Test report No

Similar documents
Test report No

Test report No

Test report No

European B1 Fire Rating. soft collection softwall + softblock Fire Retardant (FR) Treated textile products. molo design, ltd

Test report No

Germany B1 Fire Rating. kraft paper products. molo design, ltd Venables Street Vancouver, B.C. Canada V5L 2G7

Test report no

Test report No

Test Report No

Classification report No K1

Test report no

Test report no

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report No. AJHL FB Date: APR.06, 2016 Page 1 of 5

Test Report No. AJHL FB Date: OCT.26, 2016 Page 1 of 6

TEST REPORT Reference No. : TRHZ _R1 Date : Nov. 27, 2012 Page No.: 1 of 5

TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS

Test Report No. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )

Test Report No. AJHL FB-2 Date: OCT.24, 2016 Page 1 of 6

Catalogue Partition rooms flexibly. Protect personal privacy. Curtains. Screen Systems

Sound-absorbing spacer Sorp10

FIRE TEST REPORT FH 5154

Report Test Report

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

E/ECE/324/Rev.2/Add.117/Amend.1 E/ECE/TRANS/505/Rev.2/Add.117/Amend.1

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Title: Fire Resistance Test In Accordance With BS EN : 1999 On A Glazed Screen Assembly. WF Report No: , Issue 2. Prepared for: Date:

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT TABLE FOR AMBULANCE STRETCHER

Determination Of Fire Effluents From Products On Railway Vehicles

Confirmation: / 22 March 2013

Product Information. Bayferrox 640. Description. Specification. Brown pigment

Product Information. Bayferrox 610. Description. Specification. Specification. Brown pigment

Black pigment - High Performance micronised. Synthetic iron oxide Fe 3 O 4 Pigment black 11 (77499)

EU Mutual Recognition Technical Requirements

:... Test accortling to. ISO 4589 Part 2 : Client: Am Stadthafen Gelsenkirchen

FIRE TEST REPORT FH 5728

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

National Standard of People s Republic of China

20 HUBER+SUHNER RADOX SOLAR

EC type-examination of SITEMA Safety Brakes by DGUV Test

FLASH POINT TESTER. Instruction Manual. 0. Health and Safety Advice. 1. Introduction

Product Information. Description. Specification

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

MITRAS MATERIALS GMBH

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

VAUTH ANALYSING. TESTING. CERTIFYING. aviation components

Synthetic iron oxide α - Fe 2 O 3 Pigment red 101 (77491)

Vertex Floors Ltd. Room B & C, 15/f Hang Seng Causeway Bay Building, 28 Yee Wo Street, Causeway Bay. P.R. China. Berlin, den

TEST REPORT MEDICAL VEHICLES AND THEIR EQUIPMENT AMBULANCE STRETCHER

DNVGL-CP-0110 Edition March 2016

Test report. About the effect of Lambda System Cleaning Products. No

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

DEUTSCHE NORM DIN 8077

Technical information No. 01. IT systems. The basis for reliable power supply

Evidence of performance Reduction of impact sound pressure level by floor coverings

Product information. COLORTHERM Red 110 M. Description. Specification. Specification. Red pigment

Test Report /Al (Results with Batch 1) Vastern Timber Company Ltd. Wootton Bassett, Swindon

Product information. COLORTHERM Yellow 30. Description. Specification. Specification. Yellow pigment

CONTINUOUS IMMERSION AND DUST TEST REPORT

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Brown pigment - High Performance, special with high thermal stability

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

E/ECE/324/Rev.2/Add.106/Rev.6/Amend.5 E/ECE/TRANS/505/Rev.2/Add.106/Rev.6/Amend.5

Synthetic EP air compressor oils based on PAO, for turbo, screw, vane and piston compressors; High-performance synthetic, PAO-based hydraulic fluids

Ignition Temperatures of R1234yf

InnoBYG small scale demonstration tests - Part 1

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

ETHANOL 1100 FIREPLACE OWNER S MANUAL

RECYCLABILITY EVALUATION PROTOCOL FOR PE FILMS

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

FIRE TEST REPORT FH 5078

Approval mark PL HCR 1a A

Accreditation. a'1" ul. ( oar.hl,.n" Deutsche Akkreditieru ngsstelle G m bh. Y,/.,n" r,nn" Head of Division

FIRE PROTECTION PRODUCTS CONSIDERED FOR SURE!

Report on the product testing, monitoring and evaluation of the FPC according to the contracted supervision Product type MDF El

VdS-Guidelines for water extinguishing systems. VdS en. Sprinkler Pumps. Requirements and test methods. VdS en : (03)

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Kittec X-Line. U s e r s M a n u a l

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

Evaluation Certificate

Deutsche Akkreditierungsstelle GmbH

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

5-Layer Hot & Cold Water Piping

TECHNICAL INFORMATION

APIB Test Specification No. 00b General Part B SWISS HAIL IMPACT PROTECTION REGISTER (HSR) / 00b-18en Version 1.02

DEUTSCHE NORM DIN Passverzahnungen mit Evolventenflanken und Bezugsdurchmesser Teil 2: Nennmaße und Prüfmaße

RENOSAFE FireProtect 46, 68 Fire resistant hydraulic fluid, based on new ester and additive technology, Type HFDU

Transcription:

Exova Brandhaus Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : Brandhaus@exova.com W: www.exova.com Test report No. 2009-2211 for applying of a required Verwendbarkeitsnachweis issued 30.11.2009 Applicant: Marta Trede LG HI-MACS Project Management Gladiolenweg 3b D 65451 Kelsterbach Date of order: 04.11.2009 Date of sampling: Date of arrival: 04.11. + 16.11.2009 Date of test: 19.11. + 30.11.2009 Order no official taking out of the sample from a representative of the Bodycote Warrington Brandhaus Testing of the flammability (building class B1) according to DIN 4102-1 (Mai 1998) Description / designation of the test object HI-MACS, Natural Acrylic Stone Description of the relevant test procedure DIN 4102 Teil 1 (Mai 1998) This test report did replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049 Ust-Id Nr. DE259957713 09.12.2009

Test report No. 2009-2211 issued 30.11.2009 page 2 fom 9 1. Description of the test material 1.1 Details of the customer: HI-MACS, Natural Acrylic Stone Construction: HI-MACS, colour: Opal (S302), thickness 12 mm HI-MACS, colour: Garnet Sand (G16), thickness 12 mm HI-MACS, colour: Black Granite (G31), thickness 12 mm 1.2 At the sample preparation in the Exova Brandhaus determined values: Panel Material Sample: 1. 2. 3. Colour: white red streaked black streaked Thickness: 12 mm 12 mm 12 mm Weight: 20,8 Kg/m² 20,3 Kg/m² 20,1 Kg/m² The samples were stored before testing under climatic conditions (23 C / 50 % rel. humidity).

Test report No. 2009-2211 issued 30.11.2009 page 3 fom 9 2. Test results 2.1 Brandschachtprüfung nach DIN 4102-1 Sample A: Sample B: Sample C: HI-MACS, colour: Opal (S302) HI-MACS, colour: Garnet Sand (G16) HI-MACS, colour: Black Granite (G31) Test results of the Brandschacht tests part 1 line Measurements test sample no. A B C 1 no. test arrangement according to DIN 4102 part 15, table 1 1 2 flame height max. over lower sample edge cm 90 100 90 time 1) 9:37 9:51 8:56 3 ascertainments on the front side Flaming/glowing time 1) 1:47 2:08 2:47 4 melting / burning through time 1) 5 6 7 8 9 10 11 12 ascertainments on the back side Flaming/glowing time 1) discolouring time 1) burning droplets begin 1) extent occasional droping of material constant droping of material separating from burning sample parts begin 1) occasional separating parts constant separating parts 13 duration of burning on the sieve tray (max.) influnce on the burner flame by droping of / separating material 14 time 1) earlier end of test 15 end of the fire scenario on the sample 1) 16 time of a possible resulted test stop 1) no no no no no no 10:15 10:24 10:33 1) time from start of test

Test report No. 2009-2211 issued 30.11.2009 page 4 fom 9 Test results of the Brandschacht tests part 2 line Measurements test sample no. A B C flaming after end of test 17 duration 0:15 0:24 0:33 18 number of sample 4 4 4 19 front side of sample no no no 20 backside of sample 21 flame length cm 40 40 40 22 23 24 25 26 27 glowing after end of test duration number of sample place of occurrence lower sample part upper sample part front side of sample backside of sample min. s --/-- --/-- --/-- --/-- --/-- --/-- 28 29 30 smoke density < 400 % x min 5 1 1 > 440 % x min --/-- --/-- --/-- diagram in annex no. 1 2 3 31 32 33 34 35 36 residual length single results average of the single results foto of the sample on page smoke temperature max. of the average results time 1) diagram in annex no. cm cm C 53 / 54 55 / 54 50 / 53 54 / 55 52 / 52 50 / 50 54 53 51 5 5 5 168 172 183 9:55 9:53 9:55 1 1 1 1) time from start of test Remarks: no special observations. Because of the average residual length of all tests was > 45 cm, the quantity of tests could be reduced to three tests.

Test report No. 2009-2211 issued 30.11.2009 page 5 fom 9 Appearance of sample A after the Brandschacht test Appearance of sample B after the Brandschacht test Appearance of sample C after the Brandschacht test

Test report No. 2009-2211 issued 30.11.2009 page 6 fom 9 2.2 Normal flammabilty test according to DIN 4102-1 Test with edge ignition without deposit Flame application on: lower sample edge Test direction: in direction of production HI-MACS, colour: Opal (S302): Sample-no. Time from start of test 1 2 3 4 5 Ignition point [s] - - - - - Reaching the measuring mark within 20 seconds no no no no no Self extinguishing of the flame [s] 15 15 15 15 15 Max. flame height [mm] 15 15 15 15 15 Time [s] 15 15 15 15 15 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material no no no no no Time [s] - - - - - Remarks: none HI-MACS, colour: Garnet Sand (G16): Sample-no. Time from start of test 1 2 3 4 5 Ignition point [s] - - - - - Reaching the measuring mark within 20 seconds no no no no no Self extinguishing of the flame [s] 15 15 15 15 15 Max. flame height [mm] 15 15 15 15 15 Time [s] 15 15 15 15 15 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material no no no no no Time [s] - - - - - Remarks : none

Test report No. 2009-2211 issued 30.11.2009 page 7 fom 9 HI-MACS, colour: Black Granite (G31): Sample-no. Time from start of test 1 2 3 4 5 Ignition point [s] - - - - - Reaching the measuring mark within 20 seconds no no no no no Self extinguishing of the flame [s] 15 15 15 15 15 Max. flame height [mm] 15 15 15 15 15 Time [s] 15 15 15 15 15 End of afterflaming [s] - - - - - End of afterglowing [s] - - - - - Flames extinguished after [s] - - - - - Smoke development (visuell impression) low smoke production Separating from burning material no no no no no Time [s] - - - - - Remarks : none

Test report No. 2009-2211 issued 30.11.2009 page 8 fom 9 Appearance of the sample after the small burner test: HI-MACS, colour: Opal (S302): HI-MACS, colour: Garnet Sand (G16): HI-MACS, colour: Black Granite (G31)

Test report No. 2009-2211 issued 30.11.2009 page 9 fom 9 Assessment The in chapter one described material fulfils the requirements of the building class B2 according to DIN 4102-1 (Mai 1998). The determined test results show that the material fulfils also the requirements of the building class according to DIN 4102-1 (Mai 1998). B1 Special comment The fire test result is only valid for the in chapter one described material, in the tested thicknesses, square weights and colours, in free hanging configuration,. The distance to other plane material must be more then 40 mm. In accordance to the experience of the test institute the test result is also valid for the colour amongst. The material wasn't tested after an outside storage. In combination with other materials (for example coatings, deposits) the burning behaviour could be influenced unfavourable so that the classification above is valid any longer. According to DIN 4102-1 the burning behaviour in combination with other materials has to be tested separately. This test certificate did replace the required Verwendbarkeitsnachweis. It is only used for issuing the Verwendbarkeitsnachweis. Frankfurt, the 30.11.2009 P. Scheinkönig Dipl.-Ing. H. Bräuer Tester in charge Head of laboratory This Test report is valid until 29.11.2014. The results of the tests relate only to the behaviour of the test sample which is designated on the top. Test reports are only allowed to be published or reproduced, changed in form and tenor without permission of the Exova Brandhaus. The abridged account of a test report is only allowed with the agreement of the Exova Brandhaus. This Test report is a translation of the German version 2009-2211 (issued 30.11.2009). In case of doubt only the German version is valid This test report contains 9 pages and 3 annexes.

Annex 1 to the Test report No. 2009-2211 dated 30.11.2009 Sample A:

Annex 2 to the Test report No. 2009-2211 dated 30.11.2009 Sample B:

Annex 3 to the Test report No. 2009-2211 dated 30.11.2009 Sample C: