Wireless Radiator Valve

Similar documents
Instruction Manual. For model: JGTRV. speedfitufh.co.uk

2 PORT MOTORISED VALVE (28 mm)

2 PORT MOTORISED VALVE (22 mm)

3 PORT MOTORISED VALVE (32/38 mm)

3 PORT MOTORISED VALVE (22 mm)

WPT Installation Manual. Wireless Pneumatic Thermostat- WPT-800 Series. 1. Overview. 1.1 Parts Included. 1.2 Prerequisites for Installation

Digital Room THERMOSTAT for Model No. RT300

TIRE PRESSURE MONITORING SYSTEM TPMS 2.0

GloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II

TIRE PRESSURE MONITORING SYSTEM TPMS 1.0

2-Way Dimmer (1 Gang)

Remote Vehicle Control System CA-150. Owner's Manual. Vehicle Security System With Remote Keyless Entry

Plug-in On/Off Socket Kit

Dimmer / 2-Way Dimmer

EC20 Pocket Conductivity Tester Instruction Manual

Installation and User Manual. with RAIN SENSOR.

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21

CA 170 Owner's Manual

Owner s Guide CARS & CA4B5

OWNER S MANUAL HC1/HC2 INSTRUCTIONS EN FRANÇAIS AU VERSO

Remote Vehicle Control System. Keyless Entry and Convenience System

Operating instructions Flow monitor SI / / 2013

Plug-in Dimmer Socket Kit

WiFi Tank Level Monitor Installation Instructions

Owner s Guide APS596Z

ECscan20 Pocket Conductivity Tester Instruction Manual

L I M I T E D L I F E T I M E W A R R A N T Y

ACS LED SIGNALLING UNIT LINEAR SENSOR CALIBRATION. AS-i module / multi-voltage modules version

M40/50RF System - Installers Guide

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

CA611 Owners Manual CAUTION!

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

ZoneTouch V2 Zone Control System Installation Manual

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

ZT-USB Series User Manual

Operating instructions Flow monitor SI / / 2014

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

SMT-AZC INSTALLATION / OPERATION MANUAL

ca 1553 Owner s Guide

ZN-502 A/S/AS USER MANUAL

PN# A,13-316A,13-317A, , , & TireGard

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

HERZ Electronic room thermostat analog and digital

CA 6550 Owner s Guide

Air Shift Module User Manual

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

E Series CE Approved Intermittent Pilot Ignition Control

Smart Wi-Fi Sprinkler Timer and Flow Meters

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING

Owner s Guide CARS & CA2LCD5

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Operators Guide: RoboSign Stop/Go Traffic Control System

EC1 Pocket Conductivity Tester Instruction Manual

3 40W. Product Introduction. 1440mm(56.7in) 560mm (22in) 440mm (17.3in

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Serena Remote Controlled Shades

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

INSTALL GUIDE IDL-IDS(RS)-BZ2B-[ADS-BZ2]-EN

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

INSTALLATION INSTRUCTIONS

LASER ENHANCED SEMI-AUTOMATIC GRIP OWNER S MANUAL RED LASER GREEN LASER

Melody 1 Platform Lift

Electric Bike Supplement

USER MANUAL LEVER LOCK DIGITAL TOUCHPAD TEMPLATE. 120x165(mm)

TWO-WAY LED MANUAL / AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

INSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN

Wireless Digital Room Thermostat with Night Set-Back

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Flight Systems. Replacement for KASSEC DESCRIPTION

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

7C MERGER M40/50RF SYSTEM INSTALLERS GUIDE

CA 5053 Owner s Guide

Getting started with

CA 650 Owner's Manual

Salt 1 Pocket Salinity Tester Instruction Manual

DLS-TP400 USER S MANUAL

Operators Guide: RoboSign Stop/Go Traffic Control System

GoSafe TPMS 100 USER S MANUAL. Copyright 2016, PAPAGO Inc., All Right reserved.

翔鑫科技股份有限公司. Oro Technology Co., LTD. 無線胎壓監測器 Tire Pressure Monitoring System 型號 : W410

Classic Instruments. Ultimate Speedometer & Speed-Tachular. Installation Manual

INSTALLER MANUAL USER MANUAL. Contents

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

TABLE OF CONTENTS 11.0 WARRANTY

Coating Thickness Gauges

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

INSTALL GUIDE FLCI-IDS(RS)-BZ4-[FLRSBZ4]-EN

Mitsubishi. VFD Manuals

Solar TPMS. Operating Manual

Solar TPMS. Operating Manual

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

INSTALLATION AND OPERATION INSTRUCTION

Owners Manual for TPMS plus GPS

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Hydro-Wiper J. Self-contained Anti-fouling wiper for the Turner Designs Cyclops-7. Installation and Operation Manual

Transcription:

Wireless Radiator Valve Model: TRV10RF INSTALLER MANUAL

Contents of the box Box Contents Icons used in this manual: Safety Important info Your benefit Contents: Box Contents Introduction Product Compliance and Safety Information Installation User Interface Status/LED indication Installers notes Warranty TRV10RF 2x AA Batteries Adapter For latest PDF installation guide please go to www.salus-controls.com Manual 02 TRV10RF Installer Manual

Product Compliance & Safety Information INTRODUCTION Thank you for purchasing the SALUS wireless radiator valve (TRV10RF). The SALUS Wireless Controlled Radiator Valve (RV), simply replaces the passive standard TRV head. The Wireless RV must be used with the wireless thermostat VS10/VS20RF and the Zigbee co-ordinator CO10RF (all sold separately). The wireless radiator valve can be used with the SALUS wireless boiler receiver (RX10RF) configured to RX1 and other it600 wireless products (see below). VS20 Thermostat (Required) CO10RF (Required) RX10RF (Optional) SALUS Wiring Centre KL10RF Product Compliance This product is CE compliant and meets the following EC Directives Electro-Magnetic Compatibility directive 2004/108/EC Low voltage Directive 2006/95/EC. Safety Information Use in accordance with the regulations. The SALUS TRV10RF is to be used for room control inside the house. Installation This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the relevant standards could lead to prosecution. TRV10RF Installer Manual 03

System Overview To achieve the best control from the RV + Thermostat. We recommend that it be used with the SALUS system receiver configured to RX1. The system receiver will turn the boiler on/off as per requested via the thermostat. The RV is modulating, which means it opens or closes partially or 100% depending on the relationship between the actual room temperature and the required room temperature measured by the VS10/20WRF. + Only 3 TRV s can be connected to a VS10WRF/VS20WRF 04 TRV10RF Installer Manual

20 10 mm Checking the compatibility of your heating system The SALUS it600 pack that you have purchased is compatable with most heating systems. Before fitting please check your valve suitable for the TRV to be fitted. 1 Remove your manual TRV head Valve Note: If all the measurements are as stated on this page then the TRV will fit directly to your valve. Also if your valve is not suitable please consider changing your existing valves, contact your installer. 2 30 3 20 10 mm Measure the thread diameter (must measure 30mm) Measure the pin length of the valve when it is in the open possition. (must measure between 13-16mm) TRV10RF Installer Manual 05

Checking the compatibility of your heating system 4 If you can not see any thread on the valve and it looks like this picture, you may be able to use the RA adapter supplied. Our RA adapter also fits this valve. Once fitted the RA adapter should look like this. 06 TRV10RF Installer Manual

Installation - General 1 2 3 Detach top housing by pressing a flat screwdriver into the slot as shown above. Remove the battery cap. Insert the batteries and replace the battery cap. Please note correct battery orientation. 4 5 Gently place the top housing onto the bottom housing. Note correct orientation. Ready to be fitted to the radiator valve. Note: The LED will flash green and then red and eventually go to solid red. Optional adapter. TRV10RF Installer Manual 07

Installation - General 6 7 8 Place the TRV over the radiator valve. Tighten the TRV (finger tight) to the radiator valve. 9 10 11 Check that LED is solid red. Press any button to commence adaptive mode. It is recommended that pairing is done on a room to room basis. Now wait until the unit has completed it s adaptation to the valve. This will be when all noise and LED activity has stopped. If LED continues to flash refer to page 11. The unit is now ready for pairing to the SALUS thermostat. You may now start the pairing process described on page 7. 08 TRV10RF Installer Manual

Installation - Pairing System setup checklist 1 The Zigbee coordinator must be in pairing mode. Before starting the pairing, make sure the light is flashing on the coordinator by holding the button for 5 seconds. Please refer to the coordinator installation guide. 2 Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32 and 37 in the thermostat installation guide. 3 If you are using the optional system receiver configured to RX1 for remote boiler switching. Ensure this has been powered up and the red flashing LED has gone steady. Please refer to system receiver installation guide. TRV10RF Installer Manual 09

User Interface LED Indication Manual open/status indication Manual close/status indication Installation - Pairing 1 Pairing Button Press and hold the pairing button for 10 seconds. 2 Once the red LED starts flashing go to page 37 in the VS20WRF installer manual. When pairing is successful with the VS10WRF/VS20WRF thermostat then the LED will go out. 10 TRV10RF Installer Manual

Using the Unit Auto Lock Function Auto lock function is disabled until you have gone through the pairing process. After pairing, the TRV will auto lock after 5 minute if no buttons have been pressed. Unlocking the Buttons To unlock the buttons, press the pairing and close buttons together for 3 seconds. Opening the Valve Manually Press the open button for 3 seconds. The LED flashes green once and the valve opens. Closing the Valve Manually Press the close button for 3 seconds. The LED flashes red once and the valve closes. Entering Fail Safe Mode In fail safe mode, the unit opens the valve 50% for water flow to maintain room temperature. To enter fail safe mode, press and hold the open and close buttons together for 3 seconds. To exit fail safe mode, press the: Pairing button to put the unit in automatic mode Open button for 3 seconds to open the valve Close button for 3 seconds to close the valve TRV10RF Installer Manual 11

Using the Unit Restoring Factory Default Settings Press the pairing, open, and close buttons together for 10 seconds. Protecting against Frost When you have manually closed the valve, the unit automatically enables frost protection. Frost protection starts only when the temperature in the room drops below the frost temperature setpoint. The unit does all this automatically when connected to a thermostat and you don t have to do anything. Detecting Open Windows The unit checks the rate of temperature drop in the room in which it is located. If the drop is rapid, it assumes a window in the room has been opened. This only works if the unit is paired to the thermostat and is in automatic mode and the battery in the unit is not low. The unit does all this automatically when connected to a thermostat and you don t have to do anything. It works between 0 and 400C. Protecting against Lime Scale Do not leave a valve open for a long time because this could cause a buildup of lime scale. The unit has a lime-scale protection feature to prevent against this. The valve motor automatically starts once a week if no valve movement has been detected within a 14-day period. Lime-scale protection will continue to operate in automatic, manual open, and manual close modes and you don t have to do anything. Auto Adaptation Once the batteries are inserted into the unit, the red light will appear. If no keys are pressed it will auto adapt to the valve. 12 TRV10RF Installer Manual

Button Usage To do this Leave the network Pair with thermostat Put unit in automatic mode Fully open the valve Fully close the valve Press the Pairing button for 10 seconds (when unit already in network) Pairing button for 10 seconds Short press Pairing button Open button for 3 seconds Close button for 3 seconds Restore factory default settings Open, pairing, and close buttons together for 3 seconds Lock and unlock the buttons Pairing and close buttons together for 3 seconds TRV10RF Installer Manual 13

LED Indications When... The LEDs... Valve Power switched Software Version on or after reset indication Unit adapting to valve Unit has not joined network or has not paired to thermostat Unit paired to thermostat and in auto mode Leaving network Identifying the network Auto mode Manual open Manual close A sequence of red and green LEDs flashing displayed indicates the software version Red flashes then goes steady Green flashes (or red flashes on failure to adapt) Green steady Green and red flash (or red flashes on failure to adapt) Green and red flash alternately after short press on open or close button Green flashes twice after short press on open or close button Red flashes twice after short press on open or close button No LED Red and green on together for one second Green flashes for up to 10 minutes 50% open 100% open 0% open 14 TRV10RF Installer Manual

LED Indications When... The LEDs... Valve Wireless Auto mode Green and red flash alternately link to after short press on open or thermostat close button lost Manual open Green flashes twice after short press on open or close button 100% open Manual close Red flashes twice after short press on open or close button 0% open Normal operation Battery low Error installing Auto mode Auto mode Manual open Manual close Window open mode active Green flashes once after short press on open or close button Red flashes once after short press on open or close button Green flashes twice after short press on open or close button Red flashes twice after short press on open or close button Green and red flash twice every 10 seconds Red flashes three times every 10 seconds (less if the battery is low) Green and red flash alternately 1 to 100% open 0% open 100% open 0% open 100% open 50% open TRV10RF Installer Manual 15

Manual Override To remove the unit from auto mode, follow the steps below. If the buttons are locked, unlock them by pressing the pairing and close buttons together for 10 seconds. Long press to manually open unit. LED flashes green once and then goes out. To check status refer to previous page. Long press to manually close unit. LED flashes red once and then goes out. To check status refer to previous page. Short press to return to Auto mode. Red LED will flash once to confirm that the unit is in AUTO. 16 TRV10RF Installer Manual

Technical Detail Model Type TRV10RF Hydraulic Radiator Valve DC Motor M30 x 1.5 Input 3 push buttons. Auto/Open/Close/Pair LED Indicator Bi-Colour, Red/Green Valve Adaptation Automatic Power Source 2 x AA Batteries Battery Life 12 Months Control Method Modulating Communication Zigbee - 2.4GHz Operating Temperature 0 to 50ºC Storage Temperature -20 to 60ºC TRV10RF Installer Manual 17

Installer Notes 18 TRV10RF Installer Manual

Warranty SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name:... Customer Address:...... Post Code:... Tel No:... Email:... Engineers Company:... Tel No:... Email:... Instalation Date:... Engineers Name:... Engineers Signature:... TRV10RF Installer Manual 19

SALUS CONTROLS GMBH DIESELSTRASSE 34 D-63165 MÜHLHEIM AM MAIN EMAIL: INFO@SALUS-CONTROLS.DE TEL: +49 (6108) 82585-0 FAX: +49 (6108) 82585-29 www.salus-controls.de SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. Issue Date: May 2014 00086/2 For PDF Installation guide please go to www.salus-controls.com