Crosby Style JQ pressure relief device

Similar documents
Crosby Style JQ pressure relief device

Crosby Style JQ Pressure Relief Device. Flow Control

* Contact your sales representative for compliance to NACE MR or later requirements.

CROSBY J-SERIES DIRECT SPRING PRESSURE RELIEF VALVES

* Contact your sales representative for compliance to NACE MR or later requirements.

CROSBY STYLE JB PRESSURE RELIEF VALVE

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Series Low Pressure Steam Heating Boiler Safety Valves

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

CASH VALVE SERIES FR BACK PRESSURE VALVES

Kunkle Models 189/363/389 safety valves Safety and relief products

Pressure Relief Valves Series. Consolidated Safety Valve

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

Series Low Pressure Steam Boiler Safety Valves

CASH VALVE B SERIES PRESSURE REGULATORS

KUNKLE MODELS 19/19M/20/20M/20P/20MP/200A/200H LIQUID RELIEF VALVES SAFETY AND RELIEF PRODUCTS

MERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

Kunkle Bailey 756 safety relief valve

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

1541/1543 Series. Consolidated * Valves. Safety Valve

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

Kunkle Models 91/218/228 liquid relief valves Safety and relief products

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

The Universal Sewer Air Release Valve is designed to permit

SV80H Safety and Relief Valves

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.

ZAP * & KBA Reverse Acting Rupture Discs

ANDERSON GREENWOOD LOW PRESSURE POPRV CATALOG SERIES 90 AND 9000 PILOT OPERATED PRESSURE RELIEF VALVES. Product overview

SAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include

High performance safety valve for the protection of large boilers and superheaters, certified to ASME Section I.

KunKle SAFETY AND RELIEF VALVE PRODUCTS OVERVIEW

KUNKLE Safety and Relief ValVe PRoductS overview

MERCER VALVE GENERAL INFORMATION

627 Series Pressure Reducing Regulators

Type B TM Rupture Disk. Type. Solid Metal Rupture Disks. BSBsystems.com BSB.ie Visit our website for the most complete, up-to-date information

Type 441 CATALOG. Flanged Safety Relief Valves. The-Safety-Valve.com

Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/

R627 High Flow Gas Regulator with Internal Relief

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

P200 Pressure Regulator

Models 912, 913, 918, 919 ASME Section VIII, Steam/Air/Gas/Liquid, UV National Board Certified. Also available for Vacuum Service.

MERCER VALVE SERIES Flanged THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Y690A Series Pressure Reducing Regulators

AN ISO 9001:2008 CERTIFIED COMPANY. Safety Valve

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

Wafer Silent Check Valves

394C. Series 6400/6600. Safety Valves for Power Boiler Service

Anderson Greenwood Low Pressure POPRV Catalog Series 90 and 9000 Pilot Operated Pressure Relief Valves

flow orientation between the companion flanges. Both the J-Hook and alignment pins are provided on all 1" through 12" UNISERT Holders.

CASH VALVES TYPE G-4 PRESSURE REGULATORS

Safety and Relief Valves Product Overview

Consolidated* Series

Kunkle Safety and Relief Products Models 6252 and 6254

Safety Relief Valves Commanche Techmatic Controls

BIRKETT SAFESET SERIES PILOT OPERATED SAFETY RELIEF VALVES

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

P200 Pressure Regulator

Crispin. The UL Series Universal Air Release Valves. Compound Lever System NPT Screwed or ANSI Class Flanges Available.

CASH VALVES TYPE G-60 PRESSURE REGULATORS

Crispin Valves Operating Guide. Crispin

Type 459. Type. 459 Safety Relief Valves spring loaded

Model descriptions. Technical data. Pressure and Temperature Limits Model 6252: 10 to 250 psig [0.7 to 17.2 barg] -20 to 406 F [-28 to 208 C]

Hopkinsons CONTENTS SCHEDULE OF SHELL BOILER MOUNTINGS. Hopkinsons. Safety Valves 5. Boiler Stop Valves 17. Feed Check Valves 18. Blowdown Valves 20

SLK SERIES SAFETY VALVES

P200 Pressure Regulator

Yarway Hy-Drop Throttling valve

Consolidated* 3900 MPV Series Pilot-Operated Safety Relief Valve

TOSACA. Catalogue

P627 High Flow Gas Regulator

CS800 Series Commercial/Industrial Pressure Reducing Regulators

These PFA and PTFE lined products offer a reliable solution in hazardous applications

API CATALOG. Flanged Safety Relief Valves Series 526. The-Safety-Valve.com

ANDERSON GREENWOOD SERIES 9290 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Capacity Charts. Direct Spring Acting Safety Relief Valves for Air, Gas, Liquid, and Steam Service

Type 441 DIN 442 DIN. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. US Units

T200 Pressure Regulator

R627 High Flow Gas Regulator with Internal Relief

High. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

Compact. Performance. Safety Relief Valves Series 437 Series 459. The-Safety-Valve.com

Table of Contents Scope of Design

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

2900 MPV Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

MERCER VALVE SERIES Threaded THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

VALFONTA SELF-ACTING PRESSURE REDUCING VALVE M1

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

SECTION VALVES PART 1 -GENERAL

Model descriptions. Technical data. Pressure and Temperature Limits Models 19, 20, 20P: -60 to 406 F Models 19M, 20M, 20MP:

cs200 series commercial / Industrial pressure reducing regulators

Transcription:

A combination pressure relief device designed with internal parts completely isolated from corrosive fluids and environments Features Designed in collaboration with the Chlorine Institute, Inc. Provides reliability and safety beyond that possible with a conventional pressure relief valve. Inlet and outlet diaphragm seals effectively prevent the corrosion of internal working parts and the escape of fugitive emissions. Choice of 1½ and 4" (38 and 100 mm) inlet sizes. 1½ (38 mm) model equipped with a special Chlorine Institute-approved inlet flange and metal-to-metal seat. Optional 1½ 300 lb ANSI raised face flange adapter and elastomer O-ring seat available for exceptional tightness. 4" (100 mm) model standard with 4" 300 lb ANSI large tongue-faced inlet flange and metal seat Raised-face flange available as an option. Association of American Railroad Approval Nos. SRD-989034 and SRD-989035. General application Designed to provide dependable overpressure protection for vessels used for the transportation and storage of chlorine and other dangerous commodities, these unique valves are in use worldwide on railroad tank cars, barges and stationary vessels. Technical data Inlet sizes: 1½ and 4" (DN 40 and DN 100) Pressure limits: 1½ (DN 40): 450 psig (31 barg) 4" (DN 100): 375 psig (25.8 barg) Temperature range: -20 to +250 F (-29 to +121 C) www.valves.emerson.com 2017 Emerson. All rights reserved. VCTDS-00291-EN 16/02

Operation The Style JQ is a combination pressure relief device comprising a standard spring loaded valve with a breaking pin assembly protected by a diaphragm. The breaking pin assembly is installed as a complete unit in the valve inlet and forms the gasket face for the mounting flange. The inlet to the breaking pin housing (28) is sealed by the corrosion-resistant diaphragm (30) which is supported by the plunger and columns (24), yoke (22) and breaking pin (23). The pressure load on the diaphragm is carried through the plunger and columns to the yoke and thus to the breaking pin, which is a tensile member designed to break at a predetermined inlet pressure. It is held in place by two U-shaped clips (26). A positive seal is formed by the diaphragm, which is clamped by the follower (29) and spanner nut (25). This keeps the corrosive fluids away from the seating surface of the valve until, at a specific pressure within the containing vessel, the pin is broken. For severe corrosive fluids, in addition to the standard lead diaphragm, the following diaphragm materials are available: - Platinum backed with lead - Gold backed with lead - Silver backed with lead - FEP backed with lead - Nickel backed with lead (for pressures of 225 psig (15.5 barg) and up) The internal working parts of the valve are also protected from ambient atmospheric conditions by the upper diaphragm (2) which is clamped in place by the cap (1). When the pin fractures, the valve instantly pops fully open and the upper diaphragm is broken automatically to permit free discharge from the valve. After an overpressure event and return of inlet pressure to safe working pressure, the valve will reseat with normal blowdown and function as a pressure relief valve until it is convenient to replace the breaking pin and upper/lower diaphragms. This saves valuable fluid and ensures maximum safety to personnel and equipment. Design variations The JQ is manufactured to ASME Code Section VIII, both as a pressure relief valve alone and as a combination relieving device. As a combination device, it is available with either the breaking pin mechanism or with a rupture disc device (not shown). For ASME Code applications with a rupture disc installed between the valve and the protected vessel, the stamped capacity of the valve must be multiplied by a factor of.90 or by a combination capacity factor obtained through certification testing. When the JQ is to be installed in accordance with ASME Boiler and Pressure Vessel applications, the style is designated as JQU. For ASME Code installations when a rupture disc or breaking pin assembly is installed between the vessel and the JQU, it is mandatory that the space between the rupture disc or breaking pin assembly and the JQU valve is provided with a pressure gauge, a try cock, free vent or other suitable tell-tale indicator. A ⅛ 27 NPT tapped hole is provided in the valve base to meet this requirement. Users, architect engineers and installers are cautioned to provide for safe disposal of fluid from this vent in the event of diaphragm leakage and/or diaphragm rupture. Additionally, to ensure that the valve and the non-reclosing device will function correctly, the set pressure of the valve must be the same or lower than that of the breaking pin or rupture disc used in combination. The standard JQ normally relieves to atmosphere with no provision for outlet piping. Other designs are available for venting to a closed exhaust system. The JQ valve is available in an all Monel construction for applications requiring maximum corrosion resistance of internal parts. Contact your sales representative for design variations or special material valves. 2

Chlorine transportation service Inlet size (inch) Style Spring inlet flange Breaking setting (psi) Pin set (psi) Air capacity (SCFM) Service Jurisdictional agencies 1½ JQ-225 Chlorine Institute 213 225 2700 at 225 psi Tank car Chlorine Institute, Inc.; AAR flange [1] 1½ JQ-375 Chlorine Institute 360 375 4395 at 375 psi Tank car Chlorine Institute, Inc.; AAR flange [1] 4 JQ-300 300 lb ANSI tongue faced 300 300 15,350 at 10% accumulation Barge tank Chlorine Institute, Inc.; U.S.C.G. General service Inlet size Spring inlet Breaking setting Pin set Air capacity (inch) Style flange (psi) (psi) (SCFM) Service Jurisdictional agencies 1½ JQU-1 Chlorine Institute 30-225 30-225 See page 5 Pressure vessel storage ASME flange [1] and transportation 1½ JQU-2 Chlorine Institute 226-375 226-375 See page 5 Pressure vessel storage ASME flange [1] and transportation 4 JQU 300 lb ANSI tongue faced 30-350 30-350 See page 5 Pressure vessel storage and transportation ASME and U.S.C.G. Note 1. 1½ 300 lb ANSI raised face adapter optional. Figure 1 Figure 2 1 2 31 Optional O-ring soft seat Figure 3 22 26 Tell-tale Tell-Tale connection Connection 23 24 29 28 30 25 Optional 1½ 300 lb ANSI flange adapter 3

Parts and Materials No. Part Material 1 Cap - 1½ valve 316 SS Cap - 4 valve Ductile iron 1 2 2 Diaphragm (upper) [1] 3% antimony lead [1] 3 Adjusting bolt Monel Spring - 1½ valve Carbon steel [2] 4 Spring - 4 valve Carbon steel - cadmium plated 5 Spindle assembly - 1½ valve Steel - glyptol coated 6 Lock nut Monel 7 Disc guide - 1½ valve Inconel 600 Disc guide - 4 valve Cast steel - glyptol coated Casing - 1½ valve 4 stainless steel pipe, sch. 40 8 Casing - 4 valve 6 seamless steel pipe, sch. 40 9 Spring washer (bottom) Steel - cadmium plated Disc bushing 10 (Assembled to disc ii) Stainless steel 11 Disc Monel [3] 12 Cotter pin - 1½ valve 18-8 stainless steel 13 Disc insert - 1½ valve Monel [3] Adjusting ring - 1½ valve Malleable iron - glyptol coated 14 Adjusting ring - 4 valve Monel [3] 15 Lock pin Monel 3 27 4 5 6 7 8 9 10 11 13 Seal 14 15 16 31 12 16 Nozzle K-Monel [3] 17 Nozzle gasket Garlock 3510 18 Base gasket 3% antimony lead 19 Breaking pin assembly gasket 1½ valve Garlock 3510 4 valve 3% antimony lead 20 Base Steel - glyptol coated 21 Lockscrew Steel 27 Spring washer (top) Steel - cadmium plated 31 Spindle assembly - 4 valve Steel with stainless steel ball 32 Cap gaskets Garlock 7022 17 18 22 23 24 20 21 26 28 19 Breaking pin assembly 22 Yoke Steel Breaking pin - 1½ valve [4][5] Bronze 23 Breaking pin - 4 valve [4] Bronze 24 Plunger assembly - 1½ valve Type 304 stainless steel Plunger assembly - 4 valve Steel 29 30 25 25 Spanner nut Monel [3] 26 Clip Hardened steel (piano wire) Housing - 1½ valve Inconel 600 28 Housing - 4 valve Steel 29 Follower Monel [3] 30 Diaphragm (lower) 3% antimony lead 33 Vacuum grill - 4 valve Monel Notes 1. For general service applications, the upper diaphragm is PTFE FEP. If other than 3% antimony lead is specified, two cap gaskets (32) are used to complete the seal. 2. The carbon steel spring (4) for 1½ chlorine service valves is colored red for 225 psi setting and colored yellow for 375 psi setting. For general service spring material is carbon steel - cadmium plated. 3. Optional materials available for fluids other than chlorine. 4. Aluminum for pressures under 100 psig. 5. The breaking pin (23) for 1½ chlorine service valves is colored blue for 225 setting and colored green for 375 psi setting. 6. Not shown (used to protect lower diaphragm (30) against vacuum damage. 4

Air capacities (valve with breaking pin mechanism - SCFM) 1½ JQU-1 and JQU-2, 10% accumulation Set pressure Air capacity psig SCFM 30 440 40 541 60 744 80 946 100 1150 120 1352 140 1555 160 1758 180 1960 200 2164 220 2367 240 2570 260 2772 280 2975 300 3178 320 3381 340 3584 360 3787 375 3939 4 JQU, 10% accumulation Set pressure psig Air capacity SCFM 50 2773 100 4991 150 7154 200 9345 250 11508 300 13727 375 17025 Notes 1. Contact your sales representative for capacities of valve alone or valve with rupture disc. 2. Temperature range: 20 F to 250 F. 3. ASME Section VIII breaking pressure tolerances are: 30-150 psi: ± 5 psi 151-275 psi: ± 10 psi 276-376 psi: ± 15 psi 4. For inlet temperatures other than 60 F, multiply above capacities by correction factor Kt. For gases of specific gravity other than 1.0 (air = 1), multiply above capacities by correction factor Ksg (see page 6). 5

Specific gravity correction factor K sg Correction factor - Ksg 2.5 2.0 1.5 1.0 0.5 0.25 0.50 0.75 1.00 1.25 1.50 1.75 Specific gravity where S = specific gravity Temperature correction factor - K t Degrees Fahrenheit K t -20 1.087-10 1.075 0 1.063 10 1.052 20 1.041 30 1.031 40 1.020 50 1.010 60 1.000 70 0.9905 80 0.9813 90 0.9723 100 0.9636 110 0.9552 120 0.9469 130 0.9388 140 0.9310 150 0.9233 160 0.9158 170 0.9085 180 0.9014 190 0.8944 200 0.8876 210 0.8811 220 0.8746 230 0.8682 240 0.8619 250 0.8558 6

Dimensions and weights G G F F E B D A C Dia. dia. E A B D C Dia. dia. 1½ valve 4 valve Dimensions and Weights Size (inches) Style A B C D E F G No. bolts Size bolt holes dia. Approximate net weight (lb) 1½ JQ 1.505 2.245 6¼ 8 2 5 /32 12¾ 4⅞ 4 - ⅞ 35 4 JQ 5 3 /16 6 3 /16 7⅞ 9½ 2 3 /16 17¾ 7¼ 8 - ⅞ 95 Maintenance instructions Chlorine Institute, Inc. Pamphlet 39 (1½ ) Chlorine Institute, Inc. Pamphlet 41 (4 ) Each pamphlet contains maintenance procedures as well as a listing of tools and test equipment. Optional pressure gauge assembly 7

2017 Emerson. All rights reserved. 8