Temperature Sensor without thread

Similar documents
Continuous level sensor NSK

Compact Pressure Transmitter DAN-HH

Continuous Level Sensor NSL-F

Continuous level sensor NSK

Digital Pressure Gauge / Pressure Switch

Level Sensor with M12 Thread Hygienic

Level Sensor with G1/2" Thread Hygienic

Mini Pressure Transmitter HA7

Continuous level sensor NSL-F-00, -01, -02

Ultrasonic flow switch FWS-141, FWA-141

Modular Pharma Pressure Transmitter MPP

Conductive Multilevel Sensor

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Hygienic, Elastomer- and Gap Free Process Connections

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Digital ph transmitter

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

Digital ph transmitter

Screw-in resistance thermometers with plug connector

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Temperature sensor TE2

Resistance thermometer Model TR10-E, for additional thermowell

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Modular Pressure Transmitter PF

JUMO dtrans p20 DELTA

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

- Quicktemp TP62/TW39...T500 -

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Magnetic-Inductive Flow Meter FMI

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

CombiTemp Temperature Measuring System

Magnetic-Inductive flow Meter fmi

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Manual Electronic Identification Systems BIS Read/Write Heads C3-slk_716464_E_1110.p65 Deutsch bitte wenden!

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Paddle-wheel flow controller for On/Off control

Pressure transmitter PASCAL CV4

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

RTD Temperature Sensor omnigrad M TR 47, TR 48

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Measuring insert for resistance thermometer Model TR10-A

SATRON VTe pressure transmitter

SATRON VDt Differential Pressure Transmitter

Magnetic switch For bypass level indicators Model BGU

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Magnetic-Inductive Flow Meter FMQ

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

SATRON VVFe Pressure Transmitter

Electronic Temperature Sensor ETS 300

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

SATRON VT Pressure Transmitter

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

JUMO MIDAS Pressure transmitter

Differential Pressure Sensors

Inductive conductivity meter

JUMO MIDAS S05 Pressure transmitter Type

Flush-mounted pressure and level transmitters - KERAMESS KS S 200/201 - Superior Precision

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Inductive conductivity meter

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Turbine flowmeter HM-E / HMP-E

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

AKM 105, 115: Rotary actuator for ball valve

Flush-mounted pressure and level transmitters - KERAMESS KS series 100/101 -

AVM 105, 115: Valve actuator

OPTISWITCH 6500 C Technical Datasheet

SITRANS P measuring instruments for pressure

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Temperature sensors. and accessories for heat and cooling measurement points. Applications. Benefits. Features

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

INSERTION flow sensor for continuous flow measurement

RTD Temperature Sensor omnigrad M- TR 11

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Proximity switches and switch brackets

HUMIDITY / TEMPERATURE TRANSMITTER

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Capacitive level sensors CLS 23

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Pressure Transmitter

CombiTemp Accessories

Thermal flow sensor TFS-35

Resistance thermometer Without thermowell Model TR10-H

Transcription:

1 Product Information TFP-49, -169, -189, -06 Temperature Sensor without thread Application / Specified Usage Authorizations Installation in thin-walled pipes and vessels No product contacting of the sensor (with thermowell) Demounting the sensor without opening the process Application Examples Process monitoring in pipes Temperature measurement in pressure pipes Measurement of paste products in pipes Temperature Sensor TFP-49 Hygienic Design / Process Connection Hygienic and easy sterilizable installation by weld-in sleeve (e.g. EMK-25/76) or weld-in thermowell (e.g. ESH-KM12/...). By elastomer free sealing system the connection is free of gaps and crevices CIP- / SIP-cleaning up to 140 C Product contacting materials compliant to FDA Sensor and head completely made of stainless steel Features Variable insertion depths Integrated transmitter (optional) Different types of electrical connections possible Options / Accessories 2 x Pt100 (not retrofittable) Programmable transmitters MPU-4 and MPU-M with output 4...20 ma, 2-wire Integrated transmitters for Profibus PA and HART-protocol Programming adapter MPU-P 9701 Integrated transmitter MPU-LCD with display in connecting head Pt100 chip with other classes of accuracy (1/3B, 1/10B) Fast response sensor tip 3 mm and 4 mm Pre-assembled connecting cable for M12 plug Fixed cable in other lengths and material available Temperature Sensor TFP-169 with Transmitter MPU-M

Specification 2 Temperature Sensor Process connection gap-free with weld-in sleeve, e.g. EMK-25/76 or weld-in thermowell, e.g. ESH-KM12/... Insertion length EL standard 50...500 mm Materials connecting head stainless steel 1.4305 thermowell stainless steel 1.4404 Operating pressure with weld-in sleeve 10 bar maximum with weld-in thermowell 50 bar maximum Temperature ranges ambient -50...+85 C sensor tip -50...+250 C Sensing resistor acc. to DIN EN 60751 Pt100 Electrical Connection cable gland M16 x 1,5 cable connection M12 plug 1.4305, 4-pins fixed cable 2,5 m LIYY 4 x 0,25 mm² fixed cable (> 90 C) PTFE 4 x 0,14 mm² Protection Class TFP-49, -169, -189 IP 69 K (with electrical connection M12 plug) TFP-06 IP 68 Transmitter MPU-4, MPU-10, MPU-H, MPU-M Temperature ranges ambient -40...+85 C storage -55...+90 C Measuring ranges MPU-4, MPU-H, MPU-M standard: -10...40 C, 0...50 / 100 / 150 / 200 C special ranges free programable MPU-10 standard -200...850 C configuration occurs with Profibus Accuracy < ±0,25 C Temperature drift zero, span < 0,01 % / K Supply MPU-M, MPU-4 8...35 V DC MPU-10 9...32 V DC Output signal analog 4...20 ma (not for MPU-10) accuracy < ±0,1 % of measurement range burden < 600 Ω (at U B = 24 V) Humidity without condensation 0...98 % Accuracy classes of temperature sensors Tolerances for Pt100 acc. to DIN EN 60751 Pt100 A 1/3 B 1/10 B 0 C / 100 Ω ±0,15 K / ±0,06 Ω ±0,10 K / ±0,04 Ω ±0,03 K / ±0,01 Ω 100 C / 138,5 Ω ±0,35 K / ±0,13 Ω ±0,27 K / ±0,10 Ω ±0,08 K / ±0,03 Ω

3 Electrical Connection Electrical connection without transmitter Electrical connection with transmitter With 1 x M12 plug Config. 1st M12 plug M12 plug Configuration M12 plug bk bn bu wh 1 2 3 4 bk bn bu wh 1. + supply 2. - supply 4...20 ma 3. not connected 4. not connected With 2 x M12 plug Config. 2nd M12 plug bk bu 1 2 3 4 bn wh With cable gland With cable gland Config. strip terminal 1 2 3 4 PLC 4...20 ma current-loop clamps for 1st Pt100 clamps for 2nd Pt100 (at version 2 x Pt100) Pt100 With fixed cable Fixed cable connection with 1 x Pt100 wh ye rd rd bn gn standard wh wh PTFE Pt100 Fixed cable connection with 2 x Pt100 (LIYY) Fixed cable connection with 2 x Pt100 (PTFE) wh ye rd bu bn gn 1st Pt100 pk gy 2nd Pt100 rd rd vt vt wh 1st Pt100 ye 2nd Pt100 Pt100 Pt100

Dimensioned Drawings 4 TFP-49 TFP-49.2 TFP-06 3 m (standard) TFP-169 TFP-169 /... / MPU-M TFP-189 TFP-189.2

5 Dimensioned Drawings Sensor tip diameter and response time All temperature sensors are available with smaller sensor tips, to ensure a shorter response time. The below-mentioned times were measured by immersing a temperature sensor with room temperature into boiling water. Sensor tip Ø 6 mm with thermowell Sensor tip Ø 6 mm Sensor tip Ø 4 mm Sensor tip Ø 3 mm validity: t 50 8,8 s 90 %-time: t 90 24,5 s validity: t 50 3,0 s 90 %-time: t 90 8,0 s validity: t 50 2,4 s 90 %-time: t 90 6,5 s validity: t 50 0,5 s 90 %-time: t 90 1,5 s Ø6 Ø6 Ø6 Ø6 Ø8,8 Ø4 Ø3 Note When using weld-in thermowells we recommend to use heat-conductive paste too. This can reduce the response time up to 50 %.

Warnings Option MPU-LCD 6 Mechanical Connection / Installation Check the compatibility of the sensor to the used immersion sleeve. Conventional Usage Not suitable for applications in explosive areas. Not suitable for applications in security-relevant equipments (SIL). Transport / Storage No outdoor storage Dry and dust free Not exposed to corrosive media Protected against solar radiation Avoiding mechanical shock and vibration Storage temperature -55...+90 C Relative humidity maximum 98 % Reshipment Sensors shall be clean and must not be contaminated with dangerous media! Use suitable transport packaging only to avoid damage of the equipment! Cleaning / Maintenance In case of using pressure washers, dont t point nozzle directly to electrical connections! Standards and Guidelines You have to comply with applicable regulations and directives. Disposal This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Pass the instrument directly on to a specialised recycling company and do not use the municipal collecting points. Advice to EMC The device agrees to following standards: EMC directive 2004/108/EC. You have to guarantee the EMC directives for the entire equipement. Temperature Transmitter MPU-LCD with Display Application / Specified Usage 4...20 ma transmitter with LCD for Pt100 temperature sensor For installation in temperature sensor Sensor monitoring Option MPU-LCD (display in the connection head) Features 4-digit display with green backlight Temperature measurement in C and F Easy range select by one button Lower costs for wiring because of 2-wire technology Note: See product information MPU-LCD for details.

7 Order Code Order Code for version with 1 x Pt100 TFP-49 TFP-169 TFP-189 TFP-06 TFP-06-IP68 (temperature sensor with connecting head Ø 55 mm) (temperature sensor with head Ø 18 mm, electrical connection M12 plug) (sensor with head Ø 18 mm, electrical connection 2,5 m PVC-cable; no transmitter possible) (sensor without connecting head, with 3 m PVC-cable, other lengths: on request) (sensor without conn. head, prot. cl. IP 68, with 3 m PTFE-cable, other lengths: on request) Sensor length EL in mm 050...250 xxx (special length) Diameter thermowell in mm 6 8 10 12 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm; no extra charge for sensor length 20 mm) 6 (only for thermowell 8 mm and 10 mm) 8 (only for thermowell 12 mm) Accuracy Class A 1/3B 1/10B Electrical connection (not selectable at TFP-169, -189, -06 and -06-IP68) PG (cable gland M16x1,5) M12 (M12 plug 1.4305, standard with MPU-LCD) Transmitter X for TFP-49 MPU-4 MPU-10 MPU-H MPU-LCD for TFP-160 MPU-M (without) (programmable) (Profibus PA) (HART-protocol) (with display) (programmable) Measuring Range (only for types with transmitter; not at MPU-LCD) -10...40 C 0...50 C 0...100 C 0...150 C 0...200 C xx...yy (special range) TFP-49 / 100 / 6 / 6 / A / M12 / MPU-4 / 0...100 C

Product Information TFP-49, 169, -189, -06 8 Order code for version with 2 x Pt100 TFP-49.2 TFP-189.2 (temperature sensor with connecting head Ø 55 mm, 2 x Pt100, no transmitter possible) (connecting head Ø 18 mm, electrical connection 2,5 m PVC-cable; no transmitter possible) Sensor length EL in mm 050...250 xxx (special length) Diameter thermowell in mm 6 8 10 12 Diameter sensor tip in mm X (no reduction) 3 (only for thermowell 6 mm) 4 (only for thermowell 6 mm and 8 mm; no extra charge for sensor length 20 mm) 6 (only for thermowell 8 mm and 10 mm) 8 (only for thermowell 12mm) Accuracy class Pt100 A 1/3B 1/10B Electrical connection only for TFP-49.2 PG (cable gland M16x1,5) 2 x PG (2 x cable gland M16x1,5) 2 x M12 (2 x M12 plug) TFP-49.2 / 100 / 6 / 6 / A / M12 Note Versions with 2 x Pt100 and two transmitters you will find in product information TFP-69. Accessories PVC-cable with M12-connection PVC-cable with M12-connection made of 1.4305, IP 69 K, unshielded M12-PVC / 4-5 m M12-PVC / 4-10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 5 m PVC-cable 4-pin, length 10 m PVC-cable 4-pin, length 25 m PVC-cable with M12-connection, brass nickel-plated, IP 67, shielded M12-PVC / 4G-5 m M12-PVC / 4G-10 m M12-PVC / 4G-25 m PVC-cable 4-pin, length 5 m PVC-cable 4-pin, length 10 m PVC-cable 4-pin, length 25 m Programming adapter MPU-P 9701 Programming adapter MPU-P 9701 Programming adapter for MPU-4, MPU-H and MPU-M 04.11.10 / 6.0 / MU / at-ac.de