Epoxy Technology Embedded Poles

Similar documents
ABB AG - EPDS. Vacuum interrupters

Metal Clad Air Insulated Switchgear

3AH37 and 3AH38 vacuum generator circuit-breakers for power stations and industry

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Gas Insulated Switchgear

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Air-insulated switchgear UniGear type ZS1

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

Product Group Brochure. PS Range Capacitor Vacuum Switches

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Gas Insulated Metal-clad Switchgear, HMGS!

Energy Division. PCA Single Column Polymeric Surge Arrester

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Medium Voltage Products Table Of Contents

OHB Outdoor sulphur Hexafluoride circuit-breaker

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

NXPLUS C Single busbar. Maintenance-free for lifetime

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Report No.: MS/E Copy No.: 0 Contents: 140 sheets

Innovac SVS/08 - SVS/ kv modular switchgear

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

MEDIUM VOLTAGE SWITCHGEAR

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

Outdoor vacuum breaker for railway applications - FSK II

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

34-SDMS-01 SPECIFICATIONS FOR

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Medium Voltage Products Table Of Contents

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

GROUP D. Switch & Protective device.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

TECHNICAL SPECIFICATIONS

Distribution transformers Efficiency over life-cycle

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Q pole Pole Mounted Capacitor System

Documents and Addresses

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

Prüffeld der Schaltwerke

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Vacuum Circuit Breaker

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

VD4 Installation and service instructions kv A ka

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

Solid Dielectric, Three Phase Reclosers CATALOG VS11

User manual W-VACi. W-VACi 12 / 17.5 / 24 kv IEC Vacuum Circuit Breakers

1. Safety practices General Introduction Standards...3

I-1 DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE. Overview

Benefits, typical uses

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

with Vacuum Circuit Breaker HAF

3TM Vacuum Contactors

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

ZX2 Gas-insulated medium voltage switchgear

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Transcription:

Embedded Poles ABB Power Technologies / 1-6994 E 14-03-03 -

Epoxy processing Experience in manufacturing of epoxy resin for indoor and outdoor applications Processing of more than 1,000 tons epoxy resin per year Manufacturing of components for different voltage levels Processing of insulating and conductive silicone Industrial IT based process management to ensure maximum production quality Cooperation with well-known chemical industry companies Supplier for different industries (e.g. cable, electronic device) ABB Power Technologies / 2-6995 E 14-03-03 -

ABB Power Technologies / 3-6996 E 14-03-03 -

Manufacturing of embedded poles ABB Power Technologies / 4-6997 E 14-03-03 - Components filler, resin and hardener Process sequence for direct casting of vacuum interrupters

Manufacturing of embedded poles ABB Power Technologies / 5-6998 E 14-03-03 - Mould with pre-assembled groups of vacuum interrupters Removal of finished embedded poles from the mould

Quality control Embedded poles Verification of dimensional conformity Measurement of voltage drop across the pole Mechanical functional test Inspection of contact force correctness Examination by visual assessment ABB Power Technologies / 6-6999 E 14-03-03 -

The embedded Pol 1 2 Principle structure 3 4 ABB Power Technologies / 7-7000 E 14-03-03-5 6 7 8 9 10 1 Terminal 2 Vacuum interrupter 3 Epoxy resin 4 Stem 5 Terminal 6 Flexible connection 7 Contact force spring 8 Push rod 9 Fixing point 10 Connection to drive

Embedded poles Indoor Outdoor P1 12/17.5 kv 1250 A 31.5/ 31.5 ka P4 24 kv 1250 A 25 ka P4-S 24 kv 1250 A 25 ka P3 12/17.5 kv 1600/1250 A 40/ 31.5 ka P2 12/17.5 kv 2500 A 1) 40/ 31.5 ka P5 24 kv 2500 A 1) 25 ka OP1 27 kv 800 A 16 ka OP2 38 kv 1000 A 16 ka H = 205/140 mm H = 310/205 mm H = -/205 mm H = 310/160 mm H = 310/160 mm H = 310/205 mm H = 346/247 mm H = 383/367 mm VG5 VG4 VG4-S VG5 VG4 VG4-S VG5 VG4 VG4-S VG4 VG4-S VG6 VG4-S VG6 VG4-S VS4 VG5 VG6 ABB Power Technologies / 8-7232 E 27-08-03-1) 2500 A with heat sink

Indoor poles ABB Power Technologies / 9-7004 E 14-03-03 -

Indoor pole P1 Rated Rated Rated shortvoltage current circuit breaking current 12/17.5 kv 1250 A 31.5 ka ABB Power Technologies / 10-7005 E 14-03-03 -

Indoor pole P2 Rated Rated Rated shortvoltage current circuit breaking current 12 kv 2500 A 1) 40 ka 17.5 kv 2500 A 1) 31.5 ka 1) 2500 A with heat-sink ABB Power Technologies / 11-7006 E 14-03-03 -

Indoor pole P3 Rated Rated Rated shortvoltage current circuit breaking current 12 kv 1600 A 40 ka 17.5 kv 1250 A 31.5 ka ABB Power Technologies / 12-7007 E 14-03-03 -

Indoor pole P4 Rated Rated Rated shortvoltage current circuit breaking current 24 kv 1250 A 25 ka ABB Power Technologies / 13-7008 E 14-03-03 -

Indoor pole P4-S Rated Rated Rated shortvoltage current circuit breaking current 24 kv 1250 A 25 ka ABB Power Technologies / 14-7009 E 14-03-03 -

Indoor pole P5 Rated Rated Rated shortvoltage current circuit breaking current 24 kv 2500 A 1)...25 ka 1) 2500 A with heat-sink ABB Power Technologies / 15-7010 E 14-03-03 -

Outdoor poles ABB Power Technologies / 16-7007 E 14-03-03 -

Outdoor pole OP1 Rated Rated Rated shortvoltage current circuit breaking current 27 kv 800 A 16 ka ABB Power Technologies / 17-7235 E 08-12-03 -

Outdoor pole OP2 Rated Rated Rated shortvoltage current circuit breaking current 38 kv 1000 A 16 ka ABB Power Technologies / 18-7236 E 08-12-03 -

Embedded poles Embedded poles type Rated voltage kv Rated Pow er frequency withstand voltage kv Rated lightning impulse withstand voltage kv Rated current A Short-circuit breaking current ka Mechanical operating cycles Vertical distance mm P1 12 17.5...42 75 95...1250...31.5...30,000 205 P2 12 17.5...42 75 95...2500 1)...40...31.5...30,000 310 P3 12 17.5...42 75 95...1600...1250...40...31.5...30,000 310 P4 24 50 125...1250...25...30,000 310 P4-S 24 50 125...1250...25...30,000 - P5 24 50 125...2500 1)...25...30,000 310 OP1...27...60...125...800...16...15,000 - ABB Power Technologies / 19 OP2...38...70...170...1000...16...15,000-1) 2500 A with heat sink

Vacuum interrupter in silicone embedding technique VG5 Silicone 24 kv 1250 A...16 ka 30,000 CO Silicone diameter : 75 mm VG4 Silicone 24 kv 2500 A...20 ka 30,000 CO Silicone diameter : 100 mm VG4-S Silicone 24 kv 2500 A...25 ka 30,000 CO Silicone diameter : 100 mm ABB Power Technologies / 20-7011 E 14-03-03 - VG6 Silicone 36 kv 3150 A...25 ka 30,000 CO Silicone diameter : 119 mm

Vacuum interrupters in silicone embedding technique By embedding in silicone, VIs are suitable for the application in air with higher rated voltage levels Example (in air): VG4 12 kv 2500 A 25 ka 30,000 CO Ceramic diameter : 90 mm ABB Power Technologies / 21-7019 E 14-03-03 - VG4 Silicone 24 kv 2500 A...20 ka 30,000 CO Silicone diameter : 100 mm

Embedded poles ABB Power Technologies / 22-7013 E 14-03-03 - High dielectric strength without any further external precausions Optimum protection of the vacuum interrupter from moisture, dust and external damage Suitability for different climatic conditions High reliability and long life due to modular structure Compact and robust design Easy adaption on the circuit-breaker Maintenance-free High quality standard Industrial IT enabled

ABB Power Technologies / 23