Product Data. 38TZA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 AVAILABLE OPTIONS

Similar documents
556A (60 Hz) QUANTUM PLUS 14 SEER AIR CONDITIONER WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 556A.24.5

Product Data. 38 TDB (60 Hz) WeatherMaker Two-Speed Electric Air Conditioner with Puron. Sizes 024, 036, 037, 048, and 060 FEATURES/BENEFITS

Product Data. Infinity 18 38TDB (60 Hz) Two-Speed Air Conditioner with Puron Refrigerant. Sizes 024, 036, 037, 048, and 060 FEATURES/BENEFITS

698B (60 HZ) Sizes 024, 036, 048, and 060

556A (60 Hz) DELUXE 14 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 042. Form No. PDS 556A.24.4 AVAILABLE OPTIONS

537G Sizes 024 thru 060

598B TWO-SPEED AIR CONDITIONER WITH PURON REFRIGERANT. Sizes 024, 036, 048, and 060. Form No. PDS 598B.24.7

Product Data. Infinity YDB (60 Hz) Two-Speed Heat Pump with Puron Refrigerant. Sizes 024, 036, 037, 048, and 060

N2AE - 50 Hz PRODUCT SPECIFICATIONS

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38TRA (60 Hz) Air Conditioner. Sizes 018 thru 060

Product Data. Efficiency. S 14 SEER/11 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

Product Data. Efficiency S S S Sound S S Comfort S. S S S S S S S S Durability A WeatherArmort protection package:

Product Data PA16NA FEATURES AND BENEFITS. 16 SEER Split System Air Conditioner with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH15NB. 15SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

TSA6. Product Specifications. SmartComfort TXC 5600

N4A4 C. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS CA13NA SINGLE -STAGE AIR CONDITIONER WITH PURON REFRIGERANT. Efficiency S S S Reliability S

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

N4A6. Product Specifications

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

Product Data EFFICIENCY. S SEER/11-12 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available SOUND

Product Data. Efficiency

Product Data. 38YCB 50 Hz Heat Pump. 38YCB Sizes 024 thru 060 FEATURES/BENEFITS

Product Data PH13NB PH13PB FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data EFFICIENCY. S SEER/11-12 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available SOUND

CSA6. Product Specifications. SoftSound SXC 2600

Product Data. 38HDR Performance Series Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency S S S Sound S S Comfort S. S S S S S S Durability. WeatherArmort protection package:

HSH5. Product Specifications. Quiet Comfort DXC 1500

Product Data. Efficiency

Product Data. 24ANB6 Infinityr Air Conditioner with Puronr Refrigerant 1---1/2 to 5 Nominal Tons (Size ) INDUSTRY LEADING FEATURES / BENEFITS

Product Data PH13NB PH13PB FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons

R4H4. Product Specifications

Product Data. Efficiency S S S Sound S S Comfort S. S S S S S S Durability. DuraGuardt protection package:

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability. WeatherArmort protection package:

Product Data. 38HDR Performance Series Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. S Two -stage reciprocating compressor S Field -installed 16 cu. in. filter drier S Back -seating service valves S High -pressure switch

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABC6 Baset16 Air Conditioner with Puronr Refrigerant 1---1/2 Through 5 Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANB7 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

HCH6. Product Specifications

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Product Data. Efficiency S

WCA4**4. Product Specifications

Nominal Btu/hr. Min. Circuit Ampacity x 35 x 35 3½ 42, , x 35 x , , x 35 x ,000

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 187B (2-5 Ton) 180B (3 Ton Trophy) EVOLUTIONt 17 AIR CONDITIONER WITH PURONr REFRIGERANT

Product Data. S Scroll compressor S Field -installed 16 cu. in. filter drier S Back -seating service valves S High -pressure switch

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability. WeatherArmort protection package:

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. S Up to 19 SEER / up to 12.5 EER S Microtube Technologyt refrigeration system Sound

Product Data. Efficiency S. S S Sound S Comfort S. S S S S S S S S Durability. WeatherArmort protection package:

Product Data. 38QRR Performancet Series Heat Pump with PURONr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ANB7 Infinityt Stage Air Conditioner with Puronr Refrigerant 2to5NominalTons

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Product Data. Efficiency

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

Product Data. CA16NA Baset Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S S

ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz. Min. Circuit Ampacity

697C (60 HZ) SPLIT-SYSTEM HEAT PUMP UNITS. Sizes 018 thru 060. Form No. PDS 697C.18.1P FEATURES

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

N2H3**C. Product Specifications EFFICIENT 13 SEER HEAT PUMP. Performance Series

Product Data. 24ABR3 BasetSeries 13 Air Conditioner Sizes 18 to /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability. DuraGuardt protection package: Warranty Single-Phase.

Product Data. 24ABA4 BasetSeries 14 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Product Data. S Up to 19 SEER / 13 EER S Microtube Technologyt refrigeration system Sound

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

RCD Air Cooled Condensing Unit (50/60 Hz)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

Product Data. 25HBA4 BasetSeries 14 Heat Pump with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

Product Data. S Up to 19 SEER / up to 13 EER S Microtube Technologyt refrigeration system Sound

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S S S Durability A WeatherArmort protection package: Warranty Single-Phase

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. Features/Benefits. 38HDL Cooling Only Condensing Unit. 1 1 / 2 to 5 Nominal Tons

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved

CONDENSING UNITS RAKB- SERIES. Seven Models

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

Transcription:

Product Data 38TZA (60 Hz) Air Conditioner with Puron Refrigerant Sizes 018 thru 060 Carrier s WeatherMaker 38TZA with Puron refrigerant provides a completely unique collection of features which cannot be matched by any other family of equipment. The 38TZA family has been designed as the first air conditioning system utilizing Carrier s unique Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth s ozone layer. Carrier s WeatherMaker systems with Puron refrigerant meet the Energy Star guidelines for energy efficiency. AVAILABLE OPTIONS WeatherArmor III System The casing steel is galvanized and coated with a layer of zinc phosphate. A modified polyester powder coating is then applied and baked on, providing each unit with a hard, smooth finish that will last for many years. All screws on the cabinet exterior are SermaGuard coated for a long lasting, rust-resistant, quality appearance. The coil is protected by an enhanced WeatherArmor heavy duty inlet grille. Constructed of a coated 12 gage steel wire grid and with spacing of 3/8 in., the guard helps to protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. Puron Environmentally Friendly Refrigerant Is Carrier s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that is damaging to the ozone layer. The most important advantage of Puron refrigerant is that it has not been banned in future air conditioning systems as the traditional refrigerant, R-22, has been. Puron refrigerant is in service in thousands of systems providing highly reliable, environmentally sound performance. For specific R-22 phase out information see your Carrier distributor. High Efficiency Performance Is delivered through a combination of features including Carrier s Puron refrigerant, unique scroll compressor, and advanced heat transfer surfaces. Efficiency ratings are 12 SEER (Seasonal Energy Copyright 2003 Carrier Corporation Form 38TZA-5PD

Efficiency Ratio) with enhanced ratings of up to 14 SEER. Sophisticated heat transfer surfaces utilized in Carrier s 38TZA design allow heat to easily be transferred to the outdoor air and requires less energy. The unique scroll compressor found in the 38TZA design performs quietly and adds to the overall efficiency of the system. For improved serviceability, all models are equipped with a compressor terminal plug. Finally, Carrier s Puron refrigerant operates more efficiently than ordinary R-22 refrigerant found in other systems. The efficiency levels provided by the 38TZA provide end users with lower costs of operation than traditional air conditioning systems. Assured Future Service By utilizing the environmentally sound refrigerant, Puron, 38TZA models will remain serviceable well into the future. The Clean Air Act of 1990 has placed a cap on production of most other refrigerants which has scheduled reductions beginning in 2004. The resulting cap in production ultimately results in a complete ban on many other refrigerants in new equipment by the year 2010. These changes, required by federal law, mean the supply of other refrigerants may be limited in the near future making Puron the correct choice when considering long term serviceability. Highly Reliable Performance Is delivered through the superior design of the system and componentry. The reliability of models with Puron refrigerant have been proven to provide the lowest incidence of warranty service of any product in the Carrier family in its last 3 years of service. Long term reliability is assured through the use of both high and low pressure switches which will not allow the system to operate in the event of a significant change in operating pressure. In doing this, the system is protected from damage if an unusual condition arises. Finally, Carrier includes a special liquid line filter drier designed to trap moisture and contaminants which could otherwise shorten the life of the system. Carrier s Silencer System Is one of the most sought after features of the 38TZA family. Extremely low operating sound is the result of special attention to the air moving through the outdoor unit, a specially designed sound enclosure surrounding the compressor, and an unique laminated plate beneath the compressor to eliminate sound transmission to the rest of the system. Application Versatility Carrier s systems utilizing Puron refrigerant have the same application guidelines as other systems. Applications which include long line sets (50 to 175 ft) or applications which require the system to operate at low outdoor temperatures (below 55 F, 12.8 C) are approved under Carrier s standard guidelines. Carrier Coils and Fan Coils to Complete the System Carrier specially designs both the outdoor product and indoor coil products to operate with assured reliability and performance. A wide range of indoor coil options are listed in the ratings section of this publication. Special Protective Devices High and low pressure switches and internal protection in the compressor including temperature and current sensing overloads prevent operation under potentially damaging circumstances. A special liquid line filter drier designed to trap nearly 4 times the volume of contaminants of standard driers provides superior protection from moisture trapped in the system. Electrical Range 208/230v, single phase. Wide Range of Sizes Available in seven sizes: 1-1/2, 2, 2-1/2, 3, 3-1/2, 4, and 5 tons. Totally Enclosed Fan Motor Protected from adverse weather conditions. Unit Design Enhanced copper and aluminum heat transfer surfaces with vertical air discharge to direct air up and away from the area. External Service Valves Both service valves are back seating type valves which are externally located. These unique valves allow service technicians to evacuate or charge the system in less time than standard service valves. Easy Serviceability Easy removal panels provide access to both electrical and refrigerant carrying components simplifying installation and service. Agency Approvals 38TZA models are listed with UL (U.S. and Canada), ARI, and CEC. Special endorsements have also been awarded these products by Energy Star which recognizes energy efficient products. Limited Warranty A standard five year warranty on parts with 10 years on the compressor. Optional warranties are available through your Carrier distributor. * As an ENERGY STAR partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency. ARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 REGISTERED QUALITY SYSTEM CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. * Only those system combinations that meet Energy Star efficiency requirements. Refer to the combination ratings in the product data digest. Model number nomenclature 38TZA 024 3 0 1 Deluxe 12 SEER Split-System Air Conditioner Nominal Capacity 018 18,000 Btuh 042 42,000 Btuh 024 24,000 Btuh 048 48,000 Btuh 030 30,000 Btuh 060 60,000 Btuh 036 36,000 Btuh 2 Electrical 3 208/230-1 Series Packaging

Physical data SIZE-SERIES 018-32, 33 024-32, 33 030-32, 33 036-32, 33/34 042-32, 33 048-32, 33 060-32, 33 Operating Weight (Lb) 168 220 218 221 224 226 284 COMPRESSOR Manufacturer Copeland Type Scroll/Scroll Tech REFRIGERANT Puron Control AccuRater (with Ring) Charge (Lb) 5.22 5.31 5.19 5.43 5.43 5.75 8.00 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM) 1700 1800 2400 2400 2800 2800 3300 Motor HP 1/12 1/5 1/8 1/8 1/5 1/5 1/4 Motor RPM 1100 825 825 825 825 825 1100 COND COIL Copper Tube, Aluminum Plate Fin Face Area (Sq ft) 10.9 12.2 12.2 12.2 12.2 12.2 18.2 Fins per In. 25 25 25 25 25 25 25 Rows 1 1 1 1 1 1 1 Circuits 2 2 2 2 2 2 3 VALVE CONNECT. (In. ID) Sweat Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Vapor (0 50 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1-1/8 Vapor (Max Diameter for Long- Line Applications) 3/4 3/4 7/8 7/8 1-1/8 1-1/8 1-1/8 Liquid (0 50 Ft Tube Length) 3/8 Liquid (For Long-Line Applications) 3/8 * For tubing sets greater than 50 ft and/or 20 ft vertical differential, consult Application Guideline and Service Manual Air Conditioners and Heat Pumps Using Puron Refrigerant. NOTE: See unit Installation Instructions for proper installation. SIZE-SERIES ACCURATER PISTON CHART PISTON* IDENTIFICATION NO. 018-32, 33 49 024-32, 33 61 030-32, 33 63 036-32, 33, 34 042-32, 33 76 048-32, 33 80 060-32, 33 90 * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*) SIZE-SERIES REQUIRED SUBCOOLING ( F) 018-32, 33 10 024-32, 33 8 030-32, 33 11 036-32, 33, 34 11 042-32, 33 9 048-32, 33 10 060-32, 33 11 * Must be a Puron refrigerant (R-410A) approved hard shutoff TXV. 3

Accessories ORDERING NO. DESCRIPTION KAATD0101TDR Time-Delay Relay All Sizes KSALA0301410 Low-Ambient Pressure Switch All Sizes 32LT660004* (RCD) MotorMaster Control All Sizes KAAFT0101AAA Evaporator Freeze Thermostat All Sizes KAAWS0101AAA Winter Start Control All Sizes KSACY0101AAA Cycle Protector All Sizes KSAHS1501AAA Start Assist Capacitor and Relay Sizes 018 048 KSAHS1601AAA Start Assist Capacitor and Relay Size 060 KAACS0201PTC Start Assist PTC All Sizes KAACH1201AAA Crankcase Heater Sizes 024 060 KSATX0201HSZ Thermostatic Expansion Valve (Hard Shutoff) Sizes 018, 030 KSATX0301HSZ Thermostatic Expansion Valve (Hard Shutoff) Sizes 036, 042 KSATX0401HSZ Thermostatic Expansion Valve (Hard Shutoff) Size 048 KSATX0501HSZ Thermostatic Expansion Valve (Hard Shutoff) Size 060 KSAPX0101PIS Piston Body All Sizes HC34GE232 Ball Bearing Fan Motor Size 018 HC38GE231 (RCD) Ball Bearing Fan Motor Sizes 024 048 HC40GE232 (RCD) Ball Bearing Fan Motor Size 060 KH45LG140 (RCD) Filter Drier (Suction Line) Sizes 018 036 KH45LG141 (RCD) Filter Drier (Suction Line) Sizes 042 060 KAALS0201LLS Liquid-Line Solenoid Valve Sizes 018 060 KSASF0101AAA Support Feet All Sizes KAACF0701SML Coastal Filter Size 018 KAACF0801MED Coastal Filter Sizes 024 060 * Fan motor with ball bearings required. See low-ambient controller Installation Instructions for application. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve. THERMOSTAT/SUBBASE PKG TSTATCCNAC01-B TSTATCCPAC01-B TSTATCCPRH01-B TSTATCCBAC01-B TSTATXXSEN01-B TSTATXXNBP01 TSTATXXPBP01 TSTATXXBBP01 TSTATXXCNV10 DESCRIPTION Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool Thermidistat Control Non-Programmable/Programmable Thermostat with Humidity Control Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1 Stage Heat, 1-Stage Cool Outdoor Air Temperature Sensor Backplate for Non-Programmable Thermostat Backplate for Programmable Thermostat Backplate for Builder s Thermostat Thermostat Conversion Kit (4 to 5 wire) 10 Pack usage guideline ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Control or Low-Ambient Pressure Switch Yes No No Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline No Ball Bearing Fan Motor Yes No No * For Tubing line sets greater than 50 ft and/or 20 ft vertical differential, refer to Application Guideline and Service Manual Air Conditioners and Heat Pumps Using Puron Refrigerant. Only when low-pressure switch is used. Required for low-ambient controller (full modulation feature) and MotorMaster Control only. 4

description and usage (Listed alphabetically) 1. Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster Control has been added. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from corrosive atmosphere without restricting airflow. SUGGESTED USE: In geographic areas where salt damage could occur. In areas with high pollution levels. 3. Compressor Start Assist Capacitor and Relay Start capacitor and start relay which gives hard boost to compressor motor at each start-up. SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft. Installations where outdoor design temperature exceeds 105 F (40.6 C). Installations where Liquid-Line Solenoid Valve or hard shutoff TXV has been added. 4. Compressor Start Assist PTC Solid-state electrical device which gives a soft boost to compressor at each start-up. SUGGESTED USE: Installations with marginal power supply. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control. SUGGESTED USE: When interconnecting tube length exceeds 50 ft. When unit will be operated below 55 F (12.8 C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. SUGGESTED USE: Installations in areas where power interruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 7. Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions. SUGGESTED USE: All units where Winter Start Control has been added. 8. Filter Drier (Suction Line) A device for removing contaminants from refrigerant circulating in an air conditioner: 1 direction flow. NOTE: Must be removed in 72 hrs. SUGGESTED USE: All split-system air conditioners. 9. Liquid-Line Solenoid Valve (LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE: Compressor Start Assist Capacitor and Relay must also be used. Do not use with hard shutoff TXV. SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units Refer to ARI Unitary Directory. In certain long-line applications. Refer to Residential Split System Application Guideline and Service Manual. 10. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F when properly installed. SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). 11. MotorMaster Control A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 5.6 C). SUGGESTED USE: operation at outdoor temperatures below 55 F (12.8 C). All commercial installations. 12. Outdoor Air Temperature Sensor A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat. SUGGESTED USE: All corporate programmable thermostats. 13. Piston Body This piston body is to be used as a replacement for the FK4C Fan Coil R-22 thermostatic expansion valve when used with Puron (R-410A) air conditioner units. Use piston and piston ring shipped with outdoor unit for installations under 50 ft. SUGGESTED USE: All Puron (R-410A) air conditioner installations matched with FK4C Fan Coils. 14. Support Feet Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base minimizing corrosion. SUGGESTED USE: For improved sound ratings. Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. 15. Thermostatic Expansion Valve (TXV) Kit A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shutoff type valves are available. TXV or Liquid Line Solenoid Valve (LSV) is required for use in Long Line Applications see Long Line Application Guideline. NOTE: Compressor Start Assist Capacitor and Relay must also be used. Do not use with Liquid-Line Solenoid Valve. SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 16. Time-Delay Relay An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems. 17. Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions. SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added. 5

Electrical data SIZE- SERIES 018 V/PH OPER VOLTS* COMPR Max Min LRA RLA FAN FLA MCA * Permissible limits of the voltage range at which unit will operate satisfactorily. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 1 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse. FLA Full Load Amps LRA Locked Rotor Arms MCA Minimum Circuit Amps RLA Rated Load Amps NOTE: Control circuit is 24-v on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/ compressors contain internal overload protection. 60 C MIN WIRE SIZE 75 C MIN WIRE SIZE 60 C MAX LENGTH (Ft) 75 C MAX LENGTH (Ft) MAX FUSE** OR CKT BKR AMPS 51.0 10.3 0.5 13.4 14 14 61 58 20 024-32, 33 61.0 13.5 0.5 17.4 14 14 45 43 25 030-32, 33 72.5 14.7 0.8 19.2 14 14 41 39 30 036-32, 34 83.0 15.4 0.8 20.1 12 12 62 59 30 208/230/1 253 187 036-33 87.5 16.7 0.8 21.7 12 12 57 54 30 042-32, 33 105.0 18.6 1.1 24.4 10 10 81 77 40 048-32, 33 109.0 20.5 1.1 26.7 10 10 74 71 40 060-32, 33 158.0 27.6 1.4 35.9 8 8 86 82 60 Sound power (dba) SOUND OCTAVE BAND CENTER FREQUENCY (Hz) SIZE LEVEL (dba) 125 250 500 1000 2000 4000 8000 018 72 66.0 68.5 68.5 66.5 62.0 55.0 49.0 024 69 54 59.5 63 61.5 59 56 48.5 030 70 54 62 63.5 65 62 58.5 51 036 72 54.5 65 64.5 66 63 60.5 52 042 72 56 64 65.5 66.5 64.5 60.5 53 048 76 61 72.5 68.5 64 61 53 060 78 61.5 69.5 71 71.5 69 66 59.5 6

Dimensions NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F (unless low ambient control is used) max 125 F. 3. Series designation is the 13th position of the unit model number. 4. Center of gravity. AIR DISCHARGE L AIR IN H DIA VAPOR LINE CONN FIELD POWER SUPPLY CONN 7/8 IN. DIA HOLE WITH 1 1/8 IN. DIA KNOCKOUT C AND 3/8 IN. DIA TIEDOWN AIR DISCHARGE 2 1/2" 1 3/8 IN. DIA KNOCKOUT KNOCKOUTS (2) PLACES IN BASEPAN 1 9/16" B AIR IN C L D E K FIELD CONTROL SUPPLY CONN 7/8 IN. DIA HOLE 3/8 IN. DIA. LIQUID LINE CONN 10 1/2" F G A ACCESS PANEL M 4 3/16" AIR DISCHARGE AIR IN J 1 3/4" 1 1/4" N A97084 DIMENSIONS (IN.) SIZE SERIES DIMENSIONS MINIMUM MOUNTING PAD A B C D E F G H J K L M N DIMENSIONS 018 32, 33 33-13/16 22-1/2 27-1/2 2-13/16 6-15/16 21-1/2 27-7/8 5/8 8-3/16 12-1/2 14 15-1/2 2-3/8 20 x 27 024 32, 33 27-13/16 30 34-15/16 4 9-3/4 15-1/2 21-7/8 5/8 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32 030 32, 33 27-13/16 30 34-15/16 4 9-3/4 15-1/2 21-7/8 3/4 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32 036 32, 33, 34 27-13/16 30 34-15/16 4 9-3/4 15-1/2 21-7/8 3/4 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32 042 32, 33 27-13/16 30 34-15/16 4 9-3/4 15-1/2 21-7/8 7/8 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32 048 32, 33 27-13/16 30 34-15/16 4 9-3/4 15-1/2 21-7/8 7/8 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32 060 32, 33 39-13/16 30 34-15/16 4 9-3/4 27-1/2 33-7/8 7/8 8-3/16 17-3/4 19 17-3/4 2-15/16 26 x 32 7

Combination ratings See notes on pg. 16. 8 SIZE-SERIES 018-32, 33 024-32, 33 INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV CK5A/CK5BA024* 17,500 NONE 12.00 12.00 10.80 CC5A/CD5AA018 17,200 NONE 11.50 11.50 10.45 CC5A/CD5AA024 17,500 NONE 12.00 12.00 10.70 CC5A/CD5AW024 17,500 NONE 12.00 12.00 10.70 CE3AA024 17,500 NONE 12.00 12.00 10.75 CF5AA024 17,500 NONE 12.00 12.00 10.75 CK3BA024 17,500 NONE 12.00 12.00 10.80 CK5A/CK5BA018 17,200 NONE 11.50 11.50 10.60 CK5A/CK5BW024 17,500 NONE 12.00 12.00 10.80 F(A,B)4(A,B)N(F,C)018 17,200 TDR 11.70 10.60 F(A,B)4(A,B)N(F,C)024 17,500 TDR 12.00 10.90 FC4(B,C)NF024 17,600 TDR&TXV 12.00 10.90 FF1DNA018 17,200 TDR 12.00 10.90 FF1DNA024 17,500 TDR 12.00 10.75 FG3AAA024 17,500 NONE 11.70 11.70 10.60 FK4(C,D)NF001 17,600 TDR&TXV 13.00 12.20 FK4(C,D)NF002 18,000 TDR&TXV 13.50 12.25 FV4(A,B)NF002 18,000 TDR&TXV 13.50 12.25 FX4(A,B)NF018 17,600 TDR&TXV 12.00 10.90 COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE CC5A/CD5AA018 17,200 TDR 12.5 12.5 11.6 CC5A/CD5AA024 17,500 TDR 13 13 11.85 CC5A/CD5AW024 17,500 TDR 13 13 11.85 CE3AA024 17,500 TDR 13 13 11.85 CK3BA024 17,500 TDR 13 13 12 CK5A/CK5BA018 17,200 TDR 13 13 11.75 CK5A/CK5BA024 17,500 TDR 13 13 12 CK5A/CK5BW024 17,500 TDR 13 13 12 CK5PA018 17,200 TDR&TXV 13 11.55 CK5PA024 17,500 TDR&TXV 13 11.9 CK5PW024 17,500 TDR&TXV 13 11.9 COILS + 58MVP060-14 VARIABLE SPEED FURNACE CC5A/CD5AW024 17500 TDR 13.00 13.00 11.75 CE3AA024 17500 TDR 13.00 13.00 11.80 CK5A/CK5BW024 17500 TDR 13.00 13.00 11.90 CK5A/CK5BA030* 23,200 NONE 12.00 12.00 10.30 CC5A/CD5AA024 23,000 NONE 11.70 11.70 10.15 CC5A/CD5AA030 23,200 NONE 12.00 12.00 10.20 CC5A/CD5AW024 23,000 NONE 11.70 11.70 10.15 CC5A/CD5AW030 23,200 NONE 12.00 12.00 10.20 CE3AA024 23,000 NONE 12.00 12.00 10.25 CE3AA030 23,200 NONE 12.00 12.00 10.35 CF5AA024 23,000 NONE 11.70 11.70 10.20 CK3BA024 23,000 NONE 11.70 11.70 10.30 CK3BA030 23,200 NONE 12.00 12.00 10.30 CK5A/CK5BA024 23,000 NONE 11.70 11.70 10.30 CK5A/CK5BW024 23,000 NONE 11.70 11.70 10.30 CK5A/CK5BW030 23,200 NONE 12.00 12.00 10.30 F(A,B)4(A,B)N(F,C)024 23,200 TDR 12.00 12.00 10.35 F(A,B)4(A,B)N(F,C)030 23,600 TDR 12.20 12.20 10.50 FC4(B,C)NF024** 23,200 TDR & TXV 12.00 10.30 FC4(B,C)NF030** 23,600 TDR & TXV 12.20 10.40 FF1DNA024 23,000 TDR 11.70 11.70 10.20 FF1DNA030 23,600 TDR 12.00 12.00 10.35 FG3AAA024 22,800 NONE 11.70 11.70 10.05 FK4(C,D)NF001** 23,400 TDR & TXV 13.00 11.35 40FK(A,B)/FK4(C,D)NF002** 23,600 TDR & TXV 13.50 11.45 40FK(A,B)/FK4(C,D)NF003** 23,600 TDR & TXV 13.50 11.65 FV4(A,B)NF002 23,600 TDR & TXV 13.50 13.50 11.45 FV4(A,B)NF003 23,600 TDR & TXV 13.70 13.70 11.65 FX4(A,B)NF030 23,600 TDR & TXV 12.20 12.20 10.55 COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE CC5A/CD5AA024 23,000 TDR 12.5 12.5 10.9 CC5A/CD5AA030 23,200 TDR 13 13 11.15 CC5A/CD5AW024 23,000 TDR 12.5 12.5 10.9 CC5A/CD5AW030 23,200 TDR 13 13 11.15 CE3AA024 23,000 TDR 12.5 12.5 11 CE3AA030 23,200 TDR 13 13 11.15 CK3BA024 23,000 TDR 12.5 12.5 11.1 CK3BA030 23,200 TDR 13 13 11.2 CK5A/CK5BA024 23,000 TDR 12.5 12.5 11.1 CK5A/CK5BA030 23,200 TDR 13 13 11.2 CK5A/CK5BW024 23,000 TDR 12.5 12.5 11.1 CK5A/CK5BW030 23,200 TDR 13 13 11.2 CK5PA024 23,000 TDR&TXV 12.5 11.1 CK5PA030 23,200 TDR&TXV 13 11.2 CK5PW024 23,000 TDR&TXV 12.5 11.1 CK5PW030 23,200 TDR&TXV 13 11.2 COILS + 58MVP040-14 VARIABLE SPEED FURNACE CC5A/CD5AW030 23,200 TDR 13.00 13.00 11.05 CK5A/CK5BW030 23,200 TDR 13.00 13.00 11.10 EER

Combination ratings continued SIZE-SERIES 024-32, 33 030-32, 33 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV COILS + 58MVP060-14 VARIABLE SPEED FURNACE CC5A/CD5AW024 23,000 TDR 12.50 12.50 10.85 CC5A/CD5AW030 23,200 TDR 13.00 13.00 11.00 CK3BA024 23,000 TDR 12.50 12.50 11.00 CK3BA030 23,200 TDR 13.00 13.00 11.10 CK5A/CK5BW024 23,000 TDR 12.50 12.50 11.00 CK5A/CK5BW030 23,200 TDR 13.00 13.00 11.10 COILS + 58MVP080-14 VARIABLE SPEED FURNACE CC5A/CD5AW024 23,000 TDR 12.50 12.50 11.10 CC5A/CD5AW030 23,200 TDR 13.00 13.00 11.20 CK5A/CK5BW024 23,000 TDR 12.50 12.50 11.25 CK5A/CK5BW030 23,200 TDR 13.00 13.00 11.30 CK5A/CK5BA036* 29,000 NONE 12.00 12.00 10.65 CC5A/CD5AA030 28,000 NONE 11.70 11.70 10.30 CC5A/CD5AA036 29,000 NONE 12.00 12.00 10.60 CC5A/CD5AW030 28,000 NONE 11.70 11.70 10.30 CD5AW036 29,000 NONE 12.00 12.00 10.60 CE3AA030 28,000 NONE 11.70 11.70 10.45 CE3AA036 28,200 NONE 12.00 12.00 10.50 CF5AA036 28,800 NONE 12.00 12.00 10.55 CK3BA030 28,000 NONE 11.70 11.70 10.35 CK3BA036 29,000 NONE 12.00 12.00 10.65 CK5A/CK5BA030 28,000 NONE 11.70 11.70 10.35 CK5A/CK5BN036 29,000 NONE 12.00 12.00 10.65 CK5A/CK5BT036 29,000 NONE 12.00 12.00 10.65 CK5A/CK5BW030 28,000 NONE 11.70 11.70 10.35 CK5A/CK5BW036 29,000 NONE 12.00 12.00 10.65 F(A,B)4(A,B)N(F,C)030 28,200 TDR 12.00 12.00 10.50 F(A,B)4(A,B)N(F,C)036 28,400 TDR 12.00 12.00 10.35 FC4(B,C)NF030** 27,800 TDR & TXV 11.70 10.45 FC4(B,C)NF036** 28,000 TDR & TXV 12.00 10.30 FF1DNA030 28,400 TDR 12.00 12.00 10.45 FG3AAA036 28,200 NONE 12.00 12.00 10.45 FK4(C,D)NF001** 28,000 TDR & TXV 13.00 11.40 40FK(A,B)/FK4(C,D)NF002** 28,400 TDR & TXV 13.00 11.45 40FK(A,B)/FK4(C,D)NF003** 28,400 TDR & TXV 13.50 11.80 40FK(A,B)/FK4(C,D)NF005** 29,200 TDR & TXV 14.00 12.15 FV4(A,B)NF002 28,400 TDR & TXV 13.20 13.20 11.45 FV4(A,B)NF003 28,800 TDR & TXV 13.70 13.70 11.80 FV4(A,B)NF005 29,200 TDR & TXV 14.00 14.00 12.15 FX4(A,B)NF030 27,800 TDR & TXV 12.00 12.00 10.60 FX4(A,B)NF036 28,000 TDR & TXV 12.00 12.00 10.40 COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE CC5A/CD5AA030 27,800 TDR 12.5 12.5 11.1 CC5A/CD5AA036 28,800 TDR 13 13 11.45 CC5A/CD5AW030 27,800 TDR 12.5 12.5 11.1 CE3AA030 28,200 TDR 12.5 12.5 11.2 CE3AA036 28,000 TDR 12.5 12.5 11.3 CK3BA030 27,800 TDR 12.5 12.5 11.15 CK3BA036 28,800 TDR 13 13 11.5 CK5A/CK5BA030 27,800 TDR 12.5 12.5 11.15 CK5A/CK5BA036 28,800 TDR 13 13 11.5 CK5A/CK5BT036 28,800 TDR 13 13 11.5 CK5A/CK5BW030 27,800 TDR 12.5 12.5 11.15 CK5PA030 28,000 TDR&TXV 12.5 11.1 CK5PA036 28,800 TDR&TXV 13 11.5 CK5PT036 28,800 TDR&TXV 13 11.5 CK5PW030 28,000 TDR&TXV 12.5 11.1 COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE CC5A/CD5AA036 28,800 TDR 13 13 11.6 CC5A/CD5AW030 27,800 TDR 12.5 12.5 11.25 CC5A/CD5AW036 28,800 TDR 13 13 11.6 CE3AA030 28,200 TDR 12.5 12.5 11.35 CE3AA036 28,600 TDR 13 13 11.5 CK3BA030 27,800 TDR 12.5 12.5 11.3 CK3BA036 29,000 TDR 13 13 11.65 CK5A/CK5BA030 27,800 TDR 12.5 12.5 11.3 CK5A/CK5BA036 29,000 TDR 13 13 11.65 CK5A/CK5BW030 27,800 TDR 12.5 12.5 11.3 CK5A/CK5BW036 29,000 TDR 13 13 11.65 CK5PA030 28,200 TDR&TXV 12.5 11.25 CK5PA036 29,000 TDR&TXV 13 11.65 CK5PT036 29,000 TDR&TXV 13 11.65 CK5PW030 28,200 TDR&TXV 12.5 11.25 CK5PW036 29,000 TDR&TXV 13 11.65 COILS + 58MVP040-14 VARIABLE SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 12.50 10.80 CD5AW036 29,000 TDR 13.00 13.00 11.30 CK5A/CK5BW030 28,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 13.00 11.60 EER 9

Combination ratings continued 10 SIZE-SERIES 030-32, 33 036-32, 33, 34 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV COILS + 58MVP060-14 VARIABLE SPEED FURNACE CC5A/CD5AA036 29,000 TDR 13.00 13.00 11.25 CC5A/CD5AW030 28,000 TDR 12.50 12.50 10.80 CK3BA030 28,000 TDR 12.50 12.50 10.85 CK3BA036 29,000 TDR 13.00 13.00 11.30 CK5A/CK5BA036 29,000 TDR 13.00 13.00 11.30 CK5A/CK5BW030 28,000 TDR 12.50 12.50 11.20 COILS + 58MVP080-14 VARIABLE SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 12.50 10.75 CD5AW036 29,000 TDR 13.00 13.00 11.40 CK5A/CK5BW030 28,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 13.00 11.60 COILS + 58MVP080-20 VARIABLE SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 12.50 10.75 CD5AW036 29,000 TDR 13.00 13.00 11.25 CK5A/CK5BW030 28,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 13.00 11.60 COILS + 58MVP100-20 VARIABLE SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 12.50 11.15 CD5AW036 29,000 TDR 13.50 13.50 11.60 CK5A/CK5BW030 28,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,000 TDR 13.00 13.00 11.60 COILS + 58MVP120-20 VARIABLE SPEED FURNACE CC5A/CD5AW030 28,000 TDR 12.50 12.50 11.10 CD5AW036 29,000 TDR 13.00 13.00 11.55 CK5A/CK5BW036 29,000 TDR 13.00 13.00 11.60 CK5A/CK5BW030 27,800 TDR 12.50 12.50 11.25 CK5A/CK5BW036 29,000 TDR 13.50 13.50 11.75 CK5A/CK5BA042* 35,000 NONE 12.00 12.00 10.55 CC5A/CD5AA036 35,000 NONE 12.00 12.00 10.55 CC5A/CD5AA042 35,000 NONE 12.00 12.00 10.55 CC5A/CD5AW042 34,800 NONE 12.00 12.00 10.45 CD5AW036 35,000 NONE 12.00 12.00 10.55 CE3AA036 34,600 NONE 11.70 11.70 10.45 CE3AA042 35,000 NONE 12.00 12.00 10.60 CF5AA036 34,800 NONE 12.00 12.00 10.50 CK3BA036 35,000 NONE 12.00 12.00 10.55 CK3BA042 35,000 NONE 12.00 12.00 10.55 CK5A/CK5BA036 35,000 NONE 12.00 12.00 10.55 CK5A/CK5BA042 35,000 NONE 12.00 12.00 10.55 CK5A/CK5BT036 35,000 NONE 12.00 12.00 10.55 CK5A/CK5BT042 35,000 NONE 12.00 12.00 10.55 CK5A/CK5BW036 35,000 NONE 12.00 12.00 10.55 F(A,B)4(A,B)N(F,B,C)042 35,000 TDR 12.00 12.00 10.50 F(A,B)4(A,B)N(F,C)036 34,000 TDR 11.50 11.50 10.25 FC4(B,C)N(F,B)042** 34,000 TDR & TXV 12.00 10.45 FC4(B,C)NB054** 35,000 TDR & TXV 12.50 11.10 FC4(B,C)NF036** 33,600 TDR & TXV 11.50 10.15 FG3AAA036 34,000 NONE 11.50 11.50 10.35 40FK(A,B)/FK4(C,D)NB006** 35,400 TDR & TXV 14.00 12.25 40FK(A,B)/FK4(C,D)NF002** 34,000 TDR & TXV 12.50 11.05 40FK(A,B)/FK4(C,D)NF003** 34,200 TDR & TXV 13.00 11.50 40FK(A,B)/FK4(C,D)NF005** 35,000 TDR & TXV 13.50 11.95 FK4(C,D)NF001** 33,800 TDR & TXV 12.50 10.95 FV4(A,B)NB006 35,800 TDR & TXV 14.00 14.00 12.25 FV4(A,B)NF002 34,000 TDR & TXV 12.60 12.60 11.00 FV4(A,B)NF003 34,200 TDR & TXV 13.00 13.00 11.50 FV4(A,B)NF005 35,000 TDR & TXV 13.70 13.70 11.95 FX4(A,B)NF036 34,000 TDR & TXV 11.60 11.60 10.30 FX4(A,B)NF042 34,000 TDR & TXV 12.10 12.10 10.60 COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.5 12.5 11.1 CE3AA036 34,200 TDR 12.5 12.5 11 CE3AA042 34,600 TDR 12.5 12.5 11.25 CK3BA036 34,600 TDR 12.5 12.5 11.15 CK5A/CK5BA036 34,600 TDR 12.5 12.5 11.15 CK5A/CK5BE042 34,600 TDR 12.5 12.5 11.3 CK5A/CK5BT036 34,600 TDR 12.5 12.5 11.15 CK5PA036 34,600 TDR&TXV 12.5 11.15 CK5PE042 34,600 TDR&TXV 12.5 11.25 CK5PT036 34,600 TDR&TXV 12.5 11.15 COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.5 12.5 11.3 CC5A/CD5AA042 34,600 TDR 13 13 11.4 CC5A/CD5AW036 34,600 TDR 12.5 12.5 11.3 CE3AA036 34,200 TDR 12.5 12.5 11.2 CE3AA042 34,600 TDR 13 13 11.4 CK3BA036 34,600 TDR 12.5 12.5 11.35 CK3BA042 34,600 TDR 13 13 11.4 EER

Combination ratings continued SIZE-SERIES 036-32, 33, 34 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV CK5A/CK5BA036 34,600 TDR 12.5 12.5 11.35 CK5A/CK5BA042 34,600 TDR 13 13 11.4 CK5A/CK5BE042 34,600 TDR 13 13 11.45 CK5A/CK5BT036 34,600 TDR 12.5 12.5 11.35 CK5A/CK5BT042 34,600 TDR 13 13 11.4 CK5A/CK5BW036 34,600 TDR 12.5 12.5 11.35 CK5PA036 34,600 TDR&TXV 12.5 11.3 CK5PA042 34,600 TDR&TXV 13 11.35 CK5PE042 34,600 TDR&TXV 13 11.45 CK5PT036 34,600 TDR&TXV 12.5 11.3 CK5PT042 34,600 TDR&TXV 13 11.35 CK5PW036 34,600 TDR&TXV 12.5 11.3 COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE CC5A/CD5AA036 34,600 TDR 13 13 11.35 CC5A/CD5AA042 34,600 TDR 13 13 11.5 CC5A/CD5AW036 34,600 TDR 13 13 11.35 CC5A/CD5AW042 34,400 TDR 13 13 11.45 CE3AA036 34,200 TDR 12.5 12.5 11.3 CE3AA042 34,600 TDR 13 13 11.5 CK3BA036 34,600 TDR 13 13 11.45 CK3BA042 34,600 TDR 13 13 11.5 CK5A/CK5BA036 34,600 TDR 13 13 11.45 CK5A/CK5BA042 34,600 TDR 13 13 11.5 CK5A/CK5BT036 34,600 TDR 13 13 11.45 CK5A/CK5BT042 34,600 TDR 13 13 11.5 CK5A/CK5BW036 34,600 TDR 13 13 11.45 CK5PA036 34,600 TDR&TXV 13 11.4 CK5PA042 34,600 TDR&TXV 13 11.45 CK5PT036 34,600 TDR&TXV 13 11.4 CK5PT042 34,600 TDR&TXV 13 11.45 CK5PW036 34,600 TDR&TXV 13 11.4 COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13 13 11.45 CC5A/CD5AW036 34,600 TDR 13 13 11.3 CC5A/CD5AW042 34,400 TDR 13 13 11.4 CE3AA036 34,200 TDR 12.5 12.5 11.2 CE3AA042 34,600 TDR 13 13 11.45 CK3BA042 34,600 TDR 13 13 11.45 CK5A/CK5BA042 34,600 TDR 13 13 11.45 CK5A/CK5BT042 34,600 TDR 13 13 11.45 CK5A/CK5BW036 34,600 TDR 13 13 11.35 CK5PA042 34,600 TDR&TXV 13 11.4 CK5PT042 34,600 TDR&TXV 13 11.4 CK5PW036 34,600 TDR&TXV 13 11.35 COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13 13 11.55 CC5A/CD5AW036 34,600 TDR 13 13 11.35 CC5A/CD5AW042 34,400 TDR 13 13 11.5 CE3AA036 34,200 TDR 12.5 12.5 11.25 CE3AA042 34,600 TDR 13 13 11.55 CK3BA042 34,600 TDR 13 13 11.55 CK5A/CK5BA042 34,600 TDR 13 13 11.55 CK5A/CK5BT042 34,600 TDR 13 13 11.55 CK5A/CK5BW036 34,600 TDR 13 13 11.4 CK5PA042 34,600 TDR&TXV 13 11.5 CK5PT042 34,600 TDR&TXV 13 11.5 CK5PW036 34,600 TDR&TXV 13 11.4 COILS + 58MVP040-14 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 12.50 11.20 CD5AW036 34,600 TDR 12.50 12.50 11.10 CK5A/CK5BA042 34,600 TDR 12.50 12.50 11.25 CK5A/CK5BW036 34,600 TDR 12.50 12.50 11.15 COILS + 58MVP060-14 VARIABLE SPEED FURNACE CC5A/CD5AA036 34,600 TDR 12.50 12.50 11.10 CK3BA036 34,600 TDR 12.50 12.50 11.15 CK3BA042 34,600 TDR 12.50 12.50 11.20 CK5A/CK5BA036 34,600 TDR 12.50 12.50 11.15 COILS + 58MVP080-14 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 12.50 11.25 CD5AW036 34,600 TDR 12.50 12.50 11.20 CK3BA042 34,600 TDR 12.50 12.50 11.25 CK5A/CK5BA042 34,600 TDR 12.50 12.50 11.30 CK5A/CK5BW036 34,600 TDR 12.50 12.50 11.25 COILS + 58MVP080-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 12.50 12.50 11.15 CD5AW036 34,600 TDR 12.50 12.50 11.10 CK3BA042 34,600 TDR 12.50 12.50 11.20 CK5A/CK5BA042 34,600 TDR 12.50 12.50 11.20 CK5A/CK5BW036 34,600 TDR 12.50 12.50 11.15 EER 11

Combination ratings continued SIZE-SERIES 036-32, 33, 34 042-32, 33 See notes on pg. 16. 12 INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV COILS + 58MVP100-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 13.00 11.40 CD5AW036 34,600 TDR 13.00 13.00 11.40 CK3BA042 34,600 TDR 13.00 13.00 11.40 CK5A/CK5BA042 34,600 TDR 13.00 13.00 11.45 CK5A/CK5BW036 34,600 TDR 13.00 13.00 11.40 COILS + 58MVP120-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 34,600 TDR 13.00 13.00 11.40 CD5AW036 34,600 TDR 13.00 13.00 11.35 CK5A/CK5BA042 34,600 TDR 13.00 13.00 11.45 CK5A/CK5BW036 34,600 TDR 13.00 13.00 11.35 CK5A/CK5BA048* 40,000 NONE 12.00 12.00 10.25 CC5A/CD5AC048 39,500 NONE 11.70 11.70 10.10 CC5A/CD5AW042 39,500 NONE 11.70 11.70 10.10 CC5A/CD5AW048 40,000 NONE 12.00 12.00 10.20 CD5A/CD5AA048 40,000 NONE 12.00 12.00 10.25 CE3AA042 39,500 NONE 12.00 12.00 10.25 CE3AA048 40,000 NONE 12.00 12.00 10.30 CF5AA048 39,500 NONE 12.00 12.00 10.25 CK3BA042 39,500 NONE 11.70 11.70 10.20 CK3BA048 40,000 NONE 12.00 12.00 10.25 CK5A/CK5BA042 39,500 NONE 11.70 11.70 10.20 CK5A/CK5BA048 40,000 NONE 12.00 12.00 10.25 CK5A/CK5BT042 39,500 NONE 11.70 11.70 10.20 CK5A/CK5BT048 40,000 NONE 12.00 12.00 10.25 CK5A/CK5BW048 40,000 NONE 12.00 12.00 10.25 F(A,B)4(A,B)N(F,B,C)042 39,500 TDR 11.70 11.70 10.05 F(A,B)4(A,B)N(F,B,C)048 40,000 TDR 12.00 12.00 10.25 FC4(B,C)N(F,B)042** 38,500 TDR & TXV 11.50 9.90 FC4(B,C)N(F,B)048** 39,500 TDR & TXV 11.70 10.05 FC4(B,C)NB054** 40,500 TDR & TXV 12.20 10.65 FG3AAA048 40,000 NONE 11.70 11.70 10.20 40FK(A,B)/FK4(C,D)NB006** 40,500 TDR & TXV 13.50 11.60 40FK(A,B)/FK4(C,D)NF003** 38,500 TDR & TXV 12.50 10.85 40FK(A,B)/FK4(C,D)NF005** 40,000 TDR & TXV 13.00 11.30 FV4(A,B)NB006 40,500 TDR & TXV 13.70 13.70 11.60 FV4(A,B)NF003 38,500 TDR & TXV 12.70 12.70 10.85 FV4(A,B)NF005 40,500 TDR & TXV 13.20 13.20 11.30 FX4(A,B)NF042 38,500 TDR & TXV 11.70 11.70 10.05 FX4(A,B)NF048 39,500 TDR & TXV 12.00 12.00 10.20 COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.5 12.5 10.85 CC5A/CD5AC048 39,000 TDR 12.5 12.5 10.85 CD5AA048 39,500 TDR 12.5 12.5 11 CE3AA042 39,000 TDR 12.2 12.2 10.9 CE3AA048 39,500 TDR 12.5 12.5 10.95 CK3BA042 39,000 TDR 12.5 12.5 10.85 CK3BA048 39,500 TDR 12.5 12.5 10.95 CK5A/CK5BA042 39,000 TDR 12.5 12.5 10.85 CK5A/CK5BA048 39,500 TDR 12.5 12.5 10.95 CK5A/CK5BE042 39,500 TDR 12.5 12.5 10.9 CK5A/CK5BT042 39,000 TDR 12.5 12.5 10.85 CK5A/CK5BT048 39,500 TDR 12.5 12.5 10.95 CK5PA042 39,000 TDR&TXV 12.5 10.85 CK5PA048 39,500 TDR&TXV 12.5 10.95 CK5PE042 39,500 TDR&TXV 12.5 10.9 CK5PT042 39,000 TDR&TXV 12.5 10.85 CK5PT048 39,500 TDR&TXV 12.5 10.95 COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.5 12.5 10.95 CC5A/CD5AC048 39,000 TDR 12.5 12.5 11 CC5A/CD5AW042 39,000 TDR 12.5 12.5 10.85 CC5A/CD5AW048 39,500 TDR 13 13 11.1 CD5AA048 39,500 TDR 12.5 12.5 11.1 CE3AA042 39,000 TDR 12.5 12.5 11 CE3AA048 39,500 TDR 12.5 12.5 11.05 CK3BA042 39,000 TDR 12.5 12.5 10.95 CK3BA048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BA042 39,000 TDR 12.5 12.5 10.95 CK5A/CK5BA048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BT042 39,000 TDR 12.5 12.5 10.95 CK5A/CK5BT048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BW048 39,500 TDR 13 13 11.1 CK5PA042 39,000 TDR&TXV 12.5 11 CK5PA048 39,500 TDR&TXV 12.5 11.1 CK5PT042 39,000 TDR&TXV 12.5 11 CK5PT048 39,500 TDR&TXV 12.5 11.1 CK5PW048 39,500 TDR&TXV 13 11.1 COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.5 12.5 10.95 CC5A/CD5AC048 39,000 TDR 12.5 12.5 11 EER

Combination ratings continued SIZE-SERIES 042-32, 33 048-32, 33 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV CC5A/CD5AW042 39,000 TDR 12.5 12.5 10.85 CC5A/CD5AW048 39,500 TDR 13 13 11.1 CD5AA048 39,500 TDR 12.5 12.5 11.1 CE3AA042 39,000 TDR 12.5 12.5 11 CE3AA048 39,500 TDR 12.5 12.5 11.05 CK3BA042 39,000 TDR 12.5 12.5 10.95 CK3BA048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BA042 39,000 TDR 12.5 12.5 10.95 CK5A/CK5BA048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BT042 39,000 TDR 12.5 12.5 10.95 CK5A/CK5BT048 39,500 TDR 12.5 12.5 11.1 CK5A/CK5BW048 39,500 TDR 13 13 11.1 CK5PA042 39,000 TDR&TXV 12.5 11 CK5PA048 39,500 TDR&TXV 12.5 11.1 CK5PT042 39,000 TDR&TXV 12.5 11 CK5PT048 39,500 TDR&TXV 12.5 11.1 CK5PW048 39,500 TDR&TXV 13 11.1 COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.5 12.5 11 CC5A/CD5AC048 39,000 TDR 12.5 12.5 11.05 CC5A/CD5AW042 39,000 TDR 12.5 12.5 10.9 CC5A/CD5AW048 39,500 TDR 13 13 11.15 CD5AA048 39,500 TDR 12.5 12.5 11.15 CE3AA042 39,000 TDR 12.5 12.5 11.05 CE3AA048 39,500 TDR 12.5 12.5 11.1 CK3BA042 39,000 TDR 12.5 12.5 11 CK3BA048 39,500 TDR 12.5 12.5 11.15 CK5A/CK5BA042 39,000 TDR 12.5 12.5 11 CK5A/CK5BA048 39,500 TDR 12.5 12.5 11.15 CK5A/CK5BT042 39,000 TDR 12.5 12.5 11 CK5A/CK5BT048 39,500 TDR 12.5 12.5 11.15 CK5A/CK5BW048 39,500 TDR 13 13 11.15 CK5PA042 39,000 TDR&TXV 12.5 11 CK5PA048 39,500 TDR&TXV 12.5 11.15 CK5PT042 39,000 TDR&TXV 12.5 11 CK5PT048 39,500 TDR&TXV 12.5 11.15 CK5PW048 39,500 TDR&TXV 13 11.15 COILS + 58MVP040-14 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.20 12.20 10.60 CC5A/CD5AW048 39,500 TDR 12.50 12.50 10.65 CK5A/CK5BA042 39,000 TDR 12.20 12.20 10.60 CK5A/CK5BW048 39,500 TDR 12.50 12.50 10.75 COILS + 58MVP060-14 VARIABLE SPEED FURNACE CK3BA042 39,000 TDR 12.50 12.50 10.60 CK5A/CK5BN048 39,500 TDR 12.45 12.45 10.55 COILS + 58MVP080-14 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 12.50 10.70 CC5A/CD5AC048 39,000 TDR 12.50 12.50 10.65 CD5AA048 39,500 TDR 12.50 12.50 10.80 CK3BA042 39,000 TDR 12.50 12.50 10.75 CK3BA048 39,500 TDR 12.50 12.50 10.85 CK5A/CK5BA042 39,000 TDR 12.50 12.50 10.75 CK5A/CK5BA048 39,500 TDR 12.50 12.50 10.85 COILS + 58MVP080-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.20 12.20 10.60 CC5A/CD5AC048 39,000 TDR 12.20 12.20 10.50 CD5AA048 39,500 TDR 12.50 12.50 10.65 CK3BA042 39,000 TDR 12.20 12.20 10.60 CK3BA048 39,500 TDR 12.50 12.50 10.75 CK5A/CK5BA042 39,000 TDR 12.20 12.20 10.60 CK5A/CK5BA048 39,500 TDR 12.50 12.50 10.75 COILS + 58MVP100-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 12.50 10.90 CC5A/CD5AC048 39,000 TDR 12.50 12.50 10.80 CD5AA048 39,500 TDR 12.50 12.50 10.95 CK3BA042 39,000 TDR 12.50 12.50 10.90 CK3BA048 39,500 TDR 12.50 12.50 11.05 CK5A/CK5BA042 39,000 TDR 12.50 12.50 10.90 CK5A/CK5BA048 39,500 TDR 13.00 13.00 11.05 COILS + 58MVP120-20 VARIABLE SPEED FURNACE CC5A/CD5AA042 39,000 TDR 12.50 12.50 10.90 CC5A/CK5AW048 39,500 TDR 12.50 12.50 11.00 CK5A/CK5BA042 39,000 TDR 12.50 12.50 10.90 CK5A/CK5BW048 39,500 TDR 12.50 12.50 11.00 CK5A/CK5BA060* 46,000 NONE 12.00 12.00 10.40 CC5A/CD5AA060 45,000 NONE 11.70 11.70 10.15 CC5A/CD5AC048 44,000 NONE 11.70 11.70 10.05 CC5A/CD5AW048 45,000 NONE 11.70 11.70 10.15 CC5A/CD5AW060 46,500 NONE 12.00 12.00 10.35 EER 13

Combination ratings continued 14 SIZE-SERIES 048-32, 33 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV CD5AA048 45,000 NONE 11.70 11.70 10.15 CE3AA048 45,000 NONE 11.70 11.70 10.25 CE3AA060 46,000 NONE 12.00 12.00 10.40 CF5AA048 44,000 NONE 11.70 11.70 10.20 CK3BA048 45,000 NONE 11.70 11.70 10.20 CK3BA060 46,000 NONE 12.00 12.00 10.40 CK5A/CK5BA048 45,000 NONE 11.70 11.70 10.20 CK5A/CK5BA060 46,000 NONE 12.00 12.00 10.40 CK5A/CK5BN060 46,000 NONE 12.00 12.00 10.50 CK5A/CK5BT048 45,000 NONE 11.70 11.70 10.20 CK5A/CK5BT060 46,000 NONE 12.00 12.00 10.40 CK5A/CK5BW048 45,000 NONE 11.70 11.70 10.20 CK5A/CK5BX060 46,500 NONE 12.00 12.00 10.50 F(A,B)4(A,B)N(F,B,C)048 45,000 TDR 11.70 11.70 10.10 F(A,B)4(A,B)N(F,B,C)060 46,000 TDR 11.70 11.70 10.10 FB4(A,B)NB070 46,500 TDR 12.00 12.00 10.45 FC4(B,C)N(F,B)048** 44,500 TDR & TXV 11.50 10.00 FC4(B,C)N(F,B)060** 45,000 TDR & TXV 11.50 9.95 FC4(B,C)NB054** 45,000 TDR & TXV 12.00 10.35 FC4(B,C)NB070** 46,000 TDR & TXV 12.00 10.30 FG3AAA048 44,000 NONE 11.50 11.50 10.15 FG3AAA060 45,000 NONE 11.70 11.70 10.30 40FK(A,B)/FK4(C,D)NB006** 46,000 TDR & TXV 13.00 11.35 40FK(A,B)/FK4(C,D)NF005** 45,000 TDR & TXV 12.50 11.05 FV4(A,B)NB006 46,000 TDR & TXV 13.20 13.20 11.35 FV4(A,B)NF005 45,000 TDR & TXV 12.70 12.70 11.00 FX4(A,B)NB060 45,500 TDR & TXV 12.00 12.00 10.30 FX4(A,B)NF048 45,000 TDR & TXV 11.70 11.70 10.15 COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE CC5A/CD5AC048 43,500 TDR 12 12 10.5 CD5AA048 44,500 TDR 12 12 10.6 CE3AA048 44,500 TDR 12 12 10.6 CE3AA060 45,000 TDR 12.5 12.5 10.9 CK3BA048 44,500 TDR 12 12 10.6 CK5A/CK5BA048 44,500 TDR 12 12 10.6 CK5A/CK5BT048 44,500 TDR 12 12 10.6 CK5PA048 44,500 TDR&TXV 12 10.6 CK5PT048 44,500 TDR&TXV 12 10.6 COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12.5 12.5 10.85 CC5A/CD5AC048 44,000 TDR 12 12 10.7 CC5A/CD5AW048 44,500 TDR 12.5 12.5 10.8 CD5AA048 44,500 TDR 12 12 10.8 CD5PX060 45,500 TDR&TXV 13 11.15 CE3AA048 44,500 TDR 12 12 10.8 CE3AA060 45,000 TDR 12.5 12.5 11.1 CK3BA048 44,500 TDR 12.5 12.5 10.8 CK3BA060 45,000 TDR 12.5 12.5 11.1 CK5A/CK5BA048 44,500 TDR 12.5 12.5 10.8 CK5A/CK5BA060 45,000 TDR 12.5 12.5 11.1 CK5A/CK5BT048 44,500 TDR 12.5 12.5 10.8 CK5A/CK5BT060 45,000 TDR 12.5 12.5 11.1 CK5A/CK5BW048 44,500 TDR 12.5 12.5 10.8 CK5A/CK5BX060 45,500 TDR 13 13 11.3 CK5PA048 44,500 TDR&TXV 12.5 10.85 CK5PA060 45,000 TDR&TXV 12.5 11.1 CK5PT048 44,500 TDR&TXV 12.5 10.85 CK5PT060 45,000 TDR&TXV 12.5 11.1 CK5PW048 44,500 TDR&TXV 12.5 10.85 CK5PX060 45,500 TDR&TXV 13 11.3 COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.5 12.5 10.8 CC5A/CD5AC048 44,000 TDR 12 12 10.65 CC5A/CD5AW048 44,500 TDR 12.5 12.5 10.75 CC5A/CD5AW060 45,500 TDR 12.5 12.5 11.05 CD5AA048 44,500 TDR 12 12 10.8 CE3AA048 44,500 TDR 12 12 10.75 CE3AA060 45,000 TDR 12.5 12.5 11.05 CK3BA048 44,500 TDR 12 12 10.75 CK3BA060 45,000 TDR 12.5 12.5 11.05 CK5A/CK5BA048 44,500 TDR 12 12 10.75 CK5A/CK5BA060 45,000 TDR 12.5 12.5 11.05 CK5A/CK5BT048 44,500 TDR 12 12 10.75 CK5A/CK5BT060 45,000 TDR 12.5 12.5 11.05 CK5A/CK5BW048 44,500 TDR 12 12 10.75 CK5A/CK5BX060 45,500 TDR 12.5 12.5 11.25 CK5PA048 44,500 TDR&TXV 12 10.8 CK5PA060 45,000 TDR&TXV 12.5 11.05 CK5PT048 44,500 TDR&TXV 12 10.8 CK5PT060 45,000 TDR&TXV 12.5 11.05 CK5PW048 44,500 TDR&TXV 12 10.8 CK5PX060 45,500 TDR&TXV 12.5 11.25 EER

Combination ratings continued SIZE-SERIES 048-32, 33 060-32, 33 See notes on pg. 16. INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 45,000 TDR 12.5 12.5 10.9 CC5A/CD5AC048 44,000 TDR 12.5 12.5 10.75 CC5A/CD5AW048 44,500 TDR 12.5 12.5 10.9 CC5A/CD5AW060 45,500 TDR 13 13 11.15 CD5AA048 44,500 TDR 12.5 12.5 10.9 CE3AA048 44,500 TDR 12 12 10.85 CE3AA060 45,000 TDR 12.5 12.5 11.15 CK3BA048 44,500 TDR 12 12 10.85 CK3BA060 45,000 TDR 12.5 12.5 11.15 CK5A/CK5BA048 44,500 TDR 12 12 10.85 CK5A/CK5BA060 45,000 TDR 12.5 12.5 11.15 CK5A/CK5BT048 44,500 TDR 12 12 10.85 CK5A/CK5BT060 45,000 TDR 12.5 11.15 CK5A/CK5BW048 44,500 TDR 12 12 10.85 CK5A/CK5BX060 45,500 TDR 13 13 11.3 CK5PA048 44,500 TDR&TXV 12 10.85 CK5PA060 45,000 TDR&TXV 12.5 11.15 CK5PT048 44,500 TDR&TXV 12 10.85 CK5PT060 45,000 TDR&TXV 12.5 11.15 CK5PW048 44,500 TDR&TXV 12 10.85 CK5PX060 45,500 TDR&TXV 13 11.3 COILS + 58MVP080-14 VARIABLE SPEED FURNACE CD5AA048 44,500 TDR 12.00 12.00 10.40 CK3BA048 44,500 TDR 12.00 12.00 10.40 CK5A/CK5BA048 44,500 TDR 12.00 12.00 10.40 COILS + 58MVP080-20 VARIABLE SPEED FURNACE CC5A/CD5A/CD5BW060 46,000 TDR 12.00 12.00 10.70 CC5A/CD5AW060 45,500 TDR 12.00 12.00 10.55 CK3BA048 44,500 TDR 12.00 12.00 10.30 CK3BA060 45,000 TDR 12.00 12.00 10.50 CK5A/CK5BA060 45,000 TDR 12.00 12.00 10.50 CK5A/CK5BN060 46,000 TDR 12.00 12.00 10.60 COILS + 58MVP100-20 VARIABLE SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 12.00 10.55 CC5A/CD5AC048 44,000 TDR 12.00 12.00 10.40 CC5A/CD5AW060 45,500 TDR 12.50 12.50 10.85 CD5AA048 44,500 TDR 12.00 12.00 10.55 CK3BA048 44,500 TDR 12.00 12.00 10.60 CK3BA060 45,000 TDR 12.00 12.00 10.45 CK5A/CK5BA048 44,500 TDR 12.00 12.00 10.60 CK5A/CK5BA060 45,000 TDR 12.00 12.00 10.80 CK5A/CK5BN060 46,000 TDR 12.00 12.00 10.90 CK5A/CK5BW060 46,000 TDR 12.50 12.50 11.00 COILS + 58MVP120-20 VARIABLE SPEED FURNACE CC5A/CD5AA060 44,500 TDR 12.00 12.00 10.60 CC5A/CD5AW048 45,000 TDR 12.00 12.00 10.60 CC5A/CD5AW060 45,500 TDR 12.50 12.50 10.90 CK3BA060 45,000 TDR 12.00 12.00 10.55 CK5A/CK5BA060 45,000 TDR 12.00 12.00 10.85 CK5A/CK5BW048 44,500 TDR 12.00 12.00 10.65 CK5A/CK5BW060 46,000 TDR 12.50 12.50 11.05 CK5A/CK5BA060* 57,000 NONE 12.00 12.00 10.20 CC5A/CD5AA060 55,000 NONE 11.50 11.50 9.95 CC5A/CD5AW060 58,000 NONE 11.70 11.70 10.20 CE3AA060 57,000 NONE 12.00 12.00 10.25 CK3BA060 57,000 NONE 12.00 12.00 10.20 CK5A/CK5BT060 57,000 NONE 12.00 12.00 10.20 CK5A/CK5BX060 58,000 NONE 12.00 12.00 10.35 F(A,B)4(A,B)N(F,B,C)060 57,000 TDR 11.50 11.50 9.95 FB4(A,B)NB070 58,000 TDR 12.00 12.00 10.30 FC4(B,C)N(F,B)060** 57,000 TDR & TXV 11.50 9.85 FC4(B,C)NB070** 58,000 TDR & TXV 12.00 10.15 FG3AAA060 56,000 NONE 11.50 11.50 10.10 40FK(A,B)/FK4(C,D)NB006** 58,000 TDR & TXV 12.50 10.75 FV4(A,B)NB006 58,000 TDR & TXV 12.50 12.50 10.75 FX4(A,B)NB060 56,000 TDR & TXV 12.00 12.00 10.15 COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.25 CD5PX060 58,500 TDR&TXV 12 10.55 CE3AA060 58,000 TDR 12 12 10.6 CK3BA060 58,000 TDR 12 12 10.5 CK5A/CK5BA060 58,000 TDR 12 12 10.5 CK5A/CK5BT060 58,000 TDR 12 12 10.5 CK5A/CK5BX060 58,000 TDR 12.5 12.5 10.7 EER 15

Combination ratings continued SIZE-SERIES INDOOR TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT Standard Rating SEER Carrier Gas Furnace or TDR Puron TXV CK5PA060 58,000 TDR&TXV 12 10.5 CK5PT060 58,000 TDR&TXV 12 10.5 CK5PX060 58,000 TDR&TXV 12.5 10.7 COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.2 CC5A/CD5AW060 58,000 TDR 12 12 10.5 CE3AA060 58,000 TDR 12 12 10.55 CK3BA060 58,000 TDR 12 12 10.45 CK5A/CK5BA060 58,000 TDR 12 12 10.45 CK5A/CK5BT060 58,000 TDR 12 12 10.45 CK5A/CK5BX060 58,000 TDR 12.5 12.5 10.7 CK5PA060 58,000 TDR&TXV 12 10.45 CK5PT060 58,000 TDR&TXV 12 10.45 060-32, 33 CK5PX060 58,000 TDR&TXV 12.5 10.7 COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE CC5A/CD5AA060 56,000 TDR 12 12 10.3 CC5A/CD5AW060 57,000 TDR 12 12 10.5 CD5PX060 58,500 TDR&TXV 12.5 10.65 CE3AA060 58,000 TDR 12 12 10.65 CK3BA060 58,000 TDR 12 12 10.55 CK5A/CK5BA060 58,000 TDR 12 12 10.55 CK5A/CK5BT060 58,000 TDR 12 12 10.55 CK5A/CK5BX060 58,000 TDR 12.5 12.5 10.75 CK5PA060 58,000 TDR&TXV 12 10.55 CK5PT060 58,000 TDR&TXV 12 10.55 CK5PX060 58,000 TDR&TXV 12.5 10.75 CD5PX060 58,500 PURON-TXV 12 12 10.3 * Tested combination In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR. Based on computer simulation. TXV must be Carrier specific Puron (R-410A) compatible and hard shutoff type. ** Ratings shown are with R-22 TXV replaced with Puron (R-410A) TXV. EER Energy Efficiency Ratio SEER Seasonal Energy Efficiency Ratio TDR Time-Delay Relay TXV Puron Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 16