Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Similar documents
Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

Disconnectors FA range 750VDC 250 to 2000Amp

Disconnectors FA range 1500VDC 250 to 2000Amp

DBM Range 1500VDC (13,5kA to 20kA)

Disconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)

High Power Switches. Expertly engineered for reliable performance. L High Power Switches

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

High Power Switchgear. We can create a solution that s both effective and cost-effective

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Section 2 - Substation Switchgear

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

BETA Switching Switches and Light Indicators

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

UL 508 Non-Fusible Disconnect Switches

045 : 2000 CEB STANDARD

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

PIX-H Metal-clad switchgear up to 17.5kV

Gas Insulated Switchgear

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Publication No.: PSG

UL 508 Non-Fusible Disconnect Switches

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

SWITCH FUSES 3KL71 from 32A to 800A Description

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Breakers and Switches. Switches Switch-disconnectors OT and OTM

RAPIER DSB Disconnectors

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Switch-disconnectors OT , OETL 3150

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

An innovative technology

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Disconnectors and earthing switches up to 25 kv AC

Elimsan High Voltage Disconnectors

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Protistor size 70 gr 690VAC (IEC)

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

TGK Prefabricated Substation Technical Data

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

DMX 3 -I 2500 switch disconnectors

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

NXPLUS C Single busbar. Maintenance-free for lifetime

cor Long Run Experience

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

33KV INDOOR SWITCHGEAR

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

DPX Magnetic only

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

UltraSafe US22 Modular fuse-holders

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)


Fuse switch disconnectors

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Protistor size 120 gr 750VDC (IEC)

SD Series Non-Fused Load Switches

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

DPX earth leakage DPX 3 -I earth leakage

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

ype UP T Busplugs Low Voltage Switchboard Equipment

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Scheda prodotto Relè Series B

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Control switch/load disconnect switch Series 8008

Scheda prodotto Relè Series E

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

3TM Vacuum Contactors

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

DPX 1600 Electronic release

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Euroload Changeover Switch

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Benefits, typical uses

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Transcription:

Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances and robustness for heavy duty requirements with very limited maintenance. Mersen offers one of the largest product ranges on the market and is the global leader. Mersen has a switch solution that will meet your unique needs. Our standard HUVS Change-over High Power Switches are rigorously engineered to meet your technical specifications. Operation : They can be operated manually, with a pneumatic piston or with an adapted motor (see list) up to 50.000 cycles thanks to fixed cast copper connections. Phase to Phase distance, Signaling, Terminal Box or Locking system can be studied and customized. Small making or braking capacity (on request) Maximum frequency up to 175Hz Indoor in a currentless state Ambient air should not exceed +40 C (otherwise please consult) Altitude should not exceed 1000 m Relative humidity should not exceed 95% List 2 following IEC 62271-1 Features Benefits z No Load Operation z Indoor Type - Horizontal axis mounting (Vertical under study) z Configuration with 1, 2, 3 poles (more on request) z Mechanical endurance : 25.000 less or egual than 1kAmp and 50.000 cycles above 1kAmp (1 cycle = open + close) thanks to its fixed cast copper contacts z Maximum temperature withstand at 130 C without damage to the switch z Electrical contact by contact blades with pressed-on Hard Silver Contact Rivets and silver-plated z Supporting insulators made of cast epoxy resin (fire classification according to UL94-V1) z Large isolation air and creepage path z Self-cleaning blade contacts z True opening and visible distance z Rugged anti-torsion construction z Full customisation with : z Manual, motor, pneumatic drives z Auxiliary switches, blocking magnets, locking devices z Dimensions and Fitting Applications z Power Conversion, Power Generation, Power Transport (Oil&Gaz turbine, Hydro plants, braking, night pump storage,...) Standards According to IEC 62271-102 www.ep.mersen.com 1

Technical data overview Size per Standard Speed/Characteristic Number of Poles Working Temperature HUVS 630A to 6300A (higher rating on request) Around 1 sec with pneumatic operation 3 to 4 seconds with motor operation (depend on the rating) 1, 2, 3 or more under study -20 C to +40 C Product range HUVS Range 36kV Rated current I n Rated peak current RMS 1 sec short-time withstand current Voltage drop HUVS103P630A36KV 630 A 65 ka 26 ka 30 mv 160 kg HUVS103P1000A36KV 1000 A 75 ka 30 ka 35 mv 160 kg HUVS103P1600A36KV 1600 A 91 ka 37 ka 35 mv 180 kg HUVS103P2000A36KV 2000 A 144 ka 58 ka 35 mv 190 kg HUVS103P3150A36KV 3150 A 159 ka 64 ka 35 mv 220 kg HUVS103P4000A36KV 4000 A 159 ka 64 ka 35 mv 240 kg HUVS103P6300A36KV 6300 A 193 ka 77 ka 35 mv 260 kg Technical Data Number of poles/phases 3 Degree of protection IP 0 Rated voltage AC Rated impulse withstand voltage BIL Phase to earth and between poles Rated impulse withstand voltage BIL across the insulating distance Dielectric withstand voltage 1min/50Hz Phase to earth and between poles Dielectric withstand voltage 1min/50Hz Across the isolating distance Design Temperature rise at rated current ( K) 1 HUVS Range 36kV www.ep.mersen.com 2 36000 V 170 kv 195 kv 70 kv 80 kv motorized on the right with 3 microswitches 60 K

Dimensions Rated current A B C D F G H I J K L 630 A 1080 300 40 140 59 900 383 82 610 290 300 Motors Motor types Code Motor voltage rating AC Mono AC 3 phases DC Code A 50Hz Code B 60Hz Code C 50Hz Code D 60Hz Code G 230VAC 220VAC 400VAC 400VAC 110VDC 220VDC Functions Customized signaling This range can be equipped with micro switches offering 10 Amp under 400VAC (or DC13 110VDC 0,5Amp) and 10 million cycles operation. These microswitches are used to signal the switch position and also to cut the power of the motor when it arrives at the end of its operation. The disconnectors can be equipped with 1, 2, 3 microswitches (more under study). Tropicalized version This range can be designed to be installed in salty atmospheres and in tropical geographical zones using stainless steel and a tropicalized version of motor or microswitches and special paints. www.ep.mersen.com 3

Functions Connetion plate adaptation To adapt the disconnector to the Busbar, we can adapt the orientation of the connecting plates (Vertically or Horizontally) Manual operation locking The disconnector in this range have their position secured in Open and Closed (or both) positions using various locking systems for complete security. - Padlocking (1 padlock diam 6mm) - Key locking using preferably a Ronis Lock - Blocking Magnets Blocking magnets Blocking magnets are used to guarantee electromechanically the position of the Disconnector using remote control. This operation can be done for one or both position (open and closed). Blocking magnet can be used missing Voltage or Voltage can be 24VDC, 48VDC, 110VDC, 230VDC and 230VAC (consumption GE40; TGN15; TGN17 between 20 to 45W) Connection box, Connection Terminal This Disconnector range can be equipped with a wiring connection terminal or connection box. Control box This Disconnector range can be equipped with a control box to operate the disconnector (open and close). www.ep.mersen.com 4

Functions Mechanical Operation Counter This Disconnector can be equipped with a mechanical operation counter (one complete cycle (open and close) = 1) to watch maintenance operations Accessories Indication facilities Length MECHANICAL OPERATION COUNTER W110902 63 mm 0,50 1 piece W110902 Microswitches D1027229 H820486 S/E SGN 2 CA SW11 D1030058 0,3 1 piece S/E SGN 4 CA SW11 D1027229 0,35 1 piece S/E SGN 6 CA SW11 L1027489 0,4 1 piece S/E SGN 8 CA SW11 B1028952 0,5 1 piece S/E SGN CDE DE SECOURS HAS H820486 0,3 1 piece Lubricants 1) weight in kg per piece or set including package Copper Grease L108501 1 1 piece www.ep.mersen.com 5

Accessories Removable handles for emergency manual operation R817113 Length ARB FLEX SSB-7 1043 P1013646 1.043 m 0,50 1 piece LIMITING TORQUE MAN D10 L170 Z819305 0.17 m 0,46 1 piece S/E MANIVELLE D10.2 170 R817113 0.17 m 0,27 1 piece S/E MANIVELLE D10.2 170 Tropical N827782 0.17 m 0,27 1 piece S/E MANIVELLE D10.2 300 Z817143 0.3 m 0,29 1 piece S/E MANIVELLE D10.2 480 Q822103 0.48 m 0,33 1 piece S/E MANIVELLE D10.2 600 E834168 0.6 m 0,60 1 piece S/E MANIVELLE D10.2 1000 L827688 1 m 0,60 1 piece S/E SGN CDE SECOURS FLEX 1043 W1013652 1.043 m 0,70 1 piece Manual operation handles Length S/E EYE LEVER D30/30 L450 H821728 450 mm 0,70 1 piece ISOLATING STICK L1120 20KV L820190 1120 mm 0,85 1 piece ISOLATING STICK L1520 45KV V908380 1520 mm 1,00 1 piece ISOLATING STICK L2020 60KV W908381 2020 mm 1,25 1 piece H821728 V908380 1) weight in kg per piece or set including package www.ep.mersen.com 6