HD [ GB ] Tipping bucket rain gauge

Similar documents
Data-Logging Rain Gauge PRODUCT MANUAL

STORM Guardian. Operator s Handbook

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

Kalyx-RG Rain Gauge User Manual

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

TABLE OF CONTENTS. Contents CONTENTS... PAGE. Jan 2006 COPYRIGHT. Tipping Bucket Rain Gauges User Manual. Tipping Bucket Rain Gauges User Manual

RS-110 Rainfall Sensor Installation Guide

TR-4 Tipping Bucket Rain Gauge User s Manual

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

Rain Collector (#7857 & 7857M)

Digital Tipping Bucket Rain Collector PRODUCT MANUAL

SBS Range Rain Gauge User Manual

METEOROLOGICAL INSTRUMENTS

AV-W. Wind Speed and Wind Speed & Direction Sensors

ARG100 Rain Gauge User Manual

HUMIDITY / TEMPERATURE TRANSMITTER

INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

INSTRUCTION MANUAL. Wireless Level Indicator

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX)

SITESTAR ELECTRONICS CABINET DESCRIPTION

Low Profile, Single Output, Non-Contact Angle/Position Sensors

TCM-2 Thyristor DATA Control SHEETModule DATA SHEET. TCM-2 Thyristor Control Module

4 submersible pumps powered by renewable energy sources

Wireless Temperature/Humidity Station

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

TCM-2 Thyristor DATA Control SHEETModule DATA SHEET. TCM-2 Thyristor Control Module

Instructions for use CONTENTS

Ultrasonic Two-Wire Point Level Control

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Weather Replacement Parts 2018

INSTALLATION GUIDE Ultrasonic Sensors Series UX micro

HOBO RX Wireless Sensor Network RXW Davis 0.01" or 0.2 mm Rain Gauge Sensor (RXW-RGx-xxx) Manual

Measuring capsule heat meter G54 / G55

Heat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1

ECONOMISER SERIES E2T USER MANUAL

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

4 submersible pumps with integrated electronics powered by renewable energy sources ENGLISH

SonoMeter 30 Energy Meters

HD 2114P.0 HD 2114P.2 HD 2134P.0 HD 2134P.2

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Fluidic Oscillation Compact Heat Meter

Rain Gauge RG13 and RG13H USER'S GUIDE

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Installation & Calibration Manual

Lift-N-Glide Manual. Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No:

TECHNICAL DATA SHEET KVA UPS Systemss

ULTRASONIC FLOW SENSOR IFX-M4-01

METEOROLOGICAL INSTRUMENTS

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Compact Static Heat Meter of High-Tech Composite

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

EZ-MOUNT WEATHER STATION

MOD. MASTER METER INSTALLATION OPERATION AND MAINTENANCE. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Resistance thermometer with digital indicator Model TR75, battery operation

Wind Speed/Direction Smart Sensor (Part # S-WCA-M003)

LINEAR ACTUATORS INDEX

Self-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual

DR. ALFRED MÜLLER METEOROLOGISCHE INSTRUMENTE KG R. FUESS. Windmeasuring System AEW20

INSTRUCTION MANUAL Oil level with pointer indicator

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

4 variable speed submersible pumps

Special Purpose Transmitters

Appendix. Clearance. Skewed profiles. Application Schematics

DIGI-TEL THERMOMETERS

RMF SYSTEMS CONDITION MONITORING CENTER PURE POWER

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

Signet Pressure Transmitter

Encoder Installation Manual Dynapar brand SERIES M21 Modular Encoder

DIG Corporation Irrigation product Specifications

Digital Time Switches

Positive Displacement Flowmeters GM020 series instruction manual

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

R1000-R1500 Range. Automatic Labelling Machine. Wine Industry

TEMPERATURE - HUMIDITY VAISALA HMP155

Wind direction sensors. User s manual

METEOROLOGICAL INSTRUMENTS

mass flowmeter for compressed air

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

USB3.0 For Active Optical Cable SPECIFICATIONS

Screw jacks MA Series

CAN and Serial Instrumentation

M ilitary G rade U ninterruptible P ower S upply

Servo-Torq Rim block cutter With integral roller in-feed & exit conveyor belt

SonoMeter 30 Energy Meters

UPG1000 & Windshield. Manual

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

EU RO Mutual Recognition Technical Requirements

Integrated temperature test and calibration bench Model CBS-SC4000

OPERATING INSTRUCTIONS Flow sensors with connecting flanges DN CE

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

4HS MultiPower Submersible Pumps. Installation and Operating Manual. M u l t i P o w e r. man4hs_mp_11_eng

MH2 For automatic security cover decks of pools

The Solar Power Kit includes the following components. Please be sure you have all listed components before beginning. 5/16" x 2" Carriage Bolt

Transcription:

HD 2015 [ GB ] Tipping bucket rain gauge

[ GB ] [ GB ] Description The HD2015 is a reliable and sturdy bucket rain gauge, entirely constructed of corrosion resistant materials in order to guarantee its durability. To ensure accurate measurements even with low temperature climatic conditions or during and after precipitations of snow, a version with heating system, automatically activated around +4 C, has been developed to prevent snow deposits and ice formations. The rain gauge is formed by a metal base on which a tipping bucket is set. The rain collector cone, fi xed to the aluminium cylinder, channels the water inside the tipping bucket: once the predefi ned level is reached, the calibrated bucked rotates under the action of its own weight, discharging the water. During the rotation phase, the normally closed reed contact opens for a fraction of a second, sending an impulse to the counter. The quantity of rainfall measured is based on the count of the number of times the bucket is emptied: the reed contacts, normally closed, open at the moment of the rotation between one bucket s section and the other. The number of impulses can be detected and recorded by a data logger such as the HD2013-DB or by a pulse counter. A removable fi lter for periodic cleaning and maintenance is inserted in the water collector cone so as to prevent leaves or other elements blocking the end of the hole. For a better water fl ow, the collecting cone is treated with a non-stick coating. The version with heating option HD2015R works with 12 Vdc or 24 Vdc direct voltage (to be specified at the time of order) and absorbs about 50 W. The heating system is activated around +4 C. When submitting your order, it is possible to request a bird dissuader, made of eight 3 mm diameter spikes, 60 mm in height, to be installed on the rain gauge. Technical characteristics HD2015R HD2015 Power supply 12 Vdc or 24 Vdc ± 10% / 50 W (to be specifi ed at the time of order) --- Type of output contact NC contact (opens during tipping) Resolution 0.1-0.2 or 0.5 mm/tip to be specified at the time of placing the order See the typical normalized curve in fig. 1. The curve is normalized to the resolution 0.200 mm/tip @ Accuracy 50 mm/h. If the HD2013-DB data logger is used, the measurement can be automatically corrected according to the curve. Operating temperature range -20 C...+60 C +4 C +60 C Heating intervention temperature +4 C --- Protection degree IP 64 Collector area 200 cm 2 Minimum section of the wires of the connecting cable 0.5 mm 2 for the version without heating system (HD2015) 2.5 mm 2 for the version with heating system (HD2015R) Resolution (mm/tip) 0.212 0.209 0.206 0.203 0.200 0.197 0.194 0.191 0 25 50 75 100 125 150 175 200 Rainfall rate (mm/h) Fig. 1 - Resolution as a function of the rainfall rate Installation and maintenance The rain gauge is supplied already calibrated at 0.1-0.2 or 0.5 mm of rain per tip of the bucket: the calibration value is shown on the instrument label. The instrument must be installed in an open area, away from buildings, trees, etc., ensuring that the space above is free from objects which may obstruct the rain measurements and placed in an easily accessible position for periodical cleaning of the fi lter. Avoid installations in areas exposed to wind gusts, turbulences (for example on the top of a hill) as they may distort the measurements. The rain gauge can be installed on the ground or 500 mm off the ground. Other sizes of the support for installation off the ground are available upon request. For the installation on the fl oor, three adjustable support feet are supplied, so that the instrument can be levelled correctly, and also proper holes for a possible fi xing on a fl oor. For installations off the ground, a fl ange to be fi xed to the base of the instrument, where the support clamp must be inserted, is supplied; the clamp ends either with a fl ange so that it can be fi xed to the fl oor, or with a tip to be driven into the ground. For the various fastening systems please refer to the fi gures 5, 6, 7 and 8. In order to make the tipping device properly working and the measurements correct, it is important that the instrument is placed perfectly levelled. The base of the rain gauge is fi tted with a bubble level. For the installation, unscrew the three screws from the base of the cylinder that supports the water collector cone (see fi g. 2). A heating resistor is placed around the cone in the HD2015R version. The heater is automatically disconnected when the cone is lifted up. Electrical connection For the version without heating system, use a 2-wire cable with 0.5 mm 2 minimum wires section; for the version with heating system, use a 4-wire cable with 2.5 mm 2 minimum wires section. Use a shielded cable over long distances. Slide the cable through the cable gland and fasten it with the cable fastener located near the entry hole, at the base of the rain gauge. Unscrew the terminal block protection cover and perform the connections as shown in fi gure 2. The rain gauge output, indicated in point 1 of the drawing below, must be connected to the input of the HD2013-DB rain gauge data logger (please see the details in the manual of the data logger) or to a pulse counter or to a data logger. The heated version requires power for the resistors (12 Vdc or 24 Vdc depending on the version supplied): perform the connection as indicated at point 2 of fi g. 2. If the connections are correctly set, the LED placed near the terminals will be lit up. Fig. 2 - Electrical connections (version with heating system)

Tipping bucket The tipping bucket is locked during the transport of the rain gauge. To unlock the bucket, remove the holders as shown in fig. 3 here below. For the transport For the operating mode Fig. 3 - Locking and unlocking the tipping bucket The oscillation of the tipping bucket can be adjusted through the two threaded rods located at the sides of the bucket, as illustrated in fig. 4. Fig. 5 - Mechanical dimensions, installation modes Fig. 4 - Adjustment of the tipping bucket Fig. 6 - Base for installation on the floor (HD2013.78)

Maintenance Verify periodically the cleanliness status of the filter; check that there is no presence of debris, leaves, dirt in the lower filter or anything else that might obstruct the flowing of water. Check that the tipping bucket contains no deposits of dirt, sand or any other obstruction. If necessary, the surfaces can be cleaned with non aggressive detergents. Fig. 7 - Installation on the floor 1: magnet 2: tipping bucket 3: bearing 4: bush 5: spacer 6: screw 7: cover 8: screw 9: nut 10: filter 11: conveyor 12: circuit 13: washer 14: screw 15: contact 16: connector 17: screw 18: cable 19: heater 20: lock nut 21: cable gland 22: junction 23: support 24: screw 25: base 26: bush 27: screw 28: screw 29: washer 30: knob 31: spirit level 32: screw 33: screw 34: support 35: guide Fig. 9 - Exploded view of the lower part (version with heating system) Fig. 8 - Installation off the ground

PURCHASING CODES HD2015: Tipping bucket rain gauge, area 200 cm 2, for temperatures from +4 C to +60 C. Resolution to be specified upon request at the time of placing the order: 0.1-0.2 or 0.5 mm. Output contact normally closed. HD2015R: Tipping bucket rain gauge, area 200 cm 2, with heating system for temperatures from 20 C to +60 C. Resolution to be specified upon request at the time of placing the order: 0.1-0.2 or 0.5 mm. Output contact normally closed. Power supply voltage: 12 Vdc or 24 Vdc ± 10% (to be specified at the time of placing the order) / absorbed power 50 W. HD2013.18: Bird dissuader. HD2015.5K: Kit of accessories for the installation of the rain gauge raised 500 mm off the ground. Anodized aluminum support staff L=500 mm. HD2013.5K1: Kit of accessories for the installation of the rain gauge raised 1 m off the ground. Anodized aluminum support staff L=1 m. HD2013.5K2: Kit of accessories for the installation of the rain gauge raised 2 m off the ground. Anodized aluminum support staff L=2 m, accessories HD2003.75K for bracing the mast for installation with pegs on the ground. HD2013.5K3: Kit of accessories for the installation of the rain gauge raised 2 m off the ground. Anodized aluminum support staff L=2 m, accessories HD2003.78K for bracing the mast for installation on the floor. HD2013.64K: Kit of accessories for securing the rain gauge on the top of the mast; it allows the levelling. To combine with the mast L=500mm, 1m or 2m. HD2013.75: Base with tip for the ground to support the rain gauge installed off the ground (to combine with the kit of accessories HD2015.5K ). HD2013.78: Flat base for fastening the support of the rain gauge raised above ground (to combine with the kit of accessories HD2015.5K ). HD2013-DB: Rain gauge data logger. With backlit LCD. Detects and stores up to 32.255 pulses produced by the bucket emptying. Resolution configurable from 0.050 to 1.599 mm/pulse. Isolated RS232 serial output. IP 67 protection degree. Powered by a 3.6 V lithium battery. Supplied with: internal not rechargeable lithium thionyl chloride (Li-SOCl 2 ) battery (BAT-2013DB), HD32MTLogger software, 4-pole M12 female connector (FCM12.4). HD2013.77/40: Clamping for fixing the data logger to the Ø 40 mm support staff of the rain gauge. The use of two cross-connected clampings allows the fixing of a transverse mast for the installation of other sensors (e.g. solar radiation sensors, etc.). 1: ring 2: funnel 3: heater 4: housing 5: screw 6: connector 7: contact 8: nut 9: washer 10: gasket 11: birds dissuader 12: nozzle 13: pin 14: tip 15: filter 16: filter support 17: filter 18: screw Fig. 10 - Exploded view of the upper part (version with heating system) Detail of the bubble level

Manufacture of portable, bench top and process scientific instruments Current and voltage loop transmitters and regulators Temperature - Humidity, Dew point - Pressure - CO, CO 2 Air speed - Light - Optical Radiation Acoustics - Vibration Data logger - Data logger wireless Microclimate ph - Conductivity - Dissolved Oxygen - Turbidity Elements for weather stations LAT N 124 Signatory of EA, IAF and ILAC Mutual Recognition Agreements Temperature - Humidity - Pressure - Air speed Photometry/Radiometry - Acoustics CE CONFORMITY Safety: EN61000-4-2, EN61010-1 Level 3 Electrostatic discharge: EN61000-4-2 Level 3 Electric fast transients: EN61000-4-4 Level 3, EN61000-4-5 Level 3 Voltage variations: EN61000-4-11 Electromagnetic interference susceptibility: IEC1000-4-3 Electromagnetic interference emission: EN55022 class B RoHS 2002/95/EC Delta Ohm srl - Via G. Marconi, 5-35030 Caselle di Selvazzano (Pd) - Italy Tel. 0039 0498977150 r.a. Fax 0039 049635596 - E-mail: info@deltaohm.com Web Site: www.deltaohm.com 03 24.14