Technical Information

Similar documents
FMotor Circuit Controllers

FMotor Circuit Controllers

ACS motor protection circuit breakers KT 7 Introduction

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Motor Controllers + Circuit Breakers

FMotor Circuit Controllers & Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

Technical Information

Bulletin 190-M Compact Starters. Selection Guide

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

KT4 Manual Motor Starter

Industry Automation Control Components

KT4 Manual Motor Starters

Ideal for use as a manual starter

Enclosed Molded Case Circuit Breakers

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Bulletin 140M Motor Protectors

3VU13, 3VU16 Circuit-Breakers

Low voltage switch gear

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Protection Equipment. 5/2 Introduction

Ktec Contactors and thermal overloads

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

AF series contactors (9 2650)

Protection Equipment

General data 5/37. Overview

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

XT IEC Power Control Manual Motor Protectors

Components for EEx e Panels

UMBW-UL489 and UL1077 Listed

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

Electromagnetic Industries LLP

Miniature Circuit Breakers

Essential equipment for all your requirements

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Motor Starting Solutions Open Type Version, in Kit Form

AF series contactors (9 2650)

ABB s new control and protection devices

3 - Protection components Motor circuit-breakers

Manual Motor Starters. Meta-MEC

CI-TI Contactors and motor starters Types CI 61 - CI 98

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Short form catalogue Motor protection and control Manual motor starters

Manual Motor Starters

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

DPX moulded case circuit breakers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Self-protected Combination Starters System PKZ 2-SP

Short form catalogue. Motor protection & control

Typical UL489 Application Power Circuit of a UL508A Panel

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

MAGNETIC MOTOR STARTERS

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Jtec 10kA Miniature Circuit Breaker

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

CI-TI Contactors and Motor Starters Type CI 6-50

Circuit breakers for power distribution A1 Ordering information

Star Series Motor protection & control

A7 Magnetic Contact/Switch CONTENTS

MS General Information Extended Product Type: MS

SECTION MOTOR CONTROL

Technical Section: Miniature Circuit Breakers

AF40... AF96 3-pole contactors Technical data

US Catalog. Motor protection and control AF Range contactors & overload relays

SIRIUS 3RU2 Thermal Overload Relays

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Bimetal Overload Relays 3UA and 3UC

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

GLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features

Micro Contactor MA Series

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Protective Devices: Circuit-Breakers 1 )

Molded Case Circuit Breakers

Softstarters Type PSS. Softstarters. General information

Control Circuit Protection

Starting of Induction Motors

TeSys GV2 - GV3 Manual Starters and Protectors

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Selection Guide Motor Control Device Solutions

Protection components

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Typical UL1077 Application

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Technical Information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

825-P Modular Protection System for motors Specification Guide

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Transcription:

Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors against overload. The curve shows the mean operating current at an ambient temperature of 20 C starting from the cold state. Careful testing and setting ensures effective motor protection even in the case of single-phasing. The overload characteristic is also valid for transformer protection. 2. Magnetic Release Trip Current The instantaneous magnetic trip has a fixed operating current setting. This corresponds to 13 times the maximum value of setting range (high inrush protection -20 x I e maximum). At a lower overload setting the magnetic trip is correspondingly higher. Current Setting I ef The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC 947-4-1. If a different value is prescribed (e.g., reduced I e for cooling medium having a temperature higher than 40 C or a place of installation higher than 2000 m above sea level), the setting current is equal to the reduced rated current I e of the motor. Cut-off Current KT7-2S F KT7 F29

Technical Information KT7 Controller Cut-off Current KT7-2H and KT7-H FKT7 F30

Wiring Diagrams KF7 with KT7 Controller KF7 Fuse Holder used with CA7 Contactor KF7 Fuse Holder used with KTA7 Controller and CA7 Contactor F KT7 F31

KT7 Controller KT7 Bus Bar and Supply Blocks CA7/KT7 Connection Modules and Kits 1) Ecombo Modules Electrical and mechanical connection between motor circuit controller and contactors with AC coil. For CA7-9...23 only. Compatible with the reversing- and WYE-delta starter components. FKT7 2) Standard Connection Modules Electrical connection between motor circuit controller and contactors with AC coil. For CA7-9... Compatible with the reversing- and WYE-delta starter components. 3) Coil Extension Modules Simplifies access to the coil terminals on 3-component starters. For CA7-9...23 = KT7-2S-PSC23 For CA7-30...43 = KT7-H-PSC43 F32

KT7 Controller KT7 Design B (without Terminal Adaptor KT7-2[]-TE) KT7-2 Design C (without Terminal Adaptor KT7-2-TE1) 6 ➊ 4, 90 ➊ 24,8 4, 44 70 4, 4 80 F ➊ Mounting on 3 mm DIN Rail EN 0 022-3 ➋ Auxiliary contact (side-mounted). Adds 9mm (23/64) ➌ Undervoltage trip or Shunt trip ➍ Auxiliary contact (front-mounted) KT7-2S KT7-2H KT7 F33

KT7 Controller KT7 Design B (with Terminal Adaptor KT7-2[]-TE) KT7-2-TE1 KT7-2S with Terminal Adaptor KT7-2-TE (KT7-2S) KT7-2H with Terminal Adaptor KT7-2-TE KT7-2-TE1 KT7-H with Terminal Adaptor KT7--TE (KT7-2H) KT7-2 Design C (with Terminal Adaptor KT7-2-TE1) 44,7 42,4 4,9 43,9 24,8 13,9 64,9 3,9 34,8 23,9 1 1 3 3 3 3 1 1 10 ( 10 ) ( ) ( 10 ) 10 ( ) ( 4,9 ) ( 64,9 ) KT7-2S with Terminal Adaptor KT7-2-TE1 KT7-2H with Terminal Adaptor KT7-2-TE1 Mounting Position KT7-2S, KT7-2H, KT7-H 3,7 99 49,3 91 FKT7 T3 T2 T1 8,8 63,6 F34 T1 T2 T3,7 ( 63,6 )

KT7 Controller KT7 Controller Door Coupling Handle KT7-HTC Coupling is included in Door Handle Kits KT7-HTN and KT7-HTRY. This coupling replaces the knob shipped as standard on the controller. Design D Door Coupling Handle Kits include an interface for the Stops molded into Design C KTA7/KTB7/KTC7, which inhibits excessive rotation of the handle mechanism. The old Design C Door Handle Kits will fit new Design C (shipped in WHITE boxes), but will not take advantage of the Stops. Design D Door Handle Kits are backward compatible. Includes 20mm Shaft KT7-HT a Includes 400mm Shaft KT7-HTL b No Shaft c1 c2 KT7-2S 117 338 (4.6 13.3 in) 117 488 (4.6 19.2 in) 10. ± 49. 40. KT7-2H KT7-H 126 347 (.0 13.7 in) 148.6 369.6 (.4 14. in) 126 497 (.0 19.6 in) 148.6 19 (.4 20.4 in) 114. ± 49. 40. 137.1 ± 9.3 0.3 F KT7 F3

Mounting Modules Type W Mounting Modules & Spacer 12 9 8 FKT7 228 Catalog Number A B C D E F W-32489 (KA7-WSRR) W-32490 (KA7-WSRR) W-32496 (KA7-WMRR) W-32497 (KA7-WMRR) 228 (8-31/32) 228 (8-31/32) 283 (11-9/64) 283 (11-9/64) (1-2/32) 4 (2-1/8) (1-2/32) 4 (2-1/8) 69 (2-23/32) 69 (2-23/32) 69 (2-23/32) 69 (2-23/32) 16. (6-3/64) 174 (6-27/32) 166. (6-3/64) 174 (6-27/32) 210 (8-17/64) 210 (8-17/64) 26 (10-7/16) 26 (10-7/16) 3 (1-3/8) 40 (1-37/64) 40 (1-37/64) 40 (1-37/64) Spacer W-329 F36