Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Similar documents
Flow nozzle for in-pipe installation, model FLC-FN-PIP Flow nozzle for flange assembly, model FLC-FN-FLN Venturi nozzle, model FLC-FN-VN

ORIFICE PLATE flow meters

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

Valves and manifolds

Diaphragm seal with flange connection For the pulp and paper industry Model

Datasheet Rev.1 Feb 2014 High precision flowmeter

Valve manifold for differential pressure measuring instruments 3-, 5-valve manifold Models IV30, IV31, IV50 and IV51

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Block-and-bleed valve 2-valve manifold Models IV20 and IV21

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

Thermowell with threaded flange (solid-machined) Screwed and welded design Models TW10-S, TW10-B

94D / 94F / 94M / 96M

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

Connection parts with nominal width DN 6 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

High-quality pressure sensor with mounted diaphragm seal With threaded connection, threaded design Model DSS10T

Thermowell For sanitary applications Model TW61, for orbital welding

Miniature multipoint thermocouple Model TC96-M

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Resistance thermometer Model TR10-B, for additional thermowell

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

NEUMO BioControl Model

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Datasheet December Daniel Orifice Plates and Plate Sealing Units Differential Pressure Flow Meters

Diaphragm seal with threaded connection Plastic version Model

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Thermocouples Model TC10-E, for Additional Thermowell

Connecting parts with nominal width DN 20 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Pressure Transmitters for Sanitary Applications Model SA-11

Resistance thermometer Model TR10-E, for additional thermowell

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Datasheet Rev.3 Feb 2015 Venturi tube

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Thermocouples Model TC10-B, for Additional Thermowell

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Gas-actuated thermometer Model 73, stainless steel version

Differential pressure gauge with electrical output signal Model A2G-15

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Bourdon Tube Pressure Gauges with Switch Contacts Models /160, Stainless Steel Version Models /160, Stainless Steel Safety Version

Bimetal Thermometers Process Industry Series, Model 55

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Bimetal thermometer Model 52, industrial series

Square Edged Concentric

Diaphragm seal with sterile connection For homogeniser machines Model

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Pressure switch, high adjustability of switch differential

Thermowell For sanitary applications Model TW61, for orbital welding

IntraNozzle Flow Nozzle Type: IFN

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

Measuring probe For ventilation and air-conditioning Model A2G-FM

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

Float switch For horizontal installation, miniature design Model HLS-M

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Machine glass thermometers Model 32, V-Form

Orifice plates and nozzles. Flow measurement using differential pressure

T-Bar Bonnet. Monoflanges STANDARD OPTIONS. O.S.&Y. Bonnet (firesafe) Gas Solution Bonnet. Anti-Tamper Bonnet

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Gas Actuated Thermometers Stainless Steel Series, Model 73

Mechatronic pressure measurement. Applications. Special features. Description

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Differential pressure gauge Model , copper alloy Model , stainless steel version

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

flowconme Types of Fittings Available Wall Thickness Sch 5 - Sch 160 (Sch 5s - Sch 160s) Others available upon special request

Resistance thermometer with digital indicator Model TR75, battery operation

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Reed sensor For bypass level indicators Model BLR

Portable pressure calibrator, Wally Box III Model CPH7600

Bimetal thermometer Model 52, industrial series

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Hot Runner Thermocouples Model TC46

Hydraulic comparison test pump Model CPP1200-X

Thermowell For sanitary applications Model TW22

Differential pressure switch Model DPS40

IFOA Integral Flow Orifice Assembly

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Pressure balance Differential pressure version Model CPB5600DP

Thermocouple Model TC10-E, for additional thermowell

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

Compact differential pressure switch Models DC, DCC

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

PRODUCT NEWS CAT.NO.-70 KPC CORPORATION FLOW CONTROL DIVISION

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

STANDARDS and SPECIFICATIONS

Transcription:

Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment and distribution Gas processing and transmission Chemical and petrochemical industry Special features Orifice plate, model FLC-OP Maximum operating temperature up to 800 C Maximum operating pressure up to 400 bar Suitable for liquid, gas and steam flow measurement Accuracy ±0.5 % of actual flow rate Repeatability of measurement of 0.1 % Orifice flange, model FLC-FL Differential pressure flow meters are used in many industrial applications. As primary flow elements, orifice plates represent the most common solution. This instrument is notable for its easy installation and management. The differential pressure generated by the primary flow element is normally transformed into an electrical signal proportional to the flow rate by a differential pressure transmitter. Annular chamber, model FLC-AC Page 1 of 10

Orifice plates, model FLC-OP Orifice plates are the simplest type of primary flow elements. Their bore diameter is calculated to generate the specified differential pressure at full scale flow rate. Suitable orifice plates are available for a wide range of different media. Materials Stainless steel (standard) Hastelloy C276 Monel 400 Duplex Super Duplex Others on request Fig. right: Fig. left: Eccentric orifice plate Quarter circle orifice plate Overview Media Square edge orifice plate Quarter circle or conical entrance orifice plate Eccentric orifice plate Segmental orifice plate Gas clean ++ - + + dirty - - ++ ++ Liquid clean ++ ++ + + viscous - ++ - - dirty + + ++ ++ corrosive + + + + Steam + + + - ++ preferred + suitable - not suitable Page 2 of 10

Square edge orifice plate This design is intended for general applications in clean media and gases. Design: per ISO 5167-2/ ASME MFC3M Nominal size: 1½" (40 mm) Nominal pressure rating: as per customer requirements β-ratio: 0.20... 0.75 Accuracy: ±0.5 % of full scale flow rate Repeatability: 0.1 % of flow rate Quarter circle and conical entrance orifice plate They are the best choice for the measurement of liquids with a low Reynolds number. Design: per ISO/TR 15377 Nominal size: 1½" (40 mm) Nominal pressure rating: as per customer requirements β-ratio: 0.100... 0.316 (conical entrance) 0.245... 0.600 (quarter circle) Accuracy: ±2 % of full scale flow rate Repeatability: 0.1 % of flow rate Eccentric orifice plate For measurements with two-phase, dirty and particle-laden media. However, for small pipe diameters an eccentric orifice plate is a better solution than a segmental orifice plate. Design: per ISO/TR 15377 Nominal size: > 4" (100 mm) Nominal pressure rating: as per customer requirements β-ratio: 0.46... 0.84 Accuracy: ±2 % of full scale flow rate Repeatability: 0.1 % of flow rate Segmental orifice plate For measurements with two-phase, dirty and particle-laden media. Design: per ASME MFC Nominal size: 4" (100 mm) Nominal pressure rating: as per customer requirements β-ratio: 0.35... 0.80 Accuracy: ±2 % of full scale flow rate Repeatability: 0.1 % of flow rate Page 3 of 10

Sealing face for flanges with raised face Raised face is the most common sealing and can be used under uncritical pressure and temperature conditions. Surface finishing 125... 250 AARH The ANSI accredited ASME standard B 16.5 requires that the flange face and the sealing face of the orifice plate have a specified roughness to ensure the compatibility of the surface with the gasket and a high quality seal. Sealing face for raised face Ring joint gasket (option) This solution is used under high temperature and pressure conditions Designs Octagonal Oval Surface finishing and ring dimensions The ring joint gasket can be manufactured in accordance with all relevant standards to suit the following flange standards: API 6A ASME/ANSI B16.5 MSS SP44 (ASME B16.47 series A) BS 1560 Ring joint The surface finishing of the ring joint gasket (< 63 AARH) complies with these flange standards. Drain or vent hole (option) Depending on the medium a drain or vent hole may be required. The hole is manufactured in accordance with ISA RP 3.2, unless otherwise specified. Drain or vent hole Page 4 of 10

Dimensions of orifice plates for flanges with raised face Thickness of the orifice plate Dimensions of the handle Nominal size [D] Plate thickness (standard) [t] Nominal size [D] A B ½... 6" 3 mm 8... 16" 6 mm 18... 26" 10 mm > 26" 16 mm ½... 5" 30 mm 120 mm 6... 12" 40 mm 150 mm 14... 18" 40 mm 180 mm > 18" 50 mm 200 mm The listed values are suitable for a differential pressure of max. 1,000 mbar. A 35 12 B Sealing face GV = Vent hole GD = Drain hole Page 5 of 10

Dimensions of orifice plates with ring joint gasket Thickness of the orifice plate Dimensions of the handle Nominal size [D] Plate thickness (standard) [t] Nominal size [D] A B ½... 6" 3 mm 8... 16" 6 mm 18... 26" 10 mm > 26" 16 mm The listed values are suitable for a differential pressure of max. 1,000 mbar. 4... 10" 40 mm 150 mm 12... 16" 40 mm 180 mm > 16" 50 mm 200 mm The listed values apply to orifice plates with a diameter of > 4". Dimensions for a diameter of < 3", see drawing below. Diameter < 3" Diameter < 3" 30 35 12 120 Diameter > 4" Diameter > 4" A 35 12 B GV = Vent hole GD = Drain hole Page 6 of 10

Orifice flanges, model FLC-FL Orifice flanges are intended for use instead of standard pipe flanges when an orifice plate or flow nozzle must be installed. Pairs of pressure tappings are machined into the orifice flanges, making separate orifice carriers or tappings in the pipe wall unnecessary. The assembly of the orifice plate is completed with jacking screws to ensure an easy removal. Nominal size Available in accordance with all relevant standards. Nominal pressure rating Available in accordance with all relevant standards. Pipe schedule The pipe schedule must be specified by the customer. Orifice flange with orifice plate Materials Carbon steel, ASTM A105 Low temperature carbon steel, ASTM A350 LF2 ASTM A182 F316 ASTM A182 F304 ASTM A182 F11 ASTM A182 F22 Others on request Pressure tappings Two ½ NPT threads are provided in each flange as standard (one with a plug). Other amount and types of threads on request. Flange tap Corner tap Sealing faces Raised face Ring joint gasket Page 7 of 10

Dimensions and weight Standard dimensions per ASME B16.36 DN Class 300 Class 600 Class 900 Class 1,500 Weight L E_D Weight L E_D Weight L E_D Weight L E_D kg mm mm kg mm mm kg mm mm kg mm mm 1" 9 171 124 9 171 124 13 171 149 13 171 149 1 ½" 13 178 155 13 178 155 18 184 178 18 184 178 2" 14 178 165 14 178 165 29 209 216 29 209 216 2 ½" 18 184 191 18 284 191 41 215 244 41 215 244 3" 21 184 210 21 184 210 34 209 241 58 241 267 4" 31 190 245 41 209 273 59 235 292 82 254 311 6" 50 206 318 82 241 356 120 285 381 186 349 394 8" 73 232 381 124 276 419 204 333 470 306 435 483 10" 100 244 445 208 314 508 291 377 546 500 517 584 12" 151 269 521 250 320 559 405 409 610 746 574 673 14" 207 294 584-339 603-434 641-606 749 16" 275 301 648-365 686-441 705-631 826 18" 341 327 711-377 743-466 787-663 914 20" 408 333 775-390 813-504 857-720 984 24 604 345 914-415 940-593 1.041-822 1.168 Values approx weight (kg) and dimensions (mm) for the assembly assuming a gasket with a thickness of 1.5 mm and a plate thickness in accordance with our standard (see page 5 + 6). Example: Flange with raised face and flange tapping Page 8 of 10

Annular chambers, model FLC-AC Annular chambers are used to achieve stable measurements under difficult process conditions. They are mounted between already installed process flanges. The different pressures in the pipe are compensated for by using an annular gap located between the interior of the pipe and the annular chamber. Nominal size Available in accordance with all relevant standards Nominal pressure rating Available in accordance with all relevant standards Pipe schedule The pipe schedule must be specified by the customer. Annular chambers Materials Annular chambers can be delivered in a wide range of materials. Material of the orifice plate: Stainless steel 316/316L, other materials on request. Pressure tappings Two ½ NPT threads are provided in each carrier ring as standard (one with a plug). Other amount and type of threads on request. Sealing face The sealing face must be specified by the customer. Dimensions The dimension of the annular chamber corresponds to the standard used for the process flange. Page 9 of 10

Ordering information Orifice plate (model FLC-OP) Nominal size / Nominal pressure rating / Version / Sealing face / Drain or vent hole / Material Orifice flange (FLC-FL) Nominal size / Nominal pressure rating / Pipe schedule / Sealing face / Pressure tappings / Material Annular chamber (model FLC-AC) Nominal size / Nominal pressure rating / Pipe schedule / Sealing face / Pressure tappings / Material 2013 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 10 of 10 06/2013 GB WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. (+49) 9372/132-0 Fax (+49) 9372/132-406 E-mail info@wika.de www.wika.de