Electrical operating instructions

Similar documents
Electrical operating instructions

Mechanical Operating Instructions

Electrical operating instructions

Electrical Operating Instructions

Mechanical operating instructions

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Electrical operating instructions

Electrical operating instructions

Electrical Operating Instructions

Operating instructions

Installation Instructions

Operating instructions

Electrical operating instructions

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Installation instructions

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

User Manual Rittal PMC UPS 6kVA

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Installation Instructions

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Installation instructions

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Battary powered cutting tool. AS6-S32 Art convincing solutions. Video

Porte 150 Users Manual Swing Gate Opener 24V DC

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating instruction and technical description

Assembly and Maintenance Manual Type ASNU

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Battery powered cutting tool. AS6ST-20 Art convincing solutions. Video

Increased requirements on external DC-breakers for transformerless PV inverters in Australia

Timing-Belt Reverse Unit 8 80 R50 II Notes on Use and Installation

Chain wheel rolling door drives DKM 170, 250, 350, 500 and 750 WKM 170

Operating instructions Solenoid interlock EX-AZM About this document. Content

M A N U A L. Field Current Controller F2.2

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Technical Manual Electrical Power Supply System T4002

OLYMPIAN MODEL 740 Operation and Service Manual

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Assembly and Maintenance Manual Type RSBW

Shaft mounted rolling door drives DFM/DFE 100, 170, 250, 350, 500 and 750 WFM/WFE 170

Car Battery Charger Instructions for Use

F3S-TGR-KHL1/-KHL3/-KHL3R

HD18F2M1.

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

! C A U T I O N! Damages on the machine possible.

VEM motors Thurm GmbH

Effective discrimination of protective devices

Owners Manual: - Pumps

1.Safe testing IMPORTANT:

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

TESTER SET SOCKET & VOLTAGE

Clamping and drive module

Wind Power Inverter WINDY BOY 5000A/6000A

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

OPERATING INSTRUCTIONS

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Installation instructions

Operating Instructions Pedestrian Turnstile Type MPT 33

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Operating Instructions LEO 23 GT

Element C8.3 Installation, Use and Inspection of Electrical Systems

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

OPERATING INSTRUCTION

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Wilo-Control SC-Fire Jockey

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Assembly and Maintenance Manual Type AS

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Monitor and Review. Electrical Safety. Causeway Coast and Glens Borough Council HSPD 009

HF 05/B Mechanical Load Cell

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Instructions for Use Plain Trolley ULK Geared Trolley UHK

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

INSTRUCTIONS INSTALLATION OF LOAD-SHARE TERMINALS FOR VLT DRIVES

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

Guidance to Installers of Viridian EV Charging Stations

LINE CONDITIONERS USER'S GUIDE

Bimetal Overload Relays 3UA and 3UC

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Installation and Operation Manual

NUFORS-DC VALVE SERVICE

Electro-hydraulic crimping tool AH-12. Art convincing solutions. Video

Accessory Fitting Instructions

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

Assembly and operating Instructions RA 60 / FA 60

Timing-Belt Reverse Unit 8 80 R25 Notes on Use and Installation

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Transcription:

en Electrical operating instructions ELEKTROMATEN without reversing contactor with / without terminal box with / without magnetic brake 51171321 - c 03.2010

OPERATING INSTRUCTIONS 52210079 consisting of: M : Mechanical operating instructions (separately enclosed) E : Electrical operating instructions List of Contents E Page SAFETY DIRECTIONS...E 3 ELECTRICAL CONNECTION OF TERMINAL BOX... E 5 ELECTRICAL CONNECTIONS... E 6 WIRING MOTOR AND BRAKE...E 7 WIRING DIAGRAMM WITHOUT LIMIT SWITCH...E 8 WIRING DIAGRAMM WITH LIMIT SWITCHES; WITH MAGNETIC BRAKE; 3 x 400V WITH NEUTRAL...E 9 www.gfa-elektromaten.de

SAFETY DIRECTIONS 52220013 Basic Directions This control has been built in accordance with EN 12453 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements; and left the factory in perfect condition from the point of view of safety. To maintain this condition and to ensure safe operation, the user must observe all the directions and warnings contained in these operating instructions. In principle, only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. Reconstruction of or changes to ELEKTROMAT are only permissible with the approval of the manufacturer. Original replacement parts and accessories authorised by the manufacturer guarantee safety. Liability ceases to apply if other parts are used. The operational safety of an ELEKTROMATEN is only guaranteed if it is used in accordance with the regulations. The limiting values stated in the technical data should not be exceeded under any circumstances (see corresponding sections of the operating instructions). Safety Regulations During the installation, initial operation, maintenance and testing of the ELEKTROMATEN, it is necessary to observe the safety and accident-prevention regulations valid for the specific application. In particular, you should observe the following regulations (this list is not exhaustive): European normative - EN 12453 Safety in use of power operated doors - Requirements - EN 12445 Safety in use of power operated doors - Test methods Please check normative bellow. VDE-regulations - EN 418 Safety machinery Emergency stop equipment functional aspects Principles for design - EN 60204-1 / VDE 0113-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements - EN 60335-1 / VDE 0700-1 Safety of household and similar electrical appliances - Part 1: General requirements Regulations - Please ensure that the local regulations relating to the Safety of Operations of Doors are followed E 3

SAFETY DIRECTIONS 52220004 Explanation of warnings These operating instructions contain directions which are important for using the ELEKTRO- MATEN appropriately and safely. The individual directions have the following meaning: DANGER This indicates danger to the life and health of the user if the appropriate precautions are not taken. CAUTION This warns that the ELEKTROMATEN or other materials may be damaged if the appropriate precautions are not taken. General warnings and safety precautions The following warnings are to be understood as a general guideline for working with the ELEKTROMATEN in conjunction with other devices. These directions must be observed strictly during installation and operation. Please observe the safety and accident prevention regulations valid for the specific application. The installation of the ELEKTROMATEN, the opening of covers or lids and electrical connection must be carried out when the supply is switched off. The ELEKTROMATEN must be installed with the authorised coverings and protective devices. Care should be taken that any seals are fitted correctly and screw couplings are tightened correctly. In the case of ELEKTROMATEN with a permanent mains connection, an all-pole main switch with appropriate back-up fuse must be provided. Check live cables and conductors regularly for insulation faults or breakages. When a fault is detected in the cabling, the defective cabling should be replaced after immediately switching off the mains supply. Before starting operation, check whether the permissible mains voltage range of the devices corresponds to the local mains voltage. Emergency stop devices in accordance with VDE 0113 (EN60204) should remain operational in all operating modes of the control. Releasing the emergency stop device should not cause any uncontrolled or undefined restart. E 4

ELECTRICAL CONNECTION OF TERMINAL BOX 52310031 Warning! Danger to life through electric shock Before starting assembly, disconnect the cables from the electricity supply and check that they are dead. Only trained electrical craftsmen should work on electrical equipment. They must assess the work which has been assigned to them, identify potential danger sources and take suitable safety precautions. The following tools are recommended for the appropriate electrical connection of the ELEKTRO- MATEN : - Multimeter (for alternating current up to at least 750VAC) - Electrically insulated screw driver - Cable stripper - Diagonal cutter - Piercing tool for opening the cable ducts - Wire end ferrules with associated crimp tool when using flexible cables In order to connect the ELEKTROMATEN electrically, the lid of the terminal box housing must first be removed. After loosening the two lid screws, the housing lid can be swivelled about 45 (Fig.1) and removed. The cable ducts in the terminal box housing must be opened with a piercing tool. The hole in the cable duct should be smaller than the cable diameter to ensure sealing. When the cable duct is opened with a knife or a screw driver, sealing cannot be guaranteed. If necessary, the complete terminal box housing can be removed, after loosening the two mounting screws, and mounted next to the ELEKTROMATEN. Fig. 1: Terminal box housing The inserted cables are connected in accordance with the terminal diagram. The 3 motor phases of the external control are connected to the terminals U/V/W. The neutral is to connect, at power supply of 3x400V, at terminal designated N. The PE conductor is connected to the terminals designated PE. Check that all screw connections are secure before operating the control on the attachment side and adjusting the limit switches. E 5

ELECTRICAL CONNECTIONS 52310049 The use of non-interchangeable connectors for the limit switch make it easy to assemble and/or change the reversing contactor board. When doing so, the following steps should be carried out: Disassembly: - Remove limit switch cover - Detach the plug from the limit switch board; after pulling the upper end of the plug, the entire plug can be pulled out easily (Fig. 1, whilst doing so, hold the entire limit switch board firmly with the other hand) - Pull out 5 - pole motor plug and PE (Fig. 2 / 3 / 4) - Pull the connecting cable for the reversing contactor housing, together with the cable duct, out of the gearbox housing Assembly: - Insert the connecting cable with the cable duct into the gearbox housing - Plug in 5 - pole motor socket (Fig. 2 / 3 / 4) - Insert the limit switch plug whilst holding the entire limit switch board firmly with the other hand (Fig. 1) - Check limit switch adjustment - Mount limit switch cover Fig. 1: Limit switch plug Fig. 2: Motor Terminal Rail for 3x400V/230V Fig. 3: Motor Terminal Rail for single-phase motor asymmetric winding Fig. 4: Motor Terminal Rail for single-phase motor symmetric winding E 6

WIRING MOTOR AND BRAKE 52370168 Magnetic locking deveice Parking brake N W PE V U Ext. 230V/AC N W PE V U 3 x 400V, N, PE 3 x 400V, PE M1 3~ M1 3~ Ext. 230V/AC N W PE V U N W PE V U 3 x 230V, PE M 3~ M1 3~ Ext. 230V/AC Z1 PE UZ2 U1 Z1 PE UZ2 U1 1 x 230V, N, PE sym. winding M1 M 1~ 1~ -C1 -C1 Ext. 230V/AC U2 Z1 PE Z2 U2 Z1 PE Z2 1 x 230V, N, PE asym. winding M1 1~ M1 1~ -C1 -C1 Description Print: - C1 Capacitor - G1 Rectifier - M 1 Motor - Y1 Brake E 7

WIRING DIAGRAMM WITHOUT LIMIT SWITCH 52370125 1 M + - E 8

WIRING DIAGRAMM WITH LIMIT SWITCHES; WITH MAGNETIC BRAKE; 3 x 400V WITH NEUTRAL 52370169 When setting the limit please use the description mentioned in the mechanical direction. When the coarse adjustment is finished the exact switching point can be adjusted with fine adjustment screw. The 2 off potential free auxiliary limits can be used as a NO or NC contact and they working in either running direction of the door. Model with 5th and 6th additional limit switches The following diagram shows the connection between the limit switch board 6 micro and the terminal box (OPTION). Connect all limit contacts and motor connection into this terminal box. 230V connection separately the magnetic brake. N (NEUTRAL) must be connect other wise brake damage. + - E 9