HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

Similar documents
SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Diesel Engine Shutdown Valves

MVX-Series Diesel Engine Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Diesel Engine Shutdown Valve

Solenoid Actuated Diesel Engine Air Shut Down Valves

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SELECTION, APPLICATION AND MAINTENANCE

Air Intake Shut-off Valve

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Diesel Engine Shutdown System

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

SELECTION, APPLICATION AND MAINTENANCE

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

E Series. Automatic Engine Overspeed Shut Down Valves

Automatic Fuel Shut Down Valves

System Selection Guide

Flameproof Alternators

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Diesel Engine Air Intake Shutoff Valves

Intake Air Shut-off Valve

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Pilot Operated 2-Way Gas Valves

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

by AMOT World class diesel engine safety solutions Product Selection Guide

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Metal Particle Detector

Thermostatic Control Valves

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

Optimise your temperature control

Pressure and Temperature Switches

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

2-Way Temperature Sensing Valves

Pneumatic Indicating Relay

Is the heart of your engine protected?

3-Way Temperature Control Valve

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

Flameproof Alternator

Thermostatic Control Valve

E1186X Breather Kit. For Yanmar L48N Engines

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

Thermostatic Control Valve

Flameproof Alternator

Model E. Thermostatic Control Valves. Typical applications

Self-Exciting Flameproof Alternator

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Flameproof Alternator

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Bulk Liquid Filtration

type 122a three-way Switching Valve

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Metal Particle Detector

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)

T205VB Series Tank Blanketing Vacuum Breakers

M High Performance Power Transmission Couplings

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

Type 289P Pilot-Operated Relief Valve

BARTON 7000 Series Liquid Turbine Meters

SEries 41 check valve installation, operation & maintenance manual

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

289 Series Relief Valves

Marine. Series 2000 Diesel Engines for Marine Applications

JAMESBURY EASYFLOW JT SERIES ANGLE STEM TANK BOTTOM VALVES

SI unit. Supplementary unit unit. in Ib Ibf Ibfft psi qt(us) F. kg N Nm bar 1 C

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Thermostatic Control Valve

type 630r relief Valve

Installation Instructions

25198:- 1/31/12 11:24 AM Page 2 Filtration Systems

IMO-200EN 09/2010. Trunnion mounted forged ball valves Model FF and GG. Installation, Maintenance and Operating Instructions IMO-200EN 09/2010

Engineering Standard. Fig 707 Safety Relief Valve Installation and Maintenance Instructions

WHEATLEY Dual-Plate Wafer Check Valve. Space-saving design with a full bore for improved flow characteristics in backflow prevention applications

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

Type 310A-32A Pressure Reducing Regulator

Unequalled kinematics

reliable actuators to

Liquid Turbine Flowmeters

Bulletin: Floating Ball Valve. Tartarini Floating Ball Valve. Introduction. Features and Benefits

167D Series Switching Valves

Operating Instructions

Transcription:

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop) Selection, Application and Maintenance Valve Numbers HVX-300 HVX-500

DESCRIPTION Based on the Chalwyn 3 and 5 slimfit butterfly types these air intake shut down valves are designed to be latched open by engine oil pressure. Manual start override is via a cable from a remote lever assembly (RLX-100). Once the engine is running the valve is held in the run position by lubricating oil pressure. Valve closure will occur if the oil pressure drops below about 20psi (1.4bar). Emergency manual stop is by returning the lever RLX-100 to the stop position. HVX-300 and HVX-500 valves are suitable for both hazardous and non-hazardous area applications. They are available in basic flange mounted form or fitted with hose adaptors and/or flametrap housing. Valve body and disc are manufactured in corrosion resistant hard anodised aluminium. The valve spindle is in 316 stainless steel. Typical HVX Valve Arrangement C2 (Max) B1 C2 (Min) C1 Optional hose adaptors B Oil pressure input A Start override/manual emergency stop cable Thread connection Illustration based on HVX-300 Main Dimensions () Valve Type Nominal Bore Diameter A B B1 C1 C2 minimum & maximum HVX-300 76 (3 ) 213.5 111.5 144 37.5 82.5 to 112.5 HVX-500 127 (5 ) 270 167 171.5 45.5 102.0 to 157.5 Note: Maximum temperature of the engine intake air at the HVX valve not to exceed 150 C. (See also Installation - Page 4). page 2

SELECTION Determine the size and position of the HVX valve to be installed. Within the various constraints imposed in the application the valve should be as generously sized as possible. The length of the start override/manual stop cable needs to be determined. The start override lever (RLX-100) should be positioned where both convenient for operating and also from where a direct cable run to the valve with a minimum of tight bends if possible. The HVX range of valves are designed for flange mounting but can also be supplied fitted with hose adaptors selected form the table below. Hose Adaptor Options 76 (3 ) Bore Valves Adaptor To Suit Hose Bore Part Number (inches) HAX-320 38 ( 1 1 / 2 ) HAX-322 44.5 (1 3 / 4 ) HAX-301 51 (2) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-309 76 (3) HAX-312 82.5 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 127 (5 ) Bore Valves Adaptor To Suit Hose Bore Part Number (inches) HAX-501 89 (3 1 / 2 ) HAX-503 95 (3 3 / 4 ) HAX-505 102 (4) HAX-507 108 (4 1 / 4 ) HAX-509 114 (4 1 / 2 ) HAX-511 121 (4 3 / 4 ) HAX-513 127 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) Override Cable Options (other lengths may be available on request) Cable Identity Cable Length CHW-100 1.0m CHW-200 2.0m CHW-250 2.5m CHW-300 3.0m page 3

INSTALLATION 1. In the case of a naturally aspirated engine, the Chalwyn HVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an intake flame trap is also fitted, the HVX valve must be installed upstream (air cleaner side) of the flame trap. 2. To avoid excessively high intake air temperatures at the HVX valve when fitted to a turbocharged engine, it may be necessary to fit the valve either upstream of the turbocharger or downstream of the intercooler (if fitted). Again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. HVX intake shut down valves may be installed either horizontally or vertically. 4. If hose adaptors are used, the mating hose should be of a re-inforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 5. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. The possibility of a hose collapse on closure of the shut down valve should be avoided. 6. Any engine crankcase breather connections into the intake system between the HVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. 7. The lever assembly RLX-100 should be mounted using the three through holes provided in the assembly. It must be positioned where convenient for operation but also such that a reasonably straight run without tight bends if possible for the override cable run between the lever assembly and valve. 8. The lever RLX-100 is sprung towards the valve closed position. With no oil pressure applied the HVX valve is also sprung to the closed position. With both the RLX-100 and HVX valve in the closed position fit the override cable. Adjust cable and tighten the locknuts such that with the HVX valve fully closed, the end of the lever RLX-100 is positioned about 5 to 10 from its central stop (closed) position. When the RLX-100 is exercised over its operating stroke the distinct sound of the HVX valve closing should now be audible. page 4

OPERATION 1. Prior to starting engine use the start override lever to open the HVX valve to the run position. 2. Continue to hold the valve in the run position whilst starting and running up engine. 3. Once engine has run up, the engine oil pressure will latch the HVX valve in the run position. The override lever may then be released and should remain in the run position. 4. Should engine oil pressure at the HVX valve fall below about 20psi (1.4bar) the HVX will close and stop the engine. MAINTENANCE MONTHLY: Check that the fasteners locating the HVX valve and any associated intake system or support bracket fasteners are tight. Check that any flexible hoses in the air intake system between the HVX valve and engine are free from damage and suitable for further service. Check that the oil pressure pipe to the HVX valve is properly supported, free from damage and that the pipe fittings are tight and leak free. 5. To carry out a manual emergency stop, move the start override lever from the run position back to the stop (valve closed) position. Start engine. Run at or just above low idle speed. Carry out a manual emergency stop. The engine should stop within a few seconds of moving the start override lever from the run to stop position. If not: a) Check then engine air intake system for freedom from leaks. b) Check that the start override cable is properly adjusted. Should these checks not resolve the problem return the HVX valve to Chalwyn for inspection. page 5

NOTES: page 6

Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghai@amot.com AMOT - Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com DS-HVX-300-500-ShutdownValves-CE229-0712-rev1 www.chalwyn.com by AMOT