FOR CLASS I VEHICULAR GATE OPERATORS

Similar documents
FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

RAMSET

RAM TABLE OF CONTENTS

RAMSET RAM

Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev

Eagle Access Control Systems, Inc. / (800) / (3)

INSTALLATION M ANUAL

RAM

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant

RAMSET.

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

Installation/Owner s Manual Model 9050

Installation/Owner s Manual Series 6500

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9150

Installation/Owner s Manual Series 6500

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

Installation/Owner s Manual Model 9100

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

Owner s Manual. Series 6300 Vehicular Swing Gate Operators

Installation/Owner s Manual

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator

115 VAC Control Boxes for

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

115 VAC Control Boxes for

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9500

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

115 VAC Control Boxes for

Installation/Owner s Manual

Installation/Owner s Manual 9245

UGP-712 Vehicular swing gate operator

PowerMaster Model SG

MODEL MSW Medium Duty Swing Gate Operator

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator

Actuator Arm and Control Box Mounting

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING H-10 GATE OPERATOR

Installation/Owner s Manual

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q-7 GATE OPERATOR

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING

Sliding Gate Opener User s Manual

gate operator class categories and examples

Installation/Owner s Manual

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO T E VIKING 10 GATE OPE ATO

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR

Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR. CLASS I Residential Vehicular Slide Gate Operator

IQ Gate Systems. IQ-500 Installation And Instruction Manual UL 325 and UL 991 Compliant.


TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9

Solar Control Box for

Solar Control Box for

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator

Actuator Arm and Control Box Mounting

APOLLO Gate Operators, Inc.

Solar Powered. Solar Powered. Installation/Owner s Manual Model Solar Powered Vehicular Slide Gate Operator

FSW 900 Swing Gate Operator

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING F-1 GATE OPERATOR

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

For Classes I, II, III, IV

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2S GATE OPERATOR. CLASS I Solar Residential Vehicular Slide Gate Operator

vehicular gate operator installation instructions and safety information revision B1 february 2007 CLASS I, CLASS II, CLASS III and CLASS IV

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING G-5 GATE OPERATOR SINGLE AND DUAL GATE SYSTEMS

Automatic Vehicular Gate Operating Systems: Guidelines for Specifiers, Designers, Dealers, Installers and End Users

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Vehicular Gate Operator Class I, Class II, Class III, and Class IV

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

SKC400U SLIDING GATE OPENER OWNER S MANUAL

MODEL D-SBG Single Arm Barrier Gate Operator

VIKING. installation instructions and safety information

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6S GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator

Installation Instructions and Safety Information Manual: Vehicular Gate Operator Class I, Class II, Class III, and Class IV

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR

Installation/Owner s Manual 1601 / 1602

APOLLO Gate Operators, Inc.

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant

Installation/Owner s Manual 1603

Installation/Owner s Manual 1601 / 1602

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING R-6 GATE OPERATOR. CLASS I Residential Vehicular Swing Gate Operator

RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

MODEL D-WBG Wishbone Arm Barrier Gate Operator

6002 swing gate actuator - installation guide

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

Auto Gate System. General Description. Features EL-888A. elock EL-888A is an electro-mechanical complete system for. EL-888A (Auto gate)

Transcription:

FOR CLASS I VEHICULAR GATE OPERATORS

www.ramsetinc.com

TABLE OF CONTENTS Important Safety Requirements & Instructions.... 1 Responsibilities of Installers and Technicians. 2 Important Safety Requirements by UL Standards.. 3 Classes of Vehicular Gate Operators/Recommended Electrical Connection.... 4 General Specifications... 5 Installation Specifications... 6 Hookup Electrical Power - Gate Travel Adjustment... 7 Standard Installation in Closed and Opened Position... 8 Compact Installation in Closed and Opened Position 9 Sensor Installation..10 Pushbutton Controls & Master/Slave Installation..11 Dip Switch Configuration.12-13 Terminal Strip Connections for Optional Accessories... 14-15 Ramset "Intelligate" Control Board.... 16 Wire Board Connections...17 Exploded View....18 Bill of Materials. 19-20 Troubleshooting Table... 21 Gate Entrance Safety Precautions. 22 Important Information for The Homeowner.... 23 Optional Ramset Accessories. 24 WARNING: Do not install this gate operator if you do not have experience or appropriate training with gate operators. IMPORTANT SAFETY REQUIREMENTS & INSTRUCTIONS WARNING To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the Vehicular Gate Operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the limit of travel, retest the Vehicular Gate Operator. Failure to adjust and retest the Vehicular Gate Operator properly can increase the risk of injury or death. 5. Use the Emergency Release only when power switch or circuit breaker has been turned off. Using the Emergency Release during a power failure can be a hazard if power is abruptly restored. 6. KEEP GATES PROPERLY MAINTAINED. Read the Owner s Manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS. 006.04.24 www.ramsetinc.com 1

INSTALLATION: RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE ATTEMPTING ANY INSTALLATION. DO NOT EXCEED THE EQUIPMENT SPECIFICATIONS. INSURE A SAFE AND PROPER INSTALLATION. INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE UL 325 SPECIFICATIONS. MAKE SURE TO ELIMINATE ANY PINCH POINTS EXISTING ON THE INSTALLATION. (ie. ROLLERS, ARMS etc.) SAFETY DEVICES: REMOVE OR PROTECT ALL PINCH POINTS FROM GATE OPERATORS ARMS. MAKE SURE EVERY INSTALLATION HAS A MINIMUM OF ONE SAFETY DEVICE (SUCH AS A PHOTOELECTRIC EYE OR LOOP DETECTOR). CHECK THE E.R.D. SENSITIVITY. MAKE SURE THAT ALL AREAS AROUND THE GATE ARE SAFE AND SECURE. (SUCH AS THE FRONT, REAR, AND TRAVEL AREA). COMMUNICATE WITH THE END-USER INSTRUCT THE END USER ON HOW TO SAFELY OPERATE ALL FUNCTIONS OF THE OPERATOR. INSTRUCT THE END-USER ON HOW TO SAFELY USE THE EMERGENCY RELEASE. CLEARLY LABEL AND IDENTIFY THE CIRCUIT BREAKER FOR THE OPERATOR. SHOW THE END-USER THE LOCATION OF THE CIRCUIT BREAKER FOR THE OPERATOR. THOROUGHLY EXPLAIN ANY AND ALL WARRANTIES ASSOCIATED WITH THE OPERATOR AND INSTALLATION. KEEP A COPY OF EACH MANUAL HANDY FOR FUTURE REFERENCES. PROVIDE THE END-USER WITH THE "HOME OWNERS MANUAL PACKET" (INCLUDED WITH EVERY OPERATOR). 2 www.ramsetinc.com

IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation of a Ramset gate operator, the following must be observed: (per UL 325.51.8.4). a) Install the vehicular gate operator only when: 1) The Vehicular Gate Operator is appropriate for the construction of the gate and the usage class of the gate. 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m.) above the ground to prevent a 2 1/4 inch (57.15 mm.) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. 3) All exposed pinch points are eliminated or guarded. 4) Guarding is supplied for exposed rollers. b) The Vehicular Gate Operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied a separate access opening. f) All warning signs and placards must be installed where visible in the area of the gate. g) For Vehicular Gate Operators utilizing a noncontact sensor in accordance with 30A.1.1 Type B1 non-contact sensor (photo electric sensor or the equivalent). 1) See instructions on the placement of noncontact sensors for each type of application. 2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and. 3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. h) For a Vehicular Gate Operator utilizing a contact sensor in accordance with 30A.1.1 1) One or more contact sensors shall be located at the leading edge, trailing edge, and postmounted both inside and outside of a vehicular horizontal slide gate. c) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. d) The gate must be properly installed and work freely in both directions prior to the installation of the Vehicular Gate Operator. Do not over-tighten the operator clutch to compensate for a damaged gate. e) Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Controls intended to be used to reset a Vehicular Gate Operator after 2 sequential activations of the entrapment protection device or devices must be located in the line-of-sight of the gate. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the vehicular gate operator is not subjected to mechanical damage. 5) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the vehicular gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. www.ramsetinc.com 3

CLASSES OF VEHICULAR GATE OPERATORS Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like. Vehicular swing-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which swings in an arc in a horizontal plane that is intended for use for vehicular entrance or exit to a drive, parking lot or the like. Residential vehicular gate operator-class I - A vehicular gate operator (or system) intended for use at a home of one-to four single family dwellings, or a garage or parking area associated there with. Commercial/general access vehicular gate operator-class II - A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail stores, or other buildings serving the general public. Industrial/limited access vehicular gate operator-class III - A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. Restricted access vehicular gate operator-class IV - A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. RECOMMENDED ELECTRICAL CONNECTION For a single operator use a 3 wire, 120 VAC or 220 VAC electrical circuit with a 15 amp independent circuit breaker. Loop wires and low voltage wires, should use separated conduit! NOTE: Always consult and follow all local building and electrical codes prior to installation! RECOMMENDED WIRE GAUGE AMPERE INPUT POWER MOTOR HP RUN START 120V Single Phase 1/2 4.7 5.0 MAXIMUM CONDUIT DISTANCE IN FEET USING COPPER WIRE BY WIRE SIZE 14ga. 12ga. 10ga. 8ga. up to 100' 100-350' 350-650' 800' 4 www.ramsetinc.com

GENERAL SPECIFICATIONS: Maximum Gate Size & Weight: 12' @ 400 lbs. Gate Traveling Speed: Approx. 90º opening in 16 sec. Cycles: 30 per hour. / Shipping: 75 lbs. Application: Residential. WARNING: Do not exceed the specifications. IMPORTANT: Always shut power Off before attempting to use the emergency release. POWER FAILURE RELEASE:. Heavy Duty Torque-limiter: Absorbs high impacts on gates to minimize damage on gear reducer. Heavy Duty Worm Gear: Lubricated by oil bath gives smooth and quiet operation. Electric Motor: 1/2 hp 120 VAC 5.2 amp 1625 rpm 50/60Hz continuous duty with high speed ball bearings and resettable overload button. Capacitor: Aerovox 65µƒ 240V 50/60Hz protected S 1000AFC. Heavy Duty Pillow Block Assembly: High speed sealed ball bearings. 1. Remove knob from top cap 2. Loose knob from clamp arm. Limit Switches: For accurate gate stop settings. Ramset "Intelligate" Control Board It is controlled by a programmable microprocessor that reds and precisely executes all functions. 3. Slightly bend the arms at the elbow and secure the gate from free-movement to relieve the pressure on the operator from the gate. 4. Carefully lift off the clamp release and arm. 5. Push gate open. 20" 13 1 /2" 13 1 /2" Chassis: 3/16" Hot rolled metal. Cold/zinc plated to inhibit corrosion. Cover: High-impact resistant charcoal grey polyethylene. www.ramsetinc.com 5

CONCRETE PAD CONSTRUCTION: Dimensions given for the pad are based on soil bearing shear of 2000 P.S.F. These figures may have to be adjusted depending on local soil conditions. INSTALLATION SPECIFICATIONS 1. Construct form for mounting pad according to dimensions shown in Figure 1 and 2. STANDARD INSTALLATION Gates from: 4' to 12' [ 23" ] COMPACT INSTALLATION Gates up to 10' [ 17" ] 2. Locate mounting pad according to dimensions given in illustration. 3. Level top edge of form. 4. Set reinforcing bars and wire mesh. 5. Allow pad to cure for 48 hours, and remove forms. 6. Note: conduits 6" above concrete pad. Figure 1 Figure 2 6 www.ramsetinc.com

Figure 3 HOOKUP ELECTRICAL POWER Outlet Leads NOTE: Hookup your electrical 15 amp wires direct to outlet. Figure 4 GATE TRAVEL ADJUSTMENT Cam Slams Limit Switches Gate travel is adjusted by loosening the limit Cams and positioning them until proper gate travel has been achieved. www.ramsetinc.com 7

STANDARD INSTALLATION FOR GATES FROM 4' TO 12' IN LENGTH Figure 5 SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION Figure 6 8 www.ramsetinc.com

COMPACT INSTALLATION FOR GATES UP TO 10' IN LENGTH Figure 7 MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION 20" minimum space required between, open gate and wall for this compact installation. Figure 8 www.ramsetinc.com 9

SENSOR INSTALLATION Ramset Gate Operators should not be installed without non-contact sensing devices such as Loop Detectors, photo electric sensors or the equivalent. WARNING: A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325. Reversing Loops on the ground floor, prevents gate from closing when vehicle is in loop area. Exit Loops on the ground floor, opens gate when vehicle crosses loop area. Photoelectric Safety Sensor (Photo Eye) prevents the gate from closing when any object interrupts the beam. Figure 9 10 www.ramsetinc.com

Opening Pressing this button will cause the gate to open. PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. L.E.D. s light up when Opening, Closing or Stopped Figure 10 Stop Pressing this button will cause the gate to stop moving. "Intelligate" Control Board Closing Pressing this button will cause the gate to close. Reset E.R.D. Board Push all three pushbuttons for approximately 5 seconds. All three L.E.D. s should blink. Figure 11 MASTER / SLAVE INSTALLATION Set Dip Switch (C8) "Slave Mode" to ON for slave operator. (RH) Right Hand operation requires Dip Switch (C7) "Left/Right" to be ON. Use jumper JP7 to JP7 Use 3-stranded, shielded wires (not supplied) from Master to Slave. Route low-voltage wires for Master/Slave in a conduit separate from power. Conduit for Power www.ramsetinc.com 11

DIP SWITCH CONFIGURATION Figure 12 Dip Switch Up for "ON" Dip Switch Down for "OFF" DIP SWITCH "A" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE 0 is OFF 1 is ON Switch 1 2 3 Gate Open Duration: 1 1 1 60 seconds 1 1 0 45 seconds 1 0 1 30 seconds 1 0 0 15 seconds 0 1 1 10 seconds 0 1 0 05 seconds 0 0 1 00 seconds 0 0 0 Disabled - command required to close Dip Switch "A" 4; 1/2 HP E.R.D. Sw. Function: OFF Most sensitive or when using 3/4 hp motor. ON Stronger (Less sensitive) E.R.D. for 1/2 hp motors. Dip Switch "B" 3; CONSTANT WARN (Constant warning when gate is in motion). Sw. Function: OFF No effect. ON Triggers the prewarn relay to maintain a closed contact while gate is in motion. Dip Switch "B" 4 & 5; ADDRESS 1 & ADDRESS 0 Up to four separate entrance addresses are available for installations with multiple entrance or exit locations. Master and slave gates that work together should be set to the same address. (Side gates use the address setup) Sw. 4 5 Function: 0 0 Default - Entrance 1 0 1 Entrance 2 1 0 Entrance 3 1 1 Entrance 4 DIP SWITCH "B" Dip Switch "B" 1; Not in use at this time. Leave in the Off position. Dip Switch "B" 2; PREWARN Sw. Pre Warning Relay: OFF Normal Operation ON Adds a 3-second delay before the gate moves in any direction. During This 3 second delay the PREWARN Relay maintains a closed contact. Dip Switch "B" 6; Not in use at this time. Leave in the Off position. Dip Switch "B" 7; Not in use at this time. Leave in the Off position. Dip Switch "B" 8; 3/4 HP E.R.D. Sw. Function: OFF Most sensitive or when using a 1/2 hp motors. ON Stronger (Less sensitive) E.R.D. for 3/4 hp motors. 12 www.ramsetinc.com

DIP SWITCH "C" Dip Switch "C" 1; SECURE CLOSE Sw. Function: Dip Switch "C" 7; LEFT / RIGHT Sw. Function: OFF Normal Operation ON When power is lost, then regained, control board checks status of the gate. If open and safety devices are cleared, gate will close automatically. OFF Left hand installations - All operators come factory set for left hand operation. ON Right hand installations - Reverses motor & limit switches without moving any wires. Dip Switch "C" 2; Not in use at this time. Leave in the Off position. WARNING: When installing or servicing an operator, make sure switch "C" 1 is Off. If switch "C" 1 is On, the gate will move when power is applied and severe injury may occur. Dip Switch "C" 8; SLAVE MODE Master/Slave configuration Sw. Function: OFF Master mode - single gate operation. All peripheral devices are to be connected to the master operator. ON Slave mode - used to synchronize operation between two gates. Commands are received from the master through a 3-wire, shielded cable. (Not provided with unit). Dip Switch "C" 3; RADIO CYCLE Sw. Function: OFF Normal Operation - gate only opens and closes on the limit switches. If the gate is in travel then it will always open. ON Cycle mode - gate opens and closes on the limit switches, but if in travel, then it will stop with a first command and reverse with a second command. Dip Switch "C" 4; ONE PASS Sw. Function: OFF Normal Operation - fully opens and closes ON One pass mode - The gate will open until the reversing loop is initially activated and then cleared, the gate will then close. If the reversing loop is then activated again, before the gate is fully closed, the gate will stop until the reversing loop is cleared, then continue to close. Dip Switch "C" 5; CLOSE DELAY One second delay on the closing of the gate. Dip Switch "C" 6; OPEN DELAY One second delay on the opening of the gate. www.ramsetinc.com 13

TERMINAL STRIP CONNECTION FOR OPTIONAL ACCESSORIES Figure 13 14 www.ramsetinc.com

TERMINAL STRIP CONNECTIONS Terminal # 1 - COMMON: Low voltage common. Terminal # 2 - REV LOOP: Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed. The function can be altered with Dip Switch "C" 4 (see Dip Switch Configuration ). Used with loop detectors, photo eyes, safety edges on front side of gate etc. Becomes active with a closed contact to common. Terminal # 3 - CLOSE: Closes the gate. Used with three button stations or pushbuttons. Becomes active with a closed contact to common. Terminal # 4 - FIREBOX: Opens the gate. Used with fire department key switches & controls. Opens with closed contact to common. Closes immediately when closed contact on common is removed. Terminal # 5 - EXIT: Opens the gate. Used with loop detectors, photo eyes, keypads, phone entry systems, three-button stations etc. Becomes active with a closed contact to common. Terminal # 6 - PHANTOM: Keeps the gate open when the open limit switch is activated. Used with loop detectors. Becomes active with a closed contact to common. Terminal # 7 - RADIO: Operation depends on dip switch "C" 3 (See Dip Switch Configuration ). Used with an RF receiver or pushbutton. Becomes active with a closed contact to common. Terminal # 8 - EDGE: When triggered the gate will stop. The gate will remain stopped until the detector is cleared. Once the detector is cleared, the operator will resume normal operation. If triggered twice before reaching a limit switch, the alarm will sound for 6 minutes and the control board will not accept any commands. After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation. Used with safety edge mounted on post or back of gate. Terminal # 9 and 10 - LIMIT 1 & LIMIT 2: Direction depends on Dip Switch "C" 7 (See Dip Switch Configuration ). Stops the motor from moving in one direction. These wires are preset in factory and should not be moved. Becomes active with a closed contact to common. Terminal # 11 and 12 - COMMON: Low voltage common. Terminal # 13 - +24 VAC: Provides 24 VAC for peripheral accessories. Terminal # 14 and 15 - MAG (-) & MAG (+): Supplies 24 VDC to a Magnetic Lock when the gate is closing or closed. If gate is opening or opened, then no power is supplied. Leave open if not used. Terminal # 16 - M BRAKE: Used ONLY on the Ram 50 Operator. If while the gate is closed someone or something tries to manually open the gate without a proper signal (keypad, exit loop, radio signal ), the motor will lock up for 6 minutes. After the 6 minutes, the operator will then secure close the gate. Terminal # 17 and 18 - MOTOR 1 & MOTOR 2: Supplies power to the motor. Direction depends on Dip Switch "C" 7 (see Dip Switch Configuration ). These wires are preset and connected in the factory and should not be moved. Terminal # 19 and 20 - AC HOT & NEUTRAL: 110 VAC or 220 VAC to power the operator. Voltage is predetermined at factory and cannot be changed by the installer or technician. www.ramsetinc.com 15

RAMSET INTELLIGATE CONTROL BOARD Introduction: sary board modifications between 110 VAC and Ramset s Intelligate Control Board works 220 VAC single-phase applications. Some of the with Sliding, Swinging and Overhead vehicular functions of the Control Board are: 0-60 seconds gate operators. It is controlled by a programmable microprocessor that reads and precisely and high setting, constant warning, prewarning, automatic close timer, self adjusting E.R.D. with low executes all functions of the Control Board. secure close, one pass, open & close delay, left/right The Control Board is powered by a separate hand operation, plug-in loop detectors and RS485 mounted 18 VAC transformer. This allows no neces- three wire master/slave connection. Figure 14 JP9 JP10 JP2 JP3 JP7 JP6 16 www.ramsetinc.com

JP9 - Input Power: 1,2) 24 VAC power. Connection from external transformer to power Control Board. JP3-3 Button: 1) Close 2) Stop 3) Open 4) Common Used with a 3-button station to open, stop, and close the gate. The open and close are normally open connections and the stop is a normally closed connection, remove jumper wire when connecting 3 button station. Common and stop are also used with a photo eye used to protect the backplane of the operators. WIRE BOARD CONNECTIONS JP2 - Relay Connections: 1) 24 VDC. 5) Relay Common 2) 24 VAC 6) Fully Closed-N.C. 3) 5 VDC 7-8) Constant/Prewarn 4) Fully Open-N.O. 9-10) E.R.D. Alarm. If E.R.D. is triggered twice before reaching a limit, 24 VDC is supplied to sound an alarm (included with operator). Fully Open N.O. (works with relay common) - Relay rated at 125 VAC, 2 amps. Normally open connection. Open contact occurs until the open limit is triggered. When the open limit is triggered, a closed contact occurs. JP7 - Master/Slave plug: 1) A 2) B 3) Common 4) 5 VDC 5) 24 VAC. Used to synchronize the operation between two gates. A three-wire, Shielded cable is needed to run from the A, B, & Common (JP7) of the master P.C.B. to the A, B, & Common (JP7) of the slave P.C.B. JP6 - Battery back-up plug: 1) A 2) B 3) Common 4) 5 VDC 5) 24 VAC. Use this plug when using optional battery back-up system, Ramset Keypad. Relay Common - Relay rated at 125 VAC, 2 amps. The common of the Fully Closed N.C. relay and the Fully Open N.O. relay. Fully Closed N.C. (works with relay common) - Relay rated at 125 VAC, 2 amps. Normally closed connection. Closed contact occurs until the closed limit is triggered. When the closed limit is triggered, an open contact occurs. JP10 - Loop Inputs: 1-2) Reverse 3-4) Exit 5-6) Phantom Use with ILD-24 Loop wires should be connected to this plug. JP4, JP5 & JP8 - Reverse, Exit & Phantom Sensor: Used with the Ramset ILD-24 plug-in loop detector. The Loop wires should be connected into the LOOP INPUTS plug. www.ramsetinc.com 17

RAMSET Figure 15 52 8 3 28 27 25 26 33 17 16 57 15 Exploded View 62 46 17 2 23 18 4 11 4 32 7 4 68 10 8 20 67 19 51 26 24 40 47 18 17 42 21 5 22 50 61 2 65 29 56 61 3 39 53 61 39 38 61 61 53 61 38 55 43 2 8 4 44 41 9 4 31 1 19 2 41 37 8 2 66 10 2 61 36 64 12 4 63 70 14 4 2 58 2 34 45 10 4 9 4 2 14 2 8 4 35 69 6 13 2 60 2 59 49 30 48 14 4 18 www.ramsetinc.com

BILL OF MATERIAL FOR: ITEM PART # PART DESCRIPTION 1 50-027 Gear Reducer Size 40 60:1 1 2 50-039 20 Pin Edge Connector 1 3 50-050 40 b 12 7/8" Sprocket 1 4 50-069 Limit Switch 00h-3 2 5 50-084 # 40 Drive Chain 1 6 50-091 # 6 x 1" Machine Screw 2 7 50-092 3/8-16 x 1 1/2" Hex Head Bolt 4 8 50-095 5/16-18 x 3/4" Hex Head Bolt 13 9 50-096 5/16" Lock Washer 8 10 50-097 5/16" Flat Washer 14 11 50-103 3/8-18 Hex Head Lock Nut 4 12 50-104 5/16" Hex Head Nut 4 13 50-105 # 6 Hex Head Nut 2 14 50-107 # 6 x 3/8" Machine Screw 8 15 50-110 1/2-14 x 2 1/2" Hex Head Bolt 3 16 50-111 1/2-14 x 3 1/2" Hex Head Bolt 1 17 50-112 1/2" Flat Washer 4 18 50-113 1/2-14 Nylon Lock Nut 5 19 50-114 1/4-20 Socket Head Screw 4 20 50-115 Polyethylene Cup Cover 1 21 50-117 1" x 2" x 32" Rectangular Metal Tube 1 22 50-118 1" x 2" x 42" Rectangular Metal Tube 1 23 50-126 Channel 1 24 50-127 2 1/2" Torque Limited Arbor 1 25 50-128 2 1/2" Torque Limited Washer 1 26 50-129 2 1/2" Torque Limited Friction Disc 2 27 50-130 2 1/2" Torque Limited Tension Washer 1 28 50-131 1-3/4" Torque Limited Nut 1 29 50-149 Access Door Lock 1 30 50-151 Warning Sign for Gate 2 31 50-168 Horn Alarm 1 32 50-172 3 1 1/2" Clamp Release 1 33 50-181 Torque Limited Bushing 1 34 50-183 Limited Switch Bracket 1 35 50-200 1/2 Hp 115 VAC Electric Motor 1 36 50-205 Capacitor 1 37 50-215 Rocker Switch 1 38 50-247 3/4" Sealed Ball Bearing 2 39 50-253 3/4" Collard Shaft 2 40 50-263 1/4" x 5" Key Way 1 41 50-265 3/16" x 3/4" Key Way 2 42 50-275 1 1/2" UHMW Spacer 1 43 50-295 #8 Self-Tap Sheet Metal Screw 2 44 50-299 Radio Receiver Terminal 1 www.ramsetinc.com 19

BILL OF MATERIAL FOR: ITEM PART # PART DESCRIPTION 45 50-304 120/240 Intelligate Transformer 1 46 50-337 1/2" x 1-1/2" Hex Head Bolt 1 47 50-339 1" x 2" Plastic Cap 2 48 50-401 10 Ga Heavy Duty Metal Chassis 1 49 50-402 Board Lexan Glass Cover 1 50 50-403 Polyethylene Cover 1 51 50-404 3/4" x 10" Limit Switch Shaft 1 52 50-405 40A27 Sprocket 1 53 50-406 3/4" Limit Switch Cam 2 54 50-407 1/2" x 1" Cast Iron Pulley 2 55 50-408 6" Aluminum Pulley 1 56 50-409 4L V Belt #250 1 57 50-419 1/4" x 1 1/2" x 10" Ext. Gate Bracket 1 58 50-529 #6 x 2" Machine Screw 2 59 50-511 120 VAC Double Outlet 1 60 50-526 #6 x 1/4" Machine Screw 2 61 50-539 5/16" Socket Head Screw 9 62 50-546 Internal Gate Bracket Swing Arm 1 63 50-559 Access Door Frame 1 64 50-560 Access Door 1 65 50-563 1 1/2" x 1 1/2" x 3/4" Sq. Pivot 1 66 50-564 1/2" x 1 1/2" Iron Pulley 1 67 50-565 5/16" x 1 1/2" Knob 1 68 50-566 5/16" x 1/2" Knob 1 69 50-569 Instruction Manual 1 70 50-777 Intelligate Control Board 1 20 www.ramsetinc.com

TROUBLESHOOTING TABLE RAMSET CONDITION NO LIGHTS ARE 'ON' POSSIBLE CAUSES 1. Circuit breaker popped. 2. 1/2 amp. fuse blown. 3. Power supply damaged on control Board. SOLUTION 1. Reset circuit breaker. 2. Replace 1/2 amp. fuse. 3. Return Control Board for repair. GATE MOVES A COUPLE OF FEET AND THEN REVERSES 1. E.R.D. too sensitive. 1. A) for 1/2 hp motors: turn dip switch "A" 4 'On'. B) for 3/4 hp motors: turn dip switch "B" 8 'On'. "EXIT" L.E.D. IS ALWAYS 'ON' 1. Faulty accessory connected to the "Exit". 1. Disconnect all accessories, including plug-ins, using the "Exit" input. If problem persist, contact Ramset. "REV LOOP" L.E.D. ALWAYS 'ON' 1. Faulty accessory connected to the "Rev Loop". 1. Disconnect all accessories, including plug-ins, using the "Rev Loop" input. If problem persist, contact Ramset. "RADIO" L.E.D. ALWAYS 'ON' 1. Stuck button on Transmitter 2. Faulty Receiver. 1. Check all transmitters. 2. Remove receiver. If problem persist, contact Ramset. GATE DOESN'T OPEN 1. Radio L.E.D. 'On'. 2. 10 amp. fuse blown. 3. Opening accessory not functioning. 1. See above symptoms/solutions. 2. Check/replace 10 amp. fuse. 3. Check/replace opening accessory. GATE DOESN'T CLOSE 1. No lights are 'On'. 2. Exit, Rev Loop, Radio L.E.D. 'On'. 3. 10 amp. fuse blown. 4. Thermal/overload button popped on motor. 1. See above symptoms/solutions. 2. See above symptoms/solutions. 3. Check/replace 10 amp. fuse. 4. Reset thermal/overload button on the back of the motor. GATE DOESN'T CLOSE AUTOMATICALLY 1. Dip switches "A" 1-3 are all 'Off'. 2. Dip switch not on all the way. 1. Set dip switches "A" 1-3 for auto close. 2. Turn off dip switches "A" 1-3, then turn the appropriate switches back 'On'. GATE AUTOMATICALLY OPENS, BUT DOESN'T AUTOMATICALLY CLOSE 1. Motor direction wrong. 1. Turn on dip switch "C" 7 (left/right). RADIO/RECEIVER HAS NO RANGE 1. Signal blocked. 2. Area not suitable for type of Receiver. 1. Make sure antenna is in proper position & not shorted to chassis. 2. May need to change to long range receiver. www.ramsetinc.com 21

GATE ENTRANCE SAFETY PRECAUTIONS WARNING: 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. 4. All opening devices, (such as a keypad, cardreader ), should not be installed close to the gate, where the gate could possibly cause injury. 5. Use warning signs attached on both sides of the gate. 22 www.ramsetinc.com

Opening the way Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs. Read your warranty certificate and fill out your warranty extension card. Return the warranty card, via certified mail, to Ramset within 90 days of purchase: Ramset Automatic Gate Services, Inc. 9116 De Garmo Ave. Sun Valley, CA. 91352 Never let children operate or play with gate controls. Keep the controls away from children. The entrance is for vehicles only. Pedestrians should use a separate entrance. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. Use the emergency release only when the gate is not moving. Make sure when using the foot release or hand crank, the circuit breaker for the operator is turned off. Have the technician give you a demonstration of how to use the emergency release. Keep gates properly maintained. Have a qualified gate technician service the gate operator and gate hardware every six months to a year. This includes checking of safety devices, E.R.D. and battery back up systems. Warning signs must be placed on every gate in a highly visible area. To reset the audible alarm on the gate operator you must turn the circuit breaker for the operator off for approximately 10 seconds, then back on. An exterior switch or button can also be installed on the operator to shut off the audible alarm. Always keep a good relationship with your technician and keep his or her number handy for future maintenance or emergencies. Ramset wishes to thank you for trusting us to meet your gate operator needs. www.ramsetinc.com 23

20-05 Ramset Mounting Post for Access Control RAMSET OPTIONAL ACCESSORIES 50-40 Ramset Remote Control Transmitter Ramset Radio Receiver Ramset Fire Box EMERGENCY ENTRY BOX Ramset Key Switch Box Ramset ILD-24 Plug-in Loop Detectors RKLE Ramset Keyless Entry System Ramset Magnetic Lock Ramset RPI Provides power for a 1/2 hp gate operator and accessories. For approx. 50 cycles. 24 www.ramsetinc.com

www.ramsetinc.com