BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Similar documents
R-Rated medium voltage fuses for motor circuit protection

PT Medium voltage fuses for potential and small power transformers

R-Rated medium voltage fuses for motor circuit protection

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Industry s most comprehensive medium voltage circuit protection

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Electric vehicle auxiliary fuses 500 Vdc, A

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

6.3 mm reverse quick connect

up to 30A limited by conductor size Operating and storage temperature:

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

BH-1 modular fuse blocks, 700 V, 400 A

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Low-Peak 600V Class RK1

Effective December 2015 Supersedes September 2013

Bussmann series Quik-Spec Power Module Switch elevator disconnect

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

Class J modular ferrule and knifeblade fuse blocks

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

UL Recognized power distribution blocks

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

Medium Voltage Fuses. Industry s most comprehensive medium voltage circuit protection

E-RATED/MEDIUM VOLTAGE FUSES

RBA Catalog Numbers and Information

N0N A 250V One-Time Class H Fuse

Quik-Spec Coordination Panelboard A fusible panelboards

Compact Circuit Protector

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Quik-Spec Coordination Panelboard A fusible panelboards

Design Tests for the 38.0 kv ELSP Current-limiting Fuse per ANSI/IEEE C

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

X-Limiter full-range current-limiting fuse

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

K-Limiter high ampere Companion II fuse

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Direct-connected capacitor fuse

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Compact Circuit Protector (CCP)

WLI Medium Voltage Switchgear Renewal Parts

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

2.7. Expulsion Fuses. Contents. RBA/RDB Type Fuses (Including Superseded BA Fuses) RBA/RDB Type Fuses (Including Superseded BA Fuses)

ELF -LR current-limiting fuse

Edison modular fuse, vault application products

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Bussmann. Circuit Protection Solutions

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Medium Voltage Fuses

High Speed Fuses. Section Contents Page

Bussmann series IEC cylindrical fuses

CMU medium voltage power fuses

The easiest and fastest way to select and specify the right control circuit fuse

IEC Standard Back-Up Fuse-Links

Medium Voltage. Section Contents. Page. Introduction...100

Low Voltage Fuses AFaC and BaC types

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

www. ElectricalPartManuals. com

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

600 A 15 kv class T-OP II deadbreak connector

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Product Selection Guide

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

NX indoor current-limiting fuses

The easiest and fastest way to select and specify the right fuse

Specification made simple for selective coordination in a compact size

600 A 35 kv class BT-TAP deadbreak connector

Figure 1. ELSG Current-Limiting fuses. TABLE 1 Maximum Interrupting Current (rms symmetrical) INSTALLATION

A. Submit manufacturer's literature and technical data before starting work.

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

D-73P disconnect and bypass switches

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

600 A 25 kv class BT-TAP deadbreak connector

Edison single-phase capacitor switch

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

S505SC 5 x 20 mm Time-delay, axial lead ceramic tube fuses

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

600 A 15 kv class Cleer loadbreak connector system

3.2. Current Limiting Fuses. Contents

600 A 28 kv class Cleer loadbreak connector system

Medium voltage fuses Medium voltage fuses

A 1.2 kv class externally removable secondary bushing

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

PROTECTION AND CONTROL

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

M-Force three-phase switch

Transcription:

8.3kV E-Rated Description: E-Rated, current-limiting, medium voltage fuses for feeder circuit, switchgear and transformer protection. Supersedes pril 2015 USSMNN SERIES Medium voltage fuses for feeder circuit, switchgear and transformer protection Features and benefits: urrent-limiting E-Rated medium voltage fuses are defined by their melting time-current characteristic that permit their electrical interchangeability with other fuses of the same E Rating. E-Rated fuses must have a defined current response time specified by NSI 37.46. E-Rated fuse of 100 amps and below must melt in 300 seconds at an RMS current within the range of 200% to 240% of the fuse s nameplate current rating. E-Rated fuses greater than 100 amps must melt in 600 seconds at an RMS current within the range of 220% to 264% of the fuse s nameplate current rating. E-Rated fuses are physically dimensioned for easy installation in existing hardware. urrent-limiting fuses provide positive interruption even on low fault currents. The fuse limits the magnitude of electromechanical stresses in the protected apparatus. onstructions available in ferrule, bolt-on and clip lock, and specialty mount fuses for MPGRD motor starters. Outdoor rating available on select catalog numbers (requires installation in a suitable enclosure). Open fuse indicator easily integrates into automation schemes and speeds troubleshooting by providing a positive visual indication of fuse operation. 50/60Hz operating frequency for worldwide application. Mountings are available in disconnect and non-disconnect versions with porcelain or glass polyester insulators. Live parts and end fittings available. Typical applications: Medium voltage transformer primary protection Medium voltage feeder circuit protection Medium voltage switches Medium voltage metal-enclosed switchgear

8.3kV E-Rated medium voltage fuses for E-Rated medium voltage ferrule fuses atalog symbols: 8LE-_E-D (10-25) 8LE-_E (10-350) 8HLE-_E (10-350) Ratings*: Volts 8.3kV mps 10 to 350 Interrupting ratings 50k RMS Sym * See catalog number tables for voltages, ampacities and interrupting ratings by catalog number. Recommended fuse holders: gency information: E-Rated fuses meet the performance characteristics of NSI 37.46 3.31 (84.1) mp rating LE 10E-D 25E-D 30E 175E Single barrel 15E 25E Single arrel 200E 350E Double barrel HLE 10E-175E Single barrel 200E 350E Double barrel Fuse mounting type* Voltage IL (kv) pproximate dimensions - in (mm) Diameter lip center Length atalog number Mounting (including live parts, end fittings)** Porcelain insulator Glass-polyester insulator Live parts (including end fittings) End fittings (disconnect only) Nondisconnect 3.0 (76) 14 (356) 17.9 (455) 75 8LE-PNM-D 8LE-GNM-D LE-NL-D Disconnect 75 8LE-PDM-D 8LE-GDM-D LE-DL-D LE-DF-D Nondisconnect 2.0 (51) 14 (356) 15.5 (394) 75 8LE-PNM- 8LE-GNM- LE-NL- Disconnect 75 8LE-PDM- 8LE-GDM- LE-DL- LE-DF- Nondisconnect 3.0 (76) 14 (356) 17.9 (455) 75 8LE-PNM-E 8LE-GNM-E LE-NL-E Disconnect 75 8LE-PDM-E 8LE-GDM-E LE-DL-E LE-DF-E Nondisconnect 3.0 (76) 12 (305) 15.9 (404) 75 8HLE-PNM-D 8HLE-GNM-D LE-NL-D Disconnect 75 8HLE-PDM-D 8HLE-GDM-D LE-DL-D LE-DF-D Nondisconnect 3.0 (76) 12 (305) 15.9 (404) 75 8HLE-PNM-E 8HLE-GNM-E LE-NL-E Disconnect 75 8HLE-PDM-E 8HLE-GDM-E LE-DL-E LE-DF-E * See page 4 for illustrations and dimensions ** End fittings supplied only when required. Recommended fuseclips: Fuse diameter - lip dimensions - in (mm) atalog Description in (mm) Figure D E F G number Enclosed fuseclip 2 (51) 1 3.75 (95) 1.98 (50) 2.01 (51) 1.19 (30) 4.54 (115) 1.51 (38) 0.4 (10) 3354710* Enclosed fuseclip 3 (76) 1 4.14 (105) 2.45 (62) 3.01 (76) 1.19 (30) 5.64 (143) 1.51 (38) 0.4 (10) 3354730* Open fuseclip 3 (76) 2 See dimensions drawing 10065 Spring loaded open 3 (76) 3 See dimensions drawing 907867G04 fuseclip *For single barrel applications only. Not sold in pairs. Figure 1 Figure 2 Figure 3 D G F E 2

8.3kV E-Rated medium voltage fuses for Technical Data 10352 LE and HLE type fuses mp rating Dimensions - in (mm) Length Diameter lip centers Interrupting rating k (RMS Sym.) Number of barrels Installation location atalog number LE Long construction (Westinghouse) 10 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-10E-D 15 15.5 (394) 2 (51) 14 (356) 50 1 Indoor 8LE-15E* 15 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-15E-D 20 15.5 (394) 2 (51) 14 (356) 50 1 Indoor 8LE-20E* 20 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-20E-D 25 15.5 (394) 2 (51) 14 (356) 50 1 Indoor 8LE-25E* 25 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-25E-D 30 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-30E 40 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-40E 50 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-50E 65 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-65E 80 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-80E 100 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-100E 125 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-125E 150 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-150E 175 17.9 (455) 3 (76) 14 (356) 50 1 Indoor/outdoor 8LE-175E 200 17.9 (455) 3 (76) 14 (356) 50 2 Indoor/outdoor 8LE-200E 250 17.9 (455) 3 (76) 14 (356) 50 2 Indoor/outdoor 8LE-250E 300 17.9 (455) 3 (76) 14 (356) 50 2 Indoor/outdoor 8LE-300E 350 17.9 (455) 3 (76) 14 (356) 50 2 Indoor/outdoor 8LE-350E HLE Short construction 10 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-10E 15 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-15E 20 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-20E 25 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-25E 30 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-30E 40 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-40E 50 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-50E 65 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-65E 80 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-80E 100 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-100E 125 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-125E 150 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-150E 175 15.9 (404) 3 (76) 12 (305) 50 1 Indoor/outdoor 8HLE-175E 200 15.9 (404) 3 (76) 12 (305) 50 2 Indoor/outdoor 8HLE-200E 250 15.9 (404) 3 (76) 12 (305) 50 2 Indoor/outdoor 8HLE-250E 300 15.9 (404) 3 (76) 12 (305) 50 2 Indoor/outdoor 8HLE-300E 350 15.9 (404) 3 (76) 12 (305) 50 2 Indoor/outdoor 8HLE-350E * Fuses conform to dimensional standards established by Westinghouse. 3

8.3kV E-Rated medium voltage fuses for LE and HLE type mountings - in (mm) atalog number Disconnect single barrel Hole centers Overall length Hole Inset Hole centers ontact height Overall height IL D E F G kv 8LE-GDM- 15.24 (387.1) 6 (152.4) 28 (711.2) 0.75 (19) 1.75 (44.4) 7 (177.8) 12.25 (311.1) 75 8LE-GDM-D 15.24 (387.1) 6 (152.4) 25 (647.7) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.22 (361.2) 75 8LE-PDM- 15.24 (387.1) 6 (152.4) 28 (711.2) 0.75 (19) 1.75 (44.4) 7 (177.8) 12.25 (311.1) 75 8LE-PDM- 15.24 (387.1) 6 (152.4) 25 (647.7) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.22 (361.2) 75 8HLE-GDM-D 16.25 (412.8) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 11.72 (297.7) 75 8HLE-PDM-D 16.25 (412.8) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 11.72 (297.7) 75 Disconnect double barrel 8LE-GDM-E 15.24 (387.1) 6 (152.4) 25 (647.7) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 17.78 (451.6) 75 8LE-PDM-E 15.24 (387.1) 6 (152.4) 25 (647.7) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 17.78 (451.6) 75 8HLE-GDM-E 16.25 (412.8) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 17.78 (451.6) 75 8HLE-PDM-E 16.25 (412.8) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 17.78 (451.6) 75 Non-disconnect single barrel 8LE-GNM- 15.25 (387.3) 6 (152.4) 24.5 (622.3) 0.75 (19) 1.75 (44.4) 7 (177.8) 9.75 (247.6) 75 8LE-PNM- 15.25 (387.3) 6 (152.4) 24.5 (622.3) 0.75 (19) 1.75 (44.4) 7 (177.8) 9.75 (247.6) 75 8LE-GNM-D 15.25 (387.3) 6 (152.4) 25 (635) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 11.29 (286.7) 75 8LE-PNM-D 15.25 (387.3) 6 (152.4) 25 (635) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 11.29 (286.7) 75 8HLE-GNM-D 16.25 (412.7) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 8.79 (223.3) 75 8HLE-PNM-D 16.25 (412.7) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 8.79 (223.3) 75 Non-disconnect double barrel 8LE-GNM-E 15.24 (387.1) 6 (152.4) 25 (635) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.98 (380.5) 75 8LE-PNM-E 15.24 (387.1) 6 (152.4) 25 (635) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.98 (380.5) 75 8HLE-GNM-E 16.25 (412.7) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.98 (380.5) 75 8HLE-PNM-E 16.25 (412.7) 6 (152.4) 23 (584.2) 0.62 (15.7) 1.75 (44.4) 7 (177.8) 14.98 (380.5) 75 LE and HLE type disconnect mounting LE and HLE type non-disconnect mounting D G F D G F E E E E D Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized. D 4

8.3kV E-Rated medium voltage fuses for Technical Data 10352 E-Rated medium voltage specialty mount fuses Dimensions for HL - in (mm) atalog symbols: 8HLE-_E (special dimension fuses for use with 7.2kV rated, 800 amp MPGRD motor starting assemblies) 8HLE-_E (bolt-on version) 8HL-_E (clip-lock version) 0.5 (12.7) Indicator* 4.31 (109.5) 0.25 (6.4) Ratings*: Volts 8.3kV 1.25 (31.8) 1.25 (31.8) mps 10 to 350 Interrupting ratings 50k RMS Sym 7.94 (201.7) * See catalog number tables for voltages, ampacities and interrupting ratings by catalog number. gency information: E-Rated fuses meet the performance characteristics of NSI 37.46 Recommended live parts for clip-lock fuses atalog number HL-NL-1 Dimensions for HLE - in (mm) 2.12 (53.8) Indicator to be located here 3.31 (84.1) 2.12 (53.8) Indicator to be 5

8.3kV E-Rated medium voltage fuses for HLE type fuses (special dimension fuses for use with 7.2kV rated, 800 amp MPGRD motor starting assemblies) mp rating Interrupting rating k (RMS Sym.) Number of barrels atalog number 10 50 1 8HLE-10E 15 50 1 8HLE-15E 20 50 1 8HLE-20E 25 50 1 8HLE-25E 30 50 1 8HLE-30E 40 50 1 8HLE-40E 50 50 1 8HLE-50E 65 50 1 8HLE-65E 80 50 1 8HLE-80E 100 50 1 8HLE-100E 125 50 1 8HLE-125E 150 50 1 8HLE-150E 175 50 1 8HLE-175E 200 50 2 8HLE-200E 250 50 2 8HLE-250E 300 50 2 8HLE-300E 350 50 2 8HLE-350E HLE bolt-on versions mp rating Dimensions - in (mm) Overall length Diameter Hole centers Interrupting rating k (RMS Sym.) Number of barrels Installation location atalog number 10 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-10E 15 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-15E 20 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-20E 25 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-25E 30 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-30E 40 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-40E 50 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-50E 65 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-65E 80 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-80E 100 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-100E 125 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-125E 150 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-150E 175 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 1 Indoor 8HLE-175E 200 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 2 Indoor 8HLE-200E 250 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 2 Indoor 8HLE-250E 300 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 2 Indoor 8HLE-300E 350 19.25 (488.9) 3 (76.2) 17.88 (454.2) 50 2 Indoor 8HLE-350E HL clip lock versions mp rating Dimensions - in (mm) Overall length Diameter Hole centers Interrupting rating k (RMS Sym.) Number of barrels Installation location atalog number 65 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-65E 80 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-80E 100 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-100E 125 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-125E 150 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-150E 175 22.5 (571.5) 3 (76.2) N/ 50 1 Indoor/outdoor 8HL-175E 200 22.5 (571.5) 3 (76.2) N/ 50 2 Indoor/outdoor 8HL-200E 250 22.5 (571.5) 3 (76.2) N/ 50 2 Indoor/outdoor 8HL-250E 300 22.5 (571.5) 3 (76.2) N/ 50 2 Indoor/outdoor 8HL-300E 350 22.5 (571.5) 3 (76.2) N/ 50 2 Indoor/outdoor 8HL-350E 6

8.3kV E-Rated medium voltage fuses for Technical Data 10352 8.3kV time-current curves minimum melt for 8LE-_E and 8LE-_-D Times in seconds urrent in amperes 8LE-_ urve 70548501 pril 16, 1999 Reference # 563532 urve 70546201 Reference # 705462 urve 70546401 Reference # 705464 7

8.3kV E-Rated medium voltage fuses for 8.3kV time-current curves total clear for 8LE-_E and 8LE-_-D Time in seconds urrent in amperes 8LE-_ urve 70548601 pril 16, 1999 Reference # 563533 urve 70546301 Reference # 705463 urve 70546501 Reference # 705465 8

8.3kV E-Rated medium voltage fuses for Technical Data 10352 8.3kV peak let-through for 8LE-_E and 8LE-_-D Peak instantaneous let-through current in Kilo-amperes 8LE-_ vailable current in amperes urve 70548801 September 1999 Reference # 705488 urve 70547301 Reference # 705473 9

8.3kV E-Rated medium voltage fuses for 8.3kV Time-current curves minimum melt for 8HLE-_E, 8HLE-_E and 8HLE-_E Time in seconds vailable current in amperes 8HLE-_, 8HLE-_, 8HLE-_ urve 70548507 pril 16, 1999 Reference # 563532 urve 70546203 Reference # 705462 urve 70546403 Reference # 705464 10

8.3kV E-Rated medium voltage fuses for Technical Data 10352 8.3kV Time-current curves total clear for 8HLE-_E, 8HLE-_E and 8HLE-_E Time in seconds 8HLE-_, 8HLE-_, 8HLE-_ vailable current in amperes urve 70548607 pril 16, 1999 Reference # 563533 urve 70546303 Reference # 705463 urve 70546503 Reference # 705465 11

8.3kV E-Rated medium voltage fuses for 8.3kV peak let-through for 8HLE-_E, 8HLE-_E and 8HLE-_E Peak instantaneous let-through current in Kilo-amperes 8HLE-_, 8HLE-_, 8HLE-_ vailable current in amperes urve 70548804 September 1999 Reference # 705488 urve 70547201 Reference # 705472 12

8.3kV E-Rated medium voltage fuses for Technical Data 10352 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. ll other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton oulevard leveland, OH 44122 United States Eaton.com ussmann Division 114 Old State Road Ellisville, MO 63021 United States 2015 Eaton ll Rights Reserved Printed in US Publication No. 10352 U-S15152 December 2015 Eaton, ussmann and MPGRD are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. For Eaton s ussmann series product information, call 1-855-287-7626 or visit: Follow us on social media to get the latest product and support information.