Flexible Sprinkler Connector Braided & Unbraided

Similar documents
I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

Data Sheet 3.11 Issue F

Data Sheet 3.03 Issue D

Data Sheet 3.01 Issue C

I-VICFLEX.AB1/AB2/AB10

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

KOFULSO /Easyflex flexibles sprinklers drop distributed by

PROFLEX FLEXIBLE SPRINKLER HOSES (PAGE 1/5)

COACHSTEP TRIPLE STEP RECALL REPAIR INSTRUCTIONS RECALL# 15E-078 LABOR FLAT RATE: 0.5 HOURS

Inverted Dual High-Pressure Fluid Filter Assemblies

INSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

Paint/Solvent/Dump Valve and Flow-Through Valve

Inverted High Pressure Fluid Filters

SECTION 8 Fire Protection

Flexible Sprinkler Connections

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

Easy Riser swing check valve Models E-1 & F-1

SUPPLY JOINTS CONTENTS

Resilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator

Resilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator

FAX

PowrTwin 6900GHD Insert Sheet

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE INCLUDE MANUAL: S-632 GENERAL INFORMATION MANUAL (PN )

Nylon Fluid Regulators

Welded Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems

4. Remove (4) 10mm and (1) 7mm bolt that holds fascia at front corners, on each side

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Escape Cylinder and Valve

I-799/79V Coil Components

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

PRODUCT SAFETY NOTICE

Miniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.

Model RM-1 Riser Manifold Commercial and Residential General Description

XP-300 Series Sprinklers Installation & Service Instructions

Tubing. Barb. Sleeve. Attaching the sleeve achieves a larage retaining force. Detaching it allows easy removal of the tube. Electroless nickel plated

Section 3. Stainless Steel Series. Shurjoint Stainless Steel Piping Series Grooved Mechanical Couplings. Cast Grooved Fittings.

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

INSTALLATION INSTRUCTIONS

Valves & Flow Control Components Valves & Flow Control Components

Introduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.

PRODUCT SAFETY NOTICE DEALER/INSTALLER NOTICE

Miniature Fittings Series M

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES

INSTALLATION INSTRUCTIONS Air Spring Kit Dodge WD IMPORTANT NOTES

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Blow Off Valve Retrofit Kit

INSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES

Fluidizing Pickup Tube Kits

Tube Applicable for nylon, soft nylon and polyurethane tubing.

TECHNICAL DATA OBSOLETE

INSTALLATION INSTRUCTIONS

argco.com

Signet 2517 Brass Paddlewheel Flow Sensor * *

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

ER TRANSIT PARTS MANUAL. Cooling Section. Page 7-1. Cooling 05/97

27" Natural Gas Conversion Manual

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

TECHNICAL DATA CAUTION

2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS

Fire Protection Price List

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

1 1/4 NPT FILTER 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS. Hole Size Designation 150 Mesh 1M150

3/4" BRASS AGRICULTURAL SPRINKLERS WR-33 WR-32 WR-35

PRESS SWING CHECK VALVES. UPC NSF1-8 Double O-Ring Blow Out Proof Stem 250 CWP Max Temp: 300 F

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

Inde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No

Viking Installation Guide

NETAFIM FLEXIBLE PIPES FLEXNET HP INNOVATIVE MAINLINE AND SUB-MAINLINE PIPING SOLUTIONS THAT ARE EASY TO INSTALL, RECOIL AND RELOCATE

PRODUCT MANUAL GEARCAGE SYSTEM - ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS: Description

USER MANUAL. LP Unit 5000 PSI. HP Unit 7500 ALL - IN - ONE ALL - IN - ONE ALL - IN - ONE. 4" Drive Handles. LP Units Available in 12" Insertion Length

READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.

Miniature Fittings Stainless Steel 316. Hose nipple. Barb. Configuration for easy insertion into the tube Holds the tube tightly.

Fire Protection Price List. Piping. Systems. Solutions A FP.

TOYOTA TRUCKS / SUVs COLD AIR INTAKE Section I Installation Preparation. 4.0L V6 (1GR-FE) Part Number(s): PTR

Installation Instructions

Suspension Leveling Kits HIGH LOW REGULAR. .f. KT ASSEMBLY AND USAGE GUIDE

SINGLE WALL AL 29-4C SPECIAL GAS VENT

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

RA-20 Paint/Solvent/Dump Valve

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

Schedule 40 Fittings & Accessories Turf Swivel Joints

High-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability

INSTALLATION INSTRUCTIONS

1 1/4 NPT FILTER SIZE DESIGNATION PRICE 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS HOLE SIZE DESIGNATION PRICE

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Section 8. Copper Series

Fast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO

MULTI-JET WATER METERS

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

General Information. Assembly Instructions B L R F. 3000TM Fold Assist Kit

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

CENTRO-MATIC PUMP, MODELS 84050, & 85460

Quicklub Lubrication Systems Fittings, Adapters and Accessories

ONE TOUCH FITTINGS Series WP2

MODEL VFF30 REPAIR KIT INSTALLATION INSTRUCTIONS

Transcription:

Model: FX / FXU Technical Features Hose Types: raided or Unbraided Hose Lengths:, 6, 8, 60, 7 Maximum Working Pressure: 75 PSI Maximum Working Temp: 5 F K factor: ½ Outlet 5.6, ¾ Outlet 8.0 onnections: To branch line (inlet) via /5.mm NPT male thread onnections: To sprinkler (outlet) via ½ or ¾ 5mm or 0mm NPT female thread pprovals & Standards raided: UL, UL, FM 67 Unbraided: UL, UL Part Material Flexible Hose Nut Type 0 Stainless Steel S0 Gasket Seal Nylon 66 Silicon Zinc Plated Grade 00 Steel End & enter rackets L Square ar Zinc Plated Steel Grade 00 Steel K J E. Stainless Steel Flexible Hose. onnection Nut G. Sprinkler H. Steel ar F G H I. Inlet Nipple D. E. enter racket I. J. K. F. L. ranch Line Inches Outlet Size Inches ends Min end Sch. 0 Pipe Inches Outlet Size Inches ends Min end Sch. 0 Pipe 6 8 60 7 / / / / / / / / / / 6.. 8. 6.8 6. 5.8 76. 70. 6 8 60 7 / / / / / / / / / / 0 8 55 6 8 86

Model: FX / FXU Inlet Nipple NPT FX RIDED UL / FM REDUER 5.5 Length* Inlet Nipple NPT FXU UNRIDED UL REDUER 5.5 Length* * Other Reducer lengths vailible Suspended eiling T-ar Grid System STNDRDS OF OMPLINE UL standards for Flexible Sprinkler Hose with Fittings for fire protection service. 5 6 6 5 Item Stainless Steel Flexible Sprinkler Hose Steel Square ar 5 & 50 97mm End racket with Wing Nut enter racket D-Type / or / Reducer NPT 97mm End racket with Wing Nut FM class number 67 approved standard for Flexible Sprinkler Hose with Threaded Ends and Fittings. NFP Standard for the installation of sprinkler system. NFP D Standard for the installation of sprinkler systems in one and two family dwellings and manufactured homes. NFP R Standard for the installation of sprinkler systems in residential occupancies up to and including four stories in height. STM 65 Standards specification for the manufacture, performance, and testing of metal suspension systems for acoustical tile and lay-in panel ceilings. STM 66 Standards practice for installation of metal ceilings suspension systems for acoustical tile and lay-in panels.

Model: FX / FXU Metal Joist / Stud (Option ). Metal Stud End racket (Part# FX-E-MTL). Metal Stud ( hannel) Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket Metal Joist / Stud (Option ). End racket (Part# FX-E-97MM). Metal Stud ( hannel). -/ #0 Self-Drilling Sheet Metal Screw Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket Wood Joist / Stud. End racket (Part# FX-E-97MM). Wood Joist. -/ #0 Self-Drilling Wood Screw Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket

Model: FX Parts List FX-NPT-050 FX-NPT-075 FX-NPT-700 FX-NPT-900 Straight Reducer /" Outlet x 5-/ Length Straight Reducer /" Outlet x 5-/ Length Straight Reducer /" Outlet x 7 Length Straight Reducer /" Outlet x 9 Length FX-NPT-INL FX-S-5 Square ar - 5" FX-S-50 Inlet Nipple x -/8 NPT Square ar - 50" FX-90D-50 FX-90D-75 90º Degree Elbow Reducer /" NPT 90º Degree Elbow Reducer /" NPT FX-GSKT EPDM Gasket FX- enter racket DX--D enter racket D TYPE FX-E-97MM 97mm End racket FX-E-MTL STUD Metal Stud End rackets

Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. WRNING * Read and follow these installation instructions before attempting to install Fivalco products. * Installer must understand the purpose of these products with common standards of the industry for safety, and the consequences of improper product installation. * Wear safety glasses, hardhat, and foot protection during installation. * Failure to follow these instructions could cuase improper sprinkler operation, resulting in serious personal injury and / or property damage. * The flexible hose are not to be bent within.5 inches of the connection nut at both ends. SSEMLY INSTRUTIONS () Pipe side: pply PTFE thread seal tape or pipe joint compound to the tapered threads of the inlet nipple. () Flexible hose side: DO NOT use both pipe PTFE or pipe joint compund. Tighten the inlet nipple into branch line using pipe wrench. onnect the nut of flexible hose to the inlet nipple using a pipe wrench. DO NOT use PTFE or pipe joint compound on the inlet nipple at the hose side since there is already a seal gasket in place to seal the joint. Tighten the connection to a maximum torque of 5 ft-lbs/0 N*m. Too much torque may cause damage to the seal gasket.

Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. onnect the nut of the flexible hose to the outlet reducer. DO NOT use PTFE or pipe joint compound since on outlet reducer at the hose side since there is already a seal gasket in place to seal the joint. Tighten the connection to a maximum torque of 5 ft-lbs/0 N*m. TOO much torque may cause damage to the seal gasket. 5 5 Indentify the t-bar bracket assembly and confirm if all parts are in present: () end bracket at each side, () center bracket, () square steel bar. djust as necessary if the positions of the end brackets to match the length of the t-bar rails. 6 6 ttach the end brackets to the t-bar rails by loosening the wing nut and pushing in the end bracket into the t-bar rail. 7 7 Tighten the wing nut to a torque of ft-lbs/ N*m to secure end brackets to the rails.

Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. 8 8 djust the positions of the center bracket and the flexible hose to desired location. 9 9 Slide the outlet reducer into the center bracket. 0 0 With outlet reducer positioned inside the center bracket, grasp and firmly close the handle completely to secure the reducer in place. Optional: Tighten the wing nut to a torque of ft-lbs/ N*m.

Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. pply PTFE or pipe joint compound to the male threads of sprinkler. Install the sprinkler into the female threads of the outlet reducer by following sprinkler manufacturer s installation instructions. HRD-LID EILING JOIST / STUD SSEMLY INSTRUTIONS Metal Joist / Stud (Option ) Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Slide the Metal Stud End racket ( FX-E-MTL) on each end of square steel bar, making sure the lip of the bracket engages the metal joist/stud. Tighten the wing nuts to a torque of ft-lbs/ N*m to secure to the metal joist/stud. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems. Metal Joist / Stud (Option ) Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Place the bracket assembly on top of the metal joist/stud, where the end brackets ( FX-E-97MM) are on the inner side of each metal joist/stud. Drill -/ inch long #0 self-drilling sheet metal screws () in the locations shown in the picture. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems. Wood Joist / Stud Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Place the bracket assembly on top of the wood joist/stud, where the end brackets ( FX-E-97MM) are on the inner side of each wood joist/stud. Drill -/ inch long #0 self-drilling wood screws () in the locations shown in the picture. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems.