OFX7 Operating Maintenance and Troubleshooting Manual L-4219

Similar documents
Operation & Service Manual

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Portable Filter Carts Models 5MF and 10MF

Operating instructions Form no safety definitions

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

WALKIE HIGH LIFT HYDRAULIC SYSTEM

Dodge Cool Lube 2 for Sleevoil Pillow Blocks Part Numbers , , ,

Air / Hydraulic Pump

Mudhen Portable Slurry System Owners Manual

8" - 12" Hydraulic Steel Squeeze Off Tool

BLACKMER BYPASS VALVES

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

FSL. High Viscosity Filtration Systems. hyprofiltration.com/fsl

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

Medium and high pressure pumps

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

Deister Machine Company, Inc. Heavy Duty System Saver Operating Instructions

Maintenance. Part A, Section 5. This section covers the following unit configurations.

M-3025CB-AV Fuel Pump

Operation & Service Manual

WARCO CHEMAG SERIES GH FILTERS

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions


QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

SERIES G3DB/AG3DB ELEVATOR

TC Series Cooling Systems

OFFLINE FILTRATION SYSTEMS

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

SUPERIOR PERFORMANCE

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

Purging Air From Divider Block Lubrication Systems

#9040 FUEL TANK SWEEPER

Warning and Safety Precautions

Installation and Operation Instruction Manual INSMAN-201. Industrial Multi Media Single Tank

CIRCLE SEAL CONTROLS

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

IBT Series Square Drive Torque Wrenches

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Portable Filter Carts 10MFP with Moduflow

HexPro Series Low Profile Wrenches

MICHIGAN FLUID POWER

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions

Hydronic Corporation

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Low Profile Wrenches Operation and Maintenance Manual

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

To ensure proper installation, digital pictures with contact information to before startup.

Owners Manual: - Pumps

Refinery Supply Company, Inc.

OPERATION AND MAINTENANCE MANUAL

A D J U S TA B L E O I L D R A I N OWNER S MANUAL

1600 PSI ELECTRIC PRESSURE WASHER

MOTORVAC TECHNOLOGIES INC. TRANSTECH-1000 Transmission Service System

Operating Instructions - Electric Pow'r-Riser Models

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

ADESCO.LLC. Mist Pump Unit (5-55 bbls/hr) Operator's Manual General Information

Electric Airless Sprayers Operating Instructions

Alpha Tech Pet, Inc. HydroMAID - "Mobile Automated Integrated Diluter" Rechargeable Battery

SHOP PRO FXP 95 TECHNICAL MANUAL

CW-2004-SME3: PARTS LIST FOR (AFTER SERIAL # ) Motor Horsepower: Pump Oil Capacity: Nozzle Size: CW-2004-SME3: 5.5

SHOP PRO FXP TECHNICAL MANUAL. FOR ADDITIONAL INFORMATION, VISIT TABLE OF CONTENTS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Fluid Coil Installation, Operation and Maintenance

PORTABLE LUBRICATION MANAGEMENT CATALOG. ForFluids.com

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

ENGINE DRIVEN 3 FULL TRASH PUMP

TS1251 PRESSURE DISPENSER USER'S MANUAL

Fuel Tank Sweeper #9049 OPERATOR S MANUAL

Installation Guide. Installing the FRK Hydraulic Compact Unit (HCU) on International School Buses TP-0913 Issued 1 Technical Bulletin

Installation & Operating Manual


Compact Cleaning System

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

Pneumatic High-Viscosity Filtration System Instruction Manual

Off-Line Filtration OFF-LINE FILTRATION

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Operating and Maintenance Manual Electric Motor Powered & Without Power 3 Diaphragm Pumps. Series

OPERATION AND PARTS MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

rev0 INSTALLATION & OPERATION MANUAL DUAL FLUID CIRCULATING HEATING SYSTEM MODEL DLV

Portable Filter Carts. Models 5MFP & 10MFP with Modufl ow and Intelli-Cart

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

GL Ludemann Y-Strainers

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Technical Information for PVX Series Pumps

QL 420 / 540 CARTRIDGE FILTER

WMTA6 LN SERIES SEAL-LESS MAG-DRIVE MULTI-STAGE TURBINE PUMPS

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

Transcription:

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

L-2999 Created 9.2012

User Manual OFX7 L-4219 - Table of Contents - Preface. 4 Customer Service. 4 Modifications to the Product 4 Warranty. 4 Introduction 5 Safety Instructions... 6 Operating Instructions.... 8 Connect/Disconnect Procedures... 8 Routine Cleaning... 8 Changing elements.. 9 Removing/Installing Elements... 9 Switching Fluids... 10 Taking Fluid Samples.. 11 Product Photo... 12 Appendices. 13 Appendix A: Electrical Schematic 14 Notes.... 16 HYDAC En TOC

L-4219 OFX7 User Manual Preface For you, as the owner of a product manufactured by us, we have produced this manual, comprising the most important instructions for its operation and maintenance. It is intended to help you become acquainted with the ins and outs of the product and use it properly. You should keep it in the vicinity of the product so it is always at your fingertips. Sometimes the information contained in the documentation cannot always keep up with changes made to the product as we attach considerable importance to keeping our products cutting-edge. Consequently, there might be deviations in technical details, illustrations and dimensions. If you discover errors while reading the documentation or have suggestions or other useful information, please don t hesitate to contact us: HYDAC 2260 City Line Road Bethlehem, PA 18017 Fax: 610.266.0100 www.hydacusa.com We look forward to receiving your input. Our motto: Putting experience into practice Customer Service If you have any questions, suggestions, or encounter any problems of a technical nature, please don t hesitate to contact us. When contacting us, please always include the model/type designation and article no. of the product: Fax: 610.266.0100 www.hydacusa.com Modifications to the Product We would like to point out that changes to the product (e.g. purchasing options, etc.) may result in the information in the operating instructions no longer being completely accurate or sufficient. When making modifications or performing repair work to components affecting the safety of the product, the product may not be put back into operation until it has been examined and released by a HYDAC representative. Please notify us immediately of any modifications made to the product whether by you or a third party. Warranty For the warranty provided by us, please refer to the General Terms of Sale and Delivery of HYDAC. They are available at: www.hydacusa.com 4 En HYDAC

User Manual OFX7 L-4219 Introduction HYDAC filtration skids are compact, self contained filtration systems equipped with high efficiency, high capacity elements capable of removing particulate contamination and/or water quickly, conveniently, and economically. Over 90% of all hydraulic failures are caused by contaminants in the fluid; proper filtration is essential in achieving long component life and efficient system operation. HYDAC s filter skids can serve as a supplement to on-line filters whenever adequate turnover cannot be achieved in the system, as well as for the pre-filter and transfer of fluids, and system flushing. Standard skids include a hydraulic pump, electric motor, and either a single or dual standard capacity or high capacity housing. Many different combinations allow the flexibility to match even the most specific system need. Multiple housing lengths give the option of adding additional dirt holding capacity. Environmentally friendly. The QF15 housing accepts HYDAC s high capacity coreless elements (model code 5.31... element series) as well as standard high capacity and high capacity elements (model code 1.14... element series) The all plastic construction of HYDAC coreless elements helps protect the environment and saves on disposal costs by reducing metallic waste. Coreless elements can be crushed, shredded or burned. Easy Servicing. As base-ported filter housings, element access for both the K9 and QF15 is through the cap. This makes for quick and easy element changeouts, with a minimal chance of oil spillage. Designed with the operator in mind, there is no wrestling with heavy, cumbersome filter bowls. HYDAC filtration skids provide many benefits to the user, including: Protects and extends the life of expensive components Minimizes downtime and maintenance costs Many component combinations allow the flexibility to match specific system needs Designed to handle high viscosity oils Availability of all plastic, environmentally friendly, coreless elements Base-ported filter housings provide quick and easy element replacement Portable via the four wheel cart option Drip pan minimizes oil spillage Market leading HYDAC Betamicron media provides for quick, efficient clean up, with maximum element life Availability of all plastic, environmentally friendly, coreless elements HYDAC En 5

L-4219 OFX7 User Manual Safety Instructions Throughout this manual, warnings are used to inform of conditions, which can, if proper steps are not taken, lead to serious fault condition, physical injury and death. The filter skid is designed and manufactured so it can be operated safely. However, the responsibility for safe operation rests with those who use or maintain this product. The following safety precautions are offered as a guide, which, if conscientiously followed, will minimize the possibility of accidents throughout the life of the filter skid. The filter skid should be operated only by those who have been trained and delegated to do so and who have read and understand these instructions. Failure to follow these instructions and safety precautions may result in accidents and injuries, and can result in premature component failure. Never start the filter skid with a known unsafe condition. Tag the filter skid and its power unit so others who may not know of the unsafe condition will not attempt to operate it. Install and use the filter skid only in full compliance with all pertinent federal, state and local codes or requirements. Do not modify this filter skid except with written company approval. Keep hands, arms and other parts of the body and also clothing away from moving parts. Make sure all hydraulic connections are made and shut off valves opened prior to operating unit. Wear appropriate protective equipment. Do not operate the filter skid with system pressure exceeding 150 psi. When disconnecting filter skid from the system, first be sure all power is off & shut off valves are closed. Power supply to the motor or the starter box (motor contactor and primary side of the transformer) is the responsibility of the end user. This power supply should be disconnected and locked out prior to opening the starter box or motor conduit box or servicing of any electrical component. Do not let unit operate without flow through the pump. Priming of the pump may be required. (Refer to Operating Instructions, page 9). Before starting the unit following a filter element change, be sure all shut-off valves are open. (Refer to the Changing Elements section on page 10). 6 En HYDAC

User Manual OFX7 L-4219 Qualified personnel must carry out all mechanical and electronic installation and maintenance work on the X Skid. Do NOT attempt to perform any maintenance and repair work on the powered X Skid. The input cable carries high voltage when power is applied, regardless of motor operation. There can be dangerous voltages from external controlled circuits when drive power is shut off. Exercise appropriate care when working on the unit. Do not tamper with existing circuitry or change the relief valve settings. Filtration performance of the X Skid is dependent on the proper use of HYDAC filter elements. Deviating from this can severely compromise the unit s performance. Contact HYDAC for recommendations on the appropriate selection of the element media. If the unit is not equipped with a starter box, the power source for the motor must be equipped with adequate motor starter controls and overload protection. Also, if the unit requires a power source for instrumentation, this power source must be supplied at the required voltage, AC or DC, ON/OFF switch and overload protection. This is a recirculating filtration system but with initial use, (a dry unit) will draw oil from the system. The system must be allowed to vent (breathe). Priming of the pump may be required (this can be accomplished by holding the suction line higher than the pump and pouring fluid into the hose). HYDAC En 7

L-4219 OFX7 User Manual Operating Instructions Connect/Disconnect Procedure 3-Phase Electrical Power Connections Ensure that the power source is turned off and locked out. Connect the 3-phase power to the motor or to the starter box, being sure to abide by all pertinent federal, state, and local codes. Ensure correct pump rotation as indication by the arrow. Turn power on at the source or engage the Start push button at the starter box. If unit is not equipped with a starter box, the power source for the motor must be equipped with adequate motor starter controls and overload protection. Also, if the unit requires a power source for instrumentation, this power source must be supplied at the required voltage, AC or DC,ON/OFF switch and overload protection. Single Phase Power Connections Ensure that the on/off switch is in OFF position. Plug the cord into a grounded outlet. The unit is now ready to be switched to the ON position. Connecting and Operating the Filter Skid Refer to product photo on page13. Be sure to lock the wheels in place if the skid is caster-mounted. Connect suction and pressure lines to the system for off-line filtration. (Note, OFX7 & OFX8 skids must have flooded suction lines, without any line restrictions). Open suction/pressure shut-off valves and close sampling and bleed/plug valves. Check for leaks. Shut unit off and tighten fittings/repairs as necessary. For heater operation, please refer to Appendix A. The filtration skid is equipped with pop-up indicator and/or differential pressure gauges and indicator lights. When the pressure approaches the bypass setting (40 or 50 psi), the indicator will be triggered and it is time to change the filter element. Refer to the section, entitled Changing Elements. Disconnecting the Filter Skid Engage the Stop at the starter box or turn the ON/OFF switch to the OFF position to cut the unit s power. Disconnect the cord from the power source. For 3-phase models, turn off power at the source and close all shut-off valves. Disconnect suction and pressure hoses. Caps and/or plugs should be used to cover, protect, and minimize leakage. Routine Cleaning The X Skid should be kept clear of excessive dirt and debris. 8 En HYDAC

User Manual OFX7 L-4219 Changing Elements If the unit equipped with the standard starter option, there are two indicator lights: MOTOR ON : indicator light will illuminate when motor/pump is running CHANGE ELEMENT : light will illuminate when the filter is in bypass, indicating it is time to change the element. Removing the filter element: Equipment required: 1 ½ box end or socket wrench, a container to hold dirty elements and fluid from the filter housing, and a small cup of grease. Step 1 Attach the provided micro bore bleeder hose to the HYDAC bleed port fitting in the filter housing cap to eliminate any trapped pressure. Step 2 Remove filter housing cap using the 1 ½ wrench and inspect the O-ring. Step 3 Remove element. Discard the elements with synthetic or cellulose media. Clean thoroughly and dry metal re-usable elements. Step 4 Drain the high capacity filter housing, using the drain plug in the base. Discard the fluid. Installing a new element: Step 1 Lubricate grommets located at each end of the replacement element(s). NOTE: DO NOT USE GREASE LUBRICANT IF FIRE RESISTANT FLUIDS ARE UTILIZED IN THE SYSTEM. Step 2 Install element into the filter housing, making sure element is positioned correctly on the bushing in the porting head. Step 3 Secure filter cap to filter housing using the 1 ½ wrench. Step 4 Bleed air during initial operation loosening the bleed plug located in the filter housing cap. Take care not to completely unscrew the bleed plug. After all air is purged and oil is observed at the bleed plug, re-tighten the plug. Performance of HYDAC Filtration Skids are based upon the use of HYDAC filter elements. The X series of filter skids is designed around the pressure drops and specifications of HYDAC Betamicron Media HYDAC En 9

L-4219 OFX7 User Manual Switching Fluids Cross contamination flushing: Step 1 Remove and discard elements. Step 2 Remove fluid from housings, fluid lines, and drainage tray. Step 3 Close cleanup filters and plugs. Step 4 Purge system and filter(s) with 5 gallons of new kerosene. Step 5 Bleed filter(s). Be careful not to run dry to avoid the possibility of cavitating the pump. Run for several minutes. Step 6 Remove kerosene. Step 7 Repeat steps 3 through 6 as required. Step 8 Drain the system of kerosene opening all drain ports and filter caps. Step 9 Install elements as desired for the next application. Step 10 Purge system with the new fluid; allow 2 to 3 gallons to discharge into a waste container if practical. Step 11 Circulate the fluid in the system. Step 12 Bleed the filters. 10 En HYDAC

User Manual OFX7 L-4219 Taking Fluid Samples Step 1 To initiate the sampling process, locate the sampling valve(s) at the base of the filter(s). Step 2 Pass a minimum of 200 ml of fluid through the desired sampling valve into a waste container before collecting the fluid. Step 3 Place the sampling bottle in position to collect the fluid. Use a sampling bottle having a contaminant level of at least 2 decades lower than the expected sample as qualified per the American National Standard Procedure for Qualifying and Controlling Cleaning Methods for Hydraulic Fluid Power Sample Containers, ANSI/B93.20-1972, ISO 3722-1976). Step 4 After removing the cap and plastic film from sample bottle, place the bottle under the stream of fluid. Step 5 Take a sample of not more than 90% nor less than 50% of the sampling bottle volume. Step 6 To terminate the sampling process, remove the bottle from the fluid stream and close the sample valve after removing the sample bottle from the fluid stream. Step 7 Recap the sample bottle immediately after withdrawing the hose. HYDAC En 11

L-4219 OFX7 User Manual Product Photo Relief Valve Heater (optional) Outlet Inlet 12 En HYDAC

User Manual OFX7 L-4219 Appedix A: Electrical Schematic HYDAC En 13

L-4219 OFX7 User Manual 14 En HYDAC

Notes:

Internet: www.hydacusa.com