Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Similar documents
Operating Instructions CYR52

Operating Instructions Flexdip CYA112

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Proline Prosonic Flow 93T Portable

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Differential Pressure Transmitter

Installation manual wall-mounted distributor

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

DIAPHRAGM LIQUID PUMP NF 2.35

Installation Instructions

Assembly and Maintenance Manual Type ASNU

Installation Instructions

Pressure Transmitter

Assembly and Maintenance Manual Type RSBW

Technical Information Cleanfit Control CYC25

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

PowerAir Compressor Installation

ClassicSeries Compressor Installation

Operating Instructions Pedestrian Turnstile Type MPT 33

Installation manual portable distributors

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and Maintenance Manual Type AS

DIAPHRAGM LIQUID PUMP NF 1.30

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Operating Instructions Type MPT 53

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Baelz-electrodyn Actuator for modulating duty Motorized linear actuator baelz 373-E45

Oil-free piston compressors KK and piston vacuum pumps KV

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Swing Piston Compressors and Vacuum Pumps

Operating Instructions

WirelessAIR Advanced Integrated Remote

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Wilo-Control SC-Fire Jockey

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

HORTICULTURE EQUIPMENT & SERVICES

Motorized Stainless 2-Way Valves

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Declaration of Conformity

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Owner's/Installation Manual

Installation Instructions

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Operating Instructions Dipfit CPA111

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Instruction and Installation Guide

DIAPHRAGM LIQUID PUMP NF 1.25

PURE SINE WAVE DC TO AC POWER INVERTER

User Manual Rittal PMC UPS 6kVA

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

Pressure chlorine changeover unit C 7520

TPAK Series COOLANT PUMP

Technical Information Liquiline System CAT810

HL5-7K PLATFORM LIFT INSTRUCTIONS

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Signet Pressure Transmitter

SAVE THESE INSTRUCTIONS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Installation Instructions

HL4K PLATFORM LIFT INSTRUCTIONS

RPC-2 REVERSE PULSE DUST COLLECTOR

Galaxy VM. Battery Breaker Box Installation 09/

Installation Instructions Inspection Ports

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Florham Park, NJ USA Call (ASCO) for sales or service

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Micro Diaphragm Gas Sampling Pumps

EPS/ELA-Series User Manual EPS/ELA 250W

Instruction Manual. Q Series 2 Motor Control Modules - OEM

Proline Prosonic Flow 91W

ION JET NOZZLE NIH-55

Hydraulic Immediate Need Power Pack

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Signet Pressure Transmitter

Aurora Wind Interface Box

Florham Park, NJ USA Call (ASCO) for sales or service

ExBin-P Pressure switches 5 Pa Pa

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

InBin-P Pressure switches 5 Pa Pa

Type 6213 EV, 6281 EV

HL4K PONTOON LIFT INSTRUCTIONS

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Transcription:

Operating Instructions Compressed air cleaning unit - 115 VAC BA00498C/07/EN/01.13 71126039

Overview Fig. 1: Sensor installation - Front view 1 Fitting Bulkhead, 8 mm quick connect 2 Terminal strip 3 Sub panel 4 Heater 5 Air compressor A0018900

Fig. 2: Sensor installation - Side view 1 Heater 2 Air compressor A0019442

Fig. 3: Sensor installation - Connections 1 Solenoid valves 2 8 mm tube connection 3 8 mm to 6 mm tube connection A0019443

Table of contents 1 Safety instructions.......... 6 1.1 Designated use...................... 6 1.2 Installation, commissioning and operation. 6 1.3 Operational safety................... 6 1.4 Return............................ 6 1.5 Notes on safety icons and symbols....... 7 2 Identification.............. 8 2.1 Device designation................... 8 2.2 Scope of delivery.................... 9 3 Installation................ 9 3.1 Incoming acceptance, transport, storage... 9 3.2 Installation conditions............... 10 3.3 Installation instructions.............. 11 3.4 Post-installation check............... 12 4 Wiring.................. 12 4.1 Supply voltage..................... 12 4.2 Electrical connection to the transmitter.. 13 4.3 Post-connection check............... 13 4.4 CM44X cleaning program setup........ 14 5 Commissioning............ 19 5.1 Function check.................... 19 5.2 Switching on the unit................ 19 6 Technical data............ 20 6.1 Electrical connection................ 20 6.2 Performance characteristics........... 21 6.3 Environment...................... 21 Index................... 22 Endress+Hauser

Safety instructions 1 Safety instructions 1.1 Designated use The product is designed for the cyclic cleaning of all sensors with compressed air. The cleaning intervals are controlled by the connected transmitter. This compressor unit has a flexible heater installed for freeze protection and condensation prevention. Any other use than the one described here compromises the safety of persons and the entire measuring system and is not permitted. The manufacturer is not liable for damage caused by improper or non-designated use. 1.2 Installation, commissioning and operation Please note the following items: Installation, commissioning, operation and maintenance of the measuring system must only be carried out by trained technical personnel. Trained personnel must be authorized for the specified activities by the system operator. Electrical connection must only be carried out by a certified electrician. Technical personnel must have read and understood these Operating Instructions and must adhere to them. Before commissioning the entire measuring point, check all the connections. Ensure that electrical cables and hose connections are not damaged. Do not operate damaged products and secure them against unintentional commissioning. Mark the damaged product as being defective. Measuring point faults may only be rectified by authorized and specially trained personnel. If faults cannot be rectified, the products must be taken out of service and secured against unintentional commissioning. 1.3 Operational safety The product is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. Relevant regulations and standards have been observed. As the user, you are responsible for complying with the following safety conditions: Installation instructions Local prevailing standards and regulations. 1.4 Return Before returning, check the following: Talk to your Endress+Hauser Sales Center about the different modes of return. 6 Endress+Hauser

Safety instructions 1.5 Notes on safety icons and symbols 1.5.1 Embedded safety symbols according to ANSI The structure, signal words and safety colors of the signs comply with the specifications of ANSI Z535.6 ("Product safety information in product manuals, instructions and other collateral materials"). Safety message structure! DANGER Cause (/consequences) Consequences if safety message is not heeded Corrective action! WARNING Cause (/consequences) Consequences if safety message is not heeded Corrective action! CAUTION Cause (/consequences) Consequences if safety message is not heeded Corrective action NOTICE Cause/situation Consequences if safety message is not heeded Action/note Meaning This symbol alerts you to a dangerous situation. Failure to avoid the situation will result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid the situation can result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. This symbol alerts you to situations that can result in damage to property and equipment. Endress+Hauser 7

Identification 1.5.2 Document symbols È ä 1 This symbol stands for a cross-reference to a certain page (e.g. Page 1). È å 2 This symbol stands for a cross-reference to a certain graphic (e.g. Fig. 2). Additional information, tips Permitted or recommended Forbidden or not recommended 2 Identification 2.1 Device designation 2.1.1 Nameplate Fig. 4: Example of a nameplate A0018901 2.1.2 Material number Cleaning unit in housing Material number: 71194623 8 Endress+Hauser

Installation 2.2 Scope of delivery The scope of delivery comprises: 1 complete cleaning unit 1 set of Mounting Struts and Clamps 1 set of Operating Instructions 1 set of 8 mm to 6 mm quick disconnect adapters 1 set of 6 mm OD tubing 6" long (2) 10 meter length of 8 mm (5/16") tubing If you have any questions, please contact your supplier or your local sales center. 3 Installation 3.1 Incoming acceptance, transport, storage Make sure the packaging is undamaged! Inform the supplier about any damage to the packaging. Keep the damaged packaging until the matter has been settled. Make sure the contents are undamaged! Inform the supplier about damage to the contents. Keep the damaged products until the matter has been settled. Check that the order is complete and agrees with your shipping documents. The packaging material used to store or to transport the product must provide shock protection and humidity protection. The original packaging offers the best protection. Also, keep to the approved ambient conditions (see "Technical data"). If you have any questions, please contact your supplier or your local sales center. Endress+Hauser 9

Installation 3.2 Installation conditions Fig. 5: Enclosure Detail 1 Enclosure, NEMA4X, Polycarbonate 2 (2) 8 mm quick connect 3 Filter silencer 4 Cable glands (2) A0014976 10 Endress+Hauser

Installation 3.3 Installation instructions Preferably mount the cleaning unit close to the measuring point. Fig. 6: Compressor Field Mounting Kit A Rear view 1 Existing 1-1/2" diameter handrail A0014974 B Side view 2 Strut 3 Pipe clamp 4 Stock lock 5 Strut/clamp detail Quantity Item Description 4 3 Pipe clamp, B-line, non-metallic, 38.1 mm (1.50") pipe diameter 2 2 Strut, B-line, fiberglass, 41.40 mm x 25.4 mm (1.63" x 1.00") solid black 2 4 Stop lock, non-metallic 4 - Assembly hardware (4) nuts/bolts ss Endress+Hauser 11

Wiring You have the following installation options: 1. Secure the unit mounted on the strut frame. Material for floor mounting is not included. 2. Position the unit mounted on the frame on the railing or an upright post and secure to the railing/post with a pipe clamp. 3. Secure rails to backside of enclosure. 4. Bolt pipe clamp around handrail. 3.4 Post-installation check After mounting, check all the connections to ensure they are secure and leak-tight. Check all cables and hoses for damage. Check whether the cables are routed such that they are free from electromagnetic interference influences. 4 Wiring! WARNING Device is energized Inappropriate connection can cause serious injuries or death The electrical connection must only be carried out by a certified electrician. Technical personnel must have read and understood the instructions in this manual and must adhere to them. Ensure that there is no voltage at the power cable before beginning the connection work. 4.1 Supply voltage 115 VAC @ 60 Hz! CAUTION The device does not have a main switch The customer must provide a fused power outlet near the cleaning unit. 12 Endress+Hauser

Wiring 4.2 Electrical connection to the transmitter 1. Connect the cleaning unit to the CM44X transmitter by using wiring diagram below. Fig. 7: Compressor point to point wiring diagram A0018903 A 115 VAC Input NO = normally open GND = Ground B Relay 1 Liquiline CM44x NC = normally closed L = Line C Relay 2 COM = common N = Neutral 4.3 Post-connection check Checks Is the supply voltage correct? Notes 115 VAC Are the installed cables strain-relieved and not twisted? Are all the cable entries installed, tightened and sealed? Endress+Hauser 13

Wiring 4.4 CM44X cleaning program setup Function Display Press the menu button, go to Setup and press the navigator to enter. Toggle down to Additional functions and press enter. Toggle down to Cleaning and press enter. Choose one of the four cleaning functions available. The Cleaning 1 mode for a Dissolved Oxygen sensor will be used in this example. Press enter on Cleaning 1. Set up cleaning type as Standard clean. Set up Cleaning time to 15 s (seconds). A0019495 15 seconds is long enough for most applications. Set up Cleaning interval to every or every hour. Enter 00-01:00. Set Hold to On! 14 Endress+Hauser

Wiring Function Display Select Outputs. In this mode a relay can be programmed which can be used to start the cleaning device (e.g. a compressor). Toggle down to the relay that will be used to control the air compressor and press enter. Relay 3:1 will be used in this example. Set Function to Cleaning. Set Assignment to Cleaning 1 - Water. The setting here must match the Cleaning 1 (or the cleaning function you previously set up). Use ESC (Escape) to back out to the Cleaning 1 menu (this puts you back to the cleaning functions). A0019502 A0019503 A0019504 Endress+Hauser 15

Wiring Function Display Toggle down and select Start cycle if you want to start cleaning. It is usually done after commissioning is completed and the instrument is put into operation. You can use this part of the setup menu to force a cleaning to begin. When the Start cycling is activated, this display will show Stop and State of cleaning - Waiting or on. If you click on Stop, Start cycling and Start manual will appear. Choosing either one will start a cleaning cycle (manual will start only one cleaning cycle). Use ESC to back out of the cleaning functions - additional functions and go back to the Menu/Setup menu. A0019505 Enter Inputs. Choose the DO input that will be cleaned by the Cleaning 1 function (e.g. CH1: 1:1 Oxygen). Cleaning 1 could be used on multiple measurement channels. Toggle down to Extended setup, press enter. Then toggle down to Cleaning, press enter and set it to Cleaning 1 (or the cleaning function you previously set up). Use ESC to back out of the Setup functions and go back to the Menu/Setup menu. A0019506 A0019507 16 Endress+Hauser

Wiring Function Display Enter General settings! Toggle down to Automatic hold and press enter. Toggle down to Hold delay and press enter in the desired hold delay, e.g. 120 seconds. A0019508 Endress+Hauser 17

Wiring Function Display Go back to Setup/Additional functions and select Cleaning. Toggle down to Cleaning program assignment view and select it. Select the cleaning program you have setup and make sure all functions which need to be held are indicated under the appropriate cleaning program. A0019509 A0019510 A0019511 When selecting cleaning time and cleaning interval for (2) channels, the (2) channels must have different cleaning intervals. 18 Endress+Hauser

Commissioning 5 Commissioning 5.1 Function check! WARNING Leaks may occur if hose connections are not secure. Check that all connections are secure. Ensure that the power supply voltage corresponds to the voltage specified on the nameplate! 5.2 Switching on the unit! WARNING Risk of electric shock Before you open the housing, disconnect the device from the line voltage and secure it against being switched on unintentionally.! WARNING Danger! Hot surface! The surface of the compressor can become very hot. Wear protective gloves when touching the housing.! CAUTION Use the unit to transport air only. The cleaning unit should never be used to transport liquids or aggressive and/or toxic media. Protect the device against splash water and excessive dust. Endress+Hauser 19

Technical data 6 Technical data 6.1 Electrical connection 6.1.1 Power consumption Electrical Compressor Heater Motor voltage/frequency 115 VAC/60 Hz 115 VAC/60 Hz Motor type Permanent split Current at rated load 3.6 A 2.9 A Power at rated load 325 W 250 W 465 VA (compressor only) 820 VA (compressor with heater) Preset heater close/open settings 5 C (40 F) heat on, 10 C (50 F) heat off 20 Endress+Hauser

Technical data 6.2 Performance characteristics 6.2.1 Delivery rate PSI CFM LPM 00 1.6 45.3 10 1.48 42.8 20 1.37 40.5 30 1.29 38.4 40 1.21 36.8 50 1.13 33.5 60 1.05 27.3 70 0.98 21.1 Max. continuous pressure 100 PSI 6.2.2 Utilization interval Max. 3 minutes cleaning, break of at least six times the cleaning time 6.3 Environment 6.3.1 Ambient temperature range -10 to +55 C (+14 to +131 F) 6.3.2 Overheat control Automatic switch-off at T > 130 C (266 F) in the motor (winding sensor) Endress+Hauser 21

Index A Ambient temperature range................. 21 C Checking Function............................. 19 Installation........................... 12 Cleaning program setup................... 14 Commissioning........................ 6, 19 Connection Transmitter........................... 13 D Delivery rate............................ 21 Designated use........................... 6 E Electrical connection................... 13, 20 Environment............................ 21 I Icons.................................. 7 Incoming acceptance...................... 9 Installation......................... 6, 9 10 Check.............................. 12 Installation instructions.................... 11 N Nameplate.............................. 8 O Operation............................... 6 Operational safety......................... 6 Overheat control......................... 21 P Performance characteristics................. 21 Post-connection check.................... 13 Power consumption...................... 20 R Return................................. 6 S Safety icons.............................. 7 Scope of delivery......................... 9 Storage................................ 9 Supply voltage.......................... 12 Switching on the unit.................... 19 Symbols................................ 7 Document............................ 8 T Technical data.......................... 20 Transmitter Connection.......................... 13 Transport.............................. 9 U Use................................... 6 Utilization interval....................... 21 22

Endress+Hauser

BA00498C/07/EN/01.13 FM+SGML 9.0