3VU13, 3VU16 Circuit-Breakers

Similar documents
Motor Protection Circuit Breakers 3VU13 and 3VU16

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Motor Circuit Breakers C3

Protection Equipment

3VT Kompaktleistungsschalter bis 630A

Motor Circuit Breakers C4

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Protection Equipment. 5/2 Introduction

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Manual Motor Starters. Meta-MEC

BETA Switching Switches and Light Indicators

Protective Devices: Circuit-Breakers 1 )

SENTRON Switching and Protection Devices Switch Disconnectors

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Motor protective circuit breakers

FMotor Circuit Controllers

Protection components

3VF3 to 3VF8 Circuit-Breakers

D509E. Manual Motor - Starters

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3 - Protection components Motor circuit-breakers

MS General Information Extended Product Type: MS

cor Long Run Experience

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Miniature Circuit-Breakers (MCBs)

Industry Automation Control Components

Low voltage switch gear

SIRIUS 3RU2 Thermal Overload Relays

Control Circuit Protection

Motor Protection Circuit Breakers

MOULDED CASE CIRCUIT BREAKERS BC160N

Bulletin 193-T1 Bimetallic Overload Relays

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

and other modular devices for low voltage installation

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

3VT1 Molded Case Circuit Breakers up to 160 A

3NP1 Fuse Switch Disconnectors up to 630 A

Miniature Circuit-Breakers (MCBs)

Manual Motor Starter MS 116. Technical Catalogue

3RT14 Contactors with 3 Main Contacts

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SENTRON VL Series Product Specifications

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Thermal Overload Relays - WEG RW Series, 2 Pole

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Motor Starter Protectors

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Electronic circuit breaker EBU10-T

DPX moulded case circuit breakers

Short form catalogue Motor protection and control Manual motor starters

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

4 - Miniature controls

BETA Switching Switching Devices

Technical Information

System Manual 02/2008

Motor Starter Protectors

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

3VT2 Molded Case Circuit Breakers up to 250 A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Technical Information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

ACS motor protection circuit breakers KT 7 Introduction

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Moulded case circuit breakers

Thermal-magnetic Miniature Circuit Breaker 4230-T...

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Technical data for manual motor starters Type MS325

MS25, MST25, MS20, MST20

Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

The effective choice The benefits of a product with the highest quality standards

Meta Solution. Contactors and Overload relays

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

3SE3 1 SIGUARD Position Switches

Selective main circuit breakers S 750 series Technical Data

SENTRON 3VT Molded Case Circuit Breakers up to 1600 A

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

DMX 3 -I 2500 switch disconnectors

Micro Contactor MA Series

Air Circuit Breakers

DPX earth leakage DPX 3 -I earth leakage

Transcription:

3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used for switching and protecting motors or other loads. They are fitted with instantaneous overcurrent releases and inverse-time delayed overload relay, 3VU6 can also be supplied with instantaneous overcurrent releases only. Circuit-breakers and contactors can be combined to form fuseless starter combinations. The 3VU3, 3VU6 circuit-breakers are suitable for use in any climate. They are designed for operation in enclosed rooms, under good operating conditions (e.g. no dust, corrosive steam or damaging gases). They must be suitably encapsulated before being installed in dusty and humid rooms. The standards to which the breakers have been constructed, permissible ambient temperatures, maximum making and breaking capacity, tripping currents and other limiting operational conditions, are given in the technical data and tripping characteristics. 3VU3 3VU6 Circuit-breakers for motor protection 3VU3 0.~25A 3VU6 ~52A The characteristic curves of these circuit-breakers are specially laid-out for the overload and short-circuit protection of motors. The inverse-time delayed releases ( a releases ) are adjustable for setting the rated current of the motors to be protected. The instantaneous short-circuit releases ( n releases ) are fixedset to 2 times the value so as to assure faultless starting of the motors. Circuit-breakers for transformer protection 3VU3 40-T.00 0.~20A The circuit-breakers for line-side protection of control transformers with a high inrush current have an adjustable delayed overload release and a fixed-set instantaneous short-circuit release that only releases instantaneously at 9 times the current. This enables transformers to be protected that have inrush peak values up to 30 times the rated current. For transformers with low inrush current, e.g. Siemens transformers, this version is not necessary. 3VU3 3VU6 Circuit breakers for plant protection 3VU3 0.~25A 3VU6 ~63A The circuit-breakers are used for the protection of cables, conductors and plant equipment against thermal overload and short-circuit. Depending on the version, there are fixed-setting or adjustable overload and short-circuit releases for optimized adaptation to the distribution system. Circuit-breakers for starter combinations 3VU6.6~52A In starter combinations consisting of a contactor and overload relay, these circuit-breakers are used for short-circuit protection of these combinations. They have fixed-setting short-circuit releases, but no overload releases. 3VU6 /

3VU3 Circuit-Breakers, up to 25A Selection and ordering data Rated current Motor Setting Range Order No. Weight n output approx. Thermal Instantaneous overload overcurrent releases releases I >> 3VU3 A kw A A kg Circuit-breakers for motor and plant protection 0.6 0.-0.6.9 3VU340 -. MB00 0.29 0.24 0.06 0.6-0.24 2.9 -. MC00 0.4 0.09/0.2 0.24-0.4 4.8 -. MD00 0.6 0.2/0.8 0.4-0.6 7.2 -. ME00 0.25 0.6-2 3VU340 -. MF00.6 0.37/0.55 -.6 9 -. MG00 2.4 0.75.6-2.4 29 -. MH00 3.2. 2-3.2 38 -. NH00 4./.5 2.4-4 48 3VU340 -. MJ00 5.5/2.2 3.2-5 60 -. NJ00 6 2.2 4-6 72 -. MK00 8 3 5-8 96 -. NK00 0 3/4 6-0 20 3VU340 -. ML00 3 4/5.5 8-3 56 -. NL00 6 7.5 0-6 90 -. MM00 20 7.5 4-20 240 -. MN00 25 8-25 300 -. MP00 Circuit-breakers for fuse monitoring No auxiliary contacts 0 with auxiliary contacts NO+NC... integrated in the circuit-breaker 2NO... 2 2NC... 3 0.2-0.2.2 3VU340 -. MS00 Circuit-breakers for line-side protection of transformers with high inrush current No auxiliary contacts 0 with auxiliary contacts NO+NC... integrated in the circuit-breaker 2NO... 2 2NC... 3 0.6-0. - 0.6 2.9 3VU340 -. TB00 0.29 0.24 0.6-0.24 4.8 -. TC00 0.4 0.24-0.4 7.2 -. TD00 0.6-0.4-0.6 2 3VU340 -. TE00 0.6-5 -. TF00.6 -.6 29 -. TG00 2.4 -.6-2.4 48 3VU340 -. TH00 4 2.4-4 72 -. TJ00 6 4-6 20 -. TK00 0-6 - 0 90 3VU340 -. TL00 6 0-6 300 -. TM00 20 4-20 300 -. TN00 with auxiliary contacts NO+NC... integrated in the circuit-breaker Note: Recommended value for standard 4-pole motors at AC50Hz 400V. The start-up data and ratings for the motor to be protected are relevant /2

Selection and ordering data 3VU6 Circuit-Breakers, up to 63A Rated current Motor Setting Range Order No. Weight n output approx. Thermal Instantaneous overload overcurrent releases releases I >> 3VU6 A kw A A kg Circuit-breakers for motor and plant protection Circuit-breakers for plant protection.6 0.37/0.55 -.6 9 3VU640 -. MG00 0.76 2.4 0.75.6-2.4 29 -. MH00 4./.5 2.4-4 48 -. MJ00 6 2.2 4-6 72 -. MK00 0 3/4 6-0 20 3VU640 -. ML00 6 5.5/7.5 0-6 90 -. MM00 25 6-25 300 -. MN00 32 5 22-32 380 3VU640 -. MP00 40 8.5 28-40 480 -. MQ00 52 22 36-52 600 -. MR00 63-45-63 600 3VU640 -. LS00 0.76 Circuit-breakers for starter combinations No auxiliary contacts 0 with auxiliary contacts NO+NC... integrated in the circuit-breaker 2NO... 2 2NC... 3.6 0.37/0.55 without 9 3VU640 -. CG00 0.76 2.4 0.75 thermal 29 -. CH00 4./.5 overload 48 -. CJ00 6 2.2 releases 72 3VU640 -. CK00 0 3/4 20 -. CL00 6 5.5/7.5 90 -. CM00 25 300 3VU640 -. CN00 32 5 380 -. CP00 40 8.5 480 -. CQ00 52 22 600 3VU640 -. CR00 No auxiliary contacts 0 with auxiliary contacts NO+NC... integrated in the circuit-breaker 2NO... 2 2NC... 3 Note: Recommended value for standard 4-pole motors at AC50Hz 400V. /3

Accessories for 3VU 3VU9 Name Width Types Order No. Wight TE approx. =8mm kg Combinations Right hand side of 3VU: An auxiliary contact and/or a short-circuit signalling contact Left hand side of 3VU: Undervoltage release or Shunt release or Remote-controlled mechanism (for 3VU3) Auxiliary contact 0.5 Identification number Z 3VU9 3-3AA00 0.04 for 3VU3 and 3VU6 NO+NC 3VU9 3-3AA00 Short-circuit indicator switch for 0.5 Identification number Z 3VU9 3-7AA00 0.04 3VU3 and 3VU6 NO+NC 3VU9 3-7AA00 3VU9 32-0AB5 3VU9 32-0AB35 3VU9 32-0AB55 Undervoltage release AC 50Hz AC 60Hz for 3VU3 and 3VU6 230V 3VU9 32-0AB5 0. 240V -0AB25 400V -0AB7 45V -0AB8 20V -0AB23 208V -0AB24 240V -0AB26 Undervoltage release AC 50Hz AC 60Hz with two leading 230V 3VU932-0AB35 0.3 auxiliary contacts 240V -0AB45 for 3VU3 and 3VU6 400V -0AB37 45V -0AB38 20V -0AB43 208V -0AB44 240V -0AB46 Shunt release AC 50Hz AC 60Hz for 3VU3 and 3VU6 24V 3VU9 32-0AB50 0. 230V -0AB55 Permissible load duration 240V -0AB65 at DC voltage max. 5s 400V -0AB57 45V -0AB58 20V -0AB63 208V -0AB64 240V -0AB66 DC 24-60V 3VU9 32-0AB50 0-240V -0AB73 /4

Accessories for 3VU3 3VU9 Name Width Types Order No. Wight TE approx. =8mm kg Limiter to increase the short-circuit breaking capacity to 50kA at 50Hz 45V Limiter 3 Rated current n : 56A 3VU9 38-2AB00 0.29 Auxiliary contacts NO+NC 3VU9 38-2AB00 Remote controlled operating mechanism for making and breaking Remote controlled 3 AC50/60 Hz 220 to 240V 3VU9 38-AA4 0.40 operating mechanism 3VU9 38-AA4 Door-coupling rotary operating mechanisms,complete,with extension shaft Door-coupling rotary - Lockable in OFF position 3VU9 33-PA0 0.85 operating mechanism Degree of protection (black knob, IP65 grey indicator plate) Door-coupling rotary Lockable in OFF position 3VU9 33-PA02 0.85 operating mechanism Degree of protection (red knob, yellow IP65 indicator plate) /5

Accessories for 3VU Shunt trip Undervoltage release 3VU3 circuit-breaker Short-circuit signalling contact Auxiliary contact Undervoltage release with leading auxiliary contacts 3VU6 circuit-breaker Remotecontrolled operating mechanism (only for 3VU3) /6

Accessories for 3VU3 3VU9 Name Width Types Order No. Wight TE approx. =8mm kg Housings with rotary operating mechanism,front plates with rotary operating mechanism Moulded-plastic 3 Degree of protection IP54 3VU9 33-2CA00 0.25 housing +3 with N and PE terminal 3VU9 33-2EA00 0.30 +3+ Degree of protection IP55 3VU9 33-2GA00 0.32 3VU9 33-2GA00 3VU9 33-2NB00 Moulded-plastic front plate 3 A 3VU3 circuit-breaker can be 3VU9 33-2JB00 0.08 with holder snapped onto the holder Rotary operating mechanism +3+ Degree of protection IP55 3VU9 33-2NB00 0.05 for actuating the 3VU3 (front side) circuit-breaker in any housing Insulated three-phase busbar system for feeding-in several 3VU3 circuit-breakers, maximum load 63A, rated voltage 690V Three-phase busbars For 2 circuit-breakers 3VU9 35 -AB02 0.05 modular spacing 3TE For 3 circuit-breakers -AB03 For 4 circuit-breakers -AB04 0.0 For 5 circuit-breakers -AB05 0.2 3VU9 35-AB05 3VU9 35-BB00 Three-phase busbars For 2 circuit-breakers with 3VU9 35 -KA02 0.6 modular spacing 4TE aux, release or aux, contacts For 4 circuit-breakers with -KA04 0.2 aux, release or aux, contacts Three-phase feed-in Conductor sizes teminal soild or stranded: 6 to 25mm 2 connection from above finely-stranded with end sleeve: 4 to 6mm 2 Type 3VU9 35 -BB00 0.05 Type -BB0 0.03 3VU9 35-BB0 3VU9 35-BB03 Three-phase feed-in Conductor sizes 3VU9 35 -BB03 0.05 teminal soild or stranded: connection from below 2.5 to 25mm 2 finely-stranded with end sleeve: 2.5 to 6mm 2 To be snapped onto the mounting rail Cover for tags protection against shock when 3VU9 35 -GB00 0.0 the circuit-breaker is omitted 3VU9 35-GB00 /7

Accessories for 3VU6 3VU9 Name Width Types Order No. Wight TE approx. =8mm kg Door-coupling rotary operating mechanisms,complete,with extension shaft Door-coupling rotary 5 Lockabe in OFF 3VU9 63-PA0.0 operating mechanism position black knob, grey label Degree of protection IP 65 Door-coupling rotary 5 Lockabe in OFF 3VU9 63-PA02.0 operating mecbanism position red knob, yellow label Degree of protection IP 65 /8

Technical data Standards DIN VDE0660;IE947-; IEC947-2;IEC947-4- Type 3VU3 3VU6 Number of poles 3 3 Max. rated current n Plant protection A 25 63 motor protection A 25 52 starter combinations A - 52 Permissible ambient temperature at full rated current C -20 to+55 in storage C -50 to+80 Rated operational voltage U e V 690 Rated frequency Hz 50/60 Rated insulation voltage U i V 750 Rated impulse withstand voltage U imp kv 6 Utilization category to IEC947-2 (circuit-breakers) A to IEC947-4- (motor starters) AC-3 Mechanical endurance Operating cycles up to 25A 00,000 00,000 25A upwards 30,000 Number of operating cycles/h (on load) /h 25 25 Degree of protectoin with open terminals/with conductors connected IP 00/IP 20 Temperature compensation to IEC947-4- Yes Phase failure sensitivity to IEC947-4- Yes Limiter for 3VU3 Rated short-circuit breaking capacity when connected in series with 3VU3 up to AC 45V ka 50 - for other voltages See page 3 Rated operational voltage U e V 500 - Rated frequency Hz 50/60 Max. rated current n standing alone up to 55 C A 56 adjacent up to 55 C A 50 Mechanical endurance Operating cycles 00,000 Auxiliary contact Rated operational voltage U e AC V 230 400 500 Rated operational current e A 3.5 Utilization category AC-5 Rated operational voltage U e DC L/R200 ms DC V 24 60 220 Rated operational current e A 2.3 0.7 0.3 Utilization category DC-3 Undervoltage releases Power consumption during pickup VA/W 0/6 in continuous operation VA/W 4.7/2 Tripping Voltage tripping V 0.7 to 0.35 U s pick up V 0.85 to. U s Max. opening time ms 20 Shunt trips Power consumption during pickup VAW 0/6 Max. permissible command duration s - Tripping voltage V 0.7 to. U s Max. opening time ms 20 /9

Technical data Type 3VU3 3VU6 Remote-controlled mechanism for 3VU3 Rated control supply voltage U s ACV 220/240 Power consumption during pick up W 230 in continuous operation W 5 Tripping Voltage V 0.85 to. U s Minimum command duration at U s s 0.25 Max.command duration s 5 Total ON/OFF time s 0.25/0.04 Cross-section for main conductors Soild or stranded mm 2 2 ( to 6).5 to 2 6 or 25+ 0 Finely stranded with end sleeve mm 2 2 ( to 4).5 to 2 0 or 6+ 0 Cross-sections for auxiliary and control connecting leads Soild or stranded mm 2 0.5 to 2 2.5 Finely stranded with end sleeve mm 2 0.5 to 2.5 Rated short-circuit breaking capacity The table shows the rated ultimate short-circuit breaking capacity Icu and the rated service short-circuit breaking capacity Ics for the 3VU and 3VF circuit-breakers with respect to rated current In and rated operational voltage U e. Infeed is permitted at top or bottom without reduction of rated data. In the short-circuit-proof areas, Icu is at least 00 ka. A backup fuse is therefore not necessary. In the other areas, when the short-circuit current at the installation point exceeds the rated short-circuit breaking capacity given in the table for the circuit-breaker, the breaker must be protected by a backup fuse. See the following table for the maximum rated current for the backup fuse. With a backup fuse according to the table, the maximum short-circuit current is permitted to equal the rated breaking capacity of the backup fuse. Fuseless construction In fuseless construction, for the 3VU3 circuit-breaker, the limiter 3VU9 38-2AB00 is connected to the input instead of a backup fuse. This increases the short-circuit breaking capacity at AC 45 V to 50 ka. For other voltages, the values are given in brackets. Circuit- Rated Up to AC240V Up to AC45V Up to AC440V Up to AC500V Up to AC690V breakers current n cu cs Max Max Max Max cu cs cu cs cu cs cu cs Max Back up Back up Back up Back up Back up fuse fuse fuse fuse fuse (gl/gg) (gl/gg) (gl/gg) (gl/gg) (gl/gg) Type A ka ka A ka ka A ka ka A ka ka A ka ka A 3VU3 Up to A.6A Short-circuit proof up to 00kA, backup fuse is not necessary 2 2 20 2.4A 0(50) 0(50) 35 2 2 35 3.2 and 4A 0(50) 0(50) 50 3(50) 3(50) 50 2 2 50 5 and 6A 5(50) 5(50) 63 3(50) 3(50) 63 2 2 63 8 and 0A 0(50) 0(50) 80 5(50) 5(50) 80 3(5) 3(5) 80 2 2 80 3 and 6A 6(50) 6(50) 80 5(30) 5(30) 80 3(5) 3(5) 80 2 2 80 20 and 25A 0(50) 0(50) 00 6(50) 6(50) 80 5(30) 5(30) 80 3(5) 3(5) 80 2 2 80 3VU6 Up to 2.4A Short-circuit proof up to 00kA, 4A backup fuse is not necessary 4 4 80 6A 50 4 4 00 0A 50 0 5 60 4 4 25 6A 25 3 200 0 5 60 4 4 25 25A 50 25 3 200 0 5 200 4 4 60 32 to 63A 35 7 200 25 3 200 0 5 200 4 4 60 Note: ( ) Value in brackets: short-circuit breaking capacity for 3VU3 with limiter /0

Technical data Relation between short-circuit breaking capacity, related power factor and minimum short-circuit making capacity to IEC 947-2 Short-circuit breaking capacity Power factor cos ϕ Short-circuit making capacity A 3000 0.9.42 3000 4500 0.8.47 4500 6000 0.7.5 6000 0000 0.5.7 0000 20000 0.3 2.0 20000 50000 0.25 2. 50000 0.2 2.2 Characteristic curves The characteristic curves are obtained in the cold state and 3-pole loading. At operating temperature, the tripping time of the thermal releases drops by about 25%. With 3-pole loading, the deviation in tripping time for 3 times the current and upwards is 20% in accordance with DIN VDE 065. Characteristic curves for 3VU3 The characteristic curves shown here apply for a 3VU340-0MK00 circuit-breaker with a rated current of 6A, a current setting range of 4 to 6A and a tripping current for the instantaneous overcurrent release of 72A, at a rated voltage of AC 50 Hz, 400V. Schematic representation of the time/ current characteristic for 3VU3 Current limiting characteristic for 3VU340-0MK00 /

Characteristic curves for 3VU3 2 t characteristic for 3VU3 40-0MK00 Characteristic curves for 3VU6 The characteristic curves shown here apply for a 3VU6 40-0MN00 circuit-breaker with a rated current of 25A and a tripping current for the instantaneous overcurrent release of 300A, at a rated voltage of AC 50Hz, 400V. Schematic representation of the time/ current characteristic for 3VU6 Current limiting characteristic for 3VU6 40-0MN00 /2

Characteristic curves for 3VU6 2 t characteristic for 3VU 6 40-0MN00 Circuit diagrams As defined by DIN 40 73, the graphical symbols in the equipment circuit diagrams only provide information about the type, connection and operation of the devices, but not about their construction. Equipment circuit diagrams optionally attached a) Shunt trip b) Undervoltage release c) Undervoltage release with leading auxiliary contacts. d) Remote-controlled operating mechanism e) Mounted auxiliary contacts f) Additional auxiliary contacts g) Short-circuit signalling contacts h) Auxiliary contacts mounted in the limiter 3VU3 circuit-breaker and 3VU9 limiter optionally attached a) Shunt trip b) Undervoltage release c) Undervoltage release with leading auxiliary contacts. e) Mounted auxiliary contacts f) Additional auxiliary contacts g) Short-circuit signalling contacts 3VU6 circuit-breaker /3

Circuit diagrams QS Toggle handle on circuit-breaker S0 OFF button in control circuit S0 OFF S Leading auxiliary contact for 3VU3/3VU6 circuit-breakers, with 2 leading auxiliary contacts 3VU3 circuit-breakers with remote-controlled operating mechanism AC 50/60Hz, 220 to 240V, momentary-contact conmmand 5s (continuous command not permissible) Undervoltage release Shunt trip S0 OFF S Auxiliary contact of the circuit-breaker Auxiliary release for 3VU3, 3VU6. /4

Dimension drawings for 3VU (TE) (3TE) (0.5TE) (0.5TE) 3VU3 ciruit-breakers can be combined with a) undervoltage release or shunt trip and/or b) short-circuit signalling switch and/or c) auxiliary contacts 3VU9 38-2AB00 limiter The limiter has the same dimensions as the standard version of the 3VU3 circuit-breaker 35mm standard mounting rail acc.to EN 50 022 3VU9 38-AA4 remote-controlled operating mechanism Sealable hole 3VU9 33-2CA00 moulded-plastic housing Sealable hole 3VU9 33-2EA00 moulded-plastic housing /5

Dimension drawings for 3VU Sealable hole 3VU9 33-2GA00 moulded-plastic housing 3VU3 circuit-breaker Cubicle door Holder front plates with rotary operating mechanism, with holder for 3VU3 circuit-breaker 3VU9 33-2JB00, 3VU9 33-2NB00, Panel cutout Type TE a b c d e f g h i k l 3VU9 33-2JB00 3 72 90 36 52 75 60 60 53 22 40 20 3VU9 33-2NB00 5 6 00 58 90 78 00 80 53 25 5 29 /6

Dimension drawings for 3VU Type a b c d 3VU3 00 45 9 75 3VU6 30 63 45 2 3VU9.3-PA0. door-coupling rotary operating mechanism for 3VU3 and 3 VU6 3VU9 35-AB02, 3VU9 35-2AB03, 3VU9 35-AB04, 3VU9 35-AB05 three-phase busbar For 2 devices: 3VU9 35-AB02 For 3 devices: 3VU9 35-AB03 For 4 devices: 3VU9 35-AB04 For 5 devices: 3VU9 35-AB05 3VU9 35-KA02,3VU9 35- KA04 three-phase busbar with auxiliary switch or auxiliary release For 2 circuit-breakers with auxiliary switch or auxiliary release: 3VU9 35-KA02 For 4 circuit-breakers with auxiliary switch or auxiliary release:3vu9 35-KA04 removable three-phase feed-in terminal, type I 3VU9 35-BB00 three-phase feed-in terminal 3VU9 35-BB03 three-phase feed-in terminal, type II 3VU9 35-BB0 /7

Dimension drawings for 3VU a) b) c) 3VU6 circuit-breakers can be combined with a) undervoltage release or shunt trip and/or b) short-circuit signalling switch and/or c) auxiliary contacts 35mm standard mounting rail acc. to EN 50 022 Space required above arc chutes for 3VU circuit-breakers Minimum clearance with rated voltage to adjacent parts as well as non-insulated live parts. The spacing of minimum cm with 3VU3 and minimum 2 cm with 3VU6 between large-surface covers and arc openings should be observed. Uninsulated conductors must be insulated within the space required above arc chutes. 3VU3 3VU6 /8

3VU Permissible mounting position 3VU3, 3VU6 Circuit-breakers permissible mounting position due to position of the operating parts, note DIN43 602. /9