Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Similar documents
Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Series PAVC Variable Volume, Piston Pumps

Series PVP Variable Volume Piston Pumps

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Variable Displacement Piston Pumps. Performance Information. Features. Specifications. Controls. Schematic Symbol (Basic Pump) Weight and Package Size

Performance Information Series PVP 100/140 Pressure Compensated, Variable Volume, Piston Pumps

Series PVP Variable Volume, Piston Pumps

Series PHP10 Variable Volume, Piston Pumps

Performance Information Series PVP 41/48 Pressure Compensated, Variable Volume, Piston Pumps

High Pressure Gear Pumps & Motors Series PZG Pumps Series MZG Motors

PAVC SERIES VARIABLE VOLUME PISTON PUMP

PowrFlow PVX Vane Pumps

Catalog PowrFlowTM PVX Vane Pumps

Piston Pumps Series P2 / P3 Variable Displacement

LogSplitterPlans.Com

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

P2060 P2075 P2105 P2145 P3105 P3145

Sandwich Valves Series CP

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

HPV-10 AXIAL PISTON PUMPS

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

HPV-15 AXIAL PISTON PUMPS

HPV-15 AXIAL PISTON PUMPS

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

PVP SERIES VARIABLE VOLUME PISTON PUMP

Eaton. Revised June, Heavy Duty Hydrostatic Transmissions. l r. Models 33 through 76 Hydrostatic Transmissions. We Manufacture.

HPVR-10 AXIAL PISTON PUMPS

Colorflow and Ball Valves. Industrial Flow Control, Check, Gauge Control. Catalog HY /US

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Whisper Pumps VPV Vane Pumps

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Heavy Duty Hydrostatic Transmissions

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Series P2/P3 Variable Volume Piston Pumps

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Fixed Displacement Gear Pumps

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

PVE 19 & 21 Piston Pumps

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

WARNING User Responsibility

Hydraulic Pump Division. Product Range - HY /HPD/US. aerospace climate control electromechanical filtration fluid & gas handling

Heavy Duty Hydrostatic Transmissions

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

6000 Series Highlights

Table of Contents. H Series Variable Displacement Piston Pumps

AXIAL PISTON MOTORS MF S E R I E S 2 0 C L O S E D C I R C U I T

PUmP REfEREncE guide Bulletin E

Hydraulics. VPV Vane Pumps. Whisper Pumps. Automation Technology

Vickers. Vane Pumps. Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment.

Variable Displacement Piston Pumps for Industrial Applications

Disc Valve Hydraulic Motors Series 6000

Series 20 Axial Piston Pumps. Technical Information

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Technical Information Series 45 G Frame powersolutions.danfoss.com

Veljan Gear Pumps. 'B' Series Features:

ENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

Variable displacement axial piston pump type V30D

Service and Parts Manual. Minimum Filtration Required:

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

Double Pump Operating Specifications

Disc Valve Hydraulic Motors 2000 Series

Full Range Pressure Compensating Variable Flow Control

DY Series 1-Piece Ball Valves. Catalog 1001C-A. July 2012 欧陆传动

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

6000 Series. Highlights C-5. Description With torque up to 15,000 in-lb and 40 gpm continuous, this motor is packed with power operates very smoothly.

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

MOVICONTROL. Single and Double Fixed Vane Pumps SERIES V10, V20, 25V/VQ, 35V/VQ, 45V/VQ.

External gear pump Series G

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

2.3 MEDIUM HEAVY DUTY SERIES

HP3V SERIES. Swash-plate Type Axial Piston Variable Displacement Pump

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130

Disc Valve Hydraulic Motors 4000 Compact Series

Genuine Metaris MA10VO/VSO Technical Catalog. Variable Displacement Piston Pump - A10V Series 31 & 52

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 )

P.C. Priority Flow Control Valve Series J02D3. General Description

Hydraulic Pump VP1-120

Eaton Fixed Displacement HHD Motor and Variable ACA Pump

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Series 20 Axial Piston Pumps. Technical Information

VIS (Valve-In-Star) Hydraulic Motor

FIXED DISPLACEMENT VANE PUMPS

611H Flo-Con Pressure Regulators & Valves

Veljan Gear Pumps. E' Series Features:-

Gear Housing Widths 1.00" 1.25" 1.50" 1.75" 2.00" 2.25" 2.50" Gear Housing Widths / Flow Rate [ VGP - D Series ]

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

External Gear Pumps Series F

Oildyne. Miniature Piston Pumps 5 Piston Design. Pressures to 276 bar (4000 psi) Displacements from.156cc/rev to.865cc/rev (.01 to.

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Disc Valve Hydraulic Motors

Disc Valve Hydraulic Motors Series 4000

Transcription:

aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement For Open Circuits Catalog: HY28-2662-CD/US Effective: April 1, 212

WARNING - USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. OFFER OF SALE The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document. Copyright 212,. All Rights Reserved.

Contents Series PAVC Contents Introduction...4 Ordering Information...7 Control Options 33/38/65/1...8 Technical Information...13 PAVC 33/38 Technical Information 33/38...14 Performance Data 33/38...15 Dimensional Data 33/38...18 PAVC 65 Technical Information 65...2 Performance Data 65...21 Dimensional Data 65...23 PAVC 1 Technical Information 1...26 Performance Data 1...27 Dimensional Data 1...29 Installation Information 33/38/65/1...34 Offer of Sale...39 3

Introduction Series PAVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery @ 21 bar (3 ) in LPM (GPM) *Approx. Noise Levels db(a) @ Full 18 RPM (12 RPM) 34 bar 69 bar 138 bar 27 bar Input Power At 18 RPM, Maximum Displacement & 27 bar (3 ) Operating Speed RPM (Maximum) Pressure bar () Continuous (Maximum) 12 RPM 18 RPM (5 ) (1 ) (2 ) (3 ) PAVC33 33 (2.) 39.4 (1.4) 59. (15.6) 75 (69) 76 (72) 78 (75) 79 (77) 21.3 kw (28.5 hp) 3 27 (3) PAVC38 38 (2.3) 45. (11.9) 67.8 (17.9) 75 (69) 76 (72) 78 (75) 79 (77) 24.6 kw (33. hp) 3 27 (3) PAVC65 65 (4.) 78.7 (2.8) 118.1 (31.2) 77 (75) 78 (76) 8 (78) 81 (79) 43.1 kw (57.8 hp) 3 27 (3) PAVC1 1 (6.1) 119.6 (31.6) 179.8 (47.5) 83 (77) 82 (78) 82 (79) 85 (8) 71.2 kw (95.5 hp) 26 27 (3) * Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards. 4

Introduction Series PAVC PUMP HOUSING REPLACEABLE PORT PLATE HYDRODYNAMIC BEARING REAR COVER SEALED BEARING SHAFT SEAL CYLINDER BARREL SERVO PISTON Features High Strength Cast-Iron Housing Built-In Supercharger Ensures High Speed Capability 3 RPM (26 RPM PAVC1) Sealed Shaft Bearing Two Piece Design for Ease of Service Cartridge Type Controls Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Thru-Shaft (PAVC1 Only) Full Pressure Rating on Most Water Glycol Fluids Pump Case and Shaft Seal are Subjected to Inlet Pressure Only Filter and/or Cool Drain Line 7 bar (1 ) Maximum Controls Pressure Compensation Load Sensing Power (Torque) Limiting Power and Load Sensing Remote Pressure Compensation Adjustable Maximum Volume Stop Low Pressure Standby 5

Introduction Series PAVC 33/38/65/1 General Description All control is achieved by the proper positioning of the swash plate. This is achieved by a servo piston acting on one end of the swash plate working against the combined effect of the off-setting forces of the pistons and centering spring on the other end. The control spool acts as a metering valve which varies the pressure behind the servo piston. As shown in Figure 1, the amount of flow produced by the Parker Piston Pump is dependent upon the length of stroke of the pumping pistons. This length of stroke, in turn, is determined by the position of the swash plate. Maximum flow is achieved at an angle of 17. The rotating piston barrel, driven by the prime mover, moves the pistons in a circular path and the piston slippers are supported hydrostatically against the face of the swash plate. When the swash plate is in a vertical position, perpendicular to the centerline of the piston barrel, there is no piston stroke and consequently no fluid displacement. When the swash plate is positioned at an angle, the pistons are forced in and out of the barrel and fluid displacement takes place. The greater the angle of the swash plate, the greater the piston stroke. The centerline of the pumping piston assembly is offset from the centerline of the swash plate. Therefore, as shown on the accompanying Figure 1A, the pistons effective summation force tends to destroke the swash plate to a vertical (neutral) position. This destroking force is balanced as the swash plate is angled by the force of the servo piston. ROTATING PISTON BARREL PUMPING PISTON OUTPUT SUMMATION OF PISTON FORCES DRIVE SHAFT INPUT OIL FLOW SWASH PLATE SERVO PISTON FIGURE 1. Pumping Action FIGURE 1A. 6

Ordering Information Series PAVC PAVC 4 Omit Multiple Pumps Pump Axial Piston Variable Controllable Displacement Bearing Option Shaft Option Outlet Port Inlet Port Rotation Volume Stop Adjustable Option Differential Thru- Thru- Control Shaft Shaft Options Nitrile Threads Variations (Standard) Seals Paint Multiple Pumps Code Omit Multiple Pumps Single Pump Factory Mounted to Rear of Another Pump Code Inlet Port 33/38 Inlet 65 Inlet 1 Inlet Type Omit Str. Thd., Rear Str. Thd., Rear Flange, Rear SAE/Inch Threads 2 Flange, Side Flange, Top Flange, Top/Bottom SAE/Inch Threads Code Displacement in 3 /rev (cm 3 /rev) 33 2. (33) 38 2.3 (38) 65 4. (65) 1 6.1 (1) Code Bearing Option Omit Single Piece Shaft 9* Dual Bearing * For applications where side loading may be experienced. Max. side load = 113.4 kg (25 lbs). Typical Applications: Belt/chain drive Universal joint drive Massive couplings Foot mount installations Code Shaft Option Size 33/38 Size 65/1 Omit 7/8" Keyed SAE B 1¼" Keyed SAE C B 13T Spline SAE B 14T Spline SAE C C* 1½" Keyed SAE CC D* 17T Spline SAE CC * Size 1 only Code Outlet Port Outlet Location Type Omit Str. Thread Top SAE/Inch 3* Flange Top SAE/Inch * Size 1 only Chart #1 Item Setting RPM HP Code Rotation* R Right CW L Left CCW * Viewed from shaft end. Code Volume Stop Options Omit Volume Stop Plugged 2 Maximum Volume Stop 5* Max. Volume Stop with O-ring * Not available with Thru- Shaft option on Size 1. Code Thru-Shaft Threads* Omit No Thru-Shaft 6 Thru-Shaft, UNC * Available on Size 1 only. Code Omit A3 A4 *B3 *B4 *C3 Ordering Notes Unless otherwise specified, pump is shipped at maximum GPM (18 RPM) and set to 69 bar (1 ) [See Exceptions]. When factory settings are required, the items shown in Chart #1 must be included with order. Thru-Shaft Variations No Thru-Shaft Option Thru-Shaft, SAE AA Pilot, 9 Tooth 2/4 Pitch Spline Coupling, PAVC 1 Only Thru-Shaft, SAE A Pilot, 9 Tooth 16/32 Pitch Spline Coupling, PAVC 1 Only Thru-Shaft, SAE B Pilot, 13 Tooth 16/32 Pitch Spline Coupling, PAVC 1 Only Thru-Shaft, SAE B Pilot, 15 Tooth 16/32 Pitch Spline Coupling, PAVC 1 Only Thru-Shaft, SAE C Pilot, 14 Tooth 12/24 Pitch Spline Coupling, PAVC 1 Only Inlet port option 2 or 8 (top/bottom) must be used with all Thru-Shaft pumps. * Use SAE C-C shaft on thru-shaft pump variation when combined input torque of front and rear pumps exceeds 565 N m (5 In-Lbs). Code Control Option Standard Pressure Compensated Omit Setting Pressure 41-27 bar (6-3 ) A Pressure & (Load Sensing) *C Pressure, & Power *H Pressure Comp. & Power ** M Remote Pressure ** ME Remote Pressure AM Remote Pressure & * CM Remote Pressure, & Power * HM Remote Pressure & Power * Power controlled pumps (H, C, HM or CM) must have maximum input power limit specifications at a particular drive speed (RPM) and compensator pressure setting () included with order. Power controlled pumps that do not have input power limit specifications, will be set at default setting (22.5 HP @ 18 RPM and 3 ) H & C (6 HP @ 18 RPM and 3 ) HM & CM ** M may be remotely controlled; ME requires external pilot Pumps with M, ME, AM, CM or HM controls will be set to compensate at 27 bar (3 ) unless Chart #1 specifies otherwise. Code Omit P No Paint Paint Painting Code Multiple Pumps Omit Single Pump Pump Factory Mounted on Rear GPM = Omit if not required or to select standard option coded omit. 7

Control Options Series PAVC 33/38/65/1 Pressure Compensated Control Swash plate angle controls the output flow of the pump. Swash plate angle is controlled by the force generated against the swash plate by the pumping pistons and by the force of the servo piston. The force of the servo piston is greater than the force of the pumping pistons when both are at the same pressure. By means of internal porting, pressure is connected from the output port to the servo piston via orifice (E), and to the control spool via passage (D). Also pressure is applied to the control spool chamber thru orifice (F). As long as the pressures at both ends of the control spool remain equal, the spool will remain offset upward, due to the added force of the spring. When pressure reaches the setting of the compensator control, the dart leaves its seat causing the pressure in the spool chamber to be reduced. The spool now moves downward causing pressure in the servo piston cavity to vent via port A. The reduced pressure at the servo piston allows the servo piston to move to the right. This movement reduces the angle of the swash plate and thereby reduces the pumps output flow. As pump pressure on the control spool drops below pressure and spring force in the spool chamber, the control spool moves upward to maintain an equilibrium on both sides of the spool. If pump pressure falls below compensator control setting, the control spool moves up, bringing the pump to maximum displacement. P Adjustment of PAVC Pumps PROCEDURE: a. Standard Pressure Compensated Pump Pumps are shipped from factory with a differential pressure of approximately 15 (1 bar) on PAVC 33/38/65, PAVC 1 is 3 (21 bar) at 5% of maximum swash angle. Differential pressure will not normally change through the life of the pump. If this control has been tampered with, a close approximation of the correct setting can be made as follows: Dead head the pump (no flow) with a -27 bar (-3 ) gauge in the OUTLET (not the low signal B port), back the pressure compensator adjustment out (full counterclockwise). The gauge should read between 22-26 bar (325-375 ) PAVC 33, 38 & 65, 34-4 bar (5-575 ) PAVC 1. If the gauge reads different than this, turn the differential adjustment knob (Differential Option 4) or add/remove shims (Omit Option) until correct pressure figure is reached. CONTROL OPTION - OMIT SWASHPLATE PISTON AIRBLEED VALVE ASSEMBLY OUTLET FLOW (AT CONSTANT SPEED) INLET BARREL D PRESSURE PISTON SERVO PISTON E CONTROL SPOOL AND SLEEVE CONTROL DRAIN PORT A F CONTROL SPOOL SPRING CHAMBER PRESSURE COMPENSATOR ADJUSTMENT DIFFERENTIAL ADJUSTMENT 8

Control Options Series PAVC 33/38/65/1 Remote Pressure Control Control Type (M) Remote control of the PAVC output pressure can be achieved by controlling the pressure in the low signal B port when the pump is set up for Control Type (M). A manual, hydraulically piloted, electrical or electroproportionally controlled pressure control device is installed in the line from the low signal B port to tank. The pump will then maintain pressure approximately equal to the pressure in the B port plus the pump differential setting. Multiple Pressure Standby If the pressure level in the low signal B port is limited by a relief valve, as the desired pump outlet pressure is reached, the relief valve in the B port will allow the pump to standby at a preset pressure. Adding to this concept, multiple, remotely piloted relief valves plumbed in parallel in the B port line can yield multiple, sequential pressure settings. Low Pressure Standby This option can be used as an alternative to the load sensing option (A) to achieve low pressure standby. Minimum standby pressure is somewhat higher than that achieved using option (A). In the compensating mode there is approximately 1.1 LPM (.3 GPM) flow from the low signal B port in addition to 3.4 LPM (.9 GPM) flow from the control drain port A. CONTROL OPTION - M SWASHPLATE PISTON AIRBLEED VALVE ASSEMBLY OUTLET FLOW (AT CONSTANT SPEED) PRESSURE INLET BARREL D PISTON SERVO PISTON E CONTROL SPOOL AND SLEEVE PORT B F CONTROL DRAIN PORT A CONTROL SPOOL SPRING CHAMBER PRESSURE COMPENSATOR ADJUSTMENT DIFFERENTIAL ADJUSTMENT 9

Control Options Series PAVC 33/38/65/1 Pressure & Control (Load Sensing) Control Type (A) control is achieved by placing an orifice (fixed or adjustable) in the pump outlet port. The pressure drop ( P) across this flow control is the governing signal that controls the pump s output, as explained below. Whenever the pressure drop at the flow control increases (indicating an increase in output flow), the pump attempts to compensate by decreasing the output flow. It does this by sensing the lower pressure on the downstream side of the flow control via line (C), which is balanced against the pump pressure via passage (D), on the control spool. The control spool is forced down against the control spool spring by differential pressure. This vents the servo piston cavity, destroking the pump to a point where the set pressure drop across the orifice is maintained and the flow is obtained. The converse of this is also true whenever the pressure drop decreases (indicating a decrease in output flow). In this case, the control spool is forced up. This increases pump displacement in an attempt to maintain the predetermined pressure drop or constant flow. It should be noted that the pump is still pressure compensated and destrokes at the selected pressure setting. The pressure compensator control will override the flow control whenever the pressure compensator control setting is reached. Low Pressure Standby This arrangement can also be used to provide low pressure standby by venting the B port through a simple on/off valve suitable for flows of 3.8-7.6 LPM (1-2 GPM). When flow or pressure is required, this valve is closed allowing system pressure to build behind the control spool and bringing the pump on-stroke. Load Sensing If, instead of measuring the pressure drop across the orifice in the pump outlet port, it is measured downstream of a directional control valve, a constant pressure drop will be maintained across the valve spool. This results in a constant flow for any given opening of the directional control valve regardless of the work load downstream or the operating speed of the pump. The pump senses the amount of pressure necessary to move the load and adjusts output flow to match the valve opening selected and pressure to overcome the load plus the preset P across the valve spool. The benefits of this arrangement are that excellent, repeatable flow characteristics are achieved, and considerable energy savings are realized while metering, compared to using a straight pressure compensated system. CONTROL OPTION - A INLET SWASHPLATE BARREL PISTON AIRBLEED VALVE ASSEMBLY D FLOW CONTROL ADJUSTMENT SYSTEM PRESSURE FLOW (AT CONSTANT SPEED) PRESSURE PISTON SERVO PISTON E CONTROL SPOOL AND SLEEVE C SIGNAL LINE F PORT B CONTROL DRAIN PORT A CONTROL SPOOL SPRING CHAMBER PRESSURE COMPENSATOR ADJUSTMENT DIFFERENTIAL ADJUSTMENT 1

Control Options Series PAVC 33/38/65/1 Pressure & Power (Torque) Control Control Type (H) The power control is sensitive to the position of the servo piston. When the servo piston is to the right, the swash plate causes low flow and the power control piston develops maximum spring pressure on its companion poppet (mechanical feedback). When the servo piston is left and the flow is high, the power control piston reduces spring pressure on the poppet. This allows it to open under less pressure in the control spool chamber, thereby venting some of the pressure in the control spool chamber. As with the operation of the pressure compensator control, this allows the control spool to move downward, venting the servo piston cavity and causing the servo piston to move to the right. This reduces output flow and thereby power. As indicated in the pictorial drawing, pressure in the control spool chamber is affected by both the pressure compensator control and the power control. The resultant pressure in this chamber is a function of the set points of these two controls. Both set points are adjustable. CONTROL OPTION - H SWASHPLATE AIRBLEED VALVE ASSEMBLY FLOW (AT CONSTANT SPEED) PRESSURE PISTON OUTLET INLET BARREL D PISTON POWER CONTROL PISTON SERVO PISTON E CONTROL SPOOL AND SLEEVE CONTROL DRAIN PORT A F CONTROL SPOOL SPRING CHAMBER POWER (TORQUE) ADJUSTMENT PRESSURE COMPENSATOR ADJUSTMENT DIFFERENTIAL ADJUSTMENT 11

Control Options Series PAVC Pressure, Power & Control Control Type (C) In addition to the three control configurations just discussed, it is possible to combine all three control devices in one pump. In this mode, the position of the control spool is a function of the actions of the pressure compensator adjustment, power adjustment, and flow control. CONTROL OPTION - C FLOW (AT CONSTANT SPEED) PRESSURE SWASHPLATE AIRBLEED VALVE ASSEMBLY FLOW CONTROL ADJUSTMENT PISTON SYSTEM PRESSURE INLET BARREL D PISTON POWER CONTROL PISTON SERVO PISTON CONTROL DRAIN PORT A E CONTROL SPOOL AND SLEEVE SIGNAL LINE F CONTROL SPOOL SPRING CHAMBER C PORT B POWER (TORQUE) ADJUSTMENT PRESSURE COMPENSATOR ADJUSTMENT DIFFERENTIAL ADJUSTMENT 12

Technical Information Series PAVC 33/38/65/1 How to read input power control curve data. FLOW LPM GPM 6.6 (16) 18 RPM KW HP 18.6 (25) 14.9 (2) N m 9.4 In-Lbs (8) 53. 45.4 37.9 3.3 22.7 15.1 (14) (12) (1) (8) (6) (4) 11.2 7.5 3.7 (15) (1) (5) Input Power 67.8 45.2 22.6 (6) (4) (2) Input Torque 7.6 (2) () Bar () 69 138 (1) (2) Pressure POWER 27 (3) () () 1. Power A curve corresponds to flow A curve. This represents a particular setting of the power (torque) control. 2. With this setting the maximum power required will be as shown at the apex (maximum point) of the power curve. 3. The flow at this setting will follow the flow vs. pressure curve shown. 4. Example 18 RPM, curve labeled C : A. will follow curve C and pump will deadhead at 19 bar (275 ). B. Full flow will not be realized above 83 bar (12 ). C. at 13 bar (15 ) will be approximately 48.1 LPM (12.7 GPM). D. Maximum power [11 KW (15 HP)] occurs at approximately 117 bar (17 ). 5. Torque values are shown to correspond to powers at speed shown. 13

Technical Information Series PAVC 33/38 Performance Information Series PAVC 33/38 Pressure Compensated, Variable Volume, Piston Pumps Features High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability 3 RPM Two Piece Design for Ease of Service Cartridge Type Controls Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable 7 bar (1 ) Maximum Controls Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Low Pressure Standby Schematic Symbol (Basic Pump) Weight and Package Size Model Quick Reference Data Chart Pump Model Weight In Kg (Lb) Length From Mounting Face in CM (Inches) Displacement CM 3 /REV (IN 3 /REV) Height in CM (Inches) Pump Delivery @ 21 bar (3 ) in LPM (GPM) Height in CM (Inches) PAVC 33/38 18 (4) 18.41 (7.25) 16. (6.3) 16.81 (6.62) Specifications Pressure Ratings: Outlet Port: Inlet Port: Control Drain: 27 bar (3 ) Continuous (P1) 248 bar (36 ) Peak (P3) 1.72 bar (25 ) Maximum.17 bar (5 In. Hg.) Minimum @ 18 RPM (See Inlet Chart for other speeds) 7 bar (1 ) Maximum Speed Ratings: 6 to 3 RPM Operating Temperature Range: 4 C to 71 C ( 4 F to 16 F) Housing Material: Cast-Iron Filtration: Maintain SAE Class 4, ISO 16/13, ISO 18/15 Maximum Recommended Mounting: SAE B 2-Bolt Flange Mount or Diagonally on SAE B 4-Bolt Flange Mount. Installation Data: See page A46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps. *Approx. Noise Levels db(a) @ Full 18 RPM (12 RPM) 34 bar (5 ) 69 bar (1 ) 138 bar (2 ) 27 bar (3 ) Input Power At 18 RPM, Max. Displacement & 27 bar (3 ) 12 RPM 18 RPM PAVC33 33 (2.) 39.4 (1.4) 59. (15.6) 75 (69) 76 (72) 78 (75) 79 (77) 21.3 kw (28.5 hp) PAVC38 38 (2.3) 45. (11.9) 67.8 (17.9) 75 (69) 76 (72) 78 (75) 79 (77) 24.6 kw (33. hp) * Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards. 14

Performance Data Series PAVC 33/38 Typical Performance Data - Fluid: Standard Hydraulic Oil 1 SSU @ 49 C (12 F) Efficiency - % 1 9 8 7 LPM GPM 113.6 (3) 12.2 (27) 9.9 (24) 79.5 (21) PAVC33 @ 18 RPM Volumetric Efficiency Overall Efficiency KW 26.1 HP (35.) Efficiency - % 1 9 8 7 LPM 113.6 12.2 9.9 79.5 GPM (3) (27) (24) (21) PAVC38 @ 18 RPM Volumetric Efficiency Overall Efficiency KW HP 26.1 (35.) 6 68.1 57.8 (18) (15) 22.4 (3.) 18.6 (25.) 6 68.1 57.8 (18) (15) 22.4 (3.) 18.6 (25.) 45.4 34.1 22.7 11.4 (12) Bar (9) (6) (3) () () Input Power at Full Compensated Power 69 (1) Pressure 138 (2) 14.9 11.2 7.5 3.7 27 (3) (2.) (15.) (1.) (5.) () Power 45.4 34.1 22.7 11.4 (12) (9) (6) (3) () Bar () Input Power at Full Compensated Power 69 (1) Pressure 138 (2) 27 (3) 14.9 (2.) 11.2 (15.) 7.5 3.7 (1.) (5.) () Power NOTE: The efficiencies and data in the graph are good only for pumps running at 18 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: Inlet Pressure Vacuum Inlet Characteristics at Full Displacement bar.41.28.14 (6) (4) (2) bar In-Hg ().17.34.51 (5) (1) (15) [ ] HP = Q x () 1714 (Graph only valid at sea level) Recommended Operating Condition + (CHp) Actual GPM is directly proportional to drive speed and maximum volume setting. loss, however, is a function of pressure only. DO NOT OPERATE IN THIS REGION WHERE: Q = Actual Output in GPM = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 18 RPM (from graph read at operating pressure) Drain LPM GPM 5.7 (1.5) 4.5 3.4 2.3 1.1 (1.2) (.9) (.6) (.3) Compensated Control Drain @ 18 RPM.68 (2) 5 1 15 2 25 3 Shaft Speed - RPM Bar () () 69 (1) 138 (2) System Pressure 27 (3) 15

Performance Data Series PAVC 33/38 Typical Performance Data - Minimum Power Settings Attainable With Control Options C, H, CM & HM Power KW 22.4 17.9 13.4 8.9 4.5 HP (3) (24) (18) (12) (6) PAVC33 () 5 1 15 2 25 3 Shaft Speed - RPM 27 bar (3 ) 172 bar (25 ) 138 bar (2 ) Full Boundary 13 bar (15 ) 69 bar (1 ) Outlet @ Max. Displacement LPM GPM 151.5 (4.) 113.6 75.7 37.9 (3.) (2.) (1.) PAVC33 vs. Shaft Speed () 5 1 15 2 25 3 Shaft Speed - RPM NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure. Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved. Power (Torque) Limiting Curves LPM 6.6 53. 45.2 37.8 3.3 22.7 15.1 7.6 GPM (16) (14) (12) (1) (8) (6) (4) (2) PAVC33 @ 12 RPM KW HP 14.9 (2) 11.2 (15) 7.5 (1) 3.7 (5) Input Power N m 9.4 67.8 45.2 22.6 In-Lbs (8) (6) (4) (2) Input Torque LPM 75.7 68.1 6.6 53. 45.2 37.8 3.3 22.7 15.1 7.6 GPM (2) (18) (16) (14) (12) (1) (8) (6) (4) (2) PAVC33 @ 18 RPM KW HP 18.6 (25) 14.9 (2) 7.5 Input Power 11.2 (15) (1) 3.7 (5) N m 9.4 67.8 45.2 22.6 In-Lbs (8) (6) (4) (2) Input Torque () Bar () 69 (1) 138 (2) Pressure 27 (3) () () () Bar () 69 (1) 138 (2) Pressure 27 (3) () () See page 12 for How to Read Curves information. 16

Performance Data Series PAVC 33/38 Typical Performance Data - Minimum Power Settings Attainable With Control Options C, H, CM & HM Power KW 22.4 17.9 13.4 8.9 4.5 HP (3) (24) (18) (12) (6) PAVC38 () 5 1 15 2 25 3 Shaft Speed - RPM 27 bar (3 ) 172 bar (25 ) 138 bar (2 ) Full Boundary 13 bar (15 ) 69 bar (1 ) Outlet @ Max. Displacement LPM 151.5 113.6 75.7 37.9 GPM (4) (3) (2) (1) () PAVC38 vs. Shaft Speed 5 1 15 2 25 3 Shaft Speed - RPM NOTE: Minimum attainable HP setting means that input horsepower will not exceed the indicated setting at the indicated R P M a n d t h a t t h e p u m p w i l l a c h i eve f u l l compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure. Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved. Power (Torque) Limiting Curves LPM 6.6 53. GPM (16) (14) PAVC38 @ 12 RPM KW HP 14.9 (2) N m In-Lbs 9.4 (8) LPM 75.7 GPM (2) PAVC38 @ 18 RPM KW HP 29.8 (4) 26.1 (35) N m In-Lbs 135.6 (12) 45.2 37.8 3.3 22.7 15.1 (12) (1) (8) (6) (4) 11.2 (15) 7.5 (1) 3.7 (5) Input Power 67.8 45.2 22.6 (6) (4) (2) Input Torque 56.8 37.8 18.9 (15) (1) (5) 22.4 (3) 18.6 (25) 14.9 (2) 11.2 (15) 7.5 (1) Input Power 113. (1) 9.4 (8) 67.8 (6) 45.2 (4) Input Torque 7.6 (2) 3.7 (5) 22.6 (2) () Bar () 69 (1) 138 (2) Pressure 27 (3) () () () Bar () 69 (1) 138 (2) Pressure 27 (3) () () See page 12 for How to Read Curves information. 17

VARIABLE VOLUME PUMP CC/REV MAX INITIAL FACTORY SETTINGS BELOW HP GPM HYDRAULIC PUMP/MOTOR DIVISION OTSEGO,MICH. 4978 USA ROTATION RPM Catalog HY28-2662-CD/US Dimensional Data Series PAVC 33/38 Rear Ported Pump Dimensions * Inch equivalents for millimeter dimensions are shown in (**). NOTE: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise rotation pump. INLET PORT 1-5/8-12UN-2B ST. THREAD O-RING SAE-2 31.75 (1.25) 74.68 (2.94) 63.5 (2.5) SHAFT OPTION OMIT SAE B SHAFT 7/8" KEYED MAX. TORQUE = 29 N m (1,85 IN-LBS) OUTLET PORT 1-1/16-12UN-2B ST. THREAD O-RING SAE-12 25.4 (1.) 31.75 (1.25) 25.4 (1.) 63.5 (2.5) VENT & FILL PLUG 14.224 (.56) 14.986 (.59) 74.68 (2.94) 98.55 (3.88) 84.7 (3.31) 72.89 (2.87) 63.5 (2.5) 65.28 (2.57) AIRBLEED DRAIN PORT 7/16-2UNF-2B ST. THREAD O-RING SAE-4 Rear View 84.7 (3.31) 72.89 (2.87) 63.5 (2.5) 35 115.6 (4.53) Front View 18.79 (.74) 96.77 (3.81) CLEARANCE FOR.5 DIA. MOUNTING BOLTS. SAE B 2-BOLT PATTERN CLEARANCE FOR.5 DIA. BOLTS MOUNTED DIAGONALLY ON SAE B 4-BOLT PATTERN NON-ADJUSTABLE DIFFERENTIAL OPTION OMIT ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (2 ) PER TURN 6.35 (.25) WIDE KEY 25.9 (.988) 24.73 (.974) 11.6 (4.) Ø 11.54 (3.998) 22.22 (.875) Ø22.19 (.874) LOW SIGNAL PORT B 7/16-2UNF-2B ST. THREAD O-RING SAE-4 44.45 (1.75) CONTROL DRAIN PORT A 7/16-2UNF-2B ST. THREAD O-RING SAE-4 SHAFT OPTION S SAE B SHORT SHAFT 7/8" KEYED MAX. TORQUE = 29 N m (1,85 IN-LBS) 12.7 (.5) 2.57 (.81) Top View 58.67 (2.31) 9.39 (.37) 25.4 (1.) 41.15 (1.62) A 184.15 (7.25) OPTIONAL LOW SIGNAL PORT (PORT B ) B 52.32 (2.6) 74.68 (2.94) TORQUE CONTROL ADJUSTMENT: 56 N m (5 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT: 55 BAR (8 ) PER TURN Side View ROTATION ARROW 27.69 (1.9) MAX 41.4 (1.63) MAX.VOLUME STOP OPTION 2 2.2 CC/REV/TURN (PAVC33) 2.5 CC/REV/TURN (PAVC38) SHAFT OPTION B SAE B SPLINED SHAFT 13 TOOTH 16/32 PITCH MAX. TORQUE = 29 N m (1,85 IN-LBS) 61.97 (2.44) MAX MAX.VOLUME STOP OPTION 5 2.5 CC/REV/TURN (PAVC33) 2.8 CC/REV/TURN (PAVC38) 18

VARIABLE VOLUME PUMP CC/REV MAX INITIAL FACTORY SETTINGS BELOW HP GPM HYDRAULIC PUMP/MOTOR DIVISION OTSEGO,MICH. 4978 USA ROTATION RPM Catalog HY28-2662-CD/US Dimensional Data Series PAVC 33/38 Side Ported Dimensions * Inch equivalents for millimeter dimensions are shown in (**). NOTE: 1. Shown and dimensioned is a clockwise pump. Ports A and B, delivery port and pump controls will be on the opposite side for a counterclockwise pump. 15.92 (4.17) 89.66 (3.53) Port Location Option Outlet Port Inlet Port Control Drain Signal Port 2 SAE-12 Straight Thread (1-1/16-12UNC) OUTLET PORT SEE CHART FOR SIZE 1-1/4 SAE 4-Bolt Flange 7/16-14UNC Threads Standard Pressure Series (Code 61) 25.4 (1.) 63.5 (2.5) SAE-4 Straight Thread (7/16-2UNF) VENT & FILL PLUG SAE-4 Straight Thread (7/16-2UNF) 14.65 (4.12) 63.5 (2.5) 74.67 (2.94) 89.41 (3.52) 72.89 (2.87) 63.5 (2.5) Rear View 89.66 (3.53) 72.89 (2.87) 63.5 (2.5) SHAFT OPTION OMIT SAE B SHAFT 7/8" KEYED MAX. TORQUE = 29 N m (1,85 IN-LBS) CLEARANCE FOR.5 DIA. MOUNTING BOLTS. SAE B 2-BOLT PATTERN CLEARANCE FOR.5 DIA. BOLTS MOUNTED DIAGONALLY ON SAE B 4-BOLT PATTERN 6.35 (.25) WIDE KEY 25.4 (1.) 31.75 (1.25) LOW SIGNAL PORT B SEE CHART FOR SIZE 12.7 (.5) 2.57 (.81) 58.67 (2.31) 9.37 (.37) TORQUE CONTROL ADJUSTMENT: 56 N m (5 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT: 55 BAR (8 ) PER TURN Top View 185.93 (7.32) 89.66 (3.53) INLET PORT SAME BOTH SIDES SEE CHART FOR SIZE 14.22 (.56) 14.98 (.59) 74.68 (2.94) 25.9 (.988) 24.73 (.974) 11.6 (4.) Ø 11.54 (3.998) 22.22 (.875) Ø 22.19 (.874) 63.5 (2.5) NON-ADJUSTABLE DIFFERENTIAL OPTION OMIT 58.93 (2.32) 65.28 (2.57) AIRBLEED DRAIN PORT 7/16-2 UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8 Front View 35 115.6 (4.53) 18.79 (.74) CONTROL DRAIN PORT A SEE CHART FOR SIZE ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (2 ) PER TURN 25.4 (1.) 41.15 (1.62) 52.32 (2.6) 74.68 (2.94) 144.53 (5.69) Side View 3.23 (1.19) 27.69 (1.9) MAX SHAFT OPTION S MAX.VOLUME STOP OPTION 2 SAE B SHORT SHAFT 2.2 CC/REV/TURN (PAVC33) 7/8" KEYED 2.5 CC/REV/TURN (PAVC38) MAX. TORQUE = 29 N m (1,85 IN-LBS) SHAFT OPTION B SAE B SPLINED SHAFT 13 TOOTH 16/32 PITCH MAX. TORQUE = 29 N m (1,85 IN-LBS) 61.97 (2.44) MAX MAX.VOLUME STOP OPTION 5 2.5 CC/REV/TURN (PAVC33) 2.8 CC/REV/TURN (PAVC38) 19

Technical Information Series PAVC 65 Performance Information Series PAVC65 Pressure Compensated, Variable Volume, Piston Pump Features High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability - 3 RPM Two Piece Housing for Ease of Service Cartridge Type Controls - Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable - 7 bar (1 ) Maximum Controls Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Low Pressure Standby Schematic Symbol (Basic Pump) Weight and Package Size Model Quick Reference Data Chart Pump Model Weight In Kg (Lb) Length From Mounting Face in CM (Inches) Displacement CM 3 /REV (IN 3 /REV) Height in CM (Inches) Pump Delivery @ 21 bar (3 ) in LPM (GPM) Height in CM (Inches) PAVC65 28 (62) 22.4 (8.82) 18.84 (7.42) 2.32 (8.) Specifications Pressure Ratings: Outlet Port: 27 bar (3 ) Continuous (P1) 248 bar (36 ) Peak (P3) Inlet Port: 1.7 bar (25 ) Maximum.17 bar (5 In. Hg.) Minimum @ 18 RPM (See Inlet Chart for other speeds) Control Drain: 7 bar (1 ) Maximum Speed Ratings: 6 to 3 RPM* * See Inlet Characteristics Chart on page A155 and consider using Dual Inlet Port configuration on page A178 for applications above 27 RPM. Operating Temperature Range: 4 C to 71 C ( 4 F to 16 F) Housing Material: Cast-Iron Filtration: Maintain SAE Class 4, ISO 16/13, ISO 18/15 Maximum Recommended Mounting: SAE C 2-Bolt Flange Mount or Diagonally on SAE C 4-Bolt Flange Mount Installation Data: See page A46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps. *Approx. Noise Levels db(a) @ Full 18 RPM (12 RPM) 34 bar (5 ) 69 bar (1 ) 138 bar (2 ) 27 bar (3 ) Input Power At 18 RPM, Max. Displacement & 27 bar (3 ) 12 RPM 18 RPM PAVC65 65 (4.) 78.7 (2.8) 118.1 (31.2) 77 (75) 78 (76) 8 (78) 81 (79) 43.1 kw (57.8 hp) * Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards. 2

Performance Data Series PAVC 65 Typical Performance Data - Fluid: Standard Hydraulic Oil 1 SSU @ 49 C (12 F) Efficiency - % 1 9 8 7 LPM 113.6 12.2 9.9 79.5 GPM (3) (27) (24) (21) PAVC65 @ 12 RPM Volumetric Efficiency Overall Efficiency KW HP 29.8 (4) 26.1 (35) Efficiency - % 1 9 8 7 LPM GPM 151.4 (4) 136.3 (36) 121.1 (32) 16. (28) PAVC65 @ 18 RPM Volumetric Efficiency Overall Efficiency KW HP 59.7 (8) 52.2 (7) 6 68.1 (18) 22.4 (3) 6 9.6 (24) 44.7 (6) 57.8 45.4 34.1 22.7 (15) (12) (9) (6) Input Power at Full 18.6 (25) 14.9 (2) 11.2 (15) 7.5 (1) Input Power 75.7 6.6 45.4 3.3 (2) (16) (12) (8) Input Power at Full 37.1 (5) 29.8 (4) 22.4 (3) 14.9 (2) Input Power 11.4 (3) () Bar () Compensated Power 69 (1) Pressure 138 (2) 27 (3) 3.7 (5) () 15.1 (4) () Bar () Compensated Power 69 (1) Pressure 138 (2) 7.5 27 (3) (1) () NOTE: The efficiencies and data in the graph are good only for pumps running at 18 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: [ ] HP = Q x () 1714 + (CHp) Actual GPM is directly proportional to drive speed and maximum volume setting. loss, however, is a function of pressure only. WHERE: Q = Actual Output in GPM = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 18 RPM (from graph read at operating pressure) Inlet Pressure Vacuum Inlet Characteristics at Full Displacement bar.41.28.14 (6) (4) (2) bar In-Hg ().17.34.51 (5) (1) (15) (Graph only valid at sea level) Recommended Operating Condition DO NOT OPERATE IN THIS REGION Drain LPM GPM 7.6 (2.) 5.7 (1.5) 3.8 (1.) 1.9 (.5) Compensated Control Drain @ 18 RPM.68 (2) 5 1 15 2 25 3 Shaft Speed - RPM Bar () () 69 (1) 138 (2) System Pressure 27 (3) 21

Performance Data Series PAVC 65 Typical Performance Data - Minimum Power Settings Attainable With Control Options C, H, CM & HM Power KW 44.7 35.8 26.8 17.9 8.9 HP (6) (48) (36) (24) (12) PAVC65 () 6 12 18 24 3 Shaft Speed - RPM 27 bar (3 ) 172 bar (25 ) 138 bar (2 ) 13 bar (15 ) 69 bar (1 ) Outlet @ Max. Displacement LPM 227.4 17.3 113.6 56.8 GPM (6) (45) (3) (15) () PAVC65 vs. Shaft Speed 5 1 15 2 25 3 Shaft Speed - RPM NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure. Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved. LPM 75.7 56.8 37.9 18.9 GPM (2) (15) (1) (5) PAVC65 @ 12 RPM PAVC65 Power (Torque) Limiting Curves @ 18 RPM KW HP 33.6 (45) 29.8 (4) 26.1 (35) 22.4 (3) 18.6 (25) 14.9 (2) 11.2 (15) 7.5 (1) 3.7 (5) Input Power N m In-Lbs 226. (2) 226. (16) 113. (8) 56.5 (4) Input Torque 169.5 (12) LPM GPM 132.5 (35) 113.6 94.6 75.7 56.8 37.9 18.9 (3) (25) (2) (15) (1) (5) KW HP 52.2 (7) 44.7 (6) 37.3 (5) 29.8 (4) Input Power 22.4 (3) 14.9 (2) 7.5 (1) N m In-Lbs 226. (2) 169.5 (15) 113. (1) 56.5 (5) Input Torque () Bar () 69 (1) 138 (2) Pressure 27 (3) () () () Bar () 69 (1) 138 (2) Pressure 27 (3) () () See page 12 for How to Read Curves information. 22

@ Catalog HY28-2662-CD/US Dimensional Data Series PAVC 65 INLET PORT 1-7/8-12UN-2B ST. THREAD O-RING SAE-24 OUTLET PORT 1-5/16-12UN-2B ST. THREAD O-RING SAE-16 HP GPM RPM Dimensions Rear Port * Inch equivalents for millimeter dimensions are shown in (**). Notes: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise rotation pump. 2. Pump mounting and shaft comply with SAE C dimensions. 81.3 (3.19) 31.75 (1.25) 88.9 (3.5) 115.82 (4.56) 38.1 (1.5) 88.9 (3.5) SHAFT OPTION OMIT SAE C SHAFT 1-1/4" KEYED MAX. TORQUE = 641 N m (5,68 IN-LBS) 25.4 (1.) 31.75 (1.25) PORT B LOW SIGNAL 7/16-2UNF-2B ST. THREAD O-RING SAE-4 VARIABLE VOLUME PUMP ROTATION CC/REV MAX INITIAL FACTORY SETTINGS BELOW HYDRAULIC PUMP/MOTOR DIVISION Otsego, MI 4978 MADE IN USA VENT/FILL PLUG 11.6 (4.) 9.42 (3.56) 81.3 (3.19) Rear View 11.6 (4.) 9.42 (3.56) 81.3 (3.19) CLEARANCE FOR.625 DIA. MOUNTING BOLTS. SAE C 2-BOLT PATTERN CLEARANCE FOR.5 DIA. BOLTS MOUNTED DIAGONALLY ON SAE C 4-BOLT PATTERN 12.45 (.49) 15.75 (.62) Top View 55.63 (2.19) 31.75 (1.25) TORQUE CONTROL ADJUSTMENT SENSITIVITY: 9 N m (8 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (8 ) PER TURN 224.3 (8.82) 7.925 (.312) WIDE KEY 7.61 (2.78) 52.32 (2.6) 127. (5.) ø 126.94 (4.998) 35.33 (1.391) 35.7 (1.381) ø 31.75 (1.25) 31.69 (1.248) B 5.8 (2.) A 65.28 (2.57) AIRBLEED DRAIN PORT 7/16-2UNF-2B ST. THREAD O-RING SAE-4 35 Front View 115.6 (4.53) 23.37 (.92) PORT A CONTROL DRAIN 9/16-18UNF-2B ST. THREAD O-RING SAE-6 31.75 (1.25) ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITVITY: 13.8 BAR (2 ) PER TURN 63.5 (2.5) 95.25 (3.75) Side View 219.2 (8.63) SHAFT OPTION B 14 TOOTH SAE C SPLINE 12/24 PITCH MAX TORQUE = 641 N m (5,68 IN-LBS) 55.63 (2.19) 83.82 (3.3) MAX OPTION 5 VOLUME STOP SENSITIVITY: 4.2 CC/REV/TURN 27.68 (1.9) MAX OPTION 2 VOLUME STOP SENSITIVITY: 3.8 CC/REV/TURN 23

HP GPM @ RPM Catalog HY28-2662-CD/US Dimensional Data Series PAVC 65 Dimensions Top Port * Inch equivalents for millimeter dimensions are shown in (**). NoteS: 1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls will be on opposite side for a counterclockwise pump. 2. Pump mounting and shaft comply with SAE C dimensions. Port Location Option Outlet Port Inlet Port Control Drain Signal Port 2 SAE-16 Straight Thread (1-5/16-12UNC) OUTLET PORT SEE CHART FOR SIZE 1-1/2 SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 81.3 (3.19) 31.75 (1.25) 192.2 (7.56) SAE-6 Straight Thread (9/16-18UNF) 35.81 (1.41) SAE-4 Straight Thread (7/16-2UNF) INLET PORT SEE CHART FOR SIZE 85.85 (3.38) 115.82 (4.56) 88.9 (3.5) 25.4 (1.) SHAFT OPTION OMIT SAE C SHAFT 1-1/4" KEYED MAX. TORQUE = 641 N m (5,68 IN-LBS) 31.75 (1.25) VARIABLE VOLUME PUMP ROTATION CC/REV MAX INITIAL FACTORY SETTINGS BELOW HYDRAULIC PUMP/MOTOR DIVISION Otsego, MI 4978 MADE IN USA 69.85 (2.75) 11.6 (4.) 9.42 (3.56) 81.2 (3.19) Rear View 11.6 (4.) 9.42 (3.56) 81.2 (3.19) CLEARANCE FOR.625 DIA. MOUNTING BOLTS. SAE C 2-BOLT PATTERN SIGNAL PORT PORT B SEE CHART FOR SIZE CLEARANCE FOR.5 DIA. BOLTS MOUNTED DIAGONALLY ON SAE C 4-BOLT PATTERN 7.925 (.312) WIDE KEY 15.74 (.62) Top View 55.62 (2.19) 12.44 (.49) VENT/FILL PLUG TORQUE CONTROL ADJUSTMENT SENSITIVITY: 9 N m (8 IN-LB) PER TURN PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (8 ) PER TURN 31.75 (1.25) 224.2 (8.82) 7.61 (2.78) 35.33 (1.391) 35.7 (1.381) B 5.8 (2.) 52.32 (2.6) 31.75 (1.25) Ø 31.69 (1.248) 65.27 (2.57) AIRBLEED DRAIN PORT 7/16-2UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8 35 Front View 115.6 (4.53) SHAFT OPTION B 14 TOOTH SAE C SPLINE 12/24 PITCH MAX. TORQUE = 641 N m (5,68 IN-LBS) 23.36 (.92) Ø 127. (5.) 126.94 (4.998) CONTROL DRAIN PORT SEE CHART FOR SIZE ADJUSTABLE DIFFERENTIAL OPTION 4 SENSITIVITY: 13.8 BAR (2 ) PER TURN 55.63 (2.19) 31.75 (1.25) 83.82 (3.3) MAX A 63.5 (2.5) 95.25 (3.75) Side View OPTION 5 VOLUME STOP SENSITIVITY: 4.2 CC/REV/TURN 219.2 (8.63) SECONDARY VENT/FILL 27.68 (1.9) MAX OPTION 2 VOLUME STOP SENSITIVITY: 3.8 CC/REV/TURN 24

Notes Series PAVC 25

Technical Information Series PAVC 1 Performance Information Series PAVC1 Pressure Compensated, Variable Volume, Piston Pump Features High Strength Cast-Iron Housing Built-In Supercharger High Speed Capability - 26 RPM Cartridge Type Controls - Field Changeable Replaceable Bronze Clad Port Plate Airbleed Standard for Quick Priming Hydrodynamic Cylinder Barrel Bearing Full Pressure Rating on Water Glycol Fluids Filtered and/or Cooled Drain Line Capable 7 bar (1 ) Maximum Thru-Shaft Capable Controls Pressure Compensation Remote Pressure Compensation Load Sensing Power (Torque) Limiting Power Limiting and Load Sensing Adjustable Maximum Volume Stop Low Pressure Standby Schematic Symbol (Basic Pump) Weight and Package Size Model Quick Reference Data Chart Pump Model Weight In Kg (Lb) Length From Mounting Face in CM (Inches) Displacement CM 3 /REV (IN 3 /REV) Height in CM (Inches) Pump Delivery @ 21 bar (3 ) in LPM (GPM) Height in CM (Inches) PAVC1 5 (11) 3.73 (12.1) 24.9 (9.82) 21.59 (8.5) Specifications Pressure Ratings: Outlet Port: 27 bar (3 ) Continuous (P1) 248 bar (36 ) Peak (P3) Inlet Port: Control Drain: 1.7 bar (25 ) Maximum.17 bar (5 In. Hg.) Minimum @ 18 RPM (See Inlet Chart for other speeds) 7 bar (1 ) Maximum Speed Ratings: 6 to 26 RPM Operating Temperature Range: 4 C to 71 C ( 4 F to 16 F) Housing Material: Cast-Iron Filtration: Maintain SAE Class 4, ISO 16/13, ISO 18/15 Maximum Recommended Mounting: SAE C 2-Bolt Flange Mount or Diagonally on SAE C 4-Bolt Flange Mount Installation Data: See page A46 of this catalog for specific recommendations pertaining to system cleanliness, fluids, start-up, inlet conditions, shaft alignment, drain line restrictions and other important factors relative to the proper installation and use of these pumps. *Approx. Noise Levels db(a) @ Full 18 RPM (12 RPM) 69 bar (1 ) 138 bar (2 ) 27 bar (3 ) Input Power At 18 RPM, Max. Displacement & 27 bar (3 ) 12 RPM 18 RPM PAVC1 1 (6.1) 119.6 (31.6) 179.8 (47.5) 82 (78) 82 (79) 85 (8) 71.2 kw (95.5 hp) * Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards. 26

Performance Data Series PAVC 1 Typical Performance Data - Fluid: Standard Hydraulic Oil 1 SSU @ 49 C (12 F) Efficiency - % 1 9 8 7 6 LPM 189.3 17.3 151.4 132.5 113.6 94.6 75.7 56.8 37.9 18.9 Bar GPM (5) (45) (4) (35) (3) (25) (2) (15) (1) (5) () () PAVC1 @ 12 RPM 69 (1) Volumetric Efficiency Input Power at Full Overall Efficiency Compensated Power Pressure 138 (2) KW HP 74.6 (1) 27 (3) 67.1 (9) 59.7 (8) 52.2 (7) 44.7 (6) 37.3 (5) 29.8 22.4 14.9 7.5 (4) (3) (2) (1) () Power Efficiency - % 1 9 8 7 6 LPM 189.3 17.3 151.4 132.5 113.6 94.6 75.7 56.8 37.9 18.9 GPM (5) (45) (4) (35) (3) (25) (2) (15) (1) (5) () Bar () PAVC1 @ 18 RPM Overall Efficiency Input Power at Full 69 (1) Volumetric Efficiency Compensated Power Pressure 138 (2) KW HP 74.6 (1) 29.8 22.4 14.9 7.5 27 (3) 67.1 (9) 59.7 (8) 52.2 (7) 44.7 (6) 37.3 (5) (4) (3) (2) (1) () Power NOTE: The efficiencies and data in the graph are good only for pumps running at 18 RPM and stroked to maximum. To calculate approximate input power for the other conditions, use the following formula: [ ] HP = Q x () 1714 + (CHp) Actual GPM is directly proportional to drive speed and maximum volume setting. loss, however, is a function of pressure only. PAVC1 Inlet Characteristics at Full Displacement Inlet Pressure Vacuum bar.41.28.14 (6) (4) (2) bar In-Hg ().17.34.51 (5) (1) (15) (Graph only valid at sea level) Recommended Operating Condition DO NOT OPERATE IN THIS REGION WHERE: Q = Actual Output in GPM = Pressure At Pump Outlet CHp = Input Power @ Full Compensation @ 18 RPM (from graph read at operating pressure) Drain LPM GPM 15.1 (4) 11.3 7.6 3.8 (3) (2) (1) Compensated Control Drain @ 18 RPM.68 (2) 5 1 15 2 26 Shaft Speed - RPM Bar () () 69 (1) 138 (2) System Pressure 27 (3) 27

Performance Data Series PAVC 1 Typical Performance Data - Minimum Power Settings Attainable With Control Options C, H, CM & HM KW (HP) 55.9 (75) PAVC1 27 bar (3 ) Power 44.7 33.6 22.4 11.2 (6) (45) (3) (15) 172 bar (25 ) 138 bar (2 ) Full Boundary 13 bar (15 ) 69 bar (1 ) 34 bar (5 ) NOTE: Minimum attainable HP setting means that input power will not exceed the indicated setting at the indicated RPM and that the pump will achieve full compensator pressure selected. If setting input power limiter below full flow boundary, full flow may not be obtained at low operating pressure. Determine maximum input power limitation at desired RPM. All points above desired compensator setting curve can be achieved. 6 12 18 24 3 Shaft Speed - RPM Power (Torque) Limiting Curves LPM 132.5 GPM (35) PAVC1 @ 12 RPM KW HP 52.2 (7) LPM 189.3 GPM (5) PAVC1 @ 18 RPM KW HP 74.6 (1) 113.6 (3) 44.7 (6) N m In-Lbs 339. (3) 17.3 151.4 (45) (4) 67.1 (9) 59.7 (8) N m In-Lbs 339. (3) 94.6 75.7 56.8 37.9 18.9 (25) (2) (15) (1) (5) 37.3 (5) 29.8 (4) 22.4 3 14.9 (2) 7.5 (1) Input Power 282.5 (25) 226. (2) 169.5 (15) 113. (1) 56.5 (5) Input Torque 132.5 113.6 94.6 75.7 56.8 37.9 18.9 (35) (3) (25) (2) (15) (1) (5) 52.2 (7) 44.7 (6) 37.3 (5) 29.8 (4) Input Power 282.5 (25) 226. (2) 169.5 (15) 22.4 (3) 113. (1) 14.9 (2) 56.5 (5) 7.5 (1) Input Torque () Bar () 69 (1) 138 (2) Pressure 27 (3) () () () Bar () 69 (1) 138 (2) Pressure 27 (3) () () See page 12 for How to Read Curves information. 28

HP GPM @ RPM Catalog HY28-2662-CD/US Dimensional Data Series PAVC 1 Rear Ported Pump Dimensions * Inch equivalents for millimeter dimensions are shown in (**). Note: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side. Outlet Option Omit Inlet Option Omit 3 Omit Port Location Outlet Port Inlet Port Control Drain Signal Port SAE-2 Straight Thread (1-5/8-12UNC) 1-1/4" SAE Flange 7/16-14UNC Thread Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) SAE-6 Straight Thread (9/16-18UNF) SAE-6 Straight Thread (9/16-18UNF) SAE-4 Straight Thread (7/16-2UNF) SAE-4 Straight Thread (7/16-2UNF) Ø 38.1 (1.5) 38.49 (1.498) 55.62 (2.19) SHAFT OPTION B SAE C SPLINE 14 TOOTH 12/24 DP MAX. TORQUE = 639 N m (5,68 IN-LBS) 42.392 (1.669) 42.138 (1.659) 61.97 (2.44) SHAFT OPTION C SAE C-C SHAFT MAX. TORQUE = 1,218 N m (1,78 IN-LBS) SHAFT OPTION D SAE C-C SPLINE 17 TOOTH 12/24 DP MAX. TORQUE = 1,218 N m (1,78 IN-LBS) 17.95 (4.25) 17.95 (4.25) 77.72 (3.6) VENT-FILL/INLET GAUGE PORT 7/16-2UNF-2B STRAIGHT THREAD O-RING OUTLET PORT OPTION OMIT SEE CHART FOR PORT SIZE 139.7 (5.5) 41.4 (1.63) 117.34 (4.62) 141.47 (5.57) 93.21 (3.67) 11.6 (4.) 42.92 (1.69) Ø 5.8 (2.) 28.7 (1.13) 31.75 (1.25) SHAFT OPTION OMIT SAE C SHAFT MAX. TORQUE = 639 N m (5,68 IN-LBS) VARIABLE VOLUME PUMP Rotation cc/rev max INITIAL FACTORY SETTINGS BELOW Fluidpower Pump Division Otsego, Mich. 4978 USA REAR INLET PORT (INLET PORT OPTION OMIT ) SEE CHART FOR PORT SIZE PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (8 ) PER REV TORQUE CONTROL ADJUSTMENT (CONTROL OPTIONS C,H,CM & HM) SENSITIVITY: 13 N m (1,15 IN-LBS) PER REV. Rear View Top View 29

Dimensional Data Series PAVC 1 Rear Ported Pump Dimensions * Inch equivalents for millimeter dimensions are shown in (**). Note: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side. Ø31.75 (1.25) 28.7 (1.13) 41.4 (1.63) OPTION 3 OUTLET PORT (SEE CHART ON PAGE A166 FOR PORT SIZE) 58.67 (2.31) 3.22 (1.19) Option 3 Outlet Port ADAPTABLE TO SAE C 2-BOLT MOUNTING OR DIAGONALLY ON SAE C 4-BOLT MOUNTING OUTLET PRESSURE GAUGE PORT 7/16-2UNF-2B STRAIGHT THREAD O-RING 91.94 (3.62) 74.67 (2.94) 7.11 R (.28) 9.42 (3.56) 81.2 (3.19) 9.42 (3.56) 81.2 (3.19) PORT B SIGNAL STRAIGHT THREAD O-RING SEE CHART ON A166 FOR PORT SIZE 7.925 (.312) WIDE KEY 35.33 (1.391) 35.7 (1.381) 127. (5.) Ø 126.94 (4.998) 31.75 (1.25) Ø31.69 (1.248) 55.62 (2.19) 12.44 (.49) 33.53 (11.95) ROTATION ARROW 158.49 (6.24) 112.77 (4.44) AIRBLEED DRAIN PORT 7/16-2UNF-2B ST. THREAD O-RING SAE-4 36.32 (1.43) Front View 114.3 (4.5) MAX PORT A CONTROL STRAIGHT THREAD O-RING SEE CHART ON A166 FOR PORT SIZE OPTION 4 DIFFERENTIAL PRESSURE ADJUSTMENT 28 BAR (4 ) PER REV. 73.15 (2.88) 14.9 (4.13) 41.4 (1.63) OPTION 2 MAX. VOLUME ADJUSTMENT SENSITIVITY: 5CC/REV/REV OPTION 5 MAX. VOLUME ADJUSTMENT SENSITIVITY: 5.6CC/REV/REV Side View 2.54 (.1) MAX 55.88 (2.2) MAX 3

HP GPM @ RPM Catalog HY28-2662-CD/US Dimensional Data Series PAVC 1 Top/Bottom Ported Pump Dimensions * Inch equivalents for millimeter dimensions are shown in (**). Notes: 1. Pump shown and dimensioned is a clockwise rotation top/ bottom inlet option pump. For a counterclockwise rotation pump the outlet port, control drain, signal port, and pump controls will be on other side. 2. For other available shafts see page A34. 114.3 (4.5) 93.21 (3.67) 159.25 (6.27) 11.6 (4.) 138.43 (5.45) ADAPTABLE TO SAE C 2-BOLT MOUNTING OR DIAGONALLY ON SAE C 4-BOLT MOUNTING OUTLET PRESSURE GAUGE PORT 7/16-2UNF-2B ST. THREAD O-RING R7.11 (.28) 91.94 (3.62) 17.95 (4.25) Rear View 9.42 (3.56) 81.2 (3.19) 17.95 (4.25) 9.42 (3.56) 81.2 (3.19) VENT-FILL/INLET GAUGE PORT 7/16-2UNF-2B STRAIGHT THREAD O-RING THREADED OURTLET PORT OUTLET PORT OPTION OMIT SEE CHART A169 FOR PORT SIZE 28.7 (1.13) SHAFT OPTION OMIT SAE C SHAFT MAX. TORQUE = 639 N m (5,68 IN-LBS) 31.75 (1.25) PRESSURE COMPENSATOR ADJUSTMENT SENSITIVITY: 55 BAR (8 ) PER REV SIGNAL PORTS PORT B SEE CHART, A169 FOR PORT SIZE 55.62 (2.19) 7.925 (.312) WIDE KEY 35.33 (1.391) 35.7 (1.381) Top View 244.34 (9.62) 139.7 (TOP PORT) (5.5) 41.4 (1.63) 12.44 (.49) VARIABLE VOLUME PUMP Rotation cc/rev max INITIAL FACTORY SETTINGS BELOW Hydraulics Pump Division Otsego, Mich. 4978 USA 31.13 (12.21) ROTATION ARROW OPTION 2 INLET PORT FLANGE INLET PORT SEE CHART A169 FOR PORT SIZE BOTTOM PORT OPPOSITE SIDE SAME PATTERN ROTATED 9 159.49 (6.24) 42.92 (1.69) ø5.8 (2.) 77.72 (3.6) TORQUE CONTROL ADJUSTMENT (CONTROL OPTIONS C,H,CM & HM) SENSITIVITY: 13 N m (1,15 IN-LB) PER REV. 74.67 (2.94) ø 31.75 (1.25) 31.69 (1.248) 112.77 (4.44) AIRBLEED DRAIN PORT 7/16-2UNF-2B ST. THREAD O-RING SAE-4 OPTION 8 ISO 6149-4 ADAPTER FITTING ON OPTION 8 Front View 114.3 (4.5) MAX 127. (5.) ø 126.94 (4.998) 36.32 (1.43) CONTROL DRAIN PORT A SEE CHART, A169 FOR PORT SIZE 41.4 (1.63) OPTION 4 DIFFERENTIAL PRESSURE ADJUSTMENT 28 BAR (4 ) PER REV 73.15 (2.88) 14.9 (4.13) BOTTOM INLET PORT 237.99 (9.37) (BOTTOM PORT) Side View OPTION 2 MAX. VOLUME ADJUSTMENT 5CC/REV/REV 49.53 (1.95) MAX. OPTION 5 MAX. VOLUME ADJUSTMENT 5.6CC/REV/REV 31

Dimensional Data Series PAVC 1 Top/Bottom Ported Pump Dimensions * Inch equivalents for millimeter dimensions are shown in (**). Note: Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain, signal port and pump controls will be on other side. Outlet Option Inlet Option Omit 2 3 2 Port Location Outlet Port Inlet Port Control Drain Signal Port SAE-2 Straight Thread (1-5/8-12UN) 1-1/4" SAE Flange 7/16-14UNC Thread Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) 2" SAE 4-Bolt Flange 1/2-13UNC Threads Standard Pressure Series (Code 61) SAE-6 Straight Thread (9/16-18UNF) SAE-6 Straight Thread (9/16-18UNF) SAE-4 Straight Thread (7/16-2UNF) SAE-4 Straight Thread (7/16-2UNF) Dimensions Thru-Shaft Options * Inch equivalents for millimeter dimensions are shown in (**). Variation 6A4 Ø 82.58/82.6 (3.251/3.252) 16.38 (4.188) N/A 3/8-16UNC-2B N/A 9 Tooth 16/32 Pitch N/A 6B3 53.98 (2.125) Ø 11.63/11.65 (4.1/4.2) 146.5 (5.75) 89.81 (3.536) 1/2-13UNC-2B 1/2-13UNC-2B 13 Tooth 16/32 Pitch N/A 6B4 53.98 (2.125) Ø 11.63/11.65 (4.1/4.2) 146.5 (5.75) 89.81 (3.536) 1/2-13UNC-2B 1/2-13UNC-2B 15 Tooth 16/32 Pitch N/A 6C3 53.98 (2.125) Ø 127.3/127.5 (5.1/5.2) 18.98 (7.125) 114.5 (4.58) 5/8-11UNC-2B 1/2-13UNC-2B 14 Tooth 12/24 Pitch N/A 32

Dimensional Data Series PAVC 1 Thru-Shaft Options Dimensions * Inch equivalents for millimeter dimensions are shown in (**). Notes: 1. Rear adapters may be rotated 9. 2. Pump shown is a clockwise rotation pump. For a counterclockwise pump the outlet port, control drain and control adjustments will be on opposite side. 3. Maximum torque transmitting capacity for rear mounting of pumps is 639 N m (5,68 In. Lbs). Lower allowables may apply based on pump mounted on rear. 299.72 (11.8) A C 2 C E G Side View Rear View Variations 6A* & 9A* C 2 C H B D 2 D G E F D 2 D Rear View Variations 6B* & 6C* 9B* & 9C* 33

Installation Information Series PAVC 33/38/65/1 Generic Pump Assembly MAX VOL. STOP VARIATION - 5 1 95 N m (7 FT. LBS.) TORQUE MAX VOL. STOP VARIATION - 2 23 N m (17 FT. LBS.) TORQUE 4 1 TRUNNION CAP ASSEMBLY 4 RETAINER DETAIL 7 AIR BLEED ASSEMBLY THRUST WASHER (Not on PAVC1) SNAP RING O-RING TRUNNION CAP ROLLER BEARING 2 SLEEVE ASSEMBLY 5 BEARING SHAFT ASSEMBLY BODY SPRING BALL 8 STAKE BALL IN PLACE ADJUSTING STEM ASSEMBLY SLEEVE O-RING 1 BACK-UP RING 1 2 2 1 2 2 1 PLUG STEM O-RING 1 BACK-UP RING 1 2 1 1 2 2 9 PORT PLATE 3 PLUG ASSEMBLY SLEEVE 1 2 O-RING 1 BACK-UP RING 2 6 PISTON - DIFFERENTIAL CONTROL PISTON BODY O-RING 1 BACK-UP RING 2 1 2 LEFT HAND (CCW) PORT PLATE SHOWN IN ASSEMBLY (ABOVE). RIGHT HAND (CW) PORT PLATE SHOWN BELOW. 34

Installation Information Series PAVC 33/38/65/1 169 N m (125 FT. LBS.) TORQUE 13.5 N m (1 FT. LBS.) TORQUE 76 THESE ITEMS ARE SHOWN IN POSITION FOR CONTROL OPTION OMIT. SEE SEPARATE DIAGRAM FOR OTHER CONTROL OPTIONS. 5 7 2 18 N m (8 FT. LBS.) TORQUE 6 ADJUSTABLE DIFFERENTIAL VARIATION - 4 5 9 4 3 POSITION POSITION 1 TORQUE (HP) CONTROL (See next page) Part Number Description 12 x 1 Solid Pipe Plug (1/16") 18 x 4 SAE Plug - 4 6987.28 Orifice Plug (1/16") 8599.34 Orifice Plug (1/16") 786635.34 Orifice Fitting 787474 Upstroke Spring 2 1 3 PAVC 33, 38, 65 8 27 N m (2 FT. LBS.) TORQUE 68 N m (5 FT. LBS.) TORQUE NON-ADJUSTABLE DIFFERENTIAL VARIATION - OMIT Position Control Option Omit Open 8599 18 x 4 18 x 4 Omit A 12 x 1 8599 Open 18 x 4 787474* C 12 x 1 8599 Open 18 x 4 787474* H Open 8599 18 x 4 18 x 4 Omit M 8599 Open Open 18 x 4 Omit ME 12 x 1 8599 Open 18 x 4 787474* S 8599 Open Open 18 x 4 Omit SE 12 x 1 8599 Open 18 x 4 Omit AM 12 x 1 8599 786635 Open 787474* CM 12 x 1 8599 786635 Open 787474* HM 8599 Open Open 18 x 4 Omit * Available Only on PAVC65. PAVC 1 Position Control Option Omit Open 6987 18 x 4 18 x 4 787474 A 12 x 1 6987 Open 18 x 4 787474 C 12 x 1 6987 Open 18 x 4 787474 H Open 6987 18 x 4 18 x 4 787474 M 6987 Open Open 18 x 4 787474 ME 12 x 1 6987 Open 18 x 4 787474 S 6987 Open Open 18 x 4 787474 SE 12 x 1 6987 Open 18 x 4 787474 AM 12 x 1 6987 786635 Open 787474 CM 12 x 1 6987 786635 Open 787474 HM 6987 Open Open 18 x 4 787474 787474 is always included with the PAVC1. 35

Installation Information Series PAVC 33/38/65/1 1 CONTROL OPTION C & H PRESSURE, POWER & FLOW 1-32UNF-2B OMIT 27 N m (2 FT.-LBS.) TORQUE 14 N m (1 FT.-LBS.) TORQUE SET @ MAX. PRESSURE PER TEST SPEC. THEN INSTALL JAM NUT, LOCKING NUT AND LOCKING TAB. ADD 36

Installation Information Series PAVC 33/38/65/1 Use Of A Relief Valve The use of a relief valve, while not mandatory is recommended in the main circuit to suppress hydraulic shock loads and additional system protection. If a minimum volume stop is used, the use of a relief valve is mandatory. Fluid Recommendations Premium quality hydraulic oil with a viscosity range between 15-25 SSU (3-5 cst.) at 38 C (1 F). Normal operating viscosity range between 8-1 SSU (17-18 cst.). Maximum start-up viscosity is 4 SSU (1 cst.). Note: Consult Parker when exceeding 71 C (16 F) operation. Oil should have maximum anti-wear properties, rust and oxidation treatment. Filtration For maximum pump and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 1 microns per milliliter of fluid. (SAE Class 4/ISO 16/13). Due to the nature of variable displacement pumps, variations in pump inlet conditions, fluid acceleration losses, system aeration, and duty cycle we do not recommend suction line filters. We do recommend the use of a properly sized, in-tank suction strainer. Contact your Parker representative for assistance. Start-Up On initial start-up, the case should be filled with oil, pressure should be reduced and the circuit should be open or the air bled from the pump outlet to permit priming. Use of the airbleed is recommended on initial start-up. See Installation and Mounting Section to connect airbleed. Inlet Conditions Not to exceed.17 bar (5 In. Hg.). Vacuum at 18 RPM on petroleum base fluids. See recommended speed spectrum for specific inlet conditions. Shaft Rotation and Line Up Pump and motor shaft alignment must be within.1 TIR maximum, using a standard floating coupling. Please follow coupling manufacturer s recommended installation instructions to prevent end thrust on pump shaft. Turn pump to assure freedom of rotation. Pump and motor must be on a rigid base. The coupling should be sized to absorb the peak horsepower developed. Installation and Mounting When a PAVC Series Pump is mounted above the fluid level, the position of the control drain is not restricted but the inlet port should not be on the bottom (PAVC1). When a PAVC Series Pump is mounted below the fluid level the position of all ports are not restricted. The control drain should be a separate line to the reservoir and extend below the oil level as far from the inlet line as possible. The control drain line can be filtered and/or cooled (must not exceed 7 bar (1 ) back pressure). Suggested maximum line length is 1 feet. A built in airbleed is standard on all PAVC 33, 38, 65 and 1 Pumps. To connect, remove airbleed drain plug and connect a line unrestricted to reservoir extending below minimum oil level. Back pressure in this line must not exceed.28 bar (4 ). Special Installations Consult your Parker representative for any application requiring the following: Pressure above rated, drive speed above maximum, indirect drive, fluid other than petroleum oil, oil temperature above 71 C (16 F). Inlet Pressure Not to exceed 1.72 bar (25 ). 37