DRX 100 B/N/H Circuit breaker (not adjustable)

Similar documents
DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable)

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Thermal magnetic and trip-free switches

DPX earth leakage DPX 3 -I earth leakage

DPX 630 Electronic release

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 1600 Electronic release

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DPX Electronic + earth leakage

cor Long Run Experience

DMX 3 -I 2500 switch disconnectors

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side

Protection components

Cat N 3. OVERALL DIMENSIONS

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

up to 63 A (1 module per pole)

Phase + Neutral, neutral on right side

(1,5 modules per pole)

Vistop TM isolating switches 63 to 160A


3 - Protection components Motor circuit-breakers

DPX moulded case circuit breakers

DX³ RCCBs - ID 4P up to 100 A

TX³ RCCBs 2P up to 100 A


RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

DX³ 4-pole RCBO 6000 A/10 ka

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

Essential equipment for all your requirements

Manual Motor Starters. Meta-MEC

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Breaking and protection devices

AF40... AF96 3-pole contactors Technical data

Moulded case circuit breakers

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DX³ RCBO 6000A Phase + Neutral, neutral on left

R.C.B.O. SP / 1 module

(p. 47) (p. 155) (p. 155)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

C60H-DC C curve. Catalogue numbers

Miniature Circuit Breaker

MS General Information Extended Product Type: MS

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Industrial contactors CTX-1

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

SWITCH FUSES 3KL71 from 32A to 800A Description

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Industrial Contactors CTX 3 3P 185A - 800A

Series KTU7 UL489 Molded Case Circuit Breakers

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Miniature Circuit Breakers

Technical data for manual motor starters Type MS325

01 Spectra Plus - Introduction

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

and other modular devices for low voltage installation

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Short-circuit current limiter S800-SCL-SR

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Product Line Overview. The Most Logically Designed Contact Assembly

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Low voltage moulded case circuit breaker EB2

SD Series Non-Fused Load Switches

The effective choice The benefits of a product with the highest quality standards

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Electronic circuit breaker EBU10-T

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Molded case circuit breakers

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

Transcription:

87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL FEATURES 3 7. NORMATIVE 4 8. ACCESSORIES 4 9. CURVES 6 1. USE DRX is the range of not adjustable breakers for all the applications of the tertiary and industrial sector including also large assortment of accessories of easy and fast assemblage. 3. DIMENSIONS Fixing on plate : 2. RANGE 1P 2P 3P 4P In \ Icu 25 35 10 20 35 10 20 35 15 270 40 270 50 270 00 270 20 270 60 270 10 270 30 270 70 20 270 41 270 51 270 01 270 21 270 61 270 11 270 31 270 71 25 270 42 270 52 270 02 270 22 270 62 270 12 270 32 270 72 30 270 43 270 53 270 03 270 23 270 63 270 13 270 33 270 73 40 270 44 270 54 270 04 270 24 270 64 270 14 270 34 270 74 50 270 45 270 55 270 05 270 25 270 65 270 15 270 35 270 75 60 270 46 270 56 270 06 270 26 270 66 270 16 270 36 270 76 75 270 47 270 57 270 07 270 27 270 67 270 17 270 37 270 77 100 270 48 270 58 270 08 270 28 270 68 270 18 270 38 270 78

3. DIMENSIONS (CONTINUATION) 4. MOUNTING 4.1 Delivery 4.2 Possible way to mount On plate : Vertical Horizontal 2/8

5. CABLING 6. ELECTRIC AND MECHANICAL FEATURES Cables : 6.1 Main pieces constituting the breaker Bars : 6.2 Breaking capacity (ka) Breaking Capacity (Icu) and Ics 1P 2P Ue / Icu H H B N H 110/130V ac 50 75 50 75 100 220/240V ac 25 60 25 40 100 277V ac 15 50 - - - 380/415V ac 10 35 10 20 35 440V ac - 30 10 15 30 460V ac - 30 10 15 30 480/500V ac - 20 7,5 10 20 550V ac - 20 7,5 10 20 600V ac - 10 5 5 10 690V ac - - - - - 125V dc 10 20* 10* 10* 20* 250V dc 5 10* 5* 5* 10* Ics 3P-4P % Icu 50 50 50 50 50 * 2 poles in series 3/8

6.3 Technical features Breaker DRX 100 (10-20- 35kA) Nominal current In (A) 15-100 Poles 1-2-3-4 Rated insulation voltage Ui (V) 690 Rated operating voltage (50/60 Hz) Ue (V) 600 Rated impulse withstand current Uimp (kv) 8 Nominal frequence (Hz) 50-60 Temperature of functioning ( C) -25 70 Endurance (cycles) mechanical 25000 electrical at In 8000 electrical at 0,5 In 10000 Utilization category A Suitable for isolation YES Type of protection magneto-thermic Magnetic adjustable no Thermic adjustable no Dimensions (wxhxd) (mm) 25(xP)x115x60 Neutral protection for 4P version (%) 100 6.5.2 Altitude Altitude Altitude (mt) 2000 3000 4000 Ue (V) 600 600 V 480 V In (A) (Ta=40 C) In 0,96 x In 0,93 x In 7. NORMATIVE IEC 60947-2 LOVAG Certification CB Scheme Certification In compliance with NEMA standards 7.1 Marking Références normatives Magnetic limit Im (A) In (A) 15 20 25 30 40 50 60 75 100 Im (xin) 27 20 16 13 10 10 10 10 10 6.4 Power dissipated by pole under In Power dissipated by pole under In In (A) 125 150 175 200 225 250 En (W) 11,7 10,1 13,8 18,0 22,8 21,9 6.5 Functioning in particular condition Identification of the breaking capacity 6.5.1 Temperature AMBIENT TEMPERATURE C -25-20 -10-5 0 In (A) 15 20 19 19 18 18 20 27 26 25 25 24 25 34 32 31 31 30 30 30 38 38 37 36 40 54 51 50 49 48 50 67 64 63 62 60 60 80 77 75 74 72 75 101 96 94 92 91 100 134 128 126 123 121 AMBIENT TEMPERATURE C 10 20 30 40 50 60 70 In (A) 15 17 17 16 15 15 14 12 20 23 22 21 20 20 18 16 25 29 28 27 25 25 23 21 30 35 34 32 30 30 28 25 40 46 45 43 40 40 37 33 50 58 56 54 50 50 46 41 60 69 67 64 60 60 55 49 75 86 84 80 75 75 69 62 100 115 112 107 100 100 92 82 "Tropicalisation" : exécution II (tous climats) selon guide UTE C63100 8. ACCESSORIES 8.1 Auxiliary and Alarm Contacts : Auxiliary Contact ref. 271 40 Alarm Contact ref. 271 41 Auxiliary + Alarm Contact ref. 271 42 4/8

8.2 Shunt Trips: 12 V = and ~ ref. 271 50 24 V = and ~ ref. 271 51 48 V = and ~ ref. 271 52 110/130 V ~ ref. 271 53 200/277 V ~ ref. 271 54 380/480 V ~ ref. 271 55 8.3 Undervoltage Releases: 12 V = and ~ ref. 271 60 24 V = and ~ ref. 271 61 48 V = and ~ ref. 271 62 110/130 V ~ ref. 271 63 200/240 V ~ ref. 271 64 277 V ~ ref. 271 67 380/415 V ~ ref. 271 65 440/480 V ~ ref. 271 66 8.5 Cage Terminals : Capacity: 50A Flexible cable from 2,5mm 2 to 16mm 2 (# 14 to # 6 AWG) Solid cable from 2,5mm 2 to 25mm 2 (# 14 to # 4 AWG) > 50A Flexible cable from 10mm 2 to 35mm 2 (# 8 to # 2 AWG) Solid cable from 10mm 2 to 50mm 2 (# 8 to # 1/0 AWG) Max Couple of Torque: 6 Nm Set : 3 Cage terminals for DRX100 3P 50A ref. 271 70 3 Cage terminals for DRX100 3P >50A ref. 271 71 4 Cage terminals for DRX100 4P 50A ref. 271 72 4 Cage terminals for DRX100 4P >50A ref. 271 73 60 Cage terminals for DRX100 50A ref. 271 92 60 Cage terminals for DRX100 >50A ref. 271 93 8.6 Montage sur rail DIN Adaptateur 1P ref. 271 89 2P ref. 271 90 3P/4P ref. 271 87 8.7 Insulating Shield Under Voltage Release circuit breaker's opening time maximum power 277-380-440-480V 8.4 Rotary handle : Shunt trip -STcircuit breaker's opening time <= 3ms maximum peak current V n=12vac 15 A maximum peak current V n =24Vac 7,5 A maximum peak current V n=48vac 5,5 A maximum peak current V n =60Vac 4,5 A maximum peak current V n =110Vac 2,5 A maximum peak current Vn=230Vac 1,5 A maximum peak current V n =415Vac 0,9 A maximum power 400VA - 400W -UVR- <= 3ms <= 4VA Set of 2 insulating shield for 2poles ref. 271 91 Set of 2 insulating shield for 3poles ref. 271 83 Set of 2 insulating shield for 4poles ref. 271 84 Direct ref. 271 76 8.8 Padlock device Plastic padlock device ref. 271 80 8.9 Insulating Shield Vary-depth ref. 271 76 Shiled for 3P ref. 271 81 Shiled for 4P ref. 271 82 5/8

9. CURVES 9.1 Characteristic Curve Rated operating voltage Ue (50/60 Hz) 600 Vac Nominal Current In 15 100 A Rated insulation voltage Ui 690 Vac Category of employment: A Rated impulse withstand current Uimp 6 kv Compliant to the norm: IEC 60947-2 6/8

9.2 Maximum peak let-through current (ka) 7/8

9.3 Let through specific energy Icc = estimated short circuit symmetrical current (RMS value) I 2 t (A 2 s) = pass-through specific energy 8/8