REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

Similar documents
The High Power Stack Horizon

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

CD3000S-1PH Thyristor Unit Analog Input version

CD3000S-1PH Thyristor Unit Heater Break version

Revo SSR Solid State Relay with IFH option

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

SINGLE AND THREE PHASE THYRISTOR UNITS

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

RVS-AX Instruction Manual

Power Switching Principles

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Solid State Relays, 3-phase

celpac Solid State Relays & Contactors SAL/SAM Accessories for celpac A large range of heatsinks The 22,5mm pitch SSR solution!

Power Switching Devices

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Heat Tracing Sales Mt. Airy, Maryland Controls

1 Phase electronic contactor (SC 1)

Power Switching Devices

Contactors and Motor Starters. Smoother running. Longer lasting. Electronic contactors and motor controllers. Product overview and selection guide

Description 1/8-7.5HP


SECTION MOTOR CONTROL

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Dimensions WxHxD [mm] Weight [kg]

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

SOLID-STATE CONTACTORS

Solid State Relays contactor with Integrated Fuse Type RGC1F

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

1SVC F SVC F 0607 R100.20/30 R100.45

Flight Systems. Replacement for KASSEC DESCRIPTION

SOLSTART Instruction Manual

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Designed for ease of integration with automation systems

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DIN EN UL 508 / CSA 3RF A A 0 2

Temperature Controllers

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

ASYN205B Central Synchronizing Controller

Aldi V4 & V V1.1 5/23/2014

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

Emotron DCM Control Unit

MAQ Series Electric Actuator

Technical Data Sheets

Heavy-Duty Battery and Electrical System Diagnostic Tester

Technical Data Sheets

General Description and Quick Selection Guide...E2. Series SAS Panel Mount Hockey Puck Relays...E4. Series SAR DIN-Rail Mount Relays...

Thyristor power units TC3000. Three-phase load control. User Manual

THREE PHASE DC DRIVES

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

YASKAWA IP54 Solutions. Product Launch Information , C. Schreiter

Industrial Chargers and

Start-up instructions

All In one uninterruptible power supply solutions

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

Temperature Controllers

LR Resistance Heater Units

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

SIRIUS 3RU2 Thermal Overload Relays

UMBW-UL489 and UL1077 Listed

AUE-AUD-AU2E AU2D-AUED

HERZ Motorised Actuator

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Digital Positioner 8049

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

J TS 7090 Thyristor power switch

Technical Data Sheets

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Controls SSR2. Description

SECTION 3. PARTS INFORMATION INTRODUCTION This section identifies and lists the replaceable parts of the Henny Penny merchandiser.

Digital Positioner 8049

Design Guide. VLT Soft Start Controller MCD 100

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

ADVANCED MODULAR POWER CONTROLLER

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Inverter scroll compressors VZH single and manifold

ABB Softstarter Benefits Charnchanok Thongprad

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Application example of a motor controlled by MCD100 and protected by a circuit breaker

INDUSTRIAL POWER SUPPLIES SFL-SERIES

110 Years Expertise DC Motors AC Motors Digital Drives MOTOR CONTROL TECHNOLOGY PRODUCT CATALOGUE THREE PHASE DRIVES: TT/X RANGE

Solid state relays. and most cost-effective on the. that requires high frequency, in general manufacturing. noiseless switching. Type and size?

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

8000 Series Liquid Flow Meters

Transcription:

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution General description REVO is a compact family of solid state switches designed to replace contactors. Single phase thyristor units up to 40A. Integrated Fuse holder to save spaces inside cabinet and wiring cost available as an option. Applicable for resistive loads and infrared lamp*. REVO S 1PH and SSR series: Zero crossing firing available with logic input signal (SSR). Constant current drain with SSR input. REVO A 1PH serie: analog input 4 20mA or 0 10V with Burst firing 4, 8 or 16 cycle at 50% power requested. Internal current transformer is available as an option. Internal current transformer + Heater Break alarm (HB) to diagnostic partial or total load failure and short circuit on Thyristor, is available as an option. Side by side mounting. IP20 protection. U Comply with EMC.specification and C L US Technical specification Voltage power supply 24V min., 480V max. and 600V on request. Input signal REVO SSR and REVO S1PH: SSR (OFF state <1Vdc, ON = 4 30 Vdc). 20 ma constant current drain. REVO A 1PH: Analogue input 4 20mA and 0 10V. Firing REVO SSR and REVO S1PH: Zero Crossing ZC with SSR input; REVO A 1PH: Burst Firing 4/8/16 with 4 20mA or 0 10V and 12-24V aux. power supply. Auxiliary voltage supply REVO SSR and REVO S1PH: 12-24VAC/DC are necessary only with HB option. REVO A 1PH: 12-24V AC/DC are requested. Heater break alarm Mounting Discrimination better than 20%. Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. Latching alarm plus reset. Relay output 1A at 230V. Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button. Din rail mounting up to 40A included for all the models with heatsink (REVO S/A 1PH), for other type of mounting see the option; IP20 protection. Temperature Operating Temperature for units with heatsink REVO S 1PH and REVO A 1PH 0 40 C up to 40 A included, for higher temperature see the derating curve. Current/Temperature ratio for units supplied without heatsink. REVO SSR The nominal current depend by the heatsink choosed and by the ambient temperature. See tab 062, 070 and 090

OPTION AND DETAILS: INTEGRATED FUSE AND FUSE HOLDER Save 50% of the internal spaces inside the cabinet. Save the spaces lost over the unit due to the fuse holder and will let you save the wiring of one cable from the fuse holder to the unit. HEATER BREAK ALARM OPTION (HB) Microprocessor based. Self learning of current set, via external command or push button on front unit. Load failure with alarm latch. Thyristor short circuit diagnostic. Alarm reset function and possibility to auto reset the alarm if the normal working condition is restored. Alarm output with free voltage contact. Available from up to 40 A incl. Full insulation between SSR output coming from controller/multi loop and power supply, no common zero in our unit. Easy and fast substitution /calibration of the unit (also not expert people can do it easy. 12-24 Vac-dc Auxiliary Power Supply is requested with HB option. Available with SSR input (REVO SSR and REVO S 1PH), 0 10V & 4 20mA analog input (REVO A 1PH). INTERNAL CURRENT TRANSFORMER (ICT) Internal current transformer with Heater Break Up to 40A the current transformer is placed inside the unit as a standard. This features can save wiring cost and spaces inside the cabinet. ICT OPTION ONLY Up to the 40A the current transformer can be placed inside the unit for an external current detection, Ex: From a discrete temperature controller with current monitoring or Heater Break. The internal current transformer is sized depending by the nominal current chosen. For the units without heat sink, specify the target nominal current desired on the notes. ANALOG INPUT REVO A - ANALOG INPUT OPTION and BURST FIRING It is available up to 40 A with Burst firing on REVO A 1PH. Possibility to chose between 4 20mA or 0 10V input. Burst Firing is selectable with link jumper between BF04 08 16 cycles on at 50% power demand. Heater break alarm is available as an option. This unit must be used for 1PH loads only. 12-24 Vac-dc Auxiliary Power Supply is Requested. FLAT Cable system is available as an option to connect 12-24 Vac-dc Auxiliary Power Supply is available to save wirings time. BURST FIRING This firing performed in digital mode in our unit gives a lot of advantage because switch thyristor faster than normal ZC and at the same time without EMC interferences. Analogue input is necessary for BF and can be decided how many complete cycles We wont at 50% of power demand. On REVO A with analog input option, this value can be 04, 08 or 16. To have a better resolution you must choose REVO M 1PH series, where the BF value can be implemented from 1 to 255 complete cycles doing the firing less or more fast. When 1 is selected the firing name becomes Single Cycle.

REVO WITH FLAT CABLE CONNECTION Reduce the wiring cost with the flat cable system: The Flat cable connection option on REVO S and Revo A series will let you save wiring when HB or Analog input options are used. The cable connections of the auxiliary voltage supply and all the HB Alarm are already wired. For this features it s necessary to have N 1 REVO TU every 10 REVO with flat wiring option. REVO S WITH SAFETY RELAY (soon available) Hot N Thyristo r unit Fuse + Fuse Rel The safety relay is an extra protection that can brake the circuit in case of thyristor short circuit or in other case of alarm coming from a controller. If is supplied with fuse holder in a combination like the ones on the right, the circuit can let you remove a broken resistance with more safety. Infact breaking the circuit in two point no poles receeve voltage. REVO SSR + CUSTOM HEATSINK (soon available) CD Automation offer different kind of heatsink where is possible to mount all the REVO SSR or SAR series sold without the heatsink. (soon available )

REVO SSR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 REVO S S R _ - 0-1 MAX. Current Rathing 62 A See the tab 062 to calculate current 6 2 74 A See the tab 074 to calculate current 7 4 90 A See the tab 090 to calculate current 9 0 Nominal current range for IFH option. None (is not necessary, no IFH opt.) 0-0-25A 1-25-35A 2-35-45A 3 - Max. Voltage 480 V - 4 600 V - 6 Aux. Voltage Supply No Auxiliary Voltage 0 12-24V ac dc used with HB option 4 Input SSR S Firing ZC Zero Crossing Z Feed Back Options No Fuse 0 IFH F IFH + CT Y IFH + CT + HB H IFH + CT + HB + Flat wiring Sys. X cul us Approval 0 cul us (soon available) 0 L Manual - Italian 1 - English 2 - Version Version 1 1 IFH = Integrated Fuse + Fuse Holder CT = Current Transformer HB = Heater Break

TAB 062 TAB 074 TAB 090

REVO S 1PH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 REVO- S -1PH R S 1 _ - 0 1 Current Rathing 30 A 0 3 0-35 A 0 3 5-40 A 0 4 0 - MAX VOLTAGE 480 V - 4 600 V - 6 Aux. Voltage Supply NO 0 12-24V ac dc used with HB 4 Input SSR S Firing ZC Zero Crossing Z Feed Back Options No Fuse 0 IFH F IFH + CT Y IFH + CT + HB H IFH + CT + HB + Flat wiring Sys. X cul us Approval 0 cul us (soon available) 0 L Manual Italian 1 English 2 Version Version 1 1 IFH = Integrated Fuse + Fuse Holder CT = Current Transformer HB = Heater Break

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 REVO- A -1PH R A 1 _ - 0 1 Current Rathing 30 A 0 3 0-35 A 0 3 5-40 A 0 4 0 - MAX VOLTAGE 480 V - 4 600 V - 6 Aux. Voltage Supply 12-24V ac dc used with Analog or HB 4 Analog Input 0-10V dc V 4-20 ma A Firing BF Burst Firing 4 Cycles 4 BF Burst Firing 8 Cycles 8 BF Burst Firing 16 Cycles 6 Feed Back Options IFH IFH + CT IFH + CT + HB IFH + CT + HB + Flat wiring Sys. F Y H X cul us Approval 0 cul us (soon available) 0 L Manual Italian 1 English 2 Version Version 1 1 IFH = Integrated Fuse + Fuse Holder CT = Current Transformer HB = Heater Break