MAPNET II Transceiver Installation Instructions

Similar documents
Audio Operator Interface Installation Instructions

Expansion Signal (XSIG) Card Installation Instructions

Digital/Analog Amplifiers Installation Instructions

LED/Switch Modules Installation Instructions

Flex Amplifiers Installation Instructions

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

LCD Annunciator Installation Instructions

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

BroadBand PowerShield. 20 AHr Battery. User Manual

INTECH Micro 2300-RTD6

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

920i Programmable HMI Indicator/Controller Deep Enclosure Installation Instructions PNs 82455, 82456, 82457, 82458, 82459, 82460

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Electrical Installation

Discrete Output Modules IC697MDL753

AGCO América do Sul (Factory Install) Installation Manual SP01

TC26-B Vehicle Sensor

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

TRAC-Station BT Installation Instructions

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

A419ABG-3C Electronic Temperature Control

Rogator Passive Roll (2012+) 3 Height Sensors Installation Manual RG10

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

AIS 5000 UPS kva 480 V. Installation Manual

Eclipse Plus VA UPS and Surge Suppressor User s Manual

FCA2016-U1 RS485 class A module (isolated) Mounting Installation

2O3D3-19A REVB MOUNTING

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Nitro (4000 Series) Installation Manual NT04

Miller Condor & New Holland Rear Mount Truss Boom Installation Manual MC02

SPACESAVER EC-300 A ELECTRICS

Installation Instructions

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Rogator Passive Roll (2012+) 5 Height Sensors Installation Manual RG11

Sentinel Field Satellite Controller

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

825-P Modular Protection System for motors Specification Guide

DOOR SAFETY KIT INSTALLATION MANUAL

OWNER'S OPERATING MANUAL

John Deere (4730 & 4830) with Proportional Main Lift Installation Manual JD08

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

User Manual. Solar Charge Controller 3KW

FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Operating and Installation Instruction Manual

2904 Power Supply Installation Instructions I-EA00041

E.S.P. Embedded Sensing Probes for Motor Brushes

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

PVM 220 Installation Guide

IntelliTouch Expansion Center Kit

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Method Of Procedure For Retrofitting ECS Power Systems (CC )

Electrical Components

Powerware Vdc Extended Battery Cabinet User s Guide.

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

How to Install and Remove a standard Teletrac Transceiver.

INSTALLATION INSTRUCTIONS

Installing Power Components

PMC-MC-X2-Chassis PMC-MC-X4-Chassis

Direct Communication Module

SS & SS SOFT-START v3.0 ASSEMBLY & INSTALLATION INSTRUCTIONS

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

Uninterruptible Power Supply

Excel 15 W7760A BUILDING MANAGER

Demarcation Fuse Alarm Panel

Lumination TM LED Luminaire LUR Series

WARRANTY INFORMATION...

SPECIAL SPECIFICATION 6894 Communication Cabinet

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Safety Precautions Product Contents Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wire Legend Power Wiring

LED Driver Linear / area dimming

BAPI-Stat 3 Room Sensor

6K-SSR-RACK08. 8-solid state relay accessory board for use with PCI-DAS6000 Series and PCI-DAC6700 Series boards. User's Guide

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Case IH (4420, 3320) Installation Manual CS03

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

L5000 Plus. Installation & Setup Guide

Power and Cooling. Chassis Power System

LT Charging Cart for Laptops

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

TRAC-3 TENSION READOUT AND CONTROL

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Top Air (TA 1200/1600, 80/90 Boom) Installation Manual TA01

MOTORTRONICS Solid State AC Motor Control

NetSure SERIES -48 VDC Power Distribution System. Installation and User Manual (UM ), Revision A

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Transcription:

MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II Transceiver Card for 4100 Back Boxes (PID series 2975-91xx) 4100-9802 MAPNET II Transceiver Card for 4100 Back Boxes (aftermarket) 4100-3102 MAPNET II Transceiver Card for 4100U/4100ES Back Boxes (PID series 2975-94xx) 4100-9812 MAPNET II Transceiver Card for 4100U/4100ES Back Boxes (aftermarket) Related Documentation Field Wiring Diagram for 4100 Power Limited (841-731) or, Field Wiring Diagram for 4100 Non Power Limited (841-995) 4100ES Fire Alarm System Installation Guide (574-848) In this Publication This publication discusses the following topics: Topic See Page # Cautions and Warnings 2 Overview 3 Setting the Card Address Switch 4 Removing/Installing JW1 and JW2 6 Installing Motherboards into 2975-91xx Back Boxes (4100) 7 Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES) Installing the Daughter Card 16 Wiring the MAPNET Channel 17 Signal and Power Connections 21 11 2000, 2008, 2011 SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license. 579-222 Rev. C

Cautions and Warnings Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED- Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. EYE SAFETY HAZARD - Under certain fiber optic application conditions, the optical output of this device may exceed eye safety limits. Do not use magnification (such as a microscope or other focusing equipment) when viewing the output of this device. FCC RULES AND REGULATIONS PART 15 - This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SYSTEM REACCEPTANCE TEST AFTER SOFTWARE CHANGES - To ensure proper system operation, this product must be tested in accordance with NFPA72-1996, Chapter 7 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known to be affected by a change must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. 2

Overview General Information The MAPNET Transceiver Card consists of two cards: a motherboard that mounts into either a CPU bay or an expansion bay and a daughter card that mounts into the motherboard. General capabilities of the MAPNET Transceiver Card include: Connects up to 127 addressable MAPNET devices to the 4100. Supports either Class A or Class B wiring Power Specifications The MAPNET Transceiver Motherboard provides isolated 36 VDC power for the MAPNET channel. This power has the following specifications. Output Voltage: +36 VDC +5% / -7.5% @ up to 500 ma Voltage Ripple: 100 mv RMS Environmental Requirements The environment in which the transceiver card is mounted must be within the following range. Temperature: 32 F to 120 F Humidity: 85% Relative Humidity @ 86 F 3

Setting the Card Address Switch Switches Switch SW1 on the MAPNET Transceiver Daughter Card is a bank of eight dip switches. From left to right (see figure below) these switches are designated as SW1-1 through SW1-8. The function of these switches is as follows: SW 1-1. This switch sets the baud rate for the serial communication line running between the daughter card and the 4100 CPU. Set this switch to ON. SW1-2 through SW1-8. These switches set the card s address within the 4100 FACP. (These switches must be set to the value assigned to the card by the Programmer.) Refer to Table 1 for a complete list of the switch settings for all of the possible card addresses. Move a switch to the down position to turn it ON or to the up position to turn it OFF. FigureTag FD9-222-01 Baud Rate Switch (SW 1-1) Must Be Set to ON Dip Switches 1-2 through 1-8 set the Card Address. Figure shows an Address of 3. Refer to Table 1 for switch settings. OFF ON 1 2 3 4 5 6 7 8 Figure 1. DIP Switch SW1 4

Setting the Card Address Switch, Continued Switches (continued) Table 1. 4100 Daughter Card Addresses Address SW 1-2 SW 1-3 SW 1-4 SW 1-5 SW 1-6 SW 1-7 SW 1-8 Address SW 1-2 SW 1-3 SW 1-4 SW 1-5 SW 1-6 SW 1-7 SW 1-8 1 ON ON ON ON ON ON OFF 61 ON OFF OFF OFF OFF ON OFF 2 ON ON ON ON ON OFF ON 62 ON OFF OFF OFF OFF OFF ON 3 ON ON ON ON ON OFF OFF 63 ON OFF OFF OFF OFF OFF OFF 4 ON ON ON ON OFF ON ON 64 OFF ON ON ON ON ON ON 5 ON ON ON ON OFF ON OFF 65 OFF ON ON ON ON ON OFF 6 ON ON ON ON OFF OFF ON 66 OFF ON ON ON ON OFF ON 7 ON ON ON ON OFF OFF OFF 67 OFF ON ON ON ON OFF OFF 8 ON ON ON OFF ON ON ON 68 OFF ON ON ON OFF ON ON 9 ON ON ON OFF ON ON OFF 69 OFF ON ON ON OFF ON OFF 10 ON ON ON OFF ON OFF ON 70 OFF ON ON ON OFF OFF ON 11 ON ON ON OFF ON OFF OFF 71 OFF ON ON ON OFF OFF OFF 12 ON ON ON OFF OFF ON ON 72 OFF ON ON OFF ON ON ON 13 ON ON ON OFF OFF ON OFF 73 OFF ON ON OFF ON ON OFF 14 ON ON ON OFF OFF OFF ON 74 OFF ON ON OFF ON OFF ON 15 ON ON ON OFF OFF OFF OFF 75 OFF ON ON OFF ON OFF OFF 16 ON ON OFF ON ON ON ON 76 OFF ON ON OFF OFF ON ON 17 ON ON OFF ON ON ON OFF 77 OFF ON ON OFF OFF ON OFF 18 ON ON OFF ON ON OFF ON 78 OFF ON ON OFF OFF OFF ON 19 ON ON OFF ON ON OFF OFF 79 OFF ON ON OFF OFF OFF OFF 20 ON ON OFF ON OFF ON ON 80 OFF ON OFF ON ON ON ON 21 ON ON OFF ON OFF ON OFF 81 OFF ON OFF ON ON ON OFF 22 ON ON OFF ON OFF OFF ON 82 OFF ON OFF ON ON OFF ON 23 ON ON OFF ON OFF OFF OFF 83 OFF ON OFF ON ON OFF OFF 24 ON ON OFF OFF ON ON ON 84 OFF ON OFF ON OFF ON ON 25 ON ON OFF OFF ON ON OFF 85 OFF ON OFF ON OFF ON OFF 26 ON ON OFF OFF ON OFF ON 86 OFF ON OFF ON OFF OFF ON 27 ON ON OFF OFF ON OFF OFF 87 OFF ON OFF ON OFF OFF OFF 28 ON ON OFF OFF OFF ON ON 88 OFF ON OFF OFF ON ON ON 29 ON ON OFF OFF OFF ON OFF 89 OFF ON OFF OFF ON ON OFF 30 ON ON OFF OFF OFF OFF ON 90 OFF ON OFF OFF ON OFF ON 31 ON ON OFF OFF OFF OFF OFF 91 OFF ON OFF OFF ON OFF OFF 32 ON OFF ON ON ON ON ON 92 OFF ON OFF OFF OFF ON ON 33 ON OFF ON ON ON ON OFF 93 OFF ON OFF OFF OFF ON OFF 34 ON OFF ON ON ON OFF ON 94 OFF ON OFF OFF OFF OFF ON 35 ON OFF ON ON ON OFF OFF 95 OFF ON OFF OFF OFF OFF OFF 36 ON OFF ON ON OFF ON ON 96 OFF OFF ON ON ON ON ON 37 ON OFF ON ON OFF ON OFF 97 OFF OFF ON ON ON ON OFF 38 ON OFF ON ON OFF OFF ON 98 OFF OFF ON ON ON OFF ON 39 ON OFF ON ON OFF OFF OFF 99 OFF OFF ON ON ON OFF OFF 40 ON OFF ON OFF ON ON ON 100 OFF OFF ON ON OFF ON ON 41 ON OFF ON OFF ON ON OFF 101 OFF OFF ON ON OFF ON OFF 42 ON OFF ON OFF ON OFF ON 102 OFF OFF ON ON OFF OFF ON 43 ON OFF ON OFF ON OFF OFF 103 OFF OFF ON ON OFF OFF OFF 44 ON OFF ON OFF OFF ON ON 104 OFF OFF ON OFF ON ON ON 45 ON OFF ON OFF OFF ON OFF 105 OFF OFF ON OFF ON ON OFF 46 ON OFF ON OFF OFF OFF ON 106 OFF OFF ON OFF ON OFF ON 47 ON OFF ON OFF OFF OFF OFF 107 OFF OFF ON OFF ON OFF OFF 48 ON OFF OFF ON ON ON ON 108 OFF OFF ON OFF OFF ON ON 49 ON OFF OFF ON ON ON OFF 109 OFF OFF ON OFF OFF ON OFF 50 ON OFF OFF ON ON OFF ON 110 OFF OFF ON OFF OFF OFF ON 51 ON OFF OFF ON ON OFF OFF 111 OFF OFF ON OFF OFF OFF OFF 52 ON OFF OFF ON OFF ON ON 112 OFF OFF OFF ON ON ON ON 53 ON OFF OFF ON OFF ON OFF 113 OFF OFF OFF ON ON ON OFF 54 ON OFF OFF ON OFF OFF ON 114 OFF OFF OFF ON ON OFF ON 55 ON OFF OFF ON OFF OFF OFF 115 OFF OFF OFF ON ON OFF OFF 56 ON OFF OFF OFF ON ON ON 116 OFF OFF OFF ON OFF ON ON 57 ON OFF OFF OFF ON ON OFF 117 OFF OFF OFF ON OFF ON OFF 58 ON OFF OFF OFF ON OFF ON 118 OFF OFF OFF ON OFF OFF ON 59 ON OFF OFF OFF ON OFF OFF 119 OFF OFF OFF ON OFF OFF OFF 60 ON OFF OFF OFF OFF ON ON 5

Removing/Installing JW1 and JW2 Overview If the system has four-wire devices (non-isolated), remove or install pluggable jumpers JW1 and JW2, which are located on the MAPNET Transceiver Motherboard, as follows: If only two-wire devices (IAMs and detectors) are on the MAPNET channel, make sure a jumper is installed in JW2 and remove the jumper from JW1. (A resistance of 50 K Ohms or less between Earth and any of the four MAPNET comm. lines causes the motherboard to detect an Earth Trouble on a system with two-wire devices.) If four-wire devices (ZAMs, sounder bases, relay bases) are on the MAPNET channel, remove the jumper from JW2 and make sure a jumper is installed in JW1. This disables the MAPNET Earth detect and ties it to the main system s Earth detect circuit. Refer to Figure 2 for the locations of jumpers JW1 and JW2. Figure 2. Locations of Jumpers JW1 and JW2 6

Installing Motherboards into 2975-91xx Back Boxes (4100) Overview The MAPNET transceiver modules can be mounted to either 4100 Back Boxes (PID series 2975-91xx) or 4100U/4100ES Back Boxes (PID series 2975-94xx). The 4120/4100-0110 and 4100-9802 versions are used with 4100 Back Boxes. The 4100-3102 and 4100-9812 versions are used with 4100U/4100ES Back Boxes. This section covers 4120/4100-0111and 4100-9802 module mounting into 4100 Back Boxes. Installing into a 2975-91xx Master Controller Bay Use the following guidelines and instruction when installing into a master controller bay. If the 575-274 Master Motherboard is used, it must be installed in the leftmost position of this bay. If the 575-274 Master Motherboard is not used, the CPU motherboard must be installed in the leftmost position of the bay. The power supply must be installed in the rightmost position of the bay. Relay cards must be installed in the slots immediately to the left of the power supply. This is necessary to allow for the proper routing of non-power limited wiring (120 VAC wiring connected to the relay card). If used, the Class B motherboard (575-275) must be installed to the left of the relay cards. If a physical bridge is used with the Class B motherboard, it must be to the right of any motherboards using NICs. This allows for earth ground detection via the physical bridge. Install the motherboard as described below. 1. Orient the motherboard so that the connector labeled J1 is on the right and the header labeled P1 is on the left. 2. Slide the motherboard you are installing to the left until the pins are completely inserted in the connector of a previously installed motherboard. 3. Secure the motherboard to the chassis with six torx screws. CPU or 575-274 Motherboard The motherboard can be installed in any of these slots. If the bay has relay cards, they must be installed to the immediate left of the power supply. P1 Power Supply J1 Figure 3. Installing the Motherboard into a 4100 CPU Bay 7

Installing Motherboards into 2975-91xx Back Boxes (4100), Continued Installing into a 2975-91xx Expansion Bay Review the following guidelines before mounting the motherboard into a 2975-91xx Expansion Bay. If a power supply is installed in the bay, it must be installed on the far right of the bay and any relay modules must be installed in the slots immediately to its left. Relay cards must be installed in the rightmost possible slots. This is necessary to allow for the proper routing of non-power limited wiring (typically 120 VAC wiring), which could be connected to a relay module. If a 4100-0155 SDACT or a 4100-0153 CCDACT is installed in the bay, it must be installed in the far left or far right slot. Neither of these modules contains the J1 or P1 connectors, which are used to distribute power and communications to adjacent modules. Use the following directions and Figure 4 to install a motherboard into an expansion bay. 1. Orient the motherboard with the connector labeled J1 on the right and the header labeled P1 on the left. 2. Match the connector on the previously installed motherboard with the pins on the motherboard you are installing. Slide the motherboard to the left until the pins are completely inserted in the connector of the previously installed motherboard. If you are installing the leftmost board, the pins will remain unconnected. 3. Secure the motherboard to the chassis with six torx screws. FigureTag FD9-222-02 The motherboard can be installed in any of the eight slots. If the bay has relay cards, they must be installed on the far right of the bay. P1 J1 Figure 4. Installing the Motherboard into a 4100 Expansion Bay 4. If you are installing the leftmost motherboard, connect a 733-525 Power and Communication Harness. Continue to the next topic to connect the harness. 8

Installing Motherboards into 2975-91xx Back Boxes (4100), Continued Connecting the 733-525 Harness If you need to connect a 733-525 Harness to a motherboard, refer to Figure 5 and follow these steps. Make sure to route the power and communication wiring on the left side of the bay. 1. Connect one end of the harness to a motherboard in an adjacent bay. If the adjacent bay is a master controller bay, connect the harness to the P2 and P3 connectors of the master controller motherboard and continue to step 2. If the adjacent bay is an expansion bay, connect the harness to the P2 and P3 connectors of the motherboard installed in the leftmost slot. (If a 4100-0155 SDACT or a 4100-0153 CCDACT occupies the leftmost slot, connect the harness to the motherboard in the second slot from the left.) Connect the harness as follows: a. Insert the harness connector with the blue wire into the P2 connector. Note that the P2 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. b. Insert the harness connector with the white wire into the P3 connector. Note that the P3 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. 9

Installing Motherboards into 2975-91xx Back Boxes (4100), Continued Connecting the 733-525 Harness (continued) 2. Connect the other end of the harness to the leftmost motherboard in the next bay, as described below. Make sure to route the wiring on the left side of the bay. a. Insert the harness connector with the blue wire into the P2 connector. Note that the P2 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. b. Insert the harness connector with the white wire into the P3 connector. Note that the P3 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. 733-659 Harness Connector with Blue Wire Goes to P2 Connector with White Wire Goes to P3 733-525 Harness 733-672 Harness Figure 5. Power and Communication Wiring for Motherboards 10

Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES) Overview The MAPNET transceiver modules can be mounted to either 4100 Back Boxes (PID series 2975-91xx) or 4100U/4100ES Back Boxes (PID series 2975-94xx). The 4120/4100-0110 and 4100-9802 versions are used with 4100 Back Boxes. The 4100-3102 and 4100-9812 versions are used with 4100U/4100ES Back Boxes. This section covers 4100-3102 and 4100-9812 module mounting into 2975-94xx Back Boxes. Installing into a 2975-94xx CPU Bay Up to two motherboards may be installed with the system CPU in the CPU bay. Use the following directions to mount a motherboard into a CPU bay. 1. Install the two nylon standoffs onto the threaded screws on the back side of the motherboard. 2. Orient the motherboard with the connector labeled J1 on the right and the header labeled P1 on the left. 3. Slide the motherboard to the right until the pins from P1 on the motherboard to the right are completely inserted in the motherboard s J1 connector. 4. Attach six lockwashers and metal standoffs to the chassis, and secure the motherboard to the chassis using six #6 screws. Slide the motherboard to the right until P1 on the first motherboard connects with J1 on the next one. J1 P1 CPU SPS Figure 6. Installing the Motherboard into a 4100U/4100ES CPU Bay 11

Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES), Continued Installing into a 2975-94xx Expansion Bay When installing 2 x 11 ½-inch motherboards in a 4100U/4100ES expansion bay, adhere to the following guidelines: Each expansion bay assembly includes a chassis, two end supports, one LED/switch frame, and a power distribution interface (PDI) board. An expansion bay holds up to eight 4 x 5 modules. A double-size module, such as the expansion power supply (XPS), takes up two blocks of space as shown below. Up to seven 2 x 11 ½ motherboards can be installed in an expansion bay if no 4 x 5 modules are installed in the bay. Motherboards are mounted on top of the PDI in expansion bays. The data and power that would normally be bussed via the PDI is instead routed across the boards via ribbon cable from one board to the next. As shown in the figure below, motherboards can be installed alongside 4 x 5 cards, if necessary. The leftmost slot must not contain a motherboard. 4 x 5 cards must be added from right to left. Motherboards must be added from left to right. FigureTag FD9-222-03 Slot 1 Slot 2 Slot 3 Slot 4 Position Block E 5 Position Block G 7 & 8 4100 Option 4100 Option 4100 Option I/O Wiring 4x5 Module I/O Wiring PDI Expansion Power Supply (XPS) No Boards Allowed in This Slot 4x5 Module I/O Wiring This slot cannot contain a motherboard. Position Block F 6 Block H Figure 7. Installing the Motherboard in a 4100U/4100ES Expansion Bay 12

Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES), Continued Installing into a 2975-94xx Expansion Bay (continued) Use the following procedure when installing motherboards in an expansion bay. Start with the second slot from the left and fill to the right. 1. Install the two nylon standoffs onto the threaded screws on the backside of the motherboard. 2. Orient the motherboard with the connector labeled J1 on the right and the header labeled P1 on the left. 3. Attach six metal threaded standoffs and lockwashers into the screw holes on the chassis. 4. Secure the motherboard to the standoffs using six #6 torx screws as shown in Figure 8. METAL STANDOFFS SCREW HOLES STANDOFFS #6 SCREWS SCREW HOLES LOCKWASHERS Figure 8. Installing the Motherboard in a 4100U/4100ES Expansion Bay 5. If you are installing the leftmost motherboard, connect a 733-525 Power and Communication Harness. Continue to the next topic to connect the harness. 13

Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES), Continued Connecting the 733-525 Harness If you need to connect a 733-525 Harness to a motherboard, refer to Figure 9 and follow these steps. Make sure to route the power and communication wiring on the left side of the bay. 1. Connect one end of the harness to a motherboard in an adjacent bay. If the adjacent bay is the CPU bay, connect the harness to the P8 and P7 connectors of the CPU motherboard. Insert the harness connector with the blue wire into the P8 connector. Note that the P8 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. Insert the harness connector with the white wire into the P7 connector. Note that the P7 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. If the adjacent bay is an expansion bay, connect the harness to the P2 and P3 connectors of the motherboard installed in the leftmost slot. (If an SDACT or CCDACT occupies the leftmost slot, connect the harness to the motherboard in the second slot from the left.) Connect the harness as follows: Insert the harness connector with the blue wire into the P2 connector. Note that the P2 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. Insert the harness connector with the white wire into the P3 connector. Note that the P3 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. 2. Connect the other end of the harness to the leftmost motherboard in the next bay, as described below. Make sure to route the wiring on the left side of the bay. Insert the harness connector with the blue wire into the P2 connector. Note that the P2 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. Insert the harness connector with the white wire into the P3 connector. Note that the P3 connector has eight pins. Insert the harness connector on either the top four pins or the bottom four pins, not in the middle. 14

Installing Motherboards into 2975-94xx Back Boxes (4100U/4100ES), Continued Connecting the 733-525 Harness (continued) 733-996 HARNESS 733-525 Harness Connector with Blue Wire Goes to P2 Connector with White Wire Goes to P3 Figure 9. Power and Communication Wiring for Motherboard 15

Installing the Daughter Card Installing the Daughter Card The daughter card inserts into the connector located in the center of the motherboard. The connector is keyed so that the daughter card fits only one way. Before installing the card, examine the slot in the motherboard and the fingers on the daughter card and note where the key is located. Note: The figure below is a general-purpose illustration that applies to all daughter cards. Figure 10. Installing the Daughter Card 16

Wiring the MAPNET Channel Overview This section contains field wiring guidelines and instructions for the MAPNET transceiver modules. General Guidelines Make sure these guidelines are accounted for before wiring: All wiring is supervised. MAPNET II communication power: 40 VDC @ 0.5 A, 3333 Baud. Refer to instructions packaged with each addressable device for its wiring connections. Any wiring leaving the building requires 2081-9044 Overvoltage Protectors where it leaves the building and another where it re-enters the building. Only four protectors total are allowed per MAPNET channel. Up to 43 Sounder Bases are allowed on a MAPNET channel, when used for coded operation. If Class A wiring is not used, the 733-678 Harness remains installed. Leave the 733-678 Harness on all unused loops. Up to 2 isolator boards per MAPNET channel are allowed. All wires must be 18 AWG, or as the local code dictates. Conductors must test free of all grounds. Wiring to IO terminals must not be run with AC wiring. Power must come from a Simplex-approved power supply. All wiring must be done using copper conductors only, unless noted otherwise. If shielded wire is used, - the metallic continuity of the shield must be maintained throughout the entire cable length. - the entire length of the cable must have a resistance greater than 1 Megohm to earth ground. Underground wiring must be free of all water. In areas of high lightning activity, or in areas that have large power surges, the 2081-9027 Transient Suppressor should be used on monitor points. Wires must not be run through elevator shafts. Wires that run in plenum must be in conduit. A system ground must be provided for earth detection and lightning protection devices. This connection must comply with approved earth detection per NFPA780. Only system wiring can be run together in the same conduit. 17

Wiring the MAPNET Channel, Continued Power-Limited Guidelines Make sure these guidelines are accounted for before wiring for power-limited systems: Non-power limited field wiring (AC power, batteries, City connection) must be installed and routed in the shaded areas shown in Figure 11. Power-limited field wiring must be installed and routed in the non-shaded areas shown in Figure 11, with the exception of City wiring. Excess slack should be kept to a minimum inside the back box enclosure. The wiring should be neatly dressed and bundled together using the wire ties provided with the equipment. Anchor power-limited wiring to tie points, as shown in Figure 11. CONDUIT ENTRANCE FOR POWER-LIMITED WIRING CONDUIT ENTRANCE FOR NON-POWER LIMITED WIRING NON-POWER LIMITED WIRING POWER-LIMITED WIRING TIE POINT (LOCATION MAY VARY) Figure 11. Power-Limited Wiring Tie the wiring located between bays to the internal wiring troughs, if applicable. When powering remote units or switching power through relay contacts, power for these circuits must be provided by a UPS-style power supply, the 4100-1108 Power Supply (8A), or a power-limited power supply that listed for fire-protective signaling use. 18

Wiring the MAPNET Channel, Continued Power-Limited Guidelines (continued) Auxiliary power only: In order to connect a circuit using power-limited wiring, the devices being powered must all be addressable, or a UL Listed EOL relay must be used to supervise the circuit. Refer to Figure 12 for wiring directions for the EOL relay. TO AUX POWER Note: The 2098-9739 Relay is used as an example. Other UL Listed EOL relays can be used, depending on the application. RED 2098-9739 END OF LINE RELAY BLACK YELLOW IDC LAST IDC DEVICE RESISTOR Figure 12. The EOL Relay 19

Wiring the MAPNET Channel, Continued Wiring Diagrams Refer to Figure 13 for examples of Class A and Class B wiring. The +, S, and - connection points are silkscreened on the board. If you are wiring a Class B MAPNET channel, connect a jumper between the two positive terminals and a jumper between the two minus terminals, as shown in the figure below. MAPNET LINE TO DEVICES TB1-7 (See Note 2) Class B Wiring PRIMARY MAPNET LINE TO DEVICES SECONDARY MAPNET LINE TO DEVICES Class A Wiring TB1 TB1 TB1-7 (See Note 2) TB1-3 (See Note 2) TB1-3 (See Note 2) Figure 13. Wiring MAPNET Channels Notes: 1. Wire length may not exceed 3,270 feet (1 km). 2. TB1-3 or TB1-7 are internally connected to Earth and are the normal termination point for MAPNET shields. Some audio systems may require MAPNET shields to be tied to System 0 V to minimize MAPNET cross-talk to speakers. 20

Signal and Power Connections Overview Proper operation of the MAPNET channel requires that you connect a 24 VDC power harness to pins 1, 2, and 3 of connector P4 on the MAPNET power supply for the 4100, or jumpering P3 to P4 for the 4100U/4100ES. The power requirements of the transceiver are as follows: 24 V Voltage Range: 20.4 to 32 VDC 24 V Current Draw: 25 ma, max. 8 V Voltage Range: 7.5 to 8.5 VDC 8 V Current Draw: 150 ma, max. Signal Voltage Range: Signal Current Draw: 20.4 to 32 VDC 200 ma @ 20.4 VDC (plus 1.75 ma per device, max.) 170 ma @ 24 VDC (plus 1.6 ma per device, max.) Pins 4 and 5 of P4, meanwhile, are used to connect to signal cards. Connect 24 V Power and Signal to P4 Figure 14. Location of P3 and P4 Connectors Non-4100U /4100ES Signal/Power Connections Figure 15, below, shows the power and signal connections for P4 when using the 4100. FigureTag FD9-222-04 POWER HARNESS (733-663) P4 ON 562-974 MAPNET POWER SUPPLY TO P17 ON UPS OR EXPANSION POWER SUPPLY 1 2 3 4 5 SIGNAL HARNESS (733-523) Figure 15. Signal and Power Connections (4100 only) TO P2, P3, OR P4 ON SIGNAL CARD OR P4 ON ADDITIONAL MAPNET TRANSCEIVER (if applicable) 21

Signal and Power Connections, Continued 4100U/4100ES Signal/Power Connections Figure 16, below, shows the power and signal connections when using the 4100U/4100ES. FigureTag FD9-222-05 8C* 8V* 24C* P3 ON 562-374 MAPNET POWER SUPPLY 1 2 3 4 5 6 7 POWER HARNESS (734-071) 1 2 3 1 2 3 3 Position Connector P4 ON 562-974 MAPNET POWER SUPPLY 1 2 3 4 5 6 24V* C* N/A* 24V* C* N/A* 24V* 8 4 4 Position Connector *Note: Designations are only shown as a reference. They do not appear on the PC board. Figure 16. Signal and Power Connections (4100U/4100ES only) 579-222 Rev. C