Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

Similar documents
PRODUCT MANUAL. CARBONATE REMOVAL DEVICE 200 CRD 200 (4 mm) (P/N ) CRD 200 (2 mm) (P/N )

EGC II K 2 CO 3. Cartridge Electrolytic ph Modifier EGC Carbonate Mixer

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start

Dionex CRD Carbonate Removal Device

For new orders of the following parts discussed in this manual, please use the updated part numbers listed below.

S 1125 HPLC Pump System

850 Professional IC. AnCat MCS Manual EN

The Measure of all Things. Volumetric Solutions from Merck

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Combustion ion chromatography with a Dionex Integrion HPIC System

881 Compact IC pro. 881 Compact IC pro Anion MCS. Manual EN

using Diesel exhaust fluid with the duramax 6.6L turbo-diesel

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

754 Dialysis Unit Instructions for Use / dö

Cold Vapor Mercury Apparatus* Purpose Figure 1 Cold Vapor Mercury Apparatus Assembly Overview

Agilent 1200 Series Manual Injector

HPLC System S 600 Series

LC30 CHROMATOGRAPHY OVEN OPERATOR S MANUAL Dionex Corporation

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation

Bright prospects Solvents for spectroscopy Uvasol

HIGH PRESSURE SWITCHING VALVES

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

833 IC Liquid Handling Unit

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

ÄKTA system Training Guide. Purifier 100 / 10. amersham bio science

Fixed Flow Splitter *

Agilent G5632 Valve Kit Instructions

QuickSplit TM Flow Splitters

For ELECTRONIC INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit

GlycoChrom TM HPLC Analyzer. Hardware Installation and System Test

2016 Isuzu Truck 23.1

Agilent Dynamax Analytical HPLC Column Systems 4.6 mm id Data Sheet

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GE Healthcare. Valve INV-917. Instructions

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

This convenient system is made entirely of inert parts: glass, Baseline drift

Safety Data Sheet. Lithium-Ion Rechargeable Battery Pack BL1840

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

BlueSwan Pipette Controller

FITTINGS, LOOPS, AND VALVE ACCESSORIES

HPLC SYSTEM S 500 SERIES

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Engine oil. Introduction. Warning and indicator lights WARNING

Setting up SilFlow for BackFlush in your GC

Valving Schemes for the BioLogic Duo-Flow Chromatography System

Uytengsu Teaching Center Chemical Reactor Standard Operating Procedure

Agilent Valve Kit G4231A/B and G4232A/B/C

DynaLoop 25 and DynaLoop 90. Instruction Manual

RAPID OIL TEST GAUGE

INSTRUCTION MANUAL WaterStep M-100 Chlorine Generator

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

NEW HPLC - SYSTEM LINE

Motor Valve MV-7/IMV-7

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

OWNER S MANUAL FOR THE PROTECTEAT TEAT SPRAY SYSTEM

4025 Synthesis of 2-iodopropane from 2-propanol

4001 Transesterification of castor oil to ricinoleic acid methyl ester

HPLC Tubing and Fittings Hints & Tips for the Chromatographer

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

GE Healthcare. ÄKTApilot. User Manual

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

Battery Information Sheet

MODEL 905V OPERATING INSTRUCTIONS

[ CARE AND USE MANUAL ] WATERS ADVANCED PURIFICATION COLUMNS I. INTRODUCTION CONTENTS I. INTRODUCTION II. USING THE COLUMN III. CARE AND MAINTENANCE

INSTRUCTIONS. SILEX demineralizers. Type 1 B and 2 B. Our World is Water. D1A-30Bver4. Instructions. SILHORKO-EUROWATER A/S Phone

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

This chapter describes how to perform periodic inspection and maintenance to ensure the long operating life of the chamber.

PHscan10S Pocket ph Tester Instruction Manual

Light condition and operation Windshield glass condition Wiper blade condition Paint condition and corrosion Fluid leaks Door and hood lock condition

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

Determination of Sudan Dyes I IV in Curry Paste

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Agilent 1260 Infinity Manual Injector

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Operation Manual BOTTLE TOP DISPENSER

ReciPro Liquid Metering Pumps. Reproducible flow rates High pressure capabilities Corrosion resistant Remote control options

Instrumentation of HPLC. HPLC Solvent Pumping Systems

JADE Bottle Top Dispenser

Dual Flow Manifold Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual

UCT VACUUM EXTRACTION MANIFOLD

Agilent Valve Kit G4231A/B/C and G4232B/C/D

THC Heated FID 3-300A

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

Filters & Frits. IDEX Health & Science introduces Upchurch Scientific precolumn and inline very high pressure (VHP) filters on page 159

C OMPONENT S F O R A C L O S E D - S YS T E M HPL C

Dosage Pumps - Installation Guide

Assembly instructions

Operation Manual. Pipette Aid. Concorde Liquid Handling Equipment. *This instrument is intended for laboratory use only.

XpressFill XF460/XF260

IMPORTANT INFORMATION

Liquid Handling Station

#9040 FUEL TANK SWEEPER

Totally Automated Method for the Determination of Sudan Dyes in Food via On-Line Filtration, SPE and HPLC Analysis

Printed: Doc-Nr: PUB / / 000 / 00

Plunger Heads Use and Maintenance Manual

Transcription:

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System for SeQuant SAMS Suppressors

Instructions for Use SeQuant CARS Continuous Auto-Regeneration System CONTENTS General Information... 2 Unpacking... 3 Installation... 4 Diluting the ULB -P Regeneration Solution... 4 Operating the Pump... 4 Safety Check Valve... 4 Cutting the Tubing... 5 Installing and Filling the Cartridge... 5 Starting the CARS System with a SAMS Suppressor... 6 Operation... 7 Optimum Performance... 7 Cartridge Expansion Tubing... 7 Air Bubbles... 7 SAMS Suppressor... 7 Temporary Storage... 8 Expected Cartridge Lifetime... 8 Disposal of CARS Cartridges... 8 Disposal of ULB -P Regeneration Solution... 8 Disposal of SAMS Suppressors... 9 Pump Maintenance... 9 Reordering Information... 9 A Practical Guide to Ion Chromatography... 9 www.sequant.com/cars chromatography@merckgroup.com

Instructions for Use - SeQuant CARS General Information The SeQuant CARS system is designed to minimize the eluent background conductivity in anion chromatography and is used in combination with the SeQuant SAMS membrane suppressor. The robust and flexible design of CARS ensures stable routine operation together with many different brands of ion chromatography systems and conductivity detectors. Separation Column Precolumn CARS TM Continuous Anion Regenerant System Injector Eluent purifier Cartridge Regenerant Pump SAMS TM SeQuant Anion Membrane Suppressor Detector Eluent Pump Waste Figure 1: Schematic drawing of the system set-up when the SeQuant CARS is used together with the SeQuant SAMS for continuous chemical suppression in anion chromatography. The CARS system acts by maintaining a constant acidic environment in the SAMS suppressor, where the ion chromatography eluent background conductivity is suppressed. Protons continuously supplied from the CARS cartridge to the SAMS suppressor are transported across the suppressor ion exchange membrane into the eluent. There protons replace the cationic counter ions in the eluent (often sodium or potassium), thereby neutralizing the eluent ions to their corresponding acids (often carbonic acid or water) which have very low conductivity. The replaced eluent cations are transported out from the SAMS suppressor and deposited on the CARS cartridge. Anions on the other hand, cannot cross the suppressor membrane due to ion exclusion. The SeQuant ULB -P regeneration solution circulating in the CARS system is an ultra-pure organic acid that act as a vehicle for transport of protons between the CARS cartridge and the SAMS suppressor. The CARS system with SAMS suppressor is particularly well suited for applications requiring long, unattended routine operation, and exceptionally low and stable background conductivity. Gradient elution may also be carried out with minimal baseline drift, and the background level is unaffected if the user decide to change the mobile phase flow rate or ion strength to reduce the chromatographic run time. While convenient and cost-saving in laboratory applications, the SeQuant CARS will really excel in applications such as environmental sampling in pristine areas, and for continuous industrial monitoring of high purity water.

Instructions for Use - SeQuant CARS 3 Figure 2: Ion exchange in a SeQuant SAMS TM suppressor connected to SeQuant CARS TM for continuous regeneration Unpacking The SeQuant CARS system shipment contains the following parts: CARS Pump, mounted on stand designed to hold the cartridge (1 ea) Suppressor Installation Kit (1 ea) Reorder number: 1.50619.0001 CARS Cartridge Small, 0.5 L (1 ea) Reorder number: 1.50613.0001 ULB -P Regeneration Solution (1 ea, 100 ml) Reorder number: 1.50616.0100 Spare Safety Check Valves 2 bar, 30 psi (2 ea) Instructions for Use (1 ea) Please confirm the delivery against the list above. Figure 3: SeQuant CARS Cartridge (left) and SeQuant SAMS Suppressor (right). SAMS is sold separately.

Instructions for Use - SeQuant CARS Installation Diluting the ULB -P Regeneration Solution Wear protective glasses and gloves during handling of the ULB -P Regeneration Solution. The SeQuant ULB -P Regeneration Solution contains an ultra-pure, high-molecular weight, polymeric sulfonic acid, which may be corrosive and irritate skin and and spills should therefore be avoided. The use of eye protective glasses and gloves during handling is strongly recommended. The ULB -P is shipped as a concentrate and shall be diluted 1+4 with Reagent Grade Laboratory Water before use. Transfer all 100 ml of the supplied ULB -P to a 500 ml flask. Add and dilute with 400 ml Reagent Grade Laboratory Water. Mix the solution properly. Diluted ULB -P that is not used immediately should be stored in a plastic bottle in a cool place (ca 5-10 C), but not below freezing. Reagent Grade Laboratory Water is ultra-pure deionized water, free of organics, microorganisms and particulate, with a specific resistance of 18 Mohm cm -1. Do not use water on bottle unless this is optimised for ion chromatography and do not contain high levels of ions. Contamination of the ULB -P with ions will deteriorate the low background capability of the ULB -P solution and decrease the performance of the CARS System. Operating the Pump To avoid damaging the CARS Pump, only change the flow rate when it is in operation. There are two controls on the pump front: I. The top button mechanically adjusts the volume delivered per pump stroke and should only be used when the pump is operating. This button is used to alter the flow rate of ULB -P and is normally set to a value of 80. II. The lower button is the power switch. Use this switch to turn the pump on and off. Figure 4: Control buttons on the CARS Pump. Safety Check Valve Install the Safety Check Valve (2 bar, 30 psi) at the top of the Pump outlet. This will protect the user against overpressure that could occur if the tubing in the system is accidentally blocked or squeezed. Connect the outlet of the Safety Check Valve to the Expansion Flask (EF), which should be able to hold all the ULB -P in the system (~150 ml). A triggered Safety Check Valve is damaged and need to be replaced. Figure 5: Install the Safety Check Valve and connect its outlet to the Expansion Flask (EF).

Instructions for Use - SeQuant CARS 5 Cutting the Tubing The tubing in the Suppressor Installation Kit should be cut with scissors into five pieces of suitable lengths. Two pieces should be long, about 1.5 m (5 ft) each, whereas the other three should be short, about 0.5 m (1.5 ft). Attach the six Luer Connectors to the two long tubing and one of the short. Use the two longer tubing to connect the suppressor and the other for connecting the Pump to the Cartridge. The remaining short pieces of tubing are used from the Safety Check Valve and the Cartridge Vent to the Expansion Flask or waste. Installing and Filling the Cartridge CARS Cartridges are delivered empty and must first be filled with diluted ULB -P. The CARS Pump is used for this procedure and it involves some temporary plumbing, according to the steps listed below and as shown in Figure 6. Wear protective gloves and glasses when performing the filling procedure. Figure 6: Tubing connections for filling the CARS TM Cartridge. Tubing D is connected from the exit of the Safety Check Valve. 1. Install the Cartridge in the holder at the rear of the Pump. 2. Remove the two Luer Plugs from the inlet and outlet of the Cartridge, but let the vent be plugged during the filling. 3. Connect a short tubing (A) to the Pump inlet (bottom) and place the other end of the tube in the flask containing the diluted ULB -P. 4. Connect a long tubing (B) between the Pump outlet (top) and the Cartridge outlet (centre). 5. Connect a long tubing (C) to the inlet (edge) of the Cartridge and place the other end in a suitable waste bottle. 6. Connect a short tubing (D) from the exit of the Safety Check Valve to a waste bottle. 7. Start the Pump and let it operate until about 250 ml of the diluted ULB -P has emerged to waste. Save the remaining approx 150 ml of diluted ULB -P for future refilling needs. Store it in a plastic bottle cold, but not below freezing. 8. Stop the Pump. Figure 7: Connections on the CARS Cartridge.

Instructions for Use - SeQuant CARS Starting the CARS System with a SAMS Suppressor Before you start the CARS Pump for normal operation, ensure that the connecting tubing are assembled correctly. Figure 8: Tubing connections during normal operation the CARS TM System. Tubing D and E are connected to the Expansion Flask (EF) from the exit of the Safety Check Valve and from the Cartridge Vent, respectively. 1. Connect a long tubing (A) between the SAMS Suppressor outlet (top) and the Cartridge inlet (edge). This is the tubing leading to waste if you just performed the filling procedure. 2. Connect a short tubing (B) between the Cartridge outlet (centre) and the Pump inlet (bottom). This is the tubing placed in the ULB -P Regeneration Solution flask if you just performed the filling procedure. 3. Connect a long tubing (C) between the Pump outlet (top) and the SAMS inlet (bottom). This is the tubing connected to the Cartridge outlet (centre) if you just performed the filling procedure. 4. Make sure the exit of the Safety Check Valve is connected to the Expansion Flask with a short tubing (D). 5. Disconnect the Cartridge vent plug and install the supplied fitting. Connect a short tubing (E) between the Cartridge Vent and the Expansion Flask. 6. Start the Pump and adjust the flow rate to a value of 80. This gives an expected flow rate of about 20 ml/min and a backpressure in the regeneration channel below 1 bar (14 psi). 7. Flush your ion chromatography eluent pump system thoroughly with purified water if it has not recently been used for suppressed anion chromatography. Use fresh eluents and wash solutions free from organic solvents. Figure 9: Connections on the SAMS Suppressor. 8. Connect the SAMS eluent inlet (top) to your column and the eluent outlet (bottom) to your detector. Note that it is recommended to install a Pressure Relief Valve (100 psi, sold separately) between your column and the SAMS to protect it against high detector back-pressures. 9. Start your eluent pump and let the system equilibrate for at least 30 minutes. Monitor the baseline of your chromatography system to determine when the suppression is stable. Failure to install the Expansion Tubing and the Safety Check Valve constitutes a risk for leakage, damage to equipment and health hazard for laboratory staff.

Instructions for Use - SeQuant CARS 7 Operation The level and stability of the background conductivity will improve during the first operating hours of a new cartridge. This baseline is monitored through your conductivity detector and ion chromatography system. Optimum Performance To get the most stable background, the CARS System should be operated also when the eluent flow has been stopped, such as during nights. When eluent is not pumped through the suppressor, protons in the Cartridge and ULB -P are not consumed. The cartridge lifetime will therefore not be negatively affected by continuous recirculation. The most optimal performance is obtained when the Cartridge is placed within the ion chromatography system compartment (column oven or similar), avoiding exposure to direct sunlight and other major temperature variations. The Cartridge should always be kept in an upright position during operation. Cartridge Expansion Tubing Air Bubbles SAMS Suppressor The SAMS is a membrane device, which is not entirely impermeable to water. Due to osmotic transfer of water between the ULB -P and the eluent taking place over the long lifespan of the Cartridge, the volume of the ULB -P may decrease, or more typically, increase. This means that some solution may leave the Cartridge through the waste tubing, but this has no effect on the performance of the system. Build-up of pressure in the CARS system will affects the performance and constitutes a risk for leakage and damage to equipment and health hazard for laboratory staff. During operation of the CARS System, air bubbles may sometimes appear within the circulating ULB -P. This does not affect the performance of the CARS unless air is accumulating in the SAMS. To avoid this, the SAMS regeneration channel outlet should be positioned slightly higher than the inlet. Always disconnect the SAMS if the separation column is being washed with solutions containing high concentrations of salt. The CARS Cartridge lifetime will otherwise be reduced and the SAMS Suppressor risks being poisoned by released contaminants. For best results, the SAMS Suppressor should be installed close to the ion chromatography column. Extensive tubing between the column and suppressor or between the suppressor and detector will lead to band-broadening of the chromatographic peaks and loss of resolution. Optimum low level of background conductivity, noise and reproducibility are achieved when the SAMS is placed in a column oven or similar compartment with controlled temperature. If your SAMS previously has been used with sulfuric acid or other low molecular-weight acids for regeneration, it must be flushed with minimum 50 ml of ultra-pure water to avoid contaminating the ULB -P. A contaminated ULB -P solution will result in a higher background level and more noise. For further instruction regarding handling SAMS, please consult its separate Instructions for Use.

Instructions for Use - SeQuant CARS Temporary Storage Store diluted ULB -P and filled CARS Cartridges plugged in a refrigerator at 5-10 C. Keep the CARS System in continuous operation during analysis even if the eluent flow is temporary stopped. However, if the ion chromatography system will not be used for a couple of days, it is recommended that the regeneration flow is stopped. If the ion chromatography system will not be used for several weeks it is recommended that the Cartridge is removed and plugged and that the Pump flow path is flushed with deionized water for about 10 minutes. The Pump should finally be drained by pumping air for one minute. Prolonged operation without liquid in the Pump may lead to increased wear of the internal parts and is not recommended. Failure to flush the Pump when disconnected might result in precipitation of ULB -P and clogging of the system. Prolonged storage of filled and plugged Cartridges, and diluted ULB -P should be performed at cold temperatures (ca 5-10 C), but not below freezing. Expected Cartridge Lifetime Eluent cations will break through the Cartridge before it is completely exhausted and a slight increase in background conductivity and noise indicates that a new Cartridge soon need to be installed. The practically useful capacity of the CARS Cartridge Small (0.5 L) is about 0.8 eq. Table 1 shows the expected practical Cartridge lifetime when used with some typical anion chromatography eluents. Table 1: Expected practical lifetime of the CARS Cartridge Small (0.5 L) when used with some typical eluents for anion chromatography. Lifetimes at other eluent concentrations or flow rates may be extrapolated from the tabulated estimates. Eluent Type and Concentration Flow Rate Estimated useful lifetime NaOH mm Na 2 CO 3 mm NaHCO 3 Full eight-hour working days mm ml min -1 ea 5.0 - - 1.0 330 10.0 - - 1.0 165 Disposal of CARS Cartridges - 1.8 1.7 1.0 320-1.8 1.7 2.0 160 The Cartridge housing is made from polyvinyl chloride (PVC) and the interior filling is a sulfonated polystyrene cation exchange resin. Unless you are required to recycle different types of plastics separately, we recommend that the Cartridge is thoroughly washed with water and recycled as an all-plastic waste. Disposal of ULB -P Regeneration Solution The chemical composition of the ULB -P Regeneration Solution is quite similar to dishwashing detergents. This means that the solution can be safely disposed in the drain if flushed with plenty of water.

Instructions for Use - SeQuant CARS 9 Disposal of SAMS Suppressors The SAMS housing is made from polyvinylidene-fluoride (PVDF) and polyether-ether-ketone (PEEK). After being thoroughly flushed with water, SAMS can be recycled an all-plastic waste unless you are required to recycle different types of plastics separately. Pump Maintenance The Pump is very robust and can operate many months without significant maintenance. Parts that might need to be replaced are the inlet and outlet check valves and the mechanical membrane in the pump head. Both these operations are rather straightforward and can be performed in the laboratory. Please contact your local SeQuant distributor for more information. Reordering Information Please contact your local SeQuant distributor for placing your order. Ord. No. Description 1.50609.0001 SeQuant SAMS Standard Suppressor 1.50610.0001 SeQuant SAMS Gradient Suppressor 1.50611.0001 SeQuant CARS Continuous Auto Regeneration System 1.50613.0001 SeQuant CARS Cartridge Small (0.5 L, capacity 0.9 eq) 1.50614.0001 SeQuant CARS Cartridge Large (0.75 L, capacity 1.3 eq) 1.50616.0100 SeQuant ULB -P Regeneration Solution (100 ml to be diluted 1+4) 1.50618.0001 SeQuant Pressure Relief Valve (100 psi) 1.50619.0001 SeQuant SAMS Installation Kit (5 m tubing and 6 ea fittings) Contact dealer Certipur single or multi element NIST traceable IC standards A Practical Guide to Ion Chromatography To learn more about ion chromatography technology and how you can optimize your separation selectivity and detection sensitivity or troubleshoot your ion chromatography application, SeQuant offers the free tutorial booklet A Practical Guide to Ion Chromatography. To ask for your free copy, please contact your local distributor or visit the website www.sequant.com. Copyright, Merck SeQuant AB, 1997-2012. All rights reserved. Document: 7820-001-203 Version 2.03 Last update: 2012-05-03 Released by TJN

Made in Germany Merck KGaA, 64271 Darmstadt, Germany Tel. +49 (0)6151-72-2440 EMD Millipore, 290 Concord Road, Billerica MA 01821, USA, Tel. +1-978-715-1335 chromatography@merckgroup.com www.sequant.com/cars We provide information and advice to our customers on application technologies and regulatory matters the best of our knowledge and ability, but without obligations or liability. Existing laws and regulations are to be observed in all cases by our customers. This also applies to any rights of third parties. Our information and advice do not relieve our customers of their own responsibility for checking the suitability of our products for the envisaged purpose.