Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Similar documents
Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Phone: Fax: Web: -

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Manual Motor Starter MS 116. Technical Catalogue

Technical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB

Motor Controllers + Circuit Breakers

Technical Catalogue. Manual Motor Starters MS 116, MS 325, MS 4xx

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Short form catalogue Motor protection and control Manual motor starters

smissline Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Technical Catalogue Manual Motor Starters. MS 116, MS 325, MS 4xx

Miniature Circuit Breakers

KT4 Manual Motor Starter

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Control Circuit Protection

Technical data for manual motor starters Type MS325

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

System pro M compact Miniature Circuit Br eakers Description Features

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Product Specification Sheet #3LD2.1

Short-Circuit Current Ratings

Miniature Circuit Breaker UL / CSA Range

Ideal for use as a manual starter

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Manual Motor Starters. Meta-MEC

Bulletin 1489 Circuit Breakers. Selection Guide

A302DN.40/.63A Thermal Current Motor Starter

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Series L9 UL-489 Miniature Circuit Breakers

Tmax Molded Case Circuit Breakers

XT IEC Power Control Manual Motor Protectors

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Series L9 UL489 Miniature Circuit Breakers

Technical Information

Motor Starter Protectors

Tmax Molded Case Circuit Breakers

Motor Starter Protectors

US CATALOG. Miniature circuit breakers

New Dimension in Motor Protection Manual Motor Starter MS116

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Protection Equipment. 5/2 Introduction

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

US CATALOG. Miniature Circuit Breakers

C E R T I F I C A T E O F C O M P L I A N C E

Bulletin 140M Motor Protectors

Compact Circuit Protector

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Compact Circuit Protector

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Enclosures. See Section Typical Description

Short form catalogue. Motor protection & control

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

UMBW-UL489 and UL1077 Listed

1489-M Circuit Breakers

AF40... AF96 3-pole contactors Technical data

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

ACW Molded-Case Circuit Breaker UL 489 Listed

Self-protected Combination Starters System PKZ 2-SP

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Softstarters Type PSS. Softstarters. General information

SECTION MOTOR CONTROL

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

j~åì~ä=jçíçê=pí~êíéêë=~åç jçíçê=pí~êíéê=`çãäáå~íáçåë 7.5 kw) Economic solution up to 7.5 kw thanks to small fuseless protection = =

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

3. Coils shall be of molded construction

4 - Miniature controls

Bulletin 190-M Compact Starters. Selection Guide

MS General Information Extended Product Type: MS

AF series contactors (9 2650)

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Description. Positive safety relays

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

AF series contactors (9 2650)

FMotor Circuit Controllers

Protection Equipment

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

C E R T I F I C A T E O F C O M P L I A N C E

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Selection Guide Motor Control Device Solutions

KT4 Manual Motor Starters

Transcription:

Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified for Group Motor Installations 12 Setting ranges from 0.1 to 16 amps. Up to 30kA or 0kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS32 Suitable for use with 3-phase motors up to 1 HP @ 480V UL Listed and CSA certified for Group Motor Installations 12 Setting ranges from 0.1 to 2 amps. Up to 0kA or 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS4x Suitable for use with 3-phase motors up to 40 HP @ 480V UL Listed and CSA certified for Group Motor Installations 14 Setting ranges from 11 to 0 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS49x Suitable for use with 3-phase motors up to 7 HP @ 480V UL Listed and CSA certified for Group Motor Installations 22 Setting ranges from 11 to 100 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Single motor applications Single motor applications employing a manual motor protector (MMP) result in a simple, compact and economical alternative to conventional magnetic motor controllers for manual operation of a single motor. Upstream short circuit and overcurrent protection in the form of fuses or a circuit breaker is required but the MMP can replace the overload relay, contactor and associated electrical components and wiring for controlling the contactor. Group motor applications Group motor installations offer several advantages when controlling two or more motors or other loads over conventional single motor starters. Several MMPs can be grouped together and fed from a single set of fuses or a circuit breaker. These devices can be installed together on a single DIN rail and fed power through three phase insulated busbars and a power feed terminal. Protecting this group of MMPs is a single circuit breaker or fusible switch, sized specifically for the load. Excellent coordination and short circuit protection can be achieved, as high as 0kAIC, when using the MS32 product in this manner. Close coupling adapters are offered to connect contactors to the load side of each MMP for automatic operation of each motor. If a single motor experiences an overload, the associated MMP trips and allows the other motors to continue running. Numerous accessories are available for signaling in the event of a trip, to indicate status, to provide shunt trip and for undervoltage release. The main benefits of group installation are quick, fool proof assembly, minimal wiring and a reduction of the necessary enclosure size. The only constraint is that the upstream circuit protective device must be sized specifically for the load a highly desirable feature in order to provide the closest coordination and the greatest level of circuit protection. Article 430.3(C) of the NEC specifies the requirements for group motor installations; all ABB MMPs meet these requirements.

Manual motor protectors General information Selection Group installation is an approach to building multi-motor control systems in accordance with Section 430-3 of the National Electrical Code. The selection of components used in group installations is a simple process which consists of several steps. First is the selection of the appropriate fuse as Branch Circuit Protective Device (BCPD). Second is the selection of the appropriate motor starter and protector. Third, the selected MMP must be checked for UL listing with the selected BCPD and the available short circuit current at the application location. 1. Fused disconnect Calculate maximum fuse size according to NEC 430-3 (c). I max (fuse size) = 17% x FLC (full load current for largest motor) + the sum of FLC (full load current for largest motor) + the sum of FLC values for other motors on that branch using NEC Table 430-10 on the right. Select fuse from NEC Table 240-6 below. Where I max falls between two fuse ampere ratings NEC 430-3 (c) permits going to the next high ampere rating. 2. Motor protector selection Select the proper MMP catalog number for each motor load from the following pages based on the actual motor full load current (FLA) using the Thermal setting range column for reference. 3. MMP Interruption ratings Using the interruption ratings table on the next page, identify the system application voltage and interrupting capacity for the type of fuse selected in step 1 above. NEC 240-6 Standard fuse amperes 1, 20, 2, 30, 40, 4, 0, 60, 70, 80, 90, 110, 12, 10, 17, 200, 22, 20, 300, 30, 400, 40, 00, 600, 700, 800, 1000, 1200, 1600 Examples: Select components for protecting the following 3-phase, 460VAC, squirrel cage induction motors. The nameplate data are: 1/2 HP, 1.0 FLA; 3 HP, 4.8 FLA; HP, 7.6 FLA; 7. HP, 11 FLA; 10 HP, 14 FLA. Example: using fused disconnect I max = 17% x 14 + (11 + 7.6 + 4.8 + 1) = 48.9A Fuse rating using Table NEC 240-6 = 0A Minimum disconnect size = 11% x Total FLA NEC 430-10 table = 11% x (14+ 11 + 7.6 + 4.8 + 1) = 44.16 Disconnect for 0A fuses is ok. Note: Refer to NEC 310-1 and NEC 430-3(d) for cable sizing. NEC Table 430-10 full load current, 3ph AC motor Horsepower Induction type squirrel cage & wound rotor 1 230V 460V 7V amps amps amps 1/2 2 1.8 3/4 2.8 1.4 1.1 1 3.6 1.8 1.4 1..2 2.6 2.1 2 6.8 3.4 2.7 3 9.6 4.8 3.9 1.2 7.6 6.1 7. 22 11 9 10 28 14 11 1 42 21 17 20 4 27 22 2 68 34 27 For full load currents of 208 and 200 volt motors, increase the corresponding 230 volt motor full-load current by 10% and 1%, respectively. MS32 data Horsepower Motor rating at 460V FLA, AC3 MS32 1/2 1.0 MS32-1.0 A9C 3 4.8 MS32-6.3 A9C 7.6 MS32-9.0 A9C 7. 11 MS32-12. A12C 10 14 MS32-16 A16C Contactor INCOMING LINES A B C ISOMAX MCCB or Fusible Switch (If specified) 1 3 1 3 1 3 1 3 1 3 I> I> I> 2 4 6 1M I> I> I> 2 4 6 2M I> I> I> 2 4 6 3M I> I> I> 2 4 6 4M I> I> I> 2 4 6 M L1 L2 L3 1C L1 L2 L3 2C L1 L2 L3 3C L1 L2 L3 4C L1 L2 L3 C T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 MOTOR MOTOR MOTOR MOTOR MOTOR 1 These values of full-load current are for motors running at speeds usual for belted motors and motors with normal torque characteristics. Motors built for especially low speeds or high torques may require more running current, and multispeed motors will have full-load current varying with speed, in which case the nameplate current rating shall be used. The voltage listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 110 to 120, 220 to 240, 440 to 480, and 0 to 600 volts.

Type MS116 Manual motor protectors MS116 Manual motor protectors Thermal setting Single-phase 3-phase Catalog List range (Amps) horsepower ratings 1 horsepower ratings number price 120V 240V 240V 480V 600V MS116 0.10 0.16 MS116-0.16 0.16 0.2 MS116-0.2 $ 129 0.2 0.40 MS116-0.40 0.40 0.63 MS116-0.63 0.63 1.0 1/2 1/2 MS116-1.0 1.0 1.6 1/10 3/4 3/4 MS116-1.6 1.6 2. 1/6 1/2 1 1. MS116-2. 148.0 2. 4.0 1/8 1/3 1 2 3 MS116-4.0 4.0 6.3 1/4 1/2 1. 3 MS116-6.3 6.3 10 1/2 1. 3 7. MS116-10 8.0 12 1/2 2 3 7. 10 MS116-12 172.0 10.0 16 1 2 10 10 MS116-16 UL File # E137861 Short circuit rating of 18kA @ 480VAC Class 10 overload Accessories, UL File # E9037 1 Single phase motor ratings are based upon wiring all three poles in series. Phone: 800.894.0412 - Fax: 888.723.4773 Discount - Web: schedule www.clrwtr.com MA [OM] - Email: info@clrwtr.com

Manual motor protectors Type MS116 Accessories Auxiliary contact blocks for Type MS116 (right side mount) Contact Catalog List configuration number price 1 NO & 1 NC HK1-11 2 NO HK1-20 $ 33 2 NC HK1-02 Auxiliary contact blocks for Type MS116 (front mount) Contact Catalog List configuration number price 1 NO & 1 NC HKF1-11 $ 33 HK1-11 HKF1-11 Bell alarm contact blocks for Type MS116 (right side mount) Contact Catalog List configuration number price Undervoltage trip for Type MS116 (left side mount) 1 NO & 1 NC SK1-11 2 NO SK1-20 $ 33 2 NC SK1-02 Voltage (VAC) Catalog number List price 24 UA1-24 48 UA1-48 60 UA1-60 120 UA1-120 $ 82.0 230 UA1-230 400 UA1-400 41 UA1-41 SK1-11 UA1-120 Shunt trip for Type MS116 (left side mount) Voltage Catalog List (VAC) number price 24V AA1-24 110V AA1-110 200 240V AA1-230 30 41V AA1-400 $ 7 MS32-SA1 MS32-SA3 Locking device for Type MS116 Description Catalog number Adaptor for padlock Type SA1 MS32-SA1 $ 1 Complete padlock locking kit (adaptor, padlock & 3 keys) MS32-SA3 37.0 Molded plastic enclosures for Type MS116 Plastic adaptors for enclosures for Type MS116 Description Catalog number List price Item Protection Catalog List description level number price Gray enclosure with black handle IP6 IB116-G 7 Yellow enclosure with red handle IP6 IB116-Y 7 List price PG16 to 1/2NPT PG16-1/2NPT $ 10 IB116-G

Type MS116 Accessories Manual motor protectors OHB2AJ Door mounting hardware for for Type MS116 1 Description Power feed terminal blocks for Type MS116 Description Flush w/bus bar Extends over busbar S1-M1 S1-M2 Catalog number Catalog number List price Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 Black selector handle 1SCA022384R6940 30 NEMA 1, 3R, 12 Red, yellow selector handle 1SCA022384R7080 30 4.1 length shaft 1SCA022347R360 4 7.1 length shaft 1SCA02233R4620 6 List price $ 24 S1-M1 PS1-2-1 S1-M2 Busbars for Type MS116 (63A max.) Description Catalog number List price for 2 devices without auxiliary contacts PS1-2-0 $ 24 for 3 devices without auxiliary contacts PS1-3-0 30 for 4 devices without auxiliary contacts PS1-4-0 36 for devices without auxiliary contacts PS1--0 42 for 2 devices with 1 auxiliary contact PS1-2-1 24 for 3 devices with 1 auxiliary contact PS1-3-1 30 for 4 devices with 1 auxiliary contact PS1-4-1 36 for devices with 1 auxiliary contact PS1--1 42 for 2 devices with 2 auxiliary contacts PS1-2-2 24 for 3 devices with 2 auxiliary contacts PS1-3-2 30 for 4 devices with 2 auxiliary contacts PS1-4-2 36 for devices with 2 auxiliary contacts PS1--2 42 Busbar cover BS3-3 9 Busbar/Close coupling adapter for direct mounting of contactors Description Catalog number List price B6/B7 BEA7/116 $ 12 A9/A12/A16 BEA16/116 13.0 A26 BEA26/116 1 AL9 - AL16 BEA16/116AL 13.0 PS1-... S1- M1 S1- M2 PS1-... BS3-3 SK1-... HK1-... SA1 HKF1-11 1 Must have shaft coupler, handle and shaft for through-the-door operation. 2 Consult factory. HK1-... HK1-...

Manual motor protectors Type MS116 Technical data Softstarter type MS116 Standards, approvals UL, CSA, CE Rated operating current A 16 Current range A 0.16 16 Number of poles 3 Frequency Hz 0 / 60 Tripping class A 10 Max. kaic & 600V kaic 30 Mechanical life Operations 100,000 Wire range AWG 12 18 Terminal torque in. lbs. 14 Terminal tool options Flat screwdriver PZ2 Permissible attitude without derating m 3000 Degree of protection IP20 UL Listed for group installation Yes Self-protected Type E manual combination starter No Accessories Terminal shroud No Auxiliary contacts Yes Shunt trip No Trip signal contacts Yes UV release Yes Busbar Yes Through the door handle Yes Minimum enclosure size H x W x D Loads for accessories Auxiliary contact for front mounting, HKF AC1 24 V, 3.0 A 230 V, 1. A Auxiliary contact for front mounting, HKF DC13 24 V, 1.0 A 48 / 60V, 0.7 A 110 V, 0.27 A Auxiliary and signal contact, HK + SK AC1 24 V, 6 A 230 V, 4 A 400 V, 3 A Auxiliary and signal contact, HK + SK DC13 24 V, 2 A 110 V, 0. A 220 V, 0.2 A 440 V, 0.1 A Electromagnet trips Response value set ex-works 9.6 14.4 x In Undervoltage release Pick-up value % of U C 8 Drop-out value % of U C 3 7 Power consumption Pick-up VA Consult factory Hold VA Consult factory

Type MS116 Technical data Manual motor protectors General purpose MS116 range Short circuit ratings (UL & CSA) 18,000 RMS symmetrical 480 VAC,000 RMS symmetrical 600 VAC Maximum current (600 VAC Max.) 0.1 0.16 0.16 0.16 0.2 0.2 0.2 0.40 0.40 0.04 0.63 0.63 0.63 1.0 1.0 1.0 1.6 1.6 1.6 2. 2. 2. 4.0 4.0 4 6.3 6.3 6.3 10 10 8 12 12 10 16 16 Maximum ratings Horsepower, HP, Breaking-All-Lines MS116 Single phase Three phase Range 0/60 Hz 0/60 Hz 120 VAC 240 VAC 240 VAC 480 VAC 600 VAC 0.1 0.16 0.16 0.2 0.2 0.40 0.40 0.63 0.63 1.0 1/2 1/2 1.0 1.6 1/10 3/4 3/4 1.6 2. 1/6 1/2 1 1 1/2 2. 4.0 1/8 1/3 1 2 3 4.0 6.3 1/4 1/2 1 1/2 3 6.3 10 1/2 1 1/2 3 7 1/2 8 12 1/2 2 3 7 1/2 10 10 16 1 2 10 10 MS116 Short circuit ratings for group installations Short circuit ratings at 480 VAC Maximum breaker or fuse size MS16 ka 18 ka 30 ka 0kA Current Range Fuse MCCB Fuse MCCB Fuse MCCB Fuse MCCB 0.1-0.2 1200 S7H1200 - - - - 0.2-0.3 1200 S7H1200 - - - - 0.3-0.4 1200 S7H1200 - - - - 0.4-0.6 1200 S7H1200 - - - - 0.6-1.0 1200 S7H1200 - - - - 1.0-1.6 1200 S7H1200 - - - - 1.6-2. 1200 S7H1200 - - - - 2. - 4.0 1200 S7H1200 - - - - - - 4.0-6.3 1200 S7H1200 - - - - 6.3-10.0 1200 S7H1200 - - - - 8.0-12.0 1200 S7H1200 - - - - 10-16 - - - - - - - - Fuse: Rated 1200 A, Listed Class L. All others, Listed K. Both Time-delay fuses. Circuit breaker: Listed ABB Short circuit ratings at 600 VAC Maximum breaker or fuse size MS116 ka 10 ka 18kA Current Range Fuse MCCB Fuse MCCB Fuse MCCB 0.1-0.2 1200 S7H1200 0.2-0.3 1200 S7H1200 0.3-0.4 1200 S7H1200 0.4-0.6 1200 S7H1200 0.6-1.0 1200 S7H1200 1.0-1.6 1200 S7H1200 1.6-2. 1200 S7H1200 2. - 4.0 - - - - - - 4.0-6.3 1200 S7H1200 - - 6.3-10.0 1200 S7H1200 - - 8.0-12.0 1200 S7H1200 - - - - 10-16 - - - - - - Fuse: Rated 1200 A, Listed Class L. All others, Listed K. Both Time-delay fuses. Circuit breaker: Listed ABB

Manual motor protectors Type MS116 Approximate dimensions MS116 MS116 mounted with A9 - A16 contactor MS116 mounted with B6/B7 minicontactor 4 8,6 8.6 4 8.6 177 HKF1-11 19 HKF1-11 BEA16/116E BEA7/116 A9... A16 B6 / B7 47. 47 7 2 MS116 mounted with UA1..., SK1..., HK1..., HKF1-11 18 9 9 UA1-... SK1-... HK1-... 90 HKF1-11 81 8.6

Type MS116 Approximate dimensions Manual motor protectors IB116 Y/G

Manual motor protectors Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number price (Amps) 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16 0.16 0.2 MS32-0.2 $ 144 0.2 0.40 MS32-0.40 0.40 0.63 MS32-0.63 0.63 1.0 1/2 1/2 MS32-1.0 1.0 1.6 1/10 3/4 3/4 MS32-1.6 1.6 2. 1/6 1/2 1 1. MS32-2. 16 2. 4.0 1/8 1/3 1 2 3 MS32-4.0 4.0 6.3 1/4 1/2 1. 3 MS32-6.3 6.3 9.0 1/3 1 2. 7. MS32-9.0 9.0 12. 1/2 2 3 7. 10 MS32-12. 192 12. 16 1 2. 10 10 MS32-16 16 20 1. 3 10 1 MS32-20 211.0 20 2 2 3 7. 1 20 MS32-2 223.0 MS32 UL File #E137861 Accessories UL File #E9033 Single phase motor ratings are based upon wiring all three poles in series.

Manual motor protectors Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number 2 price (Amps) 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16E 0.16 0.2 MS32-0.2E $ 223 0.2 0.40 MS32-0.40E 0.40 0.63 MS32-0.63E 0.63 1.0 1/2 1/2 MS32-1.0E 1.0 1.6 1/10 3/4 3/4 MS32-1.6E 1.6 2. 1/6 1/2 1 1. MS32-2.E 244 2. 4.0 1/8 1/3 1 2 3 MS32-4.0E 4.0 6.3 1/4 1/2 1. 3 MS32-6.3E 6.3 9.0 1/3 1 2. 7. MS32-9.0E 9.0 12. 1/2 2 3 7. 10 MS32-12.E 271 12. 16 1 2. 10 10 MS32-16E 16 20 1. 3 10 1 MS32-20E 290 20 2 2 3 7. 1 20 MS32-2E 302 MS32 UL File #E137861 Accessories UL File #E9033 Class 10 overload Short circuit rating of 18kA @ 480V 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Part includes MMP, barrier and trip signal.

Manual motor protectors Type MS32 Accessories MS32-HK11 Auxiliary contact blocks for Type MS32 (left side mount), 2 max. Auxiliary contact blocks for Type MS32 (front mount) 1 NO & 1 NC MS32-HK11 2 NO MS32-HK20 $ 33 2 NC MS32-HK02 1 NO & 1 NC MS32-HKF11 2 NO MS32-HKF20 $ 33 Bell alarm contact blocks for Type MS32 (left side mount) 1 1 NO MS32-SK10 1 NC MS32-SK01 $ 33 MS32-HKF11 Shunt trips for Type MS32 110 240 VAC/VDC, 60 Hz MS32-ST110 24 60 VAC/DC, 60 Hz MS32-ST24 $ 82.0 MS32-UA24 Undervoltage trip for Type MS32 (slide - internal) 24V MS32-UA24 48V MS32-UA48 60V MS32-UA60 110V MS32-UA110 $ 82.0 230V MS32-UA230 400V MS32-UA400 41V MS32-UA41 480V MS32-UA480 MS32-AS Supporting terminal for Type MS32 for UA or as N/LS clamp MS32-AS $ 1 Padlocking devices for Type MS32 Adapter for padlock type SA1 MS32-SA1 $ 1 Complete padlock kit (includes adaptor, padlock & 3 keys) MS32-SA3 37.0 MS32-SA1 MS32-SA3 1 Only changes state in the event of a trip. Phone: 800.894.0412 - Fax: 888.723.4773 Discount schedule - Web: MA www.clrwtr.com [OM] - Email: info@clrwtr.com

Type MS32 Accessories Manual motor protectors IB32-G Switch cublicle mounting kit Molded plastic enclosures for Type MS32 Selector handles for through-the-door operation for Type MS32 1 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle 1SCA022384R6940 30 NEMA 1, 3R, 12 red/yellow selector handle 1SCA022384R7080 30 4.1 length shaft 1SCA022347R360 4 7.1 length shaft 1SCA02233R4620 6 NOTE: Use Discount schedule MA [OM] for shaft coupler; use Discount schedule H6 [DH] for handles and shafts. Power feed terminal blocks for Type MS32 Item Protection Catalog List description level number price Gray enclosure with black handle IP6 IB32-G $ 7 Yellow enclosure with red handle IP6 IB32-Y 7 NOTE: Use Discount schedule MA [OM] for IP64 & IP6 enclosures; use Discount schedule CB21 [BZ] for IP enclosures. Not suitable for Type E. Plastic adaptors for enclosures for Type MS32 PG16 TO 1/2 NPT PG16-1/2 NPT $ 10 Standard, accepts 4 AWG wire flush w/busbar MS32-SM1 $ 24 Low profile, accepts 4 AWG wire external over busbar MS32-BB1 2.0 MS32-BB1 MS32-SM1 PS3-2-0 PS3-4-0 Busbars for Type MS32 2 for 2 devices; without auxiliary switch PS3-2-0 $ 24 for 3 devices; without auxiliary switch PS3-3-0 30 for 4 devices; without auxiliary switch PS3-4-0 33 for devices; without auxiliary switch PS3--0 39 for 2 devices; with 1 auxiliary switch PS3-2-1 30 for 3 devices; with 1 auxiliary switch PS3-3-1 34.0 for 4 devices; with 1 auxiliary switch PS3-4-1 37.0 for devices; with 1 auxiliary switch PS3--1 42 for 2 devices; with 2 auxiliary switches PS3-2-2 30 for 4 devices, with 2 auxiliary switches PS3-4-2 37.0 Busbars can be daisy chained to connect additional MS32s. Close coupling adapters Busbar cover BS3-3 9 Device MS32 + B6/B7 contactor MS32 + VB6/VB7 reversing contactor Catalog number BEA7/32 MS32-VB7 List price MS32 + A9, A12, A16 contactor BEA16/32 13.0 MS32 + A26 contactor BEA26/32 1 AL9 - AL16 BEA16/32AL 13.0 AL26 BEA26/32AL 1 $ 12 UL 08 Type E Accessories Required Device Catalog number List price Line side infeed block S3-M3 $ 30 Short circuit trip signal CK-11 49 MS32 coupled to mini-contactor 1 Must have shaft coupler, handle and shaft for through-the-door operation. 2 UL file # E16720; CSA file# LR98427M7-11. 3 Consult factory.

Manual motor protectors Type MS40 MS497 MS40 MS497 Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Horsepower ratings Three-phase 11V 230V 200V 208V 230V 460V 7V Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time UL File # E16720 Weight Availability Catalog List (lbs) code number price MS40 11 16 1 3 10 1 2.12 A MS40-16 $ 40 14 20 1. 3 7. 1 20 2.12 A MS40-20 40 18 2 2 7. 10 20 2 2.12 A MS40-2 40 22 32 3 10 10 2 30 2.12 A MS40-32 40 28 40 3 7. 1 1 30 40 2.12 A MS40-40 10 36 4 7. 1 1 30 40 2.12 A MS40-4 10 40 0 10 1 20 40 0 2.12 A MS40-0 10 MS49 28 40 3 7. 1 1 30 40 4.63 A MS49-40 62.0 36 0 10 1 20 40 0 4.63 A MS49-0 62.0 4 63 1 20 2 0 60 4.63 A MS49-63 62.0 7 7 7. 1 2 2 60 7 4.63 A MS49-7 600 70 90 10 20 30 30 7 100 4.63 A MS49-90 61 80 100 10 2 40 40 7 100 4.63 A MS49-100 690 MS497 11 16 1 3 10 1 2.12 B MS497-16 40 14 20 1. 3 7. 1 20 2.12 B MS497-20 40 18 2 2 7. 10 20 2 2.12 B MS497-2 40 22 32 3 10 10 2 30 2.12 B MS497-32 40 28 40 3 7. 1 1 30 40 4.63 B MS497-40 62.0 36 0 10 1 20 40 0 4.63 B MS497-0 62.0 4 63 20 2 0 60 4.63 B MS497-63 62.0 7 7 7. 2 2 60 7 4.63 B MS497-7 600 70 90 10 30 30 7 100 4.63 B MS497-90 61 80 100 10 30 40 7 100 4.63 B MS497-100 690 MS41 11 16 1 3 10 1 2.12 B MS41-16 40 14 20 1. 3 7. 1 20 2.12 B MS41-20 40 18 2 2 7. 10 20 2 2.12 B MS41-2 40 22 32 3 10 10 2 30 2.12 B MS41-32 40 28 40 3 7. 1 1 30 40 2.12 B MS41-40 10 36 4 7. 1 1 30 40 2.12 B MS41-4 10 40 0 10 1 20 40 0 2.12 B MS41-0 10 MS496 28 40 3 7. 1 1 30 40 4.63 B MS496-40 62.0 36 0 10 1 20 40 0 4.63 B MS496-0 62.0 4 63 1 20 2 0 60 4.63 B MS496-63 62.0 7 7 7. 1 2 2 60 7 4.63 B MS496-7 600 70 90 10 20 30 30 7 100 4.63 B MS496-90 61 80 1002 10 2 40 40 7 100 4.63 B MS496-100 690 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. Phone: 800.894.0412 - Fax: 888.723.4773 Discount schedule - Web: MA [OM] www.clrwtr.com - Email: info@clrwtr.com

Type MS40 MS497 for UL 08 Type E Applications Manual motor protectors MS40-16E MS497-16E Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time Horsepower ratings Three-phase 11V 230V 200V 208V 230V 460V 7V Weight Availability Catalog 3 List (lbs) code number price MS40 11 16 1 3 10 1 2.12 A MS40-16E $ 2 14 20 1. 3 7. 1 20 2.12 A MS40-20E 2 18 2 2 7. 10 20 2 2.12 A MS40-2E 2 22 32 3 10 10 2 30 2.12 A MS40-32E 2 28 40 3 7. 1 1 30 40 2.12 A MS40-40E 8 36 4 7. 1 1 30 40 2.12 A MS40-4E 8 40 0 10 1 20 40 0 2.12 A MS40-0E 8 MS49 28 40 3 7. 1 1 30 40 4.63 A MS49-40E 622.0 36 0 10 1 20 40 0 4.63 A MS49-0E 622.0 4 63 1 20 2 0 60 4.63 A MS49-63E 622.0 7 7 7. 1 2 2 60 7 4.63 A MS49-7E 720 70 90 10 20 30 30 7 100 4.63 A MS49-90E 73 80 100 10 2 40 40 7 100 4.63 A MS49-100E 810 MS497 11 16 1 3 10 1 2.12 B MS497-16E 70 14 20 1. 3 7. 1 20 2.12 B MS497-20E 70 18 2 2 7. 10 20 2 2.12 B MS497-2E 70 22 32 3 10 10 2 30 2.12 B MS497-32E 70 28 40 3 7. 1 1 30 40 4.63 B MS497-40E 622.0 36 0 10 1 20 40 0 4.63 B MS497-0E 623 4 63 20 2 0 60 4.63 B MS497-63E 622.0 7 7 7. 2 2 60 7 4.63 B MS497-7E 720 70 90 10 30 30 7 100 4.63 B MS497-90E 73 80 100 10 30 40 7 100 4.63 B MS497-100E 810 MS41 11 16 1 3 10 1 2.12 B MS41-16E 2 14 20 1. 3 7. 1 20 2.12 B MS41-20E 2 18 2 2 7. 10 20 2 2.12 B MS41-2E 2 22 32 3 10 10 2 30 2.12 B MS41-32E 2 28 40 3 7. 1 1 30 40 2.12 B MS41-40E 8 36 4 7. 1 1 30 40 2.12 B MS41-4E 8 40 0 10 1 20 40 0 2.12 B MS41-0E 8 MS496 28 40 3 7. 1 1 30 40 4.63 B MS496-40E 623 36 0 10 1 20 40 0 4.63 B MS496-0E 720 4 63 1 20 2 0 60 4.63 B MS496-63E 720 7 7 7. 1 2 2 60 7 4.63 B MS496-7E 720 70 90 10 20 30 30 7 100 4.63 B MS496-90E 73 80 1002 10 2 40 40 7 100 4.63 B MS496-100E 810 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. 3 Catalog number includes all parts required for UL08/E applications. Phone: 800.894.0412 - Fax: 888.723.4773 Discount - Web: schedule www.clrwtr.com MA [OM] - Email: info@clrwtr.com

Manual motor protectors HK4-11 Auxiliary contacts top mount Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price 1 N.O. + 1 N.C..044 10 A HK4-11 1 changeover.044 10 B HK-W Auxiliary contacts mounts on left side, max. 1 Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price 1 N.O. + 1 N.C..066 2 A HKS4-11 2 N.O..066 2 B HKS4-20 $ 36 2 N.C..066 2 B HKS4-02 Auxiliary release Only one auxiliary release per manual motor protector Mounts on right side of manual motor protector $ 36 UA4-HK-220 AA4-24 Item Rating Weight Pkg. Avail. Catalog List description (lbs) qty. code number price 24V, 0--60 Hz.264 1 A UA4-24 110 120V, 0 60Hz.264 1 A UA4-120 Undervoltage release 230 240V, 0 60Hz.264 1 A UA4-240 400V, 0Hz.264 1 B UA4-400 Shunt trip Voltage Voltage continuous sec. max. 0 60Hz 0 60Hz, DC Power feed terminal blocks for MS4X 20 24 20 70V.242 1 B AA4-24 30 110 70 190V.242 1 A AA4-110 210 240 190 330V.242 1 B AA4-240 30 41 330 00V.242 1 B AA4-41 $ 93 For feeding power to multiple MS4Xs when using busbar Accepts 10-1/0 AWG, 108A Busbars for MS4X (108A max.) 93 S4-M1 $ 81 PS4-2-0 $ 1 Without side mounted auxiliary devices PS4-3-0 60 PS4-4-0 76.0 PS4-2-2 8.0 With one side mounted auxiliary device PS4-3-2 60 PS4-4-2 84 Busbar cover BS4-3 9 Close coupling adapters MS4X + A30, A40 BEA40/40 $ 4 MS4X + A0 BEA0/40 63 MS49X + A0, A63, A7 BEA7/49 120 MS49 + A9, A110 BEA110/49 180 1 Mounting sequence: motor protection switch, pilot switch, auxiliary switch.

Type MS40 MS497 Accessories Manual motor protectors Terminal shrouds Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price for MS4x.022 1 A KA40 1 $ 1 for MX49x.022 1 A KA49 1 18 for MS49x.066 1 A KA49C 2 21 Type E Terminal Required for UL 08 Type E Applications Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price for MS49x.0 1 B DX49 $ 4 KA40 Signalling contact indication of short-circuit trip (required for UL08 Type E applications) Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price Short circuit trip 1 N.O. + 1 N.C..14 1 A SK4-11 $ 60 MS4x / MS49x DX49 Selector handles for thru the door operation for Types MS40 & MS41 4 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 7 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ 7 4.1 length shaft OXSX10 4 7.1 length shaft OXSX180 7 SK4-11 1 Plug onto box terminals in each case. 2 Plug onto housing after removing box terminals, if using cable lugs or buses. 3 Supplied only as a set of 10 scale covers. 4 Must have shaft coupler, handle and shaft for through-the-door operation. Not required for MS4x. 6 MS49x Series are not suitable for thru-the-door operation. 7 Consult factory. Discount schedule MA [OM] Manual motor protectors Discount schedule H6 [DH] Handles, shafts & accessories

Manual motor protectors Technical data Type MS32, MS4x, MS49x Device type MS32 MS40 MS41 MS49 MS496 MS497 Standards, approvals UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE Rated operating current A 2 0 0 100 100 100 Current range A 0.10-2 11-0 11-0 40-100 28-100 11-100 Number of poles 3 3 3 3 3 3 Frequency Hz 0/60 0/60 0/60 0/60 0/60 0/60 Tripping class A 10 10 20 10 20 10 Max. kaic & 600V kaic 0 0 0 0 100 100 Mechanical life Operations 100,000 0,000 0,000 0,000 0,000 0,000 Wire range AWG 14-8 1x18-2; 2x18-3 1x18-2; 2x18-3 2x10-1/0; 1x10-2/0 2x10-1/0;1x10-2/0 2x10-1/0; 1x10-2/0 Terminal torque in. lbs 14 27 40 27 40 3 3 3 3 3 3 Terminal tool options flat screwdriver flat screwdriver flat screwdriver hex allen hex allen hex allen PZ2 PZ2 PZ2 4mm 4mm 4mm Permissible altitude without derating m 3000 2000 2000 2000 2000 2000 Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 UL Listed for group installation Yes Yes Yes Yes Yes Yes Self-protected Type E manual combination starter Yes Yes Yes Yes Yes Yes Accessories Terminal shroud No Yes Yes Yes Yes Yes Auxiliary contacts Yes Yes Yes Yes Yes Yes Shunt trip Yes Yes Yes Yes Yes Yes Trip signal contacts Yes Yes Yes Yes Yes Yes UV release Yes Yes Yes Yes Yes Yes Busbar Yes Yes Yes No No No Through door handle Yes Yes Yes No No No

Technical data Type MS32, MS4x, MS49x Manual motor protectors Manual motor starter type MS32 MS40/41 MS49/496/497 Auxiliary circuits Load rating of the auxiliary circuits Minimum load at: 24 VDC ma ma at 17 VDC 12 VDC ma 10 Rated operating at AC 1 to 24 VAC A 2. current I e 230 VAC A 2 3 / 0. / 6 400 VAC A 1 1. / / 3 12 Rated operating at DC 13 to 24 VDC A 2. / / current I e 60 VDC A 2. / 0.1 / 110 VDC A 0.6 0.22 / / 0. 220 VDC A 0.2 0.1 / / 0.2 440 VDC A / 0.1 Short circuit protection back up fuse gl A 10 gl / gg 10 A am A 6 Release Device for phase failure protection With With Electromagnetic trips Response value set ex-works 7. 12 I n (.16 -.63)A 10.4 I n 1.6 I n 9 14 I n (1-2.)A 10 1 I n (4-6.3)A 12. 17. I n (9-2)A Undervoltage release Pick-up value % of U c 8 8 Drop-out value % of U c 3 7 3 70 Power consumption - Pick-up VA 0.9 20.2 Power consumption - Hold VA 0.9 7.2 Open circuit shunt release Pick-up value % of U c 8 70 Relative duty consumption % ED 100 at voltages 0 / 60 Hz to Power Pick-up VA 110-240V: 13-61 3 Consult factory Hold VA Consult factory 1 Correction factors for other frequencies on request. 2 On front side 1 chageover contact / on front side 1 NO + 1 NC / at side, 1 NO + 1 NC, 2 NO, 2 NC 3 24-60V: 14.4-90vA

Manual motor protectors Technical data Type MS32 Short circuit ratings Short circuit ratings MS32 Group installation short circuit ratings Up to 480V 1 MS32 ka 30 ka 0 ka 8kA Current Fuse MCCB Fuse MCCB Fuse MCCB Fuse range A A A A 0.1-0.16 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.2-0.40 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.40-0.63 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.63-1.0 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 1.0-1.6 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 1.6-2. 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 2. - 4.0 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 4.0-6.3 1600 S7H1200 1600 S7H1200 600 S7H1200 6.3-9.0 1600 S7H1200 1600 S7H1200 600 S7H1200 9.0-12. 1600 S7H1200 1600 S7H1200 400 S4H20 12. - 16 1600 S7H1200 1600 S7H1200 400 S4H20 16-20 1600 S7H1200 1600 S7H1200 400 S4H20 20-2 1600 S7H1200 1600 S7H1200 400 S4H20 Up to 600V 2 Short Circuit Maximum Fuse Range rating size ka, 600VAC A 0.1-0.16 1 0.16-0.2 1 0.2-0.40 1 0.40-0.63 1 0.63-1.0 1 1.0-1.6 1 1.6-2. 1 2. - 4.0 1 4.0-6.3 2 6.3-9.0 3 9.0-12. 0 12. - 16 60 16-20 80 20-2 100 0.1-0.16 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.2-0.40 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.40-0.63 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.63-1.0 1200 S7H1200 1200 S7H1200 1200 S7H1200 1.0-1.6 1200 S7H1200 1200 S7H1200 1200 S7H1200 1.6-2. 1200 S7H1200 1200 S7H1200 1200 S7H1200 2. - 4.0 1200 S7H1200 1200 S7H1200 1200 S7H1200 4.0-6.3 1200 S7H1200 1200 S7H1200 1200 S7H1200 6.3-9.0 1200 S7H1200 1200 S7H1200 20 S4H20 9.0-12. 1200 S7H1200 1200 S7H1200 12. - 16 1200 S7H1200 1200 S7H1200 16-20 1200 S7H1200 20 S4H20 20-2 1200 S7H1200 20 S4H20 1 Fuse: Rated 1600A, Listed Class L. All others, listed RK. Both time delay fuses. 2 Fuse: Rated 1600A, Listed Class L. All others, listed K. Both time delay fuses.

Technical data Type MS40/41, MS49, 6, 7 Short circuit protection Manual motor protectors Catalog number MS4x Series UL 08 Manual Motor Controller Group Installation Motor Disconnect UL 08 Manual Self-Protected (Type E) Combination Motor Controller Max. Short Circuit Current [ka] Max. Fuse or C.B. Max. Short Circuit Current [ka] Max. Short Circuit Current [ka] For Use With Contactors Below per NEC 480V / 480Y/277V 600Y/347V (or larger) 600V 480V 600V 480Y/277V 600Y/347V MS40-16 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-16 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-20 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-20 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-2 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-2 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-32 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-32 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-40 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-40 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-4 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-4 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS40-0 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS41-0 6 2 00 A/AE/AL/AF30,40,0 6 2 6 2 MS49x Series MS49-40 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS496-40 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS49-0 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS496-0 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS49-63 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS496-63 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS49-7 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS496-7 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 30 MS49-90 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 ~ MS496-90 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 ~ MS49-100 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 ~ MS496-100 6 30 00 A/AE/AF0,63,7,9,110 6 30 6 ~

Manual motor protectors Approximate dimensions MS32 00.00 00.00 Inches [Millimeters] MS32 0.3 9 1.06 27 1.06 27 1.77 2.13 4 4 2.66 67. 2.9 7 1.9 49. 3.4 90 1.77 4 HK, SK, AS RC32 MS32 Power feed terminal blocks for MS32 1.73 44.0 0.24 6.0 0.86 22. 1.71 1.42 43. 36.0 0.71 18.0 0.16 4.0 0.047 1.2 0.39 10.0 Connection terminal block for busbar and 4 AWG / 2mm wire 2.0 2.0 0.24 6.0 0.89 22. 1.26 32.0 0.91 23.0 0.16 4.0 0.71 0.047 18.0 1.2 Connection terminal block for busbar and 4 AWG / 2 mm wires

Approximate dimensions Accessories for MS32 Manual motor protectors 00.00 00.00 Inches [Millimeters] Busbar connectors for MS32 4.29 109.0 0.71 1.10 0.16 18.0 28.0 4.0 Busbar Connector (2 x MS 32 with 1 aux.contact) 9.2 23.0 0.41 10. 0.77 19. 1.16 29. 0.71 1.10 0.16 18.0 28.0 4.0 Busbar Connector (4 x MS 32 with aux.contact) 0.047 1.2 Molded plastic enclosures for MS32 & IB32-Y/G

Manual motor protectors 00.00 00.00 Inches [Millimeters] 0.71 18 1.38 3 2.16 0.71 18.8 148. 4.49 114.1 140 C.L. 0.71 18 2.76 70 0.71 18 7.09 180 6.0 16 C.L.