PATHWAY LIGHTING 3100 SERIES LOUVERED BOLLARD

Similar documents
PRECISION ARCHITECTURAL LIGHTING 8000 SERIES

part number description number per fixture

TORNADOTM BOLLARD PATENTS PENDING

GATEWAY ARCHITECTURAL LIGHTING APPEARANCE PERFORMANCE ENDURANCE

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

KAD250MR3TBSPD04 Wall Fixture

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

V-Bollard Architectural LED Luminaire / Bollard

V-Bollard Architectural LED Luminaire / Bollard

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

3900 BOLLARD SERIES.

C A M B E RTM PATENTS PENDING

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC


Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Seem 6. Narrow 6 aperture slot fluorescent luminaire that integrates with the ceiling for a clean unobtrusive aesthetic.

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

Perimaliter Wallpacks

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Light Nodes. Low Profile Surface Mounted Luminaires for LED Lamps. Patents Pending

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options

Options. Pole and Arm. Suitable for wet locations

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

SITE /ROADWAY BNS SERIES. Bounce. Pedestrian Scale Luminaire W H.I.D.

A R E A & S I T E WA L L M O U N T E D B O L L A R D S T E C H N I C A L S P E C I F I C AT I O N S

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

PGA Parking Garage Luminaire

Applications. Standard Materials

Series Mounting Accessory Distribution Source Color Temperature Voltage 10DEG 20DEG 40DEG 60DEG 60X20DEG

APPENDIX B: LISTS OF APPROVED MATERIALS

Perimaliter Wallpacks

DE Down Light. Quick Facts. LED Down Lights. Straight Shroud

BOW SX - LED Luminaire

seem 4 grid features dimensional data performance

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

LED Parking Garage. Optional motion sensor

Seem mm 4.50" 4.00" 101.6mm. Narrow 4" linear fluorescent allows for both individual or continuous runs.

PGL350P W PS Wallpack

Laredo Decorative Wallpack Family

Applications. Standard Materials. Certifications and Compliances

Quick Facts LED RECESSED LUMINAIRES

IMPACT FLOODLIGHT Architectural Flood Luminaire

CC/CCS21 21" Post Top Mounted, Curvilinear, LED revision 5/9/11 kim_cc21pled_spec.pdf

DELTA RAIL SYSTEM SYMMETRIC OPTICAL SYSTEM STANDARD SPECIFICATIONS DR 1 320MH-PS. 29,700 36,000 40, , mm 400MH 400MH-PS 1000MH-BT37 DR 2

Evolve LED Wall Pack. N Series (EWNB)

Laredo - Decorative Wallpack Family

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

Ritorno Square Asymmetrical LED

BOCA. Ingrade Low Voltage Lighting Products

TWH LED TWP LED TWH TWP LED LED

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

80 Watt Multi-Purpose LED Area Light

Outdoor LED Products. A complete selection of outdoor LED luminaires

Horizon Patient Bed Light LED and Fluorescent Solutions

AFL FLOODLIGHT SERIES

LUMINAIRE SCHEDULE _CUSiteLightingSchedule_092815_GJ.xls 9/28/2015 WATTS / LUMINAIRE ALTERNATE MANUFACTURERS

PG Series. Our PG Series has now been expanded to complete your entire site needs. With added housing shapes of round and square we offer

VINCI-LED Wall/Area/Flood Lighting

ORDERING INFORMATION: 120 Volts (120)

seem 4 suspended led features dimensional data mounting information performance Narrow extruded aluminum 4 linear direct LED.

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Lighting: Explosionproof Area HID. Applications. Standard Materials

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

Verve IV. Suspended linear direct/indirect fluorescent with radial or flat baffle or parabolic louver.

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

1400 Architura RGB Outdoor Linear LED

BSS610 GENERAL INFORMATION - FIXTURE HOUSING

Quick Facts LED AREA LUMINAIRE

BDT Product Sales & Support (951) (800)

SLIM AREA LIGHT. 50,000 Rated Life Hours. Product Description. 360W Type 3 Lens. 100W Type 5 Lens. Color Choices. Features & Benefits

304 Series LED Recessed Canopy Luminaire

TYPE APPROVALS. Diffused lens option Programmable occupancy sensor (dimming) SiteSync wireless controls 130+ lumens per watt

BetaLED Recessed Canopy Luminaires

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Contents A A L. 3 Scales 4 Spectra Indirect 6. Interior 8. Exterior 9. Arm Options-pole 10. Arm Options Wall 11. Construction 12.

T9 Exterior Range. p64. n CALDERA. p65. n BOCA JUNIOR. p66. n BOCA. p67. n ESEDRA. p68. n LITEPK. p69. n FL1. p70. n BOL. p71.

OSQ Series LED Area/Flood Luminaire Medium

Autobahn Series ATB0 Roadway Lighting

Avenue A. Grid Mount (Open Shown) Drywall Flange (Open Shown) louver lens mr16

Campana DETAILS CN55P1A. IP67 EPA: 1.8 FT 2 Weight: 52 lbs - 24 kg CN55P1B

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

Capella 3. Project Name. Construction. Optical System. Product Applications

304 Series LED Recessed Canopy Luminaires

OSQ Series OSQ LED Area/Flood Luminaire Large

1SA / ALT3P35/ 120L5K277/ WH/ A26

Series Mounting Accessory Distribution Source Color Temperature Voltage 10DEG 20DEG 40DEG 60DEG 60X15DEG

Landscape LED 12V/120V/277V. LED Collection. Outdoor Landscape Luminaires. All-Inclusive LED Collection

19.0" (482mm) Performance Summary 3.1" (79mm) NanoOptic Precision Delivery Grid optic Receptacle location (ordered as an option)

Overall Dimensions. Specifications

Architectural-quality solar lighting products

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

The PREMIER TM. II Series

The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

Bavaria Downs. Chaska, MN. Lighting

Transcription:

PATHWAY LIGHTING 3100 SERIES LOUVERED BOLLARD

The Hydrel 3100 Series Low Level Area Lighting The 3100 Series Bollard provides simplifi ed geometric fms that will both compliment and blend with a variety of architectural settings. Rugged in design and functional in perfmance, these bollards will meet even the most demanding installation requirements. When long term durability and ease of installation is what s needed in a bollard, Hydrel can fi ll the need. Interlocking louvers, extruded aluminum pillar, and welded cast aluminum mounting plates are the key to the 3100 series success. A patented 6-point internal level/mount technology makes the external mounting screws and leveling methods of existing bollards obsolete. A perfmance based louver system utilizing a low glare upper surface combined with a high refl ectance lower surface maximizes light output while reducing offensive glare common in most bollards. 1

PERFORMANCE A remarkable blend of DESIGN + PERFORMANCE makes the 3100 Series Bollard an excellent lighting solution f pathway applications. Light patterns are wide and pleasingly unifm. Structural integrity is unmatched, and the use of superi materials and long-lasting fi nish promises decades of use with minimal maintenance. Rugged reliability is a Hydrel trademark, and the 3100 Series bollard is no exception. The architectural design and customizable aesthetic options combine with the superi optical and mechanical perfmance that Hydrel is known f without compromise. The 3100 Louver Bollard blends with similar geometric fms as a low level lighting fi xture. Superi Perfmance 2 Vandal Resistant Base Extruded aluminum pillar welded to top and bottom plates provide maximum structural integrity. Durable Louver Assembly Interlocking diecast aluminum louvers provide impact resistant assembly. Ease of Installation Removable access do creates easy access to patented 6-point internal level mount system and wire splice make-up. Convenient Ballast Access Ballast lift allows f easy component maintenance and wattage exchange. Increased Efficiency High refl ectance white fi nish on underside of louvers optimizes perfmance and increases pathway light levels. IES Cutoff and Reduced Glare Standard matte black fi nish on topside of louvers creates cutoff distribution and minimizes glare. Optional Fward Throw Distribution Fward throw refl ect redirects backlight increasing perfmance by 50%. Image shows the access do held in place by two allen head screws. Once the do is removed, the mounting bolts, levelers, and wire splice connections can be conveniently accessed. The ballast can be accessed by loosening two bolts located just underneath the lift. Once the bolts are loosened, the ballast tray will slide down into the access do opening f maintenance and/ repair of all components.

DISTRIBUTION Extensive testing assures that aggressive contact by pedestrians will not weaken noticeably damage a 3100 bollard. Directional light patterns can be independently aimed, allowing bollards to be aligned parallel perpendicular to paths and stairways. Premium m crosion on resistant materials and powder coated fi nishes shrug off environ- mental contamination. Even in crosive coastal areas, the 3100 bollard maintains it s iginal appearance over many years of use. Typical Applications FORWARD FT DISTRIBUTION SYMMETRIC SYM DISTRIBUTION S S S 12 10 STAGGERED ON 12 PATH CENTERED ON 10 PATH Lamp Lumens E min E ave Spacing (S) Lamp Lumens E min E ave Spacing (S) 100HPS 8800 1.2 fc 6.2 fc 40 ft 100HPS 8800 1.2 fc 6.0 fc 22 ft 100CMH 8800 1.0 fc 6.0 fc 40 ft 100CMH 8800 1.0 fc 5.9 fc 22 ft 100MH 7900 0.9 fc 5.2 fc 40 ft 100MH 7900 0.9 fc 5.3 fc 22 ft 70HPS 5800 1.5 fc 5.5 fc 32 ft 70HPS 5800 1.4 fc 4.8 fc 18 ft 70CMH 5800 1.4 fc 5.3 fc 32 ft 70CMH 5800 1.4 fc 4.8 fc 18 ft 70MH 4700 1.1 fc 4.3 fc 32 ft 70MH 4700 1.1 fc 3.8 fc 18 ft 50HPS 3700 1.3 fc 4.3 fc 24 ft 50HPS 3700 1.2 fc 3.4 fc 16 ft 50CMH 3800 1.2 fc 4.3 fc 24 ft 50CMH 3800 1.2 fc 3.5 fc 16 ft 50MH 3200 1.0 fc 3.6 fc 24 ft 50MH 3200 1.0 fc 2.9 fc 16 ft 42TRT 3200 1.0 fc 3.3 fc 24 ft 42TRT 3200 0.9 fc 2.7 fc 16 ft 32TRT 2400 1.1 fc 3.4 fc 20 ft 32TRT 2400 1.0 fc 2.4 fc 14 ft 26DTT 1800 1.0 fc 2.8 fc 16 ft 26DTT 1800 1.0 fc 2.0 fc 12 ft Notes: 1. F wider paths, decrease fi xture spacing. F lower light levels, decrease lamp wattage. 2. To calculate maintained illuminance, multiply values by appropriate light loss fact. 3. All HID lamps are coated. 4. Values shown are f 3100 42. Please visit www.hydrel.com f complete photometric data. 3

SPECIFICATION 3110 3120 3130 3140 9 Dia (229) 9 Dia (229) 8 (203) 8 (203) FIXTURES Available in four different designs. Two standard sizes: 36 w/ 30 light center height and 42 w/ 36 light center height. Two distributions SYM and FT. FT includes a fward throw reflect. All standard and custom finishes are available. DIMENSIONS MATERIALS Premium low copper content A360 alloy die-cast aluminum top housing and louvers. Extruded and tempered aluminum pillar with internal cast aluminum mounting plates. Bosilicate glass lamp enclosure, silicone gasketed. Stainless steel fasteners. FINISH TGIC polyester powder coated in a range of textured semi-matte finishes. Louvers are powder coated matte black on topside and high reflectance white on underside. 35.5 (902) 41.5 (1054) 34 (864) 40 (1016) Light center height 30 (762) 36 (914) 8 (203) 8 (203) 35 (889) 41 (1041) 34 (864) 40 (1016) MOUNTING To ensure structural integrity, the 3100 bollard avoids traditional set-screw mounting. Instead, a heavy duty cast aluminum mounting plate is internally welded to the base. Slotted anch bolt holes and three easily accessible leveling pads allow the luminaire to be installed in perfect alignment. Anch bolt infmation and installation instructions are available at www.hydrel.com. 1 3 4 5 HYDREL PATENTED 6-POINT BOLLARD MOUNTING TYPICAL COMPETITIVE BOLLARD MOUNTING 1 Anch bolt nut and lock washer tightening pre-loads the anch bolts and levelers resulting in a stronger bollard mounting 1 Base casting suspended between nuts and flat washers over anch bolts. No preload on anch bolts. Base plate must be leveled pri to installing fixture post/head 2 Anch bolts, independent of levelers, thru slots in weldedin base plate 2 1 2 Bollard post casting resting flush on top of base casting 3 3 Hex socket set screws thru bollard post into base casting 3 Drive on top of leveler allows leveler to be screwed up down 2 4 Concrete foundation 4 Base plate welded to post 5 Hand-hole allows access to levelers, anch bolts, and wiring, enabling entire bollard to be installed as a complete unit 6 4 6 Concrete foundation 7 Side loading of bollard base transfers to pre-loaded anch bolts, levelers, and welded base plate. Side loading increases the linear tension on the anch bolts and levelers maintaining a rigid mounting 7 8 Pre-loading of anch bolts in linear tension 8 4 9 9 Pre-loading of levelers in linear compression with concrete foundation 5 Side loading of bollard base transfers to set screws often resulting in set screw and mounting base failures 5 6 Gap between bollard post and concrete foundation allows bollard to be rocked back and fourth 7 6 7 Nut and flat washer, top and bottom, levels and suspends base casting

3100 ORDERING GUIDE EXAMPLE: 3100 100S 42 120 SYM SF LPI DBLB Model Lamp Type Height Voltage Distribution 3110 3120 3130 3140 Fluescent 26DTT G24Q-3 32TRT GX24Q-3 42TRT GX24Q-4 MH 50M 1 ED17 Med. 50CM 1 ED17 Med. 70M 1 ED17 Med. 70CM 1 ED17 Med. 100M 1 ED17 Med. 100CM 1 ED17 Med. 35CMT6 T6 G12 70CMT6 T6 G12 20CMT4 T4 G8.5 35CMT4 T4 G8.5 70CMT4 T4 G8.5 HPS 50S 1 E17 Med. 70S 1 E17 Med. 100S 1 E17 Med. LPS 18L 7 T17 BY22D 35L 7 T17 BY22D 36 42 120 208 220 240 277 347 120/277 TB MVOLT 2 Internal SYM Symetrical, 360 FT Fward Throw, 180 Options Fusing SF 3 Single Fuse DF 4 Double Fuse Ballast 5 GEB Generic Electronic Ballast MLEBAD 9 Analog Dimming ELN Ballast Emergency Battery Back-up, Fluescent only. Receptacle GFCI Receptacle DR Duplex Receptacle Lamp LPI 8 Lamp Included LPIC 8 Lamp Included, Coated Finish BL Black BZ Bronze DDB Dark Bronze DNA Natural Alum. GN Green GR Gray SND Sand STG Steel Gray TVG Terra Verde Green WH White CF Custom Finish Optional Louvers Painted 6 /PL Louvers painted to match fixture IEC Listing International Electrotechnical Commission Notes: 1 Will be provided with coated lamps unless LPI is chosen. 2 MVOLT (120-277) available with GEB only option with Fluescent lamps. 3 SF is only available with 120, 277 347 volts on HID only. 4 DF is only available with 208, 220 240 volts on HID only. 5 GEB & MLEBAD is available with all MH lamps. 6 Louvers will be black unless otherwise specified. 7 Low Pressure Sodium units require larger louver stack. 8 LPIC recommended f all ED17 lamps. LPI recommended f T6, T4 and CFL lamps. 9 0-10 Volt remote analog dimmer system with additional supply wiring required (by others). Hydrel is an ISO 9001 Certified Manufacturer CERTIFICATIONS UL CUL LISTED WET LOCATIONS I.E.S. CUTOFF 5

12881 Bradley Avenue, Sylmar, CA 91342 T 818.362.9465 F 818.362.6548 Email: custserv@hydrel.com www.hydrel.com Fm No. 106.28 5/06 2006 Acuity Brands, Inc. All rights reserved. Hydrel is a trademark of Acuity Brands, Inc.