Sacred Sun World Wide

Similar documents
GFM-C Series >>> 03 Page. 02 Page SACRED SUN SACRED SUN

GEL Technology

Modular Max AGM Range VRLA

OPzV Batteries. Technical Data

Tubular Gel Technology For Solar Applications

SPA AGM VRLA batteries

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

OPzV Batteries for Stationary Applications

Tubular Gel (OPzV) Batteries. Stationary & Renewable Energy Applications

2 Volt AGM Range. Haze Battery Company Ltd

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

RES OPzV Premium Quality Batteries. for Renewable Energy Storage

FAT. FAT Battery Range FIAMM.COM

STANDBY POWER SOLUTIONS

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

Deep Cycle AGM Range VRLA

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Applications. EMC tested

Haze Battery Company Ltd

OPzV Batteries. for Stationary Applications

OPzV Batteries. for Stationary Applications

Narada + Partners Solution

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. Gelled Electrolyte Range. Monobloc

Tubular Flooded (OPzS) Batteries

Reserve Power OPzV Batteries

Reserve Power OPzV Batteries

Haze Battery Company Ltd

VRLA gel battery. power the future

Features and Benefits

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Power to keep you on the move

6 & 12 Volt Monobloc GEL Range

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

1 2 V F T A S E R I E S

SECTION TECHNOLOGIES I NDUSTRIAL E NERGY

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM

[Charge] [Lead dioxide] [Lead] [Sulfuric acid] [Lead sulfate] [Lead sulfate] [Water]

Haze Battery Company Ltd

SECTION

Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION

Batery SERIES. VALVE REGULATED LEAD ACID BATTERies INFINITE POWER. Mission Critical Applications. All Battery Range

PowerStor Standby Battery Systems

Battery Solutions. Presented by Wouter Vink Business Development Manager Enersys Powertech Reserve Power / DC Power Solutions

6 & 12 Volt Monobloc. Haze Battery Company Ltd

SECTION A Division of Exide Technologies

General Catalogue VRLA-AGM, VRLA-GEL and Stationary Batteries

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

Sealed Lead Acid Battery STANDBY APPLICATIONS. Premium Brand of Flying Power Group. Certified by

Sealed Rechargeable VRLA Batteries

SECTION

Tubular Flooded (OPzS) Batteries

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

SECTION

SECTION A Division of Exide Technologies

CELLYTE 12 PLF & 12PLT Range

SEC. MICROLYTE +Plus. Industrial Battery Co. Supplied Worldwide by: Visit our website on Features. Application

list in Sealed Lead Acid ( SLA )batteries from Japan more than 150,000 units of batteries every month on

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Pure Lead-Tin Technology

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

ENERGY STORAGE SOLUTIONS

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

Narada high temp. battery

PHOTOVOLTAIC BATTERIES

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

Batteries for Renewable Energy Applications

V R L A HI-PERFORMANCE BATTERIES

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

Company Introduction. Established: YEARS. Investment: More than 30 million US Dollar. Factory Area: 220,000 square meter.

RENEWABLE BROCHURE. World Class Battery Engineering Flooded & AGM Batteries

Power You Can Depend. C&D Proprietary Information

Standby Products SD-SDH. series. Technical Features. Applications. Product Features

Industrial Batteries / Network Power. Sonnenschein A400 FT.»The dryfit range for modular performance adaption«

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies

Industrial Batteries / Network Power. Sonnenschein A600.»Premium quality for uninterrupted communication«

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

ENERGY STORAGE SOLUTIONS

EcoSafe EOPzV. Operation Guide for Solar Applications

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

PRODOCOM COMPANY PRESENTATION. About Prodocom. Resources. Markets. Products. Customers. Overview Vision and Mission Strategy Work Values

PS-Series General Purpose Batteries

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION?

FIAMM. stationary batteries J^^^^^^^IRP^ FIAMM

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

BAE SECURA Product Programme Stationary Batteries ENERGY FROM BATTERIES BAE

Maintenance Free Sealed Lead Acid Batteries

Industrial Batteries - Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications

Industrial Batteries / Network Power. Classic OCSM.»Exceptional combination of high power, long life and excellent cycling capability«

Headquarters Add: 10th Floor, Tower C, 1st Building, Software Industry Base, No.81, Xuefu Road, Nanshan District, Shenzhen, Guangdong, China

SVTX AGM VRLA batteries

Prepared for 7 x 24 Exchange

Reserve Power Systems

Battery Performance Specifications

INTRODUCING THE LEAD CRYSTAL BATTERY

OPERATION MANUAL. GFM-Series. Storage Battery Systems, Inc. N56 W16665 Ridgewood Dr. Menomonee Falls, WI (262)

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage«

Renewable Energy Storage Solutions

VRLA Battery. Battery Construction. Top lid Safety valve (under the Top lid) Terminal. Cover

Transcription:

Sacred Sun World Wide Our sales growth is due to a complete networks with master distributors through serving global key accounts locally, and regional loyalty sales representative who fully accepted and understood our philosophy and strategy to fulfill Sacred Sun Globalization. SHANDONG SACRED SUN POWER SOURCES CO.,LTD Add: No.1 Shengyang Road, Qufu 273100 China Tel: +86-537-4438666-6028 Fax:+86-537-4411980 Website: www.sacredsun.com E-mail: sales@sacredsun.cn

Company Introduction...02 Quality Control...04 Specification and Applications...06 SP series...08 SPG series...10 FT series... GFM-C series...14 GFMG series...16 GFM-H series...18 GFMU-C series...20 HTB series...22 SAJ series...24 SDC series...26 FTJ series...28 FMJ series...30 GFMJ series...32 OPzV series...34 FCP series...36 PzB/PzS series...38 DM series...42...44

COMPANY INTRODUCTION Our Divisions: Reserve Power Motive Power Lithium Ion System Integration Shandong Sacred Sun Power Sources Co.,Ltd is a global leader in designing, manufacturing and deploying an innovative range of batteries for reserve power and motive power,site solution and system integration as well. Shandong Sacred Sun Power Sources Co. ltd is a national high and new technology enterprise founded in 1991 and listed on the SME board of the Shenzhen Stock Exchange in May of 2011. The company is manufacturing different VRLA batteries AGM and Gel (Ogiv and Opzv) technologies For 2/6/ Volts and from capacity 6.5ah to 3000Ah. Sacred Sun products are designed to be high power, long life and premium quality, also innovative products like high temperature Battery for extreme applications and Lead Carbon Battery which are super long life and high cycling performances The Company is a more modern factory of 200,000 square meters with more advance equipments like Sovema Mills, Wirtz Casting Machines and Hadi Automatic Tubular Plates Production Lines. The current production capacity is 6Mio KVAh per year. The company employs over 2000 people with a Global presence. Markets Segments into Telecommunication,UPS,Energy,Renewable Energy, Transport, Motive Power. Mission and Vision To Become a Market Leadership We are committed to provide energy supply with products and services in a smarter, simpler and more cost effective manner. The product offer must provide the customer complete satisfaction with: Creativity and lnnovative Technology; Products adapted to customer requirement; High quality products and services; Efficient and global supply chain. Our Value SACRED SUN Is loyalty, persistence, striving, dedication Our value is Stand with Morality, Honesty and Dedication, Teamwork First and Pursue Excellence. Business mode focus on Customer First, Value Added with: Reasonable price; Reliable quality; Prompt delivery; Good service. 02 03

Quality assurance and quality management system Design and develop products according to market and customer s requirements and expectation. Reach agreement with the customer s specification and quality standards. Our objective is to reach premium design and quality Factories are supported with 0 skilled people of quality department examinations, verifications, from raw materials inspection to finished products, in order to suggest improvement and follow corrective actions. Sacred Sun has also implemented systems like PDCA, ERP, Bar Code and 6S. In order to help and improve the process on an ongoing basis. Manufacturing Modern Equipments and Facilities Sovema 24 tons ball mill machine, five Sanhuan 24 tons miller, Mixter, Pasting Machines; Barton tons ball mill machine Mac Pasting Machines; Four Wirtz 40 C grid casting machine, thirty-seven units grid casting machine domestic; Automatic assembly line from plates to finished products; Heat sealing machine; Digatron charger and discharger; Hadi plate manufacturing line for tubular gel battery; Research and Development Highly quality R&D team among SLA manufacture; Fully equiped with computerized lab equipment; Specialized in product design and benchmark competitor analysis; Continuously developing new models and new technology; More than 130 national patent; More than 100 R&D engineer; Annual R&D budget 1 million USD; Member of ALABC, National lead acid battery standard committee of China; CNAS testing center Major test equipments: High/low temperature test cabinets; Mechanical vibration test stand; Ion chromatograph; Laser particle size distribution instrument; Atomic absorption spectrophotometer High/low rate discharger imported from American Bitrode company; Cycle life testing machine imported form American Bitrode company; Direct-reading Spectrometer improted from Swiss ARL company; Environment and Employee Health Care Environment policy Adherence to law, production without pollution, energy saving and continous improvement. We pay attention to environment protection and taking care of employees security. We are environment friendly production, and satisfy national standards of environment. Donaldson dust catcher; Lead mist catcher; Desulfurizing catcher. The dusting and purifying system, absorption and purification lead dust in the air. S e w a g e d i s p o s a l system, collection and purification sewage 04 05

LEAD ACID BATTERY SACREN SUN BATTERY PRODUCTS Specifications vs Applications With a wide range of 2 volts single cell and 6/8/ volts monoblocs with capacity from 6.5Ah to 3000Ah; For the major applications such as Telecommunications, UPS, Alarms, Security, Power plant. Renewable Energy; Transportation, EV and other applications which require back-up power system to safeguard power security and input current. AGM GEL Lead Carbon E-TREK SP SPG FT GFM-C GFMG GFM-H GFMU-C HTB SAJ SDC FTJ FMJ GFMJ OPzV FCP DM Specifications Applications Telecom UPS,Data Center Emergency Security, Alarms Renewable Energy Energy Mobility Transportation Medical Universal of Plates Technology Monoblocs 2 Volts Cell Eurobat Classification Design Life (years,25 ) Capacity Range (Ah) X XX XX XX XX XX X X XX XX XX XX X X XX XX X XX XX XX X XX X X X X X X XX XX X X XX X X X X X X XX XX XX XX X XX XX XX XX X X X X XX X XX X XX X XX X X X X X XX XX X X X X X X X X X X XX X X XX XX XX X X X Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Flat Tubular Flat Flat VRLA AGM VRLA AGM VRLA AGM VRLA AGM VRLA AGM VRLA AGM VRLA AGM VRLA AGM VRLA GEL VRLA GEL VRLA GEL VRLA GEL VRLA GEL VRLA GEL VRLA Lead Carbon X X X X X X X X X X X X X X X General Purpose >20Ah:10 20Ah:5 X X X X X X X Long Life Long Life Very Long life Long life 10 2V:15 6V/V:10 Very Long life Long life 18 15 10 (35 ) 10 10 10 Very Long life 2V:18 V: 2V:20 6V/V:15 6.5-245C20 42-250C10 55-190C10 80-3000C10 105-560C10 800-2000C10 400-3000C10 80-1000C10 38-200C20 40-235C10 100-150C20 65-200C10 33-00C10 50-3000C10 Very Long life VRLA AGM General Purpose 15 5 500/1000 C10 70-285C5 Number of Cycles (IEC60896-21/22) 270 260 350 600 500 630 630 2V:800 V:400 350 700 500 600 1000 1500 3500 600 06 07

SP SP Battery Capacity C20 1.75V/cell L W H TH Short Circuit SSP-6.5 6.5 151 65.5 94 99 2.05 170 27 SP-03 SSP-7 7 151 65.5 94 99 2.15 190 23 SP-03 SSP-8 8 151 65.5 94 99 2.35 210 19 SP-03 SSP-9HR 9 151 65.5 94 99 2.62 230 14 SP-03 SSP- 151 98.5 95.5 101.5 3.6 310 14 SP-03 SSP-18 18 181 76.5 167 167 5.30 460 15 SP-11 SP-26( R ) 26 164.5 175 7 7 8.0 670 8.5 M6 Φ14 SP-26( F ) 26 164.5 175 7 7 8.0 670 8.5 SP-11 SP-33 33 195 130 158 163 10.5 850 10.2 M6 Φ14 Design life: >20Ah,10 years; 20Ah, 5 years (25 ) EUROBAT Classification: General Purpose (>20Ah) and Standard Commercial ( 20Ah) High gas recombination efficiency Easy handling Easy installation: vertical or horizontal UPS units Emergency power; Generators starting; EPS units IEC61056-1/2:2002 GB/T 19639.1-2014 JIS C8702-1/2:2009 Positive plates Flat pasted plate with lead-calcium-tin grid alloy SP-38 38 196 165 165 170.0 1310 9.0 M6 Φ16 SP-42 42 196 165 165 170.9 1400 8.5 M6 Φ16 SP-50 50 257 132 193 198 16.1 1600 7.2 M6 Φ16 SP-65 65 314 166 169 174 20.2 1700 6.0 M6 Φ16 SP-80 80 350 167 179.5 179.5 23.2 2600 5.0 M6 Φ16 SP-100 100 330 174 217 226 29.8 3000 4.2 M8 Φ18 SP-0 0 375 174 219 227 34.8 3300 3.5 M8 Φ18 SP-150 150 483 171 219 227 42.5 3650 2.9 M8 Φ18 SP-200 200 522 234 218 223 59.0 3900 2.8 M8 Φ18 SP-245 245 534 271 225 233 71.5 4600 2.4 M8 Φ18 Negative plates Container and Lid posts Posts sealing Flat pasted plate with lead-calcium grid alloy Microporous AGM separator High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid High-conductivity terminals with threaded inserts Double sealing structure High-efficiency low pressure venting system Note: 1. resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. 2.For designation in Table: HR= High Discharge Power Rate 08 09

SPG SPG Battery ADVANTAGES MAIN APPLICATIONS Capacity C10 1.80V/cell W/pc 15 min at 1.67V /cell L W H TH Short Circuit SPG-175W 42 175 196 165 165 170 13.9 1600 7.50 M6 Φ16 SPG-215W 55 215 228 138 209 214 17.2 1850 6.40 M6 Φ16 SPG-255W 70 255 261 171 209 217 22.5 2050 5.80 M6 Φ16 SPG-320W 75 320 261 171 209 217 25.5 2650 4.45 M6 Φ16 SPG-300W 80 300 350 167 179.5 179.5 24.6 2400 5.00 M6 Φ16 SPG-340W 90 340 306 171 209 217 27.4 2450 4.90 M6 Φ16 SPG-390W 100 390 330 174 217 226 31.6 3150 3.80 M8 Φ18 SPG-440W 115 440 375 174 219 227 36.2 3200 3.70 M8 Φ18 SPG-490W 135 490 345 172 275 280 42.5 3300 3.60 M8 Φ18 SPG-500W 140 500 483 171 219 227 43.0 3750 3.20 M8 Φ18 STANDARDS REF. SPG-570W 145 570 483 171 219 227 45.6 4350 2.75 M8 Φ18 SPG-660W 180 660 497 203 228 237 58.0 4800 2.47 M8 Φ18 SPG-700W 200 700 522 234 218 225 63.2 4900 2.45 M8 Φ18 SPG-770W 210 770 522 234 218 225 66.3 5700 2.10 M8 Φ18 SPG-870W 250 870 534 271 225 233 77.9 6100 1.95 M8 Φ18 Design life: 10 years + (25 ) UPS units IEC60896-21/22: 2004 EUROBAT Classification: Long life Data Center; GB/T 19639.1-2005 High Power and High Energy Density Generators starting; JIS C8702-1/2:2009 EPS units High gas recombination efficiency Easy handling Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is Easy installation: vertical or horizontal HIOKI-3551 made by Hioki in Japan. 10 Positive plates Flat pasted plate with lead-calcium-tin grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy Microporous AGM separator Container and Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure High-efficiency low pressure venting system 11

FT FT Capacity C10 1.80V/cell L W H Short Circuit FTB-55 55 277 106 222.5 17 14 8.5 FT-51 FTB-80 80 395 110 288 26.0 2300 5.2 FT-52 FTB-95 95 395 105 270 28.5 2500 4.8 FT-54 FTB-100 100 395 110 288 32.0 2720 4.5 FT-57 FTB-105 105 508 110 238 34.2 2920 4.1 FT-54 FTB-5 5 551 110 288 38.5 3000 4 FT-53 FTB-150 150 551 110 288 45.0 3200 3.6 FT-57 FTA-100 100 558 5 230 36.3 2650 4.8 FT-55 FTA-5 5 558 5 270 45.2 3000 4 FT-55 Design life: years (25 ) EUROBAT Classification: Long life High discharge performance High gas recombination efficiency Easy installation and handling Centralized venting system Telecommunications Emergency power UPS Electrical Power plants and substation Transportation IEC60896-21/22: 2004 BS 6290-4:1997 YD/T2343-2011 FTA-150 150 558 5 311 52.7 3200 3.6 FT-55 FTA-175 175 558 5 311 54.0 3650 3.3 FT-55 FTA-190 190 546 5 324 58.0 3750 4.1 FT-55 FTA-200 200 546 5 324 59.0 3800 4.0 FT-55 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Positive plates Negative plates Container and lid posts Posts sealing Plates suspension Inter-cell connectors hardware Thick flat pasted plate with lead-calcium-tin grid alloy Flat pasted plate with lead-calcium grid alloy Microporous AGM separator High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid High-conductivity terminals with threaded inserts Double sealing structure High-efficiency low pressure venting system Bottom supported Insulated rigid copper Stainless steel + Plastic cover 13

GFM-C GFM-C Capacity C10 1.80V/cell L W H TH Short Circuit GFM-200C 2 200 89.5 179.0 367 377 13.4 3100 0.75 M8 Φ20 GFM-300C 2 300 2.5 179.0 367 377 18.5 3900 0.58 M8 Φ20 GFM-400C 2 400 155.5 179.0 367 377 24.0 4900 0.43 M8 Φ20 GFM-500C 2 500 188.5 179.0 367 377 29.0 5200 0.40 M8 Φ20 GFM-600C 2 600 222.5 180.0 367 377 34.5 5600 0.35 M8 Φ20 GFM-800C 2 800 289.5 180.0 367.5 367.5 46.0 7200 0.34 M8 Φ20 GFM-1000C 2 1000 369.0 180.0 367.5 367.5 58.5 8600 0.38 M8 Φ20 GFM-00C 2 00 510.0 175.0 338.0 347.0 71.5 9000 0.18 M8 Φ18 GFM-1500C 2 1500 318.0 341.0 341.0 351.0 86.5 11500 0.18 M8 Φ18 Design life: 2V series: 15 years, V series: 10 years (25 ) EUROBAT Classification: 2V series: Very long life, V series: Long life High discharge performance 99%+ gas recombination efficiency Horizontal installation for 2V1000Ah and below batteries Telecommunications; Emergency power; UPS units; Electrical Power plants and substation Transportation GB/T19638.2-2014 YD/T 799-2010 DL/T 637-1997 JIS C8704-1:2006 JIS C8704-2:2006 IEC60896-21/22:2004 Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy Microporous AGM separator Container and Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure Patent labyrinth type, two-layer and explosion-proof acid filter valve Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel + Plastic cover GFM-2000C 2 2000 433.0 342.0 341.0 351.0 118.0 13400 0.10 M8 Φ18 GFM-3000C 2 3000 629.0 346.0 341.0 351.0 174.0 20000 0.09 M8 Φ18 6GFM-38 38 196 165 165 170.7 1450 8.10 M6 Φ16 6GFM-50 50 258 168 169 177 16.6 1750 6.80 M6 Φ16 6GFM-65 65 314 166 169 174 20.6 2100 5.60 M6 Φ16 6GFM-80 80 261 171 209 217 24.4 2350 5.10 M6 Φ16 6GFM-100 100 330 174 217 226 30.0 2400 5.00 M8 Φ18 6GFM-150 150 483 171 219 227 44.7 3750 3.20 M8 Φ18 6GFM-200 200 522 234 218 227 60.0 3850 3.10 M8 Φ18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. 14 15

GFMG GFMG Capacity C10 1.80V/cell L W H TH Short Circuit GFMG-200 2 200 110 208 242 260 13.5 3200 0.58 M8 Φ18 GFMG-275 2 275 142 205 242 260 18.1 3600 0.52 M8 Φ18 GFMG-300 2 300 142 205 242 260 18.6 4100 0.48 M8 Φ18 GFMG-320 2 320 195 206 220 240 22.8 4500 0.47 M8 Φ18 GFMG-400 2 400 195 208 253 258 25.6 5100 0.42 M8 Φ18 GFMG-455 2 455 296 203 222 240 32.6 5200 0.4 M8 Φ18 GFMG-515 2 515 296 203 222 240 34.7 5400 0.38 M8 Φ18 GFMG-560 2 560 296 203 222 240 36.1 5700 0.36 M8 Φ18 Design life: years (25 ) EUROBAT Classification: Long life High discharge performance 99%+ gas recombination efficiency Easy installation and handling Telecommunications Emergency power UPS units Electrical Power plants and substation Transportation GB/T19638.2-2014 IEC60896-21/22:2004 3GFMG-105 6 105 195 206 220 240 22.4 2400 2.62 M8 Φ18 3GFMG-5 6 5 278 178 238 258 25.5 2300 2.63 M8 Φ18 3GFMG-160 6 160 278 178 238 258 30.6 2580 2.35 M8 Φ18 3GFMG-200 6 200 250.5 5.5 362 365 33.7 3800 1.55 M8 Φ18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy Microporous AGM separator Container and Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure Patent labyrinth type, two-layer and explosion-proof acid filter valve Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel + Plastic cover 16 17

GFM-H GFM-H Capacity C10 1.80V/cell L W H Short Circuit 4GFM-800H 8 800 615 780 295.5 238.3 6000 0.36 M8 Φ20 3GFM-1000H 6 1000 615 835 258.0 218.1 7500 0.31 M8 Φ20 3GFM-00H 6 00 615 835 294.5 256.9 8700 0.22 M8 Φ20 2GFM-1500H 4 1500 615 705 295.5 215.1 11000 0.20 M8 Φ20 2GFM-2000H 4 2000 615 855 299.0 270.6 13000 0.28 M8 Φ20 Design life: 15 years (25 ) EUROBAT Classification: Very long life High discharge performance 99%+ gas recombination efficiency Module structure design Telecommunications UPS units Electrical Power plants and substation GB/T19638.2-2014 YD/T 799-2010 DL/T 637-1997 IEC60896-21/22:2004 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Horizontal installation Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy Negative plates Container and Lid posts Posts sealing Plates suspension Inter-cell connectors Flat pasted plate with lead-calcium grid alloy Microporous AGM separator High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid High-conductivity terminals with threaded inserts Double sealing structure Patent labyrinth type, two-layer and explosion-proof acid filter valve Bottom supported Insulated flexible cable 18 19

GFMU-C GFMU-C 10hr 1.80Vpc Capacity 20hr 1.85Vpc 0hr 1.85Vpc L W H TH Short Circuit GFMU-200C 2 200 206 240 89.5 179.0 367 377 13.4 3100 0.75 M8 Φ20 GFMU-300C 2 300 308 360 2.5 179.0 367 377 18.5 3900 0.58 M8 Φ20 GFMU-400C 2 400 4 480 155.5 179.0 367 377 24.0 4900 0.43 M8 Φ20 GFMU-500C 2 500 514 600 188.5 179.0 367 377 29.0 5200 0.40 M8 Φ20 GFMU-600C 2 600 618 720 222.5 180.0 367 377 34.5 5600 0.35 M8 Φ20 GFMU-800C 2 800 824 960 289.5 180.0 367.5 367.5 46.0 7200 0.34 M8 Φ20 GFMU-1000C 2 1000 1028 00 369.0 180.0 367.5 367.5 58.5 8600 0.38 M8 Φ20 GFMU-00C 2 00 08 1440 510 175 338 347 71.5 9000 0.18 M8 Φ18 Design life: 15 years (25 ) EUROBAT Classification: Very long life High discharge performance 99%+ gas recombination efficiency Horizontal installation for 2V1000Ah and below Solar (Wind) energy storage system Solar communication/station Mobile storage system GB/T19638.2-2014 JIS C8704-1:2006 JIS C8704-2:2006 IEC61427-2014 installation compliant with GFMU-1500C 2 1500 1510 1800 318 341 341 351 86.5 11500 0.18 M8 Φ18 GFMU-2000C 2 2000 2020 2400 433 342 341 351 118.0 13400 0.10 M8 Φ18 GFMU-3000C 2 3000 3020 3600 629 346 341 351 174.0 20000 0.09 M8 Φ18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. batteries Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy Microporous AGM separator Container High-strength ABS (option: available in Flame Retardant UL94 V0 version) Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure Patent labyrinth type, two-layer and explosion-proof acid filter valve Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel+ Plastic cover 20 21

HTB HTB Capacity C 10 1.80V/cell L W H TH Short Circuit GFM-200HT 2 200 118 176 337 347 16.4 2500 0.34 M8 Φ20 GFM-300HT 2 300 154 176 337 347 21.5 3900 0.34 M8 Φ20 GFM-400HT 2 400 201 177 337 347 29.0 5000 0.30 M8 Φ20 GFM-500HT 2 500 248 177 337 347 35.5 5500 0.28 M8 Φ20 GFM-600HT 2 600 296 178 337 347 43.0 6600 0.35 M8 Φ20 GFM-800HT 2 800 390 177 337 347 57.0 10000 0.15 M8 Φ20 GFM-1000HT 2 1000 484 177 337 347 71.0 11000 0.14 M8 Φ20 FTB-80HT 80 395 105 270 270 28.5 2500 4.8 FT-54 FTA-100HT 100 558 5 230 230 37.5 2500 4.8 FT-55 Design life: 2V series: 20 years, V series: 15 years at (25 ) EUROBAT Classification: Very long life Specifically designed for semi-stable mains High discharge performance 99%+ gas recombination efficiency Horizontal installation for 2V batteries Centralized venting system for V batteries High temperature BTS Unstable grid BTS Remote area BTS Solar (Wind) energy storage system GB/T22473-2008 JIS C8704-1:2006 JIS C8704-2:2006 IEC60896-21/22:2004 IEC61427-2014 FTA-150HT 150 558 5 311 311 52.7 3200 3.6 FT-55 FTA-190HT 190 546 5 324 324 59.0 3750 4.0 FT-55 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Positive plates Thick flat pasted plate with special lead-tin polybasic grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy Microporous super thin AGM separator Container High-strength & heat resistance ABS (option: available in Flame Retardant UL94 V0 version) Lid High-strength & heat resistance ABS (option: available in Flame Retardant UL94 V0 version) Absorbed low density sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure Patent labyrinth type, two-layer and explosion-proof acid filter valve Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel+ Plastic cover 22 23

SAJ SAJ 10hr 1.80Vpc Capacity 20hr 1.80Vpc 0hr 1.85Vpc L W H TH Short Circuit SAJ-38 35.3 38 40.8 196 165 165 170.0 1300 9.1 M6 16 SAJ-42 39.1 42 47.0 196 165 165 170.9 1400 8.6 M6 16 SAJ-50 46.5 50 55.2 257 132 193 198 16.1 1480 8.1 M6 16 SAJ-65 60.4 65 79.2 314 166 169 174 20.2 1700 7.1 M6 16 SAJ-80 74.4 80 92.4 350 167 179 179 23.2 2600 4.6 M6 16 SAJ-100 93 100 109.2 330 174 217 226 29.8 2800 4.2 M8 18 Design life: 10 years (25 ) EUROBAT Classification: Long life High gas recombination efficiency Easy handling Easy installation: vertical or horizontal Solar (Wind) energy system Solar communication/station Mobile storage system IEC 60896-21/22:2004 DIN 43539-T5 JIS C8702-1/2:2009 SAJ-150A 139.5 150 166.8 483 171 219 227 42.5 3720 3.2 M8 18 SAJ-200A 186 200 224.4 522 234 218 225 58.0 3960 3.0 M8 18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan Positive plates Flat pasted plate with lead-calcium-tin grid alloy Negative plates Container and Lid posts Posts sealing Flat pasted plate with lead-calcium grid alloy Microporous AGM separator High-strength ABS (option: available in Flame Retardant UL94 V0 version) Gel: SiO2 gelled sulfuric acid High-conductivity terminals with threaded inserts Double sealing structure High-efficiency low pressure venting system 24 25

SDC SDC Battery Capacity C10 1.75V/cell C5 1.75V/cell L W H TH Maximum Discharge 25 in 1min in 1sec 25 mohm SDC-43 43 39.5 196 165 165 170 14.0 180 360 6.0 M6 Φ16 SDC-75 75 70 261 168 2 216 24.0 300 1100 7.0 M6 Φ16 SDC -90 91 85 261 168 2 216 26.5 400 1320 6.0 M6 Φ16 SDC-110 113 110 330 175 215 224 35.0 500 1650 5.0 M8 Φ18 SDC-135 135 5 406 172 216 221 41.0 600 2100 4.0 M8 Φ18 SDC-170 173 165 482 170 236 236 52.0 740 2430 3.8 M8 Φ20 Deep cycle for solar application Good large current discharge performance High gas recombination efficiency Easy installation and handling Renewable energy universal IEC60896-21/22:2004 IEC61427-2014 SDC6-195 6 195 185 261 180 245 252 30.0 850 2620 2.5 M8 Φ20 SDC6-235 6 235 220 261 180 270 273 35.0 1000 3000 2.0 M8 Φ20 SDC6-235B 6 235 220 330 180 222 222 36.0 1000 3000 2.0 M8 Φ20 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan Positive plates Flat plate with lead-calcium-tin grid alloy Negative plates Container and Lid posts Posts sealing Plates suspension Flat pasted plate with lead-calcium grid alloy(radial design) Microporous AGM separator High-strength opaque ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid High-conductivity terminals Double sealing structure High-efficiency low pressure venting system Bottom supported 26 27

FTJ FTJ Capacity C10 1.80V/cell C20 1.75V/cell L W H Short Circuit 6FTJ-100A 100 107 558 5 230 36.3 2100 4.80 FT-55 6FTJ-100B 90 100 395 110 288 33.8 2100 5.50 FT-57 6FTJ-5A 5 133.6 558 5 270 45.7 2500 4.37 FT-55 6FTJ-150B 135 142 551 110 288 45.0 2700 4.33 FT-57 6FTJ-150A 150 160.4 546 5 311 53.7 3000 4.33 FT-55 Design life: years (25 ) EUROBAT Classification: Long life High discharge performance High fast charge performance High gas recombination efficiency Easy installation and handling Centralized venting system Shelf Life24 months Telecommunications Emergency power UPS units Electrical Power plants and substation Transportation IEC60896-21/22: 2004 DIN43539-T5 1984 YD/T1360-2005 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy (radial design) Negative plates Flat pasted plate with lead-calcium grid alloy(radial design) Microporous PVC-SiO2 separator Container and lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Gel: SiO2 gelled sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure One way valve with integrated flame arrestor Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel+ Plastic cover 28 29

FMJ FMJ Capacity 10hr 20hr 1.80Vpc 1.85Vpc 0hr 1.85Vpc L W H TH Short Circuit 6FMJ-65 65 66.2 84 310 174 209 236 27 1540 7.25 M8 Φ16 6FMJ-85 85 86.6 109.2 414 174 218 228 34 2060 5.19 M8 Φ16 6FMJ-100 100 102 8.4 513 163 218 228 40 2950 3.91 M8 Φ16 6FMJ-0 0 2.4 153.6 513 232 218 228 47 2980 3.66 M8 Φ16 6FMJ-150 150 152.8 193.2 513 232 218 228 59 3020 3.55 M8 Φ16 6FMJ-200 200 208 261.6 513 296.5 218 228 75.5 3050 3.11 M8 Φ16 Design life: 10 +years (25 ) EUROBAT Classification: Long life High discharge performance High gas recombination efficiency Easy installation and handling Shelf life: 24 months (25 ) Telecommunications; Emergency power; Renewable Energy storage systems UPS units; Electrical Power plants and substation Transportation IEC60896-21/22: 2004 DIN43539-T5 1984 IEC61427-2005 YD/T1360-2005 GB/T 22473-2008 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. Positive plates Thick flat pasted plate with lead-calcium-tin grid alloy (radial design) Negative plates Flat pasted plate with lead-calcium grid alloy(radial design) Microporous PVC-SiO2 separator Container and Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Gel: SiO2 gelled sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure One way valve with integrated flame arrestor Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel+ Plastic cover 30 31

GFMJ GFMJ Capacity C10 1.80V/cell L W H TH Short Circuit 6GFMJ-33 33 198 166 170 170 14 1010 8.5 M6 Φ16 6GFMJ-50 50 276 174 169 198 21 1525 7.64 M8 Φ16 6GFMJ-65 65 310 174 209 236 30 1540 7.35 M8 Φ16 6GFMJ-85 85 414 174 218 228 37 2060 5.85 M8 Φ16 6GFMJ-100 100 513 163 218 228 44 2950 3.91 M8 Φ16 6GFMJ-0 0 513 232 218 228 52.3 2980 3.86 M8 Φ16 6GFMJ-150 150 513 232 218 228 63.8 3020 3.65 M8 Φ16 Design life: 2V series: 15 years, V series: years (25 ) EUROBAT Classification: 2V series: Very long life; V series: Long life High discharge performance High gas recombination efficiency Easy installation and handling Shelf life: 24 months (25 ) Telecommunications; Emergency power; Renewable Energy Storage Systems UPS and EPS units; Electrical Power plants and substation Transportation IEC60896-21/22: 2014 DIN43539-T5 1984 IEC61427-2014 YD/T 1360-2014 GB/T 22473-2008 Positive plates Flat pasted plate with lead-calcium-tin grid alloy (radial design) Negative plates Flat pasted plate with lead-calcium grid alloy(radial design) Microporous PVC-SiO2 separator Container and Lid High-strength ABS (option: available in Flame Retardant UL94 V0 version) Gel: SiO2 gelled sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure One way valve with integrated flame arrestor Plates suspension Bottom supported Inter-cell connectors Insulated rigid copper hardware Stainless steel+ Plastic cover 6GFMJ-200 200 513 296.5 218 228 82.8 3050 3.2 M8 Φ16 GFMJ-200 2 200 171 107 334 344 14.8 2800 0.68 M8 Φ18 GFMJ-300 2 300 171 151 334 344 21.3 3600 0.54 M8 Φ18 GFMJ-400 2 400 211 175 334 344 30 4350 0.45 M8 Φ18 GFMJ-500 2 500 243 174 334 344 35.5 5020 0.39 M8 Φ18 GFMJ-600 2 600 302 177 334 344 44 5860 0.33 M8 Φ18 GFMJ-800 2 800 410 175 334 344 60 6900 0.28 M8 Φ18 GFMJ-1000 2 1000 478 175 334 344 71 8000 0.24 M8 Φ18 GFMJ-00 2 00 346 310 335 357 85.5 9600 0.165 M8 Φ18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan. 32 33

OPZV OPZV Capacity C10 1.80V/cell L W H TH Short Circuit 3 OPzV 150 2 150 103 206 352.5 385 15.0 1500 0.80 M10 Φ20 4 OPzV 200 2 200 103 206 352.5 385 17.4 2000 0.75 M10 Φ20 5 OPzV 250 2 250 4 206 352.5 385 21.1 2500 0.70 M10 Φ20 6 OpzV 300 2 300 145 206 352.5 385 24.7 2999 0.60 M10 Φ20 5OPzV 350 2 350 4 206 471 503.5 27.5 3049 0.58 M10 Φ20 6 OPzV 420 2 420 145 206 471 503.5 32.4 3658 0.55 M10 Φ20 7 OPzV 490 2 490 166 206 471 503.5 37.3 4268 0.50 M10 Φ20 7 OPzV 500 2 500 166 206 471 503.5 37.3 4268 0.50 M10 Φ20 Design life: 2V series:18 years, 6V/V series:15 years (25 ) Electrical Power plants and substation IEC60896-21/22: 2004 IEC61427-2014 EUROBAT Classification: Very long life DIN43539-T5 1984 Telecommunications Up to 1500 deep discharge cycles at 80% DOD DIN40742:1999 Renewable Energy Storage High discharge performance BSEN 61427-2002 High gas recombination efficiency Systems Emergency power YD/T1360-2005 GB/T 22473-2008 UPS and EPS units; Easy installation: vertical or horizontal for 2V Transportation series, vertical for 6V/V series Shelf life: 24 months (25 ) Positive plates Tubular plate with lead-calcium-tin grid alloy Negative plates Flat pasted plate with lead-calcium grid alloy(radial design) Microporous PVC-SiO2 separator Container and Lid High-strength opaque ABS (option: available in Flame Retardant UL94 V0 version) Gel: SiO2 gelled sulfuric acid posts High-conductivity terminals with threaded inserts Posts sealing Double sealing structure One way valve with integrated flame arrestor Plates suspension Bottom supported Inter-cell connectors Fully Insulated copper hardware Fully insulate steel adaptor Solid lead plated copper plates 6 OPzV 600 2 600 145 206 646 678.5 45.7 4606 0.45 M10 Φ20 8 OPzV 800 2 800 191 210 646 678.5 60.8 6141 0.40 M10 Φ20 10 OPzV 1000 2 1000 233 210 646 678.5 74.5 7676 0.35 M10 Φ20 OPzV 00 2 00 275 210 646 678.5 88.8 9211 0.30 M10 Φ20 15 OPzV 1500 2 1500 340 210 646 678.5 110.5 11514 0.24 M10 Φ20 16 OPzV 2000 2 2000 399 2 772 804 150.0 657 0.22 M10 Φ24 20 OPzV 2500 2 2500 487 2 772 804 181.0 15821 0.17 M10 Φ24 24 OPzV 3000 2 3000 576 2 772 804 219.5 18986 0. M10 Φ24 V 1 OPzV 50 50 272 205 335 365 33.5 500 13 M6 Φ18 V 2 OPzV 100 100 272 205 335 365 51.5 1000 7.2 M6 Φ18 V 3 OPzV 150 150 380 205 335 365 71.3 1500 6.2 M6 Φ18 6V 4 OPzV 200 6 200 272 205 335 365 47.5 2000 1.95 M6 Φ18 6V 5 OPzV 250 6 250 380 205 335 365 59.0 2500 1.70 M6 Φ18 6V 6 OPzV 300 6 300 380 205 335 365 68.05 3000 1.50 M6 Φ18 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan 34 35

FCP FCP PRODUCT FEATURES The Technology From Furukawa Battery Technology transferred from Furukawa battery company and produced by us with quality control by Furukawa Battery, targeting for energy storage applications. Super Long Cycle Life Using long-life technology and design, more than 4200 cycles at 70%DOD, design life is 15 years plus. Leading Lead Carbon Technology Using lead carbon technology, improve the charge acceptance ability, reduce the cathode sulphation, more suitable for the partial state of charge (PSOC) applications. Advanced Manufacturing Technology Advanced production control and strict process, ensuring the consistence and reliability of the products. Modular System Design Modular design and installation, compact structure, saving the installation area and space, easy installation, convenient maintenance. This series is original products of Furukawa battery, the earliest commercialized lead carbon VRLA battery in the world. Since the technology was transferred to us, we have successfully implemented the exact same production in our facilities. ly we are the first and unique battery manufacturer possessing the overall ability of manufacturing real sense, worldwide first class lead carbon battery in China. MAIN PARAMETERS TABLE STANDARDS Capacity C 10 1.80V/cell L W H IEC61427-2014 BS 6290-4:1997 YD/T 799-2010 FCP-500 2 500 166 172 508 41.0 0.3 M10 FCP-1000 2 1000 303 172 508 75.0 0.2 M10 Passed ISO9001, ISO14001, OHSAS18001, UL and CE certification. 36 37

PzS/PzB PzS/PzB PzS Battery PRODUCT DESIGN 1 Container and lid Container and lid is PP material, based on the heat sealing technology to avoid leak of the electrolyte. 2 Negative plate Thick with cage design for improved holding of the active material and high electrical conductivity. 3 Separator Microporous polyethylene envelops, to ensure high performance and complete insulation between positive and negative plates, while allowing the free flow of electrolyte throughout the cell. 4 Positive plate Matured tubular positive plate technology, use imported non-woven calandria in all plate calandria. 5 Positive and negative terminal with large copper core cast lead alloy to ensure the battery large current discharge performance. Battery capacity and discharge rate in 5 hours capacity and discharge rate in 6 hours Maximum Dimension (mm) Capacity Capacity Length Width Height with (±5% Kg) 2PzS160 160 32 168 28 47 198 435 9.8 3PzS240 240 48 252 42 65 198 435 14.0 4PzS320 320 64 336 56 83 198 435 18.1 5PzS400 400 80 420 70 101 198 435 22.6 6PzS480 480 96 504 84 119 198 435 26.6 7PzS560 560 1 588 98 137 198 435 31.1 8PzS640 640 8 672 1 155 198 435 35.2 9PzS720 720 144 756 6 174 198 435 42.1 10PzS800 800 160 840 140 192 198 435 46.8 6 7 Safety valve Unique mist collection reflux design, reduces water loss, and reduces maintenance frequency. Flexible connector With copper core to avoid loose caused by vibration and facilitate maintenance. Holes reserved on the protection cover of the connector for testing the battery voltage. 2PzS230 230 46 242 40.3 47 198 575 13.6 3PzS345 345 69 362 60.3 65 198 575 19.4 4PzS460 460 92 483 80.5 83 198 575 25.2 5PzS575 575 115 604 100.6 101 198 575 31.1 6PzS690 690 138 725 0.8 119 198 575 36.9 7PzS805 805 161 845 140.8 137 198 575 42.7 8PzS920 920 184 966 161 155 198 575 48.6 9PzS1035 1035 207 1087 181.2 174 198 575 54.3 10PzS1150 1150 230 08 201.3 192 198 575 60.2 2PzS250 250 50 263 43.8 47 198 600 14.3 3PzS375 375 75 394 65.7 65 198 600 20.5 4PzS500 500 100 525 87.5 83 198 600 26.9 5PzS625 625 5 656 109.3 101 198 600 32.9 6PzS750 750 150 788 131.3 119 198 600 39.4 7PzS875 875 175 920 153.3 137 198 600 45.8 8PzS1000 1000 200 1050 175 155 198 600 51.5 9PzS15 15 225 1181 196.8 174 198 600 57.7 10PzS50 50 250 1313 218.8 192 198 600 64.0 2PzS280 280 56 294 49 47 198 715 19.1 3PzS420 420 84 441 73.5 65 198 715 25.4 4PzS560 560 1 588 98 83 198 715 32.9 38 39

PzS/PzB PzS/PzB PzS Battery Battery PzB Battery Battery capacity and discharge rate in 5 hours capacity and discharge rate in 5 hours capacity and discharge rate in 6 hours capacity and discharge rate in 6 hours Maximum Dimension (mm) Capacity Capacity Length Width Height Maximum Dimension (mm) Capacity Capacity Length Width Height with (±5% Kg) 5PzS700 700 140 735 2.5 101 198 715 39.9 6PzS840 840 168 882 147 119 198 715 47.2 7PzS980 980 196 1029 171.5 137 198 715 54.8 8PzS10 10 224 1176 196 155 198 715 62.3 9PzS60 60 252 1323 220.5 174 198 715 71.0 10PzS1400 1400 280 1470 245 192 198 715 76.7 2PzS310 310 62 326 54.3 47 198 750 19.1 3PzS465 465 93 488 81.3 65 198 750 25.6 4PzS620 620 4 651 108.5 83 198 750 33.6 5PzS775 775 155 814 135.7 101 198 750 42.1 6PzS930 930 186 977 162.8 119 198 750 50.1 7PzS1085 1085 217 1140 190 137 198 750 58.2 8PzS40 40 248 1320 220 155 198 750 66.3 9PzS1395 1395 279 1465 244.2 174 198 750 74.5 10PzS1550 1550 310 1628 271.3 192 198 750 81.3 with (±5% Kg) 2PzB110 110 22 116 19.5 45 157.5 428 8.4 3PzB165 165 33 174 28.9 61 157.5 428 11.5 4PzB220 220 44 231 38.5 77 157.5 428 14.6 5PzB275 275 55 289 48.1 93 157.5 428 17.8 6PzB330 330 66 347 57.8 109 157.5 428 20.9 7PzB385 385 77 404 67.4 5 157.5 428 24.0 8PzB440 440 88 424 70.7 141 157.5 428 27.2 9PzB495 495 99 520 86.6 157 157.5 428 30.3 10PzB550 550 110 578 96.3 173 157.5 428 33.3 PzB Battery Battery capacity and discharge rate in 5 hours capacity and discharge rate in 6 hours Maximum Dimension (mm) Capacity Capacity Length Width Height with (±5% Kg) 2PzB150 150 30 158 26.3 45 157.5 541 10.9 3PzB225 225 45 236 39.3 61 157.5 541 14.9 4PzB300 300 60 315 52.5 77 157.5 541 19.0 5PzB375 375 75 394 65.7 93 157.5 541 23.1 6PzB450 450 90 473 78.8 109 157.5 541 27.3 7PzB525 525 105 551 91.9 5 157.5 541 31.4 8PzB600 600 0 630 105 141 157.5 541 35.6 9PzB675 675 135 709 118 157 157.5 541 39.5 10PzB750 750 150 788 131.3 173 157.5 541 43.7 11PzB825 825 165 866 144.4 189 157.5 541 47.8 2PzB170 170 34 179 29.8 45 157.5 597.3 3PzB255 255 51 268 44.6 61 157.5 597 17.0 4PzB340 340 68 357 59.5 77 157.5 597 21.6 5PzB425 425 85 446 74.4 93 157.5 597 26.3 6PzB510 510 102 536 89 109 157.5 597 30.9 7PzB595 595 119 625 104 5 157.5 597 35.6 8PzB680 680 136 714 119 141 157.5 597 40.4 9PzB765 765 153 803 133.9 157 157.5 597 44.8 10PzB850 850 170 893 148.8 173 157.5 597 49.7 11PzB935 935 187 982 163.6 189 157.5 597 54.4 2PzB200 200 40 210 35 45 157.5 642.9 3PzB300 300 60 315 52.5 61 157.5 642 17.7 4PzB400 400 80 420 70 77 157.5 642 22.6 5PzB500 500 100 525 87.5 93 157.5 642 27.5 6PzB600 600 0 630 105 109 157.5 642 32.4 7PzB700 700 140 735 2.5 5 157.5 642 37.3 8PzB800 800 160 840 140 141 157.5 642 42.2 9PzB900 900 180 945 157.5 157 157.5 642 46.8 40 41

DM DM Battery Capacity C3 1.75V/cell C5 1.75V/cell L W H TH Maximum Discharge 25 in 1min in 1sec 25 mohm 6-DM-70 60 70 261 168 2 216 24.0 300 1100 7.0 M6 Φ16 6-DM-85 80 85 261 168 2 216 26.5 400 1320 6.0 M6 Φ16 6-DM-110 100 110 330 175 215 224 35.0 500 1650 5.0 M8 Φ18 6-DM-5 0 5 406 172 216 221 41.0 600 2100 4.0 M8 Φ18 6-DM-165 150 165 482 170 236 236 52.0 740 2430 3.8 M8 Φ20 3-DM-185 6 170 185 261 180 245 252 30.0 850 2620 2.5 M8 Φ20 3-DM-220 6 200 220 261 180 270 273 35.0 1000 3000 2.0 M8 Φ20 Up to 700 cycles 80% DOD Good large current discharge performance High gas recombination efficiency Easy installation and handling Electrical Vehicle Hybrid Electrical vehicle GB/T 18332.1-2009 QC/T 742-2006 IEC61982-3 2001-06 GB/T 7403.1-2008 GB/T 23636-2009 3-DM-220C 6 200 220 330 180 222 222 35.5 1000 3000 2.0 M8 Φ20 3-DM-285 6 260 285 356 180 270 270 46.0 1300 3545 1.9 M8 Φ20 4-DM-170 8 150 170 261 180 280 280 36.0 750 2450 3.0 M8 Φ20 Note: resistance is tested in battery fully charged state at 25±5 ambient temperature. The test equipment is HIOKI-3554 made by Hioki in Japan Positive plates Flat plate with lead-calcium-tin grid alloy Negative plates Container and Lid posts Posts sealing Plates suspension Flat pasted plate with lead-calcium grid alloy(radial design) Microporous AGM separator High-strength opaque ABS (option: available in Flame Retardant UL94 V0 version) Absorbed sulfuric acid High-conductivity terminals Double sealing structure High-efficiency low pressure venting system Bottom supported 42 43

International Market We provide one stop power supply solution in Telecom, UPS, Renewable Energy and Motive Power application, with completed and advantaged networks all around the world, to satisfy customers local services and supports at any time. SP-03 SP-11 FT-51 FT-52 FT-53 FT-54 FT -55 FT-56 FT-57 M5xΦ8 M5=5mm Φ8=8mm M5xΦ10 M5=5mm Φ10=10mm M6xΦ M6=6mm Φ=mm M6xΦ13 M6=6mm Φ13=13mm M6xΦ14 M6=6mm Φ14=14mm M6xΦ16 M6=6mm Φ16=16mm M6xΦ18 M6=6mm Φ18=18mm M8xΦ16 M8xΦ17 M8=8mm M8=8mm Φ17=17mm Φ18=18mm SACRED SUN LOCATION M8xΦ18 M8=8mm Φ19=19mm M8xΦ19 M8=8mm Φ20=20mm M8xΦ20 M8=8mm Φ20=20mm M10xΦ20 M10=10mm Φ24=24mm M10xΦ24 M10=10mm Φ10=10mm 44 45