PY, SPY; FSQC, FP; EPC; AP

Similar documents
YFC. Limit switch. Ex d. 24 operating head types

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Junction boxes for control, monitoring and control panel Ex tb

CCAI, CCAIF, CCAIF..H

M-0. M-0... series control, monitoring and signalling devices. Ex e

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

FHL. Ex d. Body in aluminium

EWE. Ex de. Cooling fins

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EWE. Cooling fins. Ex de

P, I, A. Command and control stations Ex e

EXEL-L. Detail of the internal side. Transparent polycarbonate

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

EVE. Silicon gasket. Ex de

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear luminaire with LED Series EXLUX 6002

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

EX-D ENCLOSURES AND DISTRIBUTIONS

Linear Luminaire with LED Series EXLUX 6002

A good connection. International approvals.

Floodlight Series 6121

New products Ex Equipment 2015

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire with LED Series EXLUX 6402/2

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Floodlight LED Series 6125

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Compact Sheet-Steel Light Fittings Series 6114/1

Emergency Light Fitting for Fluorescent Lamps Series 6009

Plug and Socket Devices SolConeX 16 A Series 8570

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

INSTRUCTION MANUAL (ATEX / IECEx)

Floodlight LED Series 6525

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

Floodlight LED Series 6525

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Floodlight Series 6521/4

INSTRUCTION MANUAL (ATEX / IECEx)

Compact Sheet-steel Emergency Light Fitting Series 6118/1

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

EX-REPAIR AND MAINTENANCE RECEPTACLES

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

10 Load and Motor Switchgear

LED Linear Luminaire Series EXLUX 6402

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Position Switches Series 8074/2

STAINLESS STEEL PANEL MOUNT

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Unused flameproof threads for cable glands have to be closed with certified plugs.

HTSB system System overview

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Solenoid coils VACF Type codes

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Operating Instructions

Spring loaded resistance thermometer

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Control Buttons / Switches for Panel Mounting Series 8003

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Panelboards & Motor Starters

Tubular Light Fitting with LED Series 6036

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Terminal Boxes in Stainless Steel SLS**.T

COMBUSTION AND ENERGY

PRE Series 63 Amp Plugs and Sockets Increased Safety

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Position Switches Series 8070/2

A good connection. International approvals.

PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES

Operating Instructions

VALIADIS S.A. HELLENIC MOTORS

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Position Switches Series 8060/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

OPERATING INSTRUCTIONS

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Ex m Solenoid Operator Type 0519

ATX DPD Series Distribution Panelboards Flameproof

Transcription:

Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester coating RAL7035 Earthing bolt with rod to prevent cable from twisting Steel chain Cast metal fixing lugs D.1 ED.2018

PY, SPY Series Sockets and plugs from 16 A to 32 A Ex d PY series sockets are equipped with an interlocked disconnect switch with the plug positioned beneath. The rotary movement together with the closing/opening operations which occur inside a special explosion-proof chamber ensure any explosion in the presence of gas is contained. The electric circuit is connected only after the SPY series plug has been correctly inserted into its seat, and ensures it can only be removed once the electrical circuit has been disconnected. The range includes two pole sockets + earth (PE); three pole sockets + earth (PE) and three pole sockets + neutral + earth (PE), with a current capacities of 16A and reduced overall dimensions, up to a maximum of 32A. Voltages range from 20V to a maximum of 690VAC, with a maximum frequency of 500Hz. These sockets can be used in any environment with a potentially explosive atmosphere, and are manufactured so they cannot be used with industrial type plugs. Cortem Group applies a tamper-evident holographic security label to its products, complete with a unique authentication numeric code, to combat the illegal sale of imitations and counterfeits, as well as guarantee the authenticity of its products. Failure to observe international standards creates serious risks for the environment and, above all, for the personnel working with the systems on a daily basis. Sectors of application: Petroleum refineries Chemical and petrochemical plants Onshore facilities Offshore facilities Petroleum loading/unloading pontoons Low temperatures Fuel storage 100% facilities produced by Cortem CERTIFICATION DATA Classification: Group II Category 2GD Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2 GD Ex d IIC T6 Gb; Ex tb IIIC T76 C Db IP66 Certificate: ATEX CESI 14 ATEX 017X IEC Ex CES 11.0011X INMETRO DNV 16.0099U TR CU B.02181 For all IEC Ex, INMETRO, TR CU and TR CU certification data, download the certificate from www.cortemgroup.com CCoE P411913 Standards: Temperature class: CENELEC EN 60079-0: 2012, EN 60079-0/A11: 2013, EN 60079-1: 2014, EN60079-31: 2014 and European Directive 2014/34/EU. IEC 60079-0: 2011, IEC 60079-1: 2014, IEC 60079-31: 2013 RoHS Directive 2002/95/EC. 76 C (T6) Ambient temp.: -20 C +55 C Degree of protection: IP66 A QR reader is required to access the information contained in the QRCode. Centre the QR code in the frame of your smartphone camera. Your smartphone will open the corresponding address. ATEX Certificate IECEx Certificate Use and maintenance instructions ED.2018 D.2

Ex d PY, SPY Series Sockets and plugs from 16 A to 32 A PY SPY MECHANICAL FEATURES Socket body: Low copper content aluminium alloy, complete with wall fastening lugs and threaded socket closure cap attached to body with a safety chain Lid: Screw fastened, aluminium alloy with low copper content. Used to access socket and make electrical connection Plug: Low copper content aluminium alloy, complete with colour coded plastic lock rings to identify the mains power supply voltage Pins: Nickel-plated brass Gaskets: Acid, hydrocarbon and high temperature resistant silicon positioned between the body and the lid Certificate label: Adhesive affixed to external surface Screws: Stainless steel Earth screw: M5 outdoor and indoor Coating: Polyester RAL 7035 (Light grey) Threaded entry points: One upper and one lower Ø 1 or 3/4 : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot-humid cycles) and EN60068-2-11 (salt fog test) Safety system: The sockets have an interlocked disconnect switch with plug. The rotary movement together with the closing/opening operations which occur inside a special explosion-proof chamber ensure any explosion in the presence of gas is contained. The electrical circuit is connected only after the SPY series plug has been correctly inserted into its seat, and ensures it can only be removed once the electrical circuit has been disconnected. These sockets are unique in that they can be equipped with SPY series plugs which can also be used with industrial solder type sockets. This feature is unique to the Cortem Group, and is designed to allow the user to keep a limited stock of spare parts compared to competitor sockets which do not have this specification. In fact, the position of the phase and earth pins, together with the coloured lock rings which comply with the colour code required by IEC/EN 60309-2 for industrial sockets and plugs, identify them according to the power supply voltage and current used. For a better understanding, we have included the earth pin (PE) positioning drawing and relative colours, in compliance with IEC/EN 60309-2, for voltages greater than 50V. D.3 ED.2018

PY, SPY Series Sockets and plugs from 16 A to 32 A Ex d ELECTRICAL FEATURES Rated voltage: Max. 690 Vac Rated frequency: Max. 500 Hz Rated current: 16A and 32A Cable entry: no. 2 on the socket and no. 1 on the plug Max. cable cross-section: for 16A: 4 mm 2 for 32A: 6 mm 2 DIMENSIONAL DRAWING PY Socket SPY Plug A Ød Dimensions in mm MODEL DIMENSIONS (mm) A B C y x w Ø d WEIGHT (Kg) PY..16.. Ø 90 165 135 104 50 8 3/4 ISO7/1 1.7 PY..32.. Ø 120 240 175 140 80 8 1 ISO7/1 2.1 SPY..16.. Ø 66 116 - - - - 3/4 ISO7/1 0.3 SPY..32.. Ø 92 145 - - - - 1 ISO7/1 0.6 ED.2018 D.4

Ex d PY, SPY Series Sockets and plugs from 16 A to 32 A CODE SELECTION TABLE RATED CURRENT NUMBER OF POLES FREQUENCY Hz RATED VOLTAGE Vac ARRANGEMENT WEIGHT (Kg) SOCKET CODE PLUG CODE 50 / 60 200 / 250 1.70 PY216B SPY216B 50 / 60 100 / 130 1.70 PY216G SPY216G 50 / 60 20 / 25 1.70 PY216V SPY216V 50 / 60 380 / 415 1.70 PY216R SPY216R 16 A 50 / 60 40 / 50 1.70 PY216BI SPY216BI 50 / 60 200 / 250 1.70 PY316B SPY316B 50 / 60 100 / 130 1.70 PY316G SPY316G 50 / 60 20 / 25 1.70 PY316V SPY316V 50 / 60 380 / 415 1.70 PY316R SPY316R 50 / 60 200 / 250 2.10 PY232B SPY232B 50 / 60 40 / 50 2.10 PY232BI SPY232BI 32 A 50 / 60 100 / 130 2.10 PY232G SPY232G 50 / 60 380 / 415 2.10 PY232R SPY232R 50 / 60 20 / 25 2.10 PY232V SPY232V 50 / 60 50 2.10 PY232VE SPY232VE D.5 ED.2018

PY, SPY Series Sockets and plugs from 16 A to 32 A Ex d CODE SELECTION TABLE RATED CURRENT NUMBER OF POLES FREQUENCY Hz RATED VOLTAGE Vac ARRANGEMENT WEIGHT (Kg) SOCKET CODE PLUG CODE 50 / 60 200 / 250 2.10 PY332B SPY332B 50 / 60 100 / 130 2.10 PY332G SPY332G 50 / 60 500 2.10 PY332N SPY332N 50 / 60 380 / 415 2.10 PY332R SPY332R 50 / 60 440 2.10 PY332RR SPY332RR 50 / 60 20 / 25 2.10 PY332V SPY332V 32 A 50 / 60 50 2.10 PY332VE SPY332VE N + 50 / 60 200 / 250 2.10 PY432B SPY432B N + 50 / 60 100 / 130 2.10 PY432G SPY432G N + 50 / 60 500 2.10 PY432N SPY432N N + 50 / 60 380 / 415 2.10 PY432R SPY432R N + 50 / 60 440 2.10 PY432RR SPY432RR N + 50 / 60 50 2.10 PY432VE SPY432VE Features comply with CEI EN 60309-1/60309-2 ED.2018 D.6

Ex d PY, SPY Series Sockets and plugs from 16 A to 32 A ILLUSTRATION DESCRIPTION MODEL FEATURES CODE LEGEND Material: Cable gland 3/4 NPT nickel-plated brass std. cable range 11 to 20 NAV2NB Cap 3/4 NPT Material: nickel-plated brass PLG2NB Rotary disconnect switch PY216 2P+T 16A 690V A2-10E/S PY232 2P+T 32A 690V A2-32E/A PY316 3P+T 16A 690V A3-10E/S PY332 3P+T 32A 690V A3-32E/A PY432 3P+N+T 32A 690V A4-32E/A RICAMBIO SPY216... M16-523/... Coloured ring with bayonet connection SPY316... SPY332... The rated voltage or frequency of each plug is identified by its colour M16-751/... M32-523/... RICAMBIO SPY432... M-766/... SPY216... M16-543/... Coloured cap with bayonet connection and safety chain to prevent losing cap SPY316... SPY332... The rated voltage or frequency of each plug is identified by its colour M16-750/... M32-543/... RICAMBIO SPY432... M-767/... Special application - portable socket and plug Portable socket comprised of: - CCA-03E housing with internal frame and pre-installed 230/110V terminals and transformer - PY-216G socket, 110V, 1P+N+T - SPY-216B plug, 230V, 1P+N+T complete with 30 m of 3G2.5 cable - SPY-216G plug, 110V, 1P+N+T - easy to use, powder coated steel trolley Electrical arrangement D.7 ED.2018

FSQC, FP Series Sockets and plugs from 10 A to 63 A Ex d FSQC series sockets are manufactured in two phase + earth (PE) and three phase + earth (PE) versions. They are therefore suitable for single phase or three phase loads. They have an automatic circuit breaker with both thermal (overload) protection and magnetic (short circuit) protection with a typical "C" curve for electrical loads and a fixed factory default trip current threshold. The range includes two pole sockets + earth (PE), three pole sockets + earth (PE), with a current capacities from 10A up to a maximum of 63A, maximum voltage of 690VAC and frequency of 50/60Hz. Cortem has chosen to adopt industrial type switches for these sockets, as well, and they can be equipped with 63A FP series plugs. These sockets can be used in any environment with a potentially explosive atmosphere, and are manufactured so they cannot be used with industrial type plugs. Cortem Group applies a tamper-evident holographic security label to its products, complete with a unique authentication numeric code, to combat the illegal sale of imitations and counterfeits, as well as guarantee the authenticity of its products. Failure to observe international standards creates serious risks for the environment and, above all, for the personnel working with the systems on a daily basis. Sectors of application: Petroleum refineries Chemical and petrochemical plants Onshore facilities Offshore facilities Petroleum loading/unloading pontoons Low temperatures Fuel storage 100% facilities produced by Cortem EMPTY ENCLOSURE CERTIFICATION DATA Classification: Group II Category 2GD Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2 GD; Ex d IIC T6 Gb; Ex tb IIIC T85 C Db IP65 Certificate: ATEX CESI 04 ATEX 043 IEC Ex CES 11.0012X For all IEC Ex and TR CU certification data, download the certificate from TR CU B.02181 www.cortemgroup.com Standards: Temperature class: CENELEC EN 60079-0: 2012, EN 60079-1: 2007, EN60079-31: 2009 and European Directive 2014/34/EU. IEC 60079-0: 2010, IEC 60079-1: 2007, IEC 60079-31: 2008 RoHS Directive 2002/95/EC. 85 C (T6) Ambient temp.: -20 C +40 C Degree of protection: -20 C +55 C With internal 100A rated current switch With internal 125A rated current switch IP65 A QR reader is required to access the information contained in the QRCode. Centre the QR code in the frame of your smartphone camera. Your smartphone will open the corresponding address. ATEX Certificate IECEx Certificate Use and maintenance instructions ED.2018 D.8

Ex d FSQC, FP Series Sockets and plugs from 10 A to 63 A FSQC FP MECHANICAL FEATURES Socket body: Lid: Plug: Pins: Gaskets: Certificate label: Screws: Earth screw: Coating: Threaded entry points: Safety system: Low copper content aluminium alloy, complete with wall fastening lugs and threaded socket closure cap attached to body with a safety chain Screw fastened, aluminium alloy with low copper content. Used to access socket and make electrical connection Low copper content aluminium alloy, complete with plastic lock rings Nickel-plated brass Acid, hydrocarbon and high temperature resistant silicon positioned between the body and the lid Adhesive affixed to external surface Stainless steel M6 outdoor, M5 indoor Polyester RAL 7035 (Light grey) One upper and one lower Ø 1 (FSQC-2...) One upper and one lower Ø 1 1/2 (FSQC-3...) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot-humid cycles) and EN60068-2-11 (salt fog test) The sockets have an interlocked disconnect switch with plug. The rotary movement together with the closing/opening operations which occur inside a special explosion-proof chamber ensure any explosion in the presence of gas is contained. The electrical circuit is connected only after the SPY series plug has been correctly inserted into its seat, and ensures it can only be removed once the electrical circuit has been disconnected. Internal layout of power and switching modules, in main markings (front view of FSQC socket) Marking 2P+T 220V-250V Brown Marking 2P+T 115V-125V Brown Marking 2P+T 115V-125V N L1 Blue Blue L3 L2 Marking 3P+T 380V-415V L1 Marking 3P+T 220V-250V L2 L3 Marking 3P+N+T 220V-250V L3 L2 N L3 L2 L1 L1 D.9 ED.2018

FSQC, FP Series Sockets and plugs from 10 A to 63 A Ex d ELECTRICAL FEATURES Rated voltage: Max. 440 V Rated frequency: Max. 50/60 Hz Rated current: From 10 A to 63 A Cable entry: no. 2 on the socket and no. 1 on the plug Max. cable cross-section: Max. 10 mm 2 DIMENSIONAL DRAWING FSQC Socket FP Plug Dimensions in mm CODE SELECTION TABLE SOCKETS NUMBER OF POLES MAX. CAPACITY (A) ENTRY POINTS WEIGHT (Kg) SOCKET CODE 10 A 2 x 1 3.15 FSQC-23310 15 A 2 x 1 3.15 FSQC-23315 20 A 2 x 1 3.15 FSQC-23320 30 A 2 x 1 3.15 FSQC-23330 40 A 2 x 1 3.15 FSQC-23340 50 A 2 x 1 3.15 FSQC-23350 63 A 2 x 1 3.15 FSQC-23363 10 A 2 x 1 3.37 FSQC-23410 15 A 2 x 1 3.37 FSQC-23415 20 A 2 x 1 3.37 FSQC-23420 30 A 2 x 1 3.37 FSQC-23430 40 A 2 x 1 3.37 FSQC-23440 50 A 2 x 1 3.37 FSQC-23450 63 A 2 x 1 3.37 FSQC-23463 ED.2018 D.10

Ex d FSQC, FP Series Sockets and plugs from 10 A to 63 A CODE SELECTION TABLE SOCKETS NUMBER OF POLES MAX. CAPACITY (A) ENTRY POINTS WEIGHT (Kg) SOCKET CODE 10 A 2 x 1 1/2 3.05 FSQC-33310 15 A 2 x 1 1/2 3.05 FSQC-33315 20 A 2 x 1 1/2 3.05 FSQC-33320 30 A 2 x 1 1/2 3.05 FSQC-33330 40 A 2 x 1 1/2 3.05 FSQC-33340 50 A 2 x 1 1/2 3.05 FSQC-33350 63 A 2 x 1 1/2 3.05 FSQC-33363 10 A 2 x 1 1/2 3.27 FSQC-33410 15 A 2 x 1 1/2 3.27 FSQC-33415 20 A 2 x 1 1/2 3.27 FSQC-33420 30 A 2 x 1 1/2 3.27 FSQC-33430 40 A 2 x 1 1/2 3.27 FSQC-33440 50 A 2 x 1 1/2 3.27 FSQC-33450 63 A 2 x 1 1/2 3.27 FSQC-33463 PLUGS NUMBER OF POLES MAX. CAPACITY (A) ENTRY POINT FOR SOCKET TYPE WEIGHT (Kg) PLUG CODE 63 A 1 x 1 FSQC-2... 0.82 FP-23 63 A 1 x 1 FSQC-3... 0.83 FP-24 Example installations Socket sets FSQC-23450 and FSQC- 23315, mounted on a galvanised steel column, complete with an SA302318 'Ex e' type terminal housing, junction fittings, entry point cable glands, and FP-24 and FP-23 plugs. Socket enclosure comprised of: A. FSQC-23463 socket; 380V, 63A, 3p+T B. PY216B socket; 220V, 16A, C. SA302310/P housing with 35 mm 2 terminals D. SA141410/P housing with 4mm 2 terminals A. FP-24 socket; 380V, 63A, 3p+T A B E C D D.11 ED.2018

EPC, EPRC, AP Series Sockets and plugs from 63 A to 125 A Ex d EPC and EPRC sockets are particularly suitable for powering utility currents above 32A (up to a maximum of 125A), such as filter press systems for the reclamation and regeneration of oil from large power transformers, large welding machines, electro-pneumatic compressors, generators and a whole series of large mobile utilities required for the maintenance and or updating process elements. EPC and EPCR series sockets, precisely because they must be suitable for significantly large electric loads, are equipped with an automatic circuit breaker with both thermal (overload) protection and magnetic (short circuit) protection with a typical "C" curve for electrical loads and a fixed factory default trip current threshold. The range includes three pole sockets + earth (PE) and three pole sockets + Neutral + earth (PE), with a current capacities of 63A and 125A, with a maximum voltage of 500VAC. They can be equipped with 125A AP series plugs. Cortem Group applies a tamper-evident holographic security label to its products, complete with a unique authentication numeric code, to combat the illegal sale of imitations and counterfeits, as well as guarantee the authenticity of its products. Failure to observe international standards creates serious risks for the environment and, above all, for the personnel working with the systems on a daily basis. Sectors of application: Petroleum refineries Chemical and petrochemical plants Onshore facilities Offshore facilities Petroleum loading/ Low Fuel storage 100% unloading temperatures facilities produced by pontoons Cortem EMPTY ENCLOSURE CERTIFICATION DATA Classification: Group II Category 2GD Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2 GD; Ex d IIC T6 Gb; Ex tb IIIC T85 C Db IP66 Certificate: ATEX CESI 03 ATEX 198 IEC Ex IECEx CES 16.0008 For all IEC Ex and TR CU certification data, download the certificate from TR CU B.02181 www.cortemgroup.com Standards: Temperature class: CENELEC EN 60079-0: 2012, EN 60079-1: 2007, EN60079-31: 2009 and European Directive 2014/34/EU. IEC 60079-0: 2010, IEC 60079-1: 2007, IEC 60079-31: 2008 RoHS Directive 2002/95/EC. 85 C (T6) Ambient temp.: -20 C +40 C Degree of protection: -20 C +55 C With internal 100A rated current switch With internal 125A rated current switch IP66 A QR reader is required to access the information contained in the QRCode. Centre the QR code in the frame of your smartphone camera. Your smartphone will open the corresponding address. ATEX Certificate IECEx Certificate Use and maintenance instructions ED.2018 D.12

Ex d EPC, AP Series Sockets and plugs from 63 A to 125 A EPC AP MECHANICAL FEATURES Socket body: Lid: Plug: Pins: Gaskets: Certificate label: Screws: Earth screw: Coating: Threaded entry points: Safety system: Low copper content aluminium alloy, complete with wall fastening lugs and threaded socket closure cap attached to body with a safety chain Screw fastened, aluminium alloy with low copper content for opening socket and making electrical connection Low copper content aluminium alloy, complete with plastic lock rings Nickel-plated brass Acid, hydrocarbon and high temperature resistant positioned between the body and the lid Metal, affixed externally Stainless steel M6 outdoor and indoor Polyester RAL 7035 (Light grey) Two upper and two lower Ø 1 1/2 (EPC) Two upper Ø 1 1/2 (EPRC..) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot-humid cycles) and EN60068-2-11 (salt fog test) The external control lever and mechanically interlocked safety system prevents the electrical circuit from closing if the plug has not been correctly inserted in its explosion-proof housing, and prevents extraction if the automatic circuit breaker has not be opened previously. These sockets can be used in any environment with a potentially explosive atmosphere, and are manufactured so they cannot be used with industrial type plugs. Circuit breaker operation Internal circuit breaker in "ON" position Internal circuit breaker in "OFF" position The plug cannot be removed from the socket if the switch is in the "ON" position (with the handle facing upwards) or, in any event, if the "e" references are not aligned on the same axis. D.13 ED.2018

EPC Series EPRC, AP Sockets and plugs from 63 A to 125 A Ex d ELECTRICAL FEATURES Rated voltage: Max. 690 V Rated frequency: Max. 50/60 Hz Rated current: From 63 A to max. 125 A Cable entry: Socket EPC 4 holes Ø 1 1/2" Socket EPRC 2 holes Ø 1 1/2 Plug AP 1 hole Ø 1 1/4 Max. cable cross-section: Max. 50 mm 2 DIMENSIONAL DRAWING EPC Socket AP Plug Dimensions in mm EPRC Socket AP Plug Dimensions in mm ED.2018 D.14

Ex d EPC, EPRC, AP Series Sockets and plugs from 63 A to 125 A CODE SELECTION TABLE SOCKETS NUMBER OF POLES MAX. CAPACITY (A) CASING TYPE WEIGHT (Kg) SOCKET CODE 63 A GUB-03 14 EPC1-1Q63B N + 63 A GUB-03 14 EPC1-1P63B 125 A GUB-03 14 EPC1-1Q125B N + 125 A GUB-03 14 EPC-1P125B 63 A CCA-03E 14 EPRC1-1Q63B N + 63 A CCA-03E 14 EPRC1-1P63B 125 A CCA-03E 14 EPRC1-1Q125B N + 125 A CCA-03E 14 EPRC1-1P125B PLUGS NUMBER OF POLES MAX. CAPACITY (A) WEIGHT (Kg) PLUG CODE N + 125 A 2 AP-4125 125 A 2 AP-5125 Socket combination unit Electrical arrangement D A B C E Socket enclosure comprised of: A. EPC1-1P32B socket, 3p+N+T, 400V, with MCCB 32A 18kA A. EPC1-1P63B socket, 3p+N+T, 400V, with MCCB 63A 18kA C. CCA-02C housing with MCB 16A, 2P, 'C' curve for 18kA B. PY216B socket, 2p+T, 230V 16A 18KA D. SAG473018 Cortem aluminium housing E. Galvanized steel "U" profile support frame, 80x45 D.15 ED.2018

Example installations Ex d TROLLEY MOUNTED SOCKET UNIT ASSEMBLY SIDE VIEW INTERNAL VIEW OF CASING Unit comprised of: - Three PY216B sockets, 2p+T, 16A, 230Vac and three SPY216B plugs. - Two PY432R sockets, 3p+N+T, 32A, 380/415Vac and two SPY432R plugs. - GUB-04 housing, complete with circuit breaker. - Cable suitable for extremely high mechanical stresses, and is resistant to both oils and chemicals, 4x35 + 1x35PE mm 2, L=30m. - One AP5125 plug, 4p+T (400/230Vac supply line). - Steel trolley with rubber wheels, RAL3020 powder coated. ELECTRICAL ARRANGEMENT ED.2018 D.16

Ex d Example installations ELECTRICAL DISTRIBUTION PANEL WITH INTERLOCKED SOCKETS A D G FRONT VIEW B J H C E F I LAYOUT 3D Socket enclosure comprised of: A. An EJB-4B aluminium housing with a boxed automatic switch and control lever, relay protection, reset button, fuse and toroidal transformer. B. An EPRC1-1Q100B with 3p+T, 100A, 600V, with an interlocked automatic switch. C. One AP-4125 plug, 3p+T, max. 125A. D. An EJB-55 aluminium housing with a boxed automatic switches and control handles, relay protection, reset buttons, fuses and toroidal transformers. E. Four PY232B sockets, 2p+T, 32A, 200/250V with interlocked switch. F. Four SPY232B plugs, 2p+T, 32A. G. An EJB-6 housing with a 1000VA 120/24V 60Hz transformer, boxed automatic switch and control lever, relay protection, reset button, fuse, toroidal transformer, and green signalling light. H. Two PY232G sockets, 2p+T, 32A, 110/130V with interlocked switch; one PY232V socket, 2p+T, 32A, 20/25V with interlocked switch. I. Two SPY232G plugs, 2p+T, 32A, 110/130V; one SPY232V plug, 2P+T, 32A, 20/25V. J. Galvanized steel "U" profile support frame, 100x50. Lock and junction fittings. D.17 ED.2018

ED.2018 D.18 Ex d