series 260 LAS 260 HD FK

Similar documents
(ULT300-UM.x-HFM050) Technical Documentation

(ULT200-UM.x-HFM050) Technical Documentation

TFS 1000 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY

200-SERIES EXTRACTION

JUMBO. Fume Extraction Technology. Compact and Versatile. Filtertrolley 2.0. Extraction. Filtration. Persistence.

FP 200-SERIES. Precoating (applying a separating layer to the filter cartridge) enables the system to reliably filter out even sticky and moist dust.

FP 150 EXTRACTION / FILTER / POLLUTION CONTROL // TECHNOLOGY. Similar to image VN-8-02

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

PRODUCT BROCHURE Universal duct air filter DELBAG MultiClean. One system, many solutions

DESKTOP CONTAINMENT SYSTEM

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

The BVX-100 Fume Extraction System

Smart Fume Extractor

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

PRODUCT GUIDE Version 2004:02 For a better workbench environment

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Smart Fume Extractor

Fume Extraction. 22 o C DIGITAL RANGE. 250 m 3 / hr BROCHURE

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

TRIVAC NT 16 and NT 25

Operating instructions

THE WORLD OF EXTRACTION. Series EXTRACTION TECHNOLOGY FOR MAXIMUM EFFICIENCY

OPERATIONAL INSTRUCTIONS

Bench Top Extraction Arms

C02 SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

Videojet Fume Extractor Preventive Maintenance Guide

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

quatroair.com AIR TECHNOLOGIES INC.

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BTX-208. Fume Extraction System _B

Air Boss M-Series Media & Adsorption Air Cleaner

OPERATIONAL INSTRUCTIONS

Fume Extraction. 150 Fume Extraction

Fume Extraction Planning Guide

MODEL FA5 Air Filtration System. Operations Manual

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)

Volume Extraction Extraction Units

HENALINE. A complete line of single-stage rotary vane pumps for low and medium vacuum applications. Safe. Reliable. Powerful.

About Dustcontrol Filter Units

Affordable portable filtration unit

Leadership in Filtration. ENTARON HD Highest application flexibility through innovative evolution

Technical specification agenitor 306 NG

Piston Compressors. Volume range: l/min

Ductless Nanoparticle Containment Enclosures

MG200 Filter system OPERATING INSTRUCTIONS FOR A BETTER WORKBENCH ENVIRONMENT FILTRONIC

Technical specification agenitor 404b NG

Technical specification agenitor 408 NG

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

VORTICENT C E RANGE Centrifugal fans

AXIAL FANS Catalogue CN0050C01 May 2008

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

MOBILAIR M 125. Portable Compressor With the world-renowned SIGMA PROFILE Max. flow rate 11.5 m³/min (405 cfm)

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

PLANNING THE INSTALLATION

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

FILTER MODULES FILTER MODULES APPLICATIONS

MOBILE PURE AIR DUST EXTRACTORS AL-KO POWER UNIT

Weller Info No. 2. New in Weller Volume Extraction System WFE2ES

MOBILAIR M 135/M 170/M 171. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 10.5 to 17.0 m³/min ( cfm) COMPRESSORS

Bio II Advance. Class II Biological Safety Cabinet

H) OIL MIST FILTRATION

KSI Filtertechnik GmbH Siemensring D Willich Tel Fax

5 Compact Vacuum Systems. Compact Vacuum Systems

GMK EV SERIES. Single Stage Oil Sealed Rotary Vane Pump

Why Fume Extraction? Lead-Free Solders Are The Worst

epilog fume extraction solutions

Oil Mist Separator Unit LGA 1200 FU/FUW

Flammable. cabinets. Corrosive. cabinets. Toxic cabinets. and multirisk. Pesticide range. Fume hoods, filtering. cabinets - Ventilation

Centrifugal fan with highly efficient EC drive motor

Brochure 01/13. Protecting People and the Environment with Innovative Technology

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

Portable HEPA System

Ventilated Balance Enclosures

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

Filter Efficiency 380 x 260 x m³/h Centrifugal Fan phase % Duct Size mm. Duct Run mtrs. Dimensions (HxDxW) Weight Kg

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

Filters for fixed installations

ambiente wood burning stoves

AIR CLEANERS OF OIL MIST FUME AND DUST FOR MACHINE TOOLS

Assembling and testing of a flameless burner

FUEL STATION FOR INTERNAL USE KA

Safety drying ovens with expanded temperature range

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

Catalogue of Accessories

KARL SCHNELL GRINDER SPECIFICATION: KS Process Automat B 22 Type l

Product catalogue 2010

Safety drying oven with expended temperature range

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Pressure switch for gas, GW 500 A4 GW 500 A4/2

SF-1000 workbench - welding table. User s Manual.

Product series DigitalSuper

FilterMax F. Modular dust collector with integrated pre-separator. Models

MOBILE PURE AIR DUST EXTRACTORS AL-KO POWER UNIT

Nexa 1200 Fuel Cell System

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Data sheet. KRTF /24XEG-S IE3 Version no.: 3. Operating data. Design. Driver, accessories

MANN+HUMMEL IQORON The new compact air cleaner for high requirements

EQUIPMENT. Loctite Bench Top Air Filtration System Plenum Style Part Number Air Filtration System With Arm Part Number

Transcription:

series 260 Date of issue: 11/2013 Extraction. Filtration. Persistence.

Use and application The is suitable for collecting and filtering dry and non-combustible types of dust contained in non-explosive air mixtures produced during laser machining. Any emitted and partially unhealthy types of dust,, fumes and gases ought to be extracted by collecting elements directly at their place of origin and filtered by the. The innovative filter concept offers a significantly larger filtering surface and reduces the occurring maintenance costs thanks to the huge storage capacity. A thick layer of activated charcoal enables a long contact time with the contaminated air flow. Gases and fumes are adsorbed effectively. Examples laser cutting, laser engraving, laser structuring laser processing of metal, plastic or organic material ULT 260 mobile extraction and filtration unit mobile unit with castors with filter replacement system all interfaces on the back side control panel and access to filter elements on the front side easy filter handling robust steel housing powder coated RAL 7047 tele gray Filter system: Storage filter system Filters which are replaced once they are saturated. Filter technology: (1) Particle filter cassette F9 filter class: F9 fine dust filter according to DIN EN 779 (2) Combined filter cassette H14A10 (2.1) Particle filter H14 filter class: (2.2) Adsorption filter A10 Configuration H14 HEPA-filter according to DIN EN 1822 filter medium: activated charcoal (ca. 10 kg) Air flow controller: Loaded particle filter indicator: suction power is continuously adjustable visualization of the particle filter condition

LAS 260.0-HD.16.1 HD.16.10.5014.5014 Parameter unit -HD.16.10 Max. air flow m³ / hr 200 Max. vacuum Pa 22.000 Nominal capacity m³/hr / Pa 120 / 12.000 Motor-nominal power kw 1,20 Nominal voltage V 230 Nominal current A 10 Frequency Hz 50 / 60 Protection class IP 54 Type blower EC-Turbine Noise level (at 50-100%) db(a) 60-70 Air flow controller yes Loaded particle filter indicator optical yes SUB D9 interface optional Air intake 1x Ø 80 mm nozzle position upper part of the backside Air outlet air exhaust louver, optional Ø 100 mm exhaust nozzle position lower part of the backside Width mm 460 Depth mm 475 Height mm 975 Weight kgs 75 Length of power cable m 3,0 Filter system filter set consisting of: (1) Particle filter cassette F9 ULT 02.1.711 Combined filter cassette H14A10: (2.1) Particle filter H14 ULT 02.1.721 (2.2) Adsorption filter A10 unit with option SUB-D9 and exhaust air louver from the back:

Functional principle: At the clean-air side of the filter, a turbine with a high pressure reserve produces a volume flow matched to the respective application. This volume flow can be individually and infinitely variably regulated. Thus, the polluted air will be reliably extracted. The particles are separated and held back at the first filtration level in multiple stages. Gaseous and vaporous air pollutants are separated (adsorbed) in an activated charcoal filter. The filtering effect of activated charcoal is based on adsorption, i. e. an accumulation of substances (to be filtered out) on the surface of the activated charcoal. During this process there are no chemical reactions and changes of the captured substances. The construction of the filter elements underlies the volume flow of the unit; the contact time is based on a medium adsorption reaction. The filter combination can be accessed through the front door. Thanks to the user-friendly design of the filter space the replacement of the filter elements requires little effort. raw gas filtration clean gas Storage filter system Filters which are replaced once they are saturated. Pre-filtration cassette (1) fine dust filter Particle filter F9 Combined filter cassette (2.1) particulate filter HEPA filter H14 (2.2) Gasfilter Adsorption filter A10 (10 kg activated charcoal) This excellent filter efficiency makes it possible to recirculate the filtered air and reduce energy costs.

A air intake nozzle DN80 867 80 O 975 Fine dust filter F9 Combined filter cassette H14A10 HEPA H14 + 10 kg activated charcoal integrated sound absorber housing exhaust air louver A 24 348 cutaway A-A High pressure turbine with EC-drive 475 air flow controller loaded particle filter indicator D detail D on/off switch 440 460 Allgemeintoleranzen DIN ISO 2768-mK Weitere Maße sind dem 3D-Datensatz zu entnehmen. Für die Zeichnung behalten wir uns alle Rechte vor. Other measure are to be taken from the 3D record. For the drawing we reserve ourselves all rights. ULT AG designation: Am Göpelteich 1 D-02708 Löbau 002 Designübern. 08.10.13 A. Rei 001 Maße 28.06.13 A. Rei 000 Basis Dok 26.04.13 A. Rei issue revision day name 2013 date name drawing number: edit. 26.04. A. Reichmann veri. Norm / 120 m³/h-vf scale: ULT260_00_001_ 001 1 : 10