AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

Similar documents
Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

SERVO-TOP II ELECTRONIC ACTUATOR

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

1/16 DIN Temperature Controller E5CS

Signet Pressure Transmitter

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

M9216 Series Electric Spring Return Actuators

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

707Ex. Users Manual. ma Calibrator

MODEL CUB7 MINIATURE ELECTRONIC 8 DIGIT COUNTER/TIMER

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

USERS MANUAL MCD REMOTE OPERATOR

Signet Pressure Transmitter

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

TOWA SEIDEN INDUSTRIAL CO., LTD.

EPS/ELA-Series User Manual EPS/ELA 250W

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

General Specifications

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

DIGITAL RCD(ELCB) TESTER

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Model Number Structure

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

VA-4233-GGx Series Electric Valve Actuators

General Electrical Information

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

DIAMOND POINT VIBRATING PROBES

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Current Switches and Transducers

CVR-625. Compact Vibrating Rod Instruction Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

1.Safe testing IMPORTANT:

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Module Type Controller SRX Temperature Control Module [Basic Type] X-TIO-A Instruction Manual

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

Signet Temperature Transmitter

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Intelligent torque meter tester

i3000s/i2000 Flex AC Current Probe

362 Clamp Meter. Users Manual

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

DC POWER SUPPLY ALIMENTATION C.C.

HS1E Series Full Size Interlock Switch with Locking Solenoid

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

MODEL IRMA - INTELLIGENT RTD MODULE WITH ANALOG OUTPUT

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Model 550 Series Vibration Switches

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

SG-B1 SERIES / SG-A1 SERIES

HS6B Series Subminiature Interlock Switch

GT5P Series ON Delay Timers

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

PTC8001 Temperature Calibrator

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

User s Manual Power Supply IM E. 5th Edition

Emotron DCM Control Unit

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Differential Pressure Transmitter

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Switching DC Power Supply

MODEL 3567A. Digital MΩ Tester. Instruction Manual

HS1E Series Full Size Solenoid Locking Switches

Safety design conforming to the following provisions

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

i400s Calibration Information Introduction

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Direct Coupled Damper Actuator Model MY6050A1001

GTS 15/25/40/50/60/75/90/120A

INSTALLATION/OPERATING INSTRUCTIONS TSC

P445 Series Electronic Lube Oil Control

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Door Interlock Switches

GE Sensing & Inspection Technologies

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Transcription:

INSTRUCTI MANUAL DC ALARM (dual or quad alarm trip; field-configurable) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. This equipment is for use in general industrial environments, therefore may not be suitable for applications which require higher level of safety (e.g. safety or accident prevention systems) or of reliability (e.g. vehicle control or combustion control systems). For safety, installation and maintenance of this equipment must be conducted by qualified personnel. PACKAGE INCLUDES: Signal conditioner (body + base socket + input resistor)... () Input resistor is provided only with current input type. MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTI MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. SYMBOLS USED THE PRODUCT AND IN THIS MANUAL The symbol indicated on the equipment, means that the user must refer to the related parts in the manual for safe operation of the equipment. It is essential to read the instructions wherever the symbol appears in the manual. WARNING: is reserved for conditions and actions that can cause serious or fatal injury. CAUTI : is reserved for conditions and actions that can cause injury or instrument damage. WARNING INSULATI CLASS Basic insulation (Signal input or output to Power input: V) is maintained. If insulation failure may result in equipment, hazardous voltage (maximum 4 V) may result to signal input and then electric shock may cause. Prior to installation, prepare supplemental insulation (equivalent basic insulation) between signal input and external circuits. CAUTI REGARDING SAFETY If equipment is not used in a manner not specified by M- System, the protection provided by the equipment may be impaired. CFORMITY WITH LOW VOLTAGE DIRECTIVE OR UL This equipment is suitable for use in a Pollution Degree environment and in Installation Category II (transient voltage V). Altitude up to meters. The equipment must be mounted inside a panel. The equipment must be installed such that appropriate clearance and creepage distances are maintained to conform to EU/UL requirements. Failure to observe these requirements may invalidate the EU/UL conformance. CFORMITY WITH EMC DIRECTIVE Insert a noise filter for the power source connected to the unit. TDK-Lambda Noise Filter Model RSNA- or equivalent is recommended. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. SIGNAL INPUT This terminal is used for signal input. Do not connect or measure to the circuits including transient voltage V. Refer to INPUT SPECIFICATIS in detail. OUTPUT TERMINAL Never use the output terminal under any load that exceeds the rated values. Otherwise it will impair prescribed performance and cause burning of the equipment itself. WIRING For wiring connection, refer to TERMINAL CNEC- TIS and wire correctly. Fire, electric shock and failure cause if wire are incorrectly connected. Wire using vinyl insulated power cable that meet input voltage and load current for equipment and screw by an adequate torque. Loose screws may abnormally generate heat and fire may cause. (Proper tightening torque [N m] :..) Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. --, Minamitsumori, Nishinari-ku, Osaka - JAPAN Phone: +()- Fax: +()- E-mail: info@m-system.co.jp EM- Rev. P. /

POINTS OF CAUTI POWER INPUT RATING & OPERATIAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: AC Power M: 4 V AC, Hz, maximum VA ( 4 V AC, 4 Hz) DC Power R: 4 V DC (4 V ±%), maximum. W P: V DC ( V), maximum. W GENERAL PRECAUTIS Before you remove the unit from its base socket or mount it, turn off the power supply and input signal for safety. ENVIRMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within - to + C ( to F) with relative humidity within to % RH in order to ensure adequate life span and operation. AND... The unit is designed to function as soon as power is supplied, however, a warm up for minutes is required for satisfying complete performance described in the data sheet. Never use the internal relay under any load that exceeds the rated contact values including the switching capacities (contact voltage and contact current). Otherwise it will impair prescribed performance (insulation failure, contact welding, contact failure) and cause burning of the Relay itself. PENT IDENTIFICATI Connection Diagram Specifications Base Socket INPUT SPECIFICATIS DC Current: ma DC; shunt resistor attached to input terminals (. W) Operational range: ma DC (with Ω /. W) Minimum increment:. ma Default setting: 4 ma DC DC Voltage: - + V DC for S; - + V DC for S Operational range: -. +. V DC for S; -. +. V DC for S Minimum increment: mv for S; mv for S Default setting: - + V DC for S; - + V DC for S OUTPUT SPECIFICATIS Quad Alarm Relay rating: V AC @ A (cos ø = ) 4 V AC @. A (cos ø = ) V DC @ A (resistive load) Dual Alarm Relay rating: V AC @ A (cos ø = ) 4 V AC @. A (cos ø = ) V DC @ A (resistive load) Small load current type Relay rating: V DC @ A (resistive load) INSTALLATI Detach the yellow clamps located at the top and bottom of the unit to separate the body from the base socket. DIN RAIL MOUNTING Set the base socket so that its DIN rail adaptor is at the bottom. Position the upper hook at the rear side of base socket on the DIN rail and push in the lower. When removing the socket, push down the DIN rail adaptor utilizing a minus screwdriver and pull. Clamp (top & bottom) DIN Rail mm wide Body Input Resistor Spring Loaded DIN Rail Adaptor Shape and size of the base socket are slightly different with various socket types. WALL MOUNTING Install using M4 screw with referring to the right dimension. Install by screw that is securely fastened or equivalent means. -M4 4.(.) 4±. MOUNTING HOLES (TOP VIEW) --, Minamitsumori, Nishinari-ku, Osaka - JAPAN Phone: +()- Fax: +()- E-mail: info@m-system.co.jp EM- Rev. P. /

FRT VIEW & PROGRAMMING PROGRAMMING PROCEDURE ) Press UP or DOWN key until display indicates. ) Press DATA UP or DOWN key and choose or on DATA display. : Only alarm setpoints are modifiable. : All parameters are modifiable. ) Press UP or DOWN key until display shows the No. you need to change. 4 ) Press DATA UP or DOWN key and choose a DATA No. or value you need on DATA display. ) Repeat above and 4. (Entered data is stored when you move to a new.) ) Press UP or DOWN key until display indicates. ) Press DATA UP or DOWN key and choose on the display. ) Press UP or DOWN key until display indicates P. DATA display shows process input. (You can now check data setting by choosing No.) Note: DO NOT press UP and DOWN keys simultaneously. *Monitor LEDs DATA ALARM L4 L L L DATA DATA Display No. Display DATA UP-DOWN Keys No. UP-DOWN Keys *L or L4 does not turn on for dual output type. MDF. CODE DATA CTENTS DEFAULT SETTING P N/A - Process input display in engineering unit (as set in, ) ---- L L L L4,,,, - * - * - * - * L alarm setpoint in engineering unit L alarm setpoint in engineering unit L alarm setpoint in engineering unit * L4 alarm setpoint in engineering unit *, Modification code : Data indication only. : Only L L4 are modifiable. : All parameters are modifiable. N/A Status indication ( is normally indicated.) : Normal : Memory error : Out of input range - +% N/A, 4 Input range : S, : S, 4: Z 4 N/A -.. Input indicated in % (as set in, ) ---- -.... - -,, Decimal point position (Specify the number of digits) Zero adjustment (%) (fine adj. of the value set in ). Quad:. Quad:. Quad:. Quad:. Gain adjustment (fine adj. of the value set in ). Display range scaling % * Display range scaling % *.. : : _. _ :. : _. _ Power -delay time (seconds) Alarm -delay time (seconds),,, 4 Moving average (sampling cycle: msec.) : No, : 4 samples, : samples, : samples, 4: samples 4 L trip operation L trip operation L trip operation L4 trip operation (: Lo, : Hi) (: Lo, : Hi) (: Lo, : Hi) * (: Lo, : Hi) * Power-saving mode : Continuous display* 4 : Time before display turned off (minutes) L coil at alarm (: Energized, : De-energized) L coil at alarm (: Energized, : De-energized) L coil at alarm (: Energized, : De-energized)* L4 coil at alarm (: Energized, : De-energized)* N/A ---- Version No. indication ---- Dual:. Dual:. Specified when ordering Quad: Quad: Quad: Quad: Dual: Dual: --, Minamitsumori, Nishinari-ku, Osaka - JAPAN Phone: +()- Fax: +()- E-mail: info@m-system.co.jp EM- Rev. P. /

MDF. CODE DATA CTENTS DEFAULT SETTING 4 L hysteresis (deadband) in engineering unit L hysteresis (deadband) in engineering unit L hysteresis (deadband) in engineering unit * L4 hysteresis (deadband) in engineering unit *.... S: -.. S: -.. Z:.. S: -.. S: -.. Z:.. % input voltage/current ( < ) S: -. V, S: -. V, Z: 4. ma % input voltage/current ( < ) S:. V, S:. V, Z:. ma Latching control (: Disabled, : Enabled) Selecting resets latching relays. Turning power supply off also resets them. ---- Alarm indication (:, : ) The MSD indicates the L, while the LSD indicates the L4. ---- *. Selectable within the display scaling range *. Quad alarm trip type only *. Of the range set in,. <. *4. when power is on. After power is turned on, pressing any key enables to turn on continuously. CNECTIS EXTERNAL DIMENSIS unit: mm (inch) TERMINAL ASSIGNMENTS CLAMP (top & bottom) INPUT RESISTOR (model: REM). (.) (.) (.) (.) (4.) (.).4 (.) DIN RAIL mm wide [. (.)] 4. (.) dia. MTG HOLE (.) deep M. SCREW 4 (.) (.) 4 (.) 4 (.4) Input shunt resistor attached for current input. When mounting, no extra space is needed between units. For wiring connection, refer to TERMINAL CNECTIS and wire correctly. Fire, electric shock and failure cause if wire are incorrectly connected. TERMINAL CNECTIS Connect the unit as in the diagram below or refer to the connection diagram on top of the unit. n N.O. RELAY n N.C. RELAY n SPDT RELAY INPUT + R * L4 OUTPUT L OUTPUT L4 OUTPUT L OUTPUT INPUT + R * N.C. N.O. L OUTPUT L OUTPUT L OUTPUT N.C. L OUTPUT L OUTPUT N.O. L OUTPUT U(+) V( ) POWER U(+) V( ) POWER * Input shunt resistor attached for current input. * Input shunt resistor attached for current input. --, Minamitsumori, Nishinari-ku, Osaka - JAPAN Phone: +()- Fax: +()- E-mail: info@m-system.co.jp EM- Rev. P. 4 /

CHECKING ) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. ) Power input voltage: Check voltage across the terminal with a multimeter. ) Input: Check that the input signal is within % of the full-scale. 4 ) Alarm operations: Check the alarm operations referring to the figure below. ) Output load: Check that the output rating road is: Output code and : 4 V AC / VA or V DC / W Output code : 4 V AC / VA or V DC / W Output code A, A and A: V DC / W For maximum relay life with inductive load, external protection is recommended. Alarm Trip Operation Terminal No. in parentheses Example with quad N.O. contacts (LL, L, H, HH) MAINTENANCE Regular calibration procedure is explained below: CALIBRATI Warm up the unit for at least minutes. H (HH) Setpoint Increase the input signal from a value lower than the setpoint and check that the relay trips at the H (or HH) setpoint within the setpoint accuracy described in the data sheet. L (LL) Setpoint Decrease the input signal from a value higher than the setpoint and check that the relay trips at the L (or LL) setpoint within the setpoint accuracy described in the data sheet. When the setpoints are shifted, please contact M-System s Sales Office or representatives. L ( ) L ( ) L ( ) L4 ( ) Input (%) LL L H HH LIGHTNING SURGE PROTECTI In order to protect the unit from lightning surges entering through power supply cables, use of appropriate lightning surge protectors are recommended. Please contact M-System. Trip Operation in Power Failure Output code, A: All relays turn off. Output code, A: All relays turn on. Output code, A: Terminals, turn on. --, Minamitsumori, Nishinari-ku, Osaka - JAPAN Phone: +()- Fax: +()- E-mail: info@m-system.co.jp EM- Rev. P. /