MULTICAL 6M2. Data sheet

Similar documents
Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

MULTICAL 62 DATA SHEET. Application

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

Heat meter (E1) θ: 2 C C. DK-0200-MI qp, p/l: See display. S/N: /K8/17 Type: 603C219. Pt500-EN Battery, 1 x D-cell

SonoMeter 30 Energy Meters

MULTICAL 602 & ULTRAFLOW

Installation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

SonoMeter 30 Energy Meters

Installation and User Guide MULTICAL 801. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

Superstatic 440. Static Heat- and Cooling Meter. Application

WZMC-402 Ultrasonic Apartment Energy Meters

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Fluidic Oscillation Compact Heat Meter

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Compact Static Heat Meter of High-Tech Composite

ULTRAFLOW type 65-S/65-R

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

RAY COMPACT ENERGY METER MECHANICAL

tprime TM Series 280T

Superstatic 749. Fluidic Oscillation Compact Heat Meter

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Heat Meter Integrator

Kamstrup Valve. Data sheet

Ultrasonic heat meter

Horizontal Distribution Units - HDU Multi-port

ULTRASONIC HEAT METER

MagFlux Q 8200 Series

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Supercal 539. Compact thermal energy meter

WESAN WPV E ELECTRONIC METER WOLTMAN

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

SonoSelect and SonoSafe energy meters

HYDRUS ULTRASONIC METER

premier product range

Turbidity and Suspended Solids Transmitter

HYDRUS ULTRASONIC METER

Online data sheet S710 E S700 EXTRACTIVE GAS ANALYZERS

Measuring capsule heat meter G54 / G55

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

EM DC Multi-Function DC Energy Meter

CORONA E ELECTRONIC METER MULTI-JET

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Analog input module. Brief description. Page 1/8. Data Sheet

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

SITRANS FUE950 *085R9430* Energy calculator type SITRANS FUE950. Operating Manual Edition 09/ Revision 03

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

Supercal 539 Universal compact heat meter

2-Color Display High-Precision Digital Pressure Switch

M-bus impeller type heat and heat/refrigeration meters

ThermoPro TM Series TP10

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

CORONA ER ELECTRONIC METER MULTI-JET

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

PROVA 1011 Solar System Analyzer

JUMO ecotrans Lf 01/02

Flow meter Type Recordall (RCDL)

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

zelsius Installation and operating manual All that counts. EnergyMetering

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Electromagnetic flowmeter. Descriptions. Specifications

Series 10-ZSE40A(F)/10-ISE40A

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Power Switching Devices

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Heating, air-conditioning, cooling

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

zelsius Installation and operating manual All that counts EnergyMetering

Service instructions. MAGNA Series 2000

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Ultrasonic filling level sensor UFM 200 / 600 C2 / C4 / R / MD

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

mass flowmeter for compressed air

D Series: UPS UPTO - 300KVA - Three / Three Phase

AC Induction Motor Controller with VCL

Marine Shaft Power Meter Product Overview

Three Phase UPS Systems Range: 10 to 500kVA

TECHNICAL DATA SHEET KVA UPS Systemss

HYDROMETER. Operating Instructions Edition 03/ Revision 05. Ultrasonic flowmeter type SHARKY 475 [ ] A5E HYDRO.PS.022.Q5.

Evaluation Certificate

INTERNATIONAL METAL ENGINEERING

DGC-2020 DIGITAL GENSET CONTROLLER

Transcription:

Data sheet MULTICAL 6M2 Tailored for mixed fluids Data loggers Info loggers Data backup in case of power failure Measurement at subzero temperatures Configurable fluid type and concentration level

Contents Calculator functions 3 Cabinet design 8 Meter data 9 Electrical data 10 Pulse connections 11 Mechanical data 12 Materials 12 GWF flow sensor 12 Order specifications 13 Dimensional sketches 14 Accessories 16 MULTICAL 6M2 Application MULTICAL 6M2 is an all-purpose energy calculator for mixed fluid applications which works together with a pulsed flow sensor and a pair of 2-wire temperature sensors. The calculator registers precise consumption throughout the whole lifetime. The calculator is maintenance-free and has a long lifetime which guarantees minimum yearly operating costs. MULTICAL 6M2 is used for heat and cooling measurements in all mixed fluid-based systems with medium temperatures from -40 C to 140 C. Functionality MULTICAL 6M2 is used together with a flow sensor and two temperature sensors. The calculator can be used with different types of flow sensors suitable for mixed fluids, such as mechanical or electronic pick-up units as well as magnetic inductive flow parts. The calculator can be used with flow parts up to qp 3,000 m³/h. The temperature sensors fitted to this calculator are Pt500 sensors. The calculator s range of communication modules makes it easy to fit the meter into various applications. The calculator can be fitted with LON, M-Bus, ModBus and BACnet MS/TP for wired communication. The calculator s info codes and data loggers make up an invaluable tool for troubleshooting, error correction and analysis of energy consumption. The info logger constantly monitors a number of key functions in the meter, such as error in the temperature measurement. In such cases, a flashing INFO and an info code appear in the display. MULTICAL 6M2 saves consumption data on a yearly, monthly, daily and hourly basis, which provides the operations manager with a complete performance analysis. In case of power failure, data is backed up. Tailored for mixed fluids Mixed fluids have a lower specific heat capacity compared to that of water. The type of antifreeze liquid and the concentration are freely programmable and thus MULTICAL 6M2 can compensate for the unique specific heat capacity in each application, ensuring a high accuracy regardless of the chemical composition or the application. 2 Kamstrup A/S 58101366_C1_GB_04.2015

Calculator functions Energy calculation MULTICAL 6M2 calculates energy based on the formula in pren 1434-1:2009 in which the international temperature scale from 1990 (ITS-90) and the pressure definition of 16 bar is used. The energy calculation can in a simplified way be expressed as: Energy = V x Θ x k. V Θ k is the supplied fluid volume is the temperature difference measured is the thermal coefficient of fluid The calculator always calculates energy in [Wh], and then it is converted into the selected measuring unit. E [Wh] = V x Θ x k x 1,000 E [kwh] = E [Wh] / 1,000 E [MWh] = E [Wh] / 1,000,000 E [GJ] = E [Wh] / 277,780 Application types MULTICAL 6M2 operates with two different energy formulas, E1 and E3, that both are calculated in parallel in connection with each integration no matter how the meter is configured. The energy types are calculated as follows: E1=V1(T1-T2)k E3=V1(T2-T1)k Heat energy (V1 in inlet or outlet) Cooling energy (V1 in inlet or outlet) Both energy types are data logged. Flow measurement MULTICAL 6M2 calculates current fluid flow according to two different principles depending on the connected flow sensor type: The flow indication of electronic flow meters is updated every 10 seconds. The flow indication of mechanical flow meters, typically with reed contact, is calculated on the basis of periodic time measurement and is updated with each volume pulse. Power measurement MULTICAL 6M2 calculates current power on the basis of current fluid flow and the temperature difference measured in connection with the latest integration. Current power is updated in the display simultaneously with the flow update. Kamstrup A/S 58101366_C1_GB_04.2015 3

Calculator functions Min. and max flow and power MULTICAL 6M2 registers minimum and maximum flow and power on a monthly as well as on a yearly basis. The registrations include max and min. flow and power values, all with date indication. These registrations can be viewed in the display or be read through the data communication, such as a communication module or via the optical communication. All max and min. values are calculated as largest and smallest average respectively of a number of current flow or power measurements. The average period used for all calculations is selected in the interval 1 1440 min. Temperature measurement MULTICAL 6M2 is available with Pt500 sensors in a 2-wire configuration. The measuring circuit includes a high resolution analog/digital converter with a temperature range of -40...140 C. Display functions MULTICAL 6M2 is equipped with a clear LC display including 8 digits, units of measurement and information panel. In connection with energy and volume readings, 7 digits are used, whereas 8 digits are used when e.g. meter number is read. When the front keys are activated, the display reacts immediately by calling other readings. The display automatically returns to the first reading 4 minutes after the latest activation of the front keys. MULTICAL 6M2 The main-key is used to switch between the primary readings. The sub-key is used to show secondary information about the selected primary reading. 4 Kamstrup A/S 58101366_C1_GB_04.2015

Calculator functions Set/reset function The set/reset function of MULTICAL 6M2 makes it possible to change a number of parameters by means of the two front keys on the calculator s front. The following parameters can be changed: Date Hour Input A (preset of register) Input B (preset of register) Meter no. of Input A Meter no. of Input B Pulse value for Input A Pulse value for Input B Primary M-Bus address Operating hour counter (reset) Info event counter (reset) Changing the above parameters requires that the installation seals are broken. Therefore, these parameters can only be set/reset by the energy supplier. Info codes MULTICAL 6M2 constantly monitors a number of important functions, e.g. power supply and temperature sensors. Should a serious error occur in the measuring system or in the installation, a flashing INFO will appears in the display whilst the error exists. The INFO panel automatically disappears when the error has been corrected. An info event logger indicates how many times the info code has been changed. The info event logger stores the latest 50 changes. An error hour counter registers the hours during which the info code exceeds zero. Info code Description Response time 0 No irregularities - 1 Supply voltage has been cut off - 8 Temperature sensor T1 outside measuring range 1 10 min. 4 Temperature sensor T2 outside measuring range 1 10 min. Kamstrup A/S 58101366_C1_GB_04.2015 5

Calculator functions Data loggers MULTICAL 6M2 contains a permanent memory (EEPROM) where the results of a number of various data loggers are stored. The meter contains the following data loggers: Data logging interval Data logging depth Logged value Yearly logger 15 years Counter registers Monthly logger 36 months Counter registers Daily logger 460 days Consumption (increase)/day Hourly logger 1392 hours Consumption (increase)/hour Info logger 50 events Info code, date, time and energy (E1/E3) Voltage supply MULTICAL 6M2 is available with battery supply, 230 VAC mains module or 24 VAC mains module. The supply modules are exchangeable under the installation seal. Plug-in modules Plug-in modules can be added to MULTICAL 6M2 both in the calculator s top (top module) and in the base unit (base modules). In this way the meter can be adapted to various applications and data reading methods. The modules can be seen in Order specifications on page 13. Programming and verification METERTOOL for HCW is a Windows based software which includes all facilities for calculator programming. If the software is used together with test equipment for MULTICAL 6M2, the calculator can be tested. Pulse inputs VA and VB MULTICAL 6M2 has two extra pulse inputs, VA and VB, to collect and accumulate pulses remotely, e.g from cold water meters and electricity meters. The pulse inputs are physically placed on the base modules. The pulse inputs VA and VB function independently of the other inputs/outputs. 6 Kamstrup A/S 58101366_C1_GB_04.2015

Calculator functions Fluid types MULTICAL 6M2 is compatible with the most commonly used antifreeze liquids, e.g. ethylene glycol and propylene glycol. The type of antifreeze liquid and the concentration are freely programmable, and thus MULTICAL 6M2 can compensate for the unique specific heat capacity in each application, ensuring a high accuracy regardless of the chemical composition or the application. From factory the calculator is programmed with a 4 digit fluid type code, which states what fluid type and concentration level (vol. %) the calculator is programmed to. The 4 digit fluid type code can be viewed in the calculator s display (reference number 71). Furthermore, the fluid type code is configurable through METERTOOL which means that you can reconfigure the chemical (fluid type) as well as the concentration level. New fluid types are added continuously, and therefore, the complete overview of compatible fluid types can be viewed online at www.kamstrup.com. 11 30 Fluid type code 11 30 Monoethylene glycol (EG) 30 % Kamstrup A/S 58101366_C1_GB_04.2015 7

Cabinet design Top module Cable relief Connector between the top and bottom Pulse outputs (CE and CV) Connector terminals for power supply/battery Connection terminals for temperature sensors (T1 + T2) Power supply/battery Connection terminals for flow sensors (V1+V2) Connection terminals for temperature sensors (T3) Cable relief Area for base module 8 Kamstrup A/S 58101366_C1_GB_04.2015

Meter data Approval EU directives No approval is available for mixed fluids, but tested in compliance with standards EN 1434:2007, pren 1434:2009 and OIML R75:2002 LVD (Low Voltage Directive) EMC (Electromagnetic Compatibility Directive) Heat meter Temperature range θ: -40 C...140 C Differential range Θ: 3 K...170 K Cooling meter Temperature range θ: -40 C...140 C Differential range Θ: 3 K...40 K The stated minimum temperatures apply to best practice. The meter has no cutoff for low ΔΘ and thus measures as low differential temperatures as 0.01 K. Temperature sensors Type 6M2-G/H Pt500 EN 60 751, 2-wire connection Typical accuracy Calculator E C ± (0.5 + 2/ΔΘ) % Sensor set (-40...140 C) E T ± (0.4 + 5/ΔΘ) % Flow sensor types Mechanical meters with reed switch Electronic meters with active 24 V pulse output Electronic pick-up units Flow sensor sizes [kwh] qp 0.6 m³/h...qp 15 m³/h [MWh] qp 0.6 m³/h...qp 1500 m³/h [GJ] qp 0.6 m³/h...qp 3000 m³/h EN 1434 designation Environmental class A and C MID designation Mechanical environment Class M1 Electromagnetic environment Class E1 and E2 Kamstrup A/S 58101366_C1_GB_04.2015 9

Electrical data Calculator data Display LCD 7 (8) digits with a digit heigth of 7.6 mm Resolution 9999.999 99999.99 999999.9 9999999 Energy units MWh kwh GJ Data logger (EEPROM) Standard 1392 hours, 460 days, 36 months, 15 years, 50 info codes Clock/calendar Data communication Power in temperature sensors Clock, calendar, leap-year compensation, target date, real-time clock with battery back-up KMP protocol with CRC16 used for optical communication and for top and base modules < 10 µw RMS EMC data Meets pren 1434-4:2009 Class C (MID Class E2) Supply Supply voltage Battery Closed circuit 3.6 VDC ± 0.1 VDC 3.65 VDC, D-cell lithium < 35 µa excluding flow sensor Replacement interval Mounted on wall 12 + 1 years @ t BAT < 30 C The replacement interval is reduced when using data modules, frequent data communication or high ambient temperature. Mains supply Insulation voltage Power consumption Backup supply 230 VAC +15/-30 %, 50/60 Hz 24 VAC ± 50 %, 50/60 Hz 4 kv < 1 W Integral super-cap eliminates operational stop-down due to short term power cuts (this only applies for supply modules type 6M2-0000-7 and 6M2-0000-8). Temperature measurement Sensor inputs T1, T2, T3 Measuring range -40 140 C Max cable lengths Pt500, 2-wire 2 x 0.25 mm²: 10 m 2 x 0.50 mm²: 20 m 10 Kamstrup A/S 58101366_C1_GB_04.2015

Pulse connections Flow measuring V1 and V2 Reed switches V1: 10-11 and V2: 69-11 24 V active pulses V1: 10B-11B and V2: 69B-79B EN 1434 pulse class IB (IA) Pulse input 680 kω pull-up to 3.6 V 12 ma at 24 V Pulse ON < 0.4 V for > 100 msec. < 4 V for > 3 msec. Pulse OFF > 2.5 V for > 100 msec. > 12 V for > 10 msec. Pulse frequency < 1 Hz < 128 Hz Integration frequency < 1 Hz < 1 Hz Electrical isolation No 2 kv Pulse inputs without bounce damping VA and VB VA: 65-66 and VB: 67-68 Water meter connection FF(VA) and GG(VB) = 71 90 Electricity meter connection FF(VA) and GG(VB) = 50 60 Pulse input 680 kω pull-up to 3.6 V 680 kω pull-up to 3.6 V Pulse ON < 0.4 V for > 30 msec. < 0.4 V for > 30 msec. Pulse OFF > 2.5 V for > 100 msec. > 2.5 V for > 100 msec. Pulse frequency < 1 Hz < 3 Hz Electrical isolation No No Max cable length 25 m 25 m Requirements to external contact Leakage current at function open < 1µA Pulse inputs with bounce damping VA and VB VA: 65-66 and VB: 67-68 Water meter connection FF(VA) and GG(VB) = 01 40 Pulse input 680 kω pull-up to 3.6 V Pulse ON < 0.4 V for > 200 msec. Pulse OFF > 2.5 V for > 500 msec. Pulse frequency < 1 Hz Electrical isolation No Max cable length 25 m Requirements to external contact Leakage current at function open < 1µA Pulse outputs CE and CV Type Pulse length External voltage Current Residual voltage Electrical isolation Max cable length Via top module 602-OC Open collector (OB) Optional 32 msec. or 100 msec. 5 30 VDC 1 10 ma U CE 1 V at 10 ma 2 kv 25 m Kamstrup A/S 58101366_C1_GB_04.2015 11

Mechanical data Environmental class Ambient temperature Protection class Storage temperature Weight Connection cables Supply cable Meets EN 1434 Class A and C 5 55 C non-condensing, closed location (indoor installation) IP54-20 60 C (drained flow meter) 0.4 kg excluding sensors and flow sensor ø3.5 6 mm ø5 10 mm Materials Top cover Base unit Print box Wall bracket PC ABS with TPE gaskets (thermoplastic elastomer) ABS Thermoplastic, PC 20 % GF GWF flow sensor GWF volume measuring meters can withstand installations where antifreeze agents are present. The measuring dynamics are, however, influenced depending on the concentration. With an antifreeze concentration: 1. Below 5 % there is no influence on the measuring dynamics. 2. At 30 % the q i value is doubled. Note: The q i increases between 5-30 %. This degradation takes place proportionally. 3. Above 30 %, we do not recommend these meters. 12 Kamstrup A/S 58101366_C1_GB_04.2015

Order specifications MULTICAL 6M2 Type 6M2- Sensor connection Pt500, 2-wire (T1-T2-T3) Pt500, 2-wire (T1-T2-T3) w/24 V pulse inputs Top module No module 0 2 pulse outputs CE and CV C Base module No module 00 M-Bus + pulse inputs (rev. B1 or higher) 20 LonWorks + pulse inputs (rev. A1 or higher) 24 BACnet MS/TP module + pulse inputs (rev. J1 or higher) 66 ModBus RTU + pulse inputs (rev. B1 or higher) 67 Supply No supply 0 Battery, D-cell 2 230 VAC isolated linear supply 7 24 VAC isolated linear supply 8 Pt500 sensor set No sensor set 00 Pocket sensor set w/1.5 m cable 0A Pocket sensor set w/3.0 m cable 0B Pocket sensor set w/5 m cable 0C Pocket sensor set w/10 m cable 0D Short direct sensor set w/1.5 m cable 0F Short direct sensor set w/3.0 m cable 0G 3 Pocket sensors in sets w/ 1.5 m cable OL 3 Short direct sensors in sets w/ 1.5 m cable Q3 Flow sensor/pick-up unit Prepared for meters w/ electronic pulse output (both V1 and V2) Prepared for meters w/reed switch output (both V1 and V2) Prepared for meters w/24 V active pulses (both V1 and V2) Supplied w/1 pcs. mechanical meter (Please specify type) Meter type Heat meter, closed system 4 Cooling meter 5 Country code (language on label, etc.) G H K L M P XX Kamstrup A/S 58101366_C1_GB_04.2015 13

Dimensional sketches Front dimensions of MULTICAL 6M2 MULTICAL 6L2 Panel mounted MULTICAL 6M2 seen from the front MULTICAL 6L2 14 Kamstrup A/S 58101366_C1_GB_04.2015

Dimensional sketches Wall-mounted MULTICAL 6M2 seen from the side Panel-mounted MULTICAL 6M2 seen from the side 52 mm Kamstrup A/S 58101366_C1_GB_04.2015 15

Accessories Description Item number D-cell battery 1606-064 230 VAC isolated linear supply 60200007000000 24 VAC isolated linear supply 60200008000000 Data cable w/usb plug 6699-098 Infrared optical reading head w/usb plug 6699-099 Infrared optical reading head w/d-sub 9F 6699-102 Data cable RS232, D-sub 9F 6699-106 Verification unit (used with METERTOOL) 6699-397/-398/-399 Temperature sensor set with connecting head (2/4 wired) 6556-4x-xxx METERTOOL HCW 6699-724 LogView HCW 6699-725 Please contact Kamstrup A/S for questions about further accessories. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 F: +45 89 93 10 01 info@kamstrup.com kamstrup.com Think forward 16 Kamstrup A/S 58101366_C1_GB_04.2015