AIRPORT PERIMETER SECURITY

Similar documents
2017 CATALOG East Main Street Mesa, AZ

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

White Paper. How Do I Know I Can Rely on It? The Business and Technical Cases for Solar-Recharged Video Surveillance Systems

Billboard LED Solar System STOP! THIS IS IMPORTANT

Solar Electric Modules

Power where you need it.

Solar Power Energy Harvesting Electrical Integration

TECHNICAL WHITE PAPER

Research Challenges for Automated Vehicles

T H E S M A R T B E N C H

Automotive Electronics/Connectivity/IoT/Smart City Track

SentryGOLD Fully-Automated Fuel Management System

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

THE SMART WAY TO PARK. wireless vehicle detection system

RB-Mel-03. SCITOS G5 Mobile Platform Complete Package

Laird Thermal Systems Application Note. Cooling Solutions for Automotive Technologies

Why Is My PV Module Rating Larger Than My Inverter Rating?

UL (9050, 9100, 9150) PG. 10 PG.

Latest Developments in Battery Connector Technology for Commercial Energy Storage Systems

Force Based Condition Monitoring of Railway Infrastructure

Videosystem CAR-READER

Back Up Essential Circuits or Your Whole House. Protect the things that matter most.

Direct Drive Rotary An Increasingly Attractive Servo Choice

596 Rectifier Retrofit

LED Power Systems. As retailers and brands enhance their in-store. for Retailers and Brands

HOW TO MAKE YOUR OWN BATTERIES

The Solar Power Kit includes the following components. Please be sure you have all listed components before beginning. 5/16" x 2" Carriage Bolt

VERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED

Environmental benefits. Lamp disposal problems are eliminated due to the long life of LED lights, and no resources are used in routine maintenance.

Designing Stand Alone Systems. Overview, components and function, Elements in Design

flow measurement solutions RIM10 series rotor insertion flowmeters

ZF Advances Key Technologies for Automated Driving

Minimizing Transmix With FuellCheck

Autonomous Vehicle Implementation Predictions Implications for Transport Planning

1/7. The series hybrid permits the internal combustion engine to operate at optimal speed for any given power requirement.

Multilink Transportation Power Solutions

DO COMMERCIAL BUILDINGS HAVE POWER PROBLEMS? THE ANSWER IS - THEY CERTAINLY DO.

TriPac Evolution. The industry-leading APU that delivers lower operating costs and superior driver comfort.

UNIVERSITÉ DE MONCTON FACULTÉ D INGÉNIERIE. Moncton, NB, Canada PROJECT BREAKPOINT 2015 IGVC DESIGN REPORT UNIVERSITÉ DE MONCTON ENGINEERING FACULTY

SUBJECT AREA(S): Amperage, Voltage, Electricity, Power, Energy Storage, Battery Charging

ADASE 2. Road to Vehicle Communications via DSRC : the AIDA system

Automatic Gate Openers Gate Opener Accessories

Virginia Tech Research Center Arlington, Virginia, USA. PPT slides will be available at

Quick Check Drive Touchless Alignment Inspection

Temperature sensors: Make the right choice, RTD vs. TC

MMATERIALS. Vacuum M 01. Magnetrons... M 02. MATERIALS / Inorganics & thin films guide

How to Degauss Car Tires

Overview. Battery Monitoring

Eurathlon Scenario Application Paper (SAP) Review Sheet

5067 Mini BDFB / BDCBB

Hydraulic Railcar Maintenance Equipment

Cochran Undersea Technology

Running the Electric Power Grid

Lunar Architecture and LRO

Chrysler Portal Concept ENGINEERING

DIFFERENTIAL PRESSURE BATTERY CHARGERS

MORNINGSTAR PRODUCT TRAINING

EVlink Parking charging stations. Simpler for drivers. Smarter for your city.

PIG PASSAGE INDICATORS

ABB life cycle services Uninterruptible power supplies

HYBRID POWER FOR TELECOM SITES

Compact Solar School Zone Flashers The Next Generation

31 SERIES Modular area fixtures. Replaces: 1000W HID

The Advancement of Automotive Connectivity: How the Expansion in Bandwidth Paves the Way for Autonomous Driving

LOBO. Dynamic parking guidance system

Extract from the 4 Corners program transcript from Jonathan Holmes' report into energy efficiency in Australian households, "The Home Front".

The Evolution of Vertical Wind Technology

Automated Vehicle Anti-Theft Security System

50mW Blue Forklift Warning Laser - Blue Pedestrian Safety Laser - Projects Blue Line on Floor - IP54

Dankoff LCB Solar Pump & Fan Controller. INSTRUCTIONS For INSTALLATION and OPERATION

Network Powering Strategies and Alternatives

Smart Cities Transformed Using Semtech s LoRa Technology

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

The Energy Detective

Intelligent Transportation Systems. Secure solutions for smart roads and connected highways. Brochure Intelligent Transportation Systems

Solar Powered Wireless Sensors & Instrumentation

TED 5000 USER MANUAL

100W Basic Kit (GS-100-Basic)

How Do I Ship a Lithium Battery? Start with these four questions to simplify your compliance responsibilities.

HYBRID AIRFIELD GROUND LIGHTING REAL ALTERNATIVE FOR CONVENTIONAL AGL

INTRODUCTION Team Composition Electrical System

ASTM D4169 Truck Profile Update Rationale Revision Date: September 22, 2016

INSTRUCTIONS. #82028 Diesel Nitrous System. Thank you for choosing ZEX products; we are proud to be your manufacturer of choice.

LOXAHATCHEE ELECTRONICS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Field Application of Fuel Cells Increasing Energy Security. Jon Rice, Ultra Electronics

INTRONICS CORPORATE PROFILE

BLADEcontrol Greater output less risk

How Off Grid Solar Works

Power Grid & Blackouts. Prof. Ramzy R. Obaid

EPSRC-JLR Workshop 9th December 2014 TOWARDS AUTONOMY SMART AND CONNECTED CONTROL

The Latest Sensor Trends

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

DTI Guardian Safety System with TM. Intel-a-Valve Technology EMERGENCY ENGINE SHUTDOWN SYSTEM

Transforming Transforming Advanced transformer control and monitoring with TEC

Virginia Tech Research Center Arlington, Virginia, USA

Range. Alcad Single Cell Range. Powerful assurance for maximum operating reliability

Beamtower Infrared barrier for large outdoor areas

INTELLIGENT STREETLIGHTS A Platform for Smart Cities

INDUCTROL. Voltage Regulator CPO 97.09F. updated 03/09

Transcription:

AIRPORT PERIMETER SECURITY Fiber SenSys

WHITE PAPER BY Duwayne Anderson Duwayne Anderson is Chief Technologist at Fiber SenSys and has over 20 years experience in the area of fiber optics. Mr. Anderson spent 15 years as a Principal Engineer at Tektronix where he was responsible for the definition and design of fiber-optic test equipment. He was also the Principal Engineer at Phoseon where he designed high-power solid state UV systems. His other industry experience includes several years each at Honeywell and Goodyear Aerospace. Mr. Anderson has 28 patents and is the principal author of a text book on trouble shooting fiber-optic networks. Page 2 of 9

INTRODUCTION In recent years security at America s airports has focused on such things as access control, dangerous cargo, screening, and other measures associated with activities near the airport terminal. Today there s a broader aspect of airport security that s gaining increased recognition; the perimeter around the airfield as well as airport buildings and other assets. To meet this challenge Fiber SenSys offers a perimeter-security product designed specifically with airports in mind. The Airport Defender TM uses distributed point-locating optical fibers to sense minute vibrations caused by intruders trying to climb over, cut through, or dig under the perimeter fence. Software under the brand name AutoTune TM allows the user to teach the system through a process of simulating various sources of nuisance alarms and real intrusions. AutoTune TM uses powerful search algorithms and simulations to rapidly test and evaluate how the system would perform when tuned using hundreds of different possible parametric configurations, and then it picks the best configuration; the configuration that optimizes both probability of detection (PD) and nuisance alarm rate (NAR). This sophisticated software automatically learns to distinguish the differences between vibrations caused by wind, traffic, and heavy equipment and those caused by intruders, giving Airport Defender industry-leading PD and ultra-low NAR. The all-fiber sensor is immune to electromagnetic interference from airport radar, as well as lightning strikes, and requires no maintenance over the 20-year expected lifetime of the product. Airport Defender is designed to be the easiest and most effective perimeter system for airports and other critical infrastructure. With on-site solar power generation and a wireless mesh network, Airport Defender eliminates the cost and labor of installing power and network infrastructure at the perimeter. By eliminating the overhead costs and complexity associated with infrastructure, Airport Defender saves hundreds of thousands of dollars and improves installation schedules by weeks or even months. DISCUSSION Airport perimeters are large, often tens of kilometers long, and they frequently traverse varying environments, from areas along wooded or grassy regions to parts that are heavily encumbered by buildings, equipment, sidewalks, roads, and other infrastructure. These conditions often make it difficult to put perimeter security sensors around the entire perimeter, and very expensive to place localized security sensors around portions of the perimeter that are far from electrical and communications infrastructure. Fiber SenSys provides an elegant solution to these problems with the Airport Defender 525 (AD-525). This state-of-the-art sensor uses fiber optics to detect slight vibrations of the fence Page 3 of 9

and signal the alarm processor (APU) to sound an alarm when intruders are present. But unlike other systems the AD-525 doesn t require the expense of bringing power and communications lines to the perimeter, or installing the sensor electronics in a central location and then stringing non-sensing fiber out to the perimeter. Stringing power and communications wires out to remote parts of an airport perimeter can be (and often is) more expensive than the security equipment itself. For example, installing optical fiber and electrical power in buried conduit can cost between $20 and $30 per foot. Since installers cannot simply trench straight across the airport runway (because that would shut down air traffic) the infrastructure and optical sensing cable must be put into conduit that is trenched and buried around much of the airport s perimeter. This distance can be thousands of yards, and at $20 per foot the cost to install this infrastructure can easily exceed $200,000. Airport Defender circumvents these problems by using a secure, high-speed wireless network and on-site power generation (figure 1). Fiber SenSys can offer this new product because of unparalleled electrical energy efficiency and environmental robustness in our new point-locating fiber-optic sensors. Figure 1. The APU (housing electronics and optics) senses disturbances at the perimeter, along the optical fiber. Alarms created by these disturbances are communicated wirelessly to the head end in the airport terminal. Remote electrical power (either solar or thermo-electric) powers the wireless modem and the APU. Page 4 of 9

The AD-525 electro-optics module is extremely efficient, requiring only 8 watts to monitor up to 25 zones. 1 This low power drain means the AD-525 can operate off of remote power-generating systems like solar/battery and thermo-electric (TE). The AD-525 is also environmentally robust and rated for outdoor operation. Our unique fiber-optic sensor is the key to environmental robustness. Other point-locating systems have expensive and highly sensitive lasers, which are required for some fiber-optic interferometers. The AD-525 also uses interferometry, but unlike our competitors Fiber SenSys uses speckle interferometry, which allows the sensing element to consist of just one fiber. This enables us to use simple off-the-shelf lasers that are highly robust and able to operate properly over a wide range of temperatures. The combination of low power drain and a rugged operating temperature profile means the AD 525 can be located remotely from the terminal and powered using an on-site power source such as a TE generator or solar panels. Competitors products must be located in air-conditioned environments and may draw up to 500 watts, making them far too power hungry for remote/distributed installations. Solar panels convert sunlight directly into DC electrical voltage using semiconductor materials. The solar panels are used to charge batteries that run the electronic equipment (APU and wireless modem). See figure 2. Figure 2. The solar-powered module consists of solar panels that charge batteries used to run the APU and wireless modem. A controller optimizes the charging process. The batteries are designed and sized to store enough energy to power the system during nighttime and seasonally expected periods of cloud cover. The controller manages the flow of energy between the solar panels, the battery, and the electronic equipment. When there s an excess of solar energy the controller uses some of it to 1 This works out to 0.32 watts per zone. Competitors systems require up to 500 watts for operation in addition to the energy required for environmental controls, making them impractical for operation using remote power. Page 5 of 9

recharge the battery, and when there s no solar energy (rain, nighttime, etc.) the controller uses energy in the battery to operate the electronic equipment. The solar-powered system is all solid state with no moving parts. In the northern hemisphere the solar panels are mounted in a fixed, optimum orientation facing south and tilted at 15 degrees plus the local latitude. 2 We use fixed panels to simplify the system, giving optimum reliability and greater MTBF. In most cases this also minimizes the cost. The solar-powered system is carefully designed for each site to operate year round in all types of weather. These calculations draw on data bases that specify the average available solar energy during any particular month at a particular location. These data are used to determine the required size of the solar panel and the capacity of the batteries. For a typical North American location the panels are roughly one meter square and the batteries (12 volts) are rated at 200 amp-hours. A single outdoor-rated box contains the battery, controller, APU and wireless modem. This box is mounted slightly above the ground to the same metal pole that supports the solar panels. In most parts of the United States, particularly the south and southwest, solar energy is plentiful making the solar option an obvious and economic choice. In those regions with inadequate solar power the best choice for on-site power generation is a TE generator. TE generators work on the principal that heat applied to the junction of two different semiconductors (or metals) creates a voltage across the junction (figure 3). This phenomenon has many applications and is the basis of operation for thermocouples. The effect can also be used to generate electrical power by applying a heat source to a properly designed junction. For customers in areas with inadequate solar energy, Fiber SenSys offers a commercially available TE generator. Since our APUs are so efficient and draw so little electrical power, the TE generator (rated at 20 watts) can operate the AD-525 (APU and wireless modem) more than a year using the fuel in a single buried 500-gallon tank of propane. Like the solar option, the TE generator has no moving parts and is extremely reliable. 2 For fixed panel systems designed to work year round, the solar panels are optimized for the month with the least amount of solar energy. This optimization involves tilting the panels 15 degrees toward the equator (total tilt = local latitude plus 15 degrees). Page 6 of 9

Figure 3. The TE generator uses heat,, applied to a specially designed semiconductor junction, to generate electrical current. Because the AD-525 is so efficient a single 500-gallon buried propane tank holds enough fuel to run the system for an entire year. The third critical component of the Airport Defender is the network. For Airport Defender the network requirements are simple: 1. Wireless (to avoid the cost of installing wired infrastructure) 2. Low power (to operate off remote solar or TE power systems) 3. Secure 4. Easy to use 5. Flexible architecture To meet these system requirements Fiber SenSys uses wireless modems from Fluidmesh for the Airport Defender network. 3 This is a self-healing wireless network configurable in point-to- point, point-to-multipoint, mesh, and mixed topologies. 3 Approvals: FCC CFR 47 Part 15, class B; Industry Canada RSS 210; CE Page 7 of 9

Figure 4. The wireless network can be configured in virtually any topology, making it highly versatile. Operating at 2.4 and 5 GHz, the system s high bandwidth facilitates transmission of both the alarm data from the APU as well as from optional cameras installed on the perimeter. The network is Web based and fully compatible with IP cameras and video servers and ensures security via proprietary communications protocol, VPN support and cryptography (SSL, HTTPS). Figure 5. The Fluidmesh wireless modem provides a flexible, high-speed network that can be quickly and easily set up. Page 8 of 9

SUMMARY These three components: fiber-optic sensor, remote electrical power, and a wireless network, when integrated together form a unique and powerful solution for hard-to-reach perimeters. With this integrated solution customers have an easy-to-use system solution that provides the ultimate in perimeter sensing while eliminating the need to bring communications and power wiring to the perimeter, saving hundreds of thousands of dollars in many applications. Page 9 of 9