Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Similar documents
Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

FICHA TÉCNICA DE PRODUTO

TZIM. Electropneumatic Analog Positioner 10/ EN

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Field instrumentation. Electropneumatic units. as I/P converters and positioners

V200 Series Positioners

Series 3730 Electropneumatic Positioner Type

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

FieldIT TZIDC-110 Electro-Pneumatic Positioner

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

POSITIONERS and Controls for Complete Valve Automation

ABB ACTUATORS & POSITIONERS

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

V200 Series Positioners

V200 Series Positioners

Point level measurement Capacitance switches

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Type Type 1001 Transducers. I/P & E/P Transducers

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Type 4746 Electric or Pneumatic Limit Switch

Level Measurement Point level measurement - RF Capacitance switches

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

FasTrak High Capacity Smart Positioner

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Type Electronic Limit Switch

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level limit switch Series RF 3000 Selection list

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Fisher i2p 100 Electro Pneumatic Transducer

Models UP1/2/3/4/5/6/7 Universal pneumatic rotary actuators. Measurement made easy. High performance actuators for precision damper control

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Features. Flexibility

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Series Level-Trol Electronic Liquid Level Transmitters

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Miniature I/P, E/P Transducer

The EP5 electropneumatic positioner is

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Electronic Limit Switch Type

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Compact temperature switch Model TCS

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Level Measurement Point level measurement - RF Capacitance switches

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Pressure transducer DMU 01K Compact version

Kämmer Actuators Series 4 Pneumatic and Electropneumatic

Level Measurement Point level measurement - RF Capacitance switches

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

97105 Inline. Ordering information. Technical data. Accessories See page 5

Electropneumatic positioner APIS

Solenoid Valve Island Type 3965

SITRANS P measuring instruments for pressure

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Our policy is one of continued research and development. We therefore reserve the right

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

PHOENIX CONTACT - 01/2008

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

RVP-R- VAV controller. In explosion-proof version

Fisher 546 Electro Pneumatic Transducer

Mini temperature switch Stainless steel switch enclosure Model TXS

Integrated Control modules

Type 2000 Transducer Product Instructions

Solenoid Valves Type 3963

AS-I

Valve Positioners Series 760P/E Valve Positioners

Limit Switch Type 4747

Level Limit Switch liquiphant FTL 365 / FTL 366

Overview. Specifications. Applications

Junction box for EKL light

Series AV1 / 2 / 4 Characterizable pneumatic positioners

Field IT Electro-Magnetic Flowmeters Sensors

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar

Level Measurement Continuous level measurement - Capacitance transmitters

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

Continuous level measurement Capacitance transmitters

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Transcription:

Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact Design - Small dimensions, low weight Robust in terms of construction and function - Influence of shock and vibration < 1% at 10 g Wide operating temperature range - From -40ºC (optionally -55ºC) to +85ºC Various signal ranges - Input e.g. 0-20 ma or 4-20 ma - Output 0.2-1 bar or - 15 psi Complies with the following directives - EMC directive 89/6/EEC as of May 1989 - EC directive for the CE conformity certificate Various explosion protection approvals - Intrinsically safe and flameproof, with international certificate Various models - Aluminium or stainless steel field housing, IP 65 (NEMA 4X) Single Units - for OEM Applications (on request) Series I/P Signal Converters for Standard Signals without Booster Stage

I/P Signal Converter without Booster Models 22/06-66 and 22/06-67 A new variable air supply design for use with pneumatic positioners. ABB introduces an I/P configuration designed specifically for use with pneumatic positioners. The highlight of this unit is its capability to accept a wide range of air supply pressures - from 0 to 150 psi - which eliminates the need for a second regulator. All units are calibrated from stock for an 80 psi supply. Recalibration to other air supply pressures are done at no extra change. This low volume unit is engineered specifically for close mounting with penumatic positioners and provides 1/4 NPT connections for air supply and output. Integrated air filter is standard. The basic design of this unit is the same as that of our standard I/P units, so it has an inherent immunity to vibration and shock, regardless of mounting position. OEM versions are available. Consult factory for details. Press Fit Version for custom applications also available. Technical Data Input Signal range 0-20 ma or 4-20 ma Input resistance R i = 260 ohms at 20 C, T k + 0.4%/K Overload limit Capacitance/ Inductance Output Signal range Air capacity (max.) Air supply 0 ma (refer to specifications under Explosion protection for devices with explosion protection approval) negligible 0.2-1 bar or - 15 psi At supply air pressure kg/h Nm /h scfm 1.4 bar / 20 psi 0.05 0.041 0.024 2.0 bar / 0 psi 0.07 0.057 0.0 4.0 bar / 60 psi 0.10 0.082 0.048 6.0 bar / 90 psi 0.16 0.10 0.076 10.0 bar / 145 psi 0.25 0.205 0.120 Construction and mode of operation The signal converter transforms electrical into pneumatic standard signals, e.g. 4...20 ma into 0.2...1 bar or...15 psi. Instrument air free of oil, water and dust to DIN/ISO 857-1 pollution and oil contents according to Class dew point 10 K below operating temperature The patented conversion principle is based on the force-balance method and provides for small dimensions and an especially high resistance to shock and vibration. The pneumatic module was designed without an air power stage, for the benefit of small dimensions and low cost. Due to the reduced air capacity this signal converter can be used for controlling small volume systems, only. Intrinsically safe or devices with international approval certificates are available for use in hazardous areas throughout the world. Supply pressure 1.4 10 bar or 20-145 psi Air consumption equivalent to air capacity Transmission data and influences Characteristic Deviation: 1% Hysteresis: 0.% Dead band: 0.1% linear, direct or reverse action Special designs for OEM-specific mounting types are available on request. 2

Temperature 0.1% / K between -20...+85ºC 0.2% / K between -55...-20ºC Influence of Supply Air Pressure 0.8% / 1.4...2 bar / 20...0 psi 0.8% / 2... bar / 0...45 psi 0.5% /...10 bar / 45...150 psi for every 1 bar / 15 psi Mechanical vibration 1% up to 10 g and 10...80 Hz Seismic vibration Meets requirements to DIN IEC 68-- Class III for strong and strongest earthquakes Mounting orientation 0.5% at 90 change EMI complies with EMC directive 89/6/EEC as of May 1989 (increased EMI shielding to EN 50082-2 PR as of 11/9) CE Comformity Label complies with EC directive for CE conformity certification Environmental Capabilities Climate class GPF or FPF to DIN 40040 Temperature - 40...+85 C or -55...85 C Relative humidity 75% average 95% short-time non-condensing For operation in hazardous areas observe the following: 1. Max. temperature limits as specified under Explosion protection. 2. For temperatures < -20 ºC observe special mounting conditions specified in the explosion protection approval. Explosion Protection ATEX 1487X, intrinsically safe EEx ia IIC T4/T5/T6, ATEX E121X, flameproof EEx d IIC T4/T5/T6, Observe the following limits for the individual temperature classes: Temperature Short circuit Ambient Class Current (max.) temperature (max.) T6 50 ma 60º C T6 60 ma 55º C T5 60 ma 70º C T5 100 ma 55º C T5 120 ma 45º C T4 60 ma 85º C T4 100 ma 85º C T4 120 ma 80º C T4 150 ma 70º C FM intrinsically safe I.S.: CL I-II-III / Div 1 / Grp A B C D E F G N.I.: CL I / Div 2 / Grp A B C S.: CL II / Div 2 / Grp G S.: CL III / Div 2 FM explosion proof X.P.: CL I / Div 1 / Grp B C D D.I.P.: CL I II III / Div 1 Grp E F G CSA intrinsically safe I.S.: CL I / Div 1 / Grp A B C D CL II / Div 1 / Grp E F G CL III CL I / Div 2 / Grp A B C D CL II / Div 2 / Grp E F G CSA explosion proof X.P.: CL I / Div 1 / Grp B C D CL II / Div 1 / Grp E F G Other explosion protection approvals - e.g. ASEV - on request

Field housing unit Material/protection Aluminium or stainless steel housing, IP 65 (NEMA 4X) Pneumatic Connection (for air supply and output) two 1/4 NPT threads Surface Mounting Aluminium housing, varnished, two-component varnish Bottom part of housing varnished black, RAL 9005 Cover light gray, RAL 9002 Stainless steel housing Electropolished Wall mounting or 2 pipe mounting with separate stainless steel mounting bracket Mounting Orientation Weight Dimensions or 2 lateral holes for add-on module any 0.62 kg with aluminum housing 1.20 kg with stainless steel housing see dimensional drawing or add-on module for OEM application Electrical 2-pole screw terminal for 2.5mm 2 Connection in housing with with with PG 1.5 cable gland for standard, ATEX intrinsically safe M 20x1.5 thread for ATEX EEx d (on request cable gland with Ex d certificate for 9...11 mm Ø cable attached as a loose part) 1/2 NPT thread for FM/CSA 4

Dimensional Drawings 121 + - Ø 75 6 11 20 2 1 44 88 70 62 28 9 100 Aluminum or stainless steel field housing unit for wall or pipe mounting Connections (all models) 1 = Output, 2 = Air supply, Electrical connections + - 8,5 Ø 75 1,6 6,7 11 107 Ø 22 5,6 21,5 10,5 2 11 25,5 6 1 2,5 Aluminum or stainless steel field housing unit as add-on module for OEM application (Press Fit) 5

Ordering Information I/P Signal converter TEIP 11 Model No. V1812H- without booster (power) stage (01-08) 09 10 Standard (without explosion protection) Control room housing, IP 20 for rail mounting 1 1 Aluminum field housing, IP 65 for wall or pipe mounting (NEMA 4X) 1 2 Aluminum field housing, IP65 add-on module for OEM applications (NEMA 4X) 1 ATEX EEx ia IIC Control room housing, IP 20 for rail mounting 2 1 Aluminum field housing, IP 65 for wall or pipe mounting 2 2 Aluminum field housing, IP65 add-on module for OEM applications 2 Stainless steel field housing, IP 65 for wall or pipe mounting 2 4 Stainless steel field housing, IP 65 add-on module for OEM applications 2 5 ATEX EEx d IIC Aluminum field housing, IP 65 for wall or pipe mounting 2 Aluminum field housing, IP65 add-on module for OEM applic. Stainless steel field housing, IP 65 for wall or pipe mounting 4 Stainless steel field housing, IP 65 add-on module for OEM applic. 5 BRITISH Standard Ex N for Zone 2 Aluminum field housing, IP 65 for wall or pipe mounting 4 2 Aluminum field housing, IP65 add-on module for OEM applic. 4 Stainless steel field housing, IP 65 for wall or pipe mounting 4 4 Stainless steel field housing, IP 65 add-on module for OEM applic. 4 5 FM/CSA approval for "Intrinsically safe" Control room housing, IP 20 for rail mounting 5 1 FM/CSA approval for "Intrinsically safe" and "explosion proof" Aluminum field housing, IP 65 for wall or pipe mounting (NEMA 4X) 6 2 Aluminum field housing, IP65 add-on module for OEM applications (NEMA 4X) 6 Stainless steel field housing, IP 65 for wall or pipe mounting (NEMA 4X) 6 4 Stainless steel field housing, IP 65 add-on module for OEM applications (NEMA 4X) 6 5 CF = Consult factory Standard Products = 6

Ordering Information I/P Signal converter TEIP 11 Model No. V1812H- without booster (power) stage (01-11) 11 12 1 14 15 16 Input Signal 0 20 ma 1 4 20 ma 2 Output 0.2 1 bar 1 15 psi 2 Characteristic Direct-action 1 Reverse-action 2 Ambient Temperature -40...+85ºC 1-55 +85ºC 2 Air Supply (air pressure) (Refer to Stock Version Nomenclature) Adjusted to 1.4 bar (20. psi) 1 bar (4.5 psi) 2 4 bar (58.0 psi) 5 bar (72.5 psi) 4 as specified (plain text) 9 Design (varnish/label) Standard (Refer to Stock Version Nomenclature) 1 Grey (Refer to Stock Version Nomenclature) 7 OEM-specific upon request Accessories Cable gland EEx d, brass, M20 x 1.5 thread 1881-0194 Mounting bracket, stainless steel for wall mounting 1881-01944 for wall or 2" pipe mounting 1881-01945 (for mounting the aluminium or stainless steel field housing) Stock Versions Field Housing Explosion Protection Housing Input Output Without Aluminum 4-20mA -15 psi V1812H-12221127 FM/CSA Aluminum 4-20mA -15 psi V1812H-62221121 FM/CSA Stainless Steel 4-20mA -15 psi V1812H-64221141 Press Fit Explosion Protection Housing Input Output Without Aluminum 4-20mA -15 psi V1812H-1221127 FM/CSA Aluminum 4-20mA -15 psi V1812H-6221121 FM/CSA Stainless Steel 4-20mA -15 psi V1812H-65221121 Instruction Bulletin (one copy is supplied at no charge with order) 42/18-46-XA CF = Contact Factory Standard Products = 7

Notes ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com ABB Inc. 125 East County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 718 The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (1.0.06) 2006 ABB. All rights reserved. 8