Pressure transmitters for heavy duty applications Type MBS 3250

Similar documents
Pressure transmitters for heavy duty applications MBS 3200 and 3250

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Pressure transmitter for marine applications MBS 33M

Pressure transmitters for industrial applications Type MBS 4510

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Pressure transmitter for industrial applications Type MBS 4510

MBS 1200 and MBS 1250

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Pressure transmitter for air and water applications Type MBS 1900

CTE8000 / CTU8000 Series

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

JUMO MIDAS S05 Pressure transmitter Type

M5200 Industrial Pressure Transducer

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

EPI Applications. Features

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

Electronic Pressure Switches

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Adjustment range. Seal material. Pressure connection

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Heavy duty pressure switch MBC 5000 and MBC 5100

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Electronic Pressure Switches

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

SATRON VTe pressure transmitter

Paddle-wheel flow controller for On/Off control

INSERTION flow sensor for continuous flow measurement

Paddle-wheel flow controller for On/Off control

OEM Pressure Transmitters

Marine Pressure ECTN Applications. Features

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

Temperature Sensor MBT 3270

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

CTE7000 / CTU7000 Series Miniature pressure transmitters

Seal material. Pressure range. Pressure connection -40 F +212 F 1 -4 F +257 F 3

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Electronic Pressure Switches

ECT Applications. Features

OEM Pressure Transmitters

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Pressure Transmitters

Temperature Sensor MBT Technical brochure

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

SATRON VDt Differential Pressure Transmitter

Industrial Pressure Transmitters

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Condensed Catalog 2006 North America

SATRON VVFe Pressure Transmitter

Industrial Pressure Transmitter

SBM TECHNOLOGY PET Blow Valve Block

Paddle-wheel flow controller with optical principle for On/Off control

Pressure transducer DMU 01K Compact version

Pressure Precision. Description. Features. Measuring ranges. Applications. with front-flush diaphragm for gauge pressure and absolute pressure

EPN/EPNCR Applications. Features

FPT Applications. Features

Temperature sensors types MBT 153, MBT 120 and MBT 3260

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

SATRON VT Pressure Transmitter

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Electronic Pressure Switches

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

INSERTION flowmeter with paddle wheel, ELEMENT design

G 1/4 A DIN 3852 (bar version) ±0.5 %FS max

SPT- I / U PRESSURE TRANSMITTER for general applications

Solenoid valves 2/2-way servo operated type EV220B 15 50

CONTINENTAL HYDRAULICS VED03MX

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Temperature sensor Type MBT 3270

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

Accessories & spare parts - pressure transmitters

Servo-operated 2/2-way solenoid valves Type EV220A

Features. Available with 0,5-4,5Vdc output. Operating from -40 to +140 C. Designed for harsh environment. Large Bandwidth

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

Differential Pressure Sensors

SSI Technologies MediaSensor

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

JUMO MIDAS Pressure transmitter

Transcription:

Pressure transmitters for heavy duty applications Type MBS 3250

Features Designed for use in harsh industrial environments For medium and ambient temperatures up to 125 C With integrated pulse-snubber. Protected against cavitation, liquid hammering and pressure peaks All standard output signals: 4-20 ma, 0-5 V, 1-5 V, 1-6 V, 0-10 V Enclosure and wetted parts of AISI 316L A wide range of pressure and electrical connections Temperature compensated, linearized and laser adjusted Description The compact heavy duty pressure transmitter MBS 3250 with integrated pulse-snubber is designed for use in hydraulic applications with severe medium influences like cavitation, liquid hammer or pressure peaks and offers a reliable pressure measurement, even under harsh environmental conditions. The flexible pressure transmitter programme covers different output signals, absolute and gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar and a wide range of pressure and electrical connections. A robust design, an excellent vibration stability and a high degree of EMC/EMI protection equip the pressure transmitter to meet the most stringent industrial requirements. Ordering standard versions Output: 4-20mA Pressure connection : DIN 3852-E-G¼ Plug: EN 175301-803-A,Pg 9 Measuring range Pe [bar] Overload pressure (Static) [bar] Burst pressure Pe [bar] 0-1.6 12 100 MBS 3250-1211-1GB04-1 060G1860 0-2.5 24 100 MBS 3250-1411-1GB04-1 060G1861 0-4 24 100 MBS 3250-1611-1GB04-1 060G1862 0-6 60 100 MBS 3250-1811-1GB04-1 060G1863 0-10 60 100 MBS 3250-2011-1GB04-1 060G1791 0-16 150 150 MBS 3250-2211-1GB04-1 060G1864 0-25 150 150 MBS 3250-2411-1GB04-1 060G1865 0-40 300 400 MBS 3250-2611-1GB04-1 060G1790 0-60 360 800 MBS 3250-2811-1GB04-1 060G1866 0-100 600 1200 MBS 3250-3011-1GB04-1 060G1867 0-160 1200 1200 MBS 3250-3211-1GB04-1 060G1868 0-250 1500 2000 MBS 3250-3411-1GB04-1 060G1779 0-400 1500 2000 MBS 3250-3611-1GB04-1 060G1869 0-600 1500 2000 MBS 3250-3811-1GB04-1 060G1778 Type Code no. 2

Technical data Performance (EN 60770) Accuracy (incl. non-linearity, hysteresis and repeatability) Non-linearity (best fit straight line) Hysteresis and repeatability Thermal error band (compensated temperature range) Liquids with viscosity < 100 cst Response time Air and gases Overload pressure (static) Burst pressure Durability, P: 10-90% FS ±0.5% FS (typ.) ±1% FS (max.) ±0.2% FS ±0.1% FS ±1% FS < 4 ms < 35 ms Min. 6 FS (max. 1500 bar) >6xFS (max. 2000 bar) >10 106 cycles Electrical specifications U B Nom. output signal (short-circuit protected) 4-20 ma 0-5, 1-5, 1-6 V d.c 0-10 V, 1-10 V d.c. Supply voltage [U B], polarity protected 9-32 V d.c. 10-30 V d.c. 15-30 V d.c. Supply current consumption 5 ma 8 ma Supply voltage dependency ±0.05% FS/10 V Current limitation 28 ma (typ.) Output impedance 25 Ω Load [R L ] (load connected to 0 V) R L (U B -9 V)/0.02 A R L 10 ka R L 15 ka Environmental conditions Media temperature range (depending on gasket material) -40 - +125 C Ambient temperature range (depending on electrical connection) see page 5 Compensated temperature range 0 - +100 C Transport temperature range 50 - +125 C EMC Emission EN 61000-6-3 EMC Immunity EN 61000-6-2 Insulation resistance > 100 Mohm at 100 V d.c Mains frequency test SEN 361503 15.9 mm-pp, 5 Hz-25 Hz Sinusoidal Vibration stability 20 g, 25 Hz-2 khz IEC 60068-2-6 Shock resistance Random Shock Free fall 7.5 grms, 5 Hz-1 khz 500 g/1 ms IEC 60068-2-64 IEC 60068-2-27 IEC 60068-2-32 Enclosure (depending on electrical connection) see page 5 Mechanical conditions Wetted parts EN 10088-1 ; 1.4404 (AISI316L) Materials Enclosure EN 10088-1 ; 1.4404 (AISI316L) Pressure connection see page 4 Electrical connections see page 5 Weight (depending on pressure connection and electrical connection) 0.2-0.3 kg Application and media conditions Pulsesnubber Application Cavitation, liquid hammer and pressure peaks may occur in liquid filled hydraulic systems with changes in flow velocity, e.g. fast closing of a valve or pump starts and stops. The problem may occur on the inlet and outlet side, even at rather low operating pressures. Media condition Clogging of the nozzle may occur in liquids containing particles. Mounting the transmitter in an upright position minimizes the risk of clogging, because the flow in the nozzle is restricted to the start-up period when the dead volume behind the nozzle fills, and furthermore because the nozzle orifice is relatively big (0.3 mm). The media viscosity has only little effect on the response time. Even at a viscosities up to 100 cst, the response time will not exceed 4 ms. 3

Ordering MBS 3250 - - - Measuring range 0-1 bar... 1 0 0-1.6 bar... 1 2 0-2.5 bar... 1 4 0-4 bar... 1 6 0-6 bar... 1 8 0-10 bar... 2 0 0-16 bar... 2 2 0-25 bar... 2 4 0-40 bar... 2 6 0-60 bar... 2 8 0-100 bar... 3 0 0-160 bar... 3 2 0-250 bar... 3 4 0-400 bar... 3 6 0-600 bar... 3 8 Gasket/O-ring material 0... No gaskes (see pressure connections) 1... Viton (media temp.: -20 to +125 C) Pressure connection A B 0 8... G½ A (EN 837), excl. gasket A C 0 4... ¼ 18 NPT, excl. gasket F A 0 9... DIN 3852-E-M14 1.5, gasket: DIN 3869-14 G A 1 2... DIN 3852-A-M18 1.5, excl. gasket G B 0 4... DIN 3852-E-G¼, gasket: DIN 3869-14 Electrical connection 1... Plug EN175301-803-A, Pg 9 2... *)Plug, AMP Econoseal, J series, male, excl. female plug 3... Screened cable, 2 m 5... *)Plug, IEC 60947-5-2, M12 1, male, excl. female plug 8... *) Plug, AMP Superseal 1.5 series male, excl. female plug Pressure reference Gauge (relative)... 1 Absolute... 2 * Gauge versions only available as sealed gauge versions Output signal 4-20 ma 1 0-5 V 2 1-5 V 3 1-6 V 4 0-10 V 5 Preferred versions Non-standard build-up combinations may be selected. However, minimum order quantities may apply. Please contact your local Danfoss office for further information or for request on other versions. Dimensions/Combinations Type Code 1 2 3 5 8 EN175301-803-A, Pg 9 AMP Econoseal 2 m screened cable EN 60947-5 - 2 4-pin; M12 x 1 AMP Superseal G ½ A (EN 837) ¼ 18 NPT DIN 3852-E-M14 1.5 Gasket: DIN 3869-14-NBR DIN 3852-A-M18 1.5, excl. gasket DIN 3852-E-G ¼ Gasket: DIN 3869-14-NBR Type Code AB08 AC04 FA09 GA12 GB04 Recommended torque 1) 30-35 Nm 2-3 turns after finger tightened 1)Depends of different parameters as packing material, mating material, thread lubrication and pressure level. 30-35 Nm 30-35 Nm 30-35 Nm 4

Electrical connections Type code page 4 1 2 3 5 8 EN 175301-803-A, Pg 9 AMP Econoseal J series (male) 2 m screened cable IEC 60947-5-2 4-pin; M12 x 1 AMP Superseal 1.5 series (male) Ambient temperature, 4-20 ma output -40 to +100 C -40 to +100 C -30 to +85 C -25 to +90 C -40 to +100 C Ambient temperature, 0-5 V, 1-5 V, 1-6 V and 0-10 V output -40 to +125 C -40 to +105 C -30 to +85 C -25 to +90 C -40 to +125 C Enclosure (IP protection fulfilled together with mating connector) Materials IP 65 IP 67 IP 67 IP 67 IP 67 Glass filled polyamid, PA 6.6 Glass filled polyamid, PA 6.6 1) Electrical connection, 4-20 ma output (2 wire) Earth: Connected to MBS enclosure Electrical connection, 0-5 V, 1-5 V, 1-6 V, 0-10 V output Earth: Connected to MBS enclosure Polyolifin cable with PE shrinkage tubing Brown wire: +supply Black wire: supply Red wire: Not used Orange: Not used Screen: Not connected to MBS enclosure Brown wire: Output Black wire: supply Red wire: + supply Orange: Not used Screen: Not connected to MBS enclosure Nickel plated brass, CuZn/Ni Pin 2: Not used Pin 4: supply Pin 2: not used Pin 4: supply Glass filled polyamid, PA 6.6 2) 1) Female plug: Glass filled polyester, PBT 2) Wire: PETFE (teflon) Protection sleeve: PBT mesh (polyester) 5

6 Danfoss A/S 04-2009 DE-BD