APPLICATION AND SWITCH ORDERING GUIDE

Similar documents
APPLICATION AND SWITCH ORDERING GUIDE

SECTION A OIL PILOT CONTROLS

17429X.00 SERIES MODELS:

Customizing the Basic Control Handle

ELECTRIC COMPONENTS HYDRAULIC COMPONENTS

TRAC-3 TENSION READOUT AND CONTROL

AGELKOM CAP04V-9 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

EG3000. Generator Electronic Governor Controller Operation Manual

ESC2301. Universal Electronic Governor Controller Operation Manual

MODEL 115 SINGLE AXIS JOYSTICK

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

ESD5500E Series Speed Control Unit

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

CRANKCASE ASSEMBLY 5-1

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

24P Installation and Operations Manual

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

USER S MANUAL

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

CONTROL FEATURES AVAILABLE OPTIONS

Operation and Installation Manual

MCH Customizing the Basic Control Handle

Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MAINTENANCE AND PARTS MANUAL

Electric Actuators Maximum in-lbs

Electric Actuators Maximum in-lbs

Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33

2D-1. Double Driver Wiper System. Presenting the latest in single-motor, double-driver wiper technology. ,Ff- PANTOGRAPH

Damper Seal Kit Seal Kit Strainer Seal kit Seal Kit Element

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Doc. No: part_numbering_400.doc Phone (860) Dolphin Road Rev: A Date: 01/26/2007. Fax (860) Bristol, CT, 06010

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

5001TCP SPEED CONTROLLER

Vibralert Mechanical Switch Model 5550

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

EG1069X. Generator Electronic Governor Controller Operation Manual

SSC/SSCM. Stock Selector Counterbalanced Trucks

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

APS SERIES. Air Pump Shut Off Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS

DS 2400 D (EPA 3) Brushcutter. Documents DS 2400 D (EPA 3) Motor. Starter assy and clutch. Air filter. Transmission. Carburetor.

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

VALVES WITH SA ELECTRIC ACTUATOR

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

USER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

E Series Electric Actuators

# Order nr article description quantity 1 MMA chassis, drive 1 2 MMA tank, side cover 1 3 MMA handle-bars 1 4 MMA 01

FORCE SENSORS FORCE SENSORS

1.0 Features and Description

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

DC3N Non-Regenerative DC Drives

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Heavy Duty Hydrostatic Transmissions

Drawing A Crankcase 041 AV SCS

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

MODELS CMA-180/180TALL Including 480V MACHINES PARTS MANUAL Rev 2.08A

Quarter turn actuators Index

5001TCP SPEED CONTROLLER

Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Parts Catalog MIXERS

GM 6-Cylinder Cam Tool Set 3.0L and 3.2L Operating Instructions

Doc. No: part_numbering_400.doc Phone (860) Dolphin Road Rev: A Date: 01/26/2007. Fax (860) Bristol, CT, 06010

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Damper Actuator Installation

Commercial Actuator Selection Chart Non-Spring Return

Electronic Proportional (EP) Control for Heavy Duty Series 0/1 Piston Pumps Model 33 Model 39 Model 46. Model 54 Model 64 Model 76

RAPID-AIR OPERATING INSTRUCTIONS FOR RD317S, RD417M RIM DRIVE

SG1 SG1-120 SG SG Voltage Divider Output Signal

PITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

VALVES WITH SA03 ELECTRIC ACTUATOR

FS Series Motor Controller Instruction & Installation Manual

Printed from MediaCat

Haas Factory Outlet. A Division Of Trident Machine Tools, Inc. SERVO: 5907 MOTION: 242. Performance Inspection Report VMC SPINDLE: 1074

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

CATALOG OF REPLACEMENT PARTS SLICERS (INCLUDES MOTOR PARTS) A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

VALVE WITH SA ELECTRIC ACTUATOR

Installation, Operation and Maintenance Manual

Cut off saw - Starter assy and engine

ADC Series. MODULATING ELECTRIC ACTUATORS With C, CL2 & CL3 Options With N In The Model Number. Installation, Maintenance and Operating Instructions

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

AE Installation Operation & Maintenance Instructions

Fincor Series 2230 MKII/2240

Transcription:

APPLICATION AND SWITCH ORDERING GUIDE CUSTOMER: DATE: CONTACT: PHONE: FAX: 1) APPLICATION INDOOR OUTDOOR MARINE ENVIRONMENT MOBILE EQUIPMENT OVERHEAD CRANE/HOISTING CRANE CHAIR PORTABLE EQUIPMENT FOOT PEDAL OTHER 2) LER SIZE & DURABILITY MINIATURE: V10 H100 H7 V14 V20 S14 MEDIUM: V11 V8 D8 SMALL: V5 VV5 S2 S21 S22 S23 S24 N6 LARGE: V3 V6 VV6 D64 DD64 K2 3) LER FUNCTIONS SINGLE AXIS (PICK 1 OF 3 ITEMS BELLOW) DUAL AXIS MULTI AXIS STANDARD BI-DIRECTIONAL 4) SWITCH SPECIFICATIONS FULL TRAVEL UNI-DIRECTIONAL CENTER TO END UNI-DIRECTIONAL TWIST HANDLE LEFT HAND MOUNTING RIGHT HAND MOUNTING VOLTAGE AC/DC CURRENT AMPS. VOLTAGE AC/DC CURRENT AMPS. DIRECTION 1&2 DIRECTION 3&4 DIRECTION 5&6 DIRECTION 7&8 NUMBER OF CONTACTS NUMBER OF CONTACTS NUMBER OF CONTACTS NUMBER OF CONTACTS STEPLESS OR STEPS STEPLESS OR STEPS STEPLESS OR STEPS STEPLESS OR STEPS SPRING RETURN SPRING RETURN SPRING RETURN SPRING RETURN FRICTION BRAKE FRICTION BRAKE FRICTION BRAKE FRICTION BRAKE POTENTIOMETER POTENTIOMETER POTENTIOMETER POTENTIOMETER ELECTRONICS ELECTRONICS ELECTRONICS ELECTRONICS 5) ELECTRONICS A) VALVE SPECIFICATIONS VALVE MANUFACTURE MODEL NUMBER SUPPLY VOLTS: VDC COIL RESISTANCE: OHMS THRESHOLD: ma MAX. OUTPUT ma SINGLE COIL DUAL COIL FLOW SWITCHES FOR DIRECTIONAL VALVES PWM FREQUENCY: Hz B) SIGNAL OUTPUTS SUPPLY VOLTS: VDC 4-20mA 0-20mA 0-10V -10V to +10V OTHER C) OPTIONS FOR BOTH SINGLE MAX. (A ADJ.) DUAL MAX. (A & B ADJ.) DUAL RANGE ma RAMP TIME SEC. 6) HANDLE TYPE STANDARD KNOB MECHANICAL INTERLOCK PUSHBUTTON DEADMAN PUSH DEADMAN PULL DEADMAN PALM HANDLE 7) NAMEPLATE SPECIFICATIONS STANDARD NAMEPLATE 8) ENCLOSURE SPECIAL NAMEPLATE (ATTACH LAYOUT DRAWING OR SPECIFICATIONS) GENERAL PURPOSE WEATHERPROOF CORROSIVE RESISTANT (PLASTIC) PORTABLE CONSOLES ENCLOSURE DIMENSIONS L= W= H= TS1 TS2 9) NOTES TEL. (905) 564-0167 FAX (905) 564-6633

S24 SINGLE AXIS BANG BANG 3.5.1BB TEL: (905) 564-0167 FAX: (905) 564-6633

S24 PARTS LIST 3.5.4 TEL: (905) 564-0167 FAX: (905) 564-6633

S24 PARTS LIST 3.5.5 PART# DESCRIPTION 1 COMPLITE DRIVE WITH STD.HANDLE & RETURN SPRING 2 CASTING 6 PLASTIC BUSHING 9 STANDARD SHAFT ASSEMBLY 9.2 SOLID KNOB 10 STANDARD SHAFT ASSEMBLY FOR PUSH DEAD MAN 'T' 10.1 KNOB AND ROD FOR PULL DEAD MAN 'P' 11 KNOB AND ROD FOR PULL DEAD MAN 'P' 11.1 KNOB AND ROD FOR PUSH BUTTON DEAD MAN 'B' 12 STANDARD SHAFT ASSEMBLY FOR PUSH BUTTON DEAD MAN 'B' 12.1 KNOB AND ROD FOR PUSH BUTTON DEAD MAN 'B' 12.2 RUBBER CAP FOR PUSH BUTTON DEAD MAN 13 STANDARD SHAFT ASSEMBLY FOR MECHANICAL INTERLOCK 'M' 13.1 TOP KNOB,SPRING AND BOTTOM FOR MECHANICAL INTERLOCK 'M' 14 STANDARD SHAFT ASSEMBLY FOR B1T 14.1 B1T PALM HANDLE WITH ROD 15 DEAD MAN MICROSWITCH SEALED 17 RUBBER GASKET 18 RUBBER BOOT 19 MOUNTING RING NUT 20 0' POSITION PLASTIC BUSHING 21.0 SPRING 27.1 RETURN SPRING COMPLETE 27.2 RETURN SPRING COMPLETE '0' POS. IN DIRECTION 2 27.3 RETURN SPRING COMPLETE '0' POS. IN DIRECTION 1 30 TENSION SPRING STUD 31.2 TENSION SPRING OMEGA NORMAL 31.4 TENSION SPRING OMEGA STRONG 32 FRICTION BRAKE 35.1 MICROSWITCHS c/w ROLLER (0.187 TABS) 35.2 MICROSWITCHS c/w LEVER 35.3 MICROSWITCHS c/w ROLLER (0.250 TABS) 35.4 MICROSWITCHS (166) AC c/w ROLLER (SCREW TERMINALS) 36 INSULATING CIRCUIT BOARD 62 PRINTED CIRCUIT BOARD 63 POTENTIOMETER SEE SECTION 6 76 STANDARD SHAFT ASSY. FOR B5 HANDLE WITH MECH. INTERLOCK 'M' SEE PAGE 5.5.1 FOR B5 OPTIONS TEL. (905) 564-0167 FAX (905) 564-6633

S24 ELECTRONIC CALIBRATION 3.5.6 B9702-1 Dual Coil A + - X B R Single Coil Power Supply A + - AUX Valve Coil X B R Threshold Adjustment (TH) Adjust the "Threshold" Trimpot for the desired minimum speed/flow. Move the handle slowly until the LED just comes ON. If speed is too slow, turn the adjustment screw CW. If the speed is too fast, turn the adjustment screw CCW. Maximum Adjustment (Single Max) Adjust the "Maximum" Trimpot for desired maximum speed/flow when the handle is at full travel. Assure that the speed decreases when the handle is moved away from fully deflected position. Valve Coil TH Max A Max B Ramp Power Supply Flow Control A + - Power Supply AUX Valve Coil Max A X AUX A + - X B R Max B Dual Max Adjustment (Max A, Max B) See adjustment for "Maximum adjustment". Max A and Max B provide the joystick controller with separate maximum adjustments for each of the two directions. Ramping Adjusts the rate of change of output current as the handle is changing position. To increase the Ramp time, turn the adjustment CCW; to decrease the ramp time, turn the adjustment CW. To turn the Ramping completely off, turn the adjustment to minimum. (20 times CW). Dual Range Adjustment (DR) When power is applied to the R terminal, the joystick is in dual range mode. Adjust the "maximum setting" potentiometer for desired maximum current when the handle is deflected to its full travel position. Assure that the speed decreases when the handle is moved away from fully deflected position. Voltage: 12VDC 24VDC CW Clockwise CCW Counter-Clockwise TEL: (905) 564-0167 FAX: (905) 564-6633

S21 PARTS LIST 3.2.4 TEL: (905) 564-0167 FAX: (905) 564-6633

S21 PARTS LIST 3.2.5 S2 S22 S24 DESCRIPTION 30 29 22 SHAFT ASSEMBLY FOR B_ 14 15 23 METAL FLANGE PLATE 25 22 24 PLASTIC FLANGE PLATE 28 28 25 RUBBER BOOT 86 91 67 OVAL HEAD SCREW M5x15 87 90 68 FLAT HEAD SCREW M5x12 TEL. (905) 564-0167 FAX (905) 564-6633