2D IIIC / T120 C 21 * according to ATEX only

Standard gear units / standard gearmotors according to HazLoc-NA In addition to efficiency class according to IEC 60034-30, EDRE motors meet the requirements according to EISA 2007 and CSA C390-10 for the North American market and in this way also meet the requirements of many other countries that recognize these standards The motors are certified according to the class division system making them compliant with the explosion protection requirements of the North American market Available as gearmotor/motor, type /CID2, for divison 2 class I for gas groups A, B, C and D Available as gearmotor/motor, type /CIID2, divison 2 class II for dust groups F and G Available as gearmotor/motor, type /CICIID2, for divison 2 class I for gas groups A, B, C and D, and class II for dust groups F and G Also available as brakemotor with holding function SEW-EURODRIVE is certified according to UL and CSA Operation on a frequency inverter, also in the field-weakening range, possible in both classes The same compact and power-oriented features of the standard drives are provided On request, the motors are also possible with gear unit according to ATEX (EU-RL 94/4/EC)

Standard gear units / standard gearmotors according to HazLoc-NA Gearmotor performance range Division 2 Type Power range [kw] Class I Groups A, B, C and D T3 for operation on FI T3C for operation on the grid Class II Groups F and G Helical gearmotors R..EDR../C..D2 Parallel shaft helical gearmotors F..EDR../C..D2 Helical-bevel gearmotors K..EDR../C..D2 EDR 71 225: 0.18... 45 Helical-worm gearmotors S..EDR../C..D2 EDR 71 180: 0.25... 22 SPIROPLAN gearmotors W..EDR../C..D2 EDR 71 132: 0.25... 4 Motor performance range Division 2 Type 4-pole IE class Power range [kw] Class I Groups A, B, C and D T3 for operation on FI T3C for operation onn the grid EDRS 71 80 EDRE 80 225 0.18... 0.55 0.75... 45 Class II Groups F and G Operation on the inverter Operation of EDRE motors according to HazLoc-NA on SEW frequency inverters has been thoroughly tested Whether star, delta or double star, MOVITRAC and MOVIDRIVE inverters can be operated up to 3000 rpm Operation is possible in class I as well as in class II in division 2 Power reduction is not necessary Operation on non-sew inverters is also possible taking account of the derating curves up to a line voltage of 500 V

Explosion-protected asynchronous AC motors categories 2 and 3 (94/9/EC) in combination with frequency inverters Categories Overview of the advantages of this combination over asynchronous AC motors in explosion protection type d (EN 60079-1; flameproof enclosure): High efficiency Lighter weight Shortest possible delivery times, high availability Certified for operation with SEW frequency inverters Suitable for pump and fan drives Delivery from a single source, from a manufacturer that offers both components itself Higher speeds Strict adherence to guidelines is particularly important in areas with potentially explosive air/gas and gas/dust/air mixtures. Thanks to many years of experience and competency in this area, SEW-EURODRIVE ensures that the relevant guidelines are observed. Furthermore, the company s expertise is continually being expanded to include new and further developments. The 4-pole motors from SEW-EURODRIVE in category 2 and 3 are also suited for operation on frequency inverters Category 2 is certified by prototype testing Brakemotors are available in category 3 The suitability for operation on inverters is confirmed on the nameplate A second nameplate provides all the information required for operation Zone Motor type Protection type MOVITRAC B MOVIDRIVE B MOVIMOT 1 EDR../2GD "e" (EN 60079-7, increased safety) * 2 EDR../2GD "na" (EN 60079-15, non-sparking) 21 EDR../3GD "tb" (EN 60079-31, dust explosion protection) 22 EDR../3GD "tc" (EN 60079-31, EDR../3D dust explosion protection) * * * * * * * also in the field-weakening range

Safe operation of category 2 and 3 motors on frequency inverters Project planning Technical data The extensive product range of SEW-EURODRIVE inverters is available for designing electronically controlled drives: MOVITRAC MC07B: Compact and inexpensive frequency inverter for the power range 0.25... 75 kw. 3-phase line connection for AC 380... 500 V. MOVIDRIVE MDX60/61B: High-performance drive inverter for dynamic drives in the power range 0.55... 250 kw. Great diversity of applications due to extensive expansion options with technology and communication options. 3-phase line connection for AC 380... 500 V. MOVIMOT is the success product in decentralized drive engineering: the ingeniously simple combination of a gearmotor and a digital frequency inverter. MOVIMOT category 3D are the synthesis of EDR. motors and integrated frequency inverter. These types are specifically designed for use in areas with potentially explosive dust/air mixtures (zone 22) and are available in the power range of 0.25 kw to 3 kw, with or without brake, for supply voltages of 400 V to 500 V. Project planning is the basic requirement for the safe operation of explosion-proof motors. Motors in categories 2 and 3 meet the requirements for equipment intended for use in potentially-explosive areas as defined in directive 94/9/EC (ATEX 95). A device for direct temperature monitoring in combination with the defined parameters of the frequency inverter offers the best possible protection against excessive heating caused by overload. EDR motors 230 / 400 V Connection Star Delta P line [kw] M FI [Nm] M FI [Nm] Category 2G / 2D 0.25 37 1.7 240 1.7 240 Category 3G / 3D Category 3D with MOVIMOT 0.25... 3.0 1.7... 20.5 1.2... 9.9 For frequency inverter operation, there is no reduced load value in relation to the nominal line torque to ensure thermally safe operation as is often usual.