SENS DC PowerCab 120 Installation, Operation, & Maintenance Manual

Similar documents
Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Mitsubishi Electric Power Products, Inc. BC55 Battery Cabinet Installation, Operation, & Maintenance Manual

Installation, Operation & Maintenance Manual DataSafe HX Front Terminal Battery Cabinets

ETC SERIES BATTERY CABINET

VRLA Batteries. Battery Installation And Start up Guide

Powerware Vdc Extended Battery Cabinet User s Guide.

Installation And Operation Instructions

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

GVX BATTERY CABINET. Installation documents. for. Electrical integration. Battery installation. Shipping and onsite installation

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Illuminator System Series CM

Installation And Operation Instructions

Sentry Battery Charger. Installation and Operations Manual Section 75

High Frequency SineWave Guardian TM

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Installation And Operation Instructions

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Illuminator System Series CIII

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Owner s Manual. Extended-Run Single-Phase Battery Cabinet. Not suitable for mobile applications.

C&D Technologies, Inc. Dynasty Division 900 East Keefe Avenue Milwaukee, WI53212 Phone: Fax:

LESTRONIC II BATTERY CHARGER MODEL 07210

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Installation and Operations Manual

Installation Instructions and User Manual For. 100 Watt Inverter Power System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

LMI Watt Models

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

SCC-MPPT Solar Charge Controller

MASTERsine Inverter PXA Series Installation Guide

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

FLUSH EYES IMMEDIATELY WITH WATER. GET MEDICAL HELP FAST. SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS.

Solar Charge Controller

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

MIL-24/2600Q MIL-24/3200DQ

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

DC to AC Power Inverters

DC to AC Power Inverters

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

ADI-125/750 ADI-125/1500 ADI-125/2500

AGM Series. Installation Manual AGM Series Modular Battery Systems

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Installation Instructions and User Manual For

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Electrical Installation

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

U N I T Y / Three-Phase Uninterruptible Power Systems UT310, UT315, UT320, UT Hz

C&D TECHNOLOGIES, DYNASTY Division 900 East Keefe Avenue Milwaukee, WI Phone Fax

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Operating Manual

A48 / A48B (base plate) BATTERY CHARGER

OWNERS MANUAL JANUARY 2007 ISO

INSTALLATION AND OPERATION MANUAL

Operating Manual / / REV F

Installation Instructions and User Manual For

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

DP140e. Installation & Operations Manual

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

POWERWARE User s Guide VA.

OWNERS MANUAL JANUARY 2007 ISO

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Technical Manual. DLM Module. This manual should remain with the unit.

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

IMPORTANT SAFEGUARDS

www. ElectricalPartManuals. com

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Cruising Charger Series OWNER S MANUAL

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Owner s Manual Extended-Run Battery Cabinet

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

INSTRUCTION MANUAL FOR PC63 CAGE

Installation Power Management Unit Battery Cables and Battery Harness

LESTRONIC II BATTERY CHARGER MODEL 19740

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

BATTERY SAVER LOW RIPPLE HO

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

DISCHARGER-ANALYZER BDX USER'S MANUAL

A39 UNIVERSAL SCR CHARGER

Powerware 9390 Integrated Battery Cabinet (Models IBC-S and IBC-L) Installation Manual

AC CONVERTER / BATTERY CHARGER

BATTERY REPLACEMENT GUIDE

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

BRAVER UPS. (Uninterruptible Power System) User s Manual

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Transcription:

Installation, Operation, & Maintenance Manual

Stored Energy Systems Packaged By: 1840 Industrial Circle C&C Power, Inc. Longmont, Co 80501 395 Mission Street www.sens-usa.com Carol Stream, IL 60188 Technical Support: Phone: (303) 678-7500 or (800) 742-2326 Email: service@sens-usa.com SENS, the SENS logo and PowerCab are trademarks of Stored Energy Systems LLC. 8/24/2017 2 755-00129 R04

TABLE OF CONTENTS 1. Important Information About This Manual... 4 1.1 Manual Symbols... 4 2. Introduction... 5 3. Safety Precautions... 6 4. Inspection Upon Receipt of Goods... 8 4.1 General... 8 4.2 Visible Damage... 8 4.3 Concealed Damage... 8 4.4 Return of Damaged Goods... 8 5. System Overview... 9 6. System Specifications... 10 6.1 Batteries... 10 6.2 System Grounding... 10 6.3 AC Input... 10 6.4 DC Output... 10 6.5 Optional AC Output... 11 6.6 Optional LVD... 11 6.7 General Specifications... 11 7. Installation... 13 7.1 Preparation... 13 7.1.1 Equipment Inspection... 13 7.1.2 Necessary Equipment and Tools... 13 7.1.3 Installation Safety Precautions... 13 7.2 Installation Steps... 13 7.2.1 Equipment Location... 13 7.2.2 Equipment Mounting... 14 7.2.3 Equipment Grounding... 14 7.2.4 AC/DC Connections... 14 7.2.5 System Operation... 15 8. System Maintenance... 16 8.1 Battery Replacement... 16 9. Reference Materials... 18 10. Warranty... 23 8/24/2017 3 755-00129 R04

1. IMPORTANT INFORMATION ABOUT THIS MANUAL SAVE THESE INSTRUCTIONS! This manual contains important information that is needed during the installation and maintenance of the system. 1.1 MANUAL SYMBOLS Warning / Caution: Indicates information provided to protect the user against personal injury, safety hazards and/or possible equipment damage. Important: Indicates information provided as an installation or operating instruction or tip as well as general important installation and system information. 8/24/2017 4 755-00129 R04

2. INTRODUCTION Stored Energy Systems (SENS ) would like to thank you for choosing SENS product for your power and back-up equipment needs. We know there are a lot of choices in the industry, and we appreciate the opportunity to supply our customers with the highest quality power products manufactured in the United States. All SENS products are built to the highest industry standards and are Hi Pot tested to UL standards prior to shipment. All standard configurations are C-UL listed. Sales support for existing or future equipment needs are provided by our technical sales staff. For all technical, sales, and service related questions please call our office line at 303-678-7500 and you will be directed to the appropriate individual to answer your questions. After normal working hours please leave a detailed message, with your phone number, on our voice mail system and a qualified representative will contact you as quickly as possible. Stored Energy Systems Packaged By: 1840 Industrial Circle C&C Power, Inc. Longmont, Co 80501 395 Mission Street www.sens-usa.com Carol Stream, IL 60188 Technical and Sales Support: Phone: (303) 678-7500 or (800) 742-2326 Email: service@sens-usa.com 8/24/2017 5 755-00129 R04

3. SAFETY PRECAUTIONS Before installing or maintaining this system, it is extremely important to read this manual and be sure that all system drawings and schematics are reviewed and clearly understood. If there are any questions concerning this manual or any of the installation or maintenance procedures and/or requirements please contact a C&C Power representative before proceeding. When installing this power system, follow all applicable federal, state and local regulations as well as industry guidelines to insure proper system installation. Only qualified electricians or DC power technicians should attempt to install or service this equipment. System installation and maintenance should always be performed with heavily insulated tools. It is also recommended to wear rubber gloves, boots, and use insulating mats to stand on when working on this equipment. Always wear eye protection when installing or maintaining batteries and/or power equipment. Do not attempt to unpack or move the battery cabinet without assistance. Use appropriate handling equipment rated to bear the weight and bulk of the battery cabinet, such as freight elevators, pallet jacks and forklifts. (Fully extend forks under load. Spread forks to maximum possible width under load. Lift cabinet from bottom only. Wear safety shoes.) Do not smoke or present open flames near any battery system. For the safety of others, never leave an open cabinet or panel unattended. To reduce the risk of fire, replace fuses with the same type and rating of fuses supplied with the system. 8/24/2017 6 755-00129 R04

DC Power and Batteries can be very dangerous and have extremely high short circuit current. Electrical shock, severe burns, fire or death can result from a system short. To avoid personal injury including electrical shock, severe burns and possible death, all jewelry including bracelets, rings and watches must be removed prior to installing or servicing this system. Do not open or mutilate batteries. Opened or severely damaged batteries can release toxic electrolyte which is harmful to the skin and eyes. Never lay loose cables, metal parts or tools on top of batteries. Under certain conditions, batteries can vent potentially explosive gas (hydrogen). Never enclose batteries or battery cabinets in a sealed room. 8/24/2017 7 755-00129 R04

4. INSPECTION UPON RECEIPT OF GOODS 4.1 GENERAL Special precautions and care have been taken to ensure the system arrives safe and undamaged. However, upon receipt, you should inspect the entire shipment, including the crate and any boxes for evidence of damage that may have occurred during transit. 4.2 VISIBLE DAMAGE It is the responsibility of the person receiving the shipment to inventory and fully inspect all materials against the bill of lading or weigh bill IMMEDIATELY while the carrier representative is still present. Insure that all items are accounted for, including number of skids and quantity of boxes. Also note any visible external damage that may have occurred during transit. Make all applicable notations on the delivery receipt before signing and file a damage report with the carrier. 4.3 CONCEALED DAMAGE Within 3 to 30 days of receipt (depending on courier), unpack the system and check for any concealed damage. Check the materials received against the detailed packing list to verify the quantity and the condition as complete and satisfactory. Note any damage to the internal packaging, then request an inspection by the carrier and file a concealed damage claim. If there is a material shortage, contact a representative at SENS to file a claim. Please contact your shipping company for all shipping damage. C&C Power is not responsible for any shipping damage. 4.4 RETURN OF DAMAGED GOODS Should equipment be damaged and require return, contact SENS Technical Support. A representative will provide instructions along with an RMA number to expedite the return. A RMA number must be obtained before returning equipment to Sens or C&C Power, Inc. 8/24/2017 8 755-00129 R04

5. SYSTEM OVERVIEW The DC PowerCab 120 is a non-stop DC power system designed to deliver uninterruptible DC power to critical loads. PowerCab includes a DC power supply/charger, storage battery string, and DC distribution to load center. In addition to the charger, battery, distribution panel and cabinet, PowerCab can be optionally equipped with: Additional DC distribution Low voltage disconnect (to prevent battery from over-discharge) Top-Lift Bracket Multiple DC to AC inverter options The DC PowerCab system is fully factory assembled and is ready to install upon delivery. 8/24/2017 9 755-00129 R04

6. SYSTEM SPECIFICATIONS 6.1 BATTERIES Type: Valve Regulated Lead Acid (VRLA), sealed, non-spillable Amp-Hour Options: 100 AH, 150AH, 170AH or 200AH Voltage: 12 VDC Nominal Only cabinets with Flame Retardant Batteries are suitable for computer room use. 6.2 SYSTEM GROUNDING All system ground wires should be derived from the main building ground source. Cabinet Safety Ground: Each cabinet is supplied with a mechanical ground lug that accepts bare wire from #2/0 AWG to #14 AWG. Torque: 375 in-lbs Wire Size and Type: Ground wire should be sized per NEC and/or all applicable national and local codes. 6.3 AC INPUT The AC input to the charger (see Figure 1 for location) can be: 208 VAC 60 Hz, 1ф 230 VAC 50/60 Hz, 1ф 240 VAC 60 Hz, 1ф 115-120/208/230-240 VAC 60 Hz, 1ф 115-120/208/230-240 VAC, 50/60 Hz, 1ф 400 VAC 50/60 Hz, 1ф 480 VAC 60 Hz, 1ф 6.4 DC OUTPUT DC Output Voltage Options include: 24-volt nominal (12 cells lead-acid) 48-volt nominal (24 cells lead-acid) 120-volt nominal (60 cells lead-acid) 240-volt nominal (120 cells lead-acid) Charger Output Current Options include: 6 Amps (15A charger to panelboard breaker) 12 Amps (15A charger to panelboard breaker) 16 Amps (20A charger to panelboard breaker) 25 Amps (35A charger to panelboard breaker) 35 Amps (45A charger to panelboard breaker) 50 Amps (70A charger to panelboard breaker) 8/24/2017 10 755-00129 R04

75 Amps (100A charger to panelboard breaker) 100 Amps (125A charger to accessory breaker) 150 Amps (200A charger to accessory breaker) DC Load Center: Panelboard, 100A, 2-pole battery main breaker, 2-pole charger-feed breaker, plus 12 each 2-pole load breaker positions. Wire Size and Type: Per NEC and/or all applicable national and local codes. 6.5 OPTIONAL AC OUTPUT 600 Watt Inverter, 120VAC, 60Hz 600 Watt Inverter, 230VAC, 50Hz 1000 Watt Inverter, 120VAC, 60Hz 1000 Watt Inverter, 230VAC, 50Hz 1100 Watt Inverter, 120VAC, 60Hz 1100 Watt Inverter, 230VAC, 50Hz 2000 Watt Inverter, 120VAC, 60Hz 2000 Watt Inverter, 230VAC, 50Hz 3000 Watt Inverter, 120VAC, 60Hz 3000 Watt Inverter, 230VAC, 50Hz AC output option consumes one 2-pole load breaker position. Wire Size and Type: Per NEC and/or all applicable national and local codes. Wire should be sized for a maximum voltage drop of 0.5 volt. 6.6 OPTIONAL LVD When AC power fails, the systems batteries will discharge in order to provide the necessary backup power to the load. If the DC PowerCab 120 is equipped with the Low Voltage Disconnect (LVD) feature, the system load will be automatically disconnected at the customer adjustable LVD disconnect voltage setting. This will prevent the batteries from being discharged to unsafe levels. A Bender VME420 type Digital Voltage Monitor Relay is used to control the contactor in the LVD circuit. The LVD circuit, with the Monitor Relay imbedded, wiring connections to the DC load center and the Charger is shown in Figure 2/Section 9. The activation and factory settings of the LVD Voltage Relay are shown in Figure 3/Section 9 for a 120 VDC system, Figure 4/Section 9 for a 48 VDC system and Figure 5/Section 9 for a 24 VDC system. 6.7 GENERAL SPECIFICATIONS Cabinet Size: 30.5 W x 31.5 D x 78.7 H Typical Weights: Empty Cabinet (approximately): 450 lbs Complete System Weight can be found on the individual cabinet drawing that is mounted to the inside of the door. 8/24/2017 11 755-00129 R04

Operating Temperature: 20 C to 25 C (68 F to 77 F) recommended for optimum battery performance. Ventilation: Ventilation holes located in the front, rear, and top of the cabinet. Clearance around the equipment should be as suggested by NEC and/or all applicable national and local codes. The battery cabinet does not require rear access or rear clearance. Under certain conditions, batteries can vent potentially explosive gas (hydrogen). Never enclose batteries or battery cabinets in a sealed room. Batteries should be stored no longer than three months at 25 C (77 F) or lower before recharging. Exceeding the recommended ambient storage temperature may cause damage to the batteries. 8/24/2017 12 755-00129 R04

7. INSTALLATION 7.1 PREPARATION 7.1.1 EQUIPMENT INSPECTION Remove the equipment from the packaging material and inspect for any shipping damage that may have been overlooked upon receipt of goods. Verify that the system includes all necessary hardware for installation. 7.1.2 NECESSARY EQUIPMENT AND TOOLS o Heavily insulated assortment of hand tools o Digital voltmeter 7.1.3 INSTALLATION SAFETY PRECAUTIONS Before proceeding with system installation, be sure to review and understand all of the SAFETY PRECAUTIONS in this manual! DC VOLTAGE WARNING! Hazardous DC voltages are present in the system. This hazard will always be present in a battery system including when it is offline. Accidental short circuit of the positive and negative terminal will cause tremendous currents to flow resulting in electrical shock, severe burns, fire and possible death! Use extreme caution when installing and maintaining the system! 7.2 INSTALLATION STEPS Before installing or maintaining this system, it is extremely important to read this manual and be sure that all system drawings and schematics are reviewed and clearly understood. If there are any questions concerning this manual or any of the installation or maintenance procedures and/or requirements please contact a C&C Power representative before proceeding. 7.2.1 EQUIPMENT LOCATION Prior to installation, verify floor loading requirements (see weights in Section 6.7) and all applicable codes pertaining to the related equipment. Environmental conditions should also be reviewed. Battery systems require an area with proper ventilation and cooling. An ambient temperature between 20 C to 25 C (68 F to 77 F) is recommended for optimum battery life and performance. Clearance around the equipment should be as suggested by NEC and/or all applicable national and local codes. The battery cabinet does not require rear access or rear clearance. Under certain conditions, batteries can vent potentially explosive gas (hydrogen). Never enclose batteries or battery cabinets in a sealed room. Follow international (IFC 608), state, and local codes for ventilation requirements. 8/24/2017 13 755-00129 R04

7.2.2 EQUIPMENT MOUNTING Do not attempt to unpack or move the battery cabinet without assistance. Use appropriate handling equipment rated to bear the weight and bulk of the battery cabinet, such as freight elevators, pallet jacks and forklifts. (Fully extend forks under load. Spread forks to maximum possible width under load. Lift cabinet from bottom only. Wear safety shoes.) 1. The SENS DC PowerCab 120 cabinet is equipped with pallet jack and/or forklift access openings in the front and rear of the cabinet. Move the equipment into the desired location and set into place. 2. With the cabinet in the desired location, mark the location of four mounting holes found at the bottom of the cabinet legs. Two sets of mount holes are provided so that mount hardware can be offset in multi cabinet installations. 3. Move the cabinet out of the way and drill holes for the mounting hardware that will be used. 4. Move the cabinet back into place, align the holes, and tighten the hardware. 5. Should any drilling be performed on this equipment, make sure all exposed batteries and connections are completely covered using insulated type mats. 7.2.3 EQUIPMENT GROUNDING All system ground wires should be derived from the main building ground source. For multi cabinet systems, each cabinet needs to have a designated cabinet ground wire derived from the main building ground source. Terminate a cabinet ground wire from the main building ground source to the supplied #2/0 AWG - #14AWG mechanical lug located on the bottom panel of the cabinet in the front right-hand corner. Wire should be sized per NEC and/or all applicable national and local codes. 7.2.4 AC/DC CONNECTIONS Review the attached to the cabinet System Drawings and Schematics for model specific information on DC output connections to the panelboard. Wire should be sized for a maximum voltage drop of 0.5 volt. Verify that the Battery Main Breaker and the Charger Main Breaker on the panelboard (see System Drawing/Schematic) are in the off/open position before making any DC connections from the panelboard breakers to their respective loads. 8/24/2017 14 755-00129 R04

Open the front doors on the cabinet and check for any noticeable problems or damage that may have occurred during shipment. 1. Review the attached system drawing/schematic located inside the cabinet doors to find the location of the jumper that has been left off in the middle of the battery string for added safety during installation and shipping. This jumper will be installed later. 2. Check and re-torque all internal battery connections, as shipping may have caused these connections to come loose. Proper torque values are noted on the system schematic/drawing and can also be found on most battery cases. 3. Refer to the Charger Operation Installation and Operation Manual for instructions for making AC power connections to the charger. The AC input cables can ingress the cabinet from either the top panel or the bottom panel by removing the appropriate panel knockout plate. The AC input cables should be run in the wire ducts located on the left-side of the cabinet from the cabinet ingress point to the connection point on the charger. 4. Without LVD Option: Verify that the battery string output and the charger DC output are connected to the breakers on the panelboard specified in the system schematic/drawing. Assure that these two breakers are in the off/open position before making any DC connections from the panelboard breakers to their respective loads. With LVD Option: Referencing Figure 2/ Section 9, verify that the battery string output and the charger DC output are connected as shown to the LVD circuit and the LVD circuit is terminated to the proper breaker in the DC Load Center. 5. Review the supplied cabinet schematic/drawing for information on the size and location of the DC distribution breakers on the panelboard. Route the DC output cables from the breakers through the wire duct located on the right-side of the cabinet to the cabinet egress point on the top of the cabinet (after removing the knockout plate) and connect to their respective loads. All cables should be sized per NEC and any other local codes pertaining to this equipment. 6. Connect the jumper that was left off during shipment and install as shown on the system schematic. Torque connections properly. 7.2.5 SYSTEM OPERATION Please refer to the Charger Operation Installation and Operation Manual included with the SENS DC PowerCab 120 product for startup and operation information for the charger unit. 8/24/2017 15 755-00129 R04

8. SYSTEM MAINTENANCE Before proceeding with system maintenance, be sure to review and understand all of the SAFETY PRECAUTIONS in this manual! Verify that the Battery Main breaker on the panelboard and Charger AC Main breaker (on the charger unit) are in the off/open position before servicing the system. 8.1 BATTERY REPLACEMENT When batteries are replaced they must be properly installed paying special attention to terminal polarity orientation! If wired incorrectly it will cause a short in the system and can result in electrical shock, severe burns, fire and possible death! Be sure to review the system schematics before terminating any battery cables. Caution: Risk of explosion if batteries are replaced by an incorrect type. Do not dispose of batteries in a fire. The batteries may explode. Contact your local hazardous waste or recycling center for battery disposal requirements. Do not discard batteries in the trash. This product contains sealed lead acid batteries. Contact your local hazardous waste or recycling center for battery disposal requirements. 1. Prepare the new battery for installation. Verify that the battery is the same type and amp-hour rating as the batteries that are in the system. 2. Using a digital voltmeter, measure the battery voltage to verify that it is 12.4 VDC or above. 3. Use a brass wire brush or abrasive pad to polish the battery terminals. 4. Apply no-ox type terminal grease to the battery terminals to avoid corrosion. 5. Disconnect the loads from the battery string by turning off/opening the Battery Main circuit breaker on the panelboard. 6. Remove the center jumper on the battery string to reduce the voltage. If replacing all batteries, continue reducing the voltage by removing the inter-shelf jumper. 7. Disconnect the cables from the battery to be replaced. 8. Remove the bad battery. 8/24/2017 16 755-00129 R04

9. Put the new battery into place. Make sure new battery is installed properly regarding polarity orientation. Use the supplied wiring schematic/ drawing found inside the battery cabinet door to verify the cabinet wiring. 10. Reconnect the cables to battery and make sure the connections are properly torqued. 11. Reconnect any removed string jumpers and make sure the connections are properly torqued. 12. Check the battery string voltage at input side of the Battery Main circuit breaker. 13. Start the charger and reconnect the loads to the battery string by turning on/closing the circuit breakers turned off in step 5. 8/24/2017 17 755-00129 R04

9. REFERENCE MATERIALS Figure 1 8/24/2017 18 755-00129 R04

Figure 2 8/24/2017 19 755-00129 R04

SENS DC PowerCab LVD Voltage Relay Settings - 120 VDC Systems Bender VME420-D-2 (043-00009) The settings for the LVD Voltage Relay are listed in the table below: Activation Menu Sub Menu Menu Item Adjustable parameter & Setting AL (response - values) out (output control) t (timing check) Set (device control) -------> <U ON (105V) Undervoltage >U OFF Overvoltage U Hys 14% Hysteresis < U / > U < Hz OFF Underfrequency > Hz OFF Overfrequency Hz Hys N/A Hysteresis, frequency -------> M OFF Fault memory 1 N.C. Operating mode K1 2 N.C. Operating mode K2 LEd OFF LED s Signal relay in alarm state r1 (K1: (assignment alarm category) r2 (K2: (assignment alarm category) 1 Err OFF Device error at K1 r1 < U ON Undervoltage K1 r1 > U OFF Overvoltage K1 r1 < Hz OFF Underfrequency K1 r1 > Hz OFF Overfrequency K1 1 S.AL OFF Start with alarm during (t+t) on1 2 Err OFF Device error K2 r2 < U ON Undervoltage K2 r2 > U OFF Overvoltage K2 r2 < Hz OFF Underfrequency K2 r2 > Hz OFF Overfrequency K2 2 S.AL OFF Start with alarm during (t+t) on2 -------> t on 1 0 Response delay K1 -------> t on 2 0 Response delay K2 T 0 Starting delay t off 0 Delay on release K1/K2 OFF Parameter setting via password FAC - Re-establish factory settings PrE - Manual preset SYS - Function blocked InF ---------------> - Display hard/ software version HiS -------> Clr - History memory for the first alarm value, erasable Figure 3 8/24/2017 20 755-00129 R04

SENS DC PowerCab LVD Voltage Relay Settings - 48 VDC Systems Bender VME420-D-1 (043-00011) The settings for the LVD Voltage Relay are listed in the table below: Activation Menu Sub Menu Menu Item Adjustable parameter & Setting AL (response - values) out (output control) t (timing check) Set (device control) -------> <U ON (42V) Undervoltage >U OFF Overvoltage U Hys 17% Hysteresis < U / > U < Hz OFF Underfrequency > Hz OFF Overfrequency Hz Hys N/A Hysteresis, frequency -------> M OFF Fault memory 1 N.C. Operating mode K1 2 N.C. Operating mode K2 LEd OFF LED s Signal relay in alarm state r1 (K1: (assignment alarm category) 1 Err OFF Device error at K1 r1 < U ON Undervoltage K1 r1 > U OFF Overvoltage K1 r1 < Hz OFF Underfrequency K1 r1 > Hz OFF Overfrequency K1 1 S.AL OFF Start with alarm during (t+t) on1 2 Err OFF Device error K2 r2 < U ON Undervoltage K2 r2 > U OFF Overvoltage K2 r2 < Hz OFF Underfrequency K2 r2 > Hz OFF Overfrequency K2 2 S.AL OFF Start with alarm during (t+t) on2 -------> t on 1 0 Response delay K1 -------> t on 2 0 Response delay K2 T 0 Starting delay t off 0 Delay on release K1/K2 OFF Parameter setting via password FAC - Re-establish factory settings PrE - Manual preset SYS - Function blocked InF ---------------> - Display hard/ software version HiS -------> Clr - History memory for the first alarm value, erasable Figure 4 8/24/2017 21 755-00129 R04

SENS DC PowerCab LVD Voltage Relay Settings - 24 VDC Systems Bender VME420-D-1 (043-00011) The settings for the LVD Voltage Relay are listed in the table below: Activation Menu Sub Menu Menu Item Adjustable parameter & Setting AL (response - values) out (output control) t (timing check) Set (device control) -------> <U ON (21V) Undervoltage >U OFF Overvoltage U Hys 14% Hysteresis < U / > U < Hz OFF Underfrequency > Hz OFF Overfrequency Hz Hys N/A Hysteresis, frequency -------> M OFF Fault memory 1 N.C. Operating mode K1 2 N.C. Operating mode K2 LEd OFF LED s Signal relay in alarm state r1 (K1: (assignment alarm category) r2 (K2: (assignment alarm category) 1 Err OFF Device error at K1 r1 < U ON Undervoltage K1 r1 > U OFF Overvoltage K1 r1 < Hz OFF Underfrequency K1 r1 > Hz OFF Overfrequency K1 1 S.AL OFF Start with alarm during (t+t) on1 2 Err OFF Device error K2 r2 < U ON Undervoltage K2 r2 > U OFF Overvoltage K2 r2 < Hz OFF Underfrequency K2 r2 > Hz OFF Overfrequency K2 2 S.AL OFF Start with alarm during (t+t) on2 -------> t on 1 0 Response delay K1 -------> t on 2 0 Response delay K2 T 0 Starting delay t off 0 Delay on release K1/K2 OFF Parameter setting via password FAC - Re-establish factory settings PrE - Manual preset SYS - Function blocked InF ---------------> - Display hard/ software version HiS -------> Clr - History memory for the first alarm value, erasable Figure 5 8/24/2017 22 755-00129 R04

10. WARRANTY For warranty information, please go to www.sens-usa.com/warrantyrepair/ 8/24/2017 23 755-00129 R04